0% found this document useful (0 votes)
516 views5 pages

MML Commands

This document provides instructions for configuring a BTS in 6 steps: 1) Create D-Channel links for O&M and TRX, 2) Create a BCF, 3) Create a BTS, 4) Create a TRX, 5) Configure default power control parameters, and 6) Configure