Product Data Sheet
00813-0100-4024, Rev HA
June 2012
Rosemount 5600 Series
Superior Performance Four-Wire
Non-Contacting Radar Level Transmitter
Best performance and uptime provided by
market leading sensitivity
Unique signal processing allows for
challenging process conditions
Extremely reliable and accurate level
transmitter due to its high repeatability
Easy connection with adjustable power
supply, 24-240 Vac/dc, 0-60 Hz
Easy configuration and setup with intelligent
software support
High application flexibility with an extensive
selection of antennas and materials
Minimized maintenance costs with no contact
and no moving parts; no re-calibration
required
Interchangeable transmitter heads and
antennas
Contents
Superior Performance, When Applications Get Tough. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Functional Specification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Performance Specification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Physical Specification. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Product Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Dimensional Drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
www.rosemount.com
Product Data Sheet
Rosemount 5600 Series
00813-0100-4024, Rev HA
June 2012
Superior Performance, When Applications Get Tough
MEASUREMENT PRINCIPLE
The level of the product in the tank is measured by radar signals transmitted
from the antenna at the tank top. After the radar signal is reflected by the
product surface, the echo is picked up by the antenna. As the signal is
varying in frequency, the echo has a slightly different frequency compared to
the signal transmitted at that moment. The difference in frequency is
proportional to the distance to the product surface, and level can be
accurately calculated. This method is called Frequency Modulated
Continuous Wave (FMCW).
Applications with, for example, turbulence, foam, long measuring ranges,
disturbing objects, and low dielectric constants can reduce the energy
reflecting back and, in worst case, eliminate it completely with the result that
no surface can be detected. The reflection intensity can however be
improved by using a highly sensitive radar, the optimal antenna type, and as
large antenna as possible.
RADAR TECHNOLOGY BENEFITS
Direct level measurement means that virtually no compensation is
needed for changing process conditions (such as density, conductivity,
temperature, pressure, viscosity, pH, dielectric etc.) which results in high
application flexibility
Challenging reactor and mixing
tanks, and tanks with rapid level
changes
Accurate, reliable measurement that requires no re-calibration, meaning
improved uptime
The non-contacting radar transmitter with no moving parts means
minimized maintenance
Good for dirty, coating, crystallizing, and corrosive applications
Top down measurement means simple installation with no empty tank
requirements, and minimized risk for leakages
SPECIAL 5600 FEATURES
For the most challenging applications
4-wire transmitters with maximum sensitivity and performance
Suitable for solids, liquids, and slurries in challenging reactors, with rapid
level changes and excessive process conditions
Low DK solids including lime,
cement, fly ash, corn, and many more
Manages high pressures and temperature
Handles long measuring ranges
Application flexibility with a wide selection of materials, process
connections, antenna styles, and accessories
Cone
Tri- Process
Clamp Seal
Dust
Cover
Parabolic
Antenna
Full range of antenna styles
Product Data Sheet
00813-0100-4024, Rev HA
June 2012
Rosemount 5600 Series
Best Performance and Uptime
The power of 4 wires provides the highest sensitivity and the
ability to detect weak radar echoes in challenging process
environments
Smart EchoLogic with registration of disturbance echoes
provides the ability to handle weak echoes reliably and
identifies the true echo from the clutter
Ability to handle disturbing factors, longer measuring ranges,
and lower dielectrics
Greater measurement reliability margins result in less
downtime, higher safety, and better quality
Robust Design Reduces Costs and Increases Safety
The detachable transmitter head allows the tank to remain
sealed
The dual compartment housing separates cable connections
and electronics, which provides safer handling and improved
moisture protection
Adjustable power supply, 24-240 Vac/dc, 0-60 Hz
Interchangeable transmitter heads and antennas
Allows for easy replacement by standard tank connections
The Smart Wireless
THUM adapter enables
level communication
with previously
inaccessible and remote
tanks
Easy Installation and Plant Integration
Seamless system integration with HART, Modbus, or IEC
62591 (WirelessHART) with the Smart Wireless THUM
adapter
Secondary analog 4-20 mA output
MultiVariable output includes the choice of level, distance,
volume, and signal strength
Pre-configured or easy, user-friendly configuration in
Rosemount RadarMaster with a five-step wizard, auto
connect, and online help
Any DD-compatible configuration tool such as AMS, or Field
Communicator can be used
Fully configurable with the remote- or factory-mounted LOI
Rosemount 2210 with temperature input option
Rosemount 2210
configurable display
with temperature input
Minimized Maintenance Reduces Cost
Non-contacting, no mechanical moving parts that require
maintenance
No re-calibration or compensation needed due to changing
process conditions
The user-friendly software provides easy online
troubleshooting with the echo curve tool, registration of
disturbance echoes, and logging
Predictive maintenance with advanced diagnostics and
PlantWeb alerts
Adjustments without opening the tank
The Rosemount RadarMaster enables easy
configuration and service with a user-friendly
interface including wizards, echo curve with movie
feature, offline/online configuration, extensive
online help, logging capabilities, and much more.
Product Data Sheet
Rosemount 5600 Series
00813-0100-4024, Rev HA
June 2012
Rosemount 5601 Radar Level Transmitter
Rosemount 5601 Radar Level Transmitter is a reliable 4-wire radar level transmitter
designed for outstanding performance in a wide range of applications and process
conditions. Characteristics include:
Handles a wide range of process conditions
Extensive selection of antennas and materials
HART 4-20 mA, Modbus, or IEC 62591 (WirelessHART) with the Smart Wireless THUM
adapter
Additional Information
Specifications: page 13
Product Certifications: page 23
Dimensional Drawings: page 27
Ordering
Information
TABLE 1. Rosemount 5601 Radar Level Transmitter Ordering Information
The Standard offering represents the most common options. The starred options () should be selected for best delivery.
The Expanded offering is subject to additional delivery lead time.
Model
Product Description
5601
Radar Level Transmitter for Process Applications
Frequency Band
Standard
U
S
A
Standard
US Market Only (10 GHz)
Switzerland Market Only (10 GHz)
All Other Markets (10 GHz)
Product Certification
Standard
NA
E1
E5
E6
E7
Standard
None
CENELEC/ATEX Flameproof
FM Explosion-proof
CSA Explosion-proof
IECEx Flameproof
24-240 Vdc/ac 0-60 Hz
Power Supply
Standard
P
Primary Output
Standard
5A
5B
5C
5D
8A
Standard
4-20 mA with HART communication, Passive Output
4-20 mA with HART communication, Passive Output, Intrinsically Safe Circuit (1)
4-20 mA with HART communication, Active Output
4-20 mA with HART communication, Active Output, Intrinsically Safe Circuit (1)
RS 485 Protocol - Modbus
Secondary Output(2)(3)
Standard
0
1(4)
2(4)
3
4
Standard
None
4-20 mA, Passive Output (5)
4-20 mA, Passive Output, Intrinsically Safe Circuit (1)
4-20 mA, Active Output (5)
4-20 mA, Active Output, Intrinsically Safe Circuit (1)
Product Data Sheet
00813-0100-4024, Rev HA
June 2012
Rosemount 5600 Series
TABLE 1. Rosemount 5601 Radar Level Transmitter Ordering Information
The Standard offering represents the most common options. The starred options () should be selected for best delivery.
The Expanded offering is subject to additional delivery lead time.
Display Unit
Standard
N
P
R
T
Standard
None
LOI, Factory mounted on transmitter
LOI, Remote mounted
LOI, Remote mounted with temp inputs (1-6 spot elements with common returns)
Volume Calculation
Standard
E
V
Standard
Basic Volume Equations (Standard)
Strapping Table, up to 100 points
Typical Model Number: 5601 S E1 P 5A 0 P E Antenna Selection (6)
(1)
(2)
(3)
(4)
(5)
(6)
Intrinsically safe circuit only applicable if product certificate codes E1, E5, E6, or E7 is selected.
