Specification
GS 80B80M01E 11th
EML500 series
EML500
Electromagnetic Log
General
The EML500 series electromagnetic log confirms to the
technical requirements for the performance standard
determined by IMO Resolution A824(19) and MSC.96(72) also
meet type approval issued by the Transport Ministry of JG
Features
1) Small size and light weight compared ordinary models.
2) The length of cable between the sensor and the master unit
can be extended maximum 300m by adoption of the
preamplifier built .
3) Full provision of various external interfaces
- Pulse output (Photo coupler / contact)
- Digital signal (NMEA0183)
- Analog signal (0V to 5V DC / 0A to 20mA)
- Alarm contact output and Digital I/F form GPS
4) Reduction in the number of parts by employment of highly
integrated circuits including microprocessor, and has no
moving parts, thereby achieving high reliability.
5) Provision of small size and light weight master indicator for
indication of speed and distance, and can be operated by the
master indicator. Milepost calibration etc., thereby,
installation place of master indicator is not limited.
6) Variety of sensors available to meet various instillation
requirements. A dual-axis sensor can measure not only the
longitudinal, speed but also the transverse speed.
7) Built-in self-diagnostic function.
8) All indicators can be driven by input signal (NMEA0183) from
GPS.
General specification
- Measurement subject : Ships water speed and distance
- Measurement principle : Faradays law of
electromagnetic induction
Performance specification
- Measurement range
Speed
: -4kt to +20kt (Note 1
-5kt to +25kt (Note 1
-7kt to +35kt
-8kt to +40kt
-10kt to +50kt (Note 2
-13kt to +65kt (Note 2
(Note 1 MED is attended in case of Single-axis system (range
of -4kn to 20kn or -5kn to 25kn).
(Note 2 Additional engineering is required concerning the
installation of the sensor.
Trance verse speed : 0kt to 6.5kt (for Dual-axis)
Distance : 0nm to 9999.99nm
2004.10
2004.11
2006.04
9th (YDK)
10th (YDK)
11th(YDK)
GS 80B80M01E
1998.03
6th (YDK)
2002.12
7th (YDK)
2004.05
8th (YDK)
2
Environmental conditions
- Ambient temperature operating
-15 to +55
- Humidity
- Vibration
5 to 12.5Hz 1.6mm
12.5 to
- Insulation resistance :
25Hz 0.38mm
25 to
50Hz 0.1mm
- Withstanding voltage
Master indicator
(LR523)
Assist Monitor
(MHR112)
(Option)
Dimmer box
(LD001A)
Dimmer box
(MKD002)
Master unit
(LT501)
GPS
Ships Speed
NMEA0183
MKD002
Dimmer box
or
VDR
ECDIS
Junction box
(LN052)
RADAR etc.
ARPA
GYRO COMPASS
AUTO PILOT
INS
RADAR
True wind direction
and speed indicator
EML500-HD1 (Single-axis)
EML500-HS1 (Sigle-axis)
Protective pipe
(LV905)
Lower flange
(LV904)
EML500-HV1/HV2
(Single / Dual axis)
70F Single-bottom type
EML500-FA1/FA2
(Single / dual axis)
48F Single-bottom type
GS80B80M01E 11th
2006-04
3
Component models of EML500
EML500 is composed of Master unit, Master indicator and Sea-bottom (with sensor).
And if it is necessary, combined with speed indicator and environ equipments.
