Manual YSCC18FSAADG PDF
Manual YSCC18FSAADG PDF
YSCC18FSAADG
This service information is designed for experienced repair technicians only and is not designed for use by the general public.
It does not contain warnings or cautions to advise non-technical individuals of potential dangers in attempting to service a product.
Products powered by electricity should be serviced or repaired only by experienced professional technicians. Any attempt to service or
repair the product or products dealt with in this service information by anyone else could result in serious injury or death
YSCC18FSAADG
Table of Contents
1. Features..................................................................................................... 1
2. Introduction ............................................................................................... 2
3. Specifications ............................................................................................ 7
4. Printed circuit board connector wiring diagram .................................... 9
5. Functions and control ............................................................................. 10
5.1 Main functions and control specification .................................................. 10
5.2 Value of thermistor ................................................................................... 13
6. System configuration ............................................................................... 21
6.1 System configuration ................................................................................ 21
6.2 Instruction ................................................................................................. 22
7. Service diagnosis .................................................................................... 29
7.1 Problem symptoms and measures .......................................................... 29
7.2 Error codes and description indoor display .............................................. 29
8. Capacity diagrams and curves diagrams ............................................... 32
9. Installations ............................................................................................... 34
10.Wiring Diagrams ....................................................................................... 38
11. Description of coding rules of unit model ............................................. 45
YSCC18FSAADG
Table of Contents
YSCC18FSAADG
Table of Contents
2. Introduction
2.1 Safety Cautions
Be sure to read the following safety cautions before conducting repair work.
The caution items are classified into Warning and Caution. The Warning items are especially important
since they can lead to death or serious injury if they are not followed closely. The Caution items can also lead
to serious accidents under some conditions if they are not followed. Therefore, be sure to observe all the safety
caution items described below.
About the pictograms
This symbol indicates an item for which caution must be exercised.
The pictogram shows the item to which attention must be paid.
This symbol indicates a prohibited action.
The prohibited item or action is shown inside or near the symbol.
This symbol indicates an action that must be taken, or an instruction.
The instruction is shown inside or near the symbol.
After the repair work is complete, be sure to conduct a test operation to ensure that the equipment operates
normally, and explain the cautions for operating the product to the customer.
YSCC18FSAADG
Introduction
Warning
Do not repair the electrical components with wet hands. Working on the equipment with wet hands can
cause an electrical shock.
Do not clean the air conditioner by splashing water. Washing the unit with water can cause an electrical
shock.
Be sure to provide the grounding when repairing the equipment in a humid or wet place, to avoid electrical
shocks.
Be sure to turn off the power switch and unplug the power cable when cleaning the equipment. The
internal fan rotates at a high speed, and cause injury.
Do not tilt the unit when removing it. The water inside the unit can spill and wet the furniture and floor.
Be sure to check that the refrigerating cycle section has cooled down sufficiently before conducting repair
work. Working on the unit when the refrigerating cycle section is hot can cause burns.
Use the welder in a well-ventilated place. Using the welder in an enclosed room can cause oxygen
deficiency.
For
Incorrect use of the installation frame and improper installation can cause the equipment to fall, resulting
in injury.
integral
units only
Be sure to install the product securely in the installation frame mounted on a window frame.
If the unit is not securely mounted, it can fall and cause injury.
For
integral
units only
Introduction
YSCC18FSAADG
Warning
Be sure to use an exclusive power circuit for the equipment, and follow the technical standards related to
the electrical equipment, the internal wiring regulations and the instruction manual for installation when
conducting electrical work.
Insufficient power circuit capacity and improper electrical work can cause an electrical shock or fire.
Be sure to use the specified cable to connect between the indoor and outdoor units. Make the
connections securely and route the cable properly so that there is no force pulling the cable at the
connection terminals.
Improper connections can cause excessive heat generation or fire.
When connecting the cable between the indoor and outdoor units, make sure that the terminal cover does
not lift off or dismount because of the cable.
If the cover is not mounted properly, the terminal connection section can cause an electrical shock,
excessive heat generation or fire.
Do not damage or modify the power cable.
Damaged or modified power cable can cause an electrical shock or fire. Placing heavy items on the
power cable, and heating or pulling the power cable can damage the cable.
Do not mix air or gas other than the specified refrigerant (R-410A / R22) in the refrigerant system.
If air enters the refrigerating system, an excessively high pressure results, causing equipment damage
and injury.
If the refrigerant gas leaks, be sure to locate the leak and repair it before charging the refrigerant. After
charging refrigerant, make sure that there is no refrigerant leak.
If the leak cannot be located and the repair work must be stopped, be sure to perform pump-down and
close the service valve, to prevent the refrigerant gas from leaking into the room. The refrigerant gas itself
is harmless, but it can generate toxic gases when it contacts flames, such as fan and other heaters,
stoves and ranges.
When replacing the coin battery in the remote controller, be sure to disposed of the old battery to prevent
children from swallowing it.
If a child swallows the coin battery, see a doctor immediately.
Caution
Installation of a leakage breaker is necessary in some cases depending on the conditions of the
installation site, to prevent electrical shocks.
Do not install the equipment in a place where there is a possibility of combustible gas leaks.
If a combustible gas leaks and remains around the unit, it can cause a fire.
Be sure to install the packing and seal on the installation frame properly. If the packing and seal are not
installed properly, water can enter the room and wet the furniture and floor.
For
integral
units only
Introduction
YSCC18FSAADG
Warning
Do not use a joined power cable or extension cable, or share the same power outlet with other electrical
appliances, since it can cause an electrical shock, excessive heat generation or fire.
Caution
Check to see if the parts and wires are mounted and connected properly, and if the connections at the
soldered or crimped terminals are secure. Improper installation and connections can cause excessive
heat generation, fire or an electrical shock.
If the installation platform or frame has corroded, replace it. Corroded installation platform or frame can
cause the unit to fall, resulting in injury.
Check the grounding, and repair it if the equipment is not properly grounded. Improper grounding can
cause an electrical shock.
Be sure to measure the insulation resistance after the repair, and make sure that the resistance is 1 M
ohm or higher.
Faulty insulation can cause an electrical shock.
Be sure to check the drainage of the indoor unit after the repair.
Faulty drainage can cause the water to enter the room and wet the furniture and floor.
