Product Data Sheet

00813-0100-4024, Rev HA
June 2012

Rosemount 5600 Series

Superior Performance Four-Wire


Non-Contacting Radar Level Transmitter
Best performance and uptime provided by
market leading sensitivity
Unique signal processing allows for
challenging process conditions
Extremely reliable and accurate level
transmitter due to its high repeatability
Easy connection with adjustable power
supply, 24-240 Vac/dc, 0-60 Hz
Easy configuration and setup with intelligent
software support
High application flexibility with an extensive
selection of antennas and materials
Minimized maintenance costs with no contact
and no moving parts; no re-calibration
required
Interchangeable transmitter heads and
antennas

Contents
Superior Performance, When Applications Get Tough. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Functional Specification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Performance Specification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Physical Specification. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Product Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Dimensional Drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27

www.rosemount.com

Product Data Sheet

Rosemount 5600 Series

00813-0100-4024, Rev HA
June 2012

Superior Performance, When Applications Get Tough


MEASUREMENT PRINCIPLE
The level of the product in the tank is measured by radar signals transmitted
from the antenna at the tank top. After the radar signal is reflected by the
product surface, the echo is picked up by the antenna. As the signal is
varying in frequency, the echo has a slightly different frequency compared to
the signal transmitted at that moment. The difference in frequency is
proportional to the distance to the product surface, and level can be
accurately calculated. This method is called Frequency Modulated
Continuous Wave (FMCW).
Applications with, for example, turbulence, foam, long measuring ranges,
disturbing objects, and low dielectric constants can reduce the energy
reflecting back and, in worst case, eliminate it completely with the result that
no surface can be detected. The reflection intensity can however be
improved by using a highly sensitive radar, the optimal antenna type, and as
large antenna as possible.

RADAR TECHNOLOGY BENEFITS


Direct level measurement means that virtually no compensation is
needed for changing process conditions (such as density, conductivity,
temperature, pressure, viscosity, pH, dielectric etc.) which results in high
application flexibility
Challenging reactor and mixing
tanks, and tanks with rapid level
changes

Accurate, reliable measurement that requires no re-calibration, meaning


improved uptime
The non-contacting radar transmitter with no moving parts means
minimized maintenance
Good for dirty, coating, crystallizing, and corrosive applications
Top down measurement means simple installation with no empty tank
requirements, and minimized risk for leakages

SPECIAL 5600 FEATURES


For the most challenging applications
4-wire transmitters with maximum sensitivity and performance
Suitable for solids, liquids, and slurries in challenging reactors, with rapid
level changes and excessive process conditions
Low DK solids including lime,
cement, fly ash, corn, and many more

Manages high pressures and temperature


Handles long measuring ranges
Application flexibility with a wide selection of materials, process
connections, antenna styles, and accessories

Cone

Tri- Process
Clamp Seal

Dust
Cover

Parabolic
Antenna

Full range of antenna styles

Product Data Sheet


00813-0100-4024, Rev HA
June 2012

Rosemount 5600 Series

Best Performance and Uptime

The power of 4 wires provides the highest sensitivity and the


ability to detect weak radar echoes in challenging process
environments

Smart EchoLogic with registration of disturbance echoes


provides the ability to handle weak echoes reliably and
identifies the true echo from the clutter

Ability to handle disturbing factors, longer measuring ranges,


and lower dielectrics

Greater measurement reliability margins result in less


downtime, higher safety, and better quality

Robust Design Reduces Costs and Increases Safety

The detachable transmitter head allows the tank to remain


sealed

The dual compartment housing separates cable connections


and electronics, which provides safer handling and improved
moisture protection

Adjustable power supply, 24-240 Vac/dc, 0-60 Hz

Interchangeable transmitter heads and antennas

Allows for easy replacement by standard tank connections

The Smart Wireless


THUM adapter enables
level communication
with previously
inaccessible and remote
tanks

Easy Installation and Plant Integration

Seamless system integration with HART, Modbus, or IEC


62591 (WirelessHART) with the Smart Wireless THUM
adapter

Secondary analog 4-20 mA output

MultiVariable output includes the choice of level, distance,


volume, and signal strength

Pre-configured or easy, user-friendly configuration in


Rosemount RadarMaster with a five-step wizard, auto
connect, and online help

Any DD-compatible configuration tool such as AMS, or Field


Communicator can be used

Fully configurable with the remote- or factory-mounted LOI


Rosemount 2210 with temperature input option

Rosemount 2210
configurable display
with temperature input

Minimized Maintenance Reduces Cost

Non-contacting, no mechanical moving parts that require


maintenance

No re-calibration or compensation needed due to changing


process conditions

The user-friendly software provides easy online


troubleshooting with the echo curve tool, registration of
disturbance echoes, and logging

Predictive maintenance with advanced diagnostics and


PlantWeb alerts

Adjustments without opening the tank

The Rosemount RadarMaster enables easy


configuration and service with a user-friendly
interface including wizards, echo curve with movie
feature, offline/online configuration, extensive
online help, logging capabilities, and much more.

Product Data Sheet

Rosemount 5600 Series

00813-0100-4024, Rev HA
June 2012

Rosemount 5601 Radar Level Transmitter


Rosemount 5601 Radar Level Transmitter is a reliable 4-wire radar level transmitter
designed for outstanding performance in a wide range of applications and process
conditions. Characteristics include:

Handles a wide range of process conditions

Extensive selection of antennas and materials

HART 4-20 mA, Modbus, or IEC 62591 (WirelessHART) with the Smart Wireless THUM
adapter

Additional Information
Specifications: page 13
Product Certifications: page 23
Dimensional Drawings: page 27

Ordering
Information

TABLE 1. Rosemount 5601 Radar Level Transmitter Ordering Information

The Standard offering represents the most common options. The starred options () should be selected for best delivery.
The Expanded offering is subject to additional delivery lead time.
Model

Product Description

5601

Radar Level Transmitter for Process Applications

Frequency Band
Standard
U
S
A

Standard
US Market Only (10 GHz)
Switzerland Market Only (10 GHz)
All Other Markets (10 GHz)

Product Certification
Standard
NA
E1
E5
E6
E7

Standard
None
CENELEC/ATEX Flameproof
FM Explosion-proof
CSA Explosion-proof
IECEx Flameproof

24-240 Vdc/ac 0-60 Hz

Power Supply
Standard
P

Primary Output
Standard
5A
5B
5C
5D
8A

Standard
4-20 mA with HART communication, Passive Output
4-20 mA with HART communication, Passive Output, Intrinsically Safe Circuit (1)
4-20 mA with HART communication, Active Output
4-20 mA with HART communication, Active Output, Intrinsically Safe Circuit (1)
RS 485 Protocol - Modbus

Secondary Output(2)(3)
Standard
0
1(4)
2(4)
3
4

Standard
None
4-20 mA, Passive Output (5)
4-20 mA, Passive Output, Intrinsically Safe Circuit (1)
4-20 mA, Active Output (5)
4-20 mA, Active Output, Intrinsically Safe Circuit (1)

Product Data Sheet


00813-0100-4024, Rev HA
June 2012

Rosemount 5600 Series

TABLE 1. Rosemount 5601 Radar Level Transmitter Ordering Information

The Standard offering represents the most common options. The starred options () should be selected for best delivery.
The Expanded offering is subject to additional delivery lead time.
Display Unit
Standard
N
P
R
T

Standard
None
LOI, Factory mounted on transmitter
LOI, Remote mounted
LOI, Remote mounted with temp inputs (1-6 spot elements with common returns)

Volume Calculation
Standard
E
V

Standard
Basic Volume Equations (Standard)
Strapping Table, up to 100 points

Typical Model Number: 5601 S E1 P 5A 0 P E Antenna Selection (6)


(1)
(2)
(3)
(4)
(5)
(6)

Intrinsically safe circuit only applicable if product certificate codes E1, E5, E6, or E7 is selected.
Secondary output codes are not available in a combination of E6 CSA and Primary Output codes 5A, 5B, 5C, or 5D.
Secondary output codes 1, 2, 3, and 4 require an isolator when used in combination with 7A, 7B, or 8A.
Not available in combination with Primary Output codes 5A, 5B, 5C, or 5D.
Not allowed in combination with Display Unit codes P, R, or T.
Select the antenna type and options using Table 2, Table 3, Table 4, Table 6, and Table .

