Brosur & Spec - Carina System PDF

Download as pdf or txt
Download as pdf or txt
You are on page 1of 8

MT-0569-2008

Flexible and compact NIV ventilator


The road to recovery

DRGER CARINA

The road to

MT-0564-2008

MT--3940-2007

recovery

Non Invasive Ventilation (NIV) can


generally help patients recover faster,
reduce the rate of ventilator-associated
pneumonia and avoid the setback of
reintubation in a variety of clinical
settings. Patient benefit has been clearly
demonstrated in a growing number of
studies [1]:
Reduce the need for intubation and
therapeutic intervention in patients
with acute respiratory failure [2]
Decrease the rate of intubation [3]
Fewer complications during
ICU stay [3]
Promote early extubation [3]
Reduce the risk of ventilator
associated pneumonia [4]

Drger has developed an innovative type


of high-performance NIV ventilator. One
that is comfortable for both the patient and
the caregiver, compact and mobile enough
to optimize workflow and workspace
usage and clever enough to recognize
changes in flow parameters and patient
status, providing just the right amount of
support while giving the patient room to
breathe.
Carina features a range of ventilation
modes for spontaneous and mandatory
ventilation and an integrated blender which
can supply oxygen concentrations from
21 - 100%. Should the need arise, Carina
can even be used for invasive ventilation.

Spontaneous ventilation:
SPN-PS (+ Volume Guarantee)
SPN -CPAP
Mandatory ventilation:
VC-SIMV Autoflow
PC-BIPAP
PC-AC

1 Burns KEA, Adhikari NKJ, Meade MO:


Noninvasive positive pressure ventilation as
a weaning strategy for intubated adults with
respiratory failure. Cochrane Database of
Systematic Reviews 2003
2 Honrubia T, Lpez FJG, Franco N, et al.:
Noninvasive vs. conventional mechanical
ventilation in acute respiratory failure:
A multicenter randomized controlled trial.
Chest 2005; 128:3916-3924
3 Masip J, Roque M, Snchez B, et al. Noninvasive
ventilation in acute cardiogenic pulmonary
edema: systematic review and meta-analysis.
JAMA. 2005; 294:3124-3130
4 Girou E, Schortgen F, Delclaux C, et al.
Association of noninvasive ventilation with
nosocomial infections and survival in critically
ill patients. JAMA 2000; 284: 23612367

Leaks are a common issue in NIV.


Rapid recognition of leaks can mean the
difference between success and setback.
The unique Drger SyncPlus functionality
addresses this challenge by offering:
1. Automatic leakage compensation.
2. Cycle learning technology:
the trigger sensitivity is constantly
adapted to the patients breathing
patterns
3. Multi-sense triggering by closely
analyzing flow, pressures and
flow gradient
This powerful combination of leak evaluation and ventilation regulation supports
a more consistent flow, increased patient
comfort and therapeutic benefit.

MT-4091-2008

MT-8214-2005

MT-8221-2005

CLEVER

COMFORTABLE

Carinas AutoRamp feature simulates


a natural breathing pattern which helps to
optimize inflation flow delivery to the
patient. While the innovative Auto-Flow
function brings the benefits of the
Room to breathe concept to all
volume controlled modes. Therefore,
Carina constantly promotes the weaning
process by adapting itself to patients
responses.

Carina was designed with the comfort


of both patients and caregivers in mind.
To help promote a restful and healing
environment for your patients, Carina
features an extremely quiet blower that
enables practically silent operation (max.
40 dBA).
A 5.4 inch, high-visibility TFT color screen
displays your choice of value or curve
information which can be further
customized to suit your particular needs,
giving you just the information you need.
Comfort means also a variety of safety
features as: Apnea-, rescue- and
continuous ventilation fail-safe systems,
visible and acoustic alarms and a nurse
call function.

Carina
clever, comfortable, compact

MT-0583-2007

NovaStar NIV Full-Face Mask


Ultimate comfort and effective seal through customized
fit and silicone-gel cushion: NovaStar NIV full-face mask
is designed for non-invasive ventilation therapy. Because
the mask covers the nose and mouth, it provides effective
therapy, even in case of mouth breathing.

MT-0583-2007

COMPACT

MT-0487-2007

Weighing in at just 5.5 kg, Carinas


compact design lets you take it nearly
anywhere, with or without its detachable
trolley. An internal battery can provide
power for up to one hour while an
optional external battery unit can extend
this operation for up to 9 hours in case of
power failure or transfer. The single hose
system underscores Carinas elegant
simplicity and ease of operation.