Introduction
YSCC18FSAADG
Type of Information
Description
A note provides information that is not indispensable, but may
Note:
Note
Caution
Caution
Warning
Warning
Specifications
YSCC18FSAADG
HSU18VCK
Model
Cooling
5.27/5.12
KW
Capacity Rated
Btu/h
18000/17500
kcl/h
4532/4408
POWER SUPP LY
NOMINAL
DISTRIBUTION
SYSTEM
VO LTAGE
VM
Phase
Frequency
Voltage
1PH
60
HZ
230/208V
Moisture Removal
L/h
4.0
Running Current(Rated)
7.2/7.6
1600/1550
EER Rated
3.3
W/W
Piping Connections
(external diameter)
Liquid
mm
6.35
Gas
mm
9.52
Drain
mm
16
Heat Insulation
Max.Piping Length
10
Max.Level Di fference
Chargeless
g/m
20
m/ min(cfm)
14.5(511.9)
13.3(469.2)
12.08(426.5)
Type
Fan
Motor Output
Speed
Steps
Right,Left,Horizontal,Downward
Air Filter
Run current(rated)
0.1
Power consumption
25
Microcomputer Control
Temperature Control
Dimensions(WxDxH)
mm
1046X299X234
Packaged Dimensions(WxDxH)
mm
1126X388X344
Weight
kg
Gross Weight
kg
Operation Sound
Sound Power
H/M/L
H(cooling/heating)
13
16.5
49/46.5/43.5
dBA
dBA
59
Specifications
YSCC18FSAADG
Outdoor Unit
HSU18VCK
Casing Color
lvory white
Type
Model
Compressor
Motor Output
Oil Type
Oil Charge
1805
0.56
Model
Refrigerant
Charge
R410A
1.3
kg
50
m/min
cfm
1765
Axial fan
Type
Fan
27
Runing current(rated)
7.2/7.6
Power Consumption(rated)
1600/1550
Motor Output
Dimensions(WxDxH)(stop valve,
and bottom support is not included)
mm
Packaged Dimensions(WxDxH)
mm
Weight
Gross Weight
Operation Sound
Sound Power
H
H(cooling/heating)
860X308X730
995X420X815
kg
46.5
kg
50.5
dBA
60
dBA
70
YSCC18FSAADG
CH1
CN54
CN26
CN11
CN32
CN48
CN1
CON38
DomesticAirConditioner
YSCC18FSAADG
10
DomesticAirConditioner
YSCC18FSAADG
(1)High temperature expiration prevention:When the temp.of coil pipe is above 161F,compressor
and outlet air stop running 10 seconds later, and inlet air runs as the temp. sensor is off. When compressor stands by for 3 minute and the temp. of coil pipe is below 149F, the unit can be started again.
Protection of frost is available (disable in test run or heating mode): In order to prevent the indoor
heat exchanger from freezing (in refrigation or dehumidifying mode), the compressor will be shut off
when the temperature of the indoor coil pipe is or below 30F and the compressor runs for over 5 minutes.when the temperature of the indoor coil pipe ascends to over 44F, the compressor is restarted
(must meet a 3-minutes delay)
Timer on, Timer off and sleep control are available.
5.1.4 Dehumidifying mode
You can set 24-hour timer on or timer off as required, and the minum time unit is 1 minute. After
setting, the indicator of indoor unit is on , and it is off when timer setting is completed. There are several
timer mode as follows.
5.1.5.1 Timer on: The LED of timer on lights up, and unit behaves with halt status. Timer on is
completed, and then unit starts running with the LED of timer on off. The unit starts with the the last
setting receiving timer signals, and sleep setting is not allowed.
5.1.5.2 Timer off: Unit starts, timer indicator lights up; When reaching time setting, the indicator
goes out, unit enters shut down mode, and sleep function can be set. If timer off and sleep are set
synchronously, the one which time is short run first. Executing shutdown instruction clear timer and sleep
function.
5.1.5.3 Timer on and timer off can be set synchronously.
5.1.6 Sleep function: the timer indicator lights up.
5.1.6.1 In cooling/defrosting mode, the temp. setting increases 1 F one hour later after start up.
After another hour the temp. setting increase by more 1 F and then run continuously for another 6
11
DomesticAirConditioner
YSCC18FSAADG
5.1.6.2 In heating mode, the temp. setting decrease 3 F one hour after start up. After another hour the
temp. setting decrease by more 3 F. After 3 hours the temp. setting rise by 1 F and then run
continuously for another 3 hours and then close
5.1.6.3 If the wind speed is set to high before going to bed, the wind speed become medium after
start up; If the wind speed is set to medium before going to bed, the wind speed become low after start
up; If the wind speed is set to low before going to bed, the wind speed keep unchanged.
5.1.7
5.1.7.1 Press the switch of emergency operation, then buzzer rings once and unit enters the
automatic operation mode. (emergency operation)
5.1.7.2 If the switch is kept pressed for 5 seconds, buzzer ring two times and unit enter enter test
run mode.
5.1.7.3 Press the switch again, and then closes.
5.1.7.4 Enter emergency operation from timer mode, then timer is cancelled.
5.1.8 Test run:
5.1.8.1 The temperature sensor of inlet air doesnt work, and compressor starts (but subject to the
limit of -minute delay excluding the first time), and high wind, cooling, and air door is open.The indoor fan
motor runs, running indicator lights up, compressor relay and the one of outdoor fan motor is closed
5.1.8.2 During test run:
The prevention of freezing of evaporator doesnt work.
Current cross control doesnt work.
The control of current cross peak expiration doesnt work.
Temperature control doesnt work.
Temperature expiration control doesnt work.
5.1.9 memory function The memory function of power down is available, and the auto recovery
12
DomesticAirConditioner
YSCC18FSAADG
function of power on is optional. (In auto, heating, cooling, or defrosting status, press the
to enter additional options when cycle dispay to
press
button
quickly
of power on can be set on/off. If the buzzer rings 4 times, the the auto recovery function of power on is
available; If the buzzer rings 2 times, the the auto recovery function of power on is unavailable.)
If there is no EEPROM, the unit is taken off the off function of the memory function of power down. But
the memory function of power down can also be set on/off, and the data is the default value of chip
/50 =4200K3%
Max.(K)
Normal(K
0LQ.
