Smart-UPS and Matrix-UPS APP : Unknown Contact : Unknown Location : unknow User : Administrator Up Time : 13 Days 10 Hours 33 Minutes. Smart-ups RT 8000 XL named UPS_IDEN : On line, no alarms present.

Uploaded by

Sohail
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as TXT, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
178 views11 pages

Atc Ups Apc

Smart-UPS and Matrix-UPS APP : Unknown Contact : Unknown Location : unknow User : Administrator Up Time : 13 Days 10 Hours 33 Minutes. Smart-ups RT 8000 XL named UPS_IDEN : On line, no alarms present.

Uploaded by

Sohail
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as TXT, PDF, TXT or read online on Scribd
You are on page 1/ 11

User Name :

User Name : apc


Password : ***
American Power Conversion

Network Management Card AOS

(c) Copyright 2008 All Rights Reserved Smart-UPS & Matrix-UPS APP

v3.6.1
v3.5.8

------------------------------------------------------------------------------Name

: Unknown

Date : 07/24/2005

Contact

: Unknown

Time : 14:08:44

Location : Unknown

User : Administrator

Up Time

Stat : P+ N? A+

: 13 Days 10 Hours 33 Minutes

Environment : Thresholds Disabled, Contact Alarms Disabled, Relay OK


Smart-UPS RT 8000 XL

named UPS_IDEN : On Line, No Alarms Present

------- Control Console ------------------------------------------------------1234-

Device Manager
Network
System
Logout

<ESC>- Main Menu, <ENTER>- Refresh, <CTRL-L>- Event Log


> 3
------- System ---------------------------------------------------------------1234567-

User
Identification
Date/Time
Tools
RADIUS
Modem
About System

<ESC>- Back, <ENTER>- Refresh, <CTRL-L>- Event Log


> 3
------- Date/Time ------------------------------------------------------------Date

: 07/24/2005

Format : mm/dd/yyyy
DST
: Disabled

Time : 14:10:22

NTP
12345-

: Disabled
Manual
Network Time Protocol (NTP)
Update Time Using NTP Now
Date Format
Daylight Saving Time (DST)

?- Help, <ESC>- Back, <ENTER>- Refresh, <CTRL-L>- Event Log


> 3
------- Date/Time ------------------------------------------------------------Date

: 07/24/2005

Time : 14:10:55

Format : mm/dd/yyyy
DST
: Disabled
NTP
: Disabled
12345-

Manual
Network Time Protocol (NTP)
Update Time Using NTP Now
Date Format
Daylight Saving Time (DST)

?- Help, <ESC>- Back, <ENTER>- Refresh, <CTRL-L>- Event Log


> 1
------- Manual ---------------------------------------------------------------Date

: 07/24/2005

Time : 14:11:07

Format : mm/dd/yyyy
DST
: Disabled
NTP
: Disabled
1- Date (mm/dd/yyyy): 07/24/2005
2- Time (hh:mm:ss) : 14:11:07
3- Accept Changes :
?- Help, <ESC>- Back, <ENTER>- Refresh, <CTRL-L>- Event Log
> 1
Date (mm/dd/yyyy) : 08/24/2014
------- Manual ---------------------------------------------------------------Date

: 07/24/2005

Format : mm/dd/yyyy
DST
: Disabled
NTP
: Disabled
1- Date (mm/dd/yyyy): 08/24/2014
2- Time (hh:mm:ss) : 14:11:07

Time : 14:12:06

3- Accept Changes

: Pending

?- Help, <ESC>- Cancel Changes, <ENTER>- Refresh, <CTRL-L>- Event Log


> 2
Time (hh:mm:ss) : 08:54:01
------- Manual ---------------------------------------------------------------Date

: 07/24/2005

Time : 14:13:38

Format : mm/dd/yyyy
DST
: Disabled
NTP
: Disabled
1- Date (mm/dd/yyyy): 08/24/2014
2- Time (hh:mm:ss) : 08:54:01
3- Accept Changes : Pending
?- Help, <ESC>- Cancel Changes, <ENTER>- Refresh, <CTRL-L>- Event Log
> 3
------- Manual ---------------------------------------------------------------Date

