Safety Alert - Mismatched Hammer Unions PDF

Download as pdf or txt
Download as pdf or txt
You are on page 1of 8

SAFETY & TECHNICAL ALERT

FLUID CONTROL

Avoiding the Dangers of


Mismatching Hammer Unions
WARNING
To avoid connecting
a wing nut onto an
incompatible female
sub, users must always
assure that these end
connections are positively
identified with identical
size, figure number and
pressure rating.

WARNING
Wing union components
that cannot be positively
identified with regard
to manufacturer 1, size,
figure number, pressure
rating and type of service
3
must never be used.
Incorrectly identified
components will lead to
hazardous assemblies,
which can fail under
pressure and result in
serious personal injury,
death and/or property
damage.

WARNING
Never connect products
with hammer union end
connections that are not
positively identified as to
the manufacturer 1 and
that are not identified
to have identical union
figure number, size
and pressure rating.
Mismatched connections
may fail under pressure,
which can result in
serious personal injury,
death and/or property
damage.

WARNING
If you have any doubts
or questions about
whether you are making
up correct hammer
union connections, never
guess or test. Call FMC
Technologies at the phone
numbers provided at the
end of this document.

We put you first.


And keep you ahead.

Hammer Unions, also called Wing Unions, are


quick make-up and break-out pipe and fitting
connectors that have been used in the oil industry
since the early 1930s. The primary components in
these connectors are a male sub with a spherical
sealing surface, a female sub with external
acme threads, and a wing nut with internal
acme threads to hold the components together.
Depending on size, pressure rating and style,
the assembly may include an elastomeric seal.
One variation of these unions employs separate
load shoulder pieces called segments, which are
required to install the wing nut over the male sub
in some cases.
This bulletin describes general categories of
hammer union connection and component
mismatches. These mismatch conditions are a
result of a failure to positively identify hammer
union connections and components. The potential
for mismatched hammer union connections
and components applies to all manufacturers of
hammer union end connections.

Hammer Union
of combination may, under some circumstances,
appear to seal and may hold the desired amount
of pressure for a period of time. The combination
of 2" Figure 1502 components on the right
illustrates the correct combination showing full
thread engagement.
Other examples of the category:

Following are some categories of potential incorrect


hammer union connections that may result in
hazardous connections. This list does not include
every possible example and is for illustration only.

1-1/2" Figure 600, 602 and 1002 Unions have


the same thread.
5" Figure 400 and 1002 Unions have the
same thread.

Illustration 1

Illustration 2

1. Connecting those products having end


connections of the same size, but different
figure number.
An example of this combination is the 2" Figure
602 and the 2" Figure 1502 Union. The threads on
competitive and older FMC versions of the 2" Figure
602 female sub will slightly engage the internal
threads of the 2" Figure 1502 wing nut, resulting in
an incorrect and hazardous connection.
In illustration (1), the incorrect combination on the
left shows the slight engagement of the female
sub threads and the wing nut threads. This type

2" 602
female
sub (older
version)

2" 1502
male sub
and wing
nut

All 2" 1502


components

SAFETY & TECHNICAL ALERT

FLUID CONTROL

Avoiding the Dangers of


Mismatching Hammer Unions
WARNING
If you have any doubts
or questions about
whether you are making
up correct hammer
union connections, never
guess or test. Call FMC
Technologies at the phone
numbers provided at the
end of this document.

WARNING
Never assemble any
combination of male sub,
wing nut or segments
2
that are not positively
identified to assure that
union figure number,
size, pressure rating
and manufacturer 1 are
identical. Mismatched
components will result in
hazardous connections,
which may fail under
pressure, which can result
in serious personal injury,
death and/or property
damage.

WARNING
The misapplication of
standard, non-detachable
style wing nuts on 2", 3"
and 4" Figure 602 and
1002 detachable nut
connections will result
in an unsafe connection
leading to separation
when under pressure.
Failure to avoid this
condition may result in
death, serious personal
injury and severe property
damage.

2. Connecting those products having different


pressure ratings and having end connections
of the same size and figure number.
Examples of this category:
Figure 1502 (and under) Standard Service
and Sour Gas3 Unions have the same thread.
Products with hammer unions attached by
pipe threads or welding.
To avoid assembling incompatible wing union
components together, users must always assure
that the wing nuts, male subs and segments are
positively identified as being of the same size,
figure number, pressure rating and manufacturer.
Following are some categories of potential
incompatible male sub, wing nut and/or segment
assemblies. This list does not include every
possible example and is for illustration only.
3. Assembly of a wing nut of one size and figure
number onto the male sub of another size or
figure number.
An example of this combination is the assembly
of a 2" Figure 602 standard male sub (nondetachable) installed in a 2" Figure 1502 wing
nut.
In the illustration below left, note the slight
amount of engagement of the male sub in the
wing nut. When installed on a female sub, this
combination may seal and hold the desired
amount of pressure for a period of time. Full
engagement of the correct combination of
components is shown bottom right.

unsafe connection

2" 1502
wing nut

2" 602
standard
male sub

safe connection

We put you first.