Product Data Sheet


00813-0100-4024, Rev HA
June 2012

Rosemount 5600 Series


TABLE 2. Cone Antenna Ordering Information

The Standard offering represents the most common options. The starred options () should be selected for best delivery.
The Expanded offering is subject to additional delivery lead time.
Antenna Type Antenna Size

Antenna Material

Note

3 in. (DN80) nozzles


4 in. (DN100) nozzles
6 in. (DN150) nozzles
8 in. (DN200) nozzles

SST 316L
SST 316L
SST 316L
SST 316L

Pipe Installation Only


Free propagation or 4 pipe
Free propagation or 6 pipe
Free propagation only

10 in. (DN250) nozzles


3 in. (DN80) nozzles
4 in. (DN100) nozzles
6 in. (DN150) nozzles
8 in. (DN200) nozzles
3 in. (DN80) nozzles
4 in. (DN100) nozzles
6 in. (DN150) nozzles
8 in. (DN200) nozzles
3 in. (DN80) nozzles
4 in. (DN100) nozzles
6 in. (DN150) nozzles
8 in. (DN200) nozzles
3 in. (DN80) nozzles
4 in. (DN100) nozzles
6 in. (DN150) nozzles
8 in. (DN200) nozzles
Customer specific cone or material

SST 316L
Alloy C22
Alloy C22
Alloy C22
Alloy C22
Titanium Gr 1/2
Titanium Gr 1/2
Titanium Gr 1/2
Titanium Gr 1/2
Alloy 400
Alloy 400
Alloy 400
Alloy 400
Tantalum
Tantalum
Tantalum
Tantalum

Free propagation only


Longer Lead-time, Consult Factory
Longer Lead-time, Consult Factory
Longer Lead-time, Consult Factory
Longer Lead-time, Consult Factory
Longer Lead-time, Consult Factory
Longer Lead-time, Consult Factory
Longer Lead-time, Consult Factory
Longer Lead-time, Consult Factory
Longer Lead-time, Consult Factory
Longer Lead-time, Consult Factory
Longer Lead-time, Consult Factory
Longer Lead-time, Consult Factory
Longer Lead-time, Consult Factory
Longer Lead-time, Consult Factory
Longer Lead-time, Consult Factory
Longer Lead-time, Consult Factory
Consult Factory

Cone
Standard
23S
24S
26S
28S

Standard

Expanded
2AS
23H
24H
26H
28H
23T
24T
26T
28T
23M
24M
26M
28M
23Z
24Z
26Z
28Z
2XX
Tank Seal
Standard
P
Q

Standard

PTFE
Quartz

O-ring Material
Standard
V
K
E
B

Standard

Fluoroelastomer
Kalrez 6375
EPDM
Nitrile butadiene

Process Connection
Standard
NR

Standard

Antenna with Plate Design


NOTE: Customer supplied flange or see Table 10 on page 12 for flange options

Expanded
XX
BT
CT
DT
ET

Special Process Connection

Consult Factory

Tri-clamp connection

Flange Material

Note

3 in. Tri-Clamp Flange


4 in. Tri-Clamp Flange
6 in. Tri-Clamp Flange
8 in. Tri-Clamp Flange

SST 316L
SST 316L
SST 316L
SST 316L

Longer Lead-time, Consult Factory


Longer Lead-time, Consult Factory
Longer Lead-time, Consult Factory
Longer Lead-time, Consult Factory

Product Data Sheet


00813-0100-4024, Rev HA
June 2012

Rosemount 5600 Series

TABLE 2. Cone Antenna Ordering Information

The Standard offering represents the most common options. The starred options () should be selected for best delivery.
The Expanded offering is subject to additional delivery lead time.
Options
Standard
Q8

Standard

Material Traceability Certification per EN 10204 3.1.B

Typical Model Number: Selected code from Table 1 on page 4 24S P V NR

TABLE 3. Extended Cone Antenna Ordering Information

The Standard offering represents the most common options. The starred options () should be selected for best delivery.
The Expanded offering is subject to additional delivery lead time.
Antenna Type Antenna Size

Antenna Material

Note

Expanded
73S
74S
76S
7XX

3 in. (DN80) nozzles


SST 316L
4 in. (DN100) nozzles
SST 316L
6 in. (DN150) nozzles
SST 316L
Customer specific extended cone or material

Standard length 20 inch (500 mm)


Standard length 20 inch (500 mm)
Standard length 20 inch (500 mm)
Consult Factory

Tank Seal
Expanded
P
Q

PTFE
Quartz

O-ring Material
Expanded
V
K
E
B

Fluoroelastomer
Kalrez 6375
EPDM
Nitrile butadiene

Process Connections
Expanded
NR

Antenna with Plate Design

XX

NOTE: Customer supplied flange or see Table 10 on page 12 for flange options
Special Process Connection
Consult Factory

Options
Standard
Q8

Standard
Material Traceability Certification per EN 10204 3.1.B

Typical Model Number: Selected code from Table 1 on page 4 76S P V NR

Product Data Sheet


00813-0100-4024, Rev HA
June 2012

Rosemount 5600 Series

TABLE 4. Cone Antenna with Integrated Flushing Connection Ordering Information

The Standard offering represents the most common options. The starred options () should be selected for best delivery.
The Expanded offering is subject to additional delivery lead time.
Antenna Type

Antenna Size

Antenna Material

Note

SST 316L
SST 316L
SST 316L

Consult Factory
Consult Factory
Consult Factory

Cone with Integrated Flushing Connection


Expanded
94S
96S
98S

4 in. (DN100) nozzles


6 in. (DN150) nozzles
8 in. (DN200) nozzles

Tank Seal
Expanded
P
Q

PTFE
Quartz

O-ring Material
Expanded
V
K
E
B

Fluoroelastomer
Kalrez 6375
EPDM
Nitrile butadiene

Process Connection
Expanded
XX
CL
DL
FL
JL
KL
LL
CH
DH
FH
JH
KH
LH

Special Process Connection

Consult Factory

Stainless Steel Flange Welded to Antenna

Note(1)

4 in. ANSI Class 150


6 in. ANSI Class 150
8 in. ANSI Class 150
DN100 PN16
DN150 PN16
DN200 PN16
4 in. ANSI Class 150, SST, Higher Pressure
6 in. ANSI Class 150, SST, Higher Pressure
8 in. ANSI Class 150, SST, Higher Pressure
DN100 PN 16, SST< Higher Pressure
DN150 PN 16, SST< Higher Pressure
DN200 PN 16, SST< Higher Pressure

Max 101 psig at 392 F (7 bar at 200 C)


Max 145 psig at 392 F (10 bar at 200 C)
Max 145 psig at 392 F (10 bar at 200 C)
Max 72 psig at 392 F (5 bar at 200 C)
Max 87 psig at 392 F (6 bar at 200 C)
Max 87 psig at 392 F (6 bar at 200 C)
Max 145 psig at 752 F (10 bar at 400 C)
Max 145 psig at 752 F (10 bar at 400 C)
Max 145 psig at 752 F (10 bar at 400 C)
Max 145 psig at 752 F (10 bar at 400 C)
Max 145 psig at 752 F (10 bar at 400 C)
Max 145 psig at 752 F (10 bar at 400 C)