Secondary output codes are not available in a combination of E6 CSA and Primary Output codes 5A, 5B, 5C, or 5D.
Secondary output codes 1, 2, 3, and 4 require an isolator when used in combination with 7A, 7B, or 8A.
Not available in combination with Primary Output codes 5A, 5B, 5C, or 5D.
Not allowed in combination with Display Unit codes P, R, or T.
Select the antenna type and options using Table 2, Table 3, Table 4, Table 6, and Table .
Product Data Sheet
00813-0100-4024, Rev HA
June 2012
Rosemount 5600 Series
TABLE 2. Cone Antenna Ordering Information
The Standard offering represents the most common options. The starred options () should be selected for best delivery.
The Expanded offering is subject to additional delivery lead time.
Antenna Type Antenna Size
Antenna Material
Note
3 in. (DN80) nozzles
4 in. (DN100) nozzles
6 in. (DN150) nozzles
8 in. (DN200) nozzles
SST 316L
SST 316L
SST 316L
SST 316L
Pipe Installation Only
Free propagation or 4 pipe
Free propagation or 6 pipe
Free propagation only
10 in. (DN250) nozzles
3 in. (DN80) nozzles
4 in. (DN100) nozzles
6 in. (DN150) nozzles
8 in. (DN200) nozzles
3 in. (DN80) nozzles
4 in. (DN100) nozzles
6 in. (DN150) nozzles
8 in. (DN200) nozzles
3 in. (DN80) nozzles
4 in. (DN100) nozzles
6 in. (DN150) nozzles
8 in. (DN200) nozzles
3 in. (DN80) nozzles
4 in. (DN100) nozzles
6 in. (DN150) nozzles
8 in. (DN200) nozzles
Customer specific cone or material
SST 316L
Alloy C22
Alloy C22
Alloy C22
Alloy C22
Titanium Gr 1/2
Titanium Gr 1/2
Titanium Gr 1/2
Titanium Gr 1/2
Alloy 400
Alloy 400
Alloy 400
Alloy 400
Tantalum
Tantalum
Tantalum
Tantalum
Free propagation only
Longer Lead-time, Consult Factory
Longer Lead-time, Consult Factory
Longer Lead-time, Consult Factory
Longer Lead-time, Consult Factory
Longer Lead-time, Consult Factory
Longer Lead-time, Consult Factory
Longer Lead-time, Consult Factory
Longer Lead-time, Consult Factory
Longer Lead-time, Consult Factory
Longer Lead-time, Consult Factory
Longer Lead-time, Consult Factory
Longer Lead-time, Consult Factory
Longer Lead-time, Consult Factory
Longer Lead-time, Consult Factory
Longer Lead-time, Consult Factory
Longer Lead-time, Consult Factory
Consult Factory
Cone
Standard
23S
24S
26S
28S
Standard
Expanded
2AS
23H
24H
26H
28H
23T
24T
26T
28T
23M
24M
26M
28M
23Z
24Z
26Z
28Z
2XX
Tank Seal
Standard
P
Q
Standard
PTFE
Quartz
O-ring Material
Standard
V
K
E
B
Standard
Fluoroelastomer
Kalrez 6375
EPDM
Nitrile butadiene
Process Connection
Standard
NR
Standard
Antenna with Plate Design
NOTE: Customer supplied flange or see Table 10 on page 12 for flange options
Expanded
XX
BT
CT
DT
ET
Special Process Connection
Consult Factory
Tri-clamp connection
Flange Material
Note
3 in. Tri-Clamp Flange
4 in. Tri-Clamp Flange
6 in. Tri-Clamp Flange
8 in. Tri-Clamp Flange
SST 316L
SST 316L
SST 316L
SST 316L
Longer Lead-time, Consult Factory
Longer Lead-time, Consult Factory
Longer Lead-time, Consult Factory
Longer Lead-time, Consult Factory
Product Data Sheet
00813-0100-4024, Rev HA
June 2012
Rosemount 5600 Series
TABLE 2. Cone Antenna Ordering Information
The Standard offering represents the most common options. The starred options () should be selected for best delivery.
The Expanded offering is subject to additional delivery lead time.
Options
Standard
Q8
Standard
Material Traceability Certification per EN 10204 3.1.B
Typical Model Number: Selected code from Table 1 on page 4 24S P V NR
TABLE 3. Extended Cone Antenna Ordering Information
The Standard offering represents the most common options. The starred options () should be selected for best delivery.
The Expanded offering is subject to additional delivery lead time.
Antenna Type Antenna Size
Antenna Material
Note
Expanded
73S
74S
76S
7XX
3 in. (DN80) nozzles
SST 316L
4 in. (DN100) nozzles
SST 316L
6 in. (DN150) nozzles
SST 316L
Customer specific extended cone or material
Standard length 20 inch (500 mm)
Standard length 20 inch (500 mm)
Standard length 20 inch (500 mm)
Consult Factory
Tank Seal
Expanded
P
Q
PTFE
Quartz
O-ring Material
Expanded
V
K
E
B
Fluoroelastomer
Kalrez 6375
EPDM
Nitrile butadiene
Process Connections
Expanded
NR
Antenna with Plate Design
XX
NOTE: Customer supplied flange or see Table 10 on page 12 for flange options
Special Process Connection
Consult Factory
Options
Standard
Q8
Standard
Material Traceability Certification per EN 10204 3.1.B
Typical Model Number: Selected code from Table 1 on page 4 76S P V NR
Product Data Sheet
00813-0100-4024, Rev HA
June 2012
Rosemount 5600 Series
TABLE 4. Cone Antenna with Integrated Flushing Connection Ordering Information
The Standard offering represents the most common options. The starred options () should be selected for best delivery.
The Expanded offering is subject to additional delivery lead time.
Antenna Type
Antenna Size
Antenna Material
Note
SST 316L
SST 316L
SST 316L
Consult Factory
Consult Factory
Consult Factory
Cone with Integrated Flushing Connection
Expanded
94S
96S
98S
4 in. (DN100) nozzles
6 in. (DN150) nozzles
8 in. (DN200) nozzles
Tank Seal
Expanded
P
Q
PTFE
Quartz
O-ring Material
Expanded
V
K
E
B
Fluoroelastomer
Kalrez 6375
EPDM
Nitrile butadiene
Process Connection
Expanded
XX
CL
DL
FL
JL
KL
LL
CH
DH
FH
JH
KH
LH
Special Process Connection
Consult Factory
Stainless Steel Flange Welded to Antenna
Note(1)
4 in. ANSI Class 150
6 in. ANSI Class 150
8 in. ANSI Class 150
DN100 PN16
DN150 PN16
DN200 PN16
4 in. ANSI Class 150, SST, Higher Pressure
6 in. ANSI Class 150, SST, Higher Pressure
8 in. ANSI Class 150, SST, Higher Pressure
DN100 PN 16, SST< Higher Pressure
DN150 PN 16, SST< Higher Pressure
DN200 PN 16, SST< Higher Pressure
Max 101 psig at 392 F (7 bar at 200 C)
Max 145 psig at 392 F (10 bar at 200 C)
Max 145 psig at 392 F (10 bar at 200 C)
Max 72 psig at 392 F (5 bar at 200 C)
Max 87 psig at 392 F (6 bar at 200 C)
Max 87 psig at 392 F (6 bar at 200 C)
Max 145 psig at 752 F (10 bar at 400 C)
Max 145 psig at 752 F (10 bar at 400 C)
Max 145 psig at 752 F (10 bar at 400 C)
Max 145 psig at 752 F (10 bar at 400 C)
Max 145 psig at 752 F (10 bar at 400 C)
Max 145 psig at 752 F (10 bar at 400 C)
Options
Standard
Q8
Standard
Material Traceability Certification per EN 10204 3.1.B
Typical Model Number: Selected code from Table 1 on page 4 94S P K KL
(1) Pressure and Temperature rating may be lower depending on Tank Seal selection
Product Data Sheet
00813-0100-4024, Rev HA
June 2012
Rosemount 5600 Series
TABLE 5. Parabolic Antenna Ordering Information
The Standard offering represents the most common options. The starred options () should be selected for best delivery.