: 08/24/2014

Time : 08:54:02

Format : mm/dd/yyyy
DST
: Disabled
NTP
: Disabled
1- Date (mm/dd/yyyy): 08/24/2014
2- Time (hh:mm:ss) : 08:54:
3- Accept Changes : Success
?- Help, <ESC>- Back, <ENTER>- Refresh, <CTRL-L>- Event Log
>
------- Date/Time ------------------------------------------------------------Date

: 08/24/2014

Time : 08:54:21

Format : mm/dd/yyyy
DST
: Disabled
NTP
: Disabled
12345-

Manual
Network Time Protocol (NTP)
Update Time Using NTP Now
Date Format
Daylight Saving Time (DST)

?- Help, <ESC>- Back, <ENTER>- Refresh, <CTRL-L>- Event Lo


>

------- System ---------------------------------------------------------------1234567-

User Manager
Identification
Date/Time
Tools
RADIUS
Modem
About System

<ESC>- Back, <ENTER>- Refresh, <CTRL-L>- Event Log


> 4
------- Tools ----------------------------------------------------------------123456-

Reboot Management Interface


Reset to Defaults
Reset to Defaults Except TCP/IP
Reset Only TCP/IP to Defaults
Delete SSH Host Keys a
File Transfer

<ESC>- Back, <ENTER>- Refresh, <CTRL-L>- Event Log


>
------- System ---------------------------------------------------------------1234567-

User Manager
Identification
Date/Time
Tools
RADIUS
Modem
About System

<ESC>- Back, <ENTER>- Refresh, <CTRL-L>- Event Log


>
------- Control Console ------------------------------------------------------1234-

Device Manager
Network
System
Logout

<ESC>- Main Menu, <ENTER>- Refresh, <CTRL-L>- Event Log


> 1
------- Device Manager -------------------------------------------------------1- Smart-UPS RT 8000 XL

2- Environment
<ESC>- Back, <ENTER>- Refresh, <CTRL-L>- Event Log
> 1
------- Smart-UPS RT 8000 XL -------------------------------------------------Status of UPS : On Line, No Alarms Present
Last Transfer : Unacceptable utility voltage rate of change
-----------------------------------------------------Input Voltage

: 223.2 VAC

Input Frequency

: 49.97 Hz

Output Voltage

: 231.6 VAC

Output Frequency

: 49.97 Hz

Load Power

: 009.0 % Watts

Battery Voltage

: 218.1 VDC

Max Line Voltage : 223.2 VAC

Battery Capacity

: 100.0 %

Min Line Voltage : 220.3 VAC

Runtime Remaining

: 0017 min

Apparent Load Power : 000.0 % VA


Internal Temp
: 026.8 C
-----------------------------------------------------------------------

12345-

Self-Test Result : Not available

Calibration Result : Not available

Self-Test Date

Calibration Date

: 07/21/2005

: Unknown

Control
Diagnostics
Configuration
Detailed Status
About UPS

<ESC>- Back, <ENTER>- Refresh, <CTRL-L>- Event Log


> 1
------- Control --------------------------------------------------------------Status of UPS : On Line, No Ala
1234567-

Turn UPS Off


Turn UPS Off Gracefully
Reboot UPS
Reboot UPS Gracefully
Put UPS To Sleep
Put UPS To Sleep Gracefully
Put UPS In Bypass

?- Help, <ESC>- Back, <ENTER>- Refresh, <CTRL-L>- Event Log

>
------- Smart-UPS RT 8000 XL -------------------------------------------------Status of UPS : On Line, No Alarms Present
Last Transfer : Unacceptable utility voltage rate of change
----------------------------------------------------Input Voltage

