Memory Save FS16-18
Memory Save FS16-18
ISO = 0
1
PRM 0020
(NFD) 0:
1:
bit 3
(ASI)
0:
1:
bit 0
(SB2)
0:
1:
ASI
FEED is output in punch out mode.
FEED is not output in punch out mode.
To use EIA code or ISO code.
To use ASCII code in data input mode.
1 stop bit.
2 stop bits.
18
SB2
1:
50
2:
100
3:
110
4:
150
5:
200
6:
300
See Parameter manual
necessary.
7:
600
8:
1200
9:
2400
10: H 4800
11:
9600
12:
19200 bps
for details of these parameters, if
KIND OF DATA =
FUNCTION
=
FILE NO
=
9. Press (EXEC) softkey.
Restoring Memory
Depress EMERGENCY STOP button.
Verify correct communication parameters from output procedure.
Input of CNC Parameters
1. Display to PARAMETER screen by pressing [SYSTEM] key and (PARAM)
softkey.
2. Press (OPRT) and (>) softkey.
3. Press (READ) and (EXEC) softkeys. Parameters will be input.
4. When input is complete, power the CNC OFF and ON.
Parameter No. 1815 bit 5 set to 0 will disable an alarm 310 with an
Absolute Pulse coder system.
Input of PITCH ERROR COMPENSATION data
1. Select EDIT mode.
2. Verify Parameter Write Enable = 1.
20
2.
3.
4.
5.
6.
22
Message
PLEASE TURN OFF POWER
001
TH PARITY ALARM
002
TV PARITY ALARM
010
IMPROPER G-CODE
070
NO PROGRAM SPACE IN
MEMORY
PROGRAM NUMBER
ALREADY IN USE
073
075
PROTECT
085
COMMUNICATION ERROR
086
DR SIGNAL OFF
087
BUFFER OVERFLOW
5010
END OF RECORD
Description
A parameter which requires the power off was input,
turn off power.
TH alarm (A character with incorrect parity was input.)
Correct the tape.
TV alarm (The number of characters in a block is
odd). This alarm will be generated only when the TV
check is effective.
An unusable G code or G code corresponding to the
function not provided is specified. Modify the
program.
The memory area is insufficient. Delete any
unnecessary programs, then retry.
The commanded program number has already been
used. Change the program number or delete
unnecessary programs and execute program
registration again.
An attempt was made to register a program whose
number was protected.
When entering data in the memory by using
Reader/Puncher interface, an overrun, parity or
framing error was generated. The number of bits of
input data or setting of baudrate or specification No.
of I/O unit is incorrect.
When entering data in the memory by using
Reader/Puncher interface, the ready signal (DR) was
turned off. Power supply of I/O unit is off or cable is
not connected or a PCB is defective.
When entering data in the memory by using
Reader/Puncher interface, though the read terminate
command is specified, input is not interrupted after 10
characters read. I/O unit or PCB is defective.
The end of record (%) was specified. I/O is incorrect.
Modify the program.
23