-30
568.8372
501.0746
440.8435
-1.97
1.75
-29
530.9600
468.6491
413.1441
-1.95
1.74
-28
495.8488
438.5314
387.3645
-1.93
1.72
-27
463.2850
410.5433
363.3602
-1.91
1.71
-26
433.0683
384.5212
340.9980
-1.90
1.70
-25
405.0156
360.3153
320.1558
-1.88
1.69
-24
378.9588
337.7879
300.7211
-1.86
1.67
-23
354.7440
316.8126
282.5905
-1.84
1.66
-22
332.2300
297.2732
265.6686
-1.82
1.64
-21
311.2873
279.0627
249.8676
-1.80
1.63
-20
291.7969
262.0831
235.1067
-1.78
1.62
-19
273.6494
246.2437
221.3111
-1.76
1.60
-18
256.7445
231.4612
208.4122
-1.74
1.59
-17
240.9897
217.6590
196.3462
-1.72
1.57
-16
226.3000
204.7662
185.0545
-1.70
1.56
-15
212.5973
192.7176
174.4829
-1.68
1.54
-14
199.8093
181.4531
164.5813
-1.66
1.53
-13
187.8698
170.9169
155.3033
-1.64
1.51
-12
176.7176
161.0578
146.6059
-1.62
1.49
-11
166.2961
151.8284
138.4495
-1.60
1.48
-10
156.5532
143.1847
130.7973
-1.58
1.46
-9
147.4409
135.0863
123.6153
-1.56
1.44
-8
138.9148
127.4956
116.8717
-1.53
1.43
-7
130.9337
120.3778
110.5374
-1.51
1.41
-6
123.4597
113.7009
104.5852
-1.49
1.39
-5
116.4577
107.4349
98.9897
-1.47
1.38
Temp.(
13
Tolerance(
DomesticAirConditioner
YSCC18FSAADG
-4
109.8953
101.5523
93.7278
-1.45
1.36
-3
103.7422
96.0274
88.7774
-1.43
1.34
-2
97.9708
90.8365
84.1185
-1.40
1.32
-1
92.5551
85.9574
79.7322
-1.38
1.30
87.4712
81.3697
75.6011
-1.36
1.29
82.6970
77.0544
71.7088
-1.34
1.27
78.2118
72.9937
68.0402
-1.31
1.25
73.9966
69.1712
64.5813
-1.29
1.23
70.0335
65.5716
61.3188
-1.27
1.21
66.3062
62.1807
58.2405
-1.24
1.19
62.7992
58.9853
55.3351
-1.22
1.17
59.4984
55.9729
52.5917
-1.20
1.15
56.3905
53.1320
50.0006
-1.17
1.13
53.4631
50.4521
47.5523
-1.15
1.11
10
50.7048
47.9230
45.2384
-1.13
1.09
11
48.1049
45.5355
43.0505
-1.10
1.07
12
45.6534
43.2808
40.9813
-1.08
1.04
13
43.3410
41.1509
39.0236
-1.05
1.02
14
41.1592
39.1381
37.1708
-1.03
1.00
15
39.0998
37.2355
35.4167
-1.00
0.98
16
37.1553
35.4363
33.7555
-0.98
0.96
17
35.3186
33.7344
32.1818
-0.95
0.94
18
33.5833
32.1240
30.6905
-0.93
0.91
19
31.9432
30.5997
29.2769
-0.90
0.89
20
30.3925
29.1565
27.9365
-0.88
0.87
21
28.9259
27.7895
26.6651
-0.85
0.84
22
27.5383
26.4944
25.4589
-0.83
0.82
23
26.2252
25.2670
24.3140
-0.80
0.80
24
24.9822
24.1034
23.2271
-0.78
0.77
25
23.8050
23.0000
22.1950
-0.78
0.77
26
22.7500
21.9499
21.1520
-0.78
0.78
27
21.7477
20.9536
20.1638
-0.82
0.81
28
20.7951
20.0081
19.2272
-0.86
0.85
29
19.8895
19.1104
18.3394
-0.89
0.88
30
19.0285
18.2581
17.4974
-0.93
0.92
31
18.2094
17.4484
16.6988
-0.97
0.95
32
17.4302
16.6792
15.9410
-1.00
0.99
33
16.6885
15.9480
15.2217
-1.04
1.02
34
15.9825
15.2530
14.5389
-1.08
1.06
35
15.3103
14.5920
13.8903
-1.12
1.09
36
14.6700
13.9632
13.2743
-1.16
1.13
37
14.0599
13.3650
12.6889
-1.20
1.16
38
13.4786
12.7957
12.1325
-1.23
1.20
14
DomesticAirConditioner
YSCC18FSAADG
39
12.9244
12.2537
11.6035
-1.27
1.24
40
12.3960
11.7375
11.1004
-1.31
1.27
41
11.8921
11.2459
10.6218
-1.35
1.31
42
11.4113
10.7775
10.1665
-1.39
1.34
43
10.9526
10.3311
9.7330
-1.43
1.38
44
10.5147
9.9056
9.3204
-1.48
1.42
45
10.0967
9.4999
8.9275
-1.52
1.45
46
9.6976
9.1130
8.5532
-1.56
1.49
47
9.3163
8.7439
8.1965
-1.60
1.53
48
8.9521
8.3916
7.8566
-1.64
1.57
49
8.6040
8.0554
7.5327
-1.68
1.60
50
8.2713
7.7345
7.2237
-1.73
1.64
51
7.9531
7.4280
6.9291
-1.77
1.68
52
7.6489
7.1353
6.6480
-1.81
1.72
53
7.3580
6.8556
6.3797
-1.85
1.76
54
7.0796
6.5884
6.1237
-1.90
1.79
55
6.8131
6.3329
5.8793
-1.94
1.83
56
6.5581
6.0887
5.6459
-1.99
1.87
57
6.3140
5.8552
5.4230
-2.03
1.91
58
6.0802
5.6318
5.2100
-2.07
1.95
59
5.8563
5.4181
5.0065
-2.12
1.99
60
5.6417
5.2136
4.8120
-2.16
2.03
61
5.4361
5.0178
4.6260
-2.21
2.07
62
5.2391
4.8304
4.4481
-2.25
2.11
63
5.0502
4.6510
4.2780
-2.30
2.15
64
4.8691
4.4791
4.1153
-2.35
2.19
65
4.6954
4.3145
3.9596
-2.39
2.23
66
4.5287
4.1567
3.8105
-2.44
2.27
67
4.3689
4.0055
3.6678
-2.49
2.31
68
4.2154
3.8605
3.5312
-2.53
2.35
69
4.0682
3.7216
3.4004
-2.58
2.39
70
3.9268
3.5883
3.2750
-2.63
2.43
71
3.7910
3.4605
3.1549
-2.68
2.48
72
3.6606
3.3378
3.0398
-2.73
2.52
73
3.5353
3.2201
2.9294
-2.77
2.56
74
3.4150
3.1072
2.8237
-2.82
2.60
75
3.2993
2.9987
2.7222
-2.87
2.64
76
3.1881
2.8946
2.6249
-2.92
2.68
77
3.0812
2.7946
2.5316
-2.97
2.73
78
2.9785
2.6986
2.4420
-3.02
2.77
79
2.8796
2.6063
2.3560
-3.07
2.81
80
2.7845
2.5176
2.2735
-3.12
2.86
81
2.6931
2.4324
2.1943
-3.17
2.90
15
DomesticAirConditioner
YSCC18FSAADG
82
2.6050
2.3505
2.1182
-3.22
2.94
83
2.5203
2.2717
2.0451
-3.28
2.99
84
2.4388
2.1960
1.9749
-3.33
3.03
85
2.3602
2.1231
1.9075
-3.38
3.07
86
2.2846
2.0530
1.8426
-3.43
3.12
87
2.2118
1.9856
1.7803
-3.48
3.16
88
2.1416
1.9207
1.7204
-3.54
3.20
89
2.0740
1.8582
1.6628
-3.59
3.25
90
2.0089
1.7981
1.6074
-3.64
3.29
91
1.9461
1.7402
1.5541
-3.70
3.34
92
1.8856
1.6844
1.5028
-3.75
3.38
93
1.8272
1.6307
1.4535
-3.80
3.43
94
1.7709
1.5789
1.4060
-3.86
3.47
95
1.7166
1.5291
1.3603
-3.91
3.52
96
1.6643
1.4810
1.3163
-3.97
3.56
97
1.6138
1.4347
1.2739
-4.02
3.61
98
1.5650
1.3900
1.2331
-4.08
3.66
99
1.5180
1.3470
1.1937
-4.13
3.70
100
1.4726
1.3054
1.1559
-4.19
3.75
101
1.4287
1.2654
1.1194
-4.24
3.80
102
1.3864
1.2268
1.0842
-4.30
3.84
103
1.3455
1.1895
1.0503
-4.36
3.89
104
1.3060
1.1535
1.0176
-4.42
3.94
105
1.2679
1.1188
0.9860
-4.47
3.98
106
1.2310
1.0853
0.9556
-4.53
4.03
107
1.1954
1.0529
0.9263
-4.59
4.08
108
1.1610
1.0217
0.8980
-4.65
4.13
109
1.1277
0.9915
0.8707
-4.70
4.17
110
1.0955
0.9624
0.8443
-4.76
4.22
111
1.0644
0.9342
0.8189
-4.82
4.27
112
1.0344
0.9070
0.7943
-4.88
4.32
113
1.0053
0.8807
0.7706
-4.94
4.37
114
0.9771
0.8553
0.7478
-5.00
4.41
115
0.9499
0.8307
0.7256
-5.06
4.46
116
0.9235
0.8070
0.7043
-5.12
4.51
117
0.8980
0.7840
0.6837
-5.18
4.56
118
0.8734
0.7618
0.6637
-5.24
4.61
119
0.8495
0.7404
0.6445
-5.30
4.66
120
0.8263
0.7196
0.6258
-5.36
4.71
16
DomesticAirConditioner
YSCC18FSAADG
Pipe Sensor
R25 =10K3%
B25
/50 =3700K3%
Max.(K)
Normal(K
0LQ.
