Bejan Gabriel
Project name : Platforma de depozitare
Project reference :
ArcelorMittal Beams Calculator v3.21
Beam reference :
Preliminary Design Note
DATA
General parameters
COMPOSITE BEAM
Main span
6.000 m
Width on the left
L1 =
1.300 m
Max. participating width
L1 =
0.650 m
Width on the right
L2 =
1.300 m
Max. participating width
L2 =
0.650 m
Intermediate beam
Slab
Total thickness = 13.00 cm
Slab with profiled sheeting
Profiled steel sheeting '''' , perpendicular to the beam
(h = 50.0 mm ; e = 305.0 mm ; b1 = 137.0 mm ; b2 = 175.0 mm ; t = 0.8 mm ;
2
2
fy = 320 N/mm ; M = 0.00 kg/m )
Section
IPE 220 - S275 JR/J0/J2
ht
bf
tw
tf
r
=
=
=
=
=
= 210000 N/mm
3
=
7850 kg/m
220.0 mm
110.0 mm
5.9 mm
9.2 mm
12.0 mm
A
Av
Iy
Iz
It
Iw
Wel.y
Wpl.y
=
=
=
=
=
=
=
=
33.37 cm
2
15.88 cm
4
2771.84 cm
4
204.89 cm
4
9.07 cm
6
22672.31 cm
3
251.99 cm
3
285.41 cm
Materials
Steel
Steel grade S275 JR/J0/J2 - Reduction of fy with thickness according to EC3
Databases 2015_01
Flanges
Web
Section
fyf
275 N/mm
fyw =
275 N/mm
fy
275 N/mm
2
2
0.924
Concrete slab C30/37
2
fck =
30 N/mm
Ecm =
32837 N/mm
Modular ratio for LONG TERM
Ceq =
21.42
Modular ratio for SHORT TERM
Ceq =
6.40
Software use conditions apply
User's name : B.Gabriel
Date : 13/01/2016
Page 1 / 12
Bejan Gabriel
Project name : Platforma de depozitare
Project reference :
ArcelorMittal Beams Calculator v3.21
Beam reference :
-6
Shrinkage (R) - Long term
Density of the concrete (slab)
Reinforcement steel
fyk =
Connection
Connectors TRW Nelson KB 3/4"-100
h
fy
fu
Main span
= 300.10
25.00 kN/m
=
=
=
=
500 N/mm
19.0 mm
100.0 mm
2
350.0 N/mm
2
450.0 N/mm
L = 6.000 m
e = 0.305 m
n = 1 row(s)
Total number of connectors : 20
Lateral restraint of the beam - The beam is laterally restrained at supports
Propping in the construction stage
Number of proppings in the span : 3
Loads
Loads at construction stage
Dead weight of the profile
Permanent loads (g)
0.26 kN/m
2
Dead weight of the slab ( 2.64 kN/m )
2
Qc = 0.75 kN/m
Construction load (Qc)
3.43 kN/m
0.98 kN/m
Loads at final stage
Dead weight of the profile
Permanent loads
0.26 kN/m
2
Dead weight of the slab ( 2.64 kN/m )
3.43 kN/m
Live load case n 1 ( 0 = 0.70)
2
Span
Surface load = 15.00 kN/m
Partial Factors
Permanent loads
Live loads
G.sup = 1.35
Structural steel
M0
= 1.00
G.inf = 1.00
Structural steel (instabilities)
M1
= 1.00
Concrete
= 1.50
Reinforcement bars
= 1.15
Connectors
= 1.25
Shear resistance of the steel sheeting
ap
= 1.10
= 1.50
Software use conditions apply
User's name : B.Gabriel
Date : 13/01/2016
Page 2 / 12
Bejan Gabriel
Project name : Platforma de depozitare
Project reference :
ArcelorMittal Beams Calculator v3.21
Beam reference :
Combinations of actions
ULS combination (construction stage)
1.35 G + 1.50 Qc
ULS combination(s)
1.35 G + 1.50 Q1
SLS combination(s)
G + R + Q1
Software use conditions apply
User's name : B.Gabriel
Date : 13/01/2016
Page 3 / 12
Bejan Gabriel
Project name : Platforma de depozitare
Project reference :
ArcelorMittal Beams Calculator v3.21
Beam reference :
CONSTRUCTION stage
Moment resistance
Section Class 1
Plastic shear force resistance
Vpl.Rd =
MRd =
252.15 kN
78.49 kN.m
( = 1.20)
No risk of shear buckling ( hw / tw < 72 / EN 1993-1-1 6.2.6(6)
ULS combination (construction stage) : 1.35 G + 1.50 Qc
Support reactions
RV 1 =
3.77 kN
