Technical Data: 65x50 FS2HA 5 7.5

Download as pdf or txt
Download as pdf or txt
You are on page 1of 5

Technical data

Pump name

65x50 FS2HA 5 7.5

10-January -2016

Company

Customer

Date

Contact

Item no.

Issued by

Phone

Project
Project ID

Phone
E-mail

E-mail

Requested data
1

Pump ty pe

End Suction Volute Pump

Fluid

Number of pumps / Reserv e

Liquid temperature

Flow

m/h 0

Head

m 0

Vapour pressure

Static head

m 0

PH v alue

Inlet pressure

Av ailable sy stem NPSH

Env ironmental temperature C 20

Water, clean

Kin. v iscosity

C 20
mm/s 1
bar 0.022
7

Density

bar 0.1
0

kg/m 1000

Solids

Weight % 0
m 1000

Altitude

Pump
Pump name

65x50 FS2HA 5 7.5

10

Design

End Suction Volute Pump

Frequency

11

Manuf acturer

12

Speed

PTEI

13

No. of Stage

14

Connection

Suction side

JIS

10K

15

Connection

Discharge side JIS

10K

16

Max Working Pressure

bar 10

17

Shut-of f head

bar 5.59

18

Total weight

19

Shaf t power

Impeller
Diameter

1/min 2900

Max.

mm 209

Designed

mm 209

Min.

1
Flow

Head

kg See the table of "Dimensions".


kW

20
21

Hz 50

mm 166

Operating

m/h

Max-

m/h 45

Min-

m/h 6

Operating

- (Qmax.)

m 33.5

- (Qmin.)

m 57.1

Max. Shaf t Power at max. impeller kW 6.80


Required NPSH

Ef f iciency

M aterials
22 Casing

Cast iron

M.S.mating ring

Ceramic

23 Impeller

Bronze

M.S.seal ring

Carbon

24 Shaf t

403 Stainless steel

25 Casing ring

Bronze

26 Ball bearing

27 Mechanical seal

M otor
28

Manuf acturer

TECO

Insulation class

29

Ty pe

132S_B3_7.5_3_400

Phases

3~

30

Specif ic design

TEFC / 50 Hz / Pole pairs 1

Frame size

31 Rated power
32

Number of poles

33

Speed

34

Degree of protection

35

Remarks

kW 7.5
2
1/min 2900
IP 55

132 S_7.5
kg

70

Electric v oltage

400

Electric current

13.7

Weight

Performance curve

Pump name

65x50 FS2HA 5 7.5

10-January -2016

Company

Customer

Date

Contact

Item no.

Issued by

Phone

Project
Project ID

Phone
E-mail

E-mail

Pump

Requested data
1

Flow

m/h 0

Operating Flow

m/h

Head

m 0

Operating Head

Static head

m 0

Impeller Diameter

Designed mm 209

Frequency

Hz 50

Speed

Test standard: ISO 9906-Annex A

1/min

Water, clean [100%] ; 20C; 998.3kg/m; 1.005mm/s

Head

[m]

50

Eff.
64.5%
40

209
30

20

10

[%]

0m

NPSH-values
[m] Efficiency
209

60

50

209

40

2
30

20
1

10

0 m/h

0
0

0%
0m
4

12

16

20

24

28

32

36

40

44

48

[m/h]

Dimensions

Pump name

65x50 FS2HA 5 7.5

10-January -2016

Company

Customer

Date

Contact

Item no.

Issued by

Phone

Project
Project ID

Phone
E-mail

E-mail

T otal weight : 146 kg


mm

Pum p dim ensi ons


A
B
BC
BJ
BL
BM
BN1
BN2
BY 1
BY 2
D
DA
Fd

100
360
230
55
820
540
130
150
350
350
180
50
M12

L
MA
MR
n
SA
t

917
215
239
4
65
3

mm

Suction si de
D
e
f
g
h
n Num
t
t1

65
140
175
116
19
4
22
2

mm

Discharge si de
D
e
f
g
h
n Num
t
t1

50
120
155
96
19
4 (Num)
20
2

(1/2)
Construction

Pump name
10-January -2016

65x50 FS2HA 5 7.5


Company

Customer

Date

Contact

Item no.

Issued by

Phone

Project
Project ID

Phone
E-mail

E-mail

(2/2)
Construction

Pump name
10-January -2016

65x50 FS2HA 5 7.5


Company

Customer

Date

Contact

Item no.

Issued by

Phone

Project
Project ID

Phone
E-mail

E-mail

You might also like