Water Curtain Nozzle - HD Fire

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

JUMBO WATER CURTAIN NOZZLE

TECHNICAL DATA
MODEL

JC

- Bronze construction
to IS : 318
JCS - Stainless Steel
construction

SIZE

65 NB, 80 NB, 100 NB

MAXIMUM WORKING 14 Bar (200 PSI)


PRESSURE
FLOW AT 7 Kg./Sq.Cm. 65 NB
80 NB
100 NB
END CONNECTION

1000 LPM
2000 LPM
3000 LPM

Flange to ANSI B16.24


#150 for Bronze
ANSI B16.5 #150 for SS
63 NB instantaneous male
connection for 65 NB size
(optional)

FINISH

Natural finish or Epoxy


painted

ORDERING
INFORMATION

Specify Model Number,


Size, Water curtain type,
Flange connection
specification

least twice in a year or as per the provisions of NFPA


/ TAC or local authority having jurisdiction.
The owner is solely responsible for maintaining the
water spray system and the components therein so
that it performs properly when required.

DESCRIPTION
Jumbo Water Curtain Nozzle produces a flat curtain
of water projecting upward. These nozzles are used to
segregate the area by creating a water curtain.
The nozzle is made out of bronze as well as stainless
steel construction. A nozzle up to 1000 LPM flow
can be provided with instantaneous male connection
for connecting the fire hoses for portable application.
The area coverage graph provided is in standstill
air condition, hence the wind velocity at the site of
installation is to be considered while designing the
system for area coverage.
It is recommended to install main pipeline stainer in
the system.

MAINTENANCE
The Jumbo curtain nozzle must be handled with due
care. For best results, the storage as well as any
further shipment be made in original packing only.
Nozzle which is visibly damaged should not be installed.
It is recommended that water spray system be
inspected regularly by authorised technical personnel.
The nozzle must be checked for atmospheric effects,
external and internal obstruction, blockage if any. The
nozzle should be cleaned or replaced if required. The
system must be operated with optimum water flow at
OCTOBER, 2013

PAGE 1 OF 2

HD 114

WATER CURTAIN TYPE - B

WATER CURTAIN TYPE - A

A
A

APPROXIMATE WATER CURTAIN COVERAGE


SIZE

FLOW IN LPM
AT 7 KG/SQ.CM.

A
MTS

B
MTS

65 NB

1000

18

6.5

80 NB

2000

27

100 NB

3000

33

11

APPROXIMATE WATER CURTAIN COVERAGE


SIZE

FLOW IN LPM
AT 7 KG/SQ.CM.

A
MTS

B
MTS

65 NB

1000

16

80 NB

2000

25

12

100 NB

3000

30

14

DIMENSION in millimeter (Approximate)

SIZE
C

65 NB

250

450

205

80 NB

250

450

205

100 NB

250

500

220

Note: The spray data is obtained from the testing carried out in still air.

LIMITED WARRANTY
HD FIRE PROTECT PVT. LTD. hereby referred to as HD FIRE warrants to the original purchaser of the fire protection products manufactured by HD FIRE and to any other person
to whom such equipment is transferred, that such products will be free from defect in material and workmanship under normal use and care, for two (2) years from the date of
shipment by HD FIRE. Products or Components supplied or used by HD FIRE, but manufactured by others, are warranted only to the extent of the manufacturers warranty.
No warranty is given for product or components which have been subject to misuse, improper installation, corrosion, unauthorized repair, alteration or un-maintained.
HD FIRE shall not be responsible for system design errors or improper installation or inaccurate or incomplete information supplied by buyer or buyers representatives.
HD FIRE will repair or replace defective material free of charge, which is returned to our factory, transportation charge prepaid, provided after our inspection the material is
found to have been defective at the time of initial shipment from our works. HD FIRE shall not be liable for any incidental or consequential loss, damage or expense arising directly
or indirectly from the use of the product including damages for injury to person, damages to property and penalties resulting from any products and components manufactured
by HD FIRE. HD FIRE shall not be liable for any damages or labour charges or expense in making repair or adjustment to the product. HD FIRE shall not be liable for any
damages or charges sustained in the adaptation or use of its engineering data & services. In no event shall HD Fires product liability exceed an amount equal to the sale price.
The foregoing warranty is exclusive and in lieu of all other warranties and representation whether expressed, implied, oral or written, including but not limited
to, any implied warranties or merchantability or fitness for a particular purpose. All such other warranties and representations are hereby cancelled.
NOTICE :
The equipment presented in this bulletin is to be installed in accordance with the latest publication standards of NFPA or other similar organisations and also with
the provision of government codes or ordinances wherever applicable.
The information provided by us are to the best of our knowledge and belief, and are general guidelines only. Site handling and installation control is beyond our reach.
Hence we give no guarantee for result and take no liability for damages, loss or penalties whatsoever, resulting from our suggestion, information, recommendation or
damages due to our product.
Product development is a continuous programme of HD FIRE PROTECT PVT. LTD. and hence the right to modify any specification without prior notice is reserved with
the company.

HD FIRE PROTECT PVT. LTD.


Protecting What Matters Most to You

OCTOBER, 2013

C-3/6, THE NANDANVAN IND. ESTATE, L.B.S. MARG, THANE 400 604., INDIA.
PHONES : + (91) 22 2583 5434 2582 6958 2582 6793
FAX : +(91) 22 2581 2524 6796 9049
EMAIL : [email protected] WEBSITE : www.hdfire.com

PAGE 2 OF 2

HD 114

You might also like