MATLAB-Simulink Implementation and Analysis of Three Pulse-Width
MATLAB-Simulink Implementation and Analysis of Three Pulse-Width
by
Phuong Hue Tran
A thesis
submitted in partial fulfillment
of the requirements for the degree of
Master of Science in Electrical Engineering
Boise State University
May 2012
c 2012
Phuong Hue Tran
ALL RIGHTS RESERVED
Thesis Title:
11 May 2012
The following individuals read and discussed the thesis submitted by student Phuong Hue
Tran, and they evaluated her presentation and response to questions during the final oral
examination. They found that the student passed the final oral examination.
Said Ahmed-Zaid, Ph.D.
The final reading approval of the thesis was granted by Said Ahmed-Zaid, Ph.D., Chair of
the Supervisory Committee. The thesis was approved for the Graduate College by John
R. Pelton, Ph.D., Dean of the Graduate College.
ACKNOWLEDGMENTS
I would like to take this opportunity to express my sincere appreciation to all the people
who were helpful in making this thesis successful. First of all, I would like to express
my gratitude to my advisor, Dr. Said Ahmed-Zaid for his valuable comments, guidance,
and discussions that guided me well in the process of my thesis. I am thankful to my
committee members ( Dr. John Chiasson and Dr. Elisa Barney Smith) for their comments
and suggestions and their willingness to be my committee members.
Most importantly, I would like to express my deepest thanks to my family for giving
me a life of opportunities and backing me up in every corner where my life has been
difficult. Thanks for all their care, support, encouragement, and inspiration all along in my
academic endeavors.
iv
ABSTRACT
TABLE OF CONTENTS
ABSTRACT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.1
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.2
Literature Review . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.3
Research Motivation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.4
Thesis Organization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.1
Sinusoidal PWM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.1.1
2.1.2
2.2
Third-Harmonic-Injection PWM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
2.2.1
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
3.2
3.3
3.3.2
3.3.3
Sector Determination . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
3.3.4
Time Durations Ta , Tb , T0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
3.3.5
3.3.6
4
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
4.2
Over-Modulation Mode 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
4.3
Over-Modulation Mode 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Simulation Results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
5.1
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
5.2
Sinusoidal PWM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
5.3
THIPWM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
5.4
5.5
Simulation Results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
6.2
Conclusion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
7.2
REFERENCES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
vii
LIST OF TABLES
3.1
3.2
3.3
3.4
Sector Definition. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
3.5
3.6
3.7
Switching Pulse Pattern for the Three Phase for Each Sector . . . . . . . . . . . . 41
3.8
4.1
6.1
6.2
6.3
viii
LIST OF FIGURES
2.1
2.2
2.3
Three-Phase Sinusoidal PWM: a). Reference Voltages (a,b,c) and Triangular Wave b). Vao , c) Vbo , d) Vco e) Line-to-Line Voltages [27]. . . . . . . . . .
2.4
2.5
Reference Voltages (a,b,c), Triangular Waveforms (VT ), and Output Voltage (Vao ,Vbo ,Vco ). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
3.1
3.2
3.3
3.4
3.5
3.6
3.7
ix
4.2
4.3
4.4
4.5
4.6
4.7
5.1
5.5
5.6
5.7
5.8
5.9
, Voltages and Modulation Index are Detail for Block 2 in Figure 5.7. . . 64
6.2
6.3
Locus of SPWM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
6.4
6.5
6.6
6.7
6.8
6.9
xi
CHAPTER 1
INTRODUCTION
1.1
Introduction
Pulse-width modulation (PWM) is a technique where the duty ratio of a pulsating waveform is controlled by another input waveform. The intersections between the reference
voltage waveform and the carrier waveform give the opening and closing times of the
switches.
PWM is commonly used in applications like motor speed control, converters, audio
amplifiers, etc. For example, it is used to reduce the total power delivered to a load without
losses, which normally occurs when a power source is limited by a resistive element.
PWM is used to adjust the voltage applied to the motor. Changing the duty ratio of the
switches changes the speed of the motor. The longer the pulse is closed compared to the
opened periods, the higher the power supplied to the load is. The change of state between
closing (ON) and opening (OFF) is rapid, so that the average power dissipation is very low
compared to the power being delivered. PWM amplifiers are more efficient and less bulky
than linear power amplifiers. In addition, linear amplifiers that deliver energy continuously
rather than through pulses have lower maximum power ratings than PWM amplifiers.
There is no single PWM method that is the best suited for all applications and with advances in solid-state power electronic devices and microprocessors, various pulse-widthmodulation (PWM) techniques have been developed for industrial applications. For these
reasons, the PWM techniques have been the subject of intensive research since 1970s.
1.2
Literature Review
With advances in solid-state power electronic devices and microprocessors, various inverter control techniques employing pulse-width-modulation (PWM) techniques are becoming increasingly popular in AC motor drive applications. These PWM-based drives are
used to control both the frequency and the magnitude of the voltages applied to motors [1].
Various PWM strategies, control schemes, and realization techniques have been developed
in the past two decades [2]. PWM strategy plays an important role in the minimization of
harmonics and switching losses in converters, especially in three-phase applications. The
first modulation techniques were developed in the mid-1960s by Kirnnich, Heinrick, and
Bowes as reported in [3]. The research in PWM schemes has intensified in the last few
decades. The main aim of any modulation technique is to obtain a variable output with a
maximum fundamental component and minimum harmonics [4].
The carrier-based PWM methods were developed first and were widely used in most
applications. One of the earliest modulation signals for carrier-based PWM is sinusoidal
PWM (SPWM). The SPWM technique is based on the comparison of a carrier signal and a
pure sinusoidal modulation signal. It was introduced by Schonung and Stemmler in 1964
as reported in [5]. The utilization rate of the DC voltage for traditional sinusoidal PWM is
only 78.5% of the DC bus voltage, which is far less than that of the six-step wave (100%).
Improving the utilization rate of the DC bus voltage has been a research focus in power
electronics [6].
This problem of the under-utilization of the DC bus voltage led to the development
of the third-harmonic-injection pulse-width modulation (THIPWM). In 1975, Buja developed this improved sinusoidal PWM technique, which added a third-order harmonic
content into the sinusoidal reference signal leading to a 15.5% increase in the utilization
rate of the DC bus voltage [6].
Another method of increasing the output voltage is the space-vector PWM (SVPWM)
3
technique. SVPWM was first introduced in the mid-1980s and was greatly advanced by
Van Der Broeck in 1988 [9]. Compared to THIPWM, the two techniques have similar results but their methods of implementation are completely different. With the development
of microprocessors, SVPWM has become one of the most important PWM methods for
three-phase inverters [7]. Many SVPWM schemes have been developed and extensively
investigated in the literature. The goal in each modulation strategy is to lower the switching
losses, maximize bus utilization, reduce harmonic content, and still achieve precise control
[8].
The SVPWM technique utilizes the DC bus voltage more efficiently and generates less
harmonic distortion when compared with the SPWM technique [4]. The maximum peak
fundamental magnitude of the SVPWM technique is about 90.6% of the inverter capacity.
This represents a 15.5% increase in the maximum voltage compared with conventional
sinusoidal modulation [10].
In 1991, Holtz proposed a classical over-modulation technique based on SVPWM,
which divided the over-modulation range into two modes of operation and increased the
utilization rate of the DC voltage to that of a six-step wave [6,11,12,13]. Holtz proposed this technique using switching time calculations in the over-modulation region of
SVPWM.
In 1998, Lee analyzed Holtzs over-modulation technique graphically, gave some approximate linear expressions between the modulation index and its own auxiliary parameter, and discussed the harmonic problem [14]. He showed that this technique generated
less harmonic distortion in the output voltages (or) the currents applied to the phases of
an AC motor and provided more efficient use of the DC input voltage. Because of its
superior performance characteristics, it has found widespread application in recent years
[4]. Accordingly, many other researchers have explored various aspects of this technique
in the literature [6,15,16,17].
1.3
Research Motivation
The SPWM technique is the easiest modulation scheme to understand and to implement
in software or hardware but this technique is unable to fully utilize the DC bus supply
voltage available to the voltage source inverter. This drawback led to the development of
THIPWM and SVPWM. THIPWM is a technique that adds a third-order harmonic content
to a sinusoidal reference signal thereby increasing the utilization rate of the DC bus voltage
by 15.5%.
The implementation of the conventional SVPWM is especially difficult because it
requires complicated mathematical operations. In the under-modulation region, this algorithm provides 15.5% higher output voltages compared to the SPWM technique. Moreover, the utilization of the DC bus voltage can be further increased when extending into
the over-modulation region of SVPWM.
Three-phase voltage source pulse-width modulation inverters have been widely used
for DC to AC power conversion since they can produce outputs with variable voltage
magnitude and variable frequency. For example, modern power electronics controllers
have been rapidly moving toward digital implementation. Typical solutions employ microcontrollers or DSPs [18].
This thesis discusses the principles, theories, mathematical equations, and procedures
involved for the software (MATLAB/Simulink package) implementation of these techniques. This thesis synthesizes and compares the main theories behind three-phase generation of SPWM, THIPWM, and SVPWM. These three techniques are used to generate their
respective output PWM signals, which are then compared based on harmonic content and
distortion using the total harmonic distortion (THD) measure of various output voltages.
