D 3035 - 03 Rdmwmzutmdm
D 3035 - 03 Rdmwmzutmdm
D 3035 - 03 Rdmwmzutmdm
Designation: D 3035 03
1. Scope
1.1 This specification covers polyethylene (PE) pipe made
in thermoplastic pipe dimension ratios based on outside diameter and pressure rated for water (see Appendix X1). Included
are criteria for classifying PE plastic pipe materials and PE
plastic pipe, a system of nomenclature for PE plastic pipe, and
requirements and test methods for materials, workmanship,
dimensions, sustained pressure, burst pressure, and environmental stress cracking. Methods of marking are also given.
1.2 All pipes produced under this specification may be used
for the transport of water, industrial process liquids, effluents,
slurries, municipal sewage, etc. The user should consult the
manufacturer to determine whether the material being transported is compatible with polyethylene pipe and will not affect
the service life beyond limits acceptable to the user.
1.3 The values stated in inch-pound units are to be regarded
as the standard. The values given in parentheses are for
information only.
1.4 The following safety hazards caveat pertains only to the
test methods portion, Section 7, of this specification: This
standard does not purport to address all of the safety concerns,
if any, associated with its use. It is the responsibility of the user
of this standard to establish appropriate safety and health
practices and determine the applicability of regulatory limitations prior to use.
2. Referenced Documents
2.1 ASTM Standards:
D 618 Practice for Conditioning Plastics and Electrical
Insulating Materials for Testing2
D 792 Test Method for Density and Specific Gravity (Relative Density) of Plastics by Displacement3
D 1238 Test Method for Flow Rates of Thermoplastics by
Extrusion Plastometer3
3. Terminology
3.1 DefinitionsDefinitions are in accordance with Terminology F 412, and abbreviations are in accordance with Terminology D 1600, unless otherwise specified.
1
This specification is under the jurisdiction of ASTM Committee F17 on Plastic
Piping Systems and is the direct responsibility of Subcommittee F17.26 on Olefin
Based Pipe.
Current edition approved Sept. 10, 2003. Published November 2003. Originally
approved in 1972. Last previous edition approved 2001 as D 3035 01.
2
Annual Book of ASTM Standards, Vol 08.01.
3
Annual Book of ASTM Standards, Vol 08.03.
Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
NOTICE: This standard has either been superceded and replaced by a new version or discontinued.
Contact ASTM International (www.astm.org) for the latest information.
D 3035 03
manufactured from plastic compounds meeting the material
requirements of this specification and ( 2) the strength and
design requirements are calculated on the same basis as those
used in this specification.
where:
S
=
P
=
D0 =
t
=
R
=
5. Materials
5.1 ClassificationPolyethylene compounds suitable for
use in the manufacture of pipe under this specification shall be
classified in accordance with Specification D 3350 and as
shown in Table 1.
NOTE 1Piping intended for use in the transport of potable water
should be evaluated and certified as safe for this purpose by a testing
agency acceptable to the local health authority. The evaluation should be
in accordance with requirements for chemical extraction, taste, and odor
that are no less restrictive than those included in ANSI/NSF Standard No.
14 or ANSI/NSF Standard No. 61. The seal or mark of the laboratory
making the evaluation should be included on the piping.
NOTE 2Pipe users should consult with the pipe manufacturer about
the outdoor exposure life of the product under consideration.
(1)
5.2 Long-term Property RequirementsPolyethylene compounds suitable for use in the manufacture of pipe under this
specification shall meet or exceed the long-term property
requirements in Table 2.
5.3 HDB ListingPolyethylene compounds suitable for use
in the manufacture of pipe under this specification shall be
listed in PPI TR-4 with HDB ratings in accordance with Table
2.
5.4 Rework MaterialClean, rework material having the
same classification and generated from the manufacturers own
pipe production, may be used by the same manufacturer, as
long as the pipe produced meets all of the requirements of this
specification.
