Discovery Service Manual v2.4 Low Res 191212

Download as pdf or txt
Download as pdf or txt
You are on page 1of 151
At a glance
Powered by AI
The key takeaways are that the service manual provides instructions for servicing different parts of the Poseidon MkVI Discovery rebreather and special precautions must be followed when working with oxygen systems.

The main sections covered in the service manual are: 1) 1st stages, octopus and LP hoses 2) Rebreather mouthpiece 3) Scrubber canister housing 4) Breathing loop 5) Electronics module and battery.

Special precautions must be taken when servicing the 1st stages since they use 100% oxygen. The instructions in the manual must be followed carefully and cleaning must be done in a clean environment using clean tools to avoid risk of fire.

SERVICE MANUAL - Discovery MKVI

Table of content
1. Safety regulations 3
2. Introduction 4
3. Tools 6
4. Preparations 8
5. 1st Stages, Octopus and LP hoses 12
6. Mouthpiece G1 43
7. Mouthpiece G2 60
8. Scrubber Canister Housing 77
9. Breathing loop 89
10. Electronics module and battery 99
11. Valves 110
12. Final assembly 121
13. Final test and upgrade 125

Revision: 2.4 Date: 121024

Approved by: JN

14. Parts lists 130

Page 2

SERVICE MANUAL - Discovery MKVI

1. Safety regulations

The instructions in this service manual must be followed in detail step by step.
Negligence can cause serious injury or even death.
Special warnings are marked with this symbol
Xstream Oxygen and Xstream Duration are used with 100% pure oxygen content.
This requires special procedures while servicing; to clean the 1st stage and to keep it
clean. Negligance to follow the instructions given in this manual introduces a risk for the
customer of having a fire which in turn can cause serious injury or even death. Servicing
the above-mentioned 1st stages, shall always be conducted in a clean environment using
clean tools, as described in section 6 and in Appendix B of the Xstream Service manual v
2.4 or later.
To enhance safety during servicing, the regulators Xstream Oxygen and Xstream
Duration shall be tested using clean air according to instructions on page 35. There is no
need to test regulators in the servicing environment using gasses with > 21% oxygen.
Servicing must only be carried out by persons who have been trained and certified
by Poseidon. Servicing Xstream Oxygen and Xstream Duration requires an additional
certification as POSEIDON OXYGEN TECHNICIAN.

Revision: 2.4 Date: 121024

Approved by: JN

Only POSEIDON original parts may be used for servicing. Where stated, POSEIDON
original tools must be used.

Whenever a Discovery MkVI is serviced, a Service Record Document should always


be created. On this document, you should note any/all suggestions of parts that you
recommend the customer to change during the service. If the customer decides not to
follow your recommendations, we strongly recommend that you get this in writing from
the customer. All documentation related to a service should be saved and stored in a safe
way.
Do not unscrew or open any screws/parts that are factory sealed. If this is done,
without written authorization and/or instructions from Poseidon Diving Systems AB, all
warranty on the unit is voided.

Page 3

SERVICE MANUAL - Discovery MKVI

2. Introduction
Service manual structure
This service manual contains servicing and repair instructions and product information for the
Poseidon MkVI Discovery rebreather and its different parts.
The service manual has been devided in to six (6) sections, each covering different parts of the
unit. The sections are:

A. 1st stages, Octopus and LP hoses

- Xstream Deep 1st stage (Diluent side)

- Xstream Oxygen 1st stage (EU version) / Xstream Duration 1st stage

- Jetstream Octopus with LP hose

- LP hoses (16 cm)

B. Rebreather mouthpiece

- Mouthpiece G1

- Mouthpiece G2

C. Scrubber Canister Housing
- CO removal cartridge housing

- End plate with sponge

- Cartridge top plate with sponge

- Round pack


E. Electronics module and battery

- Electronics module

- Primary display

- H.U.D (Heads Up Display)

- Battery with battery charger

- High pressure sensors with HP hoses

F. Valves (Only the EU version)

- 200 bar single valve, diluent gas

- 200 bar single valve, oxygen

Revision: 2.4 Date: 121024

Approved by: JN


D. Breathing loop

- Breathing loop hoses
- Counterlungs

- Water diversion manifolds

- Counterlung overboard dump valve

Page 4

SERVICE MANUAL - Discovery MKVI

2. Introduction
Symbols used through out this service manual
Icon

Description

Other information

Remove old part. Destroy and give back


to customer
Replace with new part
Visually inspect
Poseidon grease #1, article no 8515

Poseidon grease #R, article no 8516

Warning. Negligence can cause serious


injury or even death.

Service kits

Revision: 2.4 Date: 121024

Approved by: JN

Poseidon has put togeather a special service kit for the MkVI Discovery rebreather. This service
kits contains all parts that are replaced during a service and it is strongly recommended that
these kits are used.
The MkVI Discovery service kit package (article number 0009-000 / 0009-010) concists of the
following service kits:

- Art nr 4824: Service kit Xstream Duration 90 1st stage (Non EU)

- Art nr 4828: Service kit Xstream Oxygen 90 1st stage (EU)

- Art nr 4822: Service kit Xstream Deep 90 1st stage

- Art nr 3549: Service kit Jetstream Octopus

- Art nr 0009-001: Service kit 200 bar Diluent valve (only EU version)

- Art nr 0009-002: Service kit 200 bar O2 valve (only EU version)

- Art nr 0009-003: Service kit Mouth piece

- Art nr 0009-004: Service kit Breathing loop

- Art nr 0009-005: Service kit Cartridge housing

- Art nr 0009-006: Service kit Electronics unit

- Art nr 0009-007: Service kit Banjo 90 DIL

- Art nr 0009-008: Service kit Banjo 90 O2

- Art nr 0009-009: Service kit LP hose
The service kits can be bought as a complete MkVI Discovery service kit package (article
number 0009-000) or as separate service kits.
EN 144-3
The European (EU) version of the MkVI Discovery is delivered with an Xstream Oxygen 1st
stage that conforms to the EN 144-3 standard. That version has a DIN M26 connection thread.
All non-EU versions are delivered with an Xstream Duration 1st stage with a DIN G5/8
connection thread.
Page 5

SERVICE MANUAL - Discovery MKVI

3. Tools

To service the different parts of the MkVI Discovery there are a number of tools required. Some
of the tools are special tools for the 1st stages and 2nd stages and some other tools are standard
tools available in most hardware stores. Below you will find a list of all tools needed, with a
description of what it is used for.
1st stages

Octopus

Mouthp.

E-module

Other

Used to remove o-rings.

Open end wrench 6, 13-23 mm

Various open end wrenches in millimeters are


essential or assembly and dissassembly of
various things.

3460 Regulator test

Used to check or finally adjust the regulator.


o

Item

2297 O-ring remover

Description

0000-457 Testbox Mouthpiece

Used to set the Discovery mouthpiece cracking


pressure

4830 Ultra Sonic Cleaner

Used to clean all regulators. Mandatory for


Xstream Oxygen and Duration.

3771 Torque wrench

Picture

Used to set the torque on various parts of the 1:st


stages.

1246 Allen key 5 mm

Used to unscrew blindplugs and to adjust IP on


Xstream.

2706 Allen key 1,5 mm

Used to untighten and tighten the locking screw on


Jetstream Octopus and Mouth piece valve tube.

0000-368 Blind plug MP

Used to blind the inhalation CC loop connection


when adjusting the cracking pressure of the ADV.

o
o

o
o

3605 Combination tool 1

3606 Combination tool 2

Revision: 2.4 Date: 121024

Approved by: JN

2706 Adjusting tool

Used to to screw and unscrew various parts on the


first stage and second stages.

Used to to screw and unscrew various parts on the


first stage and second stages.

Used to adjust the cracking pressure on the


Jetstream Octopus and MkVI mouth piece.

4593 Allen key 2,5 mm

Used to unscrew and screw the first stage spring


cover on Xstream. (3 screws)

4591 17 mm torque wrench

Used to untighten and tighten the connection


stem on Xstream first stages. used togeather with
the torque wrench.

Screwdrivers

Philips head screwdrivers.

6010-311 O2 sensor tool

Tool used to remove the Oxygen sensors from the


electronics unit.

Page 6

SERVICE MANUAL - Discovery MKVI

3. Tools
Other

E-module

Mouthp.

Octopus

Description

1st stages

Item

Picture

Articles of consumption
8515 Oxygen grease #1

Only approved oxygen grease when lubricating


oxygen critical parts on the high pressure side.
Approved for 300 bar 60oC.

8516 Regulator grease

Used for lubrication of air version regulators.

4835 Poseidon fine clean ultra

5 litre

4837 Lint free latex gloves

4838 Hair net

You will also need the following:


- A computer (PC) with a working IrDa port/adapter
- The latest version of the PC config software (http://www.poseidon.com)
- The latest version of the Firmware (http://www.poseidon.com)
- The error codes of the most recent firmware version (http://www.poseidon.com)

Revision: 2.4 Date: 121024

Approved by: JN

Page 7

SERVICE MANUAL - Discovery MKVI

4. Preparations

Revision: 2.4 Date: 121024

Approved by: JN

Discovery MKVI parts

Page 8

SERVICE MANUAL - Discovery MKVI

Revision: 2.4 Date: 121024

Approved by: JN

4. Preparations

Before you dissassemble the unit


We recommend that before you start the dissassembly of the unit, do a Pre-Dive check to verify
if/that the unit is working or if there are any problems with it.
Remember to note any/all error messages shown during the Pre-Dive check!

Page 9

SERVICE MANUAL - Discovery MKVI

4. Preparations
Disassembly of the unit
Start the servicing of the unit by disassembling it.
Make sure the battery is disconnected from the electronics unit and that the unit is turned
off.
Remove the scrubber if it is still mounted inside the Carbon Dioxide removal cartridge
housing.
Make sure that the tank valves are closed and the 1st stages depressurized.
Breathing loop and mouthpiece
Unscrew the left and right rear breathing loop hoses from the left and right breathing hose
connections.
Unscrew the left and right rear breathing loop hoses from the left and right side water
diversion manifold (T-section).
Unscrew the left and right Front breathing hoses from the left and right side water
diversion manifold (T-section).
Unscrew the left and right Front breathing hoses from the mouthpiece.
Disconnect the HUD from the mouthpiece.
Disconnect the low pressure hose that connects the mouthpiece with the diluent 1st
stage, from the mouth piece.
Unscrew the left and right side water diversion manifolds (T-sections) from the left side
(inhalation) counterlung and the right side (exhalation) counterlung.

Revision: 2.4 Date: 121024

Approved by: JN

1st stages, low pressure hoses, Octopus, pressure sensors and tanks
Unscrew the diluent and oxygen low pressure hoses from the gas injection block.
Unscrew the diluent and oxygen low pressure hoses from the diluent and oxygen 1st
stages.
Unscrew the low pressure hose that connects the Jetstream Octopus to the diluent 1st
stage, from the diluent 1st stage.
Unscrew the high pressure sensors from the diluent and oxygen 1st stage.
Unscrew the diluent and oxygen 1st stages from the tank valves.
Open the Cylinder quick connection bands and remove the diluent and oxygen tanks.
Page 10

SERVICE MANUAL - Discovery MKVI

4. Preparations
Disassembly of the unit
Electronics unit with primary display, H.U.D and pressure sensors.
Loosen the two hand nuts that holds the
electronics unit in place.
Pull the electronics unit straight up to
detach it from the Carbon Dioxide removal
cartridge housing

Revision: 2.4 Date: 121024

Approved by: JN

Carbon Dioxide removal cartridge housing

Unscrew the four (4) base plate hand nuts that secures the cartridge end
cap to the cartridge housing. Make sure the four hand nuts are completely
disengaged from the cartridge housing threads.
Remove the end plate from the cartridge housing by pulling it straight out.

Page 11

SERVICE MANUAL - Discovery MKVI

5. 1st Stages, Octopus and LP hoses

Revision: 2.4 Date: 121024

Approved by: JN

1st Stages:

Page 12

SERVICE MANUAL - Discovery MKVI

Revision: 2.4 Date: 121024

Approved by: JN

5. 1st Stages, Octopus and LP hoses


Item #

Description

Qty

0012-028
0011-037
0003-214
4778
4878
4552
0012-132
0011-277
4579-BK
4579-GN
4579-WE

O-ring (Deep)
O-ring, viton (Duration)
O-ring. viton (Oxygen EN 144-3)
Conn. stem 1.stage 90 Xstream Deep / Duration (G 5/8)
Conn. stem 1.stage Oxygen EN 144-3
Cup type filter long Xstream 90
O-ring (Deep)
O-ring (Duration/Oxygen)
Line protector Xstream, black
Line protector Xstream, green
Line protector Xstream, white

1
1
1
1
1
1
3
3
1
1
1

6010-233

Housing 1.stage 90 Xstream

4555
0000-149
0015-059
0016-036
4758
4760
4764
4777
4563
0015-012
4762
4559
4564

Spring for ball Xstream


Ruby Ball 1.stage Xstream
O-ring (Deep)
O-ring, viton (Duration/Oxygen)
Zytel valve seat Xstream
Valve seat holder Xstream
Valve seat spring Xstream
Lower pin guide Xstream
Pin bushing 1.stage Xstream
O-ring
Upper pin guide Xstream
Actuating pin, Xstream
Roll.diaphragm 1.stage Xstream

1
1
1
1
1
1
1
1
1
1
1
1
1

4565

Pressure plate 1.stage Xstream

4763
4570-BK
4570-GN
4570-WE
4767-CE
4568

Adjust. spring 1.stage Xstream


Barrier 1.stage Xstream black
Barrier 1.stage Xstream green
Barrier 1.stage Xstream white
Cover Xstream 1st stage, chrome
Screw cover M3x10 Xstream

1
1
1
1
1
3

4798-CE

Adjustment screw, chrome

2680

Blindscrew UNF7/16

2679

Blindscrew UNF3/8

0010-353
0013-164

O-ring (Deep)
O-ring, EPDM (Duration/oxygen)

5
5

4576-BK
4576-GN
0000-150

Wheel G5/8 Xstream, black


Wheel G5/8 Xstream, green
Wheel Xstream, White (Oxygen EN 144-3)

1
1
1

3726

Valve sealing

3725

Valve piston

1180

Pressure spring

3727

Locking screw

Page 13

SERVICE MANUAL - Discovery MKVI

5. 1st Stages, Octopus and LP hoses

Revision: 2.4 Date: 121024

Approved by: JN

0100-006 Jetstream Mk3 Octopus

Page 14

SERVICE MANUAL - Discovery MKVI

5. 1st Stages, Octopus and LP hoses


# Item #

Description

Qty

0000-130

Hose Adapter

0130-002

LP hose, 9/16 - 90 cm / 35,4 inch

0010-355

O-ring

2857

Low pressure valve housing

0010-025

O-ring

3440

Valve insert

0012-007

O-ring

2974

Valve housing nut

2875

Stop screw

10 2787

Rubber plate

11 0015-019

O-ring

12 2839

Valve tube

13 0010-002

O-ring

14 2786

Servo valve, complete

15 3088

Low pressure valve, complete (parts 3 - 14)

16 3202

Mouth piece

17 1167

Locking strap

18 2711

Switch

19 0010-018

O-ring

20 3121

Housing

21 2794

Lock washer

22 2712

Diaphragm cam

23 3132

Housing, 2nd stage, incl parts 18-22, Yellow

24 2578

Diaphragm

25 2989

Cover for 2nd stage, yellow

26 2851

Screw

27 2853

Purge button

28 3104

Housing complete incl. parts 16-27, Yellow

Revision: 2.4 Date: 121024

Approved by: JN

0100-006 Jetstream Mk3 Octopus

Page 15

SERVICE MANUAL - Discovery MKVI

5. 1st Stages, Octopus and LP hoses


LP hoses

Revision: 2.4 Date: 121024

Approved by: JN

Item #

Description

Qty

0130-017 - LP hose 16 cm DIL

0130-018 - LP hose 16 cm O2 (White - EU version)

0130-019 - LP hose 16 cm O2 (Green - US version)

0130-004 - LP hose Polyurethan 9/16-18 90cm

0130-002 - LP hose Mk3 - 9/16-18 90cm (Octopus)

0010-353 - O - ring

0010-009 - O-ring

0011-276 O-ring Viton

0010-009 - O-ring

0011-006 - O-ring Viton

1
Page 16

SERVICE MANUAL - Discovery MKVI

5. 1st Stages, Octopus and LP hoses


1st stage service kits:
4822 Servicekit Xstream Deep90 Mk3 1:st stage
4758
Zytel valve seat Xstream
4552
Cup type filter long Xstream 90
0010-353 O-ring (Deep)
0012-132 O-ring (Deep)
Included
0015-059 O-ring (Deep)
0015-012 O-ring
3726
Valve sealing
0012-028 O-ring (Deep/Dive)

1 pc
1 pc
5 pcs
3 pcs
1 pc
1 pc
1 pc
1 pc

Revision: 2.4 Date: 121024

Approved by: JN

4824 Servicekit Xstream Duration90 Mk3 1:st stage (Non EU versions)


4758
Zytel valve seat Xstream
1 pc
4552
Cup type filter long Xstream 90
1 pc
4563
Pin bushing 1.stage Xstream
1 pc
0013-164 O-ring, EPDM (Duration)
5 pcs
0011-277 O-ring, viton (Duration)
3 pcs
Included:
0016-036 O-ring, viton (Duration)
1 pc
0015-012 O-ring
1 pc
3726
Valve sealing
1 pc
0011-037 O-ring, viton (Duration)
1 pc
4828 Servicekit Xstream Oxygen EN 144-3 1:st stage (EU Version)
4758
Zytel valve seat Xstream
1 pc
4552
Cup type filter long Xstream 90
1 pc
4563
Pin bushing 1.stage Xstream
1 pc
0013-164 O-ring, EPDM (Deco/Duration)
5 pcs
0011-277 O-ring, viton (Deco/Duration)
3 pcs
Included:
0016-036 O-ring, viton (Deco/Duration)
1 pc
0015-012 O-ring
1 pc
3726
Valve sealing
1 pc
4807-59 O-ring, viton EN 144-3
1 pc
0011-037 O-ring viton
1 pc
The parts that needs to be replaced during a service are described in the Servicekits section
above. Make sure that you have servicekits for the corresponding model and that you have all
special tools required available. The tools required are described in the Tools section of this
hand book.