Options
Standard
Q8

Standard
Material Traceability Certification per EN 10204 3.1.B

Typical Model Number: Selected code from Table 1 on page 4 94S P K KL


(1) Pressure and Temperature rating may be lower depending on Tank Seal selection

Product Data Sheet


00813-0100-4024, Rev HA
June 2012

Rosemount 5600 Series

TABLE 5. Parabolic Antenna Ordering Information

The Standard offering represents the most common options. The starred options () should be selected for best delivery.
The Expanded offering is subject to additional delivery lead time.
Antenna Type Antenna Size

Antenna Material

Note

18 in. (440mm)
18 in. (440mm)

SST
SST

Clamped with Integrated Inclination, Low pressure version


Welded with Integrated Inclination, High pressure version

Customer Specific

Customer Specific

Consult Factory

Parabolic
Standard
45S
46S

Standard

Expanded
4XX
Tank Seal
Standard
P

Standard

PTFE

O-ring Material
Standard
V

Standard

Fluoroelastomer

Process Connections
Standard
NF

Standard

None, Flange Ready

Expanded
XX

Special Process Connection

Consult Factory

Options
Standard
Q8

Standard
Material Traceability Certification per EN 10204 3.1.B

Expanded
PB

PTFE Protective Cover (PTFE Bag) Not suitable for hazardous applications(1).

Typical Model Number: Selected code from Table 1 on page 4 45S P V NR


(1) Not suitable for use in Ex environments.

Product Data Sheet


00813-0100-4024, Rev HA
June 2012

Rosemount 5600 Series


TABLE 6. Process Seal Antenna Ordering Information

The Standard offering represents the most common options. The starred options () should be selected for best delivery.
The Expanded offering is subject to additional delivery lead time.
Antenna Type Antenna Size

Antenna Material

Note

Process Seal
Expanded
34S
36S

4 in. (DN100) nozzles


6 in. (DN150) nozzles

PTFE
PTFE

Tank Seal
Expanded
P

PTFE

O-ring Material
N

Not Applicable

Process Connection
Expanded
NF
XX
CA
DA
JA
KA

None, Customer to supply flange per dimensions on FIGURE 6.


Special Process Connection
Stainless Steel Flange

Flange Material

4 in. ANSI Class 150


6 in. ANSI Class 150
DN100 PN16
DN150 PN16

SST 316L
SST 316L
SST 316L
SST 316L

Consult Factory

Options
Standard
Q8

Standard
Material Traceability Certification per EN 10204 3.1.B

Typical Model Number: Selected code from Table 1 on page 4 34S P N JA

10

Product Data Sheet


00813-0100-4024, Rev HA
June 2012

Rosemount 5600 Series

TABLE 7. Transmitter Options Ordering Information (multiple selections allowed)

The Standard offering represents the most common options. The starred options () should be selected for best delivery.
The Expanded offering is subject to additional delivery lead time.
Options
Material Traceability Certification
Standard
Q8

Standard
Material Traceability Certification per EN 10204 3.1B

Calibration Data Certification


Standard
Q4

Standard
Calibration Data Certificate

Software Configuration
Standard
C1

Standard
Custom Software Configuration (CDS required with order)

Alarm Limits
Standard
C4
C8

Standard
NAMUR Alarm Level, High Alarm
Low Alarm (Standard Rosemount Alarm)

Conduit Adapters
Standard

Standard
1

G1
G2

/2 inch NPT Cable Gland Kit


1/2 inch NPT/ M20 Adapters (Set of 3)

Conduit Electrical Connector(1)


Expanded
M12, 4-pin, Male Connector (eurofast)
A size Mini, 4-pin, Male Connector (minifast)

GE
GM
Protective Cover
Expanded
PB(2)

PTFE Protective Cover (PTFE Bag)

Special Procedures
Standard
U1(3)

Standard
TV Overfill Protection

Expanded
P1(4)
QG
(1)
(2)
(3)
(4)

Hydrostatic Testing
GOST Primary Verification Certificate
Not available with certain hazardous location certifications. Contact an Emerson Process Management Representative for details.
For Parabolic Antenna only. Not suitable for hazardous applications.
Requires Secondary Output Code 3 or 4 (Active Output).
Not available in combination with Parabolic Antenna option codes.

TABLE 8. Typical Model Code Example


5601 A E1 P 5A 0 P E 24S P V NR
ATEX approval, passive HART primary output and display mounted on transmitter. Basic Volume calculation.
Antenna is a 4 inch Cone, SST with PTFE Seal and Fluoroelastomer O-rings. No options.

11

Product Data Sheet


00813-0100-4024, Rev HA
June 2012

Rosemount 5600 Series


Accessories
TABLE 9. Accessories Part Numbers
Part Number

Description

Note

Modems
03300-7004-0001
03300-7004-0002
05600-5004-0001

HART Modem and cables


HART USB Modem and cables
K2 RS485 Modbus Modem

Viator by MACTek
Viator by MACTek
For Sensor Bus Port connection (requires PC with 9-pin Serial port)

Cone Antenna Flanges


TABLE 10. Non-welded Flange Part Numbers
Stainless Steel Flanges
Part Number

Flange Size

Dimensions

Material

05600-1811-0211
05600-1811-0231
05600-1811-0311
05600-1811-0331
05600-1811-0411
05600-1811-0431
05600-1811-0611
05600-1811-0811
05600-1810-0231
05600-1810-0311
05600-1810-0331
05600-1810-0411
05600-1810-0431
05600-1810-0611
05600-1810-0811

ANSI 2 inch Class 150


ANSI 2 inch Class 300
ANSI 3 inch Class 150
ANSI 3 inch Class 300
ANSI 4 inch Class 150
ANSI 4 inch Class 300
ANSI 6 inch Class 150
ANSI 8 inch Class 150
DN50 PN40
DN80 PN16
DN80 PN40
DN100 PN16
DN100 PN40
DN150 PN16
DN200 PN16

Acc. To ANSI B16.5


Acc. To ANSI B16.5
Acc. To ANSI B16.5
Acc. To ANSI B16.5
Acc. To ANSI B16.5
Acc. To ANSI B16.5
Acc. To ANSI B16.5
Acc. To ANSI B16.5
Acc. To EN 1092-1
Acc. To EN 1092-1
Acc. To EN 1092-1
Acc. To EN 1092-1
Acc. To EN 1092-1
Acc. To EN 1092-1
Acc. To EN 1092-1

SST 316L (1)


SST 316L (1)
SST 316L
SST 316L
SST 316L
SST 316L
SST 316L
SST 316L
EN 1.4404 (2)
EN 1.4404 (2)
EN 1.4404 (2)
EN 1.4404 (2)
EN 1.4404 (2)
EN 1.4404 (2)
EN 1.4404 (2)

(1) Use gasket type la.


(2) Gasket type according to EN 1514-1 and bolting according to EN1515-2.

12

Product Data Sheet


00813-0100-4024, Rev HA
June 2012

Rosemount 5600 Series


Functional Specification

General
Field of Application

Measurement Principle
Microwave Output Power
Power Consumption
Beam Angle
Internal Calibration
Signal Processing
External Power Supply

Liquids, slurries, and solids:


Process vessels with agitators
Still-pipe or bridle-pipe mounting
Small nozzle openings on tanks with short measuring range
Various types of solid materials
10 GHz Frequency Modulated Continuous Wave (FMCW) radar (see Measurement Principle on
page 2 for details).
Max 1.0 mW
Maximum 10 W, Nominal 5 W
See Table 13 on page 19.
Internal digital reference for automatic compensation of radar sweep
Powerful and advanced digital signal processing using Fast Fourier Transform (FFT) and advanced
echo handling software.
Ultra wide 24-240 Vac or dc 0-60 Hz
The transmitter head has two separate junction boxes. One is for a Non-Intrinsically Safe (Non-IS)
primary signal output and power supply cables. The other is normally used for Intrinsically Safe (IS)
HART/analog outputs, or optionally, for a non-IS secondary analog output.
Primary Output is HART, either IS or Non-IS. The HART and secondary analog outputs can be either
active or passive.
Note:
The minimum power required at the transmitter power terminals is 20 V.