6. Requirements
6.1 WorkmanshipThe pipe shall be homogeneous
throughout and free from visible cracks, holes, foreign inclusions, or other defects. The pipe shall be as uniform as
commercially practicable in color, opacity, density, and other
physical properties.
6.2 Dimensions and Tolerances:
6.2.1 Outside DiametersThe outside diameters and tolerances shall be as shown in Table 3 when measured in
4. Pipe Classification
4.1 GeneralThis specification covers PE pipe made from
three PE plastic pipe materials in various dimension ratios and
water pressure ratings.
4.2 Thermoplastic Pipe Dimension Ratios (DR)This
specification covers PE pipe in various dimension ratios such
as, but not limited to, DR 11, DR 13.5, DR 17, and DR 21. The
pressure rating is uniform for all nominal sizes of pipe for a
given PE pipe material and DR. (See Table X1.1.)
4.3 Special SizesWhere existing system conditions or
special local requirements make other diameters or dimension
ratios necessary, other sizes or dimension ratios, or both, shall
be acceptable in engineered products when mutually agreed
upon by the customer and manufacturer if (1) the pipe is
PE 1404
PE 2406
PE 3408
Physical Property:
Density
Melt Index
Flexural Modulus
Tensile Strength at Yield
Slow Crack Growth Resistance
Hydrostatic Design Basis
Color and UV StabilizerC
1
2
3
1
1A
1
C
Cell Classifications
2
3 or 4
3 or 4
3 or 4
6B
3
C or E
3
3 or 4
4 or 5
4 or 5
6B
4
C or E
7
ISO R 161-1960, Pipes of Plastics Materials for the Transport of Fluids
(Outside Diameters and Nominal Pressure), Part 1, Metric Series.
NOTICE: This standard has either been superceded and replaced by a new version or discontinued.
Contact ASTM International (www.astm.org) for the latest information.
D 3035 03
TABLE 2 Long-Term Property Requirements
PE Material
Designation Code
PE 1404
PE 2406
PE 3408
PE 2406 and PE 3408
A
The hydrostatic design basis shall be established using water or air as the
pressurizing fluid.
Outside Diameter,
in. (mm)
Tolerances,
in. (mm)
1
114
112
2
3
4
6
8
10
12
14
16
18
20
22
24
0.840 (21.34)
1.050 (26.7)
1.315 (33.4)
1.660 (42.2)
1.900 (48.3)
2.375 (60.3)
3.500 (88.9)
4.500 (114.3)
6.625 (168.28)
8.625 (219.08)
10.750 (273.05)
12.750 (323.85)
14.000 (355.60)
16.000 (406.40)
18.000 (457.20)
20.000 (508.00)
22.000 (558.80)
24.000 (609.60)
60.004 (0.10)
60.004 (0.10)
60.005 (0.13)
60.005 (0.13)
60.006 (0.15)
60.006 (0.15)
60.008 (0.20)
60.009 (0.23)
60.011 (0.28)
60.013 (0.33)
60.015 (0.38)
60.017 (0.43)
60.063 (1.60)
60.072 (1.83)
60.081 (2.06)
60.090 (2.29)
60.099 (2.51)
60.108 (2.74)
12
34
7. Test Methods
7.1 ConditioningCondition the test specimens for not less
than 40 h prior to test in accordance with Procedure A of
Practice D 618, for those tests where conditioning is required.
7.2 Test ConditionsConduct tests in the standard laboratory atmosphere of 73 6 3.6F (23 6 2C), unless otherwise
specified in the test methods or in this specification.
7.3 SamplingThe selection of the sample or samples of
pipe shall be as agreed upon by the purchaser and the seller. In
case of no prior agreement, random samples as selected by the
testing laboratory shall be deemed adequate.
7.4 Ambient Temperature Sustained Pressure TestSelect
six specimens of pipe at random and test each specimen
individually with water at controlled temperatures under the
pressures given in Table 6. Each specimen shall be at least ten
times the nominal diameter in length, but not less than 10 in.