For instructions on how to service the regulator follow the instruction below until you
reach the GO TO FINAL INSPECTION text at the end of the instruction. The instructions
in this handbook must be followed in detail step by step. Negligence can cause serious
injury or even death.

Page 17

SERVICE MANUAL - Discovery MKVI

5. 1st Stages, Octopus and LP hoses


1st stage dissassembly:
A service includes the following 5 steps:
1.
Complete disassembly of the first stage.
2.
Inspection of disassembled parts.
3.
Cleaning prior to assembly.
4. Assembly.
5.
Final inspection and adjustment.
Do not disassemble the regulator in the clean room environment. All parts shall be
taken to the clean room environment after inspection and after the pre-cleaning process
if such is needed. Otherwise you risk to contaminate the clean room environment. New
parts should be stored in its original packing until it is time for assembly.
To remove o-rings, ONLY use o-ring remover tool 2297. Make sure not to damage
o-ring and sealing surfaces!!
Parts

All first stages

Tools/Instructions

Picture

2680 Blindscrew UNF 7/16 2 pcs


2679 Blindscrew UNF 3/8 5 pcs

4568 Screw M3x10 Xstream 3 pcs


2

4767-CE Cover Xstream first


stage chrome

Revision: 2.4 Date: 121024

Approved by: JN

4763 Press. spring 1.stage


Xstream
4

4565 Pressure plate 1.stage


Xstream
5

Page 18

SERVICE MANUAL - Discovery MKVI

5. 1st Stages, Octopus and LP hoses


1st stage dissassembly:
Parts

4570-BK Barrier 1.stage Xstream


black
4570-WE Barrier 1.stage Xstream
white
4570-GN Barrier 1.stage Xstream
green
4564 Roll. diaphragm 1.stage
Xstream

Tools/Instructions

Picture

Only use fingers. Tools


may puncture the
diaphragm

Pin guide assembly

4764 Valve seat spring Xstream


9

4760 Valve seat holder Xstream


4758 Zytel valve seat Xstream

Revision: 2.4 Date: 121024

Approved by: JN

10a

4760 Valve seat holder Xstream


4758 Zytel valve seat Xstream

10b

The seat/seat holder


may also be removed
using compressed air,
as shown in the picture.

Page 19

SERVICE MANUAL - Discovery MKVI

5. 1st Stages, Octopus and LP hoses


1st stage dissassembly:
Parts

Tools/Instructions

Picture

0012-028 O-ring (Deep)


0011-037 O-ring viton (Duration)
4807-59 O-ring, viton EN 144-3
11 (Oxygen EN 144-3)
4778 Conn. stem 1.stage 90
Xstream
12 4878 Conn. stem 1.stage EN 1443 (Oxygen EN 144-3)

13

14

Revision: 2.4 Date: 121024

Approved by: JN

15

4576-BK Line protector, black


4576-GN Line protector, green
4576-WE Line protector, white

0012-132 O-ring (Deep90/Dive90)


0011-277 O-ring Viton
(Duration90)

4576-BK Wheel G5/8 black


4576- GN Wheel G5/8green
0000-150 Wheel EN 144-3
white

4552 Cup type filter long


16

Over pressure valve


3726 Valve sealing
3725 Valve piston
17 1180 Pressure spring
3727 Locking screw

1. Remove the locking


screw with a 4mm Allen
wrench. Remove the
pressure spring and the
valve piston.
2. Remove the valve
sealing from the valve
piston with an o-ring
remover.
Page 20

SERVICE MANUAL - Discovery MKVI

5. 1st Stages, Octopus and LP hoses


1st stage dissassembly:
Parts

Tools/Instructions

Picture

0000-149 Ruby ball 1.stage


Xstream
18

4555 Spring for ball Xstream


19

4559 Actuating pin, Xstream


20

4777 Lower pin guide Xstream


21
6 mm

Revision: 2.4 Date: 121024

Approved by: JN

22

4563 Pin bushing 1.stage


Xstream
Do not pull out nor replace
the Pin bushing while
servicing a Dive model.
This should only be done
while servicing Oxygen
model.

Screw in M3 screw
4568 in the pin bushing
and pull out.

0015-012 O-ring
23

24

0015-059 O-ring (Deep)


0016-036 O-ring, viton
(Duration/oxygen)

Page 21

SERVICE MANUAL - Discovery MKVI

5. 1st Stages, Octopus and LP hoses


1st stage dissassembly:
Parts

Tools/Instructions

Picture

Parts

Tools/Instructions

Picture

6010-233 Housing 1.stage 90


Xstream

1. Check sealing
surfaces

4564 Roll.diaphragm 1.stage


Xstream

1. Check for wear and


tear

2680 Blindscrew UNF7/16

1. Check O-ring sealing


surfaces

4758

Zytel valve seat Xstream

25

On blindscrew UNF 3/8


0010-353 O-ring Deep 5 pcs
0013-164 O-ring EPDM Duration
& Oxygen 3 pcs
26
On blindscrew UNF 7/16
0012-132 O-ring Deep 2 pcs
0011-277 O-ring Viton Oxygen/
Duration 2 pcs
4798-CH Adjusting screw
27

Inspection

Revision: 2.4 Date: 121024

Approved by: JN

2679 Blindscrew UNF3/8,


3

Page 22

SERVICE MANUAL - Discovery MKVI

5. 1st Stages, Octopus and LP hoses


Inspection

Parts

Tools/Instructions

4778 Conn. stem 1.stage


Xstream

1. Check O-ring sealing


surfaces

Picture

4878 Conn. stem 1.stage


Xstream EN 144-3
(Oxygen EN 144-3)

Cleaning
Xstream Deep Cleaning
Make absolutely sure Hydrochloric acid is NOT poured into the ultra-sonic cleaner. It
would then destroy the ultra-sonic cleaner and the parts attempted to be cleaned.
If corrosion or salt deposits occurs on metallic parts, immerse part in concentrated Hempocid*
or 15% Hydrochloric acid for about 10 minutes. Then rinse them thoroughly in fresh water and
blow them dry with air. The synthetic parts must not be treated with solvents and must only be
cleaned with fresh water.
*Hempocid=Acid Liquid detergent containing phosphoric acid (5-10%) and bactericide for
disinfectant cleaning

Revision: 2.4 Date: 121024

Approved by: JN

Xstream Oxygen/Duration Cleaning for Oxygen Use


The process of cleaning for oxygen use and the information given herein shall be strictly adhered
to. Only then can Poseidon guarantee the regulator will be cleaned to a cleanliness level which is
acceptable for its intended use. This process has been verified to produce hydrocarbon residual
levels less than 50mg/m2 and a particulate level less than Cleaning Test Level 100 (ASTM G 93
Spec.)
As an alternative, oxygen servicing procedures can be carried out in accordance with other
herein listed organizations standard procedures and requirements. However, the use of
cleaning agents, the order of the operating sequences and the time to treat parts during ultra
sonic cleaning as specified in this manual must be adhered to. Wherever there is a conflict
between the procedures and set of requirements, unless the other procedure represents a
greater requirement for cleanliness, this manual takes precedence. Some methods, equipment,
and detergents which are not mentioned in this manual can have a harmful or unknown effect
on materials, such as e.g. ozone cleaning systems, strong acids etc. and shall therefore be
discarded.
The other standard procedures that can be used given the limitations above are:
EAN and Oxygen Servicing Procedures, Fourth Edition (ANDI)
IANTD Gas Blender & Service Technician Program, First Edition, August 1999
MIL-STD-1330D (SH) of the 20 September 1996
The safety of your customer and yourself depends on you carefully and strictly following these instructions.
Negligence in any step can cause serious injury or even death.
You must be certified by Poseidon as oxygen technician to undertake this procedure.
Keep hands and tools clean and free from grease, except for what is required and stated in this manual.

Page 23

SERVICE MANUAL - Discovery MKVI

5. 1st Stages, Octopus and LP hoses


Cleaning
Use protective clothing to prevent dust, fingerprints, hair, and particles to contaminate.
Use only dedicated and cleaned tools.
Ensure your oxygen handling is in conjunction with national laws.
Ensure no foreign contaminants, such as e.g. liquids, grease, particulate, dust, and mist can enter into
the cleanroom area.

The cleanroom area and work environment requirements


The cleanroom area and work environment should be setup according to minimum demands
listed in Appendix D. A cleanroom area and work environment audit should be performed once
a year either by a service technician or by a from Poseidon appointed auditor. The checklist in
Appendix D should be used to make sure that all criterias are fulfilled. For detailed instructions on
how to perform and audit please refer to Appendix D.
Preparations and Pre-cleaning
1. These preparations and the pre-cleaning shall NOT be conducted in the clean room, since it
may then contaminate the clean room.
2. If any part is visibly contaminated, it shall be pre-cleaned, including the parts listed below which
shall not be ultra sonic cleaned.
3. Only undertake the pre-cleaning if you are sure you can move on to the cleaning stage
immediately after. If the parts dry between the two stages of operation, undesirable deposits can
be left on part surfaces.
4. Use IPA and a toothbrush to agitate away all visible contaminants. Rinse part(s) in municipal
running water until all visible soil, particulate and cleaning agent isremoved. When using IPA
make sure you have sufficient ventilation. Please refer to the safety instructions of the IPA.
5. Use air of any quality to blow dry.
The process below should be performed outside the cleanroom area

Revision: 2.4 Date: 121024

Approved by: JN

1. Wash your hands before this cleaning process.


2. Always ensure the UltraSonic cleaner is absolutely clean inside
3. Fill the UlraSonic cleaner with Poseidon FineClean Ultra and water in the ratio 1:5.
4.Let the UltraSonic cleaner reach its working temperature 60-70C .
5. Place all parts in the basket. The parts shall be placed so that no air is trapped inside. Turn
the part a few times under the solution until no bubbles are coming from it. Ultra Sonic cleaning
agitates away contaminants, why it is important to finally place the part so that contaminants can
drop out freely, i.e. open holes pointing down. Ensure parts are not contacting each other, since
that may reduce the cleaning effectiveness.
6. Immerse and ultra sonic clean the parts for 20-25 minutes
7. The rolling diaphragm shall only be cleaned for 10 minutes
8. Bring all parts needed to assemble the complete 1st stage to the clean room.
Page 24

SERVICE MANUAL - Discovery MKVI

5. 1st Stages, Octopus and LP hoses


Cleaning
The process below should be performed INside the cleanroom area
Rinsing and drying in the cleanroom
From this stage and through the assembly stages cleanroom clothing including gloves shall be
used.
Pick up each part from the basket and rinse carefully under running water at least 30 seconds per
part, or;
Rinse in two stages keeping the parts in the basket. Immerse the basket with the parts in another
container of at least 3 litres of clean water and agitate for at least 5 minutes. Then replace the
rinsing water with new clean water (ideally deionised, distilled, and filtrated water), and rinse for
another 5 minutes. Ensure all cavities are carefully rinsed. It is the internal rinsing which is the
most important!
Dry the parts by using a cleaned blowgun and clean air, and blow dry each part carefully.
Verification
White light
All parts shall be observed for the absence of contaminations under strong white light and for the
accumulations of lint fibres. This method will detect particulate matter in excess of 50 microns and
other contaminations in relatively large amounts. The part being examined must be recleaned
if any contamination is detected using this method. You shall have access to, and use if found
necessary, a magnifying glass or a microscope with at least x10 magnification.
Ultraviolet light (Black light)
Examine all parts in darkness using an ultraviolet light of between 3200 to 3800 Angstrom
wavelength. If a bluish-white fluorescent blotch, smear, smudge, or film is present, the pert must
be recleaned. Ultraviolet light inspection will help to verify that cleaned surfaces are free from any
hydrocarbon fluorescence.

Revision: 2.4 Date: 121024

Approved by: JN

If parts cannot be used immediately for assembly, pack in clean plastic bags to avoid parts from
being recontaminated.

Page 25

SERVICE MANUAL - Discovery MKVI

5. 1st Stages, Octopus and LP hoses


1st stage assembly:
Lubricants shall be used sparingly. Excessive quantities of lubricant can trap particulate
and other contaminants developing apotential fire hazard.
Parts marked with the symbol are parts that must be replaced at every service. New
parts should be stored in its original packing until it is time for assembly.
Parts
Tools/Instructions
4758 Zytel valve seat Xstream

Picture

0016-036 O-ring, viton


(Oxygen/Duration)

Oxygen/Duration

2a

0015-059 O-ring (Deep)

Deep/Dive

2b

0015-012 O-ring
Use bushing 4563 to install
o-ring

Revision: 2.4 Date: 121024

Approved by: JN

4763 Pin bushing 1.stage


Xstream
4

Make sure fully to the


bottom

4777 Lower pin guide


Xstream
5
3 +/- 1 Nm

Page 26

SERVICE MANUAL - Discovery MKVI

5. 1st Stages, Octopus and LP hoses


1st stage assembly:
Parts
4759 Actuating pin,
Xstream
6

4798 Adjusting screw

Tools/Instructions

Picture

Lubricate pin at top


section only. Leaving
lower end dry. Wipe off
excessive grease under
the hat.

On blindscrew UNF 3/8


0013-164 O-ring EPDM Duration
& Oxygen 3 pcs
8a

Oxygen/Duration

On blindscrew UNF 7/16


0011-277 O-ring Viton Duration
& Oxygen 2 pcs
On blindscrew UNF 3/8
0010-353 O-ring Deep 5 pcs

Deep

8b On blindscrew UNF 7/16


0012-132 O-ring Deep 2 pcs
4552 Cup type filter long

Revision: 2.4 Date: 121024

Approved by: JN

4576-BK Wheel G5/8 black


4576-GN Wheel G5/8 green
0000-150 Wheel White
10
(Oxygen EN144-3)
0011-277 O-ring Viton
(Oxygen / Duration)
11a

Duration

Page 27

SERVICE MANUAL - Discovery MKVI

5. 1st Stages, Octopus and LP hoses


1st stage assembly:
Parts
0012-132 O-ring (Deep)

Tools/Instructions
Deep/Dive

11b

12

Picture

4576-BK Line protector, black


4576-GN Line protector, green
4576-WE Line protector, white

4771 Conn. stem 1.stage 90


(Dive / Duration)
4878 Conn. stem 1.stage
13 (Oxygen EN 144-3)
Ensure line protector is correctly positioned,
with one slot facing to the bottom of the
housing
Torque setting 30 Nm

0011-037 O-ring viton (Duration)


4807-59 O-ring viton (Oxygen
14a EN 144-3)

0012-028 O-ring (Deep)

Revision: 2.4 Date: 121024

Approved by: JN

14b

4555 Spring for ball Xstream


15

Wide end facing upwards,


towards the ball.
0000-149 Ruby Ball

16

Page 28

SERVICE MANUAL - Discovery MKVI

5. 1st Stages, Octopus and LP hoses


1st stage assembly:
Parts
Tools/Instructions
4760 Valve seat holder Xstream
4758 Zytel valve seat Xstream

Picture

17

4764 Valve seat spring Xstream


18

Pin guide assembly

Oxygen/Duration

19a
6 +/- 1 Nm
Pin guide assembly

Deep

19b
6 +/- 1 Nm
4564 Roll. diaphragm 1.stage
Xstream

21

4570-BK Barrier 1.stage black


4570-WE Barrier 1.stage white
4570-GN Barrier 1.stage green

You should see the


marking This side up on
the barrier.

Revision: 2.4 Date: 121024

Approved by: JN

20

Page 29

SERVICE MANUAL - Discovery MKVI

5. 1st Stages, Octopus and LP hoses


1st stage assembly:
Parts
4565 Pressure plate 1.stage
Xstream

Tools/Instructions

Picture

22

4763 Adj. spring 1.stage


Xstream
23

4567-CE Cover Xstream first


stage, chrome
24

4568 Screw cover M3x10


Xstream 3 pcs

Oxygen/Duration

25a

4568 Screw cover M3x10


Xstream 3 pcs

6 +/- 1 Nm
Deep

25b

Revision: 2.4 Date: 121024

Approved by: JN

2680 Blindscrew UNF 7/16


2 pcs

6 +/- 1 Nm

26 2679 Blindscrew UNF 3/8 5 pcs


Over pressure valve assembly

27

3726 Valve sealing


3725 Valve piston
1180 Pressure spring
3727 Locking screw

1. Attach the new valve


sealing to the valve piston
and place the valve piston
in the OP valve hole with
the seal towards the
housing.
2. Place the pressure
spring in the valve piston
and tighten the locking
screw with a 4 mm Allen
key.