-30
165.2170
147.9497
132.3678
-1.94
1.75
-29
155.5754
139.5600
125.0806
-1.93
1.74
-28
146.5609
131.7022
118.2434
-1.91
1.73
-27
138.1285
124.3392
111.8256
-1.89
1.71
-26
130.2371
117.4366
105.7989
-1.87
1.70
-25
122.8484
110.9627
100.1367
-1.85
1.69
-24
115.9272
104.8882
94.8149
-1.83
1.67
-23
109.4410
99.1858
89.8106
-1.81
1.66
-22
103.3598
93.8305
85.1031
-1.80
1.64
-21
97.6556
88.7989
80.6728
-1.78
1.63
-20
92.3028
84.0695
76.5017
-1.76
1.62
-19
87.2775
79.6222
72.5729
-1.74
1.60
-18
82.5577
75.4384
68.8710
-1.72
1.59
-17
78.1230
71.5010
65.3815
-1.70
1.57
-16
73.9543
67.7939
62.0907
-1.68
1.55
-15
70.0342
64.3023
58.9863
-1.66
1.54
-14
66.3463
61.0123
56.0565
-1.64
1.52
-13
62.8755
57.9110
53.2905
-1.62
1.51
-12
59.6076
54.9866
50.6781
-1.60
1.49
-11
56.5296
52.2278
48.2099
-1.58
1.47
-10
53.6294
49.6244
45.8771
-1.56
1.46
-9
50.8956
47.1666
43.6714
-1.54
1.44
-8
48.3178
44.8454
41.5851
-1.51
1.42
-7
45.8860
42.6525
39.6112
-1.49
1.40
-6
43.5912
40.5800
37.7429
-1.47
1.39
-5
41.4249
38.6207
35.9739
-1.45
1.37
-4
39.3792
36.7676
34.2983
-1.43
1.35
-3
37.4465
35.0144
32.7108
-1.41
1.33
-2
35.6202
33.3552
31.2062
-1.38
1.31
-1
33.8936
31.7844
29.7796
-1.36
1.29
32.2608
30.2968
28.4267
-1.34
1.28
30.7162
28.8875
27.1431
-1.32
1.26
29.2545
27.5519
25.9250
-1.29
1.24
27.8708
26.2858
24.7686
-1.27
1.22
26.5605
25.0851
23.6704
-1.25
1.20
25.3193
23.9462
22.6273
-1.23
1.18
24.1432
22.8656
21.6361
-1.20
1.16
23.0284
21.8398
20.6939
-1.18
1.14
Temp.((
))
17
Tolerance(
DomesticAirConditioner
YSCC18FSAADG
21.9714
20.8659
19.7982
-1.15
1.12
20.9688
19.9409
18.9463
-1.13
1.09
10
20.0176
19.0621
18.1358
-1.11
1.07
11
19.1149
18.2270
17.3646
-1.08
1.05
12
18.2580
17.4331
16.6305
-1.06
1.03
13
17.4442
16.6782
15.9315
-1.03
1.01
14
16.6711
15.9601
15.2657
-1.01
0.99
15
15.9366
15.2770
14.6315
-0.98
0.96
16
17
15.2385
14.5748
14.6268
14.0271
14.0079
13.4510
-0.96
-0.93
0.94
0.92
18
13.9436
13.4185
12.9017
-0.91
0.90
19
13.3431
12.8572
12.3778
-0.88
0.87
20
12.7718
12.3223
11.8780
-0.86
0.85
21
12.2280
11.8126
11.4011
-0.83
0.83
22
11.7102
11.3267
10.9459
-0.81
0.80
23
11.2172
10.8634
10.5114
-0.78
0.78
24
10.7475
10.4216
10.0964
-0.75
0.75
25
10.3000
10.0000
9.7000
-0.75
0.75
26
9.8975
9.5974
9.2980
-0.76
0.76
27
9.5129
9.2132
8.9148
-0.80
0.80
28
9.1454
8.8465
8.5496
-0.84
0.83
29
8.7942
8.4964
8.2013
-0.87
0.86
30
8.4583
8.1621
7.8691
-0.91
0.90
31
8.1371
7.8428
7.5522
-0.95
0.93
32
7.8299
7.5377
7.2498
-0.98
0.97
33
7.5359
7.2461
6.9611
-1.02
1.00
34
7.2546
6.9673
6.6854
-1.06
1.04
35
6.9852
6.7008
6.4222
-1.10
1.07
36
6.7273
6.4459
6.1707
-1.13
1.11
37
6.4803
6.2021
5.9304
-1.17
1.14
38
6.2437
5.9687
5.7007
-1.21
1.18
39
6.0170
5.7454
5.4812
-1.25
1.22
40
5.7997
5.5316
5.2712
-1.29
1.25
41
5.5914
5.3269
5.0704
-1.33
1.29
42
5.3916
5.1308
4.8783
-1.37
1.33
43
5.2001
4.9430
4.6944
-1.41
1.36
44
5.0163
4.7630
4.5185
-1.45
1.40
45
4.8400
4.5905
4.3500
-1.49
1.44
46
4.6708
4.4252
4.1887
-1.53
1.47
47
4.5083
4.2666
4.0342
-1.57
1.51
48
4.3524
4.1145
3.8862
-1.61
1.55
49
4.2026
3.9686
3.7443
-1.65
1.59
50
4.0588
3.8287
3.6084
-1.70
1.62
18
DomesticAirConditioner
YSCC18FSAADG
51
3.9206
3.6943
3.4780
-1.74
1.66
52
3.7878
3.5654
3.3531
-1.78
1.70
53
3.6601
3.4416
3.2332
-1.82
1.74
54
3.5374
3.3227
3.1183
-1.87
1.78
55
3.4195
3.2085
3.0079
-1.91
1.82
56
3.3060
3.0989
2.9021
-1.95
1.85
57
3.1969
2.9935
2.8005
-2.00
1.89
58
3.0919
2.8922
2.7029
-2.04
1.93
59
2.9909
2.7948
2.6092
-2.08
1.97
60
2.8936
2.7012
2.5193
-2.13
2.01
61
2.8000
2.6112
2.4328
-2.17
2.05
62
2.7099
2.5246
2.3498
-2.22
2.09
63
2.6232
2.4413
2.2700
-2.26
2.13
64
2.5396
2.3611
2.1932
-2.31
2.17
65
2.4591
2.2840
2.1195
-2.36
2.21
66
2.3815
2.2098
2.0486
-2.40
2.25
67
2.3068
2.1383
1.9803
-2.45
2.29
68
2.2347
2.0695
1.9147
-2.49
2.34
69
2.1652
2.0032
1.8516
-2.54
2.38
70
2.0983
1.9393
1.7908
-2.59
2.42
71
2.0337
1.8778
1.7324
-2.63
2.46
72
1.9714
1.8186
1.6761
-2.68
2.50
73
1.9113
1.7614
1.6219
-2.73
2.54
74
1.8533
1.7064
1.5697
-2.78
2.58
75
1.7974
1.6533
1.5194
-2.83
2.63
76
1.7434
1.6021
1.4710
-2.88
2.67
77
1.6913
1.5528
1.4243
-2.92
2.71
78
1.6409
1.5051
1.3794
-2.97
2.75
79
1.5923
1.4592
1.3360
-3.02
2.80
80
1.5454
1.4149
1.2942
-3.07
2.84
81
1.5000
1.3721
1.2540
-3.12
2.88
82
1.4562
1.3308
1.2151
-3.17
2.93
83
1.4139
1.2910
1.1776
-3.22
2.97
84
1.3730
1.2525
1.1415
-3.27
3.01
85
1.3335
1.2153
1.1066
-3.32
3.06
86
1.2953
1.1794
1.0730
