Eltex - FD Sensors

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

ELTEX optical weft stop motion

Weft sensor
The optical weft sensor is of reflecting type. The
weft sensor should be fitted on the front of the
reed. It will not damage the reed. The weft
sensor has a set of optical components enabling
the detection of the weft across the entire air
channel.

The size of the optical weft sensor, the angles of


the optical components and the sensor support
must be made according to the space available on
the weaving machine and to the design of the
reed.

Central control unit 22000


The central control unit is equipped with two channels and
two inputs for weft sensors. The second channel is used for
an ANTI weft sensor. This weft sensor should be placed on
the reed, at a point the weft yarn does not reach, unless the
weft is broken.
The central control unit can detect both a positive and a
negative change of the sensor signal. This means that both
light and dark coloured yarns can be detected.

Functions and specifications


Power supply

24 V DC

Relay stop output

The relay is normally energized. It drops for 1 second when a weft fault
occurs.
Max load on relay contacts: 2 x 1A / 125V AC or
2 x 2A / 30 V DC

Size

Europe size board 100 x 160 mm.


Equipped with a Europe connector DIN 41612 series D, 32 poles

Electronic stop
output

An open collector output is also available. The output is short circuit to


ground during 1 second when a weft fault occurs. Max load is 100 mA.

Yarn arrival
output

One output for each channel is available notifying the arrival time of the yarn.
The pulse is 50 ms long and the positive edge is synchronised with the arrival
time of the yarn.

Input synchronising To use the stop outputs on the central control unit, the unit must be
switch
synchronised with the machine. This can be done with a proximity switch or
with an Eltex light switch. A positive pulse defines the time frame when the
weft yarn arrival is expected. The yarn arrival outputs are available also when
no synchronising switch is used.
Syncronising switch With a connection shunt on the printed circuit board the input can be set
function
to suit a NPN or a PNP type proximity switch. If Eltex light switch is used,
select the NPN position.
Idle pick input

An input to inhibit the stop outputs. This is used when the machine is
weaving without weft (fringing).

ON/OFF switch

When the switch is OFF the stop outputs are inhibited. The machine can
then run without weft.
Other functions of the unit is still active.

ANTI switch

The switch will switch the ANTI weft sensor on or off.

Filter switch

On models where the second channel is used to detect if the weft yarn is
passing too far out, this channel can be set so that it is less sensitive for dust
particles passing the weft sensor. The switch has three positions.

LED indicators

There are five LED indicators:


Stop channel 1
Stop channel 2
Signal from weft sensor channel 1
Signal from weft sensor channel 2
Signal from synchronising switch.

Sensitivity

A potentiometer is available to set the sensitivity in each channel.

Test socket

A five pole test socket is available with the following connections:


Internal power +12 V DC
Ground connection
Signal from synchronising switch
Yarn arrival output channel 1
Yarn arrival output channel 2

Box 24 SE-283 21 OSBY Sweden Tel. +46 479 53 63 00 Fax +46 479 53 63 99
E-mail: [email protected] Web: www.eltex.se
ELTEX U.S. INC.
13031 E. Wade Hampton Blvd
Greer, S C 29651
USA
Tel: 864-879-2131
In U.S. toll free: 1-800-421-1156
Fax: 864-879-3734
Email: [email protected]
2008-05-20/En/B-opto.pmd/TH-0054-03

ELTEX MFG LTD


Railway Road
Templemore, Co. Tipperary
Ireland
Tel: 504-314 33
Fax: 504-310 02
Email: [email protected]

POLSA-ELTEX S.L.
Zamora, 103 - entlo 3
ES-08018 Barcelona
Spain
Tel: 093-309 00 17
Fax: 093-309 59 45
Email: [email protected]

You might also like