Page 30

SERVICE MANUAL - Discovery MKVI

5. 1st Stages, Octopus and LP hoses


LP hose inspection:
All LP hoses and parts of LP hoses should be checked for damages.
If a hose shows signs of damage it should be replaced.

5. 1st Stages, Octopus and LP hoses


LP hose o-ring replacements:
Parts

Tools/Instructions

0130-004

LP hose Polyurethan Replace the o-rings.


9/16-18 90cm

0130-002

LP hose Mk3 - 9/1618 90cm (Octopus)

0010-353
0130-004

O-ring
LP hose Polyurethan Replace the o-rings.
9/16-18 90cm

0130-002

LP hose Mk3 - 9/1618 90cm (Octopus)

0010-009
0130-018

O-ring
LP hose 16 cm O2
Replace the o-ring.
(White - EU version)

0130-019

LP hose 16 cm O2
(Green - US version)

0011-276
0130-017

O-ring
LP hose 16 cm DIL

Approved by: JN
Revision: 2.4 Date: 121024

Replace the o-ring.

Picture

0010-353
0130-018

O-ring
LP hose 16 cm O2
Replace the o-ring.
(White - EU version)

0130-019

LP hose 16 cm O2
(Green - US version)

0011-006
0130-017

O-ring
LP hose 16 cm DIL

0010-009

O-ring

Replace the o-ring.

Page 31

SERVICE MANUAL - Discovery MKVI

5. 1st Stages, Octopus and LP hoses


Parts marked with the symbol are parts that must be replace at every service. New
parts should be stored in its original packing until it is time for assembly.

1st stage settings and final inspection:


Property 1st stage

Setting SI units

Setting common units

Setting US units

P1
P2
P3
P4@P1.
P4@P3.
P5
i
R
Q
Internal leaktightness

30 MPa
>750 kPa
2 MPa
Min 800 kPa - Max 850 kPa
Min 800 kPa - Max 850 kPa
>750 kPa
+/- 110 kPa
max 100 kPa
0.12 m3/h

300 bar
> 7.5 bar
20 bar
Min 8.0 bar - Max 8.5bar
Min 8.0 bar - Max 8.5bar
> 7.5 bar
+/- 1.1 bar
max 1 bar
2 L/min
12 ml/h*

4351 psi
>109 psi
290 psi
Min 116 psi - Max123 psi
Min 116 psi - Max123 psi
>109 psi
+/-16 psi
max 15 psi
0.07 ft3/min

Property 2nd stage


CP (cracking pressure)

Setting SI units

Setting common units

Setting US units

-274 Pa to - 392 Pa

-28 to -40 mm.w.c

-1.1 to -1.6 inch of water

* Corresponds to a pressure climb of


0,01 bar/min for a regulator with a 70
cm hose.

Method for regulators cleaned for oxygen use


Unless you do have access to an oxygen cleaned test station, you must ensure you do not
re-contamine the regulator when doing the final adjustment and setting. Re-contamination can
be caused by e.g. contaminated test gas, contaminated gauge fittings, contaminated regulator
connection, contaminated test station pipings etc.

Revision: 2.4 Date: 121024

Approved by: JN

First stage setting:


1) Slowly open cylinder valve
2) Check IP
3) Close valve
4) Purge
5) Adjust IP (1/2 turn = 1.5 bar)
6) Open valve
7) Check IP (loop to 3)
8) Close valve
9) Purge
10) Place the Calibrated sticker on the
adjustment screw

2. 7.
4. 9.

5.
1. 3.
6. 8.

Page 32

SERVICE MANUAL - Discovery MKVI

5. 1st Stages, Octopus and LP hoses


1st stage settings and final inspection:
Method for all other regulators

System check:
1) Open left valve 20 bar
2) Close left valve 20 bar
3) Purge

1.

2.

Revision: 2.4 Date: 121024

Approved by: JN

3.

First stage setting:


1) Open right valve HP (200-300bar)
2) Purge
3) Check IP (go to 9 if OK)
4) Close right valve
5) Purge
6) Adjust IP (1/2 turn = 1.5 bar)
7) Open right valve
8) Check IP (loop to 4)
9) Close right valve
10) Purge
11) Open left valve (20 bar)
12) Check IP
13) Close left valve
14) Purge
15) Place the Calibrated sticker on the
adjustment screw

Page 33

SERVICE MANUAL - Discovery MKVI

5. 1st Stages, Octopus and LP hoses


1st stage technical data:
Torque table:
Part subject to torque Newton Meter
wrench use
Nm
Blind screws
6 +/- 1

Inch Pounds
Inch-lbs
53 +/- 9

Foot Pounds
Ft-lbs
4.4 +/- 0.7

Kilogram Meter
Kgm
0.6 +/- 0.1

First stage
connection stem to
body
Centre piece

30 +/- 2

265 +/- 18

22 +/-2

3 +/- 0.2

6 +/- 1

53 +/- 9

4.4 +/- 0.7

0.6 +/- 0.1

Lower centre piece

3 +/- 1

27 +/- 5

2.2 +/- 0.4

0.3 +/- 0.05

Cover screws 1
stage

6 +/- 1

53 +/- 9

4.4 +/- 0.7

0.6 +/- 0.1

st

Product data:
Deep
Air / Trimix
Duration
Air / Oxygen
Oxygen
Air / Oxygen
300 bar (4351 psi)

Maximum working
pressure
Cold water performance Exceeding EN 250 requirements for cold water
use
Approvals
Type Approved acc. to EU Directive Personal
Protective Equipment 89/686/EEC
Applicable Performance EN 738-1, clause 6.6, 6.6.2
Standards
NORSOK U-101 clause 5.2-5.5, 5.9
EN 250:2000
Deep
No
Duration
Yes
Oxygen
Yes
Deep
Nitrile, EPDM,Viton
Duration
Viton, EPDM, Nitrile
Oxygen
Viton, EPDM, Nitrile
Lubricants
Poseidon 1; BAM appr. 270 bar @ 100C
Poseidon R; silicone oil.
Deep
Black
Duration
Green
Oxygen
White
Warranty
24 months

Revision: 2.4 Date: 121024

Approved by: JN

General:

Page 34

SERVICE MANUAL - Discovery MKVI

5. 1st Stages, Octopus and LP hoses


1st stage technical data:
Product data: (cont.)
1st stage
Flowrate (l/min)
>4000 l/min (>141 scfm)
Nominal inter-stage pressure 8.5 bar (123 psi)
Weight
Deep
1100 g
Duration
Oxygen
Anti-Freeze protection
Built in T.D.A
Technique
Rolling diaphragm
Valve technique
Ball valve
Seat material
Zytel
Test pressure
450 bar (6526 psi)
Ports
Deep
5 IP (UNF 3/8)
2 HP (UNF 7/16)
Duration
5 IP (UNF 3/8) /
Oxygen
2 HP (UNF 7/16)
Deep
DIN 477, G5/8
Yoke adapter available
Duration
DIN 477, G5/8
Yoke adapter available
Oxygen
EN 144-3/M26x2
Material
Brass, plastics, stainless steel
Hose
Burst pressure
>100 bar (1450 psi)
Pull strength
>1000 Newton (225 lbf)
Material
Reinforced NBR/SR
Safety inspection holes
Both ends
Wear protecting crimps
Both ends
Oxygen cleaned
Available

Revision: 2.4 Date: 121024

Approved by: JN

Conversion table:
Known

Unknown

Multiply by

Bar

psi

14.5

Psi

bar

0.07

mm.w.c

mbar

0.1

mbar

mm.w.c

10

litre

ft

ft3

litre

0.0353
28.32

ft

3.28

ft

0.305

Nm

poundfoot

0.7375

Poundfoot

Nm

1.356

Page 35

SERVICE MANUAL - Discovery MKVI

5. 1st Stages, Octopus and LP hoses


0100-002 Jetstream Mk3 Octopus
Disassebly
Parts

0130-002

1
3088

3202
1167

Tools/Instructions

Picture

Disconnect the low pressure hose from the


second stage.
Remove the low pressure valve from the housing
(15) with a screwdriver.Make sure the servo
valve needle is not bent. Be sure to hold the low
pressure valve carefully, to avoid dropping it
(see figure).

Cut off the locking strap (17) with cutting pliers.


Remove the mouth piece (16).

2851
Unscrew the 4 screws (26) with a 3.5 mm
screwdriver.

4
2578
2989

Remove the cover (25) and the diaphragm (24).

2853

6
2711
0010-018
2794
2712

Approved by: JN
Revision: 2.4 Date: 121024

Remove the purge button (27).

IMPORTANT
The switch should not be removed if it is
undamaged.
Removal:
1. Pull out the diaphram cam (22).
2. Cut off the switch (18) with a pair of cutting
pliers close to the locking washer (21). Remove
the switch.
3. Remove the o-ring (19).

Page 36

SERVICE MANUAL - Discovery MKVI

5. 1st Stages, Octopus and LP hoses


0100-002 Jetstream Mk3 Octopus
Disassebly
Parts
2786

Tools/Instructions

Picture

Remove the servo valve (14).


2875
0015-019
2839
0010-002
2787

Unscrew the stop screw (9) and remove the


valve tube (12). Remove the o-rings (11) (13)
with an o-ring remover.Make sure the sealing
surfaces are not damaged.
Remove the rubber plate (10).

2857
Place the valve housing in the
tool. Unscrew the valve housing
(4) with a special spanner.

10

0012-007
Remove the o-ring (7) with an oring remover.
Make sure the sealing surfaces are not
damaged.

11

3440

12

Remove the valve insert.

Remove the o-rings (5) (3) with an o-ring


remover.Make sure the sealing surfaces are not
damaged.

13

Revision: 2.4 Date: 121024

Approved by: JN

0010-355
0010-025

Page 37

SERVICE MANUAL - Discovery MKVI

5. 1st Stages, Octopus and LP hoses


0100-002 Jetstream Mk3 Octopus
Cleaning
When servicing the regulator all parts in service kit # 3549 should be replaced.
CLEANING:
If corrosion or salt deposits occurs, place all metal parts concentrated Hempocid* or 15%
Hydrochloric acid for about 10 minutes.Then, rince the parts thoroughly and blow dry with air.
The synthetic parts in the second stage must not be treated withsolvent.They shall be cleaned in
freshwater only.
*Hempocid = Acid Liquid Detergent Containing phosphoric acid (5 - 10%) and bactericid for
desinfectant cleaning.

Before assembly, check the following


Parts
2578

Tools/Instructions

Picture

Diaphragm (24). Check that the sealing surface


of the diaphragm is even. Also check that there
are no holes in the diaphragm and that the
diaphragm washer is properly fixed in position.

3202

The mouth piece (16). Make sure there are no


cracks.
2853

The purge button (27).Make sure


there are no cracks. Check to make sure
the spring is undamaged.

2786

Servo valve (14). Check to make sure that the


valve bar is not bent.
The switch: Put the switch into - and +position.
It should be moved rather slowly, control the
position of the diaphragm and that it is properly
tighten.

Revision: 2.4 Date: 121024

Approved by: JN

Page 38

SERVICE MANUAL - Discovery MKVI

5. 1st Stages, Octopus and LP hoses

0100-002 Jetstream Mk3 Octopus


Assembly
Parts

0010-355
2857

Mount the o-rings (5,3) on the valve housing (4).


Use the tools. See picture.

Tools/Instructions

2857
3440

2857
0012-007
2974

Picture

Install the valve insert (6) in the valve housing


(4). Do not use any lubricant on the valve insert
(4), use only soap and water.
Place the o-ring (7) in the groove of the valve
insert (6).
Lubricate the thread. Install the valve housing
nut (8).

2857
2974
Place the valve housing in the handle. Tighten
with a tool. See picture.

Revision: 2.4 Date: 121024

Approved by: JN

0015-019
2839
0010-002

Install the o-rings (11,13) on the valve tube (12).


Lubricate the threads and the o-rings.

2839

Screw in the valve tube (12) until about 2 mm


space remains as illustrated.

Page 39

SERVICE MANUAL - Discovery MKVI

5. 1st Stages, Octopus and LP hoses


0100-002 Jetstream Mk3 Octopus
Assembly
Parts
2857
2787

Tools/Instructions
Install the rubber plate (10). Screw in
the stop screw (9). Tighten the stop screw to a
point where you can still turn the valve tube (12).

Picture

2786
Screw the servo valve (14 ) on to valve tube
(12).Tighten up. Be careful not to bend the valve
needle.

2711
0010-018

SWITCH (Only if the switch is damaged)


Fit in o-ring (19) and lubricate it.

Fit in the switch with the narrow part against


the - minus sign on the second stage valve. See
Picture.

2711
0010-018
2794
2712

Revision: 2.4 Date: 121024

Approved by: JN

10

11

Install the locking washer (21) on the switch (18).


Press it on a drift. Tighten the locking washer so
that there is sufficient resistance when
setting the switch.
Fix the diaphragm cam (22) upon the switch
(18). Set switch at - (minus), press the
diaphragm cam into correct position per the
diagram.
The distance from the top of the diaphragm
cam to the housing should be 2 mm, concerns
diaphragm of silicone rubber, see diagram.
Carefully push diaphragm cam into the right
position. Note the cam should be pushed slowly
on to the switch so that the switch is not moved.

Page 40

SERVICE MANUAL - Discovery MKVI

5. 1st Stages, Octopus and LP hoses


0100-002 Jetstream Mk3 Octopus
Assembly
Parts
12

2989
2853

Tools/Instructions

Picture

Fit the purge button in the cover (25) for the


second stage.Make sure that the spring is
undamaged.

2578
Position the diaphragm (24) with the diaphragm
washer facing down wards and the hole
positioned as illustrated.

13

2989
2851 x 4

14

3202
1167

15

Position the cover (25) for the second stage


according to the adjacent illustration. Lubricate
the screw and tighten (27) with a screwdriver.

Install the mouth piece (16) and the locking strap


(17). Tighten up and cut off with plastic band
pliers.

Checking the second stage for leaks:

Revision: 2.4 Date: 121024

Approved by: JN

16

Place the mouth piece against your lips and


cover the low pressure hose connection with
your thumb and inhale lightly.This will create a
partial vacuum inside the second stage. If the
pressure does not equalize in 5 second stage
leaks. Then you need to check to make sure you
have mounted all o-rings.

Page 41

SERVICE MANUAL - Discovery MKVI

5. 1st Stages, Octopus and LP hoses


0100-002 Jetstream Mk3 Octopus
Adjustment of the inhalation resistance
Tools/Instructions
Connect the Xstrean Depp DIL 1st stage to the test equipment.

Connect the test manometer hose to one of the


low pressure outlets..
Connect the Jetstream Octopus to one of the
low pressure outlets on the Xstream Deep DIL 1st stage.

Pressurize the 1st stage at maximum tank pressure.


Connect the oval connecting pipe on the
inhalation resistance gauge to the mouth-piece
on the Octopus.

Test-breathe very carefully. Check the reading of


the gauge needle, which should rise to 35-40
mm/vp and then move back.The turning point
reading equals the inhalation resistance. If the
reading is too low, screw the valve tube away
from the diaphragm as shown in the picture below.
If the reading is too high, screw the valve tube
towards the diaphragm.
Tighten up the stop screw.

Revision: 2.4 Date: 121024

Approved by: JN

Repeat the inhalation test again to verify that the inhalation resistance remains the same
after the stop screw has been tightned.

Page 42

SERVICE MANUAL - Discovery MKVI

6. Mouthpiece G1
Mouthpiece: 6011-001

Description

6010-000

4532

Qty

Mouthpiece house assembly

Mouthpiece AIR

6010-005

OC outlet

0000-130

Hose adapter

1167

Cable tie

Revision: 2.4 Date: 121024

Approved by: JN

Item # Article #

Page 43

SERVICE MANUAL - Discovery MKVI

6. Mouthpiece G1
Mouthpiece: House assembly

Revision: 2.4 Date: 121024

Approved by: JN

Item # Article #

Description

Qty

6010-001

Mouthpiece house

4536

Diaphragm cover

4533

Membrane with washer

0000-232

Membrane mouthpiece

6010-013

Membrane holder complete

6010-010

DV Switch

Page 44

SERVICE MANUAL - Discovery MKVI

6. Mouthpiece G1
Mouthpiece: DV Switch (6010-010)

Description

Qty

6010-104

Lock nut

0000-602

Plastic washer

6010-012

Barrel magnet

0015-245

O-ring

6010-114

Helix block

0010-120

O-ring

Revision: 2.4 Date: 121024

Approved by: JN

Item # Article #

Page 45

SERVICE MANUAL - Discovery MKVI

6. Mouthpiece G1
Mouthpiece: Low pressure valve MkVI (0005-000)

Item # Article #

Description

Qty

0000-148

Valve house nut

0011-278

O-ring

0012-016

O-ring

0013-001

O-ring

0013-009

O-ring

0013-351

O-ring

2787-07

Rubber plate

2857

Low pressure valve house

2875

Stop screw

10

3440 07

Valve insert

11

2839

Valve tube

12

2786 07

Servo valve

Revision: 2.4 Date: 121024

Approved by: JN

Page 46

SERVICE MANUAL - Discovery MKVI

6. Mouthpiece G1
Mouthpiece: Membrane holder complete (6010-013)

Description

Qty

0000-324

Membrane holder

0010-032

O-ring

0000-323

Membrane Check valve

Revision: 2.4 Date: 121024

Approved by: JN

Item # Article #

Page 47

SERVICE MANUAL - Discovery MKVI

6. Mouthpiece G1
Mouthpiece:
Disassembly
Parts
Remove the LP hose from the
hose adaptor.

Tools/Instructions

Picture

Remove the Diaphragm cover


(4536) from the mouth piece
housing.
Remove the membrane with
washer (4533) from the mouth
piece housing.
Remove the OC outlet (6010-005)
from the mouth piece housing.