RV 2 =
11.17 kN
RV 3 =
7.95 kN
RV 4 =
8.42 kN
RV 5 =
2.95 kN
Critical amplification factor / Lateral Torsional Buckling
cr = 1.90 (LTBeam calc. module)
MEd,max(+) =
1.10 kN.m
VEd,max =
5.89 kN
MEd,max(-) =
-1.59 kN.m
Support reactions
M =
0.020
(x = 1.500 m)
V =
0.023
(x = 1.500 m)
MV =
0.020
(x = 1.500 m)
LT =
0.527
RV 1 =
3.88 kN
RV 2 =
9.97 kN
RV 3 =
6.70 kN
RV 4 =
8.60 kN
RV 5 =
2.92 kN
Critical amplification factor / Lateral Torsional Buckling
cr = 1.34 (LTBeam calc. module)
MEd,max(+) =
1.17 kN.m
VEd,max =
5.78 kN
MEd,max(-) =
-1.43 kN.m
M =
0.018
(x = 1.500 m)
V =
0.023
(x = 1.500 m)
MV =
0.018
(x = 1.500 m)
Software use conditions apply
User's name : B.Gabriel
Date : 13/01/2016
Page 4 / 12
Bejan Gabriel
Project name : Platforma de depozitare
Project reference :
ArcelorMittal Beams Calculator v3.21
Beam reference :
LT =
0.748
Maximum criterion for bending resistance
M.max =
0.020
Maximum criterion for shear force resistance
V.max =
0.023
Maximum criterion for bending moment - shear force interaction
MV.max =
0.020
Maximum criterion for lateral torsional buckling
LT.max =
0.748
Software use conditions apply
User's name : B.Gabriel
Date : 13/01/2016
Page 5 / 12
Bejan Gabriel
Project name : Platforma de depozitare
Project reference :
ArcelorMittal Beams Calculator v3.21
Beam reference :
Serviceability Limit States
(CONSTRUCTION stage)
Deflections per load case
Case 'Dead weight'
Span
Case 'Construction load' (Qc)
Arrangement n 1
Span
Total deflection
Case 'Construction load' (Qc)
vmax =
0.0 mm
vmax =
0.0 mm
vmax =
0.0 mm
vmax =
0.0 mm
vmax =
0.0 mm
Arrangement n 2
Span
Total deflection
Software use conditions apply
User's name : B.Gabriel
Date : 13/01/2016
Page 6 / 12
Bejan Gabriel
Project name : Platforma de depozitare
Project reference :
ArcelorMittal Beams Calculator v3.21
Beam reference :
FINAL stage
Participating width
on left support
1.015 m
L / 4 (= 1.500 m)
1.300 m
3 L / 4 (= 4.500 m)
1.300 m
on right support
1.015 m
...at mid-span
Moments of inertia
Long-term
10942 cm
Short-term
14713 cm
PRd =
Resistance of the connectors
69.41 kN
Verification of the degree of connection
Minimum degree of connection = 0.400
FSteel
917.69 kN
FConcrete
1768.00 kN
Degree of connection = 0.756 > 0.400
The degree of connection is calculated for the section with maximum bending moment
Plastic resistance with partial connection
Plastic shear force resistance
Vpl.Rd =
252.15 kN
( = 1.20)
No risk of shear buckling ( hw / tw < 72 / )
ULS combination : 1.35 G + 1.50 Q1
Support reactions
Calculation of the transverse reinforcement ratio of slab :
RV 1 =
102.69 kN
RV 2 =
102.69 kN
At > 0.70 cm /m
2
At + Ab > 1.84 cm /m
MEd,max(+) =
154.05 kN.m
VEd,max =
102.70 kN
MEd,max(-) =
0.00 kN.m
M =
0.910
(x = 2.200 m)
V =
0.407
(x = 6.000 m)
MV =
0.910
(x = 2.200 m)
Vh =
0.310
Software use conditions apply
User's name : B.Gabriel
Date : 13/01/2016
Page 7 / 12
Bejan Gabriel
Project name : Platforma de depozitare
Project reference :
ArcelorMittal Beams Calculator v3.21
Beam reference :
Longitudinal shear resistance of the slab - Transverse reinforcing bars
Minimum transverse reinforcement ratio :
(EN 1994-1-1 6.6.6.3 & EN 1992-1-1 9.2.2(5))
w,min = 0.09 %
Reinforcement ratio (EN 1992-1-1 6.2.4) :
At > 0.70 cm /m
At + Ab > 1.84 cm /m
Note: this result is provided as an indication.