1.4
Thesis Organization
CHAPTER 2
2.1
2.1.1
Sinusoidal PWM
Sinusoidal PWM Concept
The sinusoidal pulse-width modulation (SPWM) technique produces a sinusoidal waveform by filtering an output pulse waveform with varying width. A high switching frequency leads to a better filtered sinusoidal output waveform. The desired output voltage
is achieved by varying the frequency and amplitude of a reference or modulating voltage. The variations in the amplitude and frequency of the reference voltage change the
pulse-width patterns of the output voltage but keep the sinusoidal modulation.
As shown in Figure 2.1, a low-frequency sinusoidal modulating waveform is compared
with a high-frequency triangular waveform, which is called the carrier waveform. The
switching state is changed when the sine waveform intersects the triangular waveform.
The crossing positions determine the variable switching times between states.
In three-phase SPWM, a triangular voltage waveform (VT ) is compared with three
sinusoidal control voltages (Va , Vb , and Vc ), which are 120 out of phase with each other
and the relative levels of the waveforms are used to control the switching of the devices in
each phase leg of the inverter.
A six-step inverter is composed of six switches S1 through S6 with each phase output
connected to the middle of each inverter leg as shown in Figure 2.2. The output of the
comparators in Figure 2.1 form the control signals for the three legs of the inverter. Two
8
carrier voltage waveform. When the sinusoidal waveform is greater than the triangular
waveform, the upper switch is turned on and the lower switch is turned off. Similarly,
when the sinusoidal waveform is less than the triangular waveform, the upper switch is
off and the lower switch is on. Depending on the switching states, either the positive or
negative half DC bus voltage is applied to each phase. The switches are controlled in pairs
((S1 , S4 ), (S3 , S6 ), and (S5 , S2 )) and the logic for the switch control signals is:
S1 is ON when Va >VT
S4 is ON when Va <VT
S3 is ON when Vb >VT
S6 is ON when Vb <VT
S5 is ON when Vc >VT
S2 is ON when Vc <VT .
Figure 2.3: Three-Phase Sinusoidal PWM: a). Reference Voltages (a,b,c) and Triangular
Wave b). Vao , c) Vbo , d) Vco e) Line-to-Line Voltages [27].
9
As seen in Figure 2.3, the pulse widths depend on the intersection of the triangular and
sinusoidal waveforms. The inverter output voltages are determined as follows:
if
and if
Va >VT
then
Vao = 0.5Vdc
Vb >VT
then
Vbo = 0.5Vdc
Vc >VT
then
Vco = 0.5Vdc
Va <VT
then
Vao = 0.5Vdc
Vb <VT
then
Vbo = 0.5Vdc
Vc <VT
then
Vco = 0.5Vdc .
The inverter line-to-line voltages are obtained from the pole voltages as:
2.1.2
The Fourier series expansion of a symmetrical square wave voltage with a peak magnitude
of Vdc /2 has a fundamental of magnitude 2Vdc /. The maximum of the output voltage
generated by the SPWM method is Vdc /2. The modulation index is defined as the ratio of
the magnitude of output voltage generated by SPWM to the fundamental peak value of the
maximum square wave. Thus, the maximum modulation index of the SPWM technique is
MI =
VPW M
Vmaxsixstep
Vdc
2
2Vdc
0.7855 = 78.55%,
4
10
where VPW M is the maximum output voltage generated by a SPWM and Vmaxsixstep is the
fundamental peak value of a square wave.
2.2
2.2.1
Third-Harmonic-Injection PWM
Concept and Calculation of Optimum Distortion
The sinusoidal PWM is the simplest modulation scheme to understand but it is unable to
fully utilize the available DC bus supply voltage. Due to this problem, the third-harmonicinjection pulse-width modulation (THIPWM) technique was developed to improve the
inverter performance.
Following Reference [17], consider a waveform consisting of a fundamental component with the addition of a triple-frequency term:
y = sin + A sin 3 ,
(2.1)
(2.2)
cos = 0
and
(2.3)
11
cos =
9A 1
12A
1
2
(2.4)
sin = 1
(2.5)
and
sin =
1 + 3A
12A
1
2
(2.6)
The peak value of y can be found by substituting the values obtained for sin in (2.5) and
(2.6) into (2.1). Using the following trigonometric identity,
(2.7)
(2.8)
yb = 1 A
(2.9)
and
1 + 3A
yb = 8A
12A
where yb is the peak value of y.
3
2
(2.10)
12
The optimum value for A is that value which minimizes yb and can be found by differentiating (2.10) for yb with respect to A and equating the result to zero. Then, Equation
(2.10) becomes,
db
y
=
dA
1 + 3A
12A
1
2
1
2
= 0.
3A
(2.11)
A=
1
3
and
1
A= .
6
(2.12)
From Equation (2.9), we can see that the negative value of A makes yb greater than unity.
Therefore, the only valid solution for A is 1/6 and the required waveform is
1
y = sin + sin 3 .
6
(2.13)
From Equation (2.3), cos = 0 yields = /2. Substituting the value of 1/6 for A in (2.4)
gives cos = 1/2, i.e., = /3, 2/3, etc. All triple harmonics pass through zero at these
values of . If we substitute the values of = n/3 in (2.13), then we have a maximum
output waveform by a factor of 3/2 without changing the amplitude of the fundamental.
It is possible to increase the amplitude of the modulating waveform by a factor K, so
that the full output voltage range of the inverter is again utilized [17]. If the modulating
waveform is expressed as
1
y = K(sin + sin 3 ),
6
(2.14)
13
the required factor K for a peak value of unity should satisfy the constraint
1 = K 3/2
(2.15)
2
K= .
3
(2.16)
and, therefore,
On the same figure, we see that the addition of this third harmonic produces a 15.5%
increase in the amplitude of the fundamental of the phase voltages. Figure 2.4(a) does
not have a third harmonic, only a peak value and amplitude of fundamental equal 1. The
peak of Figure 2.4(b) is 3/2 with one-sixth of the third harmonic added. The amplitude
of the fundamental equals 1. The peak amplitude in Figure 2.4(c) equals 1 while the
peak amplitude of the fundamental equals 2/ 3 with one-sixth of third harmonic added.
Injecting a third harmonic component to the fundamental component gives the following
modulating waveforms for the three-phase [17]:
1
2
Van = sin(t) + sin(3t)
6
3
2
1
Vbn = sin(t 2/3) + sin(3t)
6
3
2
1
Vcn = sin(t + 2/3) + sin(3t) .
6
3
(2.17)
(2.18)
(2.19)
The THIPWM is implemented in the same manner as the SPWM, that is, the reference
waveforms are compared with a triangular waveform. As a result, the amplitude of the
reference waveforms do not exceed the DC supply voltage Vdc /2, but the fundamental
component is higher than the supply voltage Vdc . As mentioned above, this is approximately 15.5% higher in amplitude than the normal sinusoidal PWM. Consequently, it
14
15
Figure 2.5: Reference Voltages (a,b,c), Triangular Waveforms (VT ), and Output Voltage
(Vao ,Vbo ,Vco ).
16
CHAPTER 3
3.1
Introduction
Another method for increasing the output voltage about that of the SPWM technique is
the space vector PWM (SVPWM) technique. Compared to THIPWM, the two methods
have similar results but their methods of implementation are completely different. In the
SVPWM technique, the duty cycles are computed rather than derived through comparison
as in SPWM. The SVPWM technique can increase the fundamental component by up to
27.39% that of SPWM. The fundamental voltage can be increased up to a square wave
mode where a modulation index of unity is reached.
SVPWM is accomplished by rotating a reference vector around the state diagram,
which is composed of six basic non-zero vectors forming a hexagon. A circle can be
inscribed inside the state map and corresponds to sinusoidal operation. The area inside
the inscribed circle is called the linear modulation region or under-modulation region. As
seen in Figure 3.1, the area between the inside circle and outside circle of the hexagon
is called the nonlinear modulation region or over-modulation region. The concepts in the
operation of linear and nonlinear modulation regions depend on the modulation index,
which indirectly reflects on the inverter utilization capability.
17
Figure 3.1: Under-modulation and Over-modulation Regions in Space Vector Representation [12].
3.2
(3.1)
where Va (t), Vb (t), and Vc (t) are three sinusoidal voltages of the same amplitude and
frequency but with 120o phase shifts. The space vector at any given time maintains its
magnitude. As time increases, the angle of the space vector increases, causing the vector
to rotate with a frequency equal to that of the sinusoidal waveforms. When the output
18
voltages of a three-phase six-step inverter are converted to a space vector and plotted on
the complex plane, the corresponding space vector takes only on one of six discrete angles
as time increases. The central idea of SVWPM is to generate appropriate PWM signals so
that a vector with any desired angle can be generated.
SVPWM is a form of PWM proposed in the mid-1980s that is more efficient compared
to natural and regularly-sampled PWM. In the space-vector modulation, a three-phase
two-level inverter can be driven to eight switching states where the inverter has six active
states (1-6) and two zero states (0 and 7).
A typical two-level inverter has 6 power switches (labeled S1 to S6 ) that generate threephase voltage outputs. A detailed drawing of a three-phase bridge inverter is shown in
Figure 3.2. The circuit has a full-bridge topology with three inverter legs, each consisting
of two power switches. The circuit allows only positive power flow from the supply system
to the load via a full-bridge diode rectifier. Negative power flow is not possible through
the rectifier diode bridge.