Do not use force when


removing the OC outlet.

Remove the DV Switch (6010010) from the mouth piece


housing by unscrewing the Lock
nut (6010-104). When the lock nut
is un-screwed, turn the DV switch
upwards until the DV switch points
towards the divers face.
Then pull the DV switch out.
Be carefull NOT to
damage the barrel
magnet!

Revision: 2.4 Date: 121024

Approved by: JN

Unscrew the servo valve from the


valve tube.
6

Remove the O-ring (0015-245)


7

Page 48

SERVICE MANUAL - Discovery MKVI

6. Mouthpiece G1
Mouthpiece:
Disassembly
Parts
0010-120 O-ring
8

6010-114 Helix block


9

Tools/Instructions

Picture

Remove the o-ring from


the barrel.

Unscrew the helix block


and then slide it off the
barrel.

6010-257 Plastic washer


Remove the plastic
washer from the barrel.

10

6010-104 Lock nut


11

12

6010-122 Barrel

Slide the lock nut off the


barrel.

Use a set of pliers to remove the


Membrane holder (6010-013).
Start with the exhale side.

Revision: 2.4 Date: 121024

Approved by: JN

Grab with the pliers and pull


gently.
Push the inhale side out.
13

Remove the o-ring (0100-032)


from the two membrane holders
14

Page 49

SERVICE MANUAL - Discovery MKVI

6. Mouthpiece G1
Mouthpiece:
Disassembly
Parts
Remove the hose adaptor from
the DV switch barrol

Tools/Instructions

Picture

15

Remove the Low pressure valve


from the mouth piece housing.
16

17

Remove the stop screw (2875)


that holds the valve tube locked in
the valve house nut.

Unscrew the valve tube (4902)


from the valve house nut.
18

Remove the 0013-001 O-ring from


the valve tube.

Revision: 2.4 Date: 121024

Approved by: JN

19

Remove the 0013-351 O-ring from


the valve tube.
20

21

Unscrew the valve house nut


(0000-148) from the low pressure
valve housing (2857).

Page 50

SERVICE MANUAL - Discovery MKVI

6. Mouthpiece G1
Mouthpiece:
Disassembly

22

Parts
Remove the rubber plate (2787)
that is located under the stop
screw (2875).

Tools/Instructions

Picture

Remove the O-ring (0013-009)


23

Remove the O-ring (0012-016)


24

25

Remove the o-ring (0011-278)


from the inside of the low pressure
valve housing.

Revision: 2.4 Date: 121024

Approved by: JN

26

Remove the valve insert (3440)


from the low pressure valve
housing by pushing it out.

Page 51

SERVICE MANUAL - Discovery MKVI

6. Mouthpiece G1
Mouthpiece:
Inspection
Parts
Servo valve (2786 07)

Inspect
Make sure that the tip is not
bent.

Valve tube (4902)


Check O-ring sealing
surfaces

Valve insert (3440)


3

1. Ensure no circular cuts on


bladder surface.

Picture

2. Check O-ring sealing


surface.
0000-232 membrane

Make sure the membrane


isnt damaged.

Replace if damaged.
0000-323 Membrane Check
valve
5

Replace if damaged.

Approved by: JN
Revision: 2.4 Date: 121024

Make sure the check valves


arent damaged.

4532 Mouthpiece AIR

Check for damage and


holes.

replace if damaged.

Page 52

SERVICE MANUAL - Discovery MKVI

6. Mouthpiece G1
Mouthpiece:
Cleaning
If corrosion or salt deposits occurs on metallic parts, immerse part in concentrated Hempocid*
or 15% Hydrochloric acid for about 10 minutes or wash them in an ultra sonic washer.
Then rinse them thoroughly in fresh water and blow them dry with air. The synthetic parts must
not be treated with solvents and must only be cleaned with fresh water.
*Hempocid=Acid Liquid detergent containing phosphoric acid (5-10%) and bactericide for
disinfectant cleaning

Revision: 2.4 Date: 121024

Approved by: JN

Bag the parts below in a plastic bag for later assembly. These parts shall not be ultra
sonic cleaned but we recommend that you soak these parts in Gigasept and then rinsed in fresh
water.

4536 - Diaphragm
cover

4533 - Membrane
with washer

4532 - Mouthpiece

0000-323 Membrane Check


valve

0000-232 - Membrane
mouthpiece

6010-122 - Barrel with


6010-010 DV Switch

6010-116 - membrane
holder.

6010-005 - OC Outlet

6010-001 - Mouthpiece housing

0000-257 - Washer
Page 53

SERVICE MANUAL - Discovery MKVI

6. Mouthpiece G1
Mouthpiece:
Assembly
Parts

Tools/Instructions

0011-278

Replace Picture

O-ring, viton

3440

Valve insert

Do not use lubricant on the


valve insert.
Only use soap and water.
R

0012-016 O-ring

0013-009 O-ring

0000-148

Vavle housing
nut

Revision: 2.4 Date: 121024

Approved by: JN

3 +/- 1 Nm

0013-351 O-ring
6

0013-001 O-ring

Page 54

SERVICE MANUAL - Discovery MKVI

6. Mouthpiece G1
Mouthpiece:
Assembly
Parts

Tools/Instructions

Replace Picture

4902 Valve tube


8

2787 Rubber plate

2875 Stop screw


10

4545 Servo valve


11

6010-104 Lock nut


12 6010-122 Barrel

Revision: 2.4 Date: 121024

Approved by: JN

6010-257 Plastic washer


13

Thread the plastic washer


on to the barrel. Use the
grove in the washer to slide
over the knobs.

6010-114 Helix block

Thread the helix block on to


the barrel. Then screw it on
to the small knobs on the
barrel.

0010-120 O-ring

Thread the o-ring on to the


barrel.

14

15

Thread the lock nut on to the


barrel.

Page 55

SERVICE MANUAL - Discovery MKVI

6. Mouthpiece G1
Mouthpiece:
Assembly
Parts

Tools/Instructions

0015-245 O-ring

Place the o-ring in the


groove. Apply a lot of
lubricant!

Replace Picture

16

R
0005-000 LP valve
17 6010-010 DV Switch
0000-130 Hose adapter

Insert the LP valve in to


the DV Switch. The locking
screw on the LP valv should
point in the oposite direction
of the DV Switch lever.
Attach the hose adpter to
the DV switch assembly.

18

Revision: 2.4 Date: 121024

Approved by: JN

Push the assebled DV


The 0015-245 O-ring should
Switch and LP valve in to the
be facing upwards and the
mouth piece housing.
19
DV Switch lever should be
pointing towards the divers
face.
When the assebled DV
Switch and LP valve is
pushed half way in to the
20 mouth piece housing, turn
the DV switch lever forward,
to OC position.

The guiding pin on the helix


block, closest to the DV
Switch lever should align
with the groove marked No
1. When aligned, push the
DV switch assembly in to
position.

Start attaching the DV switch


assembly to the mouth piece As you turn the lock nut,
housing by fastening the lock push the DV valve assembly
21 nut.
in to the mouth piece
housing.

22

When the lock nut has


grabbed on to the threads of
the mouthpice housing, turn
the DV switch to CC position
and make sure the lock nut
is tightned.
Page 56

SERVICE MANUAL - Discovery MKVI

6. Mouthpiece G1
Mouthpiece:
Assembly
Parts

Tools/Instructions

6010-116 membrane holder


with membrane.

Start with the inhale


membrane. Push the
membraneholder in to the
mouthpiece housing. The
membrane should be on
the inside of the membrane
holder.

6010-116 membrane holder


with membrane.

Do the same with the exhale


membrane. Note that the
membrane should be on the
outside of the membrane
holder.

23

24

Replace Picture

4536 Diaphragm cover


4533 membrane with washer Push the membrane in to
the mouth piece housing.
25
Then snap on the diaphragm
cover.
6010-005 OC cover
Snap the OC cover back on
to the mouth piece housing.

26

27

Assembly of the mouthpiece


is now complete.

Revision: 2.4 Date: 121024

Approved by: JN

6011-001 Mouthpiece

Page 57

SERVICE MANUAL - Discovery MKVI

6. Mouthpiece G1
Mouthpiece:
Adjustment and final inspection
Action

Attach the assembled


mouthpiece to a 1st stage
that is connected to a test
box.

Make sure the 1st stage


is set to an intermediate
pressure of 8,5 bar / 123,25
psi

Loosen the stop screw just


enough to allow the valve
tube to move.

Adjust the cracking pressure By turning the valve tube


of the LP valve by turning the upwards, you move the
valve tube up or down.
servo valve closer to the
4533 membrane, lowering
the cracking pressure.

While still in OC mode.

Use the 2705 Adjustment


tool.
Adjust the valve tubing to a
position that you think will
give the desired cracking
pressure of 30 cm w.c.
Tighten the stop screw on
the LP valve houing nut

Approved by: JN
Revision: 2.4 Date: 121024

Picture

Set the mouth piece to Open If you look in to the mouth


Circuit (OC)
piece hole, you should see
the locking screw on the LP
valve insert.
Loosen the locking screw on
the LP valve housing nut.

Tools/Instructions

Turn the DV switch over to


Closed Circuit (CC) mode.
6

While in CC mode:
Hold the mouthpiece-part of
the cracking pressure gauge
tight to the outlet of the
mouthpiece.
Block the inhalation
membrane opening.

Page 58

SERVICE MANUAL - Discovery MKVI

6. Mouthpiece G1
Mouthpiece:
Adjustment and final inspection
Action

Take a few rather slow


and long inhalations from
the mouthpiece part and
simultaneously check the
pressure gauge needle.
The inhalation membrane
must be blocked during this
action.

Tools/Instructions

Picture

It shall during inhalation


reach a level of 30 cm.w.c,
and at the end of the
inhalation decrease again.

If the reading is too high or


too low, turn the DV Switch
over to OC mode and
loosen the locking screw on
the valve housing nut.
Adjust the valve tube and
servo valve.

.
9

Screw the valve tube and


servo valve closer to the
diaphragm to lower the w.c.
To increase the w.c,
screw them away from the
diaphragm.

Revision: 2.4 Date: 121024

Approved by: JN

Repeat Action #7, #8 and


#9 untill the correct cracking Once 30 cm w.c has been
pressure of 30 cm w.c has
set, do a final test with
10 been set.
the locking screw firmly
tightened.

11

Cracking pressure in OC
mode.

Disconnect the mouthpiece


from the test box 1st stage.
12

The cracking pressure in OC


mode is not set but it should
be between 30 - 70 mm w.c.
Release the pressure
between the 1st stage and
moputhpiece and disconnect
the LP hose from the 1st
stage.
Adjustment is completed.

Page 59

SERVICE MANUAL - Discovery MKVI

7. Mouthpiece G2
Mouthpiece: 0005-055
Identification
The G2 version of the MKVI mouthpiece is identified by the different Lock nut (part #0000-427)
and Mouthpiece plastic washer (part #0000-293) compared to mouthpiece with article number
6011-001. Also, the serial number marking on the mouthpiece starts with G2.

G1 Lock nut

G2 Lock nut

The mouthpiece G2 was delivered with MKVI units staring with serial number 1167 and later.

Revision: 2.4 Date: 121024

Approved by: JN

Before you start the process of disassembly of the mouthpiece, its IMPORTANT that you
establish what version of the mouthpiece it is that you are working on.

Item # Article #

Description

Qty

0005-054

Mouthpiece house assembly G2

0000-130

Hose adapter

6010-005

OC outlet

4532

Mouthpiece AIR

1167

Cable tie

1
Page 60

SERVICE MANUAL - Discovery MKVI

6. Mouthpiece G2
Mouthpiece: 0005-054 House assembly

Revision: 2.4 Date: 121024

Approved by: JN

Item # Article #

Description

Qty

0000-429

Mouthpiece house

0000-471

DV Switch

6010-013

Membrane holder complete

0000-427

Mouthpiece Lock Nut M45

0005-000

LP Valve Mk6

4536

Membrane cover Xstream

4533

Membrane with washer

0000-232

Membrane mouthpiece

2
Page 61

SERVICE MANUAL - Discovery MKVI

6. Mouthpiece G2
Mouthpiece: DV Switch (0000-471)

Description

Qty

6010-012

Barrel magnet

0000-293

Mouthpiece washer

6010-114

Helix Block

0015-245

O-ring

0010-120

O-ring

Revision: 2.4 Date: 121024

Approved by: JN

Item # Article #

Page 62

SERVICE MANUAL - Discovery MKVI

6. Mouthpiece G2
Mouthpiece: Low pressure valve MkVI (0005-000)

Revision: 2.4 Date: 121024

Approved by: JN

Item # Article #

Description

Qty

0000-148

Valve house nut

0011-278

O-ring

0012-016

O-ring

0013-001

O-ring

0013-009

O-ring

0013-351

O-ring

2787

Rubber plate

2857

Low pressure valve house

2875

Stop screw

10

3440

Valve insert

11

2839

Valve tube

12

2786

Servo valve

1
Page 63

SERVICE MANUAL - Discovery MKVI

6. Mouthpiece G2
Mouthpiece: Membrane holder complete (6010-013)

Description

Qty

0000-324

Membrane holder

0010-032

O-ring

0000-323

Membrane Check valve

Revision: 2.4 Date: 121024

Approved by: JN

Item # Article #

Page 64

SERVICE MANUAL - Discovery MKVI

6. Mouthpiece G2
Mouthpiece:
Disassembly
Parts
Remove the LP hose from the
hose adaptor.

Tools/Instructions

Picture

Remove the Diaphragm cover


(4536) from the mouth piece
housing.
Remove the membrane with
washer (4533) from the mouth
piece housing.
Remove the OC outlet (6010-005) Do not use force when
from the mouth piece housing.
removing the OC outlet.

Remove the hose adaptor from


mouth piece housing.
4

Revision: 2.4 Date: 121024

Approved by: JN

Unscrew the locking ring (0000427) and thread it out over the DV
switch.

Remove the DV Switch (0000471) from the mouth piece


housing by unscrewing the Lock
nut (0000-427). When the lock nut
is un-screwed, turn the DV switch
upwards until the DV switch points
towards the divers face.
Then pull the DV switch out.
Be carefull NOT to
damage o-ring 0015-245
on the barrel magnet! 6

Page 65

SERVICE MANUAL - Discovery MKVI

6. Mouthpiece G2
Mouthpiece:
Disassembly

Parts
Tools/Instructions
Unscrew the servo valve from the This is IMPORTANT!
valve tube.
If not removed, you risk
damaging the servo
valve.

Picture

Remove the O-ring (0015-245)


9

0010-120 O-ring
10

Remove the o-ring from


the barrel.

6010-114 Helix block


Unscrew the helix block
and then slide it off the
barrel.

11

0000-293 Plastic washer

Remove the plastic


washer from the barrel.

Revision: 2.4 Date: 121024

Approved by: JN

12

Remove the Low pressure valve


from the DV switch barrel.
13

14

Remove the stop screw (2875)


that holds the valve tube locked in
the valve house nut.

Page 66

SERVICE MANUAL - Discovery MKVI

6. Mouthpiece G2
Mouthpiece:
Disassembly
Parts
Unscrew the valve tube (2839)
from the valve house nut.

Tools/Instructions

Picture

15

16

Remove the 0013-001 O-ring from


the valve tube.

Remove the 0013-351 O-ring from


the valve tube.
17

18

18

Unscrew the valve house nut


(0000-148) from the low pressure
valve housing (2857).

Remove the rubber plate (2787)


that is located under the stop
screw (2875).

Revision: 2.4 Date: 121024

Approved by: JN

Remove the O-ring (0013-009)


20

Remove the O-ring (0012-016)


21

Page 67

SERVICE MANUAL - Discovery MKVI

6. Mouthpiece G2
Mouthpiece:
Disassembly

22

23

24

Parts
Remove the valve insert (3440)
from the low pressure valve
housing by pushing it out.

Tools/Instructions

Picture

Remove the o-ring (0011-278)


from the inside of the low pressure
valve housing.

Use a set of pliers to remove the


Membrane holder (6010-013).
Start with the exhale side.
Grab with the pliers and pull
gently.
Push the inhale side out.