The Expanded offering is subject to additional delivery lead time.
Antenna Type Antenna Size
Antenna Material
Note
18 in. (440mm)
18 in. (440mm)
SST
SST
Clamped with Integrated Inclination, Low pressure version
Welded with Integrated Inclination, High pressure version
Customer Specific
Customer Specific
Consult Factory
Parabolic
Standard
45S
46S
Standard
Expanded
4XX
Tank Seal
Standard
P
Standard
PTFE
O-ring Material
Standard
V
Standard
Fluoroelastomer
Process Connections
Standard
NF
Standard
None, Flange Ready
Expanded
XX
Special Process Connection
Consult Factory
Options
Standard
Q8
Standard
Material Traceability Certification per EN 10204 3.1.B
Expanded
PB
PTFE Protective Cover (PTFE Bag) Not suitable for hazardous applications(1).
Typical Model Number: Selected code from Table 1 on page 4 45S P V NR
(1) Not suitable for use in Ex environments.
Product Data Sheet
00813-0100-4024, Rev HA
June 2012
Rosemount 5600 Series
TABLE 6. Process Seal Antenna Ordering Information
The Standard offering represents the most common options. The starred options () should be selected for best delivery.
The Expanded offering is subject to additional delivery lead time.
Antenna Type Antenna Size
Antenna Material
Note
Process Seal
Expanded
34S
36S
4 in. (DN100) nozzles
6 in. (DN150) nozzles
PTFE
PTFE
Tank Seal
Expanded
P
PTFE
O-ring Material
N
Not Applicable
Process Connection
Expanded
NF
XX
CA
DA
JA
KA
None, Customer to supply flange per dimensions on FIGURE 6.
Special Process Connection
Stainless Steel Flange
Flange Material
4 in. ANSI Class 150
6 in. ANSI Class 150
DN100 PN16
DN150 PN16
SST 316L
SST 316L
SST 316L
SST 316L
Consult Factory
Options
Standard
Q8
Standard
Material Traceability Certification per EN 10204 3.1.B
Typical Model Number: Selected code from Table 1 on page 4 34S P N JA
10
Product Data Sheet
00813-0100-4024, Rev HA
June 2012
Rosemount 5600 Series
TABLE 7. Transmitter Options Ordering Information (multiple selections allowed)
The Standard offering represents the most common options. The starred options () should be selected for best delivery.
The Expanded offering is subject to additional delivery lead time.
Options
Material Traceability Certification
Standard
Q8
Standard
Material Traceability Certification per EN 10204 3.1B
Calibration Data Certification
Standard
Q4
Standard
Calibration Data Certificate
Software Configuration
Standard
C1
Standard
Custom Software Configuration (CDS required with order)
Alarm Limits
Standard
C4
C8
Standard
NAMUR Alarm Level, High Alarm
Low Alarm (Standard Rosemount Alarm)
Conduit Adapters
Standard
Standard
1
G1
G2
/2 inch NPT Cable Gland Kit
1/2 inch NPT/ M20 Adapters (Set of 3)
Conduit Electrical Connector(1)
Expanded
M12, 4-pin, Male Connector (eurofast)
A size Mini, 4-pin, Male Connector (minifast)
GE
GM
Protective Cover
Expanded
PB(2)
PTFE Protective Cover (PTFE Bag)
Special Procedures
Standard
U1(3)
Standard
TV Overfill Protection
Expanded
P1(4)
QG
(1)
(2)
(3)
(4)
Hydrostatic Testing
GOST Primary Verification Certificate
Not available with certain hazardous location certifications. Contact an Emerson Process Management Representative for details.
For Parabolic Antenna only. Not suitable for hazardous applications.
Requires Secondary Output Code 3 or 4 (Active Output).
Not available in combination with Parabolic Antenna option codes.
TABLE 8. Typical Model Code Example
5601 A E1 P 5A 0 P E 24S P V NR
ATEX approval, passive HART primary output and display mounted on transmitter. Basic Volume calculation.
Antenna is a 4 inch Cone, SST with PTFE Seal and Fluoroelastomer O-rings. No options.
11
Product Data Sheet
00813-0100-4024, Rev HA
June 2012
Rosemount 5600 Series
Accessories
TABLE 9. Accessories Part Numbers
Part Number
Description
Note
Modems
03300-7004-0001
03300-7004-0002
05600-5004-0001
HART Modem and cables
HART USB Modem and cables
K2 RS485 Modbus Modem
Viator by MACTek
Viator by MACTek
For Sensor Bus Port connection (requires PC with 9-pin Serial port)
Cone Antenna Flanges
TABLE 10. Non-welded Flange Part Numbers
Stainless Steel Flanges
Part Number
Flange Size
Dimensions
Material
05600-1811-0211
05600-1811-0231
05600-1811-0311
05600-1811-0331
05600-1811-0411
05600-1811-0431
05600-1811-0611
05600-1811-0811
05600-1810-0231
05600-1810-0311
05600-1810-0331
05600-1810-0411
05600-1810-0431
05600-1810-0611
05600-1810-0811
ANSI 2 inch Class 150
ANSI 2 inch Class 300
ANSI 3 inch Class 150
ANSI 3 inch Class 300
ANSI 4 inch Class 150
ANSI 4 inch Class 300
ANSI 6 inch Class 150
ANSI 8 inch Class 150
DN50 PN40
DN80 PN16
DN80 PN40
DN100 PN16
DN100 PN40
DN150 PN16
DN200 PN16
Acc. To ANSI B16.5
Acc. To ANSI B16.5
Acc. To ANSI B16.5
Acc. To ANSI B16.5
Acc. To ANSI B16.5
Acc. To ANSI B16.5
Acc. To ANSI B16.5
Acc. To ANSI B16.5
Acc. To EN 1092-1
Acc. To EN 1092-1
Acc. To EN 1092-1
Acc. To EN 1092-1
Acc. To EN 1092-1
Acc. To EN 1092-1
Acc. To EN 1092-1
SST 316L (1)
SST 316L (1)
SST 316L
SST 316L
SST 316L
SST 316L
SST 316L
SST 316L
EN 1.4404 (2)
EN 1.4404 (2)
EN 1.4404 (2)
EN 1.4404 (2)
EN 1.4404 (2)
EN 1.4404 (2)
EN 1.4404 (2)
(1) Use gasket type la.
(2) Gasket type according to EN 1514-1 and bolting according to EN1515-2.
12
Product Data Sheet
00813-0100-4024, Rev HA
June 2012
Rosemount 5600 Series
Functional Specification
General
Field of Application
Measurement Principle
Microwave Output Power
Power Consumption
Beam Angle
Internal Calibration
Signal Processing
External Power Supply
Liquids, slurries, and solids:
Process vessels with agitators
Still-pipe or bridle-pipe mounting
Small nozzle openings on tanks with short measuring range
Various types of solid materials
10 GHz Frequency Modulated Continuous Wave (FMCW) radar (see Measurement Principle on
page 2 for details).
Max 1.0 mW
Maximum 10 W, Nominal 5 W
See Table 13 on page 19.
Internal digital reference for automatic compensation of radar sweep
Powerful and advanced digital signal processing using Fast Fourier Transform (FFT) and advanced
echo handling software.