Outputs

Primary Output:
Alternative 1: HART + 4-20 mA current loop
(non-IS or IS option)
Alternative 2: RS-485 with Modbus communication
Secondary Outputs:
Analog 4-20 mA current loop, active (with power supplied by the Rosemount 5600) or passive (for
loop-supplied power) (Optional - see page 4)

Temperature Measurement
(optional)

1-3 spot elements, PT100 or Cu90, or 6 spot elements with common return. Input accuracy 0.9 F
(0.5 C). Average temperature or individual spots as output.

13

Product Data Sheet


00813-0100-4024, Rev HA
June 2012

Rosemount 5600 Series

4-20 mA HART and Secondary Outputs (Optional)


(Output Option Code 5A - 5D) - (See Ordering Information in Table 1 on page 4)
Output
HART analog 4-20 mA current loop, and Secondary 4-20 mA Output (Optional, active or passive)

Rosemount
5600 Series
Transmitter

4-20 mA with HART


and/or
4-20 mA (optional)

HART
Modem

Field
Communicator

Control System

PC with Rosemount
Radar Master

Remote
Display
(Optional)

Smart Wireless THUM Adapter

Galvanic Isolation
IS Electrical Parameters
Signal on Alarm (configurable)

Output Impedance
Analog Output Characteristics
(Passive or Active Out Options)
Load Limitations

14

The optional Smart Wireless THUM adapter can be mounted directly on the
transmitter or by using a remote mounting kit. IEC 62591 (WirelessHART) enables
access to multi-variable data and diagnostics, and adds wireless to almost any
measurement point. See the Rosemount Smart Wireless THUM adapter Product
Data Sheet (Document No. 00813-0100-4075) and Smart Wireless THUM Adapter
for Rosemount Process Level Transmitter Applications (Document No.
00840-0100-4026).
> 1500 V RMS or DC
See Product Certifications on page 23.
Standard: Low=3.8 mA, High=22 mA or freeze,
NAMUR NE43: High=22.50 mA,
Rosemount: Low=3.75 mA
>10 M
7-30 V
<700 (passive output with 24 V external supply)
<300 (active output)

Product Data Sheet


00813-0100-4024, Rev HA
June 2012
Display and Configuration
Display

Rosemount 5600 Series


Factory Mounted (Option code P)
The Rosemount 2210 offers basic configuration using the 4 soft keys on the display. Data
presentation on the LCD can be customized and allows many viewing alternatives by:
6-digit graphical LCD display, 128 x 64 pixels
7 text lines with 16 characters/line
Remote Mounted (Option Code R and T for temperature inputs)
The Rosemount 2210 is available as remote mounted and has optional temperature inputs (1-3 spot
elements PT100 or CU90)

Diagnostics

Failures: level, temperature, and volume measurement failure


Warnings: empty tank, full tank, database, hardware, software, and configuration warnings
Errors: database, hardware, software, and configuration warnings

Configuration Tools

Emerson Field Communicator (e.g. 375/475 Field Communicator),


Rosemount Radar Master (RRM) software package (included with delivery of transmitter),
Emerson AMS Device Manager or DeltaV or any other Device Description (DD) compatible host
systems. Certificates are available from all major host system vendors.
Notes:
To communicate using RRM or AMS Device Manager, a HART modem is required. The HART
modem is available as an RS232 or USB version (see Accessories on page 12).
The transmitter can be pre-configured by selecting option code C1 (see page 11) and sending a
complete Configuration Data Sheet (CDS). The CDS is available from www.rosemount.com.

Output Units

Level and Distance: ft, inch, m, cm, or mm


Volume: ft3, inch3, US gals, Imp gals, barrels, yd3, m3, or liters
Level Rate: ft/s, m/s
Temperature: F, C

Output Variables

Level, Distance, Volume, Level Rate, Signal Strength, Used defined, Temperature (1-6), and Average
Temperature

Damping

0-60 s (2 s, default value)

Process Temperature and Pressure

-40 to 70 C (-40 to 158 F)


LCD Readable between: -20 to 70 C (-4 to 158 F)
The final rating depends on antenna, tank seal, and O-ring selection. See Table 15 on page 28 for
further details.
Rosemount 5600 with Cone Antenna and Extended Cone Antenna (1)
Cone, Quartz tank seal
Cone, PTFE tank seal
1

145 psig at 212 F


10 bar at 100 C

73 psig at 392 F
5 bar at 200 C

-15 psig at 392 F


-1.0 bar at 200 C

798 psig at 752 F


55 bar at 400C

798 (55)
4

Pressure psig (bar)

Temperature and Pressure Limits


Ambient Temperature

145 (10)

73 (5)

0
-15 (-1)

-40
32
(-40) (0)

212
(100)

392
(200)

752
(400)

Process Temperature F (C)


Rosemount 5600 with Cone Antenna - Integrated Flushing Connection(1)
Maximum 145 psig at 392 F (10 bar at 200 C) or up to 145 psig at 752 F (10 bar at 400 C). See
Table 4 on page 8 for more information.
15

Product Data Sheet


00813-0100-4024, Rev HA
June 2012

Rosemount 5600 Series


Rosemount 5600 with Parabolic Antenna

45S, Clamped version, low pressure

Pressure psig (bar)

46S, Welded version, high pressure


145 (10)

1 145 psig at 392 F/ 10 bar at 200 C

2 2.9 psig at 392 F / 0.2 bar at 200 C

73 (5)
2.9 (0.2)
0

3 -2.9 psig at 392 F / -0.2 bar at 200 C

-2.9 (-0.2)
-40
(-40)

392 (200)

32
(0)

Process Temperature F (C)


Rosemount 5600 with Process Seal Antenna
6 PTFE

Pressure psig (bar)

4 PTFE
73 (5)

29(2)

0 psig at 302 F / 0 bar at 150 C

-15 psig at -40 F / -1.0 bar at -40 C

29 psig at -40 F / 2 bar at -40 C

73 psig at -40 F / 5 bar at -40 C

0
-15 (-1) 2
-40
(-40)

32
(0)

212 302 392


(100) (150) (200)

Process Temperature F (C)


ANSI Flange Rating
EN Flange Rating
(1)

16

According to ANSI B16.5


According to EN 1092-1

Pressure rating may be lower depending on flange selection.


Minimum / maximum flange temperature rating depends on O-ring selection. For further information, see Table 16 and Table 17 on page 28.

Product Data Sheet


00813-0100-4024, Rev HA
June 2012

Rosemount 5600 Series


Performance Specification

General
Reference Conditions

Instrument Accuracy (under


reference conditions)
Repeatability
Resolution
Ambient Temperature Effect
Update Interval
Linearity
Analog Out Temperature Drift
Analog Out Accuracy
Analog Out Resolution

Metal plate with no disturbing objects


Temperature: 68 F (20 C).
Pressure: 14 - 15 psi (960 - 1060 mbar).
Humidity: 25 - 75% RH.
Reference Measuring Range: 1.64 - 98 ft. (0.5 - 30 m)
0.2 in. (5 mm)
0.04 in. (1 mm)
0.04 in. (1 mm)
500 ppm of measured distance within the ambient temperature range
100 ms
0.01%
28 ppm/F (50 ppm/C)
300 A at 4 mA
600 A at 20 mA
0.5 A (0.003%)

Measuring Range
Measuring Range and Minimum
Dielectric Constant

0-164 ft. (0-50 m) Standard


0-324 ft. (0-99 m) Optional, requires special configuration
The measuring range depends on:
antenna type,
the dielectric constant of the liquid (r) (min. r=1.4)
process conditions
See Table 11 and Table 12 on page 19 for measuring range and minimum dielectric constant values.
For more information, ask your local Emerson Process Management representative.