25

Remove the o-ring (0010-032)


from the two membrane holders

Revision: 2.4 Date: 121024

Approved by: JN

26

Page 68

SERVICE MANUAL - Discovery MKVI

6. Mouthpiece G2
Mouthpiece:
Inspection
Parts
Servo valve (2786)

Inspect
Picture
Make sure that the tip is not
bent.

Valve tube (2839)

Check O-ring sealing


surfaces.

Valve insert (3440)

1. Ensure no circular cuts on


bladder surface.

2. Check O-ring sealing


surface.

0000-232 membrane

Approved by: JN
Revision: 2.4 Date: 121024

Replace if damaged.

0000-323 Membrane Check


valve

Make sure the check valves


arent damaged.

Replace if damaged.

4532 Mouthpiece AIR

Make sure the membrane


isnt damaged.

Check for damage and


holes.

replace if damaged.

Page 69

SERVICE MANUAL - Discovery MKVI

6. Mouthpiece G2
Mouthpiece:
Cleaning
If corrosion or salt deposits occurs on metallic parts, immerse part in concentrated Hempocid*
or 15% Hydrochloric acid for about 10 minutes or wash them in an ultra sonic washer.
Then rinse them thoroughly in fresh water and blow them dry with air. The synthetic parts must
not be treated with solvents and must only be cleaned with fresh water.
*Hempocid=Acid Liquid detergent containing phosphoric acid (5-10%) and bactericide for
disinfectant cleaning

Revision: 2.4 Date: 121024

Approved by: JN

Bag the parts below in a plastic bag for later assembly. These parts shall not be ultra
sonic cleaned but we recommend that you soak these parts in warm water and then rinsed in
fresh water.

4536 - Diaphragm
cover

4533 - Membrane
with washer

4532 - Mouthpiece

0000-323 - Membrane 0000-324 - Membrane


holder.
Check valve

6010-012 Barrel magnet

6010-005 - OC Outlet

0000-429 - Mouthpiece housing

0000-232 - Membrane
mouthpiece

0000-293 - Mouthpiece
washer
Page 70

SERVICE MANUAL - Discovery MKVI

6. Mouthpiece G2
Mouthpiece:
Assembly
Parts

Tools/Instructions

0011-278

Replace Picture

O-ring, viton

3440

Valve insert

Do not use lubricant on the


valve insert.
Only use soap and water.

0012-016 O-ring

0013-009 O-ring

0000-148

Vavle housing
nut

Revision: 2.4 Date: 121024

Approved by: JN

3 +/- 1 Nm

0013-351 O-ring

0013-001 O-ring
7

Page 71

SERVICE MANUAL - Discovery MKVI

6. Mouthpiece
Mouthpiece:
Assembly
Parts

Tools/Instructions

Replace Picture

2839 Valve tube


8

2787 Rubber plate

2875 Stop screw


10

0005-000 LP valve
11

6010-012 DV Switch

0000-293 Plastic washer

Thread the plastic washer


on to the barrel. Use the cut
in the washer to slide over
the knobs.

6010-114 Helix block

Thread the helix block on to


the barrel. Then screw it on
to the small knobs on the
barrel.

Approved by: JN

12

Revision: 2.4 Date: 121024

Insert the LP valve in to


the DV Switch. The locking
screw on the LP valv should
point in the oposite direction
of the DV Switch lever.

13

0010-120 O-ring

Thread the o-ring on to the


barrel.

14

Page 72

SERVICE MANUAL - Discovery MKVI

6. Mouthpiece
Mouthpiece:
Assembly
Parts

Tools/Instructions

0015-245 O-ring

Place the o-ring in the


groove. Apply a lot of
lubricant!

15

Replace Picture
R

4545 Servo valve


16
Push the assebled DV
The 0015-245 O-ring should
Switch and LP valve in to the be facing upwards and the
mouth piece housing.
DV Switch lever should be
17
pointing towards the divers
face.
When the assebled DV
Switch and LP valve is
pushed half way in to the
mouth piece housing, turn
18
the DV switch lever forward,
to OC position.
0000-427 Locking nut

Revision: 2.4 Date: 121024

Approved by: JN

19

Start attaching the DV switch


assembly to the mouth piece
housing by fastening the lock
20 nut.

21

The guiding pin on the helix


block, closest to the DV
Switch lever should align
with the groove marked No
1. When aligned, push the
DV switch assembly in to
position.
Thread the locking nut in to
the DV switch barrol, over
the DV switch.

As you turn the lock nut,


push the DV valve assembly
in to the mouth piece
housing.

When the lock nut has


grabbed on to the threads of
the mouthpice housing, turn
the DV switch to CC position
and make sure the lock nut
is tightned.
Page 73

SERVICE MANUAL - Discovery MKVI

6. Mouthpiece
Mouthpiece:
Assembly
Parts

Tools/Instructions

0000-130 Hose adapter

Attach the hose adpter to


the DV switch assembly.

6010-116 membrane holder


with membrane.

Start with the inhale


membrane. Push the
membraneholder in to the
mouthpiece housing. The
membrane should be on
the inside of the membrane
holder.

6010-116 membrane holder


with membrane.

Do the same with the exhale


membrane. Note that the
membrane should be on the
outside of the membrane
holder.

Replace Picture

22

23

24

Revision: 2.4 Date: 121024

Approved by: JN

4536 Diaphragm cover


4533 membrane with washer Push the membrane in to
the mouth piece housing.
25
Then snap on the diaphragm
cover.
6010-005 OC cover

Snap the OC cover back on


to the mouth piece housing.

6011-001 Mouthpiece

Assembly of the mouthpiece


is now complete.

26

27

Page 74

SERVICE MANUAL - Discovery MKVI

6. Mouthpiece
Mouthpiece:
Adjustment and final inspection

Action

Tools/Instructions

Attach the assembled


mouthpiece to a 1st stage
that is connected to a test
box.

Make sure the 1st stage


is set to an intermediate
pressure of 8,5 bar / 123,25
psi.

Set the mouth piece to Open If you look in to the mouth


Circuit (OC)
piece hole, you should see
the locking screw on the LP
valve insert.
Loosen the locking screw on Loosen the stop screw just
the LP valve housing nut.
enough to allow the valve
tube to move.

Adjust the cracking pressure By turning the valve tube


of the LP valve by turning the upwards, you move the
valve tube up or down.
servo valve closer to the
4533 membrane, lowering
the cracking pressure.

While still in OC mode.

Revision: 2.4 Date: 121024

Approved by: JN

Use the 2705 Adjustment


tool.
Adjust the valve tubing to a
position that you think will
give the desired cracking
pressure of 30 cm w.c.
Tighten the stop screw on
the LP valve houing nut.

Turn the DV switch over to


Closed Circuit (CC) mode.
6

Picture

While in CC mode:
Hold the mouthpiece-part of
the cracking pressure gauge
tight to the outlet of the
mouthpiece.
Block the inhalation
membrane opening.

Page 75

SERVICE MANUAL - Discovery MKVI

6. Mouthpiece
Mouthpiece:
Adjustment and final inspection

Action

Tools/Instructions

Take a few rather slow


and long inhalations from
the mouthpiece part and
simultaneously check the
pressure gauge needle.

It shall during inhalation


reach a level of 30 cm.w.c,
and at the end of the
inhalation decrease again.

Picture

The inhalation membrane


must be blocked during this
action.
If the reading is too high or
too low, turn the DV Switch
over to OC mode and
loosen the locking screw on
the valve housing nut.

Adjust the valve tube and


servo valve.
.
9

Screw the valve tube and


servo valve closer to the
diaphragm to lower the w.c.
To increase the w.c,
screw them away from the
diaphragm.

Revision: 2.4 Date: 121024

Approved by: JN

Repeat Action #7, #8 and


#9 untill the correct cracking Once 30 cm w.c has been
pressure of 30 cm w.c has
set, do a final test with
10 been set.
the locking screw firmly
tightened.

11

12

Cracking pressure in OC
mode.

The cracking pressure in OC


mode is not set but it should
be between 30 - 70 mm w.c.

Disconnect the mouthpiece


from the test box 1st stage.

Release the pressure


between the 1st stage and
moputhpiece and disconnect
the LP hose from the 1st
stage.
Adjustment is completed.

Page 76

SERVICE MANUAL - Discovery MKVI

8. Scrubber Canister Housing

Revision: 2.4 Date: 121024

Approved by: JN

6010-006 Round pack top

Item
1
2
3
4
5
6
7
8
9
11

Part No
6010-139
6010-265
0015-533
6010-192
6010-191
0014-013
0013-265
6010-129
0310-108
0010-402

Description
Top half
Top support
O-ring
CL_Interface
Diverter
O-ring
O-ring
Screw Delta PT20x8 WN5452
Screw Delta PT 40x8
O-ring

Nmbr
1
1
1
2
1
1
2
12
4
2
Page 77

SERVICE MANUAL - Discovery MKVI

8. Scrubber Canister Housing

Revision: 2.4 Date: 121024

Approved by: JN

0000-361 Round Pack Housing incl. helicoil

Item
1
2
3

Part No
6010-138
0310-134
6010-246

Description
Round Pack Housing
Screw MRT M6x40
Heli coil plus

Nmbr
1
6
4
Page 78

SERVICE MANUAL - Discovery MkVI

8. Scrubber Canister Housing

Revision: 2.0 Date: 100901

Approved by: JN

6011-011 Molprod Bottom

Item
1
2
3
4
5
6
7

Part No
6010-214
0014-293
6010-236
0310-108
6010-176
0015-533
6010-264

Description
Can bottom
O-ring
Sponge
Screw Delta PT 40x8
Screw foot
O-ring
Sponge washer

Nmbr
1
1
1
1
4
2
1

Page 79

SERVICE MANUAL - Discovery MkVI

8. Scrubber Canister Housing

Item
1
2
3

Part No
0014-292
6010-215
0014-293

Description
O-ring
Can top
O-ring

Nmbr
1
1
1

Revision: 2.0 Date: 100901

Approved by: JN

6011-012 Molprod Top

Page 80

SERVICE MANUAL - Discovery MkVI

8. Scrubber Canister Housing


6010-006 Round pack
Disassembly
Parts
6010-006 Round pack
6010-138 Round pack housing
1

0310-108 Screw x 2
6010-192 CL interface
0013-265 O-ring
2

0310-108 Screw x 2
6010-191 Diverter
0015-533 O-ring
0010-402 O-ring x 2
6010-191 Diverter
0014-013 O-ring

Picture

Unscrew the 6 screws


that attaches the Round
pack to the Round pack
housing.

Unscrew both 0310-108


screws.
Push the CL interface up
and inwards.
Remove o-ring 0013-265

Unscrew both 0310-108


screws.
Pull the Diverter out.
Remove o-ring 0015-533
Remove o-ring 0010-402

Remove O-ring 0014013 from the Diverter

Revision: 2.0 Date: 100901

Approved by: JN

Tools/Instructions

Page 81

SERVICE MANUAL - Discovery MkVI

8. Scrubber Canister Housing


6010-006 Round pack
Cleaning
After all o-rings have been removed, we recommend that all plastic round pack parts are placed
in a container with a mix of warm water and dish washing deturgent and that the parts are left
there to soak for 15 - 20 minutes. This will be enough to disolve most dirt and grease from the
parts.
All screws should be placed in a 10% acid solution for aprox. 10 minutes or washed in an ultra
sonic cleaner.
After the soak, let the parts air dry until they are completly dry.

8. Scrubber Canister Housing


6010-006 Round pack
Inspection
Parts
6010-138 Round pack housing
- Threads

6010-265 Top support


6010-192 CL Interface x 2
6010-139 Top half
6010-191 Diverter

Check all parts and threads for


damages.

6010-129 Screw x 12
0310-108 Screw x 4
3

Check all threads for damage

Revision: 2.0 Date: 100901

Approved by: JN

Picture

Check the six threads, used to


attach the round pack to the
housing, for damage.

Tools/Instructions

Page 82

SERVICE MANUAL - Discovery MkVI

8. Scrubber Canister Housing


6010-006 Round pack
Assembly
Parts
0014-013 O-ring
6010-191 Diverter
1

Tools/Instructions

Picture
R

Mount o-ring

0010-402 O-ring x 2
6010-191 Diverter
2

R
Mount o-rings

0015-533 O-ring
6010-191 Diverter
0310-108 Screws PT 40 x 2
6010-138 Top half
3

Place the 0015-533


o-ring between the
Diverter and top half.
Mount the Diverter on
to the top half with two
screws.

Max Torque: 1,23 Nm

0013-265 O-ring
6010-192 CL Interface
Place the o-ring on
the groove on the CL
interface.

Revision: 2.0 Date: 100901

Approved by: JN

6010-192 CL Interface
6010-139 Top half
0310-108 Screw PT 40 x 2
5

Place the CL interface in


designated place on the
Top Half. Attach the CL
interface with the screw.
Max Torque: 1,23 Nm

Page 83

SERVICE MANUAL - Discovery MkVI

8. Scrubber Canister Housing


6010-138 Round Pack housing
Disassembly
We recommend you only do this step if there is something wrong with the tank band(s) or if there is damage to the grooves
where the bumpers are attached.

Parts
0310-134 Screw x 6

Tools/Instructions

Picture

Make sure all six (6)


screws are removed.

6010-242 Bumper
2

0000-016 Tank belt x 4


3

Remove the bumbers by


pulling them upwards,
along the houing untill
they come loose
Remove the tank belts
by pulling them upwards,
along the groove they
are slid in to, until they
come off.

6010-246 Heli coils x 4


Do not remove the heli
coils from the housing.

Revision: 2.0 Date: 100901

Approved by: JN

Page 84

SERVICE MANUAL - Discovery MkVI

8. Scrubber Canister Housing


6010-138 Round pack housing
Cleaning
We recommend that the round pack housing is placed in a container with a mix of warm water
and dish washing deturgent and that the part is left there to soak for 15 - 20 minutes. This will
be enough to disolve most dirt and grease from the part.
After the soak, let the part air dry until it is compleatly dry.

8. Scrubber Canister Housing


6010-138 Round pack housing
Inspection
Parts
6010-138 Round pack housing

Lubricate the threads.


Apply some loctite 8023
anti corrosion paste on
the heli coils.

6010-138 Round pack housing

Approved by: JN

Picture

Inspect heli coil inserts


for signs of damage.
Lubricate the threads.
Apply some loctite 8023
anti corrosion paste on
the heli coils.

Revision: 2.0 Date: 100901

Tools/Instructions
Inspect threads for signs
of damage.

6010-138 Round pack housing

Inspect the whole


housing for signs
of damage and/or
corrosion.

Page 85

SERVICE MANUAL - Discovery MkVI

8. Scrubber Canister Housing


6011-011 Molprod bottom
Disassembly
Parts
6010-236 Sponge
1

Tools/Instructions

Picture

Remove the sponge.

0014-293 O-ring
0015-533 O-ring x 2
2

Remove the o-rings

6010-176 Screw, foot


6010-214 Can bottom
3

Do not remove the


screws from the can
bottom

8. Scrubber Canister Housing


6011-011 Molprod bottom
Cleaning

After the soak, let the parts air dry until they are compleatly dry.

Revision: 2.0 Date: 100901

Approved by: JN

We recommend that all parts of the Molprod bottom are placed in a container with a mix of
warm water and dish washing deturgent and that the parts are left there to soak for 15 - 20
minutes. This will be enough to disolve most dirt and grease from the parts.

Page 86

SERVICE MANUAL - Discovery MkVI

8. Scrubber Canister Housing


6011-011 Molprod bottom
Assembly
Parts
6010-236 Sponge
1

0014-293 O-ring
0015-533 O-ring x 2
2

Tools/Instructions
Place the new sponge
in the centre of the Can
bottom.

Picture

Mount the o-rings on the


Can bottom.

8. Scrubber Canister Housing


6011-012 Molprod top

Parts
0014-292 O-ring
0014-293 O-ring
1

Tools/Instructions

Picture

Remove the o-rings

Revision: 2.0 Date: 100901

Approved by: JN

Disassembly

Page 87

SERVICE MANUAL - Discovery MkVI

8. Scrubber Canister Housing


6011-011 Molprod Top
Cleaning
We recommend that the Molprod top is placed in a container with a mix of warm water and dish
washing deturgent and that the part is left there to soak for 15 - 20 minutes. This will be enough
to disolve most dirt and grease from the part.
After the soak, let the part air dry until it is compleatly dry.

8. Scrubber Canister Housing


6011-012 Molprod top
Assembly
Parts
0014-292 O-ring
0014-293 O-ring

Picture
R

Mount the o-rings on the


Molprod top.