Ultra wide 24-240 Vac or dc 0-60 Hz
The transmitter head has two separate junction boxes. One is for a Non-Intrinsically Safe (Non-IS)
primary signal output and power supply cables. The other is normally used for Intrinsically Safe (IS)
HART/analog outputs, or optionally, for a non-IS secondary analog output.
Primary Output is HART, either IS or Non-IS. The HART and secondary analog outputs can be either
active or passive.
Note:
The minimum power required at the transmitter power terminals is 20 V.
Outputs
Primary Output:
Alternative 1: HART + 4-20 mA current loop
(non-IS or IS option)
Alternative 2: RS-485 with Modbus communication
Secondary Outputs:
Analog 4-20 mA current loop, active (with power supplied by the Rosemount 5600) or passive (for
loop-supplied power) (Optional - see page 4)
Temperature Measurement
(optional)
1-3 spot elements, PT100 or Cu90, or 6 spot elements with common return. Input accuracy 0.9 F
(0.5 C). Average temperature or individual spots as output.
13
Product Data Sheet
00813-0100-4024, Rev HA
June 2012
Rosemount 5600 Series
4-20 mA HART and Secondary Outputs (Optional)
(Output Option Code 5A - 5D) - (See Ordering Information in Table 1 on page 4)
Output
HART analog 4-20 mA current loop, and Secondary 4-20 mA Output (Optional, active or passive)
Rosemount
5600 Series
Transmitter
4-20 mA with HART
and/or
4-20 mA (optional)
HART
Modem
Field
Communicator
Control System
PC with Rosemount
Radar Master
Remote
Display
(Optional)
Smart Wireless THUM Adapter
Galvanic Isolation
IS Electrical Parameters
Signal on Alarm (configurable)
Output Impedance
Analog Output Characteristics
(Passive or Active Out Options)
Load Limitations
14
The optional Smart Wireless THUM adapter can be mounted directly on the
transmitter or by using a remote mounting kit. IEC 62591 (WirelessHART) enables
access to multi-variable data and diagnostics, and adds wireless to almost any
measurement point. See the Rosemount Smart Wireless THUM adapter Product
Data Sheet (Document No. 00813-0100-4075) and Smart Wireless THUM Adapter
for Rosemount Process Level Transmitter Applications (Document No.
00840-0100-4026).
> 1500 V RMS or DC
See Product Certifications on page 23.
Standard: Low=3.8 mA, High=22 mA or freeze,
NAMUR NE43: High=22.50 mA,
Rosemount: Low=3.75 mA
>10 M
7-30 V
<700 (passive output with 24 V external supply)
<300 (active output)
Product Data Sheet
00813-0100-4024, Rev HA
June 2012
Display and Configuration
Display
Rosemount 5600 Series
Factory Mounted (Option code P)
The Rosemount 2210 offers basic configuration using the 4 soft keys on the display. Data
presentation on the LCD can be customized and allows many viewing alternatives by:
6-digit graphical LCD display, 128 x 64 pixels
7 text lines with 16 characters/line
Remote Mounted (Option Code R and T for temperature inputs)
The Rosemount 2210 is available as remote mounted and has optional temperature inputs (1-3 spot
elements PT100 or CU90)
Diagnostics
Failures: level, temperature, and volume measurement failure
Warnings: empty tank, full tank, database, hardware, software, and configuration warnings
Errors: database, hardware, software, and configuration warnings
Configuration Tools
Emerson Field Communicator (e.g. 375/475 Field Communicator),
Rosemount Radar Master (RRM) software package (included with delivery of transmitter),
Emerson AMS Device Manager or DeltaV or any other Device Description (DD) compatible host
systems. Certificates are available from all major host system vendors.
Notes:
To communicate using RRM or AMS Device Manager, a HART modem is required. The HART
modem is available as an RS232 or USB version (see Accessories on page 12).
The transmitter can be pre-configured by selecting option code C1 (see page 11) and sending a
complete Configuration Data Sheet (CDS). The CDS is available from www.rosemount.com.
Output Units
Level and Distance: ft, inch, m, cm, or mm
Volume: ft3, inch3, US gals, Imp gals, barrels, yd3, m3, or liters
Level Rate: ft/s, m/s
Temperature: F, C
Output Variables
Level, Distance, Volume, Level Rate, Signal Strength, Used defined, Temperature (1-6), and Average
Temperature
Damping
0-60 s (2 s, default value)
Process Temperature and Pressure
-40 to 70 C (-40 to 158 F)
LCD Readable between: -20 to 70 C (-4 to 158 F)
The final rating depends on antenna, tank seal, and O-ring selection. See Table 15 on page 28 for
further details.
Rosemount 5600 with Cone Antenna and Extended Cone Antenna (1)
Cone, Quartz tank seal
Cone, PTFE tank seal
1
145 psig at 212 F
10 bar at 100 C
73 psig at 392 F
5 bar at 200 C
-15 psig at 392 F
-1.0 bar at 200 C
798 psig at 752 F
55 bar at 400C
798 (55)
4
Pressure psig (bar)
Temperature and Pressure Limits
Ambient Temperature
145 (10)
73 (5)
0
-15 (-1)
-40
32
(-40) (0)
212
(100)
392
(200)
752
(400)
Process Temperature F (C)
Rosemount 5600 with Cone Antenna - Integrated Flushing Connection(1)
Maximum 145 psig at 392 F (10 bar at 200 C) or up to 145 psig at 752 F (10 bar at 400 C). See
Table 4 on page 8 for more information.
15
Product Data Sheet
00813-0100-4024, Rev HA
June 2012
Rosemount 5600 Series
Rosemount 5600 with Parabolic Antenna
45S, Clamped version, low pressure
Pressure psig (bar)
46S, Welded version, high pressure
145 (10)
1 145 psig at 392 F/ 10 bar at 200 C
2 2.9 psig at 392 F / 0.2 bar at 200 C
73 (5)
2.9 (0.2)
0
3 -2.9 psig at 392 F / -0.2 bar at 200 C
-2.9 (-0.2)
-40
(-40)
392 (200)
32
(0)
Process Temperature F (C)
Rosemount 5600 with Process Seal Antenna
6 PTFE
Pressure psig (bar)
4 PTFE
73 (5)
29(2)
0 psig at 302 F / 0 bar at 150 C
-15 psig at -40 F / -1.0 bar at -40 C
29 psig at -40 F / 2 bar at -40 C
73 psig at -40 F / 5 bar at -40 C
0
-15 (-1) 2
-40
(-40)
32
(0)
212 302 392
(100) (150) (200)
Process Temperature F (C)
ANSI Flange Rating
EN Flange Rating
(1)
16
According to ANSI B16.5
According to EN 1092-1
Pressure rating may be lower depending on flange selection.
Minimum / maximum flange temperature rating depends on O-ring selection. For further information, see Table 16 and Table 17 on page 28.
Product Data Sheet
00813-0100-4024, Rev HA
June 2012
Rosemount 5600 Series
Performance Specification
General
Reference Conditions
Instrument Accuracy (under
reference conditions)
Repeatability
Resolution
Ambient Temperature Effect
Update Interval
Linearity
Analog Out Temperature Drift
Analog Out Accuracy
Analog Out Resolution
Metal plate with no disturbing objects
Temperature: 68 F (20 C).
Pressure: 14 - 15 psi (960 - 1060 mbar).
Humidity: 25 - 75% RH.
Reference Measuring Range: 1.64 - 98 ft. (0.5 - 30 m)
0.2 in. (5 mm)
0.04 in. (1 mm)
0.04 in. (1 mm)
500 ppm of measured distance within the ambient temperature range
100 ms
0.01%
28 ppm/F (50 ppm/C)
300 A at 4 mA
600 A at 20 mA
0.5 A (0.003%)
Measuring Range
Measuring Range and Minimum
Dielectric Constant
0-164 ft. (0-50 m) Standard
0-324 ft. (0-99 m) Optional, requires special configuration
The measuring range depends on:
antenna type,
the dielectric constant of the liquid (r) (min. r=1.4)
process conditions
See Table 11 and Table 12 on page 19 for measuring range and minimum dielectric constant values.