Component Models :
Sensor unit code
System Type
Product Name and Model
Master unit
LT501
Master indicator
LR523
LR524
LR525
LD001A
LN052
LS531
Dimmer box
Junction box
LS501
LS571
Sensor
LS541
70 sensor (Single-axis)
48 sensor (Single-axis)
LS542
LS572
Sensor cable
LS503
70 sensor (Dual-axis)
LV071A
Seawater valve
For sensors 35
LV052
For sensors 70
LV031
Seawater valve flange
Protection tube
48 sensor (Dual-axis)
LS591
LV033
Sensor unit
LS592
Rodmeter
For sensors 48
For sensors 35
LV904
LV905
LV903
LV902
Mounting
plate for
seawater
valve
LV902A1
LV902A2
LV902A3
LV902A4
LV902A5
LV910
LV9012
Zinc plate
LV9013
Installation
type
Sensor
LV9011
installation
Standard length
of protrusion
(Note)
(Note)
Singlebottom
Doublebottom
Singlebottom
Singlebottom
Singlebottom
Singlebottom
50mm
50mm
7mm
or
57mm
13mm
or
73mm
7mm
or
57mm
13mm
or
73mm
Note : Items marked with a are ordered from the shipbuilder as standard.
GS80B80M01E 11th
2006-04
4
Engineering specification
- Analog speed signal : Current output (4 circuit)
- Power
100V to 115V AC or
200V to 230V AC 10% 50/60Hz 6%
(Selectable by the jumper setting in the power supply unit)
- Power consumption
80VA
- Input signal
- Input the detected voltage at sensor
0.242mA/knot (from sensor)
- Input from GPS (for back-up by GPS)
Data format of GPS input can be set by Master indicator.
Connection units
: Start bit
Data bit
Stop bit
Parity
1 bit
8 bit
1 bit
None
Capacity
Data format
Recommend format : based on IEC61162-1, VTG,
VBW, VHW and etc...
Header character
: 6 ASCII letter
(Example : $GPVTG and etc...)
Input circuit
: Photo coupler
- Output signal
- Analog speed signal : Voltage output (2 circuit)
Output level : Select able from 0V to 5V or 1V to 5V
: 4800bps
GS80B80M01E 11th
2006-04
5
- Data format (based on NMEA0183)
( EM.Log Software version : P )
Output sentence is possible changing by DIP SW.
<NMEA Ver 2.0 setting : Normally setting>
0.00kt to 65kt
0.00km/h to 120.38km/h
VBW sentence
VLW sentence
0.00nm to 9999.99nm
0.00nm to 9999.99nm
- Checksum
Checksum is the 8-bit exclusive-OR (no start or stop bits)
of all characters in the sentence, including , delimiters,
but not including the $ and the * delimiters.
- Range of data
Water speed :
-13.00kt to 65kt
Ground speed :
0.00kt to 99.9kt
VHW sentence
GS80B80M01E 11th
2006-04
6
<NMEA Ver 2.3 setting>
4) When the ROM/RAM error is detected
VBW sentence
0.00kt to 65kt
Ground speed :
0.00kt to 99.90kt
0.00km/h to 120.38km/h
0.00km/h to 185.01km/h
Data block format
VLW sentence
1) for single-axis
2) for dual-axis
1) at normal operation
-13.00kt to 65kt
Ground speed :
0.00kt to 99.9kt
VHW sentence
0.00nm to 9999.99nm
0.00nm to 9999.99nm
- Checksum
Checksum is the 8-bit exclusive-OR (no start or stop bits)
of all characters in the sentence, including , delimiters,
but not including the $ and the * delimiters.
- Speed limit output (2 circuits)
Contact : At state of speed limit
Close (standard)
At state of speed limit
Open
(Selectable by Dip.SW 9-2(off: close, on: open))
Capacity : Rate loads
30V DC, 1A
(resistance load)
30V AC, 0.5A
Minimum appliciate load 10mV DC, 10A
Chattering
1msec max.
Setting
: The higher or lower speed limit can be set by
Master indicator.
- Alarm contact output (2 circuits)
Contact : At abnormal
Close (standard)
At abnormal
Open
(Selectable by Dip.SW 9-3(off: close, on: open))
Capacity : Rate loads
30V DC, 1A
(resistance load)
30V AC, 0.5A
Minimum appliciate load 10mV DC, 10A
Chattering
1msec max.
Failure alarm - ROM/RAM error
- Low battery (less than 2.1V)
- A/D converter error
- GPS input error
- Communication error between Master unit
and Master indicator.