Revision: 2.0 Date: 100901

Approved by: JN

Tools/Instructions

Page 88

SERVICE MANUAL - Discovery MKVI

9. Breathing loop

Revision: 2.4 Date: 121024

Approved by: JN

Breathing loop components: 6010-020 Right counter lung

Item
1
2
3
4
5
6
7
8

Part No
6010-008
6010-011
6010-018
6010-133
6010-277
0000-180
0013-187
0000-182

Description
Lung shell right
T-Section
Innerbladder right
T-Lunginsert
Ring nut valve insert
Automatic outlet valve
O-ring
Valve patch Flexisuit

Nmbr
1
1
1
1
1
1
2
1

Page 89

SERVICE MANUAL - Discovery MKVI

7. Breathing loop

Revision: 2.4 Date: 121024

Approved by: JN

Breathing loop components: 6010-021 Left counter lung

Item
1
2
3
4
5
6
7

Part No
6010-009
6010-011
6010-019
6010-133
6010-273
6010-277
0013-187

Description
Lung shell left
T-Section
Innerbladder left
T-Lunginsert
Blind insert
Ring nut valve insert
O-ring

Nmbr
1
1
1
1
1
2
4

Page 90

SERVICE MANUAL - Discovery MKVI

7. Breathing loop

Revision: 2.4 Date: 121024

Approved by: JN

Breathing loop components: 6010-011 T-section

Item
1
2
3
4

Part No
6010-131
6010-130
0010-140
0013-261

Description
T-top
T-Bone
O-ring
O-ring

Nmbr
1
1
1
1

Page 91

SERVICE MANUAL - Discovery MKVI

7. Breathing loop
Breathing loop components: 0132-003 CC hose (x 4)

Description
CC hose
O-ring

Nmbr
1
2

Revision: 2.4 Date: 121024

Approved by: JN

Item Part No
1
0132-003
2
0013-261

NOTE: The CC hoses connections can not be disassembled.


Page 92

SERVICE MANUAL - Discovery MKVI

7. Breathing loop
Breathing loop components: Counter lungs
Disassembly
Parts
6010-277 Ring nut valve insert

Tools/Instructions
Unscrew the Ring nut
valve insert from the
inner bladder threads

6010-133 T-lung insert


6010-273 Blind insert

Pull out the T-lung


inserts and Blind insert
from the inner bladder
threads.

0000-180 Automatic outlet valve

Un-screw the automatic


outlet valve from the
right side (exhale)
counter lung.

Picture

6010-008 Lung shell right


6010-009 Lung shell left
6010-018 Inner bladder right
6010-019 Inner bladder left

Open the zipper on the


lung shell and take out
the inner bladders.6

7. Breathing loop

Revision: 2.4 Date: 121024

Approved by: JN

Breathing loop components: T-section


Disassembly
Parts
6010-131 T-top

Tools/Instructions

Picture

Unscrew the T-top from


the T-section

Page 93

SERVICE MANUAL - Discovery MKVI

7. Breathing loop
Breathing loop components:
Cleaning
All o-rings that are attached to any parts of the breathing loop should be removed, using the
o-ring remover.
It is recommended that when servicing the Discovery MkVI rebreather, all breathing loop
components should be disinfected.

Revision: 2.4 Date: 121024

Approved by: JN

- We recommend that you use a disinfection liquid by the name of Gigasept.


- Follow all the safety instructions on the bottle/box.
- Mix a 5% Gigasept solution (5% Gigasept, 95% water) in a suitable container.
- Lower the CC hoses, T-connections and all other plastic parts in the solution.
- Lower the inner bladders in the solution and let them fill up with the liquid.
- Let all parts soak in the solution for 40 minutes.
- When the parts are done soaking, wash them in clean water.

Page 94

SERVICE MANUAL - Discovery MKVI

7. Breathing loop
Breathing loop components: CC hoses, counter lungs and T-sections
Inspection
Parts
6010-277 Ring nut valve insert

Tools/Instructions

Picture

Make sure the part is intact and


without damage.

6010-273 Blind insert


Make sure the part is intact and
without damage.

0000-180 Automatic outlet valve


Make sure the valve isnt
damaged and that it can turn
without any problems.

6010-008 Lung shell right


6010-009 Lung shell left
6010-018 Inner bladder right
6010-019 Inner bladder left

Check the lung shells for damage


and/or holes.
Check inner bladders for holes
or damage, and make sure the
connection threads are intact.6

6010-130 T-bone
6010-131 T-top
Check the housing, top and the
threads for damage.
6010-270 CC hose
6

Make sure the CC hoses arent


damaged and that there are no
holes in them.

Revision: 2.4 Date: 121024

Approved by: JN

Page 95

SERVICE MANUAL - Discovery MKVI

7. Breathing loop
Breathing loop components: CC hoses
Assembly
Parts
6010-270 CC hose
0013-261 O-ring

Replace the O-rings

Picture
R

Revision: 2.4 Date: 121024

Approved by: JN

Tools/Instructions

Page 96

SERVICE MANUAL - Discovery MKVI

7. Breathing loop
Breathing loop components: T-sections
Assembly
Parts
6010-130 T-bone
0013-261 O-ring
1

Tools/Instructions

Replace o-ring

Replace o-ring

6010-131 T-top
0010-140 O-ring
2

Picture

6010-131 T-top
6010-130 T-bone

Assemble the T-top and


the T-bone. Be careful
with the threads.

6010-011 T-section
Repeat step 1 - 3 on the
second T-section.

Revision: 2.4 Date: 121024

Approved by: JN

Page 97

SERVICE MANUAL - Discovery MKVI

7. Breathing loop
Breathing loop components: Counter lungs
Assembly

Parts
6010-008 Lung shell right
6010-009 Lung shell left
6010-018 Inner bladder right
6010-019 Inner bladder left

6010-133 T-lung insert x 2


0013-187 O-rings x 6
0610-273 Blind insert x 1

3
0610-273 Blind insert x 1
4
6010-277 Ring nut valve insert x 3
5
0000-182 Valve patch
0000-180 Autom. outlet valve

Approved by: JN

Picture

Insert the inner bladder


in to the outer bladder.
Align the inner bladder
male threads with the
(The inner bladder right, is the one top end hole of the outer
with white female threads)
bladder.

6010-133 T-lung insert x 2

Revision: 2.4 Date: 121024

Tools/Instructions

R
Replace the o-rings

Mount the T-lung insert


with o-rings attached in
the top thread on each
lung.
Mount the blind insert
with o-rings attached in
the bottom thread on the
left side lung
Mount the Ring nut valve
inserts on each male
thread on both lungs.
Mount the Autom. outlet
valve and valve patch on
the lower female thread
of the right side lung.
Make sure the fabric of
the outer lung is properly
aligned to avoid leaks.

6010-011 T-section x 2
7

Mount the T-sections,


one on each counter
lung.
Make sure the water trap
is mounted correctly!

Page 98

SERVICE MANUAL - Discovery MKVI

10. Electronics module and battery


6010-039 O2 sensor base Cpl. & 6010-047 Electronics module

Revision: 2.4 Date: 121024

Approved by: JN

Item
10
11
12

Part No
6010-205
0013-215
0013-214

Description
O2 sensor base
O-ring
O-ring

Item
1
2
3
4
5
6
7
8
9

Part No
6010-036
6010-039
0015-467
0015-461
6011-005
6011-004
6010-044
6010-045
6010-014

Nmbr
1
1
1

Description
Electronics module
2 sensor base compl.
O-ring
O-ring
Battery pack
To the Display
To the HP sensor w. banjo Dil
To the HP sensor w. banjo O2
To the HUD

Nmbr
1
2
1
1
1
1
1
1
1
Page 99

SERVICE MANUAL - Discovery MKVI

9. Electronics module and battery

Revision: 2.4 Date: 121024

Approved by: JN

6011-005 Battery pack and 6011-015 Battery charger

Item
1
2
3

Part No
6011-005
6011-015
0013-038

Description
Battery pack
Battery charger
O-ring

Nmbr
1
1
1

Page 100

SERVICE MANUAL - Discovery MKVI

9. Electronics module and battery


0005-006 Banjo 90 HP O2 and 3291 Banjo 90 HP

Revision: 2.4 Date: 121024

Approved by: JN

0005-006
Item
1
2a
2b
3
4
5a
5b
6

Part No
3292
0011-276
0010-353
3293
3294
0011-277
0010-354
1095

3291
Description
Banjo screw
O-ring Viton (2782 59)
O-ring
Banjo house
Spacer
O-ring Viton (2918 59)
O-ring (2918)
Strangle screw

Nmbr
1
2
2
1
1
1
1
1

Page 101

SERVICE MANUAL - Discovery MKVI

9. Electronics module and battery


6010-047 Electronics module
Disassembly
Parts
6011-005 Battery pack
1

Tools/Instructions

Picture

The battery pack should


have been removed
from the electronics
unit before the service
began.

0015-461 O-ring
0015-467 O-ring
2

Remove the o-rings

0013-214 O-ring
0013-215 O-ring
3

Remove the o-rings

9. Electronics module and battery


6010-047 Electronics module
Cleaning
Do NOT submerge/soak the whole electronics module in any liquid!
Doing that might cause damage to the electronics.

Revision: 2.4 Date: 121024

Approved by: JN

Use a damp cloth to clean the electronics module up, if needed.


The only two parts of the electronics module that may be submerged/soaked in liquid is the
display unit and the HUD.

9. Electronics module and battery


6010-047 Electronics module
Inspection
Parts
6010-047 Electronics module
1

Tools/Instructions

Picture

Check the Electronics


module for damage

Page 102

SERVICE MANUAL - Discovery MKVI

9. Electronics module and battery


6010-047 Electronics module
Inspection
Parts
6010-047 Electronics module
2

Tools/Instructions

Picture

Check the hoses/wires


to the HP sensors, the
HP sensors, HUD and
primary display for holes
and/or damage.

6010-047 Electronics module


Check the Primary
display and HUD for
damages.

6010-047 Electronics module

If any part of the


electronics module is
damaged, the whole
module needs to be sent
to the local Distributor.
Do NOT attempt to
repair the module!

6010-047 Electronics module

Check:
- Cables to the O2
sensors.
- O2 sensor connections.
- Battery connections.

Revision: 2.4 Date: 121024

Approved by: JN

9. Electronics module and battery


6010-047 Electronics module
Assembly
Parts
0015-461 O-ring
0015-467 O-ring
1

Tools/Instructions

Mount the o-rings

Picture

Page 103

SERVICE MANUAL - Discovery MKVI


0013-214 O-ring
0015-215 O-ring
2

Mount the o-rings

9. Electronics module and battery


0005-006 Banjo 90 HP O2
Disassembly
Do not disassemble the O2 Banjo connection in the clean room environment. All parts
shall be taken to the clean room environment after inspection and after the pre-cleaning
process if such is needed. Otherwise you risk to contaminate the clean room environment.
New parts should be stored in its original packing until it is time for assembly.
To remove o-rings, ONLY use o-ring remover tool 2297. Make sure not to damage
o-ring and sealing surfaces!!
Parts
0011-277 O-ring (2918 59)
1

Tools/Instructions

Picture

Remove the o-ring

3294 Spacer

Revision: 2.4 Date: 121024

Approved by: JN

Remove the spacer

3293 Banjo house


3

Remove the banjo house

0011-276 O-ring (2782 59) x 2


4

Remove the o-rings

Page 104

SERVICE MANUAL - Discovery MKVI

9. Electronics module and battery


0005-006 Banjo 90 HP O2
Cleaning
Make absolutely sure Hydrochloric acid is NOT poured into the ultra-sonic cleaner. It
would then destroy the ultra-sonic cleaner and the parts attempted to be cleaned.
If corrosion or salt deposits occurs on metallic parts, immerse part in concentrated Hempocid*
or 15% Hydrochloric acid for about 10 minutes. Then rinse them thoroughly in fresh water and
blow them dry with air. The synthetic parts must not be treated with solvents and must only be
cleaned with fresh water.
*Hempocid=Acid Liquid detergent containing phosphoric acid (5-10%) and bactericide for
disinfectant cleaning
Cleaning for Oxygen Use
The process of cleaning for oxygen use and the information given herein shall be strictly adhered
to. Only then can Poseidon guarantee the part will be cleaned to a cleanliness level which is
acceptable for its intended use. This process has been verified to produce hydrocarbon residual
levels less than 50mg/m2 and a particulate level less than Cleaning Test Level 100 (ASTM G 93
Spec.)
As an alternative, oxygen servicing procedures can be carried out in accordance with other
herein listed organizations standard procedures and requirements. However, the use of
cleaning agents, the order of the operating sequences and the time to treat parts during ultra
sonic cleaning as specified in this manual must be adhered to. Wherever there is a conflict
between the procedures and set of requirements, unless the other procedure represents a
greater requirement for cleanliness, this manual takes precedence. Some methods, equipment,
and detergents which are not mentioned in this manual can have a harmful or unknown effect
on materials, such as e.g. ozone cleaning systems, strong acids etc. and shall therefore be
discarded.
The other standard procedures that can be used given the limitations above are:
EAN and Oxygen Servicing Procedures, Fourth Edition (ANDI)
IANTD Gas Blender & Service Technician Program, First Edition, August 1999
MIL-STD-1330D (SH) of the 20 September 1996
The safety of your customer and yourself depends on you carefully and strictly following these instructions. Negligence in
any step can cause serious injury or even death.

Keep hands and tools clean and free from grease, except for what is required and stated in this manual. We recommend
that you use lint-free gloves when handling parts used with O2.

Revision: 2.4 Date: 121024

Approved by: JN

You must be certified by Poseidon as oxygen technician to undertake this procedure.

Page 105

SERVICE MANUAL - Discovery MKVI

9. Electronics module and battery


0005-006 Banjo 90 HP O2
Assembly
Use protective clothing to prevent dust, fingerprints, hair, and particles to contaminate.
Use only dedicated and cleaned tools.
Ensure your oxygen handling is in conjunction with national laws.
Ensure no foreign contaminants, such as e.g. liquids, grease, particulate, dust, and mist can enter into the cleanroom
area.

Parts
0011-276 O-ring (2782 59) x 2

Tools/Instructions

Mount the o-rings

Picture

3293 Banjo house


Thread the Banjo house
on to the Banjo screw,
over the o-rings.

3294 Spacer
3

Mount the spacer

Mount the o-rings

Revision: 2.4 Date: 121024

Approved by: JN

0011-277 O-ring (2918 59)

Page 106

SERVICE MANUAL - Discovery MKVI

9. Electronics module and battery


3291 Banjo 90 HP
Disassembly
To remove o-rings, ONLY use o-ring remover tool 2297. Make sure not to damage
o-ring and sealing surfaces!!
Parts
0011-277 O-ring (2918)
1

Tools/Instructions

Picture

Remove the o-ring

3294 Spacer
2

Remove the spacer

3293 Banjo house


3

Remove the banjo house

0010-353 O-ring (2782) x 2

Revision: 2.4 Date: 121024

Approved by: JN

Remove the o-rings

9. Electronics module and battery


3291 Banjo 90 HP
Cleaning
The metal parts of the 3291 Banjo connection can be cleaned using an ultra sonic washer or
placed in a 10% acid solution bat for 10 minutes.
Air dry the parts after cleaning.

Page 107

SERVICE MANUAL - Discovery MKVI

9. Electronics module and battery


0000-160 Banjo 90 HP
Assembly
Parts
0010-353 O-ring (2782) x 2

Tools/Instructions

Mount the o-rings

Picture

3293 Banjo house


Thread the Banjo house
on to the Banjo screw,
over the o-rings.

3294 Spacer
3

Mount the spacer

0011-277 O-ring (2918)

Mount the o-rings

Revision: 2.4 Date: 121024

Approved by: JN

Page 108

SERVICE MANUAL - Discovery MKVI

9. Electronics module and battery


6011-005 Battery pack with 6011-015 Charger
Inspection
Parts
6011-005 Battery pack

Tools/Instructions

Picture

Check the battery


pack for damage. If its
damaged, it needs to be
replaced.

6011-005 Battery pack


0013-038 O-ring

R
Remove and replace the
O-ring

6011-005 Battery pack


6011-015 Battery Charger
3

6011-005 Battery pack


6011-015 Battery Charger

Make sure that the


battery is charging
and that the charger is
working according to
instructions.

6011-005 Battery pack


6011-015 Battery Charger
4

Allow the battery to be


fully charged.

Revision: 2.4 Date: 121024

Approved by: JN

Connect the battery


charger to a power
outlet.
Place the battery in the
charger.

Page 109

SERVICE MANUAL - Discovery MKVI

11. Valves

Revision: 2.3 Date: 121024

Approved by: JN

0410-100 Diluent valve - 200 bar

Item
1
2
3
4
5
6
7
8
9
10
11
12
13

Part No
6010-263
2572
3063
2569
1037
1002
2597
0010-006
0012-028
0015-627
1006
4414
4416-BK

Description
Tank valve housing
Valve spindle
Water protection pipe
Sealing nut
Valve cone
Spring nut
Washer
O-ring
O-ring
O-ring
Gasket
Spring
Tank handle

Nmbr
1
1
1
1
1
1
1
1
1
1
1
1
1
Page 110

SERVICE MANUAL - Discovery MKVI

10. Valves

Revision: 2.3 Date: 121024

Approved by: JN

0410-101 Oxygen valve - 200 bar

Item
1
2
3
4
5
6
7
8
9
10
11
12
13

Part No
6010-263
2572
3063
2569
1037
1002
2597
0011-003
0011-037
0016-382
1006
4414
4416-WE

Description
Tank valve housing
Valve spindle
Water protection pipe
Sealing nut
Valve cone
Spring nut
Washer
O-ring viton
O-ring viton
O-ring viton
Gasket
Spring
Tank handle

Nmbr
1
1
1
1
1
1
1
1
1
1
1
1
1
Page 111

SERVICE MANUAL - Discovery MKVI

10. Valves
0410-100 Diluent valve - 200 bar and 0410-101 Oxygen valve - 200 bar
The service instructions described in this section ONLY apply to the Poseidon valves, with
article number 0410-100 and 0410-101, that are delivered with the Discovery MkVI EU version.
These valves do not contain any busr disc, and can not be used in the USA or any other country
where a burst disc in the valve is required.

