TM2500 & TM2500+

Mobile Gas Turbine Generator

December, 2008

Product Description
23-31 MW mobile gas
turbine generator
Easily transported
by land, air, or sea
50 or 60 Hz flexibility
Liquid or natural gas fuel
Low emissions (25 ppm NOx)
Low noise 88 dBA

2/

Whats Inside?

LM 2 5 0 0 +
B ee fe d u p LP T d isks & re a r sh a ft
Sta g e Z ero B lisk
N e w C o m p re sso r F ro n t
F ra m e & F orw a rd ca se

Re -d esig n e d
H P T, TM F & L P T C a se

GE LM2500/+ Gas Turbine


2,000+ engines worldwide
More than 97M operating hrs
Recognized as the industry leader
in its size class

R e-d e sig n e d
C D P S ea l

Re -d e sig n e d L P T a irfo ils

~ 1 3 in c h e s

LM 25 0 0

Brush Electrical Generator


Air-cooled generator w/ brushless
excitation
Suitable for Class 1, Group D, Div. 2
areas
60 and 50 Hz operation
Rated at 32,550 KVA @ 0.90 pf, 59 deg. F
cooling air, 13.8 kV, 60 Hz. (11.5 kV @ 50
Hz.)
3/

TM2500 General Arrangement


Proven 4-trailer system
Exhaust
Trailer

Minimal foundation
requirements & prep

Exhaust
Air Out

Quick set-up

Turbine Enclosure Air Supply

Steps to
Turbine

Inlet Filter Trailer

Turbine
Inlet Air
Supply

Turbine Generator Trailer

Natural
Gas
Supply

Auxiliary Trailer

NOx Water
Supply

Liquid Fuel
Supply

Aux.
Power
Supply

13.8 kV
Out

Steps to
Control
Room
4/

Typical TM2500 Installation


Entrance
Control Room
13.8 - 138 KV
Transformer
33 MVA
(1 x LM2500)
138 kV Breaker
13.8 - 138 KV
Transformer
80 MVA
(4 x LM2500)
13.8 - 480 KV
Transformer
(Aux. Power)

First TM2500 Installation


5 units / Gas Fuel / 60 Hz
Chicago, IL
Summer, 2000

13.8 - 4.16 KV
Transformer
(gas compressors)
3 x Compressor
Starters
3 x Electric Gas
Compressors +
Control Skid

Demin Water
Supply

Natural Gas Supply


5/

Proven Experience
Since 2000, 29 TM2500 rental projects in 12 countries
Qty.
5
3
2
5
5
5
1
3
3
2
7
10
3
6
1
6
5
5
5
2
5
4
1
1
1
3
3
4
7
4

Year
2000
2000
2000
2001
2001
2001
2001
2001
2001
2001
2001
2002
2002
2003
2003
2003
2003
2003
2003
2003
2004
2004
2005
2005
2005
2006
2006
2006
2007
2008

City
Chicago, IL
Cork
Mayo
Tucson, AZ
Phoenix, AZ
Salt Lake City, UT
Crete
San Nicolaas
Cork
Mayo
Tacoma, WA
Long Island, NY
Stamford, CT
Long Island, NY
Norwalk, CT
Guadalajara
Accra
Acapulco
Grafton, Ontario
Long Island, NY
Athens
Perth
Port Fourchon, LA
Beaumont, TX
Ajaccio
Mossel Bay
Stamford, CT
Barinas
Lahore
Buenos Aires

Country
Fuel Freq. Term (mos)
USA
Gas
60
3
Ireland
Liq
50
6
Ireland
Liq
50
6
USA
Gas
60
3
USA
Gas
60
3
USA
Gas
60
3
Greece
Liq
50
4
Aruba
Liq
60
6
Ireland
Liq
50
6
Ireland
Liq
50
6
USA
Dual 60
15
USA
Liq
60
3
USA
Liq
60
4
USA
Liq
60
3
USA
Liq
60
5
Mexico
Liq
60
8
Ghana
Liq
50
5
Mexico
Liq
60
9
Canada
Gas
60
5
USA
Liq
60
3
Greece
Liq
50
3
Australia
Liq
50
5
USA
Liq
60
4
USA
Gas
60
3
Corsica
Liq
50
10
S. Africa
Liq
50
7
USA
Liq
60
28
Venezuela Gas
50
24
Pakistan
Gas
50
36
Argentina Gas
60
36

Versatility
Flexibility
Reliability
6/

TM2500 Installations

Venezuela

Arizona

Pakistan

Arizona

Ireland

7/

Introducing the TM2500+

8/

Whats New?
LM2500 PLUS gas turbine
Up to 30% more power!
Two-trailer design
75% reduction in footprint
Improved interconnection design
Faster installation and set-up

9/

31% More Power at 60 Hz !