GS80B80M01E 11th
2006-04
7
Comportment equipment specification
- Master unit LT501
Receives and converters speed data signals from the
sensor. Then transmits the speed and distance to external
devices in various signal forms.
- Wiring position : Coaming of under or back
- Installation
: Wall or flush mounted type
- Master indicator LR523
Receives digital signals from the master unit, and displays
the speed and distance. Both the display and operation
panel are on the front of the master indicator. Set data are
sent to the master unit in the form of digital signals, and
placed in the memory.
- Display function
The speed and distance are displayed with digital by LED
indicator.
1) Indicate of the Speed and Distance
Speed
: (-)kt
Distance
: nm
2) Indicate of the trip distance
Trip distance : nm
3) Indication of the longitudinal transverse speed
(for dual-axis)
longitudinal speed : (-)kt
Transverse speed : S/Pkt
4) Indicating of the resultant speed and detection
(for dual-axis)
Resultant speed : (-)kt
Direction
- Input signal
: Digital signal(NMEA0183)
by
buttons.
- Construction
Sea-bottom (Sensor)
- HS1 type
- HD1 type
- FA1/FA2 type
- HV1/HV2 type
: Wall mount
- Wiring position
GS80B80M01E 11th
2006-04
8
Outline and Type No. and Suffix code
Master indicator (Wall mount)
LR523-W-1-
24V
GND
FG
RDA
RDB
SDA
SDB
N.C
1
2
3
4
5
6
7
8
GS80B80M01E 11th
2006-04
9
Master unit (Wall mount)
LT501-W-
Terminal drawing
LT501-F-
GS80B80M01E 11th
2006-04
10
Master unitLT501-X1 X7/Option
Type No.
Suffix code
LT501
For EML500
Style
Flush mount
Wall mount
Single-axis
System
Ships power
Measurement range
Color
Name plate
Option
Note
LR524-W--
Single-axis
Dual-axis (Note 1)
100V AC 50/60Hz 1
110V AC 50/60Hz 1
115V AC 50/60Hz 1
200V AC 50/60Hz 1
220V AC 50/60Hz 1
to
to
to
to
to (Note 2)
to (Note 2)
JG / Japanese
None / English
Munsell 2.5G7/2
Munsell 7.5BG7/2
Analog output
Analog output
(Note 1) In case of dual-axis, transverse speed may not be able to the mounting
position of sensor.
(Note 2) About 50/60kt correspondence, additional engineering is required concerning
the installation of the sensor.
(Note 3) MED is attended in case of System X2 = 1 (Single-axis) and X4 = 1
(-4kn to 20kn) or X4 = 2 (-5kn to 25kn)
(Note 4) Please append external speed signal (NMEA0183) format with order sheet.
GS80B80M01E 11th
2006-04
11
Analog indicator (Wall mount)
LR525-W--
- Dual :
resultant speed /direction
- Dual :
longitudinal / transverse speed
Type No.
Suffix code
Note
LR524
Style
Flush mount
Wiring position
Measurement range
LR525-F--
(Power supply 200V to 230VAC)
Dual-axis
Illumination
to
to
to
to
to
to
(Note 2)
(Note 2)
External/LED illumination
JG / Japanese
None / English
Color
Name plate
Option
Munsell 2.5G7/2
Munsell 7.5BG7/2
(Note 1) X2 = 2 Grand is use for Wall mount only. (15b, 20c each 1 use)
(Note 2) X5 = 2 and X5 = 4 are use for LR524 built-in dimmer unit only.
(Note 3) MED is attended in case of X3 = 1 (-4kn to 20kn) or X3 = 2 (-5kn to 25kn)
GS80B80M01E 11th
2006-04
12
Junction box
LN052-W-
A
XSPD B
GND-S E
G
+15V C
-15V D
24V-S F
GS80B80M01E 11th
2006-04
13
Dimmer box (Flash mount type)
Dimmer switch
LD001A-F-
LD002-A1
GS80B80M01E 11th
2006-04