-3.38
3.10
87
1.2583
1.1448
1.0405
-3.43
3.15
88
1.2226
1.1113
1.0092
-3.48
3.19
89
1.1880
1.0789
0.9789
-3.53
3.24
90
1.1546
1.0476
0.9497
-3.58
3.28
91
1.1223
1.0174
0.9215
-3.64
3.33
92
1.0910
0.9882
0.8942
-3.69
3.37
93
1.0607
0.9599
0.8679
-3.74
3.42
19
DomesticAirConditioner
YSCC18FSAADG
94
1.0314
0.9326
0.8424
-3.80
3.46
95
1.0030
0.9061
0.8179
-3.85
3.51
96
0.9756
0.8806
0.7941
-3.90
3.55
97
0.9490
0.8558
0.7711
-3.96
3.60
98
0.9232
0.8319
0.7489
-4.01
3.64
99
0.8983
0.8088
0.7275
-4.07
3.69
100
0.8741
0.7863
0.7067
-4.12
3.74
101
0.8507
0.7646
0.6867
-4.18
3.78
102
0.8281
0.7436
0.6672
-4.23
3.83
103
0.8061
0.7233
0.6484
-4.29
3.88
104
0.7848
0.7036
0.6303
-4.34
3.92
105
0.7641
0.6845
0.6127
-4.40
3.97
106
0.7441
0.6661
0.5957
-4.46
4.02
107
0.7247
0.6482
0.5792
-4.51
4.07
108
0.7059
0.6308
0.5632
-4.57
4.12
109
0.6877
0.6140
0.5478
-4.63
4.16
110
0.6700
0.5977
0.5328
-4.69
4.21
111
0.6528
0.5820
0.5183
-4.74
4.26
112
0.6361
0.5667
0.5043
-4.80
4.31
113
0.6200
0.5518
0.4907
-4.86
4.36
114
0.6043
0.5374
0.4775
-4.92
4.41
115
0.5891
0.5235
0.4648
-4.98
4.45
116
0.5743
0.5100
0.4524
-5.04
4.50
117
0.5600
0.4968
0.4404
-5.10
4.55
118
0.5460
0.4841
0.4288
-5.16
4.60
119
0.5325
0.4717
0.4175
-5.22
4.65
120
0.5194
0.4597
0.4066
-5.28
4.70
20
DomesticAirConditioner
YSCC18FSAADG
System Configuration
6. System Configuration
6.1 System Configuration
After the installation and test operation of the room air conditioner have been completed, it should be operated and
handled as described below. Every user would like to know the correct method of operation of the room air
conditioner, to check if it is capable of cooling (or heating) well, and to know a clever method of using it.In order to
meet this expectation of the users, giving sufficient explanations taking enough time can be said to reduce about
80% of the requests for servicing. However good the installation work is and however good the functions are, the
customer may blame either the room air conditioner or its installation work because of improper handling. The
installation work and handing over of the unit can only be considered to have been completed when its handling has
been explained to the user without using technical terms but giving full knowledge of the equipment.
21
YSCC18FSAADG
System Configuration
6.2 Instructions
Parts and Functions
1
2
3
45
6
5
7
8
22
YSCC18FSAADG
Operations
System Configuration
Base Operation
Emergency Operation:
Pi
Remote controller
SPEED
ABOVE 23OC
COOLING
26OC
NO
AUTOMATIC
BELOW 23 C
HEAT
23 C
NO
AUTOMATIC
1. Unit start
Test operation:
Test operation switch is the same as emergency switch.
Use this switch in the test operation when the room
o
AUTO
COOL
DRY
FAN
HEAT
3.Select temp.setting
Press TEMP+ TEMP- button
time the button is pressed, temp.setting
increase 1oC,if kept depressed, it will increase
rapidly
TEMP- Every time the button is pressed, temp.setting
decrease 1oC,if kept depressed, it will decrease
rapidly
Select a desired temperature.
TEMP+ Every
MED
AUTO
HI
Pos.2
Pos.3
Pos.4
Pos.5
(Auto swing)
Note
AUTO
COOL
DRY
FAN
HEAT
Pi Pi
Cautions:
When adjusting the flap by hand,turn off the unit.
When humidity is high,condensate water might occur
at air outlet if all vertical louvers are adjusted to left or
right.
It is advisable not to keep horizontal flap at downward
position for a long time in COOLor DRY mode ,
otherwise, condensate water might occur.
Note:
When restart after remote turning off, the remote
controller will automatically memorize the previous
set swing position.
23
YSCC18FSAADG
System Configuration
Operation
Sleep Operation
3. In AUTO mode
The unit operaters in corresponding sleep mode
adapted to the automatically selected operation
mode.
4. In FAN mode
It has no SLEEP function.
Note
When TIMER function is set, the sleeping function
can't be set up .After the sleeping function is set up ,
if user resets TIMER function, the sleeping function
will be cancelled;the machine will be in the state of
timing-on.
Operation Mode
1. In COOL,DRY mode
POWER/SOFT Operation
1 hr
When you need rapid heating or cooling, you can use this
function. In COOL mode, fan speed automatically takes
Rises 1OC
Note
During POWER operation, in rapid HEAT or COOL
mode , the room will show inhomogeneous temperature
distribution. Long period SOFT operation will cause
effect of not too cool or not too warm.
