635mld WTP Delhi

Download as pdf or txt
Download as pdf or txt
You are on page 1of 28

HEADWORKS

BIOLOGY
SEPARATION
MEMBRANE
DISINFECTION
BIOSOLIDS
REUSE

Degremont
Water Treatment Technologies &
A Case study of 635MLD WTP at Sonia Vihar- Delhi
presented by

Mukesh GROVER
Chief Technology Officer

HEADWORKS
BIOLOGY
SEPARATION
MEMBRANE
DISINFECTION
BIOSOLIDS
REUSE

Degremont
the Group

a worldwide Group within

Suez Environnement, France,

responsible for Water Treatment,


Design-Build Projects and O&M Services

Slide: 2

HEADWORKS
BIOLOGY
SEPARATION
MEMBRANE
DISINFECTION
BIOSOLIDS
REUSE

Degremont
The Group

70 YEARS
of experience

COMMITTED
TOGETHER

TO WATER,
A SOURCE OF
LIFE
4,400

500

technologies
patented
to date

13.4 m
spent on
R&D in 2009

human resource
base

1,053 m

turnover in 2009

Slide: 3

OVER

HEADWORKS
BIOLOGY
SEPARATION
MEMBRANE
DISINFECTION
BIOSOLIDS
REUSE

Degremont
The Expertise and Experience

1 Billion
people served
by facilities built by
Degrmont

TO WATER,
A SOURCE OF
LIFE

10,000
plants built
worldwide

Slide: 4

COMMITTED
TOGETHER

25.6
million
Inhabitant equivalent
served by wastewater
treatment
facilities
operated by Degrmont

25 million
people served by
drinking water facilities
operated by Degrmont

HEADWORKS
BIOLOGY
SEPARATION
MEMBRANE
DISINFECTION
BIOSOLIDS
REUSE

Degremont
Four key areas of expertise

Water treatment for drinking and industrial use

Sewage/Waste water treatment & recycle


Sludge treatment
Desalination (through Reverse Osmosis)

Slide: 5

HEADWORKS
BIOLOGY
SEPARATION
MEMBRANE
DISINFECTION
BIOSOLIDS
REUSE

Degremont
Strong & committed presence in India

DESIGN AND BUILD PROJECTS

Commissioned Asias largest drinking water filtration plant (1,910 MLD)


at Bhandup-Mumbai, in the year 1981.

Indian subsidiary, since 1986.

Over 300 staff.

Over 150 Water / Waste water treatment installations in India.

OPERATION AND MAINTENANCE - Long term commitment

Slide: 6

16 installations under O & M Service Contract.

2.5 billion litre per day the combined capacity of all treatment
plants under O & M.

1.2 % of population equivalent served in India.

HEADWORKS
BIOLOGY
SEPARATION
MEMBRANE
DISINFECTION
BIOSOLIDS
REUSE

Degremont WTP Major Installations


Strong & committed presence in India

DELHI -SONIA VIHAR

CHENNAI - CHEMBRABKMMJAIPUR - BISALPUR


BANGALORE- TK HALLI KOLKATA - PALTA
NAGPUR -GOREWADA
-

-635 MLD TURBOCIRCULATOR + PULSATOR


+ AQUAZUR V + SLUDGE RECYCLE
530 MLD PULSATOR + AQUAZUR V
400MLD
PULSATOR + AQUAZUR V
400 MLD PULSATOR + AQUAZUR V
270 MLD (3 x 90 MLD) PULSATOR + AQUAZUR V
120 MLD PULSATOR + AQUAZUR V