For more information, ask your local Emerson Process Management representative.
Beam Angle and Beamwidth
For liquids with r that are smaller than 1.8 such as liquefied gases, an 8-inch or bigger diameter
antenna is recommended if measurement is done with free propagation. In this case, the measuring
range in calm surface tanks is 50 ft (15 m).
The 5600 transmitter installed in a pipe can measure products with a dielectric 1.4.
For detailed information on the
beam angle and beam width for
the Rosemount 5600 Series,
see Table 13 on page 19.
Distance
16 ft (5 m)
Beam Angle
33 ft (10 m)
49 ft (15 m)
66 ft (20 m)
Environment
Vibration Resistance
Electromagnetic Compatibility
EU Directive Compliance
Transient / Built-in Lightning
Protection
IEC 721-3-4 class 4M4
Emission and Immunity: EMC directive 204/108/EC. EN 61326-1:2006.
Immunity 50081-2.
Emission 50081-1.
Complies with 93/98/EEC
EN61326, EN61000-4-5, IEC801-5, level 2 kV
17
Product Data Sheet
00813-0100-4024, Rev HA
June 2012
Rosemount 5600 Series
Humidity
Radio Approvals
IEC 60068-2-3
FCC: Part 15C (K8CPRO & K8CPROX: Note: This device must be professionally installed and is only
authorized for use on sealed metal links)
R&TTE: ETSI EN 302 372 (Note: This device must be installed at a permanent fixed position at a
closed (not open) metallic tank or reinforced concrete tank, or similar enclosure structure made of
comparable attenuating material)
Climatic Class/Corrosion Class
UV Protection
Power Supply Fluctuation
IC: RSS210-5 (2827A- 5600PRO)
IEC 68-2-1, IEC 60068-2-52 test KB severity 2
ISO 4892-2
IEC 92 Part 504 sec. 3.5
TABLE 11. Rosemount 5600 Recommended Measuring Range for Optimum Performance, ft (m)
Rosemount 5600 Series
3-in. Cone
4-in. Process Seal
6-in. Process Seal
4-in. Cone
6-in. Cone
8-in. Cone
Parabolic
3-6-in. Cone in Still-Pipe
A
41 (12.5)
36 (11)
49 (15)
66 (20)
82 (25)
99 (30)
115 (35)
-
B
57 (17.5)
38 (11.5)
56 (17)
72 (22)
95 (29)
131 (40)
164 (50)
-
C
69 (21)
49 (15)
57 (17.5)
82 (25)
107 (32.5)
131 (40)
164 (50)
-
Dielectric Constant(1)
A
B
C
20 (6)
30 (9)
34 (10.5)
23 (7)
30 (9)
33 (10)
30 (9)
36 (11)
39 (12)
43 (13)
49 (15)
56 (17)
49 (15)
62 (19)
69 (21)
72 (22)
82 (25)
95 (29)
80 (24.5) 97 (29.5) 113 (34.5)
-
A
8 (2.5)
3 (1)(2)
5 (1.5)(2)
7 (2)(2)
15 (4.5)(2)
21 (6.5)
33 (10)
99 (30)
(1) A. Oil, gasoline and other hydrocarbons, petrochemicals (dielectric constant, r=1.9-4.0), in pipes (r>1.4)
B. Alcohols, concentrated acids, organic solvents, oil/water mixtures, and acetone (r=4.0-10)
C. Conductive liquids, e.g. water based solutions, dilute acids, and alkalis (r > 10)
(2) Not recommended.
18
B
8 (2.5)
7 (2)(2)
10 (3)(2)
16 (5)(2)
21 (6.5)(2)
36 (11)
56 (17)
99 (30)
C
11 (3.5)
11 (3.5)(2)
20 (6)(2)
25 (7.5)(2)
33 (10)(2)
46 (14)
66 (20)
99 (30)
Product Data Sheet
00813-0100-4024, Rev HA
June 2012
Rosemount 5600 Series
TABLE 12. Rosemount 5600, Maximum Recommended Measuring Range, ft (m)
Rosemount 5600 Series
3-in. Cone
4-in. Process Seal
6-in. Process Seal
4-in. Cone
6-in. Cone
8-in. Cone
Parabolic
3-6-in. Cone in Still-Pipe
A
52 (16)
49 (15)
59 (18)
82 (25)
98 (30)
115 (35)
131 (40)
-
B
72 (22)
51 (15.5)
67 (20.5)
89 (27)
112 (34)
148 (45)
164 (50)
-
C
92 (28)
59 (18)
80 (24.5)
98 (30)
131 (40)
164 (50)
164 (50)
-
Dielectric Constant(1)
A
B
C
30 (9)
39 (12)
52 (16)
31 (9.5)
34 (10.5) 41 (12.5)
36 (11)
41 (12.5) 54 (16.5)
52 (16)
59 (18)
71 (21.5)
66 (20)
80 (24.5) 92 (28)
85 (26)
95 (29)
107 (32.5)
98 (30)
115 (35)
131 (40)
-
A
16 (5)
8 (2.5)(2)
10 (3)(2)
10 (3)
21 (6.5)
26 (8)
46 (14)
164 (50)
B
20 (6)
11 (3.5)(2)
20 (6)(2)
21 (6.5)
33 (10)
46 (14)
82 (25)
164 (50)
C
21 (6.5)
20 (6)(2)
23 (7)(2)
33 (10)
43 (13)
52 (16)
98 (30)
164 (50)
(1) A. Oil, gasoline and other hydrocarbons, petrochemicals (dielectric constant, r=1.9-4.0), in pipes (r>1.4)
B. Alcohols, concentrated acids, organic solvents, oil/water mixtures, and acetone (r=4.0-10)
C. Conductive liquids, e.g. water based solutions, dilute acids, and alkalis (r > 10)
(2) Not recommended.
TABLE 13. Rosemount 5600 Beam Diameter and Angle
Distance, ft (m)
16 (5)
33 (10)
Antenna Type & Beam Angle
Cone 3 in 25
Cone 4 in/ Process Seal 4 inch 21
Cone 6 in/ Process Seal 6 inch 18
Cone 8 inch 15
Parabolic 10
49 (15)
66 (20)
Beam Diameter, ft (m)
7.2 (2.2)
6.2 (1.9)
5.2 (1.6)
4.3 (1.3)
3.0 (0.9)
14 (4.4)
12 (3.7)
10 (3.1)
8.5 (2.6)
5.6 (1.7)
22 (6.7)
18 (5.6)
15 (4.7)
13 (3.9)
8.5 (2.6)
29 (8.9)
24 (7.4)
21 (6.3)
17 (5.3)
11 (3.5)
19
Product Data Sheet
Rosemount 5600 Series
00813-0100-4024, Rev HA
June 2012
Physical Specification
Housing and Enclosure
Type
Electrical Connections
Housing Material
Ingress Protection
Ingress Protection - Remote
Display
Factory Sealed
Weight
Two separate junction boxes that separate electronics from cabling. The transmitter housing can be
rotated in any direction, and has interchangeable electronics without opening the tank.
3 X 1/2 inch NPT; for cable glands or conduit entries
Optional: 1/2 inch NPT Cable Gland Kit, 1/2 inch NPT / M20 Adapters (Set of 3)
Optional remote display (option code R and T): 2 x M20 Entries, 1 x M25 Entry;
max. cable length display - radar transmitter: 330 ft (100 m)
The recommended output cabling is a 4-wire, twisted and shielded instrument cable, min. 0.5 mm2
(AWG 20).