Rises 1OC
1 hr
Temp.setting
Unit stop
2. In HEAT mode
1 hours after SLEEP mode starts,temp will
become 2 OC lower than temp.setting.After
another 1 hours,temp decrease by 2 OC
futher.After more another 3hours,temp.rises
by 1OC futher.The unit will run for further 3
hours then stops.Temp.is lower than temp.
setting so that room temperature wont be
too high for your sleep.
Temp.setting
1 hr
NOTE:
Cooling only unit do not have displays and functions
related with heating.
Unit stop
Decreases 2OC
1 hr
Decreases 2OC
3 hrs
3 hrs
SLEEP
operation starts
Rises 1OC
SLEEP
operation stops
In HEAT mode
24
System Configuration
YSCC18FSAADG
Operation
Timer On/Off On-Off Operation
1.Press
Remote controller:
BLANK
0.5h
0.5h
0.5h
TIMER ON-OFF
0.5h
TIMER OFF-ON
to starting
Press the button for each time, setting time in the first
12 hours increased by 0.5 hour every time, after 12
hours,increased by 1 hour every time.
Press the button for each time, settiing time in the first
12 hours decreased by 0.5 hour every time, after 12
hours,decreased by 1 hour every time.
It can be adjusted within 24 hours.
4.Confirm timer setting
Healthy
airflow
downwarder
button to confirm.
Present
position
Note:
Hints:
After replacing batteries or a power failure happens, time
setting should be reset.
According to the Time setting sequence of TIMER ON or
TIMER OFF, either Start-Stop or Stop-Start can be achieved.
controller.
3.In cooling and dry, using the air conditioner for a long
time under the high air humidity, condensate water may
occur at the grille .
25
System Configuration
YSCC18FSAADG
Maintenance
For Smart Use of The Air Conditioner
Setting of proper room
temperature
Remote Controller
Indoor Body
Proper
temperature
OFF
Once every
two weeks
(Necessary installation)
ATTENTION:
The white side of the photocatalyst air purifying filter
face outside,and the black side face the unit The green
side of the bacteria-killing medium air purifying filter face
outside,and the white side face the unit.
NOTE:
26
System Configuration
YSCC18FSAADG
Cautions
WARNING
This system should be installed by a qualified HVAC professional.
Do not attempt to install the air conditioner by yourself because improper works
may cause fire, water leakage, personal injury or cleath.
WARNING
When abnormality such as burnt-small found,
immediately stop the operation button and
contact sales shop.
Check proper
installation of the
drainage securely
Use an exclusive
power source
with a circuit
breaker
STRICT
ENFORCEMENT
OFF
Connect power supply cord
to the outlet completely
STRICT
ENFORCEMENT
STRICT
STRICT
ENFORCEMENT
ENFORCEMENT
Take care not to damage
Do not use power supply
the power supply cord.
cord in a bundle.
PROHIBITION
PROHIBITION
PROHIBITION
PROHIBITION
earthing
PROHIBITION
CAUTION
Do not use for the purpose of storage of
food, art work, precise equipment,
breeding, or cultivation.
PROHIBITION
Do not install the unit near a fireplace
or other heating apparatus.
STRICT
ENFORCEMENT
Check good condition of the
installation stand
PROHIBITION
Do not place animals or plants in
the direct path of the air flow
PROHIBITION
Do not pour water onto the unit
for cleaning
PROHIBITION
PROHIBITION
Do not place any objects on or
climb on the unit.
PROHIBITION
PROHIBITION
27
PROHIBITION
System Configuration
YSCC18FSAADG
Trouble shooting
Cautions
Noise is heard
Normal
Performance
inspection
Smells are
generated.
Mist or steam are
blown out.
Specifications
The refrigerating circuit is a sealed system.
Indoor
Cooling
Outdoor
Multiple
check
Poor cooling
9. Please employ the proper power plug, which fit into the power supply
cord.
10. The power plug and connecting cable must have acquired the local
attestation.
11.In order to protect the units,please turn off the A/C first, and at least
30 seconds later, cutting off the power.
28
YSCC18FSAADG
Check Item
Check the power supply.
Check the indoor PCB
Details of Measure
Check to make sure that the rated voltage is
supplied.
Check to make sure that the indoor PCB is
broken
Equipment
operates but Diagnosis by service
does not cool, port
pressure
and Check for insufficient gas.
or does not operating
current.
heat (only for
heat pump)
Large
to make sure that the required spaces
operating
Check the installation Check
for installation (specified in the Technical Guide,
noise
and condition.
etc.) are provided.
vibrations
Description
indoor
Indoor Malfunction
E1
E2
E4
E14
Trouble shooting
Caution
Be sure to turn off power switch before connect or disconnect connector, or else parts damage may be
occurred.
CN1
CN1
29
DomesticAirConditioner
YSCC18FSAADG
on
NO
reinsert them
YES
2)
YES
Sensor is broken, replace it with new sensor
NO
30
DomesticAirConditioner
YSCC18FSAADG
NO
Replace fan motor
smoothly?
Yes
Turn power ON and operate fan
No
Does it rotate?
Yes
Is motor power voltage
NO
DC310V generated?
Replace indoor
unit PCB
Yes
Stop fan motor
Is motor control power
NO
voltageDC15Vgenerat
Replace indoor
unit PCB
Yes
Is rotation number
Is rotation number
command voltage
command pulse
DC1 6V generated?
Yes
Replace fan
motor
generated?
No
Yes
No
Replace indoor fan motor
31
DomesticAirConditioner
Capacity
YSCC18FSAADG
cooling temp.(humidity)40%
indoor temp
67
72
77
82
87
95
105
115
67/50
67/57
67/62
72/57
72/62
80/62
80/67
80/72
87/72
32
DomesticAirConditioner
Capacity
YSCC18FSAADG
cooling temp.(humidity)40%
67
72
77
82
87
95
105
115
67/50
1376
1472
1536
67/57
1440
1520
1680
67/62
1480
1536
1760
72/57
1440
1520
1680
72/62
1536
1640
1760
80/62
1536
1640
1760
80/67
1600
1712
1808
80/72
1680
1824
1936
87/72
1680
1824
1936
33
YSCC18FSAADG
Installations
9. Installation
Preparation
Selection of Installation Place
Torque wrench
(17mm,22mm,26mm)
Pipe cutter
Flaring tool
Knife
Measuring tape
Reamer
Hammer
Nipper
Hacksaw
Hole core drill
Spanner(17,19 and 26mm)
Gas leakage detector or
soap-and-water solution
Robust not causing vibration, where the body can be supported sXIFLHQWO\
Not affected by heat or steam generated in the vicinity, where inlet and outlet of the
unit are not disturbed.
Possible to drain easily, where piping can be connected with the outdoor unit.
Where cold air can be spread in a room evenly.
Nearby a power receptacle. (Refer to drawings).
Place where the distance of more than lm from televisions, radios, wireless apparatuses
and uorescent lamps can be left.
In the case of xing the remote controller on a wall, place where the indoor unit can
receive signals when the uorescent lamps in the room are in use.
Power Source
Before inserting power plug into receptacle, check the voltage without fail.
