5 Calculation Compressed Air System Principal Dimension
5 Calculation Compressed Air System Principal Dimension
5 Calculation Compressed Air System Principal Dimension
Doc. No.
TECHNICAL SPECIFICATION OF COMPRESSED AIR SYSTEM
Rev. No.
Page
5 Calculation Compressed Air System
Principal Dimension
Lpp
=
133.30 m
Lwl
=
134.97 m
B
=
22.50 m
H
=
11.40 m
T
=
8.30 m
Cb
=
0.68
Vs
=
16.0 Knot
=
8.23 m / s
Endurance
=
7 days
=
168 Hours
Main Engine Data
Engine type
Cylinder
SFOC
Cylender Oil Consumption
Power Engine
RPM
Endurance (T)
:
:
:
:
:
:
:
WARTSILA RT-Flex 40
7
175 g/Kwh
0.7 g/Kwh
7945 kW
146 RPM
168 hours
2
53 Nm3/h
Project
Doc. No.
TECHNICAL SPECIFICATION OF COMPRESSED AIR SYSTEM
Rev. No.
Page
Then selected the compressor with the following specifications:
Brand
=
Hatlapa
Type
=
L80II
Capacity
=
57.5 m3/h
Power
=
12 kW
Height
=
775 mm
Length
=
1270 mm
Width
=
655 mm
b. Calculation of Starting Air Receiver
According to Project Guide Wartsila RT-Flex 40, page D-20 :
2
1.7 m3
Based on the above calculation, then the selected air receiver with the following specific
Brand
=
Mellcon
Type
=
AR.05
Capacity
Diameter
Height
=
=
=
2 m3
1100 mm
1700 mm
:
:
:
:
Design IV
13 - 42 12 140 - CA
00
4
:
:
:
:
Design IV
13 - 42 12 140 - CA
00
5
Project
Doc. No.
TECHNICAL SPECIFICATION OF COMPRESSED AIR SYSTEM
Rev. No.
Page
1 Introduction
Compressed Air System is one of system in the ship that used to compressed air. In ge
is compressed by compressor and delivering into air reciever. Compressed air system is
by engine manufacture or product guiede (Wartsila RT-Flex 40) and class regulation (clas
There are three main funtion of compressed air system, such as :
a. Starting Engine
Compressed air is used to start engines. Staring engine devided into tho kinds :
1. Direct Starting
It is called direct starting because compressed air is injected directly into combustion
Direct starting needs high pressure, aproximately about 30 bar according to class.
2. Indirect Starting
Indirect Starting use pneumatic system, electric or pnemuatic motor with pressure a
bar. Indirect starting usually for small engine.
b. Control System (Pneumatic System)
Compress air is also used to valve actuator. Valve actuator drive some equipments, suc
valve for fire fighting, CO2 quick closing valve, LO quick closing valve, emergency stop
engine, manuvering for engine etc. Pressure for control system is about 7-8 bar.
c. General Service
General service like hydropore, blowpipe seachest, horn, cleaning for deck, workshop an
room also use compresses air. It pressure is about 3-4 bar.
1. High Pressure 30
Bar
2. Starting ME and AE
3. 6X start - Non
Reversible
4. 12X start Reversible
1. Medium Pressure
7-8 Bar
2. safety System
a. Remotely
Operated Valve
b. FO / LO Quick
Closing
c. CO2 Valve
3. Control System
ME
a. Maneuvere
b. Emergency
Stop
Project
Doc. No.
TECHNICAL SPECIFICATION OF COMPRESSED AIR SYSTEM
Rev. No.
Page
Project
Doc. No.
TECHNICAL SPECIFICATION OF COMPRESSED AIR SYSTEM
Rev. No.
Page
4 Summary
a. Calculation of Starting Air Compressor
Then selected the compressor with the following specifications:
Brand
=
Hatlapa
Type
=
L80II
Capacity
=
57.5 m3/h
Power
=
12 kW
Height
=
775 mm
Length
=
1270 mm
Width
=
655 mm
=
=
=
2 m3
1100 mm
1700 mm
:
:
:
:
Design IV
13 - 42 12 140 - CA
00
1
to tho kinds :
:
:
:
:
Design IV
13 - 42 12 140 - CA
00
2
:
:
:
:
Design IV
13 - 42 12 140 - CA
00
3