Permanent moulded cast aluminium, chromed and powder painted
IP66, IP 67, and NEMA 4
IP 67, mounted in separate enclosure with weather/dirt protection cover
See CSA Approvals information on page 25.
Transmitter Head (TH): 19.8 lb (9.0 kg)
Tank Connection and Antennas
Tank Connection
The tank connection consists of a tank seal and a flange:
Cone antennas, except for the Cone antennas with
Integrated Flushing Connection, are designed with a
protective plate. The plate and antenna (SST or
optional material) together with the tank seal and
o-rings (PTFE or Quartz) are the wetted parts exposed
to the tank atmosphere. This allows the use of an
existing flange, or a lower cost flange alternative.
Nut
1.38 (34)
Flange
Protective
Plate
Tank Seal
Loose flanges are also available (see Table 10 on
page 12).
Dimensions are inches (millimeters)
Flange Dimensions
Antennas
Follow ANSI, DIN standard
Material: Stainless steel 316L and Stainless Steel EN 1.4404
Cone, Parabolic, and Process Seal antennas. Extended Cone Antennas are available in SST 316L.
Cone Antennas are available with flushing connections (1/2-in. NPT).
Cone Antenna
Suitable for free-propagation and pipe-mounted installation
Cone extensions are available (see Table 3 on page 7)
Optional Cone antennas with cleaning/flushing connection are available (see Table 4 on page 8)
Parabolic Antenna
Suitable for solid materials (for example, cement)
Withstand heavy contamination
Can be equipped with a PTFE protective cover to reduce the effects of dusty environments
Process Seal Antenna
The dish of the Process Seal is made of PTFE
Only exposes material suitable for hygienic or corrosive applications (see Figure 6 on page 28 and
Table 6 on page 10)
20
Product Data Sheet
00813-0100-4024, Rev HA
June 2012
Rosemount 5600 Series
Antenna Dimensions
Cone Antenna: See Figure 1 on page 27
Extended Cone Antenna: See Figure 2 on page 27
Cone Antenna with Integrated Flushing Connection: See Figure 3 on page 27
Parabolic Antenna: See Figure 4 on page 27
Process Seal Antenna: See Figure 6 on page 28 and Table 16 on page 29
Antenna Weight
3-in. Cone Antenna: 2.20 lb. (1.0 kg)
4-in. Cone Antenna: 3.31 lb. (1.5 kg)
6-in. Cone Antenna: 4.41 lb. (2.0 kg)
8-in. Cone Antenna: 6.61 lb. (3.0 kg)
Parabolic Antenna: 17.6 lb. (8.0 kg)
4-in. Process Seal Antenna: 4.41 lb. (2.0 kg)
6-in. Process Seal Antenna: 5.51 lb. (2.5 kg)
Material Exposed to Tank
Cone Antenna (PTFE sealing)
Atmosphere
Antenna: 316L SST (EN1.4404) or Alloy C-22 or Tantalum or Alloy 400
Sealing: PTFE fluoropolymer
O-rings: fluoroelastomer or Kalrez perfluoroelastomer
Cone Antenna (Quartz sealing)
Antenna: 316L SST (EN1.4404) or Alloy C-22 or Tantalum or Alloy 400
Sealing: Quartz
O-rings: fluoroelastomer or Kalrez perfluoroelastomer
Parabolic Antenna
316L SST
FEP/PTFE fluoropolymer
Process Seal Antenna
PTFE fluoropolymer or Al2O3 (Aluminium oxide)
Installation and Mounting Considerations
Mechanical Mounting
The 5600 radar transmitter is easily carried to the tank top and mounted on a suitable nozzle or pipe.
Considerations
The radar transmitter should be installed as follows:
Antenna oriented perpendicular to a horizontal surface.
The transmitter should be mounted with as few fittings as possible within the beam angle.
Filling inlets creating turbulence should preferably be kept at a distance.
Choose as large antenna diameter as possible. A larger diameter concentrates the radar beam and
ensures maximum antenna gain. Increased antenna gain offers greater reflection of weak surface
echoes.
Dimensions are inches (millimeters).
0.4 (10)
or more (1)
(1)
For best measurement performance the nozzle
height should be shorter than the antenna or consider
an extended cone (FIGURE 3.) for your current
transmitter.
(2)
Recommended minimum distance for all antennas.
(Shorter distance may apply, consult factory).
24 (600)(2)
Pipe/Chamber Installations
If used correctly, pipe or chamber measurement can be advantageous in many applications:
Use cone antennas (3 to 6 in.)
The gap between the cone antenna and the still-pipe is limited to 0.4 in. (10 mm)
21
Product Data Sheet
00813-0100-4024, Rev HA
June 2012
Rosemount 5600 Series
TABLE 14. Antenna material and o-ring selection
Cone Antenna
Material
Stainless Steel 316L
Alloy C22
Titanium Gr1/Gr2
Tantalum
Alloy 400
PTFE
Tank Seal
PTFE
Quartz
O-Rings
Fluoroelastomer
Kalrez 6375
EPDM
Nitrile butadiene
22
Applicable
- Not applicable
Extended Cone Cone with Integrated
Antenna
Flushing Connection
Parabolic
Antenna
Process Seal
Antenna
-
Product Data Sheet
00813-0100-4024, Rev HA
June 2012
Rosemount 5600 Series
Product Certifications
SAFETY NOTE AND SPECIAL CONDITIONS FOR SAFE USE
(X-MARKINGS IN ATEX, AND IECEX CERTIFICATES)
As light alloys may be used as the enclosure (or other parts) they
may be at the accessible surface of this equipment, in the event of
rare incidents, ignitions sources due to impact and friction sparks
could occur. This shall be considered when the equipment is being
installed in locations that specifically require Group II, Category 1G
equipment.
Under certain extreme circumstances, the non-metallic parts of the
equipment may be capable of generating an ignition-capable level
or electrostatic charge. Therefore, when used for applications that
specifically require Group II, Category 1 equipment, the equipment
shall not be installed in a location where the external conditions
are conducive to the build-up of electrostatic charge on such
surfaces. Additionally, the equipment non-metallic parts shall only
be cleaned with a damp cloth
Hazardous Locations Certifications
ATEX Approvals
5600 Series Level Transmitter
E1
Certificate Number: Sira 03ATEX1294X
With Intrinsically Safe Outputs (only)
ATEX Marking:
II (2) (1) 1/2 GD
Safety Coding: Ex de IIC T6 Ga/Gb (-40 C to +70 C)
Ex t IIIC T85C Db IP65
With Non-IS Primary Output and IS Display Output
ATEX Marking: Ex de [ib] [ia] IIC T6 Ga/Gb
(-40 C to +70 C)
Ex t IIIC T85C Db IP65
II (1) 1/2 GD T85 C
Safety Coding: EEx de [ia] IIC T6 (-40 C Tamb +70 C)
Approved Manufacturing Locations
Rosemount Tank Radar AB Gothenburg, Sweden
With Non-IS Primary and/or Non-IS Secondary Outputs
ATEX Marking: Ex de [ia] IIC T6 Ga/Gb (-40 C to +70 C)
Ex t IIIC T85C Db IP65
II 1/2 GD
EU Conformity
Complies with 93/98/EEC. The most recent version of the EC
declaration of conformity can be found at www.rosemount.com.
ATEX Directive (94/9/EC)
Rosemount Inc. complies with the ATEX Directive.
Ordinary Location Certification for Factory Mutual
As standard, the transmitter has been examined and tested to
determine that the design meets basic electrical, mechanical, and
fire protection requirements by FM, a nationally recognized testing
laboratory (NRTL) as accredited by the Federal Occupational
Safety and Health Administration (OSHA).