: 223.2 VAC

Input Frequency

: 49.97 Hz

Output Voltage

: 230.4 VAC

Output Frequency

: 49.97 Hz

Load Power

: 009.0 % Watts

Battery Voltage

: 218.1 VDC

Max Line Voltage : 223.2 VAC

Battery Capacity

: 100.0 %

Min Line Voltage : 220.3 VAC

Runtime Remaining

: 0017 min

Apparent Load Power : 000.0 % VA


Internal Temp
: 026.8 C
-----------------------------------------------------------------------

12345-

Self-Test Result : Not available

Calibration Result : Not available

Self-Test Date

Calibration Date

: 07/21/2005

: Unknown

Control
Diagnostics
Configuration
Detailed Status
About UPS

<ESC>- Back, <ENTER>- Refresh, <CTRL-L>- Event Log


> 2
------- Diagnostics ----------------------------------------------------------Status of UPS : On Line, No Ala
1- UPS Self-Test
2- Start Runtime Calibration
3- Test UPS Alarm
?- Help, <ESC>- Back, <ENTER>- Refresh, <CTRL-L>- Event Log
>
------- Smart-UPS RT 8000 XL -------------------------------------------------Status of UPS : On Line, No Alarms Present

Last Transfer : Unacceptable utility voltage rate of change


----------------------------------------------------------------------Input Voltage

: 223.2 VAC

Input Frequency

: 49.97 Hz

Output Voltage

: 231.6 VAC

Output Frequency

: 49.97 Hz

Load Power

: 009.0 % Watts

Battery Voltage

: 217.0 VDC

Max Line Voltage : 223.2 VAC

Battery Capacity

: 100.0 %

Min Line Voltage : 220.3 VAC

Runtime Remaining

: 0017 min

Apparent Load Power : 000.0 % VA


Internal Temp
: 026.8 C
-----------------------------------------------------------------------

12345-

Self-Test Result : Not available

Calibration Result : Not available

Self-Test Date

Calibration Date

: 07/21/2005

: Unknown

Control
Diagnostics
Configuration
Detailed Status
About UPS

<ESC>- Back, <ENTER>- Refresh, <CTRL-L>- Event Log


> 3
------- Configuration --------------------------------------------------------UPS Name

: UPS_IDEN

Battery Date

: 01/30/09

-----------------------------------Output Voltage : 230 VAC

Shutdown Delay

: 020 sec

Upper Bypass

: 253 VAC

Return Delay

: 000 sec

Lower Bypass

: 161 VAC

Low-Battery Duration : 002 min

Output Freq

: Auto

Sleep Time

Alarm kVA Over : Auto kVA

: 0.0 hrs

Alarm Runtime Under : 0.0 min

Shutdown Mode : Normal


----------------------------------------------------------------------Auto Self-Test : Every 14 days

External Batteries

: 001

Audible Alarm : Power Fail


123456-

Return Batt Capacity : 000 %

Battery
Line Transfer
Shutdown Parameters
General
Reset UPS to Defaults
Sync Control Group (SCG)

?- Help, <ESC>- Back, <ENTER>- Refresh, <CTRL-L>- Event Log


> 1
------- Battery --------------------------------------------------------------Battery Date

: 01/30/09

External Batteries : 001

1- Battery Date
: 01/30/09
2- External Batteries: 001
3- Accept Changes
:
?- Help, <ESC>- Back, <ENTER>- Refresh, <CTRL-L>- Event Log
> 1
Battery Date : 08/24/14
------- Battery --------------------------------------------------------------Battery Date

: 01/30/09

External Batteries : 001

1- Battery Date
: 08/24/14
2- External Batteries: 001
3- Accept Changes
: Pending
?- Help, <ESC>- Cancel Changes, <ENTER>- Refresh, <CTRL-L>- Event L
> 3
Attempting to issue command, please wait...