The six switching power devices can be constructed using power BJTs, GTOs, IGBTs,
etc. The choice of switching devices is based on the desired operating power level,
required switching frequency, and acceptable inverter power losses. When an upper transistor is switched on, the corresponding lower transistor is switched off. Therefore, the
ON and OFF states of the upper transistors S1 , S3 , S5 can be used to determine the current
output voltage. The ON and OFF states of the lower power devices are complementary
to the upper ones. Two switches on the same leg cannot be closed or opened at the same
time.
The basic principle of SVPWM is based on the eight switch combinations of a threephase inverter. The switch combinations can be represented as binary codes that correspond to the top switches S1 , S3 , and S5 of the inverter as shown in Figure 3.2. Each
switching circuit generates three independent pole voltages Vao , Vbo , and Vco , which are
19
Equation (3.1), may be depicted as the space vector V (t) = 23 [Vdc e j0 ]. Repeating the
same procedure, we can find the remaining active and non-active states shown in Figure
3.3.
The three-phase inverter is therefore controlled by six switches and eight inverter
configurations. The eight inverter states can be transformed into eight corresponding space
vectors. In each configuration, the vector identification uses a 0 to represent the negative
phase voltage level and a 1 to represent the positive phase voltage level. The relationship
between the space vector and the corresponding switching states is given in Table 3.1
and Figure 3.2. In addition, the switches in one inverter branch are in controlled in a
complementary fashion (1 if the switch is on and 0 if it is off). Therefore,
20
2 Vdc e j(k1) 3
3
Vk=
if k = 1, 2, 3, 4, 5, 6
(3.2)
if k = 0, 7.
The entire space is divided into six equal-size sectors of 60o . Each sector is bounded
by two active vectors. V 0 and V 7 are two voltage vectors with zero amplitude located at
the origin of the hexagon. The eight active and non-active state vectors are geometrically
drawn in Figure 3.4.
21
Table 3.1: Space Vectors, Switching States, and On State Switches
Space Vetor
Swtiching State
On-state Switch
Vector Definition
V0
[000]
S4,S6,S2
V0=0
V1
[100]
S1,S6,S2
V 1 = 32 Vdc e j0
V2
[110]
S1,S3,S2
V 2 = 23 Vdc e j 3
V3
[010]
S4,S3,S2
V 3 = 32 Vdc e j 3
V4
[011]
S4,S3,S5
V 4 = 32 Vdc e j 3
V5
[001]
S4,S6,S5
V 5 = 32 Vdc e j 3
V6
[101]
S1,S6,S5
V 6 = 32 Vdc e j 3
V7
[111]
S1,S3,S5
V 7 = 32 Vdc e j0
zero vectors ( V 0 and V 7 ) and active vectors ( V 1 to V 6 ) do not move in space. They are
referred to as stationary vectors. Figure 3.4 shows the reference vector V re f in the first
sector.
The six active voltage space vectors are shown on the same graph with an equal
magnitude of 2Vdc /3 and a phase displacement of 60o . The inverter cannot produce a
desired reference voltage vector directly. It is possible to decompose the reference vector
into vectors that lie on two adjacent active vectors and two zero vectors, which are located
at the center of the hexagon.
The relationship between the switching variable vector [S1 , S3 , S5 ] and the line-to-line
22
voltage vector [Vab ,Vbc ,Vca ] is shown in Equation (3.1). When the upper or lower transistor
of a phase is ON, the switching signal of that phase is 1 or -1, and when an upper or
lower transistor is OFF, then the switching signal is 0. The eight combinations and the
derived output line-to-line and phase voltages in terms of the DC supply voltage are:
Vab
V
bc
Vca
1 1 0 S1
= Vdc 0
S
1
1
1 0
1
S5
(3.3)
Va0
= Van +Vn0
Vb0
= Vbn +Vn0
Vc0
= Vcn +Vn0
V +V +V
0.
an
cn =
bn
(3.4)
23
From Equations (3.3) and (3.4), the output phase voltages of the inverter depend on the
relationship between the switching variables [S1 , S3 , S5 ] and the DC voltage as follows:
Van
V
bn
Vcn
2 1 1 S1
Vdc
1 2 1 S .
=
3
1 1 2
S5
(3.5)
According to the Equations (3.3) to (3.5), the eight switching vectors, output line-toneutral voltage (phase voltages), and output line-to-line voltages in terms of DC link Vdc
are given in Table 3.2 along with the eight inverter voltage vectors ( V 0 to V 7 ).
Table 3.2: Vectors, Switching Vectors, Phase Voltages and Line to Line Voltages as a
Function of the DC Bus Voltage Vdc .
Voltage
Switching
Vectors
Vectors
Line-to-Neutral
Line-to-Line
Voltages
Voltages
Van
Vbn
Vcn
Vab
Vbc
Vca
V0
V1
2Vdc
3
V3dc
V3dc
Vdc
-Vdc
V2
Vdc
3
Vdc
3
2V3dc
Vdc
-Vdc
V3
V3dc
2Vdc
3
V3dc
-Vdc
Vdc
V4
2V3dc
Vdc
3
Vdc
3
-Vdc
Vdc
V5
V3dc
V3dc
2Vdc
3
-Vdc
Vdc
V6
Vdc
3
2V3dc
Vdc
3
Vdc
-Vdc
V7
The space vector can be also represented in another reference frame with two orthogonal axes ( and ). We assume that the axis is aligned in the horizontal direction
and that the axis is vertical. Then the abc three-phase voltage vector given in Equation
(3.1) can be transformed into a vector with coordinates. The vector is used to find
24
the sector of the plane in which the reference voltage vector lies. The phase voltages
corresponding to the eight combinations of switching patterns can be mapped into
coordinates:
2
2
2
(3.6)
2
2
2
2
2
2
V + jV = (Va +Vb cos( ) +Vc cos( )) + j (Vb sin( ) Vc cos( )).
3
3
3
3
3
3
Equating real and imaginary parts, we get
2
2
2
V = (Va +Vb cos( ) +Vc cos( ))
3
3
3
(3.7)
2
2
2
V = (Vb sin( ) Vc cos( )).
3
3
3
(3.8)
V re f
Va
V
1
1/2
1/2
V .
=
=
b
3 0 3/2 3/2
V
Vc
(3.9)
The values of V and V in Table 3.3 are called the and components of the space
vector, and the last column in Table 3.3 shows the reference space vector. The voltages V
and V become the inputs for dwelling time calculations in the space vector PWM and are
3.3
The SVPWM scheme is more complicated than that of the conventional SPWM. It requires the determination of a sector, calculation of vector segments, and it involves region
identification based on the modulation index and calculation of switching time durations.
25
Table 3.3: Voltage Vectors, Switching Vector, and
Voltage Vector
Vector
V0
V1
2Vdc
3
V0o
V2
Vdc
3
V
dc
3
V60o
V3
V3dc
V
dc
3
V120o
V4
2Vdc
3
V180o
V5
V3dc
Vdc3
V240o
V6
Vdc
3
Vdc3
V300o
V7
1. Calculate the angle and reference voltage vector V re f based on the input voltage
components.
2. Calculate the modulation index and determine if it is in the over-modulation region.
3. Find the sector in which V re f lies, and the adjacent space vectors of V k and V k+1
26
based on the sector angle .
4. Find the time intervals Ta and Tb and T0 based on Ts , and the angle . (For overmodulation, find Ta0 , Tb0 and T00 is zero.)
5. Determine the modulation times for the different switching states.
3.3.1
In the Space Vector PWM, the three-phase output voltage vector is represented by a
reference vector that rotates at an angular speed of = 2 f . The Space Vector PWM
reference voltage vector V re f that rotates with angular speed in the plane represents
three sinusoidal waveforms with angular frequency in the abc coordinate system. Each
output voltage combination in Table 3.3 corresponds to a different voltage space vector.
Three sinusoidal and balanced voltages are given by the relations:
(3.10)
(3.11)
(3.12)
For any three-phase system with three wires and equal load impedances, we have
(3.13)
The space vector with magnitude Vre f rotates in a circular direction at an angular velocity
of where the direction of rotation depends on the phase sequence of the voltages. If it
has a positive phase sequence, then it rotates in the counterclockwise direction. Otherwise,
it rotates in the clockwise direction with a negative phase sequence.
27
The three-phase voltages could be described with only two components, and , in a
two-dimensional plane. The magnitude of each active vector is 2Vdc /3. The active vectors
are 60o apart and describe a hexagon boundary. The locus of the circle projected by the
V re f =
[Va + aVb + a2Vc ]
3
where
(3.14)
| V re f | =
V2 +V2 .
(3.15)
where
3.3.2
V
),
V
(3.16)
[0,2].
In the linear region, the rotating reference vector always remains within the hexagon. The
largest output voltage magnitude is the radius of the largest circle that can be inscribed
within the hexagon. This means that the linear region ends when the reference voltage is
equal to the radius of the circle inscribed within the hexagon.
The fundamental component of the voltage waveform is shown in Figure 3.6. From a
Fourier analysis, the fundamental voltage magnitude is given by
28
Vmaxsixstep =
=
=
=
Z /3
Z /2
4
Vdc
2Vdc
sin d +
sin d
0
3
3
/3
i
4Vdc h
( cos + 1) + (2 cos + 2 cos
3
3
2
3
4Vdc h
i
1 + cos
3
3
2Vdc
.
(3.17)
The ratio between the reference vector V re f and the fundamental peak value of the square
MI =
V re f
Vmaxsixstep
(3.18)
From the geometry of Figure 3.1, the maximum modulation index is obtained when V re f
equals the radius of the inscribed circle.
