Traco Power DC - DC Converter

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3
At a glance
Powered by AI
The document discusses DC/DC converters of the THP-3 series for applications requiring high isolation.

The input specifications include start-up voltage, recommended input fuse, surge voltage and input filter requirements.

The output specifications include voltage set accuracy, regulation, ripple and noise, temperature coefficient and current limitation.

DC/DC Converter

THP 3 Series

3 Watt
High Isolation

Features
I/O-Isolation Voltage of 4000VAC
Clearance and Creeping Distances min. 2.0mm
Basic-, Supplementary- and Reinforced Insulation
for Working Voltages up to 420VDC / 300VAC
Ultra wide 4:1 Input Ranges:
9-40VDC,18-80VDC and 36-160VDC
Extended Operating Temp. Range 40C to 85C
Input Filter meets EN55022A without ext.
Components
Continuous Short Circuit Protection
High Reliability, MTBF>1 Mio. Hours
3 Year Product Warranty

The THP-3 series is a new range of high performance 3W DC/DC converters in a low profile DIL-24 package with standard industry pin-out.
The very high I/O-isolation system of these converters and input voltages
up to 160 VDC make this product the best choice for many demanding
applications in railroad and transportation systems, medical equipment,
instrumentation, everywhere where high basic-, supplementary- or reinforced insulation is requested to meet specific safety standards. A high
efficiency allows safe operation in a temperature range of 40C to +85C
at full load without derating. Full SMD-design with exclusive use of ceramic capacitors ensure a very high reliability and a long product lifetime.

Models
Ordercode
THP 3-2411
THP 3-2412
THP 3-2422
THP 3-2423
THP 3-4811
THP 3-4812
THP 3-4822
THP 3-4823
THP 3-7211
THP 3-7212
THP 3-7222
THP 3-7223

www.tracopower.com

Input voltage

Output voltage

Output current max.

Efficiency typ.

9 40 VDC

5
12
12
15

VDC
VDC
VDC
VDC

600 mA
250 mA
125 mA
100 mA

78
83
83
83

%
%
%
%

18 80 VDC

5
12
12
15

VDC
VDC
VDC
VDC

600 mA
250 mA
125 mA
100 mA

78
83
83
83

%
%
%
%

36 160 VDC

5
12
12
15

VDC
VDC
VDC
VDC

600 mA
250 mA
125 mA
100 mA

78
83
83
83

%
%
%
%

Page 1

DC/DC Converter
THP 3 Series

3 Watt

Input Specifications
Input current at no load / full load

24 Vin models:
48 Vin models:
72 Vin models:

20 mA typ. / 160 mA typ.


10 mA typ. / 80 mA typ.
5 mA typ. / 35 mA typ.

Start-up voltage /
under voltage shut down

24 Vin models:
48 Vin models:
72 Vin models:

8.5 VDC / 8.5 VDC (typ.)


15 VDC / 16 VDC (typ.)
30 VDC / 32 VDC (typ.)

Recommanded input fuse (slow blow)

24 Vin models:
48 Vin models:
72 Vin models:

1.0 A
0.5 A
0.3 A

Surge voltage (1 sec. max.)

24 Vin models:
48 Vin models:
72 Vin models:

50 V max.
100 V max.
180 V max.

Input filter

EN 55022, level A (without external components)

Output Specifications
Voltage set accuracy

1%

Voltage balance (dual output models)

2 % max.

Regulation

0.5 % max.
1.0 % max.

Input variation Vin min. to Vin max.


Load variation 25 100 %:

Ripple and noise (20 MHz Bandwidth)

100 mVpk-pk typ.

Temperature coefficient

0.02 % / C typ.

Current limitation

> 120 % Iout max.

Short circuit protection

indefinite (automatic recovery)

Capacitive load

5 VDC output models:


12 VDC output models:
Dual output models:

1000 F max.
470 F max.
220 F max. (each output)

Isolation /Safety
Isolation test voltage (1 sec.)

5700 VDC

I/O isolation voltage (50Hz, 60sec)

4000 VAC

I/O clearance and creepage

2.0mm min.

Leakage current

2 A (at 240VAC, 60Hz)

Isolation capacity

input/output

7 pF typ. (at 100KHz, 1V)

Isolation resistance

input/output

>1000 Mohm (at 500VDC)

Safety standards

IEC/EN 60950, UL 60950-1


CSA C22.2 No. 60950-1-03
IEC/EN 60601-1, EN 50124-1&2
UL 60601-1, CSA C22.2 No. 601-1

Safety approvals

CB-report, CSA File No. 226037

All specifications valid at nominal input voltage, full load and +25C after warm-up time unless otherwise stated.
www.tracopower.com

Page 2

DC/DC Converter
THP 3 Series

3 Watt

General Specifications
Temperature ranges

40 C ... +85 C
+ 95 C max.
40 C ... +125 C

Operating
Case
Storage

Derating

4 % /K above 75C

Humidity (non condensing)

95 % rel H max.

Reliability, calculated MTBF (MIL-HDBK-217 F)

>1 Mio. h @ 25 C, ground benign

Switching frequency

150 kHz typ. (puls width modulation)

Case material

non conductive plastic (UL 94V-0-rated)

Potting material

Silicon TSE 3331 (UL 94V-0-rated)

Weight

16.2 g (0.57 oz)

Soldering temperature

max. 260C / 10 sec

(0.1)

2.54

2. 0

(0.08)

Outline Dimensions

Pin-Out
1

Bottom view

20.32

(0.8)

15

(0.1)

2.54

(1.1)

27.9 4

32

(1.25)

24
23

11
12

(0.1)

2.54

13

10

(0.16)

(0.4)

2.4

15 .24

(0.1)

(0.6)

Pin

Single

Dual

+Vin (Vcc)

+Vin (Vcc)

11

No pin

Common

12

Vout

No pin

13

+Vout

Vout

15

No pin

+Vout

23

Vin (GND)

Vin (GND)

24

Vin (GND)

Vin (GND)

20
(0.79)

Dimensions in mm, ( ) = inches


Pin diameter: 0.6 mm 0.05 (0.024 0.002)
Tolerances: 0.25mm ( 0.01)
Specifications can be changed without notice
Rev. 10/04

Jenatschstrasse 1 CH-8002 Zurich Switzerland


Tel. +41-43311 4511 Fax +41-43311 4545 [email protected] www.tracopower.com

Page 3