------- Battery --------------------------------------------------------------Battery Date

: 08/24/14

External Batteries : 001

1- Battery Date
: 08/24/14
2- External Batteries: 001
3- Accept Changes
: Success
?- Help, <ESC>- Back, <ENTER>- Refresh, <CTRL-L>- Event Log
>

------- Configuration --------------------------------------------------------UPS Name

: UPS_IDEN

Battery Date

----------------------------------------------------------------------Output Voltage : 230 VAC

Shutdown Delay

: 020 sec

Upper Bypass

: 253 VAC

Return Delay

: 000 sec

Lower Bypass

: 161 VAC

Low-Battery Duration : 002 min

Output Freq

: Auto

Sleep Time

Alarm kVA Over : Auto kVA

: 0.0 hrs

Alarm Runtime Under : 0.0 min

Shutdown Mode : Normal


-----------------------------------------------------------------------

123456-

Auto Self-Test : Every 14 days

External Batteries

: 001

Audible Alarm : Power Fail

Return Batt Capacity : 000 %

Battery
Line Transfer
Shutdown Parameters
General
Reset UPS to Defaults
Sync Control Group (SCG)

?- Help, <ESC>- Back, <ENTER>- Refresh, <CTRL-L>- Event Log


> [A
------- Smart-UPS RT 8000 XL -------------------------------------------------Status of UPS : On Line, No Alarms Present
Last Transfer : Unacceptable utility voltage rate of change
----------------------------------------------------------------------Input Voltage

: 223.2 VAC

Input Frequency

: 49.96 Hz

Output Voltage

: 231.6 VAC

Output Frequency

: 49.96 Hz

Load Power

: 010.0 % Watts

Battery Voltage

: 217.0 VDC

Max Line Voltage : 223.2 VAC

Battery Capacity

: 100.0 %

Min Line Voltage : 220.3 VAC

Runtime Remaining

: 0017 min

Apparent Load Power : 000.0 % VA

Internal Temp
: 027.4 C
-----------------------------------------------------------------------

12345-

Self-Test Result : Not available

Calibration Result : Not available

Self-Test Date

Calibration Date

: 07/21/2005

: Unknown

Control
Diagnostics
Configuration
Detailed Status
A

<ESC>- Back, <ENTER>- Refresh, <CTRL-L>- Event Log


>
------- Device Manager -------------------------------------------------------1- Smart-UPS RT 8000 XL
2- Environment
<ESC>- Back, <ENTER>- Refresh, <CTRL-L>- Event Log
>
------- Control Console ------------------------------------------------------1234-

Device Manager
Network
System
Logout

<ESC>- Main Menu, <ENTER>- Refresh, <CTRL-L>- Event Log


>
American Power Conversion

Network Management

(c) Copyright 2008 All Rights Reserved Smart-UPS & Matrix-UPS APP

v3.5.8

------------------------------------------------------------------------------Name

: Unknown

Date : 08/24/2014

Contact

: Unknown

Time : 08:59:27

Location : Unknown

User : Administrator

Up Time

Stat : P+ N? A+

: 13 Days 10 Hours 44 Minutes

Environment : Thresholds Disabled, Contact Alarms Disabled, Relay OK


Smart-UPS RT 8000 XL

named UPS_IDEN : On Line, No Alarms Present

------- Control Console ------------------------------------------------------1234-

Device Manager
Network
System
Logout

<ESC>- Main Menu, <ENTER>- Refresh, <CTRL-L>- Event Log


>
American Power Conversion
Network Management Card AOS
v3.6.1
(c) Copyright 2008 All Rights Reserved Smart-UPS & Matrix-UPS APP
v3.5.8
------------------------------------------------------------------------------Name
: Unknown
Date : 08/24/2014
Contact : Unknown
Time : 08:59:32
Location : Unknown
User : Administrator
Up Time : 13 Days 10 Hours 44 Minutes
Stat : P+ N? A+
Environment : Thresholds Disabled, Contact Alarms Disabled, Relay OK
Smart-UPS RT 8000 XL
named UPS_IDEN : On Line, No Alarms Present
------- Control Console ------------------------------------------------------1234-

Device Manager
Network
System
Logout

<ESC>- Main Menu, <ENTER>- Refresh, <CTRL-L>- Event Log


> 4
Logging out.