2
(3.19)
29
Therefore,
MImax =
3.3.3
3 Vdc cos( 6 )
2Vdc
= 0.907.
(3.20)
Sector Determination
It is necessary to know in which sector the reference output lies in order to determine the
switching time and sequence. The identification of the sector where the reference vector
is located is straightforward. The phase voltages correspond to eight switching states: six
non-zero vectors and two zero vectors at the origin. Depending on the reference voltages
V and V , the angle of the reference vector can be used to determine the sector as per
Table 3.4.
Table 3.4: Sector Definition.
3.3.4
Sector
Degrees
0 < 60 o
60 < 120o
Time Durations Ta , Tb , T0
The duty cycle computation is done for each triangular sector formed by two state vectors.
The magnitude of each switching state vector is 2Vdc /3 and the magnitude of a vector
to the midpoint of the hexagon line from one vertex to another is Vdc / 3. In the undermodulation, the maximum possible modulation index is 0.907 as derived previously.
30
The reference space vector rotates and moves through different sectors of the complex
plane as time increases. In each PWM cycle, the reference vector V re f is sampled at
a fixed input sampling frequency fs . During this time, the sector is determined and the
modulation vector V re f is mapped onto two adjacent vectors. The non-zero vectors can
be represented by
V k = Vdc e j(k1) 3
3
(3.21)
for k=1, 2, 3, 4, 5, 6.
2
2
k
k
Ts
2
V re f dt =
T0
4
Z
0
V 0 dt +
T0
4 +Ta
T0
4
V k dt +
T0
4 +Ta +Tb
T0
4 +Ta
V k+1 dt +
Ts
2
T0
4 +Ta +Tb
V 7 dt (3.22)
can be carried out for only half of the pulse-width modulation period (Ts /2). Zero voltages
are applied during the null state times:
Z
0
T0
4
V 0 dt =
Ts
2
T0
4 +Ta +Tb
V 7 dt = 0.
(3.23)
Ts
2
V re f dt =
T0
4 +Ta
T0
4
V k dt +
T0
4 +Ta +Tb
T0
4 +Ta
V k+1 dt.
(3.24)
Thus, the product of the reference voltage vector V re f and Ts /2 equals the sum of the
31
voltage multiplied by the time interval of the chosen space vectors. The reference voltage
Ts
V re f = V k Ta + V k+1 Tb
2
V re f = V + jV ,
(3.25)
where Ta and Tb denote the required on-time of the active-state vectors V k and V k+1
during each sample period, and k is the sector number denoting the reference location.
The calculated times Ta and Tb are applied to the switches to produce space vector PWM
switching patterns based on each sector. The switching time is arranged according to the
first half of the switching period while the other half is a reflection forming a symmetrical
pattern (see Figure 3.7). T0 and T7 are the times of the null state vectors in Figure 3.7.
If V re f lies exactly in the middle between two vectors, for example between V 1 and
Assuming that the reference voltage and the voltage vectors V k and V k+1 are constant
during each pulse-width modulation period Ts and splitting the reference voltage V re f into
its real and imaginary components (V and V ) gives the following result:
cos (k1)
3
cos k
3
V Ts 2Vdc
+ Tb
Ta
=
(k1)
2
3
k
sin 3
sin 3
V
or
32
cos (k1)
3
cos k
3
Ta
= Vdc
.
3
k
sin (k1)
sin
T
b
3
3
(3.26)
These equations require computations involving trigonometric functions. From the Equation (3.26), the inverse matrix is used to calculate Ta and Tb as:
k
k
sin 3
cos 3 V
3Ts
Ta
=
(k1)
2Vdc
cos
sin (k1)
V
Tb
3
3
(3.27)
The Space Vector PWM produces the following balanced set of three-phase voltages with
Va = Vre f cos(t)
2
)
3
4
= Vre f cos(t ).
3
(3.28)
Vb = Vre f cos(t
(3.29)
Vc
(3.30)
(3.31)
k
k
sin 3
cos 3 cos nTs
3Ts | V re f |
Ta
.
(k1)
2Vdc
Tb
sin (k1)
cos
sin
nT
s
3
3
(3.32)
The modulation index is defined in Equation (3.18) as the ratio of the desired peak fundamental magnitude to the maximum fundamental output in a six-step mode:
33
MI =
| V re f |
Vmaxs ixstep
Vre f
2Vdc
(3.33)
or
2
| V re f | = MI Vdc .
(3.34)
Substituting this equation into the above equation for Ta and Tb leads to the following
duration times:
k
k
sin 3
cos 3 cos nTs
Ta MI 3Ts
.
(k1)
(k1)
Tb
cos 3
sin 3
sin nTs
(3.35)
Since the sum of 2Ta and 2Tb should be less than or equal to Ts , the inverter has to stay in a
zero state for the rest of the period. The duration of the null vectors is the remaining time
in the switching period. Since
Ts = T0 + 2(Ta + Tb )
(3.36)
T0 = Ts 2(Ta + Tb ).
(3.37)
The switching times are arranged symmetrical around the center of the switching
period as shown in Figure 3.7. The zero vector V 7 (1,1,1) is placed at the center of
the switching period, and the zero vector V 0 (0,0,0) at the start and the end, and the total
period for a zero vector is divided equally among the two zero vectors.
In the under-modulation region, as the modulation index increases, the reference voltage vector grows outward in magnitude. It reaches the inscribed circle of the hexagon and
T0 will reduce to zero whenever the tip of the reference voltage vector is on the hexagon. If
34
the modulation index increases further, then T0 becomes negative and meaningless. Therefore, the modulation index will reach a maximum of 0.907 in the linear under-modulation
region.
The calculated values of Ta and Tb in term of Ts /Vdc for all six sectors are listed in Table
3.5.
The time durations of two adjacent nonzero vectors in each sector are calculated
Table 3.5: Time Intervals Ta and Tb for Each Sector
Sector
0 < 60o
60 < 120o
Ta
Tb
3V
3V
4
4
3V
3V
4 + 4
3V
0V + 2
3V
3V
+
4
4
3V
3V
4 4
3V
0V 2
3V
2
3V
3V
4 + 4
3V
3V
4
4
3V
0V 2
3V
3V
4
4
3V
3V
4 + 4
0V +
based on the magnitude and phase of the reference voltage. From Figure 3.7, a zero state
vector is applied followed with two adjacent active vectors in half of the switching period.
The next half of the switching period is symmetrical to the first half.
To generate the signals that produce the rotating vector, an equation is required to
determine the time intervals for each sector. Figure 3.8 shows the pulse patterns generated
by space vector PWM in sector 1.
For example [19], when V re f is in sector 1 as shown in Figures 3.7 and 3.8, the V 1
vector is applied to the inverter during Ta interval, and consequently the vector V 2 is
applied during T2 interval. The PWM period is shared between V 1 and V 2 for durations
Ta and Tb , respectively, and the zero vectors V 0 and V 7 for a duration T0 . The switching
35
3.7 where it is assumed that the reference voltage is in the sector formed by vector V 1 and
V 2 with angle 0 < 60o . In Figure 3.7, switching states are required to change from
one state to the next. The progress of switching states from the left to the right of that
figure with following steps:
1. When the circuit configuration is in the V 0 state (time interval is T0 /2), all top
switches (S1 , S3 , and S5 ) of Figure 3.2 are opened.
3. When it is in the V 2 state (with a time interval Tb ), switch S3 is closed (S1 is still
closed).
4. When it is in the V 7 state (with a time interval T0 /2), switch S5 is closed. (S1 , and
S3 , are still closed.)
36
After the first half of the switching period is done, the switching combination is reversed. All switches are closed for T0 /2 seconds before the circuit configuration is back to
3.3.5
It is necessary to arrange the switching sequence so that the switching frequency of each
inverter leg is minimized. There are many switching patterns that can be used to implement
SVPWM. To minimize the switching losses, only two adjacent active vectors and two zero
vectors are used in a sector [15,20,21]. To meet this optimal condition, each switching
period starts with one zero vector and end with another zero vector during the sampling
time Ts . This rule applies normally to three-phase inverters as a switching sequence.
37
Therefore, the switching cycle of the output voltage is double the sampling time, and
the two output voltage waveforms become symmetrical during Ts . Table 3.6 presents a
symmetric switching sequence.
Referring to this table, the binary representations of two adjacent basic vectors differ in
only one bit, so that only one of the upper transistors switches is closed when the switching
pattern moves from one vector to an adjacent one. The two vectors are time-weighted in a
sample period Ts to produce the desired output voltage.
Table 3.6: Seven-Segment Switching Sequence
Sector
3.3.6
Switching Segment
1
~V0 ,[000]
~V1 ,[100]
~V2 ,[110]
~V7 ,[111]
~V2 ,[110]
~V1 ,[100]
~V0 , [000]
~V0 ,[000]
~V3 ,[010]
~V2 ,[110]
~V7 ,[111]
~V2 ,[110]
~V3 ,[010]
~V0 , [000]
~V0 ,[000]
~V3 ,[010]
~V4 ,[011]
~V7 ,[111]
~V4 ,[011]
~V3 ,[010]
~V0 , [000]
~V0 ,[000]
~V5 ,[001]
~V4 ,[011]
~V7 ,[111]
~V4 ,[011]
~V5 ,[001]
~V0 , [000]
~V0 ,[000]
~V5 ,[001]
~V6 ,[101]
~V7 ,[111]
~V6 ,[101]
~V5 ,[001]
~V0 , [000]
~V0 ,[000]
~V1 ,[100]
~V6 ,[101]
~V7 ,[111]
~V6 ,[101]
~V1 ,[100]
~V0 , [000]
There are two modes of operation available for the PWM waveform: symmetric and
asymmetric PWM. The pulse of an asymmetric edge aligned signal always has the same
side aligned with one end of each PWM period. On the other hand, the pulse of symmetric
signals is always symmetric with respect to the center of each PWM period. The symmetrical PWM signal is often preferred because it has been shown to have the lowest total
harmonic distortion (THD), and has been implemented in [22,23,24]. Output patterns for
each sector are based on a symmetrical sequence. There are different schemes in space
38
vector PWM and they are based on their repeating duty distribution. The seven-segment
technique is studied in this thesis and will be referred to as the symmetric technique.