5600 Series Radar Level Transmitter European ATEX
Directive Information
This document lists specific requirements which have to be fulfilled
to secure a safe installation and use of 5600 Series Radar Level
Transmitter in a hazardous area. Omission may jeopardize safety,
and Rosemount will not take any responsibility if requirements as
listed below are not fulfilled.
Canadian Registration Number (CRN)
The product design of the Cone Antenna has been accepted and
registered for use in Canada.
CRN: 0F1015.9C
Special Conditions for Safe Use: See first paragraph of the
Produce Certifications Chapter
Passive analog output 4-20 mA,
Label identification = HART passive.
Voltage compliance 7-30 V:
Ui = 30 V
Ii = 200 mA
Ci = 0
Li = 0
Uo = 0
Io = 0
Um = 250 V
Active analog output 4-20 mA,
Label identification = HART active.
Max load 300:
Uo = 23.1 V
Io = 125.7 mA
Po = 0.726 W
Cext =0.14 F
Lext = 2.2 mH
Ci = 0
Li = 0
The addition of an extra line out to the display interface
circuit, with the addition of safety components and
modification of the output parameters at connector X2
(formerly X7). The maximum combined parameters at this
connector are as follows:
23
Product Data Sheet
Rosemount 5600 Series
Connector X2
Uo = 7.84 V
Io = 385.6 mA
Po = 0.678 W
Ci = 0
Li = 0
Co = 9.3 ?F
Lo = 239 ?H
Lo/Ro = 52.8 ?H/ohm
FOUNDATION fieldbus model:
Ui <30 Vdc
Ii <300 mA
Pi <1.3 W
Ci =0 nF
Li =0 H
2210 Display Unit
Certificate Number: Sira 00ATEX2062
Without Temperature Inputs
ATEX Marking:
II 2 G
Safety Coding: Ex ib IIC T4 Gb (Ta -40 C to +70 C)
With Temperature Inputs
ATEX Marking:
II 2 (1) G
Safety Coding: Ex ib [ia Ga] IIC T4 Gb (Ta -40C to +70C)
24
00813-0100-4024, Rev HA
June 2012
Product Data Sheet
00813-0100-4024, Rev HA
June 2012
Rosemount 5600 Series
Factory Mutual (FM) Approvals
SPECIFIC CONDITIONS OF USE
1. WARNING Potential Electrostatic Charging Hazard The
enclosure is constructed from plastic. To prevent the risk of
electrostatic sparking the plastic surface should only be cleaned
with a damp cloth.
Explosion proof Ex de [ib/ia] IIC T6
Shall be installed in accordance with System control drawing
9150074-939.
Factory seal, conduit seal not required.
2210 Display Unit
Certificate Number: 2003.153280-1346165
Without Temperature Inputs
Intrinsically safe EEx ib IIC T4 (-40 C Tamb +70 C) With
Temperature Inputs
WARNING The apparatus enclosure contains
aluminum and is considered to constitute a potential
risk of ignition by impact or friction. Care must be
taken into account during installation and use to
prevent impact or friction.
5600 Series Level Transmitter
E5
Intrinsically safe EEx ib [ia] IIC T4 (-40 C Tamb +70 C)
Shall be installed in accordance with System control drawing
9150074-944.
IECEx Approvals
Certificate Number: 4D5A9.AX
5600 Series Level Transmitter
With Intrinsically safe outputs
(all versions except those listed below)
E7
Explosion proof with IS outputs for HAZLOC
Certificate Number: IECEx SIR 05.0024X
With Intrinsically Safe Outputs (only)
Safety Coding: Ex de IIC T6 Ga/Gb (-40 C to +70 C)
Class I, Division 1, Group A, B, C, and D, T6
Ex t IIIC T85 C Db IP65
Max operating temperature +70 C
With Non-IS Primary Output and IS Display Output
Dust ignition proof for use in Class II/III, Division 1,
Groups E, F, and G, T5.
Safety Coding: Ex de [ib] [ia] IIC T6 Ga/Gb
(-40 C to +70 C)
Use conductors rated at least 85 C
Shall be installed in accordance with System control drawing
9150074-994.
Ex t IIIC T85C Db IP65
With Non-IS Primary and/or Non-IS Secondary Outputs
Safety Coding: Ex de [ia] IIC T6 Ga/Gb (-40 to +70C)
With Non-IS Secondary Outputs (codes 1 and 3)
Ex t IIIC T85C Db IP65
Explosion proof
Class I, Division 1, Group A, B, C, and D, T6
Passive analog output 4-20 mA,
Max operating temperature +70 C
Label identification = HART passive.
Dust ignition proof for use in Class II/III, Division 1,
Groups E, F, and G, T5.
Voltage compliance 7-30 V:
Use conductors rated at least 85 C
2210 Display Unit
Certificate Number: 3008356
All Versions
Intrinsic Safe for HAZLOC
Class I, Division 1, Group A, B, C, and D T4
Max operating temperature +70 C
Shall be installed in accordance with System control drawing
9150074-997.
Canadian Standards Association (CSA
Approvals)
5600 Series Level Transmitter
E6
Certificate Number: 2003.153280-1346169
With Non-IS Primary and/or Secondary Outputs
Explosion proof Ex de IIC T6
Shall be installed in accordance with System control drawing
9150074-937.
Factory seal, conduit seal not required.
Ui = 30 V
Ii = 200 mA
Ci = 0
Li = 0
Uo = 0
Io = 0
Um = 250 V rms
Active analog output 4-20 mA,
Label identification = HART active.
Max load 300 :
Uo = 23.1 V
Io = 125.7 mA
Po = 0.726 W
Co = 0.14 F
Lo = 2.2 mH
Ci = 0
Li = 0
The addition of an extra line out to the display interface
circuit, with the addition of safety components and
modification of the output parameters at connector X2
(formerly X7). The maximum combined parameters at this
connector are as follows:
With IS Display Outputs, IS Primary and/or Secondary
Outputs
25
Product Data Sheet
Rosemount 5600 Series
Connector X2
Uo = 7.84 V
Io = 385.6 mA
Po = 0.678 W
Ci = 0
Li = 0
Co = 9.3 ?F
Lo = 239 ?H
Lo/Ro = 52.8 ?H/ohm
FOUNDATION fieldbus model:
Ui<30 Vdc
Ii<300 mA
Pi<1.3 W
Ci =0 nF
Li =0 H
2210 Display Unit
Certificate Number: IECEx SIR 05.0021
Without Temperature Inputs
Safety Coding: Ex ib IIC T4 (-40 C Tamb +70 C)
With Temperature Inputs
Safety Coding: Ex ib [ia] IIC T4 (-40 C Tamb +70 C)
NCC/INMETRO Approvals
5600 Series Level Transmitter
SPECIAL CONDITIONS FOR SAFE USE (X)
Refer to Certificate: 5100.08 X
Ex de IIC T6 Ga/Gb (-40 to +70C);
Ex de [ib Gb] [ia Ga] IIC T6 Ga/Gb (-40 to +70C);
Ex de [ia Ga] IIC T6 Ga/Gb (-40 to +70C)
China National Quality Supervision and Test
Center for Explosion Protected Electrical
Products (CQST)
5600 Series Level Transmitter
SPECIAL CONDITIONS FOR SAFE USE (X)
Refer to Certificates:
CNEx09.0324X-5600; CNEx09.0295X-5600;
CNEx09.294X-5600, CNEx08.0092X-5600;
Ex de [ib] [ia] IIC T6 T85C Ta: -40 to +70C; Ex de IIC
T6/DIP A20 T85C Ta: -40 to +70C IP65; Ex de [ia] IIC
T6/DIP A20 T85C Ta:-40 to +70C IP65;Ex nAL IIC T6 Ta:
-40 to +70COverfill Protection
Cert no: Z-65.16-417
U1
26
TV-tested and approved for overfill protection according to
the German WHG regulations
00813-0100-4024, Rev HA
June 2012
Product Data Sheet
00813-0100-4024, Rev HA
June 2012
Rosemount 5600 Series
Dimensional Drawings
FIGURE 1. Cone Antenna Dimensions(1)
FIGURE 2. Extended Cone Antenna Dimensions(1)
7.87 (200)
7.87 (200)
15.75 (400)
3.74 (95) (3 in. Cone)
5.91 (150) (4 in. Cone)
10.24 (260) (6 in. Cone)
14.57 (370) (8 in. Cone)
NOTE:
Other extended cone
lengths are also
available upon request.