(250 mm) or more than 3 ft (1000 mm) between end closures
and containing the permanent marking on the pipe. Condition
the specimens for at least 2 h at 73 6 3.6F (23 6 2C). Test
for the minimum failure time specified in Table 6 in accordance
with Test Method D 1598, at the pressure and temperature
values given in Table 7. Maintain the specimens at the
pressures indicated 610 psi (670 kPa) and the temperatures
specified 6 3.6F (6 2C). Failure of two of the six specimens
tested constitutes failure of the test. Failure of one of the six
specimens tested is cause for retest of six additional specimens.
Failure of one of six specimens tested in retest constitutes
failure in the test. Failure of the pipe test specimen shall be as
defined in Test Method D 1598.
7.5 Elevated Temperature Sustained Pressure TestPrepare
at least three test specimens as specified in 7.4. Using water as
internal medium, test at 176F (80C) and the hoop stress (S)
specified in Table 7 for the given pipe material in accordance
with Test Method D 1598. Two of three specimens must meet
or exceed the specified minimum average failure time.
7.6 Hydrostatic Burst PressureThe test equipment, procedures, and failure definitions shall be as specified in Test
Method D 1599.
7.7 Apparent Ring Tensile Strength at YieldThe method
and test equipment shall be as specified in Test Method D 2290,
Procedure B. Test a minimum of five specimens.
NOTICE: This standard has either been superceded and replaced by a new version or discontinued.
Contact ASTM International (www.astm.org) for the latest information.
D 3035 03
TABLE 4 Wall Thicknesses and TolerancesA for DR-PR PE Plastic Pipe
Nominal
Pipe
Size,
IPS,
in.
1
114
112
2
3
4
5
6
8
10
12
14
16
18
20
22
24
12
34
Nominal
Pipe
Size,
IPS,
in.
1
114
112
2
3
4
5
6
8
10
12
14
16
18
20
22
24
12
34
DR 32.5
Mininum
DR 26
DR 21
DR 17
DR 15.5
Tolerance
Minimum
Tolerance
Minimum
Tolerance
Minimum
Tolerance
Minimum
Tolerance
in.
(mm)
in.
(mm)
in.
(mm)
in.
(mm)
in.
(mm)
in.
(mm)
in.
(mm)
in.
(mm)
in.
(mm)
in.
(mm)
0.062
0.062
0.062
0.062
0.062
0.073
0.108
0.138
0.171
0.204
0.265
0.331
0.392
0.431
0.492
0.554
0.615
0.677
0.738
(1.57)
(1.57)
(1.57)
(1.57)
(1.57)
(1.85)
(2.74)
(3.51)
(4.34)
(5.18)
(6.73)
(8.41)
(9.96)
(10.95)
(12.50)
(14.07)
(15.62)
(16.94)
(18.75)
0.020
0.020
0.020
0.020
0.020
0.020
0.020
0.020
0.021
0.024
0.032
0.040
0.047