Based on the equations for Ta , Tb , T0 , T7 , and according to the principle of symmetrical
PWM, the switching sequence in Table 3.7 is shown for the upper and lower switches.
Figure 3.10 shows the switching patterns of all six sectors in the circle. As shown in
the same figure, the space vector for a three-phase voltage source inverter is divided into
six sectors based on six fundamental vectors. Any voltage vector in this vector space can
be synthesized using two adjacent vectors. One switching period is depicted in the same
figure. In sector 1, for example, switching is achieved by applying a zero state vector
followed by two adjacent active state vectors in a half switching period. The next half of
the switching period is the mirror image of the first half.
In order to reduce the switching loss of the power components of the inverter, it
is required that at each time only one bridge arm is switched. After re-organizing the
switching sequences, a scheme with center-aligned pulses is obtained as shown in Figure
3.9.
The switching pulse patterns of six different sectors in Figure 3.11 are shown for the
upper and lower switches of a three-phase inverter. It is obvious that in the odd sector
the active state sequence is in ascending-descending order; whereas, it is in a descendingascending order in an even sector. For example:
V 7, V 7, V 2, V 1, V 0.
V 3, V 0.
Following the same procedure, we have the switching sequence summarized in Table 3.8
for all six sectors.
40
41
Table 3.7: Switching Pulse Pattern for the Three Phase for Each Sector
Sector
S1 = Ta + Tb + T0 /2
S4 = T0 /2
S3 = Tb + T0 /2
S6 = Ta + T0 /2
S5 = T0 /2
S2 = Ta + Tb + T0 /2
S1 = Ta + T0 /2
S4 = Tb + T0 /2
S3 = Ta + Tb + T0 /2
S6 = T0 /2
S5 = T0 /2
S2 = Ta + Tb + T0 /2
S1 = T0 /2
S4 = Ta + Tb + T0 /2
S3 = Ta + Tb + T0 /2
S6 = T0 /2
S5 = Tb + T0 /2
S2 = Ta + T0 /2
S1 = T0 /2
S4 = Ta + Tb + T0 /2
S3 = Ta + T0 /2
S6 = Tb + T0 /2
S5 = Ta + Tb + T0 /2
S2 = T0 /2
S1 = Tb + T0 /2
S4 = Ta + T0 /2
S3 = T0 /2
S6 = Ta + Tb + T0 /2
S5 = Ta + Tb + T0 /2
S2 = T0 /2
S1 = Ta + Tb + T0 /2
S4 = T0 /2
S3 = T0 /2
S6 = Ta + Tb + T0 /2
S5 = Ta + T0 /2
S2 = Tb + T0 /2
42
Sector
43
44
CHAPTER 4
4.1
Introduction
Full utilization of the DC bus voltage is important for achieving, for example, maximum
output torque under all operating conditions in AC machine drive applications. Overmodulation aims to extend the linear operation region of the SVPWM, which leads to a
better utilization of the DC bus voltage and enhances the power utilization of the voltage
source inverter. Several approaches to over-modulation have been proposed to extend the
linear region of SVPWM over the years. It is an advanced method and possibly the best
technique for variable frequency drive applications.
For SPWM, the highest possible peak phase fundamental voltage is 0.5Vdc . With
SVPWM, the peak phase fundamental voltage can be as high as 0.577Vdc during undermodulation when the reference vector makes a circular trajectory and it can be higher in
the nonlinear modulation region when the desired trajectory partly passes outside of the
hexagon.
The modulation index of the over-modulation region ranges from 0.907 up to 1 [11].
The over-modulation range can be considered as one region or it can be divided into two
regions (see Figure 4.1). In this thesis, the over-modulation region is considered as two
regions with two modes of operation depending on the modulation index values.
In mode 1, the actual voltage vector keeps the angular speed of a modified reference
vector constant, but its amplitude changes over time.
45
Figure 4.1: The Two Over-Modulation Regions in Space Vector Representation [12].
In mode 2, both the amplitude and angle of the modified reference vector are varied.
4.2
Over-Modulation Mode 1
The over-modulation region starts when the reference voltage exceeds the hexagon boundary, and the MI is larger than 0.907. The boundary between the under-modulation zone
and over-modulation region 1 starts when MI=0.907 and the boundary between the overmodulation region 1 and the over-modulation region 2 starts when MI=0.952. In region
1, the crossover angle (r ) is measured from a hexagon vertex to the intersection of the
compensated voltage vector trajectory with a hexagon side (see Figure 4.3). The crossover
angle decreases as the modulation index is increased until at the limit of region 1. It
depends on the value of the modulation index and varies between /6 at the beginning
of region 1 when MI=0.907 and 0o at the end of region 1 when MI =0.952 as shown in
Figure 4.2. When the crossover angle equals zero degrees, the reference vector is fully on
46
the hexagon. The fundamental peak value generated in this way voltage is about 95% of
the peak voltage of the square wave. This gives a modulation index of 0.952 [23].
Cross Angle vs. Modulation Index
30
25
20
15
10
0.91
0.915
0.92
0.925
0.93
0.935
Modulation Index
0.94
0.945
0.95
0.955
while the desired phase angle is not modified. It starts when the reference voltage V re f
crosses the hexagon at two points in each sector. Figure 4.3 shows two crossing points at
B and C. There is a loss of fundamental voltage in the region where the reference vector
exceeds the hexagon boundary of B-C. To compensate for that loss, the output voltage
must track the modified reference voltage V re f , where it must change to a larger radius.
This leads to a new reference voltage ( V 0re f ), which crosses the hexagon at an angle r .
The angle of the new reference vector is transmitted without any change.
The characteristic of the over-modulation mode 1 is that the voltage space vector moves
partially on the hexagon (along B-C) and partially on the circle providing a continuous operation. The output voltage waveform is approximated by linear segments on the hexagon
trajectory and by sinusoidal segments on the circular trajectory.
When the reference voltage vector is within the hexagon, near the outer corners of a
sector on curve length A-B in the same figure, it is on a circular trajectory with switching
times of Ta , Tb , and T0 as in the under-modulation mode, but with a modified reference
voltage.
During the nonlinear modulation, only the active vectors are taken into account while
47
the zero states are neglected. So, when V re f is on the hexagon, T00 =0, the switching times
must be calculated using the modified equations [10]:
Ta0
Tb0
Ta
Ts
=
2 T + Tb
a
Ts
Tb
=
.
2 Ta + Tb
(4.1)
(4.2)
When the original reference trajectory passes outside of the hexagon, the tip of the
reference vector is located in the area between the inside circle and the outside circle of
the hexagon. The Ta and Tb equations in linear space vector PWM yield a negative and
meaningless duration for the zero vectors. Whether the trajectory is inside the hexagon or
not can be easily recognized using the following explanation.
48
The magnitude of the new reference voltage is a function of the phase angle . If
the modulation index is above 0.907, the desired trajectory passes outside of the hexagon
and the interval time T0 is negative on the zero state vectors. In this case, the converter
exceeds its linear region of operation and enters the over-modulation region. Therefore,
the synthesized waveform becomes distorted.
If T00 is equal to zero, Ta0 and Tb0 should be reduced with an equal ratio so that their
sum should equal Ts . We need to use Equations (4.1) and (4.2) for Ta0 and Tb0 in the region
where the modified reference trajectory moves along the hexagon. The durations of the
active vectors during one switching period Ts are calculated using
Ta0
Tb0
3 cos( (k 1) 3 ) sin( (k 1) 3 )
Ts
=
2
3 cos( (k 1) 3 ) + sin( (k 1) 3 )
= Ts Ta0
T00 = 0,
(4.3)
(4.4)
(4.5)
where k is the sector number. Equation (4.3) to (4.5) are used to calculate the durations of
the active vectors for each sector. Table 5.1 shows those durations for each sector. Using
Table 4.1: The Time Intervals Ta0 and Tb0 for Each Sector
Sector
0 < 600
60 < 1200
Ta0
3V V
3V +V
3V +V
2V
2V
3V +V
3V +V
3V V
3V V
2V
2V
3V V
Tb0
2V
3V +V
3V +V
2V
3V V
3V +V
2V
3V V
3V V
2V
3V +V
3V V
49
Equation (3.22) in the under-modulation chapter, we can find the new reference voltage
space vector in the over-modulation region of mode 1:
Ts
(4.6)
0 Ts
V re f =
V k Ta + V k+1 Tb0
2
Ts
2
V re f =
V k Ta + V k+1 Tb
Ts
2(Ta + Tb )
Ts
0
V re f .