Consult factory.
15.75 (400)
19.69 (500)
15 Angle
2.76 (70) (3 in. Cone)
3.66 (93) (4 in. Cone)
5.55 (141) (6 in. Cone)
7.44 (189) (8 in. Cone)
2.76 (70) (3 in. Cone)
3.66 (93) (4 in. Cone)
5.55 (141) (6 in. Cone)
FIGURE 3. Cone Antenna with Integrated
Flushing Connection Dimensions(1)
FIGURE 4. Parabolic Antenna Dimensions(1)
7.87 (200)
7.87 (200)
Connection
for tubing
15.75 (400)
18.11 (460)
5.12 (130) (4 in. Cone)
9.45 (240) (6 in. Cone)
13.98 (355) (8 in. Cone)
3.66 (93) (4 in. Cone)
5.55 (141) (6 in. Cone)
7.44 (189) (8 in. Cone)
6.4 (162)
17.36 (441)
(1) Dimensions are in inches (millimeters)
27
Product Data Sheet
00813-0100-4024, Rev HA
June 2012
Rosemount 5600 Series
FIGURE 5. Process Seal Antenna Dimensions(1)
7.87 (200)
21.65 (550) 4-in. process seal
25.59 (650) 6-in. process seal
6.30 (160) 4-in. process seal
8.58 (218) 6-in. process seal
(1)
Dimensions are in inches (millimeters)
FIGURE 6. Temperature Rating Considerations
O-rings
Flange
Temperature
measured
here
Process Temperature
measured here
NOTE:
Flange temperature depends on mounting conditions, such as
nozzle position, distance to maximum product level, nozzle
height, presence of insulation, etc.
TABLE 15. Flange Temperature Range depending on O-ring selection
O-ring Material
Fluoroelastomer
Ethylene Propylene (EPDM)
Kalrez 6375
Nitrile butadiene
28
Minimum Temperature
F (C) in air
Maximum Temperature
F (C) in air
5 (-15)
-40 (-40)
-4 (-20)
-31 (-35)
392 (200)
266 (130)
527 (275)
230 (110)
Product Data Sheet
00813-0100-4024, Rev HA
June 2012
Rosemount 5600 Series
FIGURE 7. Flange
5 X 45
+20
F1
Area for Marking
Ds1
Dh1
Di1
D1.5
TABLE 16. Dimensions for Stainless Steel Flange are in inches (millimeters)
Flange
Di
Dh
Ds
ANSI 4 inch Class 150
ANSI 6 inch Class 150
DN100 PN16
DN150 PN16
3.78 (96)
4.94 (125.5)
3.78 (96)
4.94 (125.5)
9.02 (229)
10.98 (279)
8.66 (220)
11.22 (285)
7.52 (191)
9.49 (241)
7.09 (180)
9.45 (240)
0.87 (22)
0.87 (22)
0.71 (18)
0.87 (22)
0.94 (23.8)
1.0 (25.4)
0.79 (20.0)
0.87 (22.0)
29
Product Data Sheet
00813-0100-4024, Rev HA
June 2012
Rosemount 5600 Series
Rosemount Level Solutions
Emerson provides a complete range of Rosemount products for level measurement applications.
Vibrating Fork Switches Point Level Detection
Guided Wave Radar Level and Interface Measurement
For high and low alarms, overfill protection, pump control,
including wide pressure and temperature requirements, and
hygienic applications. Flexible mounting. Immune to changing
process conditions and suitable for most liquids.
The product line consists of:
Multivariable, loop-powered Guided Wave Radar transmitters with
a wide range of probe styles to fit different liquids and solids
applications. The product line consists of:
Rosemount 2160 Wireless
Rosemount 2130 Enhanced
Rosemount 5300 Series Accurate, superior performance
transmitter with FOUNDATION fieldbus support
Rosemount 2120 Full-featured
Non-contacting Radar Level Measurement
Rosemount 2110 Compact
The Rosemount non-contacting radar family consists of:
Rosemount 3300 Series Versatile and easy-to-use
transmitter with proven reliability
Pressure Level or Interface Measurement
Rosemount DP Level products are proven, reliable, and can
be used in a variety of applications.
Rosemount 5400 Series Transmitters Loop-powered superior
performance transmitter with a wide range of antennas, for
liquid level measurement in most applications and process
conditions
Electronic Remote Sensors improve control on tall vessels
and distillation towers
Tuned-System Assemblies provide cost-efficient
measurements and improved performance compared to
traditional balanced systems
Rosemount 5600 Series Transmitters Power of 4-wire give
maximum sensitivity and performance for solids, challenging
reactors, rapid level changes and excessive process
conditions.
3051SAL, 3051L, and 2051L Level Transmitters combine
world class pressure instrumentation with direct-mount seals
1199 Seal Systems enable measurements in broad range of
process conditions and applications
Ultrasonic Level Measurement
Chambers for Process Level Instrumentation
Rosemount 9901 chambers for external mounting of process
level measurement and control instrumentation on process
vessels
Global quality assured design and manufacturing
Optimized for Rosemount 3300 and 5300 Series GWR
Top mounted, non-contacting for simple tank and open-air
process level measurements. Unaffected by fluid properties such
as density, viscosity, dirty coating, and corrosiveness.
Intrinsically Safe versions are available for operating in
hazardous areas
Rosemount 3100 Series Ultrasonic Level Transmitters
Rosemount 3490 Series Universal Controllers
Standard Terms and Conditions of Sale can be found at www.rosemount.com\terms_of_sale
The Emerson logo is a trademark and service mark of Emerson Electric Co.
Rosemount and the Rosemount logotype are registered trademarks of Rosemount Inc.
Fisher is a mark owned by Fisher Controls International LLC, a member of the Emerson Process Management business division of Emerson
Electric Co.
PlantWeb is a registered trademark of the Emerson Process Management group of companies.
HART and WirelessHART are registered trademarks of the HART Communication Foundation.
Kalrez is a registered trademark of Du Pont Performance Elastomers.
DeltaV is a trademark of Emerson Process Management group of companies.
Eurofast and Minifast are registered trademarks of Turck Inc.
Masoneilan is a registered trademark of Dresser Inc.
All other marks are the property of their respective owners.
6/12 Rosemount Inc. All rights reserved.
Emerson Process Management
Rosemount Measurement
8200 Market Boulevard
Chanhassen MN 55317 USA
Tel (USA) 1 800 999 9307
Tel (International) +1 952 906 8888
Fax + 1 952 906 8889
00813-0100-4024 Rev HA, 6/12
Europe Process Management
Blegistrasse 23
P.O. Box 1046
CH 6341 Baar
Switzerland
Tel +41 (0) 41 768 6111
Fax +41 (0) 41 768 6300
Emerson FZE
P.O. Box 17033
Jebel Ali Free Zone
Dubai UAE
Tel +971 4 811 8100
Fax +971 4 886 5465
Emerson Process Management Asia
Pacific Pte Ltd
1 Pandan Crescent
Singapore 128461
Tel +65 6777 8211
Fax +65 6777 0947
Service Support Hotline: +65 6770 8711
Email: