9.SOP Barring Gear or Turning Gear

Download as doc, pdf, or txt
Download as doc, pdf, or txt
You are on page 1of 5

Turning Gear

Operation Procedure
Page 1 of 5

Work Instruction
G1-7013

Revision no.

Prepared by
Reviewed by
Approved by

Revision : 00
Date :

Effective date

Issue no.

DCC

Signature

Name Surname

Date

Guruh Iriyanto

18/05/2015

Turning Gear
Operation Procedure
Page 2 of 5
REVISION HISTORY

Rev.

Effective date

00

Revision : 00
Date :

Description of Revision
Initial Issue

Prepared

Reviewed

Approved

Turning Gear
Operation Procedure
Page 3 of 5

ENGLISH

BAHASA INDONESIA

1.

UNIT
Utility

1.

UNIT
Utility

2.

SYSTEM
Turbine

2.

SISTIM
Turbin

3.

SAFETY
Ensure all permits are signed off

3.

KESELAMATAN
Pastikan semua

ijin

kerja

sudah

ditandatangani

4.

Ensure Operator is wearing


recommended PPE

Pastikan operator menggunakan PPE

Ensure All Equipment in good condition


and ready to start

Semua Equipment dalam kondisi siap

TURNING GEAR G1-7013 START UP


PROCEDURE
Preparation:
Ensure electrical power sources for
turning gear available
Ensure Auxiliary Oil Pump G1-7011 has
been running
Ensure Jacking Oil Pump G1-7012has
been running
Ensure Speed 0 Rpm

Revision : 00
Date :

yang disarankan
untuk dijalankan.
4.

PROSEDUR START TURNING GEAR


G1-7013
Tahap Persiapan:
Pastikan Source power untuk turning gear
sudah tersedia
Pastikan Auxiliary Oil Pump G1-7011
sudah beroperasi
Pastikan Jaacking oil Pump G1-7012
sudah beroperasi
Pastikan putaran rotor/speed 0 Rpm

Turning Gear
Operation Procedure
Page 4 of 5

BAHASA INDONESIA
ENGLISH
Pastikan Kondisi di sekitar equipment ter
Ensure around the equipment is free

bebas dari gangguan


Pastikan valve inlet dan outlet sudah

Ensure inlet and outlet valve open

terbuka
Start Turning Gear G1-7013

Start Turning Gear G1-7013


Pindahkan Switch On/Off pada Panel
Change the Switch ON/OFF at
panel into ON Position
Spin up the turning gear G1-7013
hand wheel until engaged condition
Turn on/Push the Start Push button at
turning Gear G1-7013 panel
Ensure turning gear motor G1-7013
running and light indicator on
Ensure rotor speed 1.5 Rpm (Rolling)

ke posisi On
Putar hand wheel turning gear G1-7013
sampai Engaged
Tekan tombol start pada panel Turning
gear G1-7013
Pastikan motor turning gear G1-7013
running dan lampu pada panel menyala
Pastikan rotor berputar serta speed 1.5
rpm
Pastikan Turning Gear G1-7013 bekerja

Ensure Turning gear G1-7013 running


in normal condition, and there are no
abnormality such as noise or friction

Revision : 00
Date :

dalam

kondisi

normal

tidak

abnormality baik suara akibat gesekan

ada

Turning Gear
Operation Procedure
Page 5 of 5

ENGLISH
STOP TURNING GEAR G1-7013
Push/select the Stop push button at
turning gear G17013 panel
Ensure turning gear motor G1-7013
stop
Ensure light indicator Off
Ensure rotor stop (0 Rpm)

Revision : 00
Date :

BAHASA INDONESIA
STOP TURNING GEAR G1-7013
Tekan tombol Stop pada panel turning
gear G1-7013
Pastikan motor turning gear G1-7013
berhenti
Pastikan lampu indicator stop turning
gear G1-7013 menyala
Pastikan rotor berhenti (0 Rpm)

You might also like