TRIVANDRUM

74 MLD

PULSATOR + AQUAZUR V

DELHI - WAZIRABAD
DELHI OKHLA

50 MLD
28 MLD

PULSATUBE + Rapid Gravity filters


NITRIFICATION + OZONATION

990MLD
550 MLD
174 MLD

PULSTUBE + AQUAZUR V + SLUDGE RECYCLE


AQUADAF + AQUAZUR V + SLUDGE RECYCLE
PULSATOR + AQUAZUR V

UNDER CONSTRUCTION

BOMBAY(BHANDUP)
BANGALORE- TK HALLI KERALA KOZIKHODE

Slide: 7

HEADWORKS
BIOLOGY
SEPARATION
MEMBRANE
DISINFECTION
BIOSOLIDS
REUSE

Degremont
over 70 years of providing treatment solutions

Degremont Water Clarification Technologies


Turbocirculator
Densadeg
Pulsator
Pulsatube
AquaDAF

Solids contact
High rate solids contact with lamella tube
Pulsating sludge blanket
Pulsating sludge blanket with lamella tubes
Very high rate dissolved air flotation

Water Filteration Technologies

Slide: 8

Aquazur-V

-Rapid Gravity Sand filters

Mediazur

-Dual Media filters

Carbazur

-Activated Carbon filters.

HEADWORKS
BIOLOGY
SEPARATION
MEMBRANE
DISINFECTION
BIOSOLIDS
REUSE

Degremont Clarification Technologies


Typical Clarification Rates and Application

Clarification
Technology

Typical Clarification
Rates (m/hr)

Typical Application

Major Indian
Installations

Turbocirculator

2.0 to 3.5
(upto 5.0 for softening)

Clarification, Presettling, Softening

Delhi, Orissa

Densadeg

10.0 to 20.0
(upto 30 for softening)
(upto 100 for storm
water)

Clarification,
Softening, Storm
water clarification,
Filter Washwater
clarification

Delhi, Bangalore

Pulsator
Pulsatube

2.5 to 4.0
4.0 to 8.0

Clarification

Delhi, Chennai,
Bangalore,
Mumbai,
Kolkatta

AquaDAF

25.0 to 40.0

Clarification
(<50 NTU)

Bangalore

Slide: 9

HEADWORKS
BIOLOGY
SEPARATION
MEMBRANE
DISINFECTION
BIOSOLIDS
REUSE

Turbocirculator Clarifier
High rate solids contact type reactor clarifier

Typical applications:
DW : Clarification, Lime Softening, Pre-settler
WW : Primary & Tertiary Clarification
IWW/PW : Carbonate removal, Metal Precipitation,
Colour removal

Features:
Simple & robust process
Very efficient
Multiple application

Slide: 10

HEADWORKS
BIOLOGY
SEPARATION
MEMBRANE
DISINFECTION
BIOSOLIDS
REUSE

Densadeg Clarifier
Very high rate solids contact type Lamella clarifier

Typical applications:
DW : Clarification, Lime Softening
WW : Primary & Tertiary
Clarification
IWW / PW : Carbonate removal,
Metal Precipitation, Colour removal

Features:
Compact, Versatile & robust
Very efficient, High Quality
Water
Multiple application

Slide: 11

HEADWORKS
BIOLOGY
SEPARATION
MEMBRANE
DISINFECTION
BIOSOLIDS
REUSE

Pulsator Clarifier
Pulsating sludge blanket type clarifier

Typical applications :
Raw Water Clarification (River, Dam, Reservoir)
Clarification of Water with Algae

Features:
Modular & robust process
Rectangular Flat Bottom RCC Tank
No underwater moving parts
Even water distribution over entire bottom

Even sludge withdrawal across the tank


Slide: 12

HEADWORKS
BIOLOGY
SEPARATION
MEMBRANE
DISINFECTION
BIOSOLIDS
REUSE

AquaDAF Water Clarifier


Dissolved Air Flotation process

Typical applications:

Clarification of low turbidity waters


Water with low density solids (i.e. Algae, etc.)
Water with high TOC
Cold waters; Thermal variation
Features:
pretreatment before Membrane filtration
Robust process
Very small footprint
Modular
Polymer not necessary
Operating Principle
Upward floatation with Recycle
stream & micro bubble bed
production.