V re f =
2(Ta + Tb )
(4.7)
Then,
Referring to Figure 4.4, consider the trajectory of three voltage vectors rotating in a
complex plane (left-hand side) and the phase voltage waveform of an actual voltage reference vector transformed in a time domain (right-hand side), which is actually modulated
by the inverter [14]. The phase voltage waveform is divided into four segments and the
Figure 4.4: Trajectory of Reference Voltage Vector and Phase Voltage Waveform in Mode
1 [14].
50
voltage equations in each segment are expressed as follows [14]:
Vdc
tan ,
3
f1 =
( r ) > 0
6
( + r ) > ( r )
6
6
for
Vdc
f2 =
sin ,
for
3 cos( 6 r )
Vdc
f3 =
sin ,
for
( r ) > ( + r )
2
6
3 cos( 3 r )
Vdc
f4 =
sin ,
for
( ) > ( r ),
2
2
3 cos( 6 r )
(4.8)
where = t and is the angular velocity of the fundamental voltage reference vector.
The modification of the reference voltage vector is the same in all of the six sectors of
vector diagram, the relationship between the crossover angle (r ) and the new reference
voltage is given by:
(Vdc / 3)
.
cos( r ) =
6
( V 0re f )
(4.9)
By expanding those four segment equations with a Fourier series, the fundamental component of the phase voltage can be expressed as:
4
F(r ) =
Z
0
f1 sin d +
6 +
f2 sin d +
6 +
f3 sin d
f4 sin d (4.10)
.
This integral ranges from an angle of 0 to /2 as shown in the complex plane (right part)
of the same figure. We can obtain the value of Fourier series F(r ) with respect to the
angle r . Since F(r ) is the peak of the reference voltage,
F(r ) =
2
Vdc MI
(4.11)
51
MI =
F(r )
.
2
Vdc
(4.12)
The Fourier series F(r ) can be generated from a MATLAB script. The relationship
between MI and the angle r gives us the plot shown in Figure 4.2, which shows the
correlation between MI and the crossover angle r .
4.3
Over-Modulation Mode 2
At the end of mode 1, the component of the reference voltage changes to a piecewise
linear waveform. When the modulation index is higher than 0.952, the second region of
the over-modulation region algorithm is entered. Both the reference magnitude and the
phase angle have to be changed compared to the linear region. The modified reference
vector is held at a vertex of the hexagon in every sector for the rest of the switching period.
The angle for which the active switching state vector is held constant is called the holding
angle h . Figure 4.5 shows the holding angle in region 2 as a function of the modulation
index.
52
[11]. An expression for the modified angle h in Mode 2 can be given as
m =
0
h
/6h
if : 0 h
if : h < < (/3 h )
(4.13)
Figure 4.6: Angular Displacement of Reference and Actual Voltage Vectors in Mode 2
[12].
1. If the angle falls between zero and the holding angle (h ), the modified reference
voltage vector is held at a vertex, while the fundamental voltage vector is continu-
53
ously rotating.
2. If the angle range is from the holding angle to (/6-h ), the modified reference
vector moves along the hexagon, but lags the fundamental voltage vector.
3. When equals /6 exactly, the modified reference vector catches up with the
reference vector.
4. When < ( 3 h ), the modified reference vector speeds past it until = /3h .
5. In the last angle range (/3 > /3 h ), the modified reference voltage vector
has just arrived at the other vertex. It remains there until the reference voltage vector
has caught up with the modified reference voltage vector.
The modulation will gradually change to a six-step mode for h equal zero and generate a
square wave when the modulation index gets close to 1. The six-step mode is characterized
by a selection of the switching vector for one-sixth of the fundamental period. In this case,
the maximum possible inverter output voltage is generated. Mode 2 ends when the holding
angle is /6.
The voltage equations in the four segments (see Figure 4.7) are expressed as:
Vdc
f1 = . tan p , for
0 < ( h )
6
3
Vdc
, for
( h ) < ( + h )
f2 =
3
6
6
Vdc sin( p0 )
, for
( + h ) < ( h )
f3 =
0
6
2
3. cos( 3 p )
2Vdc
f4 =
, for
( h ) < )
3
2
2
(4.14)
where
p0
6 + h 0 + h
6
= p =
=
=
1 6 h 6
1 6 h
1 6 h
(4.15)
Equations (4.10) to (4.12) are then used to find the values of modulation index and Fourier
54
series F(h ) with respect to the holding angle. A relationship between MI and holding
angle gives us the plot shown in Figure 4.5 [14]. The modulation index increases from 0
to /6 as the holding angle increases from 0.955 to 1.
Figure 4.7: Trajectory of Reference Voltage Vector and Phase Voltage Waveform in Mode
2.
55
CHAPTER 5
SIMULATION RESULTS
5.1
Introduction
56
5.2
Sinusoidal PWM
SPWM is very popular and easy to implement using comparators. The SPWM simulink
system model is built in Figure 5.1. It has the following blocks: (1) Sinusoidal wave
generators, (2) High-frequency triangular wave generator, and (3) comparators.
The SPWM technique treats each modulating voltage as a separate entity that is compared to the common carrier triangular waveform. A three-phase voltage set (Va , Vb ,
and Vc ) of variable amplitude is compared in three separate comparators with a common
triangular carrier waveform of fixed amplitude as shown in the same figure. The output
(Vao , Vbo , and Vco ) of the comparators form the control signals for the three legs of the
inverter composed of the switch pairs (S1 , S4 ), (S3 , S6 ), and (S5 , S2 ), respectively. From
these switching signals and the DC bus voltage, PWM phase-to-neutral voltages (Van ,
Vbn , and Vcn ) are obtained. In the simulink model, the simulation is performed under the
following conditions:
57
Vdc = 300 V
Switching frequency = 1800 Hz
Inverter frequency = 60 Hz
Vre f = 150 V.
Van =
Vbn
Vcn
58
To visualize the actual results, filtering of the PWM waveforms is required. The lineto-neutral voltages Van , Vbn , and Vcn are shown after they have been passed through a
low-pass filter. As expected, magnitudes of the phase voltages (Van , Vbn , and Vcn ) are about
0.5Vdc . The output voltage waveforms show that the higher the switching frequencies, the
smoother the output voltage waveforms, as expected.
5.3
THIPWM
The THIPWM simulink system model is the same as that of the SPWM system except for
the modulating waveform voltages, which are generated by injected the third-harmonic
components as follows:
59
Figure 5.4: Neutral Voltages Van , Vbn , and Vcn of SPWM after Filtering.
2
1
Va = sin(t) + sin(3t)
6
3
2
1
Vb = sin(t 2/3) + sin(3t)
6
3
2
1
Vc = sin(t + 2/3) + sin(3t) .
6
3
Figure 5.5 shows the line-to-neutral voltages and Figure 5.6 shows the line-to-line
p
voltage of THIPWM. As expected, the magnitude of the phase voltage is about 300/ (3)
(Volts) and 300 (Volts) for line-to-line voltage, and the results show that THIPWM improves the fundamental voltages compared to SPWM.
5.4
A two-level three-phase inverter has eight possible inverter switching states that can gen
erate eight space vectors: six non-zero vectors ( V 1 to V 6 ) and two zero vectors ( V 0 and
V 7 ). These vectors are applied during the switching times Ta , Tb , and T0 . According to
the time duration equations in the chapter on under-modulation SVPWM, the average pole
voltage vector over one PWM period can be averaged using two adjacent vectors and the
null vectors.
60
200
150
Van
Vbn
Vcn
100
50
50
100
150
200
0.002
0.004
0.006
0.008
0.01
0.012
0.014
0.016
0.018
Figure 5.5: Neutral Voltages Van , Vbn , and Vcn of THIPWM after Filtering.
300
200
100
100
Vab
Vbc
Vca
200
300
0.002
0.004
0.006
0.008
0.01
0.012
0.014
0.016
0.018
Figure 5.6: Neutral Voltages Vab , Vbc , and Vca of THIPWM after Filtering.
61
To generate a rotating space vector with constant amplitude, the reference voltage
vector must be limited to the inscribed circle inside the hexagon. The simulation model
used to verify the under-modulation SVPWM scheme is shown in Figure 5.7 and it has
seven main subsystems or blocks, which are shown in detail in Figures 5.8-5.13.
1. The first block Figure 5.8 is used to generate three-phase sinusoidal input voltages
with variable frequency, amplitude, direction, and DC bus voltage. The three signals
are delayed by 120o from each other.
2. The three-phase abc voltages are then converted to two-phase voltages given in
the second block as:
1
1
2
Va Vb Vc
3
3
3
1
1
= Vb Vc .
3
3
V =
V
(5.1)
[0,2]
(5.2)
= tan1 (
and using Table 3.5, it can be used to identify the sector of the reference voltage as
shown in Figure 5.10.
The modulation index is entered in the first block. It is the ratio of the amplitude of
the output sinusoidal voltage to the maximum fundamental voltage.
Figure 5.7: Linear Modulation of SVPWM Simulation System. Diagrams for Blocks 1 to 7 are Shown in Figures 5.8 to 5.13.
62
63
Figure 5.8: Three-Phase Input Sinusoidal Voltages and Modulation Index are Detail for
Block 1 in Figure 5.7.
4. In the fourth block, the switching time calculator is used to calculate the timing of the
reference voltage vector. The inputs are the sector in which the voltage vector lies,
the modulation index, the sampling time period of switching frequency, and cos t,
and sin t. The duration time of the active and zero vectors are then calculated using
k
k
sin 3
cos 3 cos nTs
Ta MI 3Ts
=
.