0.052
0.059
0.066
0.074
0.081
0.089
(0.51)
(0.51)
(0.51)
(0.51)
(0.51)
(0.51)
(0.51)
(0.51)
(0.53)
(0.61)
(0.81)
(1.02)
(1.19)
(1.32)
(1.50)
(1.68)
(1.88)
(2.06)
(2.26)
0.062
0.062
0.062
0.064
0.073
0.091
0.135
0.173
0.214
0.255
0.332
0.413
0.490
0.538
0.615
0.692
0.769
0.846
0.923
(1.57)
(1.57)
(1.57)
(1.63)
(1.85)
(2.31)
(3.43)
(4.39)
(5.44)
(6.48)
(8.43)
(10.49)
(12.45)
(13.67)
(15.62)
(17.58)
(19.53)
(21.49)
(23.44)
0.020
0.020
0.020
0.020
0.020
0.020
0.020
0.021
0.026
0.031
0.040
0.050
0.059
0.065
0.074
0.083
0.092
0.102
0.111
(0.51)
(0.51)
(0.51)
(0.51)
(0.51)
(0.51)
(0.51)
(0.53)
(0.66)
(0.79)
(1.02)
(1.27)
(1.50)
(1.65)
(1.88)
(2.11)
(2.34)
(2.59)
(2.82)
0.062
0.062
0.063
0.079
0.090
0.113
0.167
0.214
0.265
0.315
0.411
0.512
0.607
0.667
0.762
0.857
0.952
1.048
1.143
(1.57)
(1.57)
(1.60)
(2.01)
(2.29)
(2.87)
(4.24)
(5.44)
(6.73)
(8.00)
(10.44)
(13.00)
(15.42)
(16.94)
(19.35)
(21.77)
(24.18)
(26.62)
(29.03)
0.020
0.020
0.020
0.020
0.020
0.020
0.020
0.026
0.032
0.038
0.049
0.061
0.073
0.080
0.091
0.103
0.114
0.126
0.137
(0.51)
(0.51)
(0.51)
(0.51)
(0.51)
(0.51)
(0.51)
(0.66)
(0.81)
(0.97)
(1.24)
(1.55)
(1.85)
(2.03)
(2.31)
(2.62)
(2.90)
(3.20)
(3.48)
0.062
0.062
0.077
0.098
0.112
0.140
0.206
0.265
0.327
0.390
0.507
0.632
0.750
0.824
0.941
1.059
1.176
1.294
1.412
(1.57)
(1.57)
(1.96)
(2.49)
(2.84)
(3.56)
(5.23)
(6.73)
(8.31)
(9.91)
(12.88)
(16.05)
(19.05)
(20.93)
(23.90)
(26.90)
(29.87)
(32.87)
(35.86)
0.020
0.020
0.020
0.020
0.020
0.020
0.025
0.032
0.039
0.047
0.061
0.076
0.090
0.099
0.113
0.127
0.141
0.155
0.169
(0.51)
(0.51)
(0.51)
(0.51)
(0.51)
(0.51)
(0.64)
(0.81)
(0.99)
(1.19)
(1.55)
(1.93)
(2.29)
(2.51)
(2.87)
(3.23)
(3.58)
(3.94)
(4.29)
0.062
0.068
0.084
0.107
0.123
0.153
0.226
0.290
0.359
0.427
0.556
0.694
0.823
0.903
1.032
1.161
1.290
1.419
1.548
(1.57)
(1.73)
(2.13)
(2.72)
(3.12)
(3.89)
(5.74)
(7.37)
(9.12)
(10.85)
(14.12)
(17.63)
(20.90)
(22.94)
(26.21)
(29.49)
(32.77)
(36.04)
(39.32)
0.020
0.020
0.020
0.020
0.020
0.020
0.027
0.035
0.043
0.051
0.067
0.083
0.099
0.108
0.124
0.139
0.155
0.170
0.186
(0.51)
(0.51)
(0.51)
(0.51)
(0.51)
(0.51)
(0.69)
(0.89)
(1.09)
(1.30)
(1.70)
(2.11)
(2.51)
(2.74)
(3.15)
(3.53)
(3.94)
(4.32)
(4.72)
DR 13.5
Mininum
DR 11
DR 9.3
DR 9
DR 7
Tolerance
Minimum
Tolerance
Minimum
Tolerance
Minimum
Tolerance
Minimum
in.
(mm)
in.
(mm)
in.
(mm)
in.
(mm)
in.
(mm)
in.
(mm)
in.
(mm)
in.
(mm)
in.