The power source is the same as the corresponding name plate.
Install an exclusive branch circuit of the power.
A receptacle shall be set up in a distance where the power cable can be
reached.Do not extend the cable by cutting it.
A Non-adhesive tape
B Adhesive tape
C Saddle (L.S) with screws
Connecting electric cable
D
for indoor and outdoor
E Drain hose
F Heating insulating material
Arrangement of piping
directions
For:HSU18VCK-W
Rear
right
Left
340
(13 1/2)
Rear left
113.5
(4 1/2)
Right
633
(24 7/8)
113.5
(4 1/2)
For:HSU24VCK-W
184
(7 1/4)
3 80
(14 15/16)
Below
580
(22 7/8)
184
(7 1/4)
Please be subject to the actual product purchased , the above picture is just for your reference.
Read this manual before installation
Explain suf ciently the operating means to the user according to this manual.
NO.0010536243
34
Installations
YSCC18FSAADG
1. Insert the drain hose into the dent of heat insulation materials of indoor unit.
2. Insert the indoor/outdoor electric cable from backside of indoor unit, and pull it
out on the front side, then connect them.
3. Coat the aring seal face with refrigerant oil and connect pipes.
Cover the connection part with heat insulation materials, cover with adhesive tape.
Accessory parts
Remote controller (1)
Cushion (4)
Drain-elbow (1)
Piping
Pipe supporting
plate
Drain hose
Selection of pipe
For 18K
Type
Liquid pipe ()
Gas pipe ()
NOTE
6.35mm(1/4)
Indoor/outdoor electric cable and drain hose must be bound with refrigerant
piping with protecting tape.
For 24K
9.52mm(3/8)
Cut away, with a nipper, the lid for piping according to the piping direction and
then bend the pipe according to the position of wall hole. When bending, be
careful not to crash pipes.
Connect beforehand the indoor/outdoor electric cable, and then pull out the
connected to the heat insulation of connecting part specially.
12.7mm(1/2) 15.88mm(5/8)
Indoor unit
1
Hang the unit body securely onto the upper notches of the
mounting plate. Move the body from side to side to verify
LWVVHFXUH[LQJ
In order to x the body onto the mounting plate,hold up
the body aslant from the underside and then put it down
perpendicularly.
1. Carry out, based on the neighboring pillars or lintels, a proper leveling for the plate
to be xed against the wall, then temporarily fasten the plate with one steel nail.
2. Make sure once more the proper level of the plate, by hanging a thread with a
weight from the central top of the plate, then fasten securely the plate with the
attachment steel nail.
3. Find the wall hole location A using a measuring tape
mounting plate
mm
(3 9/16)
A=150mm
mm
(5 7/8)
(2 3/4)
mounting plate
(5 7/8)
35mm
(5 7/8)
mm
A=150mm
(2 3/4)
Remove terminal cover at right bottom corner of indoor unit, then take
Fix to side bar and lintel a mounting bar, Which is separately sold, and then
fasten the plate to the xed mounting bar.
Refer to the previous article, When the mounting plate is Ust xed , for the
position of wall hole.
Making a Hole on the Wall and Fitting the Piping Hole Cover
1. Insert from outside the room cable into left side of the wall
Make a hole of 70 mm(2 3/4)in diameter, slightly descending to outside the wall.
Install piping hole cover and seal it off with putty after installation
Wall hole
70mm
(2 3/4)
Indoor side
Outdoor side
Thickness of wall
Insert the cord from the back side of the unit, then pull it out on the front side.
Fasten the unit wire harness to the conduit holder using the lock nut.
Position the conduit holder to its original state using screw.
[ Rear piping ]
Draw pipes and the drain hose, then fasten them with the adhesive tape
Conduit holder
Note
35
When connecting the cable, conrm the terminal number of indoor and
outdoor units carefully. If wiring is not correct, proper operation can not
be carried out and will cause damage to the units.
Installations
YSCC18FSAADG
Ensure that on dirt or debris enters the pipe.
CAUTION
Outdoor unit
Indoor unit
A
A
Indoor unit
Outdoor unit
Outdoor unit
Oil trap
Indoor unit
Max.Elevation: Amax=15 m
In case the elevation A is more
than 5m, oil trap shoud be
installed every 5~7m
Connection
2. The wiring method should be in line with the local wiring standard.
3. After installation, the power plug should be easily reached.
connections.
Use lock nuts to secure conduit tubes.
Outdoor unit
1
Attaching Drain-Elbow
Install according to
Connection of pipes
1.
and the bending radius should be 30(1 1/6) to 40 mm(1 4/7) or longer.
Flare nut
Detach the service ports cap of 3-way valve, the valve rods cap for 2-way valve
and 3-ways, connect the service port into the projection of charge hose (Iow)
for gaugemanifold. Then connect the projection of charge hose (center) for gaugemanifold into vacuum pump.
gaugemanifold, operate vacuum pump. If the scalemoves of gause (Iow) reach vacuum condition in a moment, check 1. again.
3. Vacuum for over 15min. And check the gauge which should read -0.1MPa
Spanner
Torque wrench
Pipe Diameter()
Fastening torque
Liquid side6.35mm(1/4")
18N.m
Liquid/Gas side9.52mm(3/8")
42 N.m
55N.m
60 N.m
(76 cm Hg) at Iow pressure side. After the completion of vacuuming, close the
handle Lo in gaugemanifold and stop the operation of the vacuum pump. Check
condition of the scale and hold it for 1-2min. If the scale-moves back in spite of
tightening, make aring work again, the return to the beginning of 3 .
4. Open the valve rod for the 2-way valve counterclockwise to 90 degrees.
After 6 seconds, close the 2-way valve and make the inspection of gas leakage.
36
Installations
YSCC18FSAADG
5. No gas leakage?
On Drainage
6. Detach the charge hose from the service port, open 2-way valve and 3-way. Turn
Less than
5cm
It becomes The end is imm- It waves. The gap with the There is the bad
high midway. ersed in water.
ground is too small smell from a ditch
Please pour water in the drain pan of the indoor unit, and conrm that drainage
is carried out surely to outdoor.
In case that the attached drain hose is in a room, please apply heat insulation to
it without fail.
Step 2.
Open
Gaugemanifold(for R410A)
Anti countercurrent joint
Close
Tube(for R410A)
Step 4.
Step 6.
2-way valve
2-way valve
3-way valve
R410A
1=
kg
2=
kg
1+2=
kg
3-way valve
O
Open 90
2-way valve
3-way valve
Step 7.
CAUTION
If the refrigerant of the air conditioner leaks, it is necessary to discharge all the
refrigerant. Vacuum rst, then charge the liquid refrigerant into air conditioner
according to the amount marked on the name plate.
Please do not let other cooling medium, except specied one (R410A), or air
enter into the cooling circulation system. Otherwise, there will be abnormal
high pressure in the system casuing damage and possibly personal injuries.
Clutch-type
1.Cut pipe
C o r re c t
Pipe cutting is carried out with a pipe cutter and burs must be removed.
After inserting the are nut, aring work is carried out.