(k1)
Tb
sin (k1)
cos
sin
nT
s
3
3
64
Figure 5.9: , Voltages and Modulation Index are Detail for Block 2 in Figure 5.7.
65
Figure 5.11: Switching Time Calculation is Detail for Block 4 in Figure 5.7.
Figure 5.12: Timing Signals and Triangular Waveform Details for Block 6 in Figure 5.7.
66
7. The seventh block is built to simulate a voltage source inverter (Figure 5.13).
As seen in Figure 5.14, the inputs for the sixth block are the output time signals from
Figure 5.13: Inverter Output Signals to Neutral Voltages is Detail for Block 7 in Figure
5.7.
the fourth block and the triangular waveform is output from the fifth block. Figure
5.15 shows the pole voltages Vao , Vbo , and Vco for Linear Modulation SVPWM. Due
to the relationship between the DC bus voltage and the switching states of the output
from the sixth block, we obtain the following PWM phase-to-neutral voltages:
Vdc
(2S1 S3 S5 )
3
Vdc
=
(S1 + 2S3 S5 )
3
Vdc
=
(S1 S3 + 2S5 )
3
Van =
Vbn
Vcn
The simulation of the under-modulation of SVPWM is performed under the following conditions:
67
x 10
Triangular Wave
Time Signal of phase A
Time Signal of phase B
Time Signal of phase C
0.002
0.004
0.006
0.008
0.01
0.012
0.014
0.016
0.018
Vdc = 300 V
Sampling time period = 1/1800 Sec
Inverter frequency = 60 Hz
Vre f =
300
V.
3
Figure 5.16 shows the output voltage waveforms obtained from the SVPWM strategy. The modulation waveform of the seven-segment SVPWM has a saddle shape
when passed through a low-pass filter (Figure 5.16) and its line-to-neutral voltages
are sine waveforms because of the under-modulation PWM region (Figure 5.17).
The maximum neutral voltages Van , Vbn , and Vcn in Figure 5.18 is Vdc / 3 (173.2
Volts).
68
Figure 5.15: Vao , Vbo , and Vco for Linear Modulation SVPWM.
5.5
In the over-modulation region 1, additional calculations are required to compute the reference space vector. As mentioned before, there is a loss of fundamental voltage in the
region where the reference vector exceeds the hexagon boundary. To compensate for this
loss, the reference vector amplitude is increased in the region where the reference vector
is inside the hexagon boundary. The magnitude of the reference vector is changed from
the reference voltage vector to a modified reference voltage vector. A modified reference
voltage trajectory proceeds partly on the hexagon and partly on the circle. When it remains
on the circular part, the switching time of Ta , Tb , and T0 are similar to the equations used
69
Figure 5.16: Vao , Vbo and Vco for Linear Modulation SVPWM after Filtering.
for under-modulation. When the reference voltage vector passes outside of the hexagon,
the value of T0 is negative and meaningless. This problem is overcome by rescaling the
duration times. Thus, T00 =0, and Ta0 and Tb0 are the new time intervals shown in Table 4.1.
The simulation system model of the over-modulation region 1 of SVPWM is the same
as that of the under-modulation SVPWM system except for the lookup table in first block
and an added fourth block. The lookup table in the first block is the relationship between
MI and the crossover angle, which is shown in Figure 4.2. For an added fourth block, the
switches will be changed based on the duration T0 of the zero state vectors.
70
300
Vab
Vbc
Vca
200
100
100
200
300
0.002
0.004
0.006
0.008
0.01
0.012
0.014
0.016
0.018
150
100
50
0
50
100
150
200
0.002
0.004
0.006
0.008
0.01
0.012
0.014
0.016
0.018
Figure 5.18: Neutral Voltages Van , Vbn , and Vcn of Linear Modulation SVPWM after
Filtering.
When T0 is greater than zero, the duration times T0 , Ta , and Tb shown in Table 3.5
are used.
When T0 is less than zero, the active duration times become Ta0 and Tb0 , as shown in
71
Table 4.1.
Figure 5.19 shows the lookup table in the first block. Figure 5.20 shows the additional
Figure 5.19: Detail of the Lookup Table in the First Block of SPVWM Over-Modulation
Region 1.
block, which is a judgment condition for the over-modulation based on the sign of T0 . In
red circle, if T0 is negative, then Ta0 and Tb0 are used in the blue block.
As mentioned before, in the over-modulation region 1, the magnitude of the reference
voltage vector is changed while the angle remains unchanged. This region ends when the
reference voltage is traveling along the sides of the hexagon. The simulation results are
72
Figure 5.20: Detail of the Fourth Block of Space Vector PWM in Region 1.
presented to verify the effectiveness of this analysis. Figure 5.21 shows the output voltages
for region 1 of the over-modulation.
Compared to Figure 5.16, the phase voltage waveforms of Figure 5.21 do not have the
saddle waveform shape seen in the under-modulation SVPWM, but they stay at the limit
of the hexagon.
Figure 5.22 shows the neutral voltages Van , Vbn , and Vcn in region 1 of the overmodulation SVPWM after filtering. The voltage waveforms are no longer pure sine waveforms. Since the desired trajectory passes outside of the hexagon, the converter exceeds
its linear region of operation and enters the over-modulation region. Therefore, the synthesized waveforms become distorted.
The low pass filter removes the high-frequency switching components, leaving the
triple order harmonics in the phase voltage waveforms. These harmonics do not affect
the line-to-line voltages [1]. As shown in Figure 5.23, the waveforms of the line-to-line
voltages Vab , Vbc , and Vca are less distorted compared to the neutral voltages in Figure 5.22.
73
Figure 5.21: Vao , Vbo , and Vco of Over-Modulation Region 1 before and after Filtering.
74
400
Vab
Vca
Vbc
300
200
100
100
200
300
400
0
0.002
0.004
0.006
0.008
0.01
0.012
0.014
0.016
0.018
75
CHAPTER 6
6.1
Simulation Results
The simulation studies of Chapter 5 confirmed that the THIPWM and SVPWM techniques
have a better DC bus voltage utilization than SPWM. As seen in Figure 6.1, the smaller
circle represents the operating region of the SPWM technique and the larger inscribed
circle represents the operating region of the SVPWM technique in the under-modulation
region. In SVPWM, the length of each discrete space vector V 1 through V 6 is 2Vdc /3.
Each side of the hexagon midpoint is tangential to the inscribed circle. The largest possible
magnitude of the reference voltage can be calculated as
2Vdc
3 Vdc
MO = OL cos( ) =
= .
6
3
2
3
(6.1)
Vdc
3 Vdc
ON = OM cos( ) =
=
.
6
2
2
3
(6.2)
Thus, for SPWM, the smaller circle has a maximum magnitude of Vdc /2. It was already mentioned in Chapter 3 that the linear under-modulation region has a modulation
= (2/3)V
index that approaches 90.7% for a maximum output fundamental of Vmax
dc
76
cos(/6) = Vdc / 3. The line-to-line voltage magnitude in linear SVPWM is thus equal
to Vdc .
In SPWM, the maximum modulation index is 78.55%, the maximum output funda
mental is 0.5 Vdc , and the maximum amplitude of the line-to-line voltage is 3Vdc /2. The
line-to-line voltage of SVPWM is then increased by about:
3Vdc
2
3Vdc
2
Vdc
100 15.5%.
(6.3)
Figure 6.1: Locus Comparison of Maximum Peak Voltage in SPWM and SVPWM [28].
From the simulation studies, the diagram in Figure 6.2 shows the evolution of the
voltage reference vector V Re f in the complex plane. The space voltage vector, which
rotates with constant length and constant circular frequency, has the same features as
that of a line-to-neutral phase voltage. The rotating space voltage vector is inside the
77
hexagon for under-modulation and between the inscribed circle of the hexagon and the
circumscribed circle of the hexagon for over-modulation.
Figure 6.3 shows the locus of SPWM from the simulation results. When V re f is
desired to produce a balanced set of three-phase sinusoidal voltages, then the locus of
V re f is a circle inscribed inside the hexagon (Figure 6.4) when these space vectors are
plotted on real and imaginary axes.
Figure 6.5 shows the maximum circle loci of THIPWM and under-modulation of
SVPWM. They have the same radius.
In Figures 6.6 and 6.7, the locus of the space vector applied is partly circular and partly
hexagonal. In the hexagon portion, only two active states are applied. The simulated
78
200
150
100
50
50
100
150
200
200
150
100
50
50
100
150
200
results show that the over-modulation region 1 reported a modulation index that can reach
to 0.952. This is an extension of about 5%, which is a significant improvement.
79
6.2
In this section, the four different PWM techniques (SPWM, THIPWM, SVPWM in linear
modulation range, and SVPWM in over-modulation range 1) are compared in terms of
total harmonic distortion (THD). A Fast Fourier Transform (FFT) analysis in MATLAB is
used to conduct the harmonic analysis. The harmonic spectrum of the inverter voltage
waveforms of these techniques are presented with different modulation indices. The
frequency modulation ratio in this analysis is 30 using a modulation frequency of 60
Hz and a carrier frequency of 1800 Hz. The results shown in tables and figures below
include the first 50 harmonics. The sidebands frequency are positioned on both sides of
the carrier frequencies with a frequency separation of fo , where fo is the frequency of
80
200
150
100
50
50
100
150
200
200
150
100
50
50
100
150
200
200
150
100
50
50
100
150
200
200
150
100
50
50
100
150
200
81
formula: fc fo , where fc is carrier frequency.
h28
h30
42.73 101.34
47.69 90.19
h32
h34
42.7 2.06
47.67 2.66
Figure 6.7 and Table 6.1 show the harmonic results for the pole voltage Vao in the
SPWM technique. As expected, we do not see a third harmonic in SPWM. Comparing
the data of two different modulation indices in Table 6.1, we conclude that the higher
modulation index has a lower THD (%).