(mm)
0.062
0.078
0.097
0.123
0.141
0.176
0.259
0.333
0.412
0.491
0.639
0.796
0.944
1.037
1.185
1.333
1.481
1.630
1.778
(1.57)
(1.98)
(2.46)
(3.12)
(3.58)
(4.47)
(6.58)
(8.46)
(10.46)
(12.47)
(16.23)
(20.22)
(23.98)
(26.34)
(30.10)
(33.86)
(37.62)
(41.40)
(45.16)
0.020
0.020
0.020
0.020
0.020
0.021
0.031
0.040
0.049
0.059
0.077
0.096
0.113
0.124
0.142
0.160
0.178
0.196
0.213
(0.51)
(0.51)
(0.51)
(0.51)
(0.51)
(0.53)
(0.79)
(1.02)
(1.24)
(1.50)
(1.96)
(2.44)
(2.87)
(3.15)
(3.61)
(4.06)
(4.52)
(4.98)
(5.41)
0.076
0.095
0.120
0.151
0.173
0.216
0.318
0.409
0.506
0.602
0.784
0.977
1.159
1.273
1.455
1.636
1.818
2.000
2.182
(1.93)
(2.41)
(3.05)
(3.84)
(4.39)
(5.49)
(8.08)
(10.39)
(12.85)
(15.29)
(19.91)
(24.82)
(29.44)
(32.33)
(36.96)
(41.55)
(46.18)
(50.80)
(55.42)
0.020
0.020
0.020
0.020
0.021
0.026
0.038
0.049
0.061
0.072
0.094
0.117
0.139
0.153
0.175
0.196
0.218
0.240
0.262
(0.51)
(0.51)
(0.51)
(0.51)
(0.53)
(0.66)
(0.97)
(1.24)
(1.55)
(1.83)
(2.39)
(2.97)
(3.53)
(3.89)
(4.45)
(4.98)
(5.54)
(6.10)
(6.65)
0.090
0.113
0.141
0.178
0.204
0.255
0.376
0.484
0.598
0.712
0.927
1.156
1.371
1.505
1.720
1.935
2.151
2.366
2.581
(2.29)
(2.87)
(3.58)
(4.52)
(5.18)
(6.48)
(9.55)
(12.29)
(15.19)
(18.08)
(23.55)
(29.36)
(34.82)
(38.23)
(43.69)
(49.15)
(54.64)
(60.10)
(65.56)
0.020
0.020
0.020
0.021
0.024
0.031
0.045
0.058
0.072
0.085
0.111
0.139
0.165
0.181
0.206
0.232
0.258
0.284
0.310
(0.51)
(0.51)
(0.51)
(0.53)
(0.61)
(0.79)
(1.14)
(1.47)
(1.83)
(2.16)
(2.82)
(3.53)
(4.19)
(4.60)
(5.23)
(5.89)
(6.55)
(7.21)
(7.87)
0.093
0.117
0.146
0.184
0.211
0.264
0.389
0.500
0.618
0.736
0.958
1.194
1.417
1.556
1.778
2.000
2.222
2.444
2.667
(2.36)
(2.97)
(3.71)
(4.67)
(5.36)
(6.71)
(9.88)
(12.70)
(15.70)
(18.69)
(24.33)
(30.33)
(35.99)
(39.52)
(45.16)
(50.80)
(56.44)
(62.08)
(67.74)
0.020
0.020
0.020
0.022
0.025
0.032
0.047
0.060
0.074
0.088
0.115
0.143
0.170
0.187
0.213
0.240
0.267
0.293
0.320
(0.51)
(0.51)
(0.51)
(0.56)
(0.64)
(0.81)
(1.19)
(1.52)
(1.88)
(2.24)
(2.92)
(3.63)
(4.32)
(4.75)
(5.41)
(6.10)
(6.78)
(7.44)
(8.13)
0.120
0.150
0.188
0.237
0.271
0.339
0.500
0.643
0.795
0.946
1.232
1.536
1.821
2.000
2.286
2.571
2.857
3.143
3.429
(3.05)
(3.81)
(4.78)
(6.02)
(6.88)
(8.61)
(12.70)
(16.33)
(20.19)
(24.03)
(31.29)
(39.01)
(46.25)
(50.80)
(58.06)
(65.30)
(72.57)
(79.83)
(87.10)
Tolerance
in.