And keep you ahead.

4. Assembly of segments and a nut on an


incorrect male sub.
An example of these combinations is a 2"
Figure 602 detachable male sub installed in an
assembly with a 2" Figure 1502 wing nut and
retainer segments.
Since many products are machined integrally
with male subs, it is important to make sure
that the correct union components are used.
The illustration below left shows an incorrect
assembly of 2" Figure 602 and 2" Figure 1502
components. As has been indicated previously, a
combination of this type with a female sub may
seal and hold a desired amount of pressure for
a period of time. The illustration bottom right
shows a correct combination of 2" Figure 602
components.
Following is another category of potential wing
union mismatch that is possible even using
wing union components of the same size, figure
number and manufacturer 1.

unsafe connection

2" 1502
wing
nut and
segments

2" 602
detachable
male sub

safe connection

All 2" 602


components

All 2" 602


components

We put you first.


And keep you ahead.

5. Assembly of Non-detachable Nuts on


Detachable Male Subs

WARNING
The misapplication of
standard, non-detachable
style wing nuts on 2", 3"
and 4" Figure 602 and
1002 detachable nut
connections will result
in an unsafe connection
leading to separation
when under pressure.
Failure to avoid this
condition may result in
death, serious personal
injury and severe property
damage.

An example of these combinations is a 4" Figure


1002 non-detachable nut installed on a 4" Figure
1002 detachable male sub end.
Over the years, FMC Technologies has added
new wing union designs in response to everchanging customer and application requirements.
One of the many innovations introduced by FMC
Technologies was the detachable nut design wing
union in the 1960s. This design was developed
for use on other products such as valves, fittings
and swivel joints with integrally forged end
connections. Since that time, FMC Technologies
has provided both standard, non-detachable (or
captured) nut and detachable nut designs for
Figure 602, 1002 and 1502 wing unions.

Typical nondetachable male sub

Typical nondetachable nut

Wing unions (illustrated top right), which are


manufactured with non-detachable nuts, require
the nut to be assembled to the male sub end
before the subs are assembled by welding
or thread make-up to other equipment. The
detachable nut wing union design (illustrated
below on right) employs a lower profile shoulder
on the male sub end and the addition of retainer
segments that are inserted between the nut and
male sub to retain the nut on the male sub end.
Figure 1502 wing unions employ the same nut
on both detachable and non-detachable nut
designs. The focus of this alert is on sizes 2", 3"
and 4" Figure 602 and 1002 wing unions, which
like the Figure 1502 wing unions are available in
both detachable and non-detachable nut designs.
However, unlike the Figure 1502, these sizes of
Figure 602 and 1002 employ one wing nut for
non-detachable nut connections and another for
detachable nut connections.

Typical detachable
male sub

Typical retainer
segments

Typical detachable
nut

SAFETY & TECHNICAL ALERT

FLUID CONTROL

Avoiding the Dangers of


Mismatching Hammer Unions
WARNING

5. Assembly of Non-detachable Nuts on


Detachable Male Subs (continued)

If you have any doubts


or questions about
whether you are making
up correct hammer
union connections, never
guess or test. Call FMC
Technologies at the phone
numbers provided at the
end of this document.

Normally valves, swivel joints and other service


line equipment using integral wing union end
connections are constructed such that it would
be impossible to capture a non-detachable nut
between the male sub shoulder and the rest of
the product as shown below.

WARNING

In some special situations, such as certain wing


union adapters and assemblies using threaded

The misapplication of
standard, non-detachable
style wing nuts on 2", 3"
and 4" Figure 602 and
1002 detachable nut
connections will result
in an unsafe connection
leading to separation
when under pressure.
Failure to avoid this
condition may result in
death, serious personal
injury and severe property
damage.

Product with
detachable male
sub end

Product with
detachable male
sub end

Detachable nut has


larger ID than male
sub shoulder OD

Non-detachable nut
has smaller ID than
male sub shoulder OD

We put you first.


And keep you ahead.

or butt weld male subs, it is possible to slip the


non-detachable nut from behind a detachable
male sub shoulder (see figure below on left).
On the 3" and 4" sizes of Figure 602 and 1002
wing unions, the annular engagement between
the back of the male sub shoulder and inner
shoulder of the non-detachable nut engages
only slightly - not nearly enough to produce a
safe connection (see figure below on right). This
condition would result in a connection that could
unexpectedly separate under normal operating
conditions.