Figure 6.8 and Table 6.2 show the harmonic results of the THIPWM technique. This
technique has clearly increased the output voltage of the inverter compared to the SPWM
technique. Thus, the third harmonics is presented and has increased phase and line-to-line
voltages as well. As expected, the value of third harmonic in the Vao is about one-sixth
that of the fundamental voltage.
82
Fund
300.08
173.3
173.2
h3
h26
h28
1 37.56 71.42
1 21.68 41.22
28.74 21.68 41.21
h30
h32
h34
1 71.42 37.49
1 41.18 21.66
56.21 41.18 21.67
Voltages
Vab
Van
Vao
Compared to SPWM, the values in 26th and 34th harmonic of THIPWM are very high
and THD of THIPWM is significantly lower than for SPWM. The values of the 24th , and
36th harmonics are less than 5 Volts.
Table 6.3: Harmonics of Vao in Under-Modulation range of SVPWM
MI
0.733
0.7854
0.806
0.9069
h3
28.56
30.61
31.41
35.37
h26
h28
18.25 25.9
20.48 29.03
21.40 30.30
25.74 36.38
h30
95.73
83.53
78.53
54.06
h32
25.43
28.57
29.84
35.97
h34
17.63
19.85
20.76
25.11
Figure 6.9 and Table 6.3 show the harmonic results of Vao in the under-modulation
83
Fund
h3
h26
h28
177.9 37.52 24.82 35.92
181.8 39.35 24.83 36.06
30
h32
h34
47.02 37.63 27.53
41.08 37.74 27.51
84
85
Table 6.5: Vab in the SPWM
MI
0.733
0.7854
THD(%)
75.32
68.09
Fnd
242.50
259.77
h26 h28
3.58 73.97
4.64 82.57
h32 h34
73.99 3.57
82.58 4.6
THD(%)
75.32
68.09
Fnd
140.01
149.98
h26 h28
2.07 42.71
2.68 47.67
h32 h34
42.71 2.06
47.68 2.66
THD (%)
Fnd
73.3
242
66.01
259.3
63.14
266.24
49.54
300
h26
31.49
35.24
36.89
44.38
h28
45.06
50.50
52.70
63.28
h32
43.93
49.36
51.58
62.21
h34
30.60
34.44
36.01
43.56
THD (%)
Fnd
73.29
139.7
66
149.72
63.13
153.72
49.51
172.9
h26
18.52
20.49
21.39
25.74
h28
25.88
29.01
30.29
36.37
h32
25.44
28.58
29.86
35.97
h34
17.62
19.84
20.74
25.10
THD(%) Fnd
47.86
308
44.78
315
h26
h28
h32
h34
42.97 62.45 65.18 47.56
42.95 62.75 65.45 47.54
Fnd
h26
h28
178 24.97 35.86
182.1 24.95 36.01
h32
h34
37.47 27.60
37.61 27.56
86
CHAPTER 7
7.1
Conclusion
This thesis has evaluated three different PWM techniques, namely SPWM, THIPWM, and
SVPWM (in the linear modulation region and over-modulation mode 1). The contributions
of the thesis are as follows:
The thesis has provided a thorough review of the each techniques with a special
focus on the operation of SVPWM in the under-modulation and over-modulation
modes.
In this thesis, Simulink models for all three techniques have been developed and
tested in the MATLAB/Simulink environment. The SVPWM model is able to generate both the operation of the under-modulation region of SVPWM as well as the
over-modulation region 1.
The thesis discusses the advantages and drawbacks of each technique. Their simulation results are compared and analyzed by plotting the output harmonic spectra of
various output voltages, and computing their total harmonic distortion (THD).
As seen from the simulation results, SVPWM and THIPWM have a superior performance
compared to SPWM, especially in the over-modulation region of SVPWM. The SPWM
technique is very popular for industrial converters. It is the easiest modulation scheme to
understand and implement. This technique can be used in single-phase and three-phase
87
inverters.
The THIPWM technique operates by adding a third harmonic component to the sinusoidal modulating wave. It is possible to increase the fundamental by about 15.5% and,
hence, allow a better utilization of the DC power supply. From the shape of the line-to-line
voltages, the resulting flat-topped waveforms allow over-modulation with respect to the
original SPWM technique.
The SVPWM technique can only be applied to a three-phase inverter and it increases
the overall system efficiency. The SVPWM is used for controlling the switching of the
machine side converter. Advantages of this method include a higher modulation index,
lower switching losses, and less harmonic distortion compared to SPWM [27]. SVPWM
research has been widespread in recent years making it one of the most popular methods
for three-phase inverters because it has a higher fundamental voltage output than SPWM
for the same DC bus voltage. The SVPWM is significantly better than SPWM by approximately 15.5%. However, the SVPWM technique is complex in implementation, especially
in the over-modulation region.
The SVPWM technique has been deeply studied in the over-modulation region due
to its performance benefits when compared to other modulation techniques. Numerous
over-modulation algorithms have been proposed in the literature for the control of voltage
source inverters [14,12,24]. The simulated results confirm that the over-modulation region
1 leads to a modulation index up to 0.952. This is an extension of around 5%, which is a
significant improvement.
7.2
88
with neural networks and The Neural Network toolbox of MATLAB. Neural network implementation is very fast and can increase the switching frequency of power
switches in the inverter.
Many papers in the literature have reported that the dead time of space vector PWM
has an influence on drive systems. To circumvent this problem, it is important
to research how to compensate for the dead time effect in order to increase the
performance of drive systems.
89
REFERENCES
90
[12] J. Holtz, W. Lotzkat, and A.M. Khambadkone, On Continuous Control of PWM
Inverters in the Over-modulation Range Including the Six-Step Mode, IEEE Transactions on Power Electronics, Vol. 8, No. 4, pp. 546-553, October 1993.
[13] J. Holtz, On Continuous Control of PWM Inverters in Over-modulation Range
Including the Six-Step, IEEE Transactions on Power Electronics, Vol. 8, No. 4,
pp. 546-553, 1993.
[14] D.C. Lee, A Novel Over-modulation Technique for Space Vector PWM inverters,
IEEE Transactions on Power Electronics, Vol. 13, No. 6, pp. 1144-1151, Nov. 1998.
[15] D.G. Holmes and T.A. Lipo. Pulse Width Modulation for Power Converters. John
Wiley & Sons, Inc. 2003.
[16] A.M. Khambadkone, and J. Holtz, Current Control in Over-modulation Range for
Space Vector Modulation based Vector Controlled Induction Motor Drives, IEEE
Industrial Electronics Society, Vol.2, pp. 1134-1339, 2000.
[17] J.A. Houldsworth, and D.A. Grant, The Use of Harmonic Distortion to Increase the
Output Voltage of a Three-Phase PWM Inverter, IEEE Transactions on Industry
Applications, Vol. IA-20, No. 5, pp. 1124-1228, September-October 1984.
[18] M. Giesselmann, H. Salehfar, H.A. Toliyat, and T.U. Rahman, Modulation Strategies, CRC Press LLC, 2002.
[19] A. Savulescu, The Analysis and The Simulation of The SVM Generator Used
for The Control of The Electric Drives with Asynchronous Motors, International
Conference on Electromechanical and Power Systems, pp. 47-50, October 4-6, 2007.
[20] E. Hendawi, F. Khater, and A. Shaltout, Analysis, Simulation and Implementation
of Space Vector Pulse Width Modulation Inverter, International Conference on
Application of Electrical Engineering, pp. 124-131, 2010.
[21] B. Wu. High-Power Converters and AC Drives. IEEE Press, John Wiley and Sons,
Inc., 2006.
[22] MathWorks, 2010, SimPowerSystems, Users Guide.
[23] R.
Cordero,
and
J.O.P.
Pinto,
Relationship
Between
SPWM
and
SVPWM
for
Undermodulation
and
Overmodulation
Modes
Based
on
Modified
Carrier
Signal. Available
from:
http://www.labplan.ufsc.br/congressos/Induscon%202010/fscommand/
web/docs/I0275.pdf
[24] V.H. Prasad D. Boroyevich and R. Zhang, Analysis and Comparison of Space Vector
Modulation Schemes for Three-Leg and Four Leg Voltage Source Inverters, IEEE
Applied Power Electronics Conference and Exposition, Vol. 2, pp. 864-871, February
1997.
91
[25] A. Oteafy, How to Use a Sample & Hold Block after sector, duration time switching, Personal Communication.
[26] H. Patangia and D. Gregory, A Harmonic Reduction Scheme in SPWM, IEEE
Asia Pacific Conference on Circuits and Systems, pp. 1737-1740, 2006.
[27] C.U. Ogbuka and M.U. Agu, A Generalized Rectified Sinusoidal PWM Technique
for Harmonic Elimination, The Pacific Journal of Science and Technology, Vol. 10,
No. 2, pp. 21-26, November 2009.
[28] Texas Instruments Europe, Field Orientated Control of 3-Phase AC-Motors, Texas