(mm)
0.020 (0.51)
0.020 (0.51)
0.023 (0.58)
0.028 (0.71)
0.033 (0.84)
0.041 (1.04)
0.060 (1.52)
0.077 (1.96)
0.095 (2.41)
0.114 (2.90)
0.147 (3.73)
0.184 (4.67)
0.219 (5.56)
0.240 (6.10)
0.274 (6.96)
0.309 (7.85)
0.343 (8.71)
0.377 (9.58)
0.411 (10.44)
A
The minimum is the lowest wall thickness of the pipe allowable at any cross section. The maximum permitted wall thickness, at any cross section, is the minimum wall
thickness plus the stated tolerance. All tolerances are on the plus side of the minimum requirement.
9. Marking
9.1 Marking on the pipe shall include the following, spaced
at intervals of not more than 5 ft (1.5 m):
9.1.1 Nominal pipe size (for example, 2 in. IPS),
9.1.2 Type of plastic pipe material in accordance with the
designation code given in 3.2.5 (for example, PE3408),
NOTICE: This standard has either been superceded and replaced by a new version or discontinued.
Contact ASTM International (www.astm.org) for the latest information.
D 3035 03
TABLE 5 Burst Pressure Requirements for Water at 73F (23C)
for DR-PR PE Plastic Pipe
7
9
9.3
11
13.5
15.5
17
21
26
32.5
A
PE 2406
PE 3408
Material
PE 3408 and PE 2406
PE 1404
PE 1404
psi
(MPa)
psi
(MPa)
840
630
607
504
403
348
315
252
202
160
(5.79)
(4.34)
(4.19)
(3.47)
(2.78)
(2.40)
(2.13)
(1.74)
(1.39)
(1.10)
417
313
301
250
200
172
156
125
100
79
(2.87)
(2.16)
(2.08)
(1.72)
(1.38)
(1.19)
(1.08)
(0.86)
(0.69)
(0.55)
(MPa)
(17.37)
(8.62)
The fiber stresses used to derive these test pressures are as follows:
psi
2520
1250
psi
2520
1250
(MPa)
(17.37)
(8.62)
NOTICE: This standard has either been superceded and replaced by a new version or discontinued.
Contact ASTM International (www.astm.org) for the latest information.
D 3035 03
TABLE 7 Sustained Pressure Test Conditions, Requirements and PressuresA
Minimum Hours Before Failure at 73F (23C)
Pipe
Material
PE 1404
PE 2406
PE 3408
S = 1600 psi
(11 MPa)
S = 1320 psi
(9.1 MPa)
S = 800 psi
(5.5 MPa)
S = 725 psi
(5 MPa)
S = 580 psi
(4 MPa)
S = 435 psi
(3 MPa)
80
150
150
150
60
60
1000
1000
1000
Dimension Ratio
Material
Temperature,
F (C)
Stress, S,
psi (MPa)
9.3
11
13.5
15.5
17
21
26
32.5
80
(0.55)
58
(0.40)
44
(0.30)
132
(0.91)
73
(0.50)
58
(0.40)
160
(1.10)
73
(0.50)
58
(0.40)
64
(0.44)
46
(0.32)
35
(0.24)
106
(0.73)
58
(0.40)
46
(0.32)
128
(0.88)
58
(0.40)
46
(0.32)
51
(0.35)
37
(0.26)
28
(0.19)
84
(0.58)
46
(0.32)
37
(0.26)
102
(0.70)
46
(0.32)
37
(0.26)
PE 2406
PE 3408
73 (23)
800 (5.5)
176 (80)
580 (4)
176 (80)
435 (3)
73 (23)
1320 (9.1)
176 (80)
725 (5)
176 (80)
580 (4)
73 (23)
1600 (11)
176 (80)
725 (5)
176 (80)
580 (4)
267
(1.84)
193
(1.33)
145
(1.00)
440
(3.03)
242
(1.67)
193
(1.33)
533
(3.68)
242
(1.67)
193
(1.33)
200
(1.38)
145
(1.00)
108
(0.75)
330
(2.28)
181
(1.25)
145
(1.00)
400
(2.76)
181
(1.25)
145
(1.00)
193
(1.33)
140
(0.97)
105
(0.72)
318
(2.19)
175
(1.21)
140
(0.97)
386
(2.66)
175
(1.21)
140
(0.97)
160
(1.10)
116
(0.80)
87
(0.60)
264
(1.82)
145
(1.00)
116
(0.80)
320
(2.21)
145
(1.00)
116
(0.80)
128
(0.88)
93
(0.64)
70
(0.48)
211
(1.46)
116
(0.80)
93
(0.64)
256
(1.77)