CARINA A CLEVER CHOICE

The clever-compact Carina, with its advanced


SyncPlus functionality, ease of operation and
portability will help you put your patients on
the road to recovery - quickly and comfortably.

Over 100 years

MT-8221-2005

of innovation in ventilation

With more than a century of experience


in the field of mechanical ventilation,
Drger has taken on the challenge of
creating a new ventilator.
Drger has been a pioneering force
throughout the history of respiratory
medicine, and this pioneering spirit
has gone into the development of an
innovative ventilation unit - Carina.

1907 Pulmotor emergency resuscitator


1952 E 52 Iron Lung long-term
breathing system
1978 Oxylog transportable
emergency ventilator
1989 BIPAP1 /PCV+ and APRV
free breathing in PCV
1995 AutoFlow free breathing in VCV

1995 Operating concept with


touch screen and rotary knob
1997 ATC automatic tube
compensation
2000 NIV for ICU ventilators
2003 SmartCare/PS automated
knowledge-based weaning tool
2007 Carina
1) Trademark used under licenses

HEADQUARTERS

www.draeger.com

REGION EUROPE CENTRAL


AND EUROPE NORTH

REGION MIDDLE EAST, AFRICA,


CENTRAL AND SOUTH AMERICA

Drger Medical GmbH


Moislinger Allee 5355
23558 Lbeck, Germany
Tel +49 451 882 0
Fax +49 451 882 2080
[email protected]

Drger Medical GmbH


Branch Office Dubai
Dubai Healthcare City
P.O. Box 505108
Dubai, United Arab Emirates
Tel + 971 436 24 762
Fax + 971 436 24 761
[email protected]

REGION EUROPE SOUTH

REGION ASIA / PACIFIC

Drger Mdical S.A.S.


Parc de Haute Technologie dAntony 2
25, rue Georges Besse
92182 Antony Cedex, France
Tel +33 1 46 11 56 00
Fax +33 1 40 96 97 20
[email protected]

Draeger Medical South East Asia Pte Ltd


25 International Business Park
#04-27/29 German Centre
Singapore 609916, Singapore
Tel +65 6572 4388
Fax +65 6572 4399
[email protected]

Manufacturer:
Drger Medical GmbH
23542 Lbeck, Germany
The quality management system at
Drger Medical GmbH is certified according to ISO 13485, ISO 9001 and
Annex II.3 of Directive 93/42/EEC
(Medical devices).

90 50 925 | 01.11-4 | Marketing Communications | CS | LE | Printed in Germany | Chlorine-free environmentally compatible | Subject to modifications | 2011 Drgerwerk AG & Co. KGaA

Drgerwerk AG & Co. KGaA


Moislinger Allee 5355
23558 Lbeck, Germany

Carina

MT-0564-2008

The clever-compact Carina, with its advanced NIV functionality,


ease of operation and portability will help you put your patients
on the road to recovery - quickly and comfortably.

TECHNICAL DATA

Ventilation settings
Ventilation mode

Settings
Tidal volume VT
PEEP
Inspiration pressure limit Pmax
Inspiration pressure Pinsp
Pressure support Psupp

CPAP
Ventilation frequency (f)
Inspiration time (Ti)
I:E ratio
Rise time Ramp
Trigger sensitivity
Insp. O2-concentration (FiO2)
Time setting
Application method setting
Screen type setting
Diagonal screen size
Night screen setting

Adult and pediatric patients

VC-SIMV AutoFlow1)
PC-BIPAP1)
PC-AC
SPN-PS (+VG)
SPN-CPAP
Apnea Ventilation

100 to 2000 mL, BTPS*


3 to 20 mbar (cmH2O)
5 to 50 mbar (cmH2O)
5 to 40 mbar (cmH2O) (leak valve)
5 to 50 mbar (cmH2O) (expiratory valve)
2 to 40 mbar (cmH2O) (leak valve)
2 to 50 mbar (cmH2O) (expiratory valve)
(absolute 5 mbar (cmH2O))
3 to 20 mbar (cmH2O)
5 to 50 bpm
0.3 to 8.0 s
1:39 to 2:1
Auto, 0.1 to 2.0 s
normal, sensitive, OFF
21 to 100 %
T / I:E
Mask / Tube (mask only for leak valve)
Curves / Measure
13.7 cm (5.4 inch) TFT color screen
Screen on/off

MT-0487-2007

Patient type

Carina
clever, comfortable and compact.