Beam Angle and Beamwidth

For liquids with r that are smaller than 1.8 such as liquefied gases, an 8-inch or bigger diameter
antenna is recommended if measurement is done with free propagation. In this case, the measuring
range in calm surface tanks is 50 ft (15 m).
The 5600 transmitter installed in a pipe can measure products with a dielectric 1.4.
For detailed information on the
beam angle and beam width for
the Rosemount 5600 Series,
see Table 13 on page 19.

Distance

16 ft (5 m)
Beam Angle
33 ft (10 m)

49 ft (15 m)

66 ft (20 m)

Environment
Vibration Resistance
Electromagnetic Compatibility

EU Directive Compliance
Transient / Built-in Lightning
Protection

IEC 721-3-4 class 4M4


Emission and Immunity: EMC directive 204/108/EC. EN 61326-1:2006.
Immunity 50081-2.
Emission 50081-1.
Complies with 93/98/EEC
EN61326, EN61000-4-5, IEC801-5, level 2 kV

17

Product Data Sheet


00813-0100-4024, Rev HA
June 2012

Rosemount 5600 Series


Humidity
Radio Approvals

IEC 60068-2-3
FCC: Part 15C (K8CPRO & K8CPROX: Note: This device must be professionally installed and is only
authorized for use on sealed metal links)
R&TTE: ETSI EN 302 372 (Note: This device must be installed at a permanent fixed position at a
closed (not open) metallic tank or reinforced concrete tank, or similar enclosure structure made of
comparable attenuating material)

Climatic Class/Corrosion Class


UV Protection
Power Supply Fluctuation

IC: RSS210-5 (2827A- 5600PRO)


IEC 68-2-1, IEC 60068-2-52 test KB severity 2
ISO 4892-2
IEC 92 Part 504 sec. 3.5

TABLE 11. Rosemount 5600 Recommended Measuring Range for Optimum Performance, ft (m)
Rosemount 5600 Series

3-in. Cone
4-in. Process Seal
6-in. Process Seal
4-in. Cone
6-in. Cone
8-in. Cone
Parabolic
3-6-in. Cone in Still-Pipe

A
41 (12.5)
36 (11)
49 (15)
66 (20)
82 (25)
99 (30)
115 (35)
-

B
57 (17.5)
38 (11.5)
56 (17)
72 (22)
95 (29)
131 (40)
164 (50)
-

C
69 (21)
49 (15)
57 (17.5)
82 (25)
107 (32.5)
131 (40)
164 (50)
-

Dielectric Constant(1)
A
B
C
20 (6)
30 (9)
34 (10.5)
23 (7)
30 (9)
33 (10)
30 (9)
36 (11)
39 (12)
43 (13)
49 (15)
56 (17)
49 (15)
62 (19)
69 (21)
72 (22)
82 (25)
95 (29)
80 (24.5) 97 (29.5) 113 (34.5)
-

A
8 (2.5)
3 (1)(2)
5 (1.5)(2)
7 (2)(2)
15 (4.5)(2)
21 (6.5)
33 (10)
99 (30)

(1) A. Oil, gasoline and other hydrocarbons, petrochemicals (dielectric constant, r=1.9-4.0), in pipes (r>1.4)
B. Alcohols, concentrated acids, organic solvents, oil/water mixtures, and acetone (r=4.0-10)

C. Conductive liquids, e.g. water based solutions, dilute acids, and alkalis (r > 10)

(2) Not recommended.

18

B
8 (2.5)
7 (2)(2)
10 (3)(2)
16 (5)(2)
21 (6.5)(2)
36 (11)
56 (17)
99 (30)

C
11 (3.5)
11 (3.5)(2)
20 (6)(2)
25 (7.5)(2)
33 (10)(2)
46 (14)
66 (20)
99 (30)

Product Data Sheet


00813-0100-4024, Rev HA
June 2012

Rosemount 5600 Series

TABLE 12. Rosemount 5600, Maximum Recommended Measuring Range, ft (m)


Rosemount 5600 Series

3-in. Cone
4-in. Process Seal
6-in. Process Seal
4-in. Cone
6-in. Cone
8-in. Cone
Parabolic
3-6-in. Cone in Still-Pipe

A
52 (16)
49 (15)
59 (18)
82 (25)
98 (30)
115 (35)
131 (40)
-

B
72 (22)
51 (15.5)
67 (20.5)
89 (27)
112 (34)
148 (45)
164 (50)
-

C
92 (28)
59 (18)
80 (24.5)
98 (30)
131 (40)
164 (50)
164 (50)
-

Dielectric Constant(1)
A
B
C
30 (9)
39 (12)
52 (16)
31 (9.5)
34 (10.5) 41 (12.5)
36 (11)
41 (12.5) 54 (16.5)
52 (16)
59 (18)
71 (21.5)
66 (20)
80 (24.5) 92 (28)
85 (26)
95 (29)
107 (32.5)
98 (30)
115 (35)
131 (40)
-

A
16 (5)
8 (2.5)(2)
10 (3)(2)
10 (3)
21 (6.5)
26 (8)
46 (14)
164 (50)

B
20 (6)
11 (3.5)(2)
20 (6)(2)
21 (6.5)
33 (10)
46 (14)
82 (25)
164 (50)

C
21 (6.5)
20 (6)(2)
23 (7)(2)
33 (10)
43 (13)
52 (16)
98 (30)
164 (50)

(1) A. Oil, gasoline and other hydrocarbons, petrochemicals (dielectric constant, r=1.9-4.0), in pipes (r>1.4)
B. Alcohols, concentrated acids, organic solvents, oil/water mixtures, and acetone (r=4.0-10)

C. Conductive liquids, e.g. water based solutions, dilute acids, and alkalis (r > 10)

(2) Not recommended.

TABLE 13. Rosemount 5600 Beam Diameter and Angle


Distance, ft (m)
16 (5)

33 (10)

Antenna Type & Beam Angle


Cone 3 in 25
Cone 4 in/ Process Seal 4 inch 21
Cone 6 in/ Process Seal 6 inch 18
Cone 8 inch 15
Parabolic 10

49 (15)

66 (20)

Beam Diameter, ft (m)


7.2 (2.2)
6.2 (1.9)
5.2 (1.6)
4.3 (1.3)
3.0 (0.9)

14 (4.4)
12 (3.7)
10 (3.1)
8.5 (2.6)
5.6 (1.7)

22 (6.7)
18 (5.6)
15 (4.7)
13 (3.9)
8.5 (2.6)

29 (8.9)
24 (7.4)
21 (6.3)
17 (5.3)
11 (3.5)

19

Product Data Sheet

Rosemount 5600 Series

00813-0100-4024, Rev HA
June 2012

Physical Specification
Housing and Enclosure
Type
Electrical Connections

Housing Material
Ingress Protection
Ingress Protection - Remote
Display
Factory Sealed
Weight

Two separate junction boxes that separate electronics from cabling. The transmitter housing can be
rotated in any direction, and has interchangeable electronics without opening the tank.
3 X 1/2 inch NPT; for cable glands or conduit entries
Optional: 1/2 inch NPT Cable Gland Kit, 1/2 inch NPT / M20 Adapters (Set of 3)
Optional remote display (option code R and T): 2 x M20 Entries, 1 x M25 Entry;
max. cable length display - radar transmitter: 330 ft (100 m)
The recommended output cabling is a 4-wire, twisted and shielded instrument cable, min. 0.5 mm2
(AWG 20).
Permanent moulded cast aluminium, chromed and powder painted
IP66, IP 67, and NEMA 4
IP 67, mounted in separate enclosure with weather/dirt protection cover
See CSA Approvals information on page 25.
Transmitter Head (TH): 19.8 lb (9.0 kg)

Tank Connection and Antennas


Tank Connection

The tank connection consists of a tank seal and a flange:


Cone antennas, except for the Cone antennas with
Integrated Flushing Connection, are designed with a
protective plate. The plate and antenna (SST or
optional material) together with the tank seal and
o-rings (PTFE or Quartz) are the wetted parts exposed
to the tank atmosphere. This allows the use of an
existing flange, or a lower cost flange alternative.