116
(0.80)
93
(0.64)
110
(0.76)
80
(0.55)
60
(0.41)
182
(1.26)
100
(0.69)
80
(0.55)
221
(1.52)
100
(0.69)
80
(0.55)
100
(0.69)
73
(0.50)
54
(0.38)
165
(1.14)
91
(0.63)
73
(0.50)
200
(1.38)
91
(0.63)
73
(0.50)
P5D
t 21
where:
P
=
S
=
Do =
t
=
SUPPLEMENTARY REQUIREMENTS
POTABLE WATER REQUIREMENT
This requirement applies whenever a Regulatory Authority or user calls for product to be used to
convey or to be in contact with potable water.
S1. Potable Water RequirementProducts intended for
contact with potable water shall be evaluated, tested and
certified for conformance with ANSI/NSF Standard No. 61
NOTICE: This standard has either been superceded and replaced by a new version or discontinued.
Contact ASTM International (www.astm.org) for the latest information.
D 3035 03
APPENDIX
(Nonmandatory Information)
X1. PIPE PRESSURE RATINGS
TABLE X1.1 Thermoplastic Pipe Dimension Ratios (DR) and Water Pressure Ratings (PR) at 73F (23C) for DR-PR PE Plastic Pipe
PE Pipe MaterialsA
Dimension
Ratio
PE 3408
PE 2406
PE 1404
267
200
193
160
128
110
100
80
64
51
(1.84)
(1.38)
(1.33)
(1.10)
(0.88)
(0.76)
(0.69)
(0.55)
(0.44)
(0.35)
210
158
152
126
100
87
79
63
50
40
(1.45)
(1.09)
(1.05)
(0.87)
(0.69)
(0.60)
(0.54)
(0.43)
(0.34)
(0.28)
133
100
96
80
64
55
50
40
32
25
(0.92)
(0.69)
(0.66)
(0.55)
(0.44)
(0.38)
(0.34)
(0.28)
(0.22)
(0.17)
A
See 3.2.5 for code designations. Pressure ratings determined using 0.50 design factor. Other design factors may be appropriate under certain conditions. See PPI
TR-9.
X1.1 The pipe is rated for use with water at 73F (23C) at
the maximum internal pressures shown in Table X1.1. Lower
pressure ratings than those calculated in accordance with 3.2.3
may be recommended by the pipe manufacturer where pressure
surges, elevated temperatures, or unusual installation conditions exist. Experience of the industry indicates that PE plastic
pipe meeting the requirements of this specification gives
satisfactory service under normal conditions for a long period
ASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentioned
in this standard. Users of this standard are expressly advised that determination of the validity of any such patent rights, and the risk
of infringement of such rights, are entirely their own responsibility.
This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years and
if not revised, either reapproved or withdrawn. Your comments are invited either for revision of this standard or for additional standards
and should be addressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of the
responsible technical committee, which you may attend. If you feel that your comments have not received a fair hearing you should
make your views known to the ASTM Committee on Standards, at the address shown below.
This standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,
United States. Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the above
address or at 610-832-9585 (phone), 610-832-9555 (fax), or [email protected] (e-mail); or through the ASTM website
(www.astm.org).