1.0~1.5mm
3/76 ~1/17 inch
0~0.5mm
0~1/51 inch
in boxes
1.5~2.0mm
1/17 ~1/8 inch
2.Remove burs
4.Flare pipe
I nc o r re c t
Lean
Partial
Too outside
37
YSCC18FSAADG
Wiring Diagrams
38
DomesticAirConditioner
YSCC18FSAADG
Wiring Diagrams
1 0 .2 O u td oor
NOTE:
39
DomesticAirConditioner
YSCC18FSAADG
Wiring Diagrams
+5V
IC1
1
2
RST
1
2
3
4
57
54
MODE
P4_5/INT0
RESET
P1_3/KI3/AN11
P3_0/TRAO
P3_1/TRBO
P1_0/KI0/AN8
P0_5/AN2/CLK1
P0_4/AN3
+5V
+5V
R136
C14
4.7K- 1%
0.001UF
B5B-XH-A
58
KZ
KZ
+5V
P0_6/AN1/DA0
ST
1
2
+12V
9
56
+5V
2
1
P6_1
55
P6_2
62
61
10
+5V
VCC/AVCC
VREF
VCC/AVCC
8
59
15
+5V
VSS/AVSS
VSS/AVSS
24
45
+5V
P3_2/(INT2)
26
27
4
3
2
1
p_12
+5V
A
1
2
p_11
A0
A1
A2
GND
VCC
WP
SCL
SDA
RG2
p_11
p_12
p_42
p_43
p_46
p_47
+12V
8
7
6
5
4
3
2
1
38
8
7
6
5
4
3
2
1
+5V
35
GND
A7
A6
A5
A4
A3
A2
A1
GND
A7
A6
A5
A4
A3
A2
A1
+12
B7
B6
B5
B4
B3
B2
B1
9
10
11
12
13
14
15
16
+12
B7
B6
B5
B4
B3
B2
B1
9
10
11
12
13
14
15
16
+12V
10
9
8
7
6
5
4
3
2
1
+12V
+12V
12
13
14
15
11
25
20
P5_3/TRCIOC
P5_2/TRCIOB
P5_1/TRCIOA/TRCTRG
P5_0/TRCCLK
P5_4/TRCIOD
P1_6/CLK0
P2_3/TRDIOD0
P3_4/SDA/SCS
8
7
6
5
4
3
2
1
+12V
GND
A7
A6
A5
A4
A3
A2
A1
9
10
11
12
13
14
15
16
+12
B7
B6
B5
B4
B3
B2
B1
+12V
5
4
3
2
1
+12V
8
7
6
5
4
5
E2
E2
5
4
3
2
1
25
+5V
1
2
3
4
+5V
RG1
22
39
40
50
51
52
53
P1_5/RXD0
P1_4/TXD0
+5V
1
2
44
47
48
19
18
17
16
29
31
32
33
34
37
P2_1/TRDIOB0
P6_5/(CLK1)/CLK2
P6_4/RXD2
P0_0/AN7
P0_1/AN6
P0_2/AN5
P0_3/AN4
P1_7/TRAIO/INT1
E17
4.7uF-16V
p_1
60 GG
64 ST
63
P6_7/INT3/RXD1
8
7
6D
5
4
3
2
1
GG
21
23
P3_6/(INT1)
P1_2/KI2/AN10
P1_1/KI1/AN9
P2_4/TRDIOA1
P2_5/TRDIOB1
P2_6/TRDIOC1
P2_7/TRDIOD1
P8_5/TRFO12
P8_3/TRFO10/TRFI
P8_2/TRFO02
P8_1/TRFO01
P8_0/TRFO00
P6_6/INT2/TXD1
P4_6/XIN
1
2
3
4
5
6
7
8
9
10
28
P0_7/AN0/DA1
P3_5/SCL/SSCK
P3_7/SSO
P4_7/XOUT
OSC1
R135
1K
1
2
3
4
5
TO
+5V
1
41 DIG1
35 DIG2
30 L
P2_2/TRDIOC0
P2_0/TRDIOA0/TRDCLK
E16
4.7uF/16V
CN5
+5V
2
1
46 595-RCK
43 595-SER
42 595-SCK
49
P8_6
1
2
+5V
36
P3_3/SSI
P6_3/TXD2
P6_0/TREO
P8_4/TRFO11
B4B-XH-A
RLS4148
D31
+5V
+5V
P4_3/XCIN
P4_4/XCOUT
R5F212A7SNFA
VCC
1A-800V-500ns-FR106
1N5399
1
2
3
4
C43
0.1uF/50V
RV1
14561*
R6
7
6
5
4
3
2
1
0.1uF
1000uF-35V-105
IC10
0.1uF
470uF-16V
TLP421
VCC
4.7uF-50V-105
B7B-XH- A
ZD3
12V-1W-1N4742A
390
VS
10-1/4W
TLP421
IC4
10K
+5V
1
10K
TLP421
C
47uF-50V-105
1-1/2W
220V-N
FUSE1
T3.15A/250VAC
100K-1/ 4W
18V-1W-1N4746A
ZD1
R9
IC2
15
CN26
R59
1A-800V-500ns-FR106
1
2
3
4
D1
+12V
IC3
OUT
D7
ICE2A265
3A-200V-ER302
+5V
+5V
R10
47K-2W
330 K-2W
0.1uF-275VAC
1N5399
CH1
250 L
IN
D8
D2
LX1
32mH-0.35A-LB2271
10-1/4W
D6
8
7
6
5
220V-L
T1
8
7
6
5
1N5399
1
2
3
4
22u F-25V-105
D4
C44
1.5A-7805
18V-1W-1N4746A
27-1/4 W
1N5399
1A-800V-500ns-FR106
4.7 nF-27 5VAC
100 uF-450V-105
D3
220V-N
BCK-6-FE1901 10uF-25V-105
VCC
HS1
H-25*15
IC6
ZD2
VS
GND
SCK-4R72
4.7 uF-50V-10 5
10-1/4W
1.5K-1/4W
D5
2.2nF/250V
CX1
0.1uF-275VAC
2.2nF/250V
+12V
+12V
1
D25
RLS4148
D20
RLS4148
1
B
D21
D22
D23
RLS4148 RLS4148 RLS4148
D26
RLS4148
p_42
R61
R67 470
p_43
2
4
43
21
p_1
N
ST
WF
21
43
R81
CN54
470
R75 4.7K
R78 470
D24
RLS4148
2K
R77 4.7K
R80
2
D30
RLS4148
1
2
3
+12V
+5V
1
CN49
4.7K
3
2
1
D29
RLS4148
4.7K
D28
RLS4148
R71
R76
p_47
D27
RLS4148
B5B-XH-A
4.7K
R72 470
p_46
1
2
3
4
5
1
2
3
+5V
R104 2K
R106
47K
RG2
C10
0.1uF
1
2
3
R105 2K
R107
47K
C11
0.1uF
RG1
220V-L
40
DomesticAirConditioner
YSCC18FSAADG
Dimensional drawings
41
Center of Gravity
YSCC18FSAADG
1046
299
195
434.7
234
860
308
159.4
730
330.7
42
YSCC18FSAADG
43
Appendix
YSCC18FSAADG
Appendix
YSCC18FSAADG
44