Typical wing union adapter with 4" 1002


detachable nut male sub end x female
sub end of smaller size

Same adapter with non-detachable


nut inappropriately assembled to male
sub end. Notice the very slight annular
engagement between nut and male sub
shoulder!

We put you first.


And keep you ahead.

To avoid the unsafe condition described on the


previous page, the user must confirm that the
appropriate wing nut is being used for a given
end connection. All 3" and 4" Figure 1002 and
602 detachable nuts currently manufactured by
FMC Technologies have the identifier DET forged
into the back of detachable nuts (see figure
below). On these sizes, if this identifier is not
present, the nut must not be used on detachable

Unlike the 3" and 4" Figure 602 and 1002 wing
unions, the 2" size non-detachable nut does not
engage the male sub shoulder of a detachable
nut connection. However, another issue arises
if a non-detachable nut is used on a detachable
nut connection. On a properly assembled 2" 602
and 1002 detachable nut wing union connection
the nut fully engages the threads of the female
sub (see figure below). Using the shorter non-

WARNING
The misapplication of
standard, non-detachable
style wing nuts on 2", 3"
and 4" Figure 602 and
1002 detachable nut
connections will result
in an unsafe connection
leading to separation
when under pressure.
Failure to avoid this
condition may result in
death, serious personal
injury and severe property
damage.

WARNING

3" 602 detachable


nut with "DET"
identification.

wing union connections. Another obvious


indication of inappropriate use of non-detachable
nuts on detachable wing union connections of
both 3" and 4" Figure 602 and 1002 sizes is the
excessive amount of play between the inside
diameter of the nut shoulder and the outside
diameter of the sub behind the male sub shoulder
(see figure below left). If this condition is ever
encountered, the wing union connection must be
disassembled and investigated for mismatch of
components.

4" 1002 non-detachable nut


inappropriately assembled to a
detached male sub end. Notice
the excessive play between the
ID of the nut and male sub OD
behind the shoulder.

A properly assembled
2" 1002 detachable nut
wing union connection.

detachable nut, which will appear to properly


assemble over the retainer segments of a
detachable male sub end connection, results
in inadequate engagement of the female sub
threads by the nut (see figure bottom right).

Use of non-FMC
manufactured parts
in FMC Technologies
products may result in
death, personal injury or
property damage. The use
of non-FMC parts voids
all design, type, case,
test and quality approvals
by third-party certifying
authorities and may void
product warranty.

This unsafe condition can be encountered on


any product employing detachable male sub
end connections. To avoid this condition, it is
important to ensure the correct nut is used.
Like the 3" and 4" Figure 602 and 1002, the 2"
size also has the identifier DET forged onto
the back of the detachable nut. If the identifier
is not present, the nut must not be used on a
detachable wing union connection.

2" 1002 nondetachable nut


inappropriately used
in a detachable
union assembly.
Notice the resulting
lack of thread
engagement with
the female sub.

SAFETY & TECHNICAL ALERT

FLUID CONTROL

Avoiding the Dangers of


Mismatching Hammer Unions
WARNING
The misapplication of
standard, non-detachable
style wing nuts on 2", 3"
and 4" Figure 602 and
1002 detachable nut
connections will result
in an unsafe connection
leading to separation
when under pressure.
Failure to avoid this
condition may result in
death, serious personal
injury and severe property
damage.

We put you first.


And keep you ahead.

Another way to identify detachable and nondetachable nuts for 2", 3" and 4" sizes of Figure
602 and 1002 wing unions is by their overall
length. The figure below with the accompanying
chart shows how the type of nut can be positively
identified based on a single measurement.
FMC Technologies strongly recommends that,
on locations where both non-detachable and
detachable nut designs of the 2", 3" and 4"
Figure 602 and 1002 wing union connections
are potentially deployed, all personnel be made
aware of this potential safety issue.

WARNING
Do not suspend loads
on service lines using
wing union connections.
Externally applied
bending or tensile loads
are additive to the
loads already induced
by internal pressure.
Externally applied loads
can result in an overstress condition leading
to catastrophic failure. If
externally applied loads
are to be applied, consult
factory for limitations.

NOTES:

1. There are many manufacturers of wing


union assemblies and components that
may represent other possible opportunities
for component mismatch unknown to
FMC Technologies. Specific questions
regarding identification and use of wing
union components not manufactured by
FMC Technologies must be directed to the
appropriate manufacturer.
2. Retainer segments for detachable nut
wing union connections manufactured
by FMC Technologies come in sets of
3. Never put into service detachable
nut wing union connections unless all
segments are in place. Markings on FMC
Technologies hammer union segments
include FMC, part number and material
reference number. For assistance with
positive identification of segments for
appropriate use by size and figure number,
contact FMC Technologies or your nearest
representative.
3. In addition to other identification
markings described in this technical alert,
components intended for sour gas service
are marked SOUR GAS, NACE MR0175
or SG. For SOUR GAS SERVICE, use ONLY
those components that are specifically
identified as being suitable for this service.
Refer to the bulletin NACE MR0175/
ISO 15156 (latest edition) published by
the National Association of Corrosion
Engineers.