Nut

1.38 (34)

Flange
Protective
Plate

Tank Seal

Loose flanges are also available (see Table 10 on


page 12).

Dimensions are inches (millimeters)


Flange Dimensions
Antennas

Follow ANSI, DIN standard


Material: Stainless steel 316L and Stainless Steel EN 1.4404
Cone, Parabolic, and Process Seal antennas. Extended Cone Antennas are available in SST 316L.
Cone Antennas are available with flushing connections (1/2-in. NPT).
Cone Antenna
Suitable for free-propagation and pipe-mounted installation
Cone extensions are available (see Table 3 on page 7)
Optional Cone antennas with cleaning/flushing connection are available (see Table 4 on page 8)
Parabolic Antenna
Suitable for solid materials (for example, cement)
Withstand heavy contamination
Can be equipped with a PTFE protective cover to reduce the effects of dusty environments
Process Seal Antenna
The dish of the Process Seal is made of PTFE
Only exposes material suitable for hygienic or corrosive applications (see Figure 6 on page 28 and
Table 6 on page 10)

20

Product Data Sheet


00813-0100-4024, Rev HA
June 2012

Rosemount 5600 Series

Antenna Dimensions

Cone Antenna: See Figure 1 on page 27


Extended Cone Antenna: See Figure 2 on page 27
Cone Antenna with Integrated Flushing Connection: See Figure 3 on page 27
Parabolic Antenna: See Figure 4 on page 27
Process Seal Antenna: See Figure 6 on page 28 and Table 16 on page 29
Antenna Weight
3-in. Cone Antenna: 2.20 lb. (1.0 kg)
4-in. Cone Antenna: 3.31 lb. (1.5 kg)
6-in. Cone Antenna: 4.41 lb. (2.0 kg)
8-in. Cone Antenna: 6.61 lb. (3.0 kg)
Parabolic Antenna: 17.6 lb. (8.0 kg)
4-in. Process Seal Antenna: 4.41 lb. (2.0 kg)
6-in. Process Seal Antenna: 5.51 lb. (2.5 kg)
Material Exposed to Tank
Cone Antenna (PTFE sealing)
Atmosphere
Antenna: 316L SST (EN1.4404) or Alloy C-22 or Tantalum or Alloy 400
Sealing: PTFE fluoropolymer
O-rings: fluoroelastomer or Kalrez perfluoroelastomer
Cone Antenna (Quartz sealing)
Antenna: 316L SST (EN1.4404) or Alloy C-22 or Tantalum or Alloy 400
Sealing: Quartz
O-rings: fluoroelastomer or Kalrez perfluoroelastomer
Parabolic Antenna
316L SST
FEP/PTFE fluoropolymer
Process Seal Antenna
PTFE fluoropolymer or Al2O3 (Aluminium oxide)
Installation and Mounting Considerations
Mechanical Mounting
The 5600 radar transmitter is easily carried to the tank top and mounted on a suitable nozzle or pipe.
Considerations
The radar transmitter should be installed as follows:
Antenna oriented perpendicular to a horizontal surface.
The transmitter should be mounted with as few fittings as possible within the beam angle.
Filling inlets creating turbulence should preferably be kept at a distance.
Choose as large antenna diameter as possible. A larger diameter concentrates the radar beam and
ensures maximum antenna gain. Increased antenna gain offers greater reflection of weak surface
echoes.
Dimensions are inches (millimeters).
0.4 (10)
or more (1)

(1)

For best measurement performance the nozzle


height should be shorter than the antenna or consider
an extended cone (FIGURE 3.) for your current
transmitter.

(2)

Recommended minimum distance for all antennas.


(Shorter distance may apply, consult factory).

24 (600)(2)
Pipe/Chamber Installations

If used correctly, pipe or chamber measurement can be advantageous in many applications:


Use cone antennas (3 to 6 in.)
The gap between the cone antenna and the still-pipe is limited to 0.4 in. (10 mm)

21

Product Data Sheet


00813-0100-4024, Rev HA
June 2012

Rosemount 5600 Series


TABLE 14. Antenna material and o-ring selection
Cone Antenna
Material
Stainless Steel 316L
Alloy C22
Titanium Gr1/Gr2
Tantalum
Alloy 400
PTFE
Tank Seal
PTFE
Quartz
O-Rings
Fluoroelastomer
Kalrez 6375
EPDM
Nitrile butadiene

22

Applicable

- Not applicable

Extended Cone Cone with Integrated


Antenna
Flushing Connection

Parabolic
Antenna

Process Seal
Antenna
-

Product Data Sheet


00813-0100-4024, Rev HA
June 2012

Rosemount 5600 Series


Product Certifications

SAFETY NOTE AND SPECIAL CONDITIONS FOR SAFE USE


(X-MARKINGS IN ATEX, AND IECEX CERTIFICATES)
As light alloys may be used as the enclosure (or other parts) they
may be at the accessible surface of this equipment, in the event of
rare incidents, ignitions sources due to impact and friction sparks
could occur. This shall be considered when the equipment is being
installed in locations that specifically require Group II, Category 1G
equipment.
Under certain extreme circumstances, the non-metallic parts of the
equipment may be capable of generating an ignition-capable level
or electrostatic charge. Therefore, when used for applications that
specifically require Group II, Category 1 equipment, the equipment
shall not be installed in a location where the external conditions
are conducive to the build-up of electrostatic charge on such
surfaces. Additionally, the equipment non-metallic parts shall only
be cleaned with a damp cloth

Hazardous Locations Certifications


ATEX Approvals
5600 Series Level Transmitter
E1

Certificate Number: Sira 03ATEX1294X


With Intrinsically Safe Outputs (only)
ATEX Marking:

II (2) (1) 1/2 GD

Safety Coding: Ex de IIC T6 Ga/Gb (-40 C to +70 C)


Ex t IIIC T85C Db IP65
With Non-IS Primary Output and IS Display Output
ATEX Marking: Ex de [ib] [ia] IIC T6 Ga/Gb
(-40 C to +70 C)
Ex t IIIC T85C Db IP65
II (1) 1/2 GD T85 C
Safety Coding: EEx de [ia] IIC T6 (-40 C Tamb +70 C)

Approved Manufacturing Locations


Rosemount Tank Radar AB Gothenburg, Sweden

With Non-IS Primary and/or Non-IS Secondary Outputs


ATEX Marking: Ex de [ia] IIC T6 Ga/Gb (-40 C to +70 C)
Ex t IIIC T85C Db IP65
II 1/2 GD

EU Conformity
Complies with 93/98/EEC. The most recent version of the EC
declaration of conformity can be found at www.rosemount.com.

ATEX Directive (94/9/EC)


Rosemount Inc. complies with the ATEX Directive.

Ordinary Location Certification for Factory Mutual


As standard, the transmitter has been examined and tested to
determine that the design meets basic electrical, mechanical, and
fire protection requirements by FM, a nationally recognized testing
laboratory (NRTL) as accredited by the Federal Occupational
Safety and Health Administration (OSHA).