Calculations must be performed in order to take into account specific conceptual details.
Note particularly that the calculations do not include the design of the slab.
Plastic moment in span
Mpl.Rd =
179.86 kN.m
Maximum criterion for bending resistance
M.max =
0.910
Maximum criterion for shear force resistance
V.max =
0.407
Maximum criterion for bending moment - shear force interaction
MV.max =
0.910
Maximum criterion for longitudinal shear force resistance of slab
Vh.max =
0.310
Software use conditions apply
User's name : B.Gabriel
Date : 13/01/2016
Page 8 / 12
Bejan Gabriel
Project name : Platforma de depozitare
Project reference :
ArcelorMittal Beams Calculator v3.21
Beam reference :
Serviceability Limit States
Deflections per load case
Case 'Dead weight'
vmax =
2.7 mm (L / 2208)
Case 'Other permanent loads'
vmax =
0.0 mm
Case 'Q1'
vmax =
Case 'Shrinkage (R) - Long term'
vmax =
10.7 mm (L / 562)
5.3 mm (L / 1123)
Deflections per combination
vmax =
Combination SLS ' G + R + Q1'
18.7 mm (L / 320)
Estimation of the first natural frequency G + 0.00 Q1 :12.50 Hz
G + 0.10 Q1 :10.11 Hz
G + 0.20 Q1 : 8.72 Hz
G + 0.30 Q1 : 7.77 Hz
G + 0.40 Q1 : 7.08 Hz
G + 0.50 Q1 : 6.55 Hz
G + 0.60 Q1 : 6.12 Hz
G + 0.70 Q1 : 5.77 Hz
G + 0.80 Q1 : 5.47 Hz
G + 0.90 Q1 : 5.21 Hz
G + 1.00 Q1 : 4.99 Hz
Resistance criteria satisfied in the CONSTRUCTION stage
Resistance criteria satisfied in the FINAL stage
Software use conditions apply
User's name : B.Gabriel
Date : 13/01/2016
Page 9 / 12
Bejan Gabriel
Project name : Platforma de depozitare
Project reference :
ArcelorMittal Beams Calculator v3.21
Beam reference :
WARNING !
This software facilitates the preliminary engineering studies with respect to steel constructions. Based on calculation methods complying
with the principles of the applied standards, this software enables to make a certain number of verifications in view of evaluating
a solution for a pre-design. It does not enable to analyse all situations and to make in an exhaustive way all relevant calculations
needed for a study of execution which requires in every case the advice of an external Engineering Office.
Given the complexity of the calculation methods, this software is only intended for professional users active in the sector of steel
constructions (who are fully aware of the possibilities, limits and its adequacy thereof for specific practical cases). The user shall
1use the software under his own responsibility and at his own risks.
This software may be used free of charge. No right is granted to the user of the software, the property and intellectual rights
of which continue to belong exclusively to ArcelorMittal Commercial Sections S.A. (or, depending on the case, to the company of
the ArcelorMittal Group who is owner of these rights). No warranty is granted to the user. ArcelorMittal Commercial Sections S.A.
and/or any other subsidiaries of the ArcelorMittal Group cannot be held liable for any loss or damage directly and/or indirectly
sustained as a result of the use of the software. The user undertakes to hold ArcelorMittal Commercial Sections S.A. free and harmless
from any claim and any direct, indirect and/or consequential damages, in particular those resulting from an incorrect or inappropriate
use or a use made for an inadequate or inappropriate purpose of the software.
All the preliminary design notes done by our company and/or by any other subsidiaries of the ARCELORMITTAL group of our choice
are based on the information received from the Customer. These preliminary design notes are given for guidance only. As such,
they do not commit our company and/or any other subsidiary of the ARCELORMITTAL group to the achievement of a result expected
by the Customer and/or any third person. These preliminary design notes cannot replace all the preliminary design notes which
shall be done by an external engineering office chosen by the Customer. Our company and/or any other subsidiary of the ARCELORMITTAL
group cannot be held liable for any loss or damage, directly or indirectly sustained as a result of the use of the preliminary
design notes done by our company and\or by any other subsidiaries of the ARCELORMITTAL group, whatever the origin of the damage.
Software use conditions apply
User's name : B.Gabriel
Date : 13/01/2016
Page 10 / 12