STERIVAP
STERIVAP
STERIVAP
Standard programs:
Batch Documentation
independent documentation
ofworking cycles with pressure
and temperature recording,
allowing the storage of the
last 10 records in the sterilizer
memory (up to tens of
thousands optionally SD card);
connection to aPC and storing
therecords in the computer
memory by means of the
Printer Archive software;
connection of the sterilizer
to acomputer network (LAN)
together with the software
application Ecosoft and DP 3.5;
integrated printer allowing
to select one of two graphic
outputs
1a
2b1
2c
2d
Modular System
1
3
4
14
2e
2b2
4
1b
2a
2b3
13
14
Optional Equipment
6
8
9
10
11
12
13
optional
steam source
FD steam of central source
ED own integrated steam generator
FDED combined supply of medicinal/
technical steam
thermo-degassing of supply
demi-water for the steam
generator to minimize the content
ofincondensable gases
possibility of installation for the
device for after-cooling of condensate
stainless steel valves
Air detector for continual presence
of air and incondensable gases in
sterilization chamber in the course
of each sterilization program for
maximum safety of sterilization
ascompared to routine testing programs
(Vacuum and Bowie&Dicktest)
performed only once aday before
the start of aroutine operation
(HTM2010)
special programs in chip cards
(up to 20 programs on one chip card)
additional mechanical manometers
a) on loading side
b) on unloading side
ground inner surface of the
sterilization chamber, coarseness
Ra0.8 m (Ra 32 inch), Ra 0.125 m
(Ra5inch)
tropical version for countries with
high temperature of cooling water
regulation of the device operation
control of energy maximum take-off
in case of connection of more devices
into electric network
10
12 a
Chamber Utilization
15
16
17
sterilization basket
variability in the use of aseries
of containers
sterilization of solutions
reference bottle with
temperature probe PT 100
16
12b
6
11
17
15
Validation
The ability of the sterilization processes
to be validated and recorded is one of
the conditions for their quality assurance.
Forthese pruposes, the users of STERIVAP
steam sterilizers are also offered anew
service - Validation - which allows
proving the compliance of the appropriate
standards EN 285+A2 and ENISO17665-1
with the device parameters. Thetechnical
measurement are performed by own
accredited testing laboratory.
Environmental Features
The device meets all present ecologic
requirements. It does not burden the
working conditions and environment.
Theouter cover of the insulated jacket of
the sterilization chamber is manufactured
using galvanized sheet with aquality
insulation beneath. This substantially
reduces the thermal losses therefore
saving electric energy. As standard
the equipment has abuilt-in device
Dimensions (hwd)
[mm]
Internal dim of
the chamber
10
Chamber
volume
[l]
Weight
[kg]
Total
ED
FD
ED
FD
Water [m3]
Demineralized
water [m3]**
Steam [kg]
Electric
energy
[kWh]**
Electric
energy
[kWh]*
446 1
480450700
19181200970
148
720
670
24,5/63
2/10
0,06
0,006
5,0
5,0
0,3
446 2
480450700
19181200990
148
770
720
24,5/63
2/10
0,06
0,006
5,0
5,0
0,3
559 1
509509990
191812001270
***
254
910
850
24,5/32
2/6
0,07
0,008
7,0
6,0
0,3
559 2
509509990
191812001290
***
254
920
860
24,5/32
2/6
0,07
0,008
7,0
6,0
0,3
636 1
670350700
19181000970
160
760
710
24,5/63
2/10
0,06
0,006
5,0
5,0
0,3
636 2
670350700
19181000990
160
770
720
24,5/63
2/10
0,06
0,006
5,0
5,0
0,3
666 1
700650690
19181300970
314
1030
850
38/63
2/10
0,07
0,008
7,0
6,0
0,4
666 2
700650690
19181300990
314
1100
920
38/63
2/10
0,07
0,008
7,0
6,0
0,4
669 1
700650990
191813001270
453
1130
950
47/80
2/10
0,08
0,009
9,0
7,5
0,4
669 2
700650990
191813001290
453
1200
1020
47/80
2/10
0,08
0,009
9,0
7,5
0,4
6612 1
7006501340
191813001620
610
1330
1150
48/80
3/10
0,09
0,011
11,0
9,0
0,6
6612 2
7006501340
191813001640
610
1400
1220
48/80
3/10
0,09
0,011
11,0
9,0
0,6
6618 2
7006501940
191813002240
12
885
1600
1400
66/100
4/16
0,20
0,013
15,0
15,0
1,4
969 1
1000650990
191819001270
647
1350
1200
48/80
4/16
0,12
0,012
12
11
0,7
969 2
1000650990
191819001290
647
1400
1250
48/80
4/16
0,12
0,012
12
11
0,7
9612 1
10006501340
191819001620
12
868
1700
1500
66/100
4/16
0,20
0,013
15,0
16,0
1,4
9612 2
10006501340
191819001640
12
868
2000
1800
66/100
4/16
0,20
0,013
15,0
16,0
1,4
9615 2
10006501640
191819001940
15
1060
2000
1800
76/125
4/16
0,25
0,02
20
21
1,6
9618 1
10006501940
191819002220
18
1260
2000
1800
76/125
5/16
0,3
0,025
23
23
1,7
9618 2
10006501940
191819002240
18
1260
2000
1800
76/125
5/16
0,30
0,025
23,0
23,0
1,7
9621 2
10006502300
191819002600
21
1490
2900
5/16
0,40
26,0
2,0
Model 969, 9612, 9615, 9618, 9621 with horizontally sliding door(s).
Model xxx-1 single-door type, model xxx-2 double-door type.
Model 6618, 969, 9612, 9615, 9618, 9621 steam generator is placed above or beside the sterilizer
Connecting voltage 3P/PE 400 V, 50/60 Hz, connecting voltage of the model 559 3P/N/PE 480 V, 60Hz (for the U.S.A.)
Noise level max. 78 dB.
The values may differ depending on specific charge and media parameters. Changes in the design and make reserved.
STERIVAP
External dim. of
the unit
Number
of sterilization
modules
STERIVAP hp
More information
is available direct from
our internet web site
Steam sterilizer 70 l
Exchanger steam/steam
Photo T. Benda