Slide: 13

HEADWORKS
BIOLOGY
SEPARATION
MEMBRANE
DISINFECTION
BIOSOLIDS
REUSE

AquaDAF Water Clarifier


Internal System (HF Model)
Sludge Channel

Hydraulic Flocculation

Flash Mixer

Compressed
Air

Mobile Weir

Air-Water
Dispersion Zone

Recycled clarified water

Clarified
Water
Channel

Accumulated
Sludge Layer
Sludge

Clarified
Water

Raw water

Coagulated Water Inlet


(after Flash Mixer)
Slide: 14

False Floor
Transition
Zone

Flotation
Zone

HEADWORKS
BIOLOGY
SEPARATION
MEMBRANE
DISINFECTION
BIOSOLIDS
REUSE

AquaDAF Water Clarifier


Advantages

Flexible & Robust :


treats water with temperature >3C
best solution for low turbidity / high algae
raw water
adapts to occasional peaks of TSS or
Turbidity upto 200 NTU.

Cost effective :
Reduction in the time required for the
response to 5 min
Decrease the size of footprint while
retaining its performance.

Easy to operate :
Easy to operate and maintain (very few
mechanicals, no lamella modules, no
clogging)
No need to add material to weigh down the
flocs.
Instantaneous Start and Stop.
Slide: 15

HEADWORKS
BIOLOGY
SEPARATION
MEMBRANE
DISINFECTION
BIOSOLIDS
REUSE

AquaDAF

AquaDAF Clarifier
TK Halli 600MLD WTP, Bangalore - Project Fact Sheet (under
construction)

HF30
28 m3/m2.hr design clarification rate
Flocculation Hydraulic
Hydraulic Desludging by Mobile Weir on clarified water side
Footprint = 4,000 m2 <<< 1/4th of area reqd. by Lamella Clarifier >>>

Slide: 16

Design Performance

AquaDAF Clarifier

Overall Plant

Plant treatment capacity

600 MLD

600 MLD

Raw water quality (turbidity)

20 NTU (90%iles), 100 max.

Water loss

< 2%

Treated water quality


(turbidity)

< 5 NTU (typically< 2 NTU)

< 0.5 NTU

Longer Filter runs

72 hrs (3 days)

HEADWORKS
BIOLOGY
SEPARATION
MEMBRANE
DISINFECTION
BIOSOLIDS
REUSE

Aquzur-V Filter Cross Section

High filtration rates (7 - 15 m/h)


Deep & homogenous filter bed
Uniform feed through V-Channels
In-depth Clogging
Positive Pressure Over Entire Sand Depth
No bed expansion during washing
Surface sweep during washing

Unique Cross-Wash
during Backwash

Advanced
Nozzle Floor
Slide: 17

Uniform Media Size In-depth


filtration, Longer Filter Runs

HEADWORKS
BIOLOGY
SEPARATION
MEMBRANE
DISINFECTION
BIOSOLIDS
REUSE

635 MLD Water Treatment Plant


at Sonia Vihar-Delhi

Delivering the Essentials of Life

HEADWORKS
BIOLOGY
SEPARATION
MEMBRANE
DISINFECTION
BIOSOLIDS
REUSE

635 MLD WTP AT SONIA VIHAR

Contract Particulars

Client : Delhi Jal Board


Contract : Design, Build and 10 years of O&M
Contractor : Consortium of Degrmont France & Degrmont Ltd.

Contract commencement date : December 2000


Construction Completed in : December 2004
Conditions of Contract : EPC/Turnkey Projects, FIDIC First Edition 1999
Contract Value : Rs 189 Crores.

Slide: 19

HEADWORKS
BIOLOGY
SEPARATION
MEMBRANE
DISINFECTION
BIOSOLIDS
REUSE

Slide: 20

635 MLD WTP AT SONIA VIHAR

HEADWORKS
BIOLOGY
SEPARATION
MEMBRANE
DISINFECTION
BIOSOLIDS
REUSE

Slide: 21

PROCESS FLOW CHART

HEADWORKS
BIOLOGY
SEPARATION
MEMBRANE
DISINFECTION
BIOSOLIDS
REUSE

WTP, SONIA VIHAR UNIQUE FEATURES

One of the largest single stage water Treatment Plant projects in India
Caters to a Population of 3.5 Million in Delhi
Fully Automated - SCADA Controlled
Total area - 35 Acres (140,000 Sqm)
Other important units:
3 Major Pump Houses
90 Million Litres of storage in 8 Reservoirs