CARINA

Measured value displayed


Inspiratory peak pressure (PIP)
Pos. end-exp. pressure (PEEP)
Mean airway pressure (Pmean)
Inspiratory tidal volume (VT, VT)
Ventilation frequency (f)
Minute volume (MV, MV)
Minute volume leakage (MVleak)
Curve screen
Pressure (t)
Flow (t)
Bargraph screen
Pressure
Alarms / settings
Airway pressure (Paw)
Insp. minute volume MV high
Insp. minute volume MV low
Ventilation frequency f high
Delay time (Tdisconn)
Apnea alarm time (TApn)
Operating data
Mains power connection
Internal battery
Gas supply

Dimension (W x H x D)
Weight
Noise level
Max. inspiratory flow
Connections
Data port
Nurse call system
Accessories
Patient hose system
External battery

0 to 80 mbar (cmH2O)
0 to 80 mbar (cmH2O)
0 to 80 mbar (cmH2O)
0 to 4000 mL, BTPS*
0 to 80 bpm
0 to 40 L/min, BTPS*
0 to 99 L/min, BTPS*
0 to 80 mbar (cmH2O)
-160 to + 160 L/min
0 to 60 mbar (cmH2O)
10 to 55 mbar (cmH2O)
2 to 40 L/min
0.1 to 39 L/min
10 to 50 bpm
Mask 0 to 120 s (leak valve)
Tube 0 to 60 s
5 to 60 s
100 to 240 V AC (-20 to 10 %); 50 to 60 Hz; 1.7 to 1.1 A
60 min
2.7 to 6 bar (39.16 to 87.02 psi) (270 to 600 kPa)
HPO
O2-pressure
O2-Flow
0 to 120 L/min
LPO
O2-pressure
0 to 500 mbar (0 to 72.52 psi) (0 to 500 hPa)
O2-Flow
0 to10 L/min
Basic unit 175 x 275 x 385 mm (6.89 x 10.83 x 15.16 inch)
Trolley 950 x 570 x 670 mm (37.40 x 22.44 x 26.38 inch)
Basic unit 5.5 kg (12.13 lbs.)
Trolley 11.5 kg (25.35 lbs.)
Max. 40 dBA (at 10 hPa (0.15 psi))
180 L/min at 21 Vol.% O2 and normal ambient conditions
120 L/min at 100 Vol.% O2 and normal ambient conditions
RS 232 (MEDIBUS Software protocol output)
AMP/Tyco 5-555237-3, 6-pole
One hose system with leak valve
One hose system with expiratory valve
Approx. 8 h

*BTPS = Body Temperature Pressure Saturated


1) BIPAP, trademark used under license. AutoFlow, trademarked by Drger.

HEADQUARTERS

Drgerwerk AG & Co. KGaA


Moislinger Allee 5355
23558 Lbeck, Germany
www.draeger.com

REGION EUROPE CENTRAL


AND EUROPE NORTH

REGION MIDDLE EAST, AFRICA,


CENTRAL AND SOUTH AMERICA

Drger Medical GmbH


Moislinger Allee 5355
23558 Lbeck, Germany
Tel +49 451 882 0
Fax +49 451 882 2080
[email protected]

Drger Medical GmbH


Branch Office Dubai
Dubai Healthcare City, P.O. Box 505108
Dubai, United Arab Emirates
Tel + 971 436 24 762
Fax + 971 436 24 761
[email protected]

REGION EUROPE SOUTH

REGION ASIA / PACIFIC

Drger Mdical S.A.S.


Parc de Haute
Technologie dAntony 2
25, rue Georges Besse
92182 Antony Cedex, France
Tel +33 1 46 11 56 00
Fax +33 1 40 96 97 20
[email protected]

Draeger Medical
South East Asia Pte Ltd
25 International Business Park
#04-27/29 German Centre
Singapore 609916, Singapore
Tel +65 6572 4388
Fax +65 6572 4399
[email protected]

Manufacturer:
Drger Medical GmbH
23542 Lbeck, Germany
The quality management system at
Drger Medical GmbH is certified
according to ISO 13485, ISO 9001
and Annex II.3 of Directive 93/42/EEC
(Medical devices).

90 51 857 | 01.11-5 | Marketing Communications | CS | LE | Printed in Germany | Chlorine-free environmentally compatible | Subject to modifications | 2011 Drgerwerk AG & Co. KGaA

02 |