WARNING
Never assemble wing
union components
together that are not
positively identified as
to the manufacturer 1,
service and pressure
rating. Failure to do so
can result in a connection
that may fail under
pressure, which can lead
to death, serious personal
injury and severe property
damage.

For Figure Numbers 602 and 1002


Nominal
Size of
Nut (in)

L Dimension
Non-detachable Nuts

Detachable
Nuts

Figure
602

Figure
1002

Figure 602
and 1002

1.91

1.91

2.56

2.06

2.12

2.50

2.25

2.38

3.00

We put you first.


And keep you ahead.

Warnings and Safety Instructions


FMC Technologies cannot anticipate all of the
situations a user may encounter while installing
and using FMC products. Therefore, the user
of FMC products MUST know and follow all
applicable industry specifications and practices
on the safe installation and use of these products.
For additional safety information, refer to FMC
Technologies product catalogs, product brochures
and installation, operating and maintenance
manuals, which can be accessed at www.
fmctechnologies.com/fluidcontrol or contact FMC
Technologies at 800/772-8582.
WARNING
1. Never mix or assemble components, parts
or end connections with different pressure
ratings. Mismatched conditions, including
but not limited to that of a 2" Figure 1502
male sub end connected to a 2" Figure 602
female sub, may fail under pressure resulting
in death, serious personal injury or severe
property damage.
2. Never use or substitute non FMC components
or parts in FMC products or assemblies.
3. Never modify or repair FMC products
in a manner not specifically directed in
instructions published by FMC Technologies.
4. Never strike, tighten, loosen or attempt
repairs on pressurized components or
connections.
5. Never exceed the rated working pressure of
the product.
6. Complete and proper make-up of
components and connections is required
to attain rated working pressure. Always
apply essential care, attention, handling and
inspection to threaded components before,
during and after make-up.
7. Never use severely worn, eroded or corroded
products. Contact FMC Technologies for more
information on how to identify the limits of
erosion and corrosion.

8. Never strike wing union nuts having severely


flattened and extruded ears. This condition
can result in flying debris leading to serious
personal injury and must
9. Always follow safe practices when using
products in overhead applications. Products
not properly secured could fall.
Never exceed the load rating of lifting
devices on products or lifting equipment.
Use of FMC products in suspension
applications can result in over-stress
conditions leading to catastrophic failure.
If externally applied loads are anticipated,
consult factory.
10. Always follow safe practices when manually
lifting and carrying products.
11. Always select only appropriate product and
materials for the intended service:
Never expose standard service products
to sour gas fluids. (Refer to NACE MR0175).
Do not interchange sour gas with standard
service components.
Always use appropriate safety precautions
when working with ferrous products in
below freezing temperatures. Freezing
temperatures lower the impact strength of
ferrous materials.
12. Always follow manufacturers instructions
and Material Safety Data Sheet directions
when using solvents.
13. Always make certain that personnel and
facilities are protected from residual
hazardous fluids before disassembly of any
product.
14. Whenever leakage is detected from FMC
Technologies products, remove them from
service immediately to prevent death,
serious personal injury and/or property
damage.

WARNING
If you have any doubts
or questions about
whether you are making
up correct hammer
union connections, never
guess or test. Call FMC
Technologies at the phone
numbers provided at the
end of this document.

Safety Instructions:
The applications of FMC products are in
working environments and systems which
must be properly designed and controlled.
Safety procedures and policies MUST be clearly
established by the user and followed. Always use
appropriate protective equipment.

SAFETY & TECHNICAL ALERT

FLUID CONTROL

We put you first.


And keep you ahead.

For additional copies of this document, download


PDF at: www.fmctechnologies.com/fluidcontrol.
FMC Technologies, Inc.
500 N Sam Houston Pkwy W Suite 100
Houston TX 77067
P: +1 281.260.2121
FMC Technologies, Inc.
2825 West Washington
Stephenville TX 76401
P: +1 254.968.2181

The specifications contained herein


are subject to change without notice
and any user of said specifications
should verify from the manufacturer
that the specifications are currently in
effect. Otherwise, the manufacturer
assumes no responsibility for the use
of specifications which may have been
changed and are no longer in effect.
DB1_05/21/13

www.fmctechnologies.com
2013 FMC Technologies. All rights reserved.

FMC Technologies
500 N. Sam Houston Pkwy W. Suite 100
Houston, TX 77067
P: 281 260 2121

You might also like