Total Connected load = 15 MW, Operating Load 6.6 MW


Slide: 22

HEADWORKS
BIOLOGY
SEPARATION
MEMBRANE
DISINFECTION
BIOSOLIDS
REUSE

635 MLD WTP AT SONIA VIHAR

Design Conditions and Constraints

Differing sources of raw water: River Ganges & River Yamuna


Pronounced fluctuations in Water Quality( Range- 25 8,000 NTU)
Water losses restricted to < 1.5%
Treated water quality < 1 NTU ( < 0.4 NTU - 90%ile)

Solution Adopted
Water Line: 3 stage Treatment
Presettler
Pulsator-Pulsating Sludge Blanket Clarifier
Aquazur V : High Rate Gravity Filters

Waste Line: Dewatering of Sludge and Backwash water recovery


Slide: 23

HEADWORKS
BIOLOGY
SEPARATION
MEMBRANE
DISINFECTION
BIOSOLIDS
REUSE

PROJECT MAGNITUDE : AN OVERVIEW


Civil works comprise One Lac cum of Concrete, 25,000 Piles
and 6 Lac cum of earthwork.

20 Km 0f Pipe work which includes 1.7 m dia 2 Kms of MS Pipe


on high rise RCC trestles, 2.0 m dia RCC Pipes & 16 Kms of
internal yard piping laid and tested.

25 large capacity pumps installed in 3 major pump houses with


combined capacity of 1,40,000 Cum/Hr.

3 Substations with total installed capacity of 16 MW.


Over 100 km of cables have been laid.
10 control stations installed shall provide operational flexibility
to access and control any part of the plant.

Slide: 24

HEADWORKS
BIOLOGY
SEPARATION
MEMBRANE
DISINFECTION
BIOSOLIDS
REUSE

635 MLD WTP AT SONIA VIHAR

In operation since October 2006


Consistently producing high quality water.
ISO 14001 & OSHAS 18001 Certified 1st Plant in this sector.

Slide: 25

HEADWORKS
BIOLOGY
SEPARATION
MEMBRANE
DISINFECTION
BIOSOLIDS
REUSE

635 MLD WTP AT SONIA VIHAR

Operation and Maintenance


Contract Value: Rs 7.70 Crore / annum + Escalation
Incentives for extra production & power saving

Heavy penalties for water losses and extra consumption of power


Payment made on monthly basis as per following Formula
Monthly Fee= Fixed Charges+ 0.2388*Quantum of water in Cum, produced
Slide: 26

HEADWORKS
BIOLOGY
SEPARATION
MEMBRANE
DISINFECTION
BIOSOLIDS
REUSE

Plant

MLD

O&M and Power Costs per m3

Technology

O&M Cost
AnnualLacs

Sonia Vihar
Chembarrak
kam

TK Halli

Nagpur

Slide: 27

Rs / m3

Power Cost Lacs

Units/Day

per
Day

Rs/m3

147,320

6.63

1.04

Total
Cost
/m3

Pumping
Stations

1.43

Raw &
Treated Water

635

Pulsator+Aqu
azur

530

Pulsator+Aqu
azur

744

0.39

96,990

4.36

0.82

1.21

Raw &
Treated Water

400

Pulsator+Aqu
azur

312

0.22

8,800

0.40

0.10

0.32

No pumping

120

Pulsator+Aqu
azur

1.43

Treated
Water

876

168

0.38

0.39

27,700

1.25

1.04

HEADWORKS
BIOLOGY
SEPARATION
MEMBRANE
DISINFECTION
BIOSOLIDS
REUSE

NEED OF THE HOUR

Compact Foot-Print
Reliable Technologies
Proven in Indian conditions
Least Energy consumption
Low water losses
Delivering consistent Quality
Water

Committed together to water, a source of


life.
Slide: 28

You might also like