10. valves
0410-101 Oxygen valve - 200 bar
Disassembly
Do not disassemble the O2 valve in the clean room environment. All parts shall be
taken to the clean room environment after inspection and after the pre-cleaning process
if such is needed. Otherwise you risk to contaminate the clean room environment. New
parts should be stored in its original packing until it is time for assembly.
To remove o-rings, ONLY use o-ring remover tool 2297. Make sure not to damage
o-ring and sealing surfaces!!
The valves should be removed from the tank(s) before the servicing process starts.
DO NOT service the valves while they are connected to the tank(s)!!

Parts
0410-101 oxygen valve

Approved by: JN

Picture

Unscrew the valve from


the oxygen tank.

Revision: 2.3 Date: 121024

Tools/Instructions

1002 Spring nut


Unscrew the spring
nut with a 6 mm allen
wrench.

4414 Spring
3

Remove the spring

Page 112

SERVICE MANUAL - Discovery MKVI

10. valves
0410-101 Oxygen valve - 200 bar
Disassembly
Parts
4416-we Tank handle
2597 Washer
4

Tools/Instructions

Picture

Remove the tank handle


and the washer

0011-003 O-ring
5

Remove the o-ring

2569 Sealing nut


6

2572 Valve spindel


1006 gasket
7

Place the valve in a


fixture/vice.
Remove the sealing nut
with a 19 key.

Pull the valve spindle out


from the sealing nut and
remove the gasket.

0011-037 O-ring Viton

Revision: 2.3 Date: 121024

Approved by: JN

Remove the o-ring.

1037 Valve cone


Use a screwdriver to
unscrew the Valve cone.

0016-382 O-ring
10

Remove the O-ring

Page 113

SERVICE MANUAL - Discovery MKVI

10. Valves
0410-101 Oxygen valve - 200 bar
Cleaning
Make absolutely sure Hydrochloric acid is NOT poured into the ultra-sonic cleaner. It
would then destroy the ultra-sonic cleaner and the parts attempted to be cleaned.
If corrosion or salt deposits occurs on metallic parts, immerse part in concentrated Hempocid*
or 15% Hydrochloric acid for about 10 minutes. Then rinse them thoroughly in fresh water and
blow them dry with air. The synthetic parts must not be treated with solvents and must only be
cleaned with fresh water.
*Hempocid=Acid Liquid detergent containing phosphoric acid (5-10%) and bactericide for
disinfectant cleaning
Cleaning for Oxygen Use
The process of cleaning for oxygen use and the information given herein shall be strictly adhered
to. Only then can Poseidon guarantee the part will be cleaned to a cleanliness level which is
acceptable for its intended use. This process has been verified to produce hydrocarbon residual
levels less than 50mg/m2 and a particulate level less than Cleaning Test Level 100 (ASTM G 93
Spec.)
As an alternative, oxygen servicing procedures can be carried out in accordance with other
herein listed organizations standard procedures and requirements. However, the use of
cleaning agents, the order of the operating sequences and the time to treat parts during ultra
sonic cleaning as specified in this manual must be adhered to. Wherever there is a conflict
between the procedures and set of requirements, unless the other procedure represents a
greater requirement for cleanliness, this manual takes precedence. Some methods, equipment,
and detergents which are not mentioned in this manual can have a harmful or unknown effect
on materials, such as e.g. ozone cleaning systems, strong acids etc. and shall therefore be
discarded.
The other standard procedures that can be used given the limitations above are:
EAN and Oxygen Servicing Procedures, Fourth Edition (ANDI)
IANTD Gas Blender & Service Technician Program, First Edition, August 1999
MIL-STD-1330D (SH) of the 20 September 1996
The safety of your customer and yourself depends on you carefully and strictly following these instructions. Negligence in
any step can cause serious injury or even death.

Revision: 2.3 Date: 121024

Approved by: JN

You must be certified by Poseidon as oxygen technician to undertake this procedure.


Keep hands and tools clean and free from grease, except for what is required and stated in this manual. We recommend
that you use lint-free gloves when handling parts used with O2.
When the Oxygen valve is removed, the oxygen tank shoudl be cleaned in accordence with industry standard cleaning
instructions and procedures.

10. Valves
0410-101 Oxygen valve - 200 bar
Inspection
Check all parts for signs of damage.
Scratch marks on critical parts may cause the valve to leak.
Page 114

SERVICE MANUAL - Discovery MKVI

10. valves
0410-101 Oxygen valve - 200 bar
Assembly
Parts
1037 valve cone
1

Tools/Instructions
Apply some oxygen
grease #1 to the threads
of the valve cone.

Picture

1037 Valve cone


Screw the valve cone all
the way to the bottom of
the valve housing.

0011-003 O-ring
3

Thread the o-ring on to


the valve spindle.
2572 Valve spindel
1006 gasket

Thread the gasket on to


the valve spindle.

Revision: 2.3 Date: 121024

Approved by: JN

2572 Valve spindle


2569 Sealing nut
0011-037 O-ring

2569 Sealing nut


2572 Valve spindle
6

2569 Sealing nut


7

Thread the sealing nut


over the Valve spindle.
Mount the o-ring on the
sealing nut.

Place the valve spindle


in the valve housing, so
that the flat end fits into
the groove on the valve
cone.
Screw the Sealing nut
in to the valve housing,
using a torque wrench.
Torque: 30 N

Page 115

SERVICE MANUAL - Discovery MKVI

10. valves
0410-101 Oxygen valve - 200 bar
Assembly
Parts
2579 Washer
4416-WE Tank handle
8

Tools/Instructions

Picture

Thread the washer and


tank handle on to the
Sealing nut.

4416-WE Tank handle


Unscrew the tank handle
counter clock wise untill
it stops.

4414 Spring
Place the spring in the
hole on the top of the
Tank handle.

10

1002 Spring nut


Attach the spring nut
with a 6 mm Allen key.
Tighten with hand force.

11

10. valves
0410-100 Valve - 200 bar
Disassembly

Revision: 2.3 Date: 121024

Approved by: JN

Parts
0410-100 Valve
1

Tools/Instructions

Picture

Unscrew the valve from


the diluent tank.

1002 Spring nut


Unscrew the spring
nut with a 6 mm allen
wrench.

4414 Spring
3

Remove the spring

Page 116

SERVICE MANUAL - Discovery MKVI

10. valves
0410-101 Oxygen valve - 200 bar
Disassembly
Parts
4416-we Tank handle
2597 Washer
4

Tools/Instructions

Picture

Remove the tank handle


and the washer

0010-006 O-ring
5

Remove the o-ring

2569 Sealing nut


6

2572 Valve spindel


1006 gasket
7

Place the valve in a


fixture/vice.
Remove the sealing nut
with a 19 key.

Pull the valve spindle out


from the sealing nut and
remove the gasket.

0012-028 O-ring
8

Remove the o-ring.

Revision: 2.3 Date: 121024

Approved by: JN

1037 Valve cone


Use a screwdriver to
unscrew the Valve cone.

0015-627 O-ring
10

Remove the O-ring

Page 117

SERVICE MANUAL - Discovery MKVI

10. Valves
0410-100 Valve - 200 bar
Cleaning
All metal parts of the valve can either be washed in an ultra sonic washer or submerged in a
container with a 10% acid solution for 10 - 15 minutes.
Rinse all parts in water after the wash.
Let the parts air dry.

10. Valves
0410-100 Valve - 200 bar
Inspection
Check all parts for signs of damage.

Revision: 2.3 Date: 121024

Approved by: JN

Scratch marks on critical parts may cause the valve to leak.

Page 118

SERVICE MANUAL - Discovery MKVI

10. valves
0410-100 Valve - 200 bar
Assembly
Parts
1037 valve cone
1

Tools/Instructions
Apply some regulator
grease to the threads of
the valve cone.

Picture

1037 Valve cone


Screw the valve cone all
the way to the bottom of
the valve housing.

0010-006 O-ring

R
Thread the o-ring on to
the valve spindle.

2572 Valve spindel


1006 gasket

Thread the gasket on to


the valve spindle.

Revision: 2.3 Date: 121024

Approved by: JN

2572 Valve spindle


2569 Sealing nut
0011-037 O-ring

2569 Sealing nut


2572 Valve spindle
6

2569 Sealing nut


7

Thread the sealing nut


over the Valve spindle.
Mount the o-ring on the
sealing nut.

Place the valve spindle


in the valve housing, so
that the flat end fits into
the groove on the valve
cone.
Screw the Sealing nut
in to the valve housing,
using a torque wrench.
Torque: 30 N
Page 119

SERVICE MANUAL - Discovery MKVI

10. valves
0410-100 Valve - 200 bar
Assembly
Parts
2579 Washer
4416-WE Tank handle

Tools/Instructions

Picture

Thread the washer and


tank handle on to the
Sealing nut.

4416-WE Tank handle


9

Unscrew the tank handle


counter clock wise untill
it stops.

4414 Spring
Place the spring in the
hole on the top of the
Tank handle.

10

1002 Spring nut


11

Attach the spring nut


with a 6 mm Allen key.
Tighten with hand force.

10. valves

Revision: 2.3 Date: 121024

Approved by: JN

0410-100 Valve 200 bar and 0410-101 Oxygen valve - 200 bar
Mounting on tanks
When mounting the valve(s) on to the the tank(s), they should be tightend using a torque wrench.
Torque forces:
Mounting on an aluminum tank: 90 +/- 10 Nm
Mounting on an steel tank: 90 +/- 10 Nm
If a lubricat is applied to the valve threads prior to mounting the valve on a tank, make sure that a oxygen approved
lubricant is used before mounting the oxygen valve on an oxygen clean tank!

The safety of your customer and yourself depends on you carefully and strictly following these instructions. Negligence in
any step can cause serious injury or even death.

Page 120

SERVICE MANUAL - Discovery MKVI

12. Final assembly

Revision: 2.4 Date: 121024

Approved by: JN

6011-000 MkVI Discovery EU, 6011-020 Mk VI Discovery US

Item
1
2
3
4
5
6
7
8
9
10
11
12
12
13
14
14
15
16
17
18

Part No
6011-003
6010-047
0132-003
0000-116
6010-011
0400-100
0400-101
6010-021
6010-020
0410-101
0410-100
0110-002
0110-003
0110-000
6011-001
0005-055
0100-006
0130-004
0130-017
0130-018

Description
Roundpack
Electronics module
CC Hose compl.
Tank band Discovery MkVI
T-section
3L 200 bar tank DIL (EU)
3L 200 bar tank O2 (EU)
Counter lung left
Counter lung right
Tank valve O2 (EU)
Tank valve DIL (EU)
Xstream Oxy M26 (EU)
Xstream Duration G5/8 (US)
Xstream Deep
Mouthpiece
Mouthpiece G2
Jetstream Octopus Mk3
LP Hose 90 cm
LP hose DIL 16 cm
LP hose O2 16 cm

Nmbr
1
1
4
4
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Page 121

SERVICE MANUAL - Discovery MKVI

11. Final assembly


This chapter describes the steps to assemble and prepare the MkVI Discovery for after service
testing.
Assembly

Parts
6010-138 Round pack housing
0000-160 Tank band
6010-242 Bumper

6010-138 Round pack housing


6010-006 Round pack
2

6010-138 Round pack housing


6011-011 Molprod bottom
3

Tools/Instructions

Picture

Mount the tank bands on


the sides of the round pack
housing. Push the bumpers
in to place on the round pack
housing.
Mount the Round pack on the
top of the round pack housing
and secure it with the six
screws.
Mount the molprod bottom on
the bottom end of the round
pack housing. Secure with the
four screws.

6010-047 Electronics module


Mount the electronics module
on to the round pack and
secure it with the two screws.

Revision: 2.4 Date: 121024

Approved by: JN

0410-100 Tank valve DIL


0400-100 3L Alum. tank, 200 bar
ONLY EU

0410-101 Tank valve O2


0400-100 3L Alum. tank, 200 bar
ONLY EU

6010-016 CC hose compl. x 2


6010-006 Round pack
7

Mount the DIL (black) tank


valve on to the DIL tank.

Mount the O2 tank valve on to


the O2 tank.

Mount one CC loop hose on


each CL Interface on the round
pack.

Page 122

SERVICE MANUAL - Discovery MKVI

11. Final assembly


Assembly
Parts
6010-016 CC hose compl. x 2
6010-021 Counter lung, left
6010-020 Counter lung, right
8

Tools/Instructions

Picture

Connect the left side CC loop


hose to the T-section of the left
counter lung.
Connect the right side CC loop
hose to the T-section of the
right counter lung.

6010-016 CC hose compl. x 2


6010-021 Counter lung, left
6010-020 Counter lung, right
6011-001 Mouthpiece

Connect the left counter lung


T-section with the inhale side
of the mouthpiece.
Connect the right counter lung
T-section with the exhale side
of the mouthpiece.

6010-047 Electronics module


Connect the O2 clean (white)
0110-002 Xstream Oxygen (EU)
HP sensor (Banjo 90 O2) to
10 or
0110-002 Xstream Dur. G 5/8 (US) a HP port on the O2 side 1st
stage.

11

6010-047 Electronics module


0110-000 Xstream Deep

Revision: 2.4 Date: 121024

Approved by: JN

0110-000 Xstream Deep


0130-004 LP hose 90 cm
12 6011-001 Mouthpiece

Connect the DIL HP sensor


(Banjo 90 DIL) to a HP port on
the DIL side 1st stage.
Connect the ADV with a LP
port on the DIL 1st stage, with
the 90 cm polyurethan hose.

0110-002 Xstream Oxygen (EU)


or
Connect a LP port on the
0110-002 Xstream Dur. G 5/8 (US)
Xstream Oxygen/Duration
13 0130-018 LP hose O2 16 cm
1st stage with the solenoid
6010-047 Electronics module
connection marked O2, using
the 16 cm O2 LP hose.

Page 123

SERVICE MANUAL - Discovery MKVI

11. Final assembly


Assembly
Parts
0110-000 Xstream Deep (US)
0130-018 LP hose DIL 16 cm
6010-047 Electronics module
14

0400-100 3L Alum. tank DIL


0400-101 3L Alum. tank O2
15

0400-100 3L Alum. tank DIL


0110-000 Xstream Deep (US)
16

Tools/Instructions

Picture

Connect a LP port on the


Xstream Deep 1st stage
with the solenoid connection
marked DIL, using the 16 cm
DIL LP hose.

With the tank bands, attach the


DIL tank to the Left side of the
round pack housing and the
O2 tank o the Right side of the
round pack housing.

Connect the Xstream Deep


(black) 1st stage to the DIL
(black) tank valve.

0400-101 3L Alum. tank O2


0110-002 Xstream Oxygen (EU)
Connect the Xstream Oxygen
or
(white) / Xtream Duration
17 0110-002 Xstream Dur. G 5/8 (US)
(green) 1st stage to the O2
(white) tank valve.
0100-006 Jetstream Octo. Mk3

19

Do NOT insert the battery in to


the electronics unit!

Revision: 2.4 Date: 121024

Approved by: JN

18

Connect the Jetstream Mk 3


Octopus to a LP port on the
Xstream Deep 1st stage.

Page 124

SERVICE MANUAL - Discovery MKVI

13. Final test and upgrade


Final test - preparations
Before you start the test procedures, please make sure that the following has been done:






- The Discovery MkVI rebreather has been assembled as per instructions


- There is enough diluent gas (air) in the diluent tank
- There is enough 100% oxygen in the oxygen tank
- The battery is sufficiently charged
- All hoses are properly connected to the different parts of the unit
- There is a scrubber inserted in the round pack housing
- You have the latest version of the Discovery MkVI user Guide available

Upgrade - preparations
To perform the upgrade procedure, you need the following:



- A computer with an IrDa port / Adapter


- The latest version of the PC config software (http://www.poseidon.com)
- The latest version of the Firmware (http://www.poseidon.com)
- Make sure the HUD is NOT mounted on the mouthpiece.

Service interval date - preparations


To set the service interval date, you need the following:
- A computer with a working IrDa port / Adapter.
- The latest verson of the PC Config software.

Revision: 2.4 Date: 121024

Approved by: JN

Page 125

SERVICE MANUAL - Discovery MKVI

12. Final test and upgrade


Final test
To perform the functionallity of the MkVI, after it has been serviced, do the following:

1. Perform an Intact Breathing Loop verification.


Inspect all breathing-hose connections to ensure that they are properly attached. The
attachment nuts should be hand tight and the nuts should be screwed down flush
against the receiver manifolds in all 8 locations (two at the top of the gas processor;
four at the shoulder ports; and two at the mouthpiece). Also at this time, make sure
the right counterlung dump valve is fully closed (turned all the way clockwise). This is
important for the pre-dive routine that automatically follows power-up.