38
LM2500 (60 Hz)

36

LM2500+ (60 Hz)

34

170ER (F 60 Hz) (Generator Limit)

32
30
MW

28

31%

26
24
22
20
0

20

40

60

80

100

Ambient Temperature deg. F

10 /

13% More Power at 50 Hz !


34
LM2500 (50 Hz)

32

LM2500+ (50 Hz)


30

170ER (F 50 Hz)

(Generator Limit)

28
MW

26

13%
24
22
20
0

20

40

60

80

100

Ambient Temperature deg. F


50 Hz Performance
11 /

Whats New?
LM2500 PLUS gas turbine
Up to 31% more power!
Two-trailer design
Smaller footprint
Improved interconnection design
Faster installation and set-up

12 /

New Two-Trailer Design


Top-Mounted Inlet
& Exhaust
Assemblies

LM2500+ Gas
Turbine

13 /

TM2500+ General Arrangement


Exhaust Stack

Generator
Inlet &
Exhaust

Inlet Filter
Assembly

Main
Trailer
Switchgear

Trailer
Gooseneck

Inlet
Plenum

Transportation
Jeep

GE LM2500+
Gas Turbine

Hydraulic
Starter

Auxiliary
Trailer

Brush BDAX
62-170ER
Generator
Lube Oil
Coolers

Transportation
Stinger

Turbine Enclosure
Fire Suppression
Control Room
& Battery
Room

Fuel/Water
Pumps
14 /

TM2500/+ Footprint
107 x 67

78 x 21

77% Reduction in Installed Footprint


15 /

Whats New?
LM2500 PLUS gas turbine
Up to 31% more power!
Two-trailer design
Smaller footprint
Improved interconnection design
Faster installation and set-up

16 /

Interconnection Improvements for Faster


Set-up
Exhaust Duct
Assembly

Improved inlet &


exhaust connections
for quicker installation
& set-up

Inlet Filter
Assembly

Can be set up
in 24 hours

Turbine Enclosure
Assembly

Inlet Plenum
17 /

Back-up

18 /

Site Preparation / Foundation


Level within 6 inches per 100 feet
Solid crushed gravel with 1 steel plates
Adequate access / space, well-lit, secure

19 /

Fuel / Water Connections


Natural Gas
Supply (3 pipe)

Auxiliary Trailer
(top view)

Auxiliary Trailer
(side view)

Liquid Fuel
Supply (2 pipe)

NOx Water
Supply
(2 pipe)

20 /

Electrical Connections
Generator output 13.8 kV @ 60
Hz (11.5 kV @ 50 Hz.)
Auxiliary power requirement
480V, 60 Hz, to motor control
center main circuit breaker (250
kW)

High Voltage
Termination

21 /

Grounding
Customer furnished grounding system
GE provides ground grid specification
and interconnection requirements

4 trailer to ground

Grounding Block
1/4 in thread bolt,
3/8 in deep

8 trailer to ground

26 trailer to trailer

6 trailer to
ground

5 trailer to trailer

5 trailer to trailer
15 trailer to trailer
35 trailer to ground
22 /

Customer Interface Details (TM2500)


Fuel
Gas supply pressure is 395 (+/- 20) PSIG at a rate of 12,000 pph (250 mmbtu/hr or 6
mscf/day)
Liquid Fuel (diesel) supply pressure is 30 (+/- 10) PSIG, up to 40 GPM (max.)

Water (for NOx suppression)


Minimum supply pressure is 15 PSIG up to 28 GPM (max.)

Inlet/Exhaust Air
Nominal inlet air flow 150,000 CFM (120,000 turbine / 30,000 enclosure ventilation)
Exhaust stack height is 20 when fully assembled

Flange dimensions 96 x 96)


Exhaust gas flow 490,000-550,000 lbs/hr @ 980F
Emissions
Liquid Fuel: 42 ppm NOx with water injection
Gas Fuel: 25 ppm NOx with water injection
Noise
Approximately 88 dBa
Waste
Lubricating oils (turbine & generator)
Turbine wash detergent and rinse water
23 /

TM2500 Unit Installation Equipment

Snorkel Lift (Telescopic Boom)

Front Loader w/forks to move sea containers

(Lull) 6,000 lb. Variable Reach Forklift

25-45 Ton Crane


24 /