GC310

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

Automatic Mains Failure microprocessor based genset controller for the most

common three-phases generator applications (Single Prime Mover and Single


Stand-by gensets)

J1939 and MTU MDEC CAN interface

Interface with traditional sensors engines

True RMS readings on generator and mains voltages and currents

Active, Reactive and apparent power measurement

Frequency and power measurement on Mains input

Engine speed measurement by pick-up or W

8+3 fully programmable digital input

Up to 8 digital output (6 programmable)

Additional current measurement for neutral or differential protection (51N)

RS232 interface port with MODBUS RTU protocol

Graphic display

Real Time Clock

Events and data logging

Remote control systems

Automatic Mains Failure microprocessor based genset


controller for the most common three-phases generator
applications (Single Prime Mover and Single Stand-by
gensets)
GC310 is designed for electronic engines with CAN interface
J1939 protocol and even for traditional engines with
sensors.
The adjustable parameters of the controller allow the use of this
controller for standard and customized tasks. Parameters are
programmed using the free software tool (BoardPrg), which can
be download thorough Sices web site. Its even possible to set
them directly by the keyboard of GC310.
The graphic display is an user-friendly human interface which is
useful for an immediate visualization of measures and alarms
coming form the genset.
GC310 is able to measure the Mains frequency and compute
the power and energy even when the load is connected to the
Mains.
Events and DTC logs can be accessed from the front panel
and read on the display.
GC310 is supported by several communications devices/tools
for local or remote control, using SicesSupervisor or an own
supervision system.

Generator Voltages:
L1-L2, L2-L3, L3-L1
True RMS measure.
Lx-N max. voltage < 300Vac cat. IV
High voltage pulse = 6kV 1.2/50 us
Max. measurable voltage = 25.000V (by external TV).
Generator Currents:
L1, L2, L3, N (*)
True RMS measure.
Nominal max. current: 5Aac
Overload measurable current : 4 x 5Aac (sinusoidal).
Internal current transformer.
Max. nominal current = 6000A (by external TA).
(*) Neutral generator current as alternative to differential
protection or to be used for measure mains power.
Mains Voltage:
L1-L2, L2-L3, L3-L1
Average measure calibrated to RMS.
Lx-N max. voltage < 300Vac cat. IV
High voltage pulse = 6kV 1.2/50 us
Max. measurable voltage = 25.000V (by external TV).
Generator and Mains Frequency meter:
Resolution = 0.1 Hz.
Accuracy = 50ppm, 35ppm/C (typical)
Battery Voltmeter:
Resolution = 0.1V
Oil Pressure Gauge:
VDO 0-10 Bar, VDO 0-5 Bar, Veglia 0-8 Bar
(optional 0-10V input)
Water Thermometer:
VDO
(optional 0-10V input)
Fuel Level:
VDO, Veglia

Engine revolution counter:


By pick-up. Programmable teeth number.
Same input can be used by W signal.
Power and power factor measures are available as total
measure and also for each single phase.
Maximum power and current reached values, are
memorized with date and time.
Additional measures available based on CAN J1939 list.

A set of high efficiency led are used for signaling the


current status of the Generator Set and for the
visualization of alarm accursed. Secondary alarms are
represented by their corresponding display code.
Status
Mains live
Generator live
Mains contactor closed
Generator contactor closed
Engine running
Engine Cooling
Engine start and stop
Engine protections
Fuel reserve
Max./Min fuel level
Fuel finished
Battery failure (min./max. Voltage)
Max./Min. oil pressure
Max./Min engine temperature
Closing of mains contactor or gen set contactor failed
Engine over crank
Over speed (electronic from generator frequency or from
pick-up)
Generator overload (from external contact of circuit breaker)
Fuel end
Belt breakage
Operating conditions not reached
Emergency Stop
Generator protections
Underfrequency (81U)
Overfrequency (81O)
Undervoltage (27)
Overvoltage (59)
Power direction (32)
Time dependent overcurrent (51)
Instantaneous overcurrent (50)
Phase sequence
Current (46) and Voltage (60) unbalance
Phase overcurrent with voltage restraint/control (51V)
Differential protection (51N) as option

Mains protections
Mains voltage Max./Min.
Mains frequency Max./Min.
Mains failure

8
3
2
4
2

Programmable digital and insulated inputs


Analogue inputs, if not used, can be used as not insulated
digital inputs
Relay (3A) fuel solenoid + Crank
Digital programmable and insulated digital outputs
SPDT (10A) relays for power changeover management

As option:
16
10
10
4

Additional and configurable digital I/O with DITEL module


Additional and configurable analogical Input for sensors
measure
from
Pt100
(DIGRIN),
Thermocouples
(DITHERM) or 0...10mA - 0...20mA (DIVIT)
Additional and fixed analogical input listed in CANBUS
J1939 protocol
Additional and configurable analogical output (DANOUT)

Engine diagnostic code


Periodical test.
Real Time Clock
Fuel pump management.
Pre-glow and coolant heater management
Remote start and stop
Maintenance working
Embedded alarm horn
Engine speed measurement by pick-up or W

Serial port RS232 Modbus RTU


CAN interface for ECU interface (J1939 and MTU MDEC)
GSM and PSTN modem management
Automatic call in case of alarm

As option:

Converter insulated RS232/485 Modbus RTU


Remote communication via SMS with additional GSM/
GPRS/GPS modem

Ethernet connection by means additional electronic module


Gateway Modbus TCP/IP RTU

Supervision software for remote control available


GC310 is a MULTILANGUAGE DEVICE. The display languages
available are: English, Italian, French, Russian and Portuguese/
Brazilian

Supply voltage: 732 Vdc


Power consumption: typical less than 2W (AUTO mode, STANDBY, AMF active, LCD Lamp Saving active).
Operating frequency 50Hz or 60Hz
LCD: transflective with LED backlight.
Operating temperature: -25 C to 70 C
Protection degree: IP55
Weight: 830g
Overall dimension: 247x187mm (LxH)
Panel cutout: 218x159 (LxH)
Graphic display dimensions: 70 x 38mm - 128 x 64 pixel
Specific function for French market EJP / EJP-T
EMC: conform to EN61326-1
Safety: built in conformity to EN61010-1
If required, available tropicalized version for hazardous areas.

You might also like