2. Perform a Negative Loop Test


Before powering-up the electronics, it is important to check the integrity of the breathing loop.
To conduct a manual negative-pressure loop test, first secure the exhalation counterlung over-pressure checkvalve by tightening it inward to its full extent using a clockwise rotation (when viewed standing in front of the valve and looking at the valve). Place
the mouthpiece switch lever to closedcircuit (CC) position and inhale any residual gas
within the breathing loop, exhaling it through the nose to remove it from the breathing
loop. Repeat this procedure several times until you have pulled as strong a vacuum
on the breathing loop as you can, and then quickly switch the mouthpiece to OC position to hold the vacuum inside the breathing loop. The breathing hoses will contract
until no more breathing gas can be pulled from the loop.
With the mouthpiece in the OC position, observe over a period of a minute or two
whether the breathing hoses expand from their contracted state, and the counterlungs
show signs of relaxing or inflating slightly. If they do, then there is a leak somewhere
in the breathing loop. This could be caused by any number of reasons including but
not limited to any of the following:

Revision: 2.4 Date: 121024

Approved by: JN

Improper hose connection (hose not connected or incompletely connected)


Missing or failed o-ring in a hose connection or a Shoulder Port connection
Tear in a counterlung or hose
Failed overpressure checkvalve
CO2 cartridge lid not in place; or o-rings damaged or missing
Mouthpiece o-rings damaged or missing
When the Negative Loop test has been performed successfully, move to the next
step.

Page 126

SERVICE MANUAL - Discovery MKVI

12. Final test and upgrade


Final test

3. Power up the unit


As the power-up procedure may differ between different Firmware versions, its recommended that you verify the proper start-up procedure for the Firmware version
installed in the unit you are about to test, by refering to the appropreate User Guide
version.

4. Verify the Firmware version


In the MkVI User Guide, you will find instructions on how to verify what Firmware version is installed in the unit you have started up. Make a note of the version installed.
If it isnt the latest Firmware version that is installed, we recommend that you perform
a Firmware upgrade as described later in this chapter.

5. Pre-Dive Check
Allow the unit to perform a Pre-Dive check.
If the unit passes the Pre-Dive check, then it has been properly serviced.
If the unit DOES NOT pass the Pre-Dive check, make a note of the test the unit failed
on and refer to the MkVI User Guide to find whats causing the failure.
Correct any problem(s) that causes the Pre-Dive check to fail and re do steps 1 - 5 in
this list.
Do NOT return the unit to its owner, if it fails the Pre-Dive check!

Revision: 2.4 Date: 121024

Approved by: JN

The instructions in this service manual must be followed in detail step by step.
Negligence can cause serious injury or even death.

Page 127

SERVICE MANUAL - Discovery MKVI

12. Final test and upgrade


Firmware upgrade
If the MkVI that you have serviced does not contain the latest Firmware version, its
recommended that you perform a Firmware upgrade.
As the software used to perform a Firmware upgrade might differ between different Firmware
versions, its recommended that you refer to the release notes of the most current Firmware
version. DO NOT LOSE CONNECTION BETWEEN THE MkVI AND YOUR PC
DURING THE UPDATE!

12. Final test and upgrade


Service interval Date update
When the unit has passed the Pre-Dive check and the latest Firmware version has been verified
(or installed), the last thing you do it to reset the Service Interval Date.
Check the user guide for the latest version of the Diagnostics PC Software for instructions of
how to reset the Service Interval Date.
Make sure that the RTC time on the unit is set correctly, as this might cause a Service
interval test failure if it isnt.

12. Final test and upgrade


Service Documentation
We recommend that when the service and update process has been compleated, a service
check list is created and a copy of it is handed to the customer.

Revision: 2.4 Date: 121024

Approved by: JN

This protocall should contain the following information:











- Who performed the service


- When was the service performed
- Who performed the Pre-dive check after the service
- Did the unit pass the Pre-dive check (Yes/No)
- Error messages during the Pre-dive check
- Was a Firmware update performed (yes/no)
- What Firmware version was installed
- What Firmware version was it upgraded to
- Who performed the upgrade
- Has the Service Interval Date been set

The next page contains an example of a Service Checklist.


We also recommend that you do NOT return the unit to its owner in such assembled state, that
it can be Immediately dived with. Remove the CC hoses, T-connections and mouthpiece prior to
delivery, to ensure that the diver will have to assemble the unit and perform a pre-dive check.
Page 128

SERVICE MANUAL - Discovery MKVI

SERVICE CHECKLIST - DISCOVERY MKVI


Work note no:
Date recieved:
Date returned:

Unit serial no:


Battery serial no:

Service Center

Customer
Name:

Name:

Address:

Address:

Zip:

Zip:

City:

City:

Country:

Country:

Phone:

Phone:

E-mail:

E-mail:

Sign*:
*Customer signature when leaving the unit at the service center

Service performed

Notes

1st stages, Diluent & Oxygen


Octopus
LP Hoses
Mouthpiece (ADV)
CC Hoses (x 4)
Counter lungs, Compl. (x 2)
Roundpack with Canister housing, Compl.

Firmware updated:

Approved by: JN

Electronics unit, compl.

Yes

No

Yes

No

Old Firmware version:

Valves, Diluent and Oxygen

New Firmware version:

Other
Pre-Dive check passed:

Firmware update

Yes

No

Updated by:
Update date:

Revision: 2.4 Date: 121024

Error messages during Pre-Dive check:

Service interval date


Service intervall date set:

Serviced by:
Service date:

Set by:
Set date:
Page 129

SERVICE MANUAL - Discovery MKVI

14. Parts lists

Revision: 2.4 Date: 121024

Approved by: JN

First stages

Page 130

SERVICE MANUAL - Discovery MKVI

13. Parts lists

Revision: 2.4 Date: 121024

Approved by: JN

First stages
Item #

Description

Qty

0012-028
0011-037
0003-214
4778
4878
4552
2918
0011-277
4579-BK
4579-GN
4579-WE

O-ring (Deep)
O-ring, viton (Duration)
O-ring. viton (Oxygen EN 144-3)
Conn. stem 1.stage 90 Xstream Deep / Duration (G 5/8)
Conn. stem 1.stage Oxygen EN 144-3
Cup type filter long Xstream 90
O-ring (Deep)
O-ring (Duration/Oxygen)
Line protector Xstream, black
Line protector Xstream, green
Line protector Xstream, white

1
1
1
1
1
1
3
3
1
1
1

6010-233

Housing 1.stage 90 Xstream

4555
0000-149
0015-059
0016-036
4758
4760
4764
4777
4563
0015-012
4762
4559
4564

Spring for ball Xstream


Ruby Ball 1.stage Xstream
O-ring (Deep)
O-ring, viton (Duration/Oxygen)
Zytel valve seat Xstream
Valve seat holder Xstream
Valve seat spring Xstream
Lower pin guide Xstream
Pin bushing 1.stage Xstream
O-ring
Upper pin guide Xstream
Actuating pin, Xstream
Roll.diaphragm 1.stage Xstream

1
1
1
1
1
1
1
1
1
1
1
1
1

4565

Pressure plate 1.stage Xstream

4763
4570-BK
4570-GN
4570-WE
0000-140
4568

Adjust. spring 1.stage Xstream


Barrier 1.stage Xstream black
Barrier 1.stage Xstream green
Barrier 1.stage Xstream white
Cover Xstream 1st stage, chrome
Screw cover M3x10 Xstream

1
1
1
1
1
3

0000-141

Adjustment screw, chrome

2680

Blindscrew UNF7/16

2679

Blindscrew UNF3/8

0010-353
0013-164

O-ring (Deep)
O-ring, EPDM (Duration/oxygen)

5
5

4576-BK
4576-GN
0000-150

Wheel G5/8 Xstream, black


Wheel G5/8 Xstream, green
Wheel Xstream, White (Oxygen EN 144-3)

1
1
1

3726

Valve sealing

3725

Valve piston

1180

Pressure spring

3727

Locking screw

Page 131

SERVICE MANUAL - Discovery MKVI

13. Parts lists

Revision: 2.4 Date: 121024

Approved by: JN

0100-006 Jetstream Mk3 Octopus

Page 132

SERVICE MANUAL - Discovery MKVI

13. Parts lists


# Item #

Description

Qty

0000-130

Hose Adapter

0130-002

LP hose, 9/16 - 90 cm / 35,4 inch

0010-355

O-ring

2857

Low pressure valve housing

0010-025

O-ring

3440

Valve insert

0012-007

O-ring

2974

Valve housing nut

2875

Stop screw

10 2787

Rubber plate

11 0015-019

O-ring

12 2839

Valve tube

13 1896

O-ring

14 2786

Servo valve, complete

15 3088

Low pressure valve, complete (parts 3 - 14)

16 3202

Mouth piece

17 1167

Locking strap

18 2711

Switch

19 0010-018

O-ring

20 3121

Housing

21 2794

Lock washer

22 2712

Diaphragm cam

23 3132

Housing, 2nd stage, incl parts 18-22, Yellow

24 2578

Diaphragm

25 2989

Cover for 2nd stage, yellow

26 2851

Screw

27 2853

Purge button

28 3104

Housing complete incl. parts 16-27, Yellow

Revision: 2.4 Date: 121024

Approved by: JN

0100-006 Jetstream Mk3 Octopus

Page 133

SERVICE MANUAL - Discovery MKVI

13. Parts lists


LP Hoses

Revision: 2.4 Date: 121024

Approved by: JN

Item #

Description

Qty

0130-017 - LP hose 16 cm DIL

0130-018 - LP hose 16 cm O2 (White - EU version)

0130-019 - LP hose 16 cm O2 (Green - US version)

0130-004 - LP hose Polyurethan 9/16-18 90cm

0130-002 - LP hose Mk3 - 9/16-18 90cm (Octopus)

0010-353 - O - ring

0010-009 - O-ring

0011-276 O-ring Viton

0010-009 - O-ring

0011-006 - O-ring Viton

1
Page 134

SERVICE MANUAL - Discovery MKVI

13. Parts lists


Mouthpiece: 6011-001

Description

6010-000

4532

Qty

Mouthpiece house assembly

Mouthpiece AIR

6010-005

OC outlet

0000-130

Hose adapter

1167

Cable tie

Revision: 2.4 Date: 121024

Approved by: JN

Item # Article #

Page 135

SERVICE MANUAL - Discovery MKVI

13. Parts lists


Mouthpiece: House assembly

Description

Qty

6010-001

Mouthpiece house

4536

Diaphragm cover

4533

Membrane with washer

0000-232

Membrane mouthpiece

6010-013

Membrane holder complete

6010-010

DV Switch

Revision: 2.4 Date: 121024

Approved by: JN

Item # Article #

Page 136

SERVICE MANUAL - Discovery MKVI

13. Parts lists


Mouthpiece: DV Switch (6010-010)

Description

Qty

6010-104

Lock nut

6010-257

Plastic washer

6010-012

Barrel magnet

0015-245

O-ring

6010-114

Helix block

0010-120

O-ring

Revision: 2.4 Date: 121024

Approved by: JN

Item # Article #

Page 137

SERVICE MANUAL - Discovery MKVI

13. Parts lists

Mouthpiece: Low pressure valve MkVI (0005-000)

Item # Article #

Description

Qty

0000-148

Valve house nut

0011-278

O-ring

0012-016

O-ring

0013-001

O-ring

0013-009

O-ring

0013-351

O-ring

2787-07

Rubber plate

2857

Low pressure valve house

2875

Stop screw

10

3440 07

Valve insert

11

2839

Valve tube

12

2786 07

Servo valve

Revision: 2.4 Date: 121024

Approved by: JN

Page 138

SERVICE MANUAL - Discovery MKVI

13. Parts lists


Mouthpiece: Membrane holder complete (6010-013)

Item # Article #

Description

Qty

6010-116

Membrane holder

0010-032

O-ring

6010-268

Air membrane

Revision: 2.4 Date: 121024

Approved by: JN

Page 139

SERVICE MANUAL - Discovery MKVI

13. Parts lists

Revision: 2.4 Date: 121024

Approved by: JN

Breathing loop components: 6010-020 Right counter lung

Item
1
2
3
4
5
6
7
8

Part No
6010-008
6010-011
6010-018
6010-133
6010-277
0000-180
0013-187
0000-182

Description
Lung shell right
T-Section
Innerbladder right
T-Lunginsert
Ring nut valve insert
Automatic outlet valve
O-ring
Valve patch Flexisuit

Nmbr
1
1
1
1
1
1
2
1

Page 140

SERVICE MANUAL - Discovery MKVI

13. Parts lists

Revision: 2.4 Date: 121024

Approved by: JN

Breathing loop components: 6010-021 Left counter lung

Item
1
2
3
4
5
6
7

Part No
6010-009
6010-011
6010-019
6010-133
6010-273
6010-277
0013-187

Description
Lung shell left
T-Section
Innerbladder left
T-Lunginsert
Blind insert
Ring nut valve insert
O-ring

Nmbr
1
1
1
1
1
2
4

Page 141

SERVICE MANUAL - Discovery MKVI

13. Parts lists

Revision: 2.4 Date: 121024

Approved by: JN

Breathing loop components: 6010-011 T-section

Item
1
2
3
4

Part No
6010-131
6010-130
0010-140
0014-034

Description
T-top
T-Bone
O-ring
O-ring

Nmbr
1
1
1
1

Page 142

SERVICE MANUAL - Discovery MKVI

13. Parts lists


Breathing loop components: 0132-002 CC hose (x 4)
Item Part No
1
0132-002*
2
0013-261

Description
CC hose
O-ring

Revision: 2.4 Date: 121024

Approved by: JN

*Replaced hose 6010-016 in March 2010

Nmbr
1
2

Page 143

SERVICE MANUAL - Discovery MKVI

13. Parts lists

Revision: 2.4 Date: 121024

Approved by: JN

6010-006 Round pack

Item
1
2
3
4
5
6
7
8
9
11

Part No
6010-139
6010-265
0015-533
6010-192
6010-191
0014-013
0013-265
6010-129
0310-108
0010-402

Description
Top half
Top support
O-ring
CL_Interface
Diverter
O-ring
O-ring
Screw Delta PT20x8 WN5452
Screw Delta PT 40x8
O-ring

Nmbr
1
1
1
2
1
1
2
12
4
2
Page 144

SERVICE MANUAL - Discovery MKVI

13. Parts lists

Revision: 2.4 Date: 121024

Approved by: JN

6010-138 Round Pack Housing

Item
1
2
3

Part No
6010-138
0310-134
6010-246

Description
Round Pack Housing
Screw MRT M6x40
Heli coil plus

Nmbr
1
6
4
Page 145

SERVICE MANUAL - Discovery MKVI

13. Parts lists

Revision: 2.4 Date: 121024

Approved by: JN

6011-011 Molprod Bottom

Item
1
2
3
4
5
6
7

Part No
6010-214
0014-293
6010-236
0310-108
6010-176
0015-533
6010-264

Description
Can bottom
O-ring
Sponge
Screw Delta PT 40x8
Screw foot
O-ring
Sponge washer

Nmbr
1
1
1
1
4
2
1

Page 146

SERVICE MANUAL - Discovery MKVI

13. Parts lists

Revision: 2.4 Date: 121024

Approved by: JN

6011-012 Molprod Top

Item
1
2
3
4

Part No
6010-236
0014-292
6010-215
0014-293

Description
Sponge
O-ring
Can top
O-ring

Nmbr
1
1
1
1

Page 147

SERVICE MANUAL - Discovery MKVI

13. Parts lists


6010-047 Electronics module

Revision: 2.4 Date: 121024

Approved by: JN

Item
10
11
12

Part No
6010-205
0013-215
0013-214

Description
O2 sensor base
O-ring
O-ring

Item
1
2
3
4
5
6
7
8
9

Part No
6010-036
6010-039
0015-467
0015-461
6011-005
6011-004
6010-044
6010-045
6010-014

Nmbr
1
1
1

Description
Electronica module
2 sensor base compl.
O-ring
O-ring
Battery pack
To the Display
To the HP sensor w. banjo Dil
To the HP sensor w. banjo O2
To the HUD

Nmbr
1
2
1
1
1
1
1
1
1
Page 148

SERVICE MANUAL - Discovery MKVI

13. Parts lists

Revision: 2.4 Date: 121024

Approved by: JN

6011-005 Battery pack and 6011-015 Battery charger

Item
1
2
3

Part No
6011-005
6011-015
0013-038

Description
Battery pack
Battery charger
O-ring

Nmbr
1
1
1

Page 149

SERVICE MANUAL - Discovery MKVI

13. Parts lists


0005-006 Banjo 90 HP O2 and 3291 Banjo 90 HP

Revision: 2.4 Date: 121024

Approved by: JN

0005-006
Item
1
2a
2b
3
4
5a
5b
6

Part No
3292
0011-276
0010-353
3293
3294
0011-277
0010-354
1095

3291
Description
Banjo screw
O-ring Viton (-)
O-ring
Banjo house
Spacer
O-ring Viton (2918 59)
O-ring (2918)
Strangle screw

Nmbr
1
2
2
1
1
1
1
1

Page 150

Poseidon Diving Systems AB


P.O Box 8050
421 08 Vstra Frlunda
Sweden
htp://www.poseidon.com
[email protected]

You might also like