5600 Series Radar Level Transmitter European ATEX


Directive Information
This document lists specific requirements which have to be fulfilled
to secure a safe installation and use of 5600 Series Radar Level
Transmitter in a hazardous area. Omission may jeopardize safety,
and Rosemount will not take any responsibility if requirements as
listed below are not fulfilled.

Canadian Registration Number (CRN)


The product design of the Cone Antenna has been accepted and
registered for use in Canada.
CRN: 0F1015.9C

Special Conditions for Safe Use: See first paragraph of the


Produce Certifications Chapter
Passive analog output 4-20 mA,
Label identification = HART passive.
Voltage compliance 7-30 V:
Ui = 30 V
Ii = 200 mA
Ci = 0
Li = 0
Uo = 0
Io = 0
Um = 250 V
Active analog output 4-20 mA,
Label identification = HART active.
Max load 300:
Uo = 23.1 V
Io = 125.7 mA
Po = 0.726 W
Cext =0.14 F
Lext = 2.2 mH
Ci = 0
Li = 0
The addition of an extra line out to the display interface
circuit, with the addition of safety components and
modification of the output parameters at connector X2
(formerly X7). The maximum combined parameters at this
connector are as follows:

23

Product Data Sheet

Rosemount 5600 Series


Connector X2
Uo = 7.84 V
Io = 385.6 mA
Po = 0.678 W
Ci = 0
Li = 0
Co = 9.3 ?F
Lo = 239 ?H
Lo/Ro = 52.8 ?H/ohm
FOUNDATION fieldbus model:
Ui <30 Vdc
Ii <300 mA
Pi <1.3 W
Ci =0 nF
Li =0 H

2210 Display Unit


Certificate Number: Sira 00ATEX2062
Without Temperature Inputs
ATEX Marking:

II 2 G

Safety Coding: Ex ib IIC T4 Gb (Ta -40 C to +70 C)


With Temperature Inputs
ATEX Marking:

II 2 (1) G

Safety Coding: Ex ib [ia Ga] IIC T4 Gb (Ta -40C to +70C)

24

00813-0100-4024, Rev HA
June 2012

Product Data Sheet


00813-0100-4024, Rev HA
June 2012

Rosemount 5600 Series

Factory Mutual (FM) Approvals


SPECIFIC CONDITIONS OF USE
1. WARNING Potential Electrostatic Charging Hazard The
enclosure is constructed from plastic. To prevent the risk of
electrostatic sparking the plastic surface should only be cleaned
with a damp cloth.

Explosion proof Ex de [ib/ia] IIC T6


Shall be installed in accordance with System control drawing
9150074-939.
Factory seal, conduit seal not required.

2210 Display Unit


Certificate Number: 2003.153280-1346165
Without Temperature Inputs
Intrinsically safe EEx ib IIC T4 (-40 C Tamb +70 C) With
Temperature Inputs

WARNING The apparatus enclosure contains


aluminum and is considered to constitute a potential
risk of ignition by impact or friction. Care must be
taken into account during installation and use to
prevent impact or friction.
5600 Series Level Transmitter
E5

Intrinsically safe EEx ib [ia] IIC T4 (-40 C Tamb +70 C)


Shall be installed in accordance with System control drawing
9150074-944.

IECEx Approvals

Certificate Number: 4D5A9.AX

5600 Series Level Transmitter

With Intrinsically safe outputs


(all versions except those listed below)

E7

Explosion proof with IS outputs for HAZLOC

Certificate Number: IECEx SIR 05.0024X


With Intrinsically Safe Outputs (only)
Safety Coding: Ex de IIC T6 Ga/Gb (-40 C to +70 C)

Class I, Division 1, Group A, B, C, and D, T6

Ex t IIIC T85 C Db IP65

Max operating temperature +70 C

With Non-IS Primary Output and IS Display Output

Dust ignition proof for use in Class II/III, Division 1,


Groups E, F, and G, T5.

Safety Coding: Ex de [ib] [ia] IIC T6 Ga/Gb


(-40 C to +70 C)

Use conductors rated at least 85 C


Shall be installed in accordance with System control drawing
9150074-994.

Ex t IIIC T85C Db IP65


With Non-IS Primary and/or Non-IS Secondary Outputs
Safety Coding: Ex de [ia] IIC T6 Ga/Gb (-40 to +70C)

With Non-IS Secondary Outputs (codes 1 and 3)

Ex t IIIC T85C Db IP65

Explosion proof
Class I, Division 1, Group A, B, C, and D, T6

Passive analog output 4-20 mA,

Max operating temperature +70 C

Label identification = HART passive.

Dust ignition proof for use in Class II/III, Division 1,


Groups E, F, and G, T5.

Voltage compliance 7-30 V:

Use conductors rated at least 85 C

2210 Display Unit


Certificate Number: 3008356
All Versions
Intrinsic Safe for HAZLOC
Class I, Division 1, Group A, B, C, and D T4
Max operating temperature +70 C
Shall be installed in accordance with System control drawing
9150074-997.

Canadian Standards Association (CSA


Approvals)
5600 Series Level Transmitter
E6

Certificate Number: 2003.153280-1346169


With Non-IS Primary and/or Secondary Outputs
Explosion proof Ex de IIC T6
Shall be installed in accordance with System control drawing
9150074-937.
Factory seal, conduit seal not required.

Ui = 30 V
Ii = 200 mA
Ci = 0
Li = 0
Uo = 0
Io = 0
Um = 250 V rms
Active analog output 4-20 mA,
Label identification = HART active.
Max load 300 :
Uo = 23.1 V
Io = 125.7 mA
Po = 0.726 W
Co = 0.14 F
Lo = 2.2 mH
Ci = 0
Li = 0
The addition of an extra line out to the display interface
circuit, with the addition of safety components and
modification of the output parameters at connector X2
(formerly X7). The maximum combined parameters at this
connector are as follows:

With IS Display Outputs, IS Primary and/or Secondary


Outputs

25

Product Data Sheet

Rosemount 5600 Series


Connector X2
Uo = 7.84 V
Io = 385.6 mA
Po = 0.678 W
Ci = 0
Li = 0
Co = 9.3 ?F
Lo = 239 ?H
Lo/Ro = 52.8 ?H/ohm
FOUNDATION fieldbus model:
Ui<30 Vdc
Ii<300 mA
Pi<1.3 W
Ci =0 nF
Li =0 H

2210 Display Unit


Certificate Number: IECEx SIR 05.0021
Without Temperature Inputs
Safety Coding: Ex ib IIC T4 (-40 C Tamb +70 C)
With Temperature Inputs
Safety Coding: Ex ib [ia] IIC T4 (-40 C Tamb +70 C)

NCC/INMETRO Approvals
5600 Series Level Transmitter
SPECIAL CONDITIONS FOR SAFE USE (X)
Refer to Certificate: 5100.08 X
Ex de IIC T6 Ga/Gb (-40 to +70C);
Ex de [ib Gb] [ia Ga] IIC T6 Ga/Gb (-40 to +70C);
Ex de [ia Ga] IIC T6 Ga/Gb (-40 to +70C)

China National Quality Supervision and Test


Center for Explosion Protected Electrical
Products (CQST)
5600 Series Level Transmitter
SPECIAL CONDITIONS FOR SAFE USE (X)
Refer to Certificates:
CNEx09.0324X-5600; CNEx09.0295X-5600;
CNEx09.294X-5600, CNEx08.0092X-5600;
Ex de [ib] [ia] IIC T6 T85C Ta: -40 to +70C; Ex de IIC
T6/DIP A20 T85C Ta: -40 to +70C IP65; Ex de [ia] IIC
T6/DIP A20 T85C Ta:-40 to +70C IP65;Ex nAL IIC T6 Ta:
-40 to +70COverfill Protection
Cert no: Z-65.16-417
U1

26

TV-tested and approved for overfill protection according to


the German WHG regulations

00813-0100-4024, Rev HA
June 2012

Product Data Sheet


00813-0100-4024, Rev HA
June 2012

Rosemount 5600 Series


Dimensional Drawings

FIGURE 1. Cone Antenna Dimensions(1)

FIGURE 2. Extended Cone Antenna Dimensions(1)

7.87 (200)

7.87 (200)

15.75 (400)

3.74 (95) (3 in. Cone)


5.91 (150) (4 in. Cone)
10.24 (260) (6 in. Cone)
14.57 (370) (8 in. Cone)

NOTE:
Other extended cone
lengths are also
available upon request.
Consult factory.

15.75 (400)

19.69 (500)

15 Angle
2.76 (70) (3 in. Cone)
3.66 (93) (4 in. Cone)
5.55 (141) (6 in. Cone)
7.44 (189) (8 in. Cone)

2.76 (70) (3 in. Cone)


3.66 (93) (4 in. Cone)
5.55 (141) (6 in. Cone)

FIGURE 3. Cone Antenna with Integrated


Flushing Connection Dimensions(1)

FIGURE 4. Parabolic Antenna Dimensions(1)

7.87 (200)
7.87 (200)

Connection
for tubing

15.75 (400)
18.11 (460)

5.12 (130) (4 in. Cone)


9.45 (240) (6 in. Cone)
13.98 (355) (8 in. Cone)

3.66 (93) (4 in. Cone)


5.55 (141) (6 in. Cone)
7.44 (189) (8 in. Cone)

6.4 (162)

17.36 (441)

(1) Dimensions are in inches (millimeters)

27

Product Data Sheet


00813-0100-4024, Rev HA
June 2012

Rosemount 5600 Series


FIGURE 5. Process Seal Antenna Dimensions(1)
7.87 (200)

21.65 (550) 4-in. process seal


25.59 (650) 6-in. process seal

6.30 (160) 4-in. process seal


8.58 (218) 6-in. process seal
(1)

Dimensions are in inches (millimeters)

FIGURE 6. Temperature Rating Considerations

O-rings

Flange
Temperature
measured
here

Process Temperature
measured here

NOTE:
Flange temperature depends on mounting conditions, such as
nozzle position, distance to maximum product level, nozzle
height, presence of insulation, etc.

TABLE 15. Flange Temperature Range depending on O-ring selection


O-ring Material
Fluoroelastomer
Ethylene Propylene (EPDM)
Kalrez 6375
Nitrile butadiene

28

Minimum Temperature
F (C) in air

Maximum Temperature
F (C) in air

5 (-15)
-40 (-40)
-4 (-20)
-31 (-35)

392 (200)
266 (130)
527 (275)
230 (110)

Product Data Sheet


00813-0100-4024, Rev HA
June 2012

Rosemount 5600 Series

FIGURE 7. Flange
5 X 45

+20
F1
Area for Marking

Ds1

Dh1

Di1
D1.5

TABLE 16. Dimensions for Stainless Steel Flange are in inches (millimeters)
Flange

Di

Dh

Ds

ANSI 4 inch Class 150


ANSI 6 inch Class 150
DN100 PN16
DN150 PN16

3.78 (96)
4.94 (125.5)
3.78 (96)
4.94 (125.5)

9.02 (229)
10.98 (279)
8.66 (220)
11.22 (285)

7.52 (191)
9.49 (241)
7.09 (180)
9.45 (240)

0.87 (22)
0.87 (22)
0.71 (18)
0.87 (22)

0.94 (23.8)
1.0 (25.4)
0.79 (20.0)
0.87 (22.0)

29

Product Data Sheet


00813-0100-4024, Rev HA
June 2012

Rosemount 5600 Series


Rosemount Level Solutions

Emerson provides a complete range of Rosemount products for level measurement applications.
Vibrating Fork Switches Point Level Detection

Guided Wave Radar Level and Interface Measurement

For high and low alarms, overfill protection, pump control,


including wide pressure and temperature requirements, and
hygienic applications. Flexible mounting. Immune to changing
process conditions and suitable for most liquids.
The product line consists of:

Multivariable, loop-powered Guided Wave Radar transmitters with


a wide range of probe styles to fit different liquids and solids
applications. The product line consists of:

Rosemount 2160 Wireless

Rosemount 2130 Enhanced

Rosemount 5300 Series Accurate, superior performance


transmitter with FOUNDATION fieldbus support

Rosemount 2120 Full-featured

Non-contacting Radar Level Measurement

Rosemount 2110 Compact

The Rosemount non-contacting radar family consists of:

Rosemount 3300 Series Versatile and easy-to-use


transmitter with proven reliability

Pressure Level or Interface Measurement


Rosemount DP Level products are proven, reliable, and can
be used in a variety of applications.

Rosemount 5400 Series Transmitters Loop-powered superior


performance transmitter with a wide range of antennas, for
liquid level measurement in most applications and process
conditions

Electronic Remote Sensors improve control on tall vessels


and distillation towers

Tuned-System Assemblies provide cost-efficient


measurements and improved performance compared to
traditional balanced systems

Rosemount 5600 Series Transmitters Power of 4-wire give


maximum sensitivity and performance for solids, challenging
reactors, rapid level changes and excessive process
conditions.

3051SAL, 3051L, and 2051L Level Transmitters combine


world class pressure instrumentation with direct-mount seals

1199 Seal Systems enable measurements in broad range of


process conditions and applications

Ultrasonic Level Measurement

Chambers for Process Level Instrumentation


Rosemount 9901 chambers for external mounting of process
level measurement and control instrumentation on process
vessels
Global quality assured design and manufacturing
Optimized for Rosemount 3300 and 5300 Series GWR

Top mounted, non-contacting for simple tank and open-air


process level measurements. Unaffected by fluid properties such
as density, viscosity, dirty coating, and corrosiveness.
Intrinsically Safe versions are available for operating in
hazardous areas
Rosemount 3100 Series Ultrasonic Level Transmitters
Rosemount 3490 Series Universal Controllers

Standard Terms and Conditions of Sale can be found at www.rosemount.com\terms_of_sale


The Emerson logo is a trademark and service mark of Emerson Electric Co.
Rosemount and the Rosemount logotype are registered trademarks of Rosemount Inc.
Fisher is a mark owned by Fisher Controls International LLC, a member of the Emerson Process Management business division of Emerson
Electric Co.
PlantWeb is a registered trademark of the Emerson Process Management group of companies.
HART and WirelessHART are registered trademarks of the HART Communication Foundation.
Kalrez is a registered trademark of Du Pont Performance Elastomers.
DeltaV is a trademark of Emerson Process Management group of companies.
Eurofast and Minifast are registered trademarks of Turck Inc.
Masoneilan is a registered trademark of Dresser Inc.
All other marks are the property of their respective owners.
6/12 Rosemount Inc. All rights reserved.

Emerson Process Management


Rosemount Measurement
8200 Market Boulevard
Chanhassen MN 55317 USA
Tel (USA) 1 800 999 9307
Tel (International) +1 952 906 8888
Fax + 1 952 906 8889

00813-0100-4024 Rev HA, 6/12

Europe Process Management


Blegistrasse 23
P.O. Box 1046
CH 6341 Baar
Switzerland
Tel +41 (0) 41 768 6111
Fax +41 (0) 41 768 6300

Emerson FZE
P.O. Box 17033
Jebel Ali Free Zone
Dubai UAE
Tel +971 4 811 8100
Fax +971 4 886 5465

Emerson Process Management Asia


Pacific Pte Ltd
1 Pandan Crescent
Singapore 128461
Tel +65 6777 8211
Fax +65 6777 0947
Service Support Hotline: +65 6770 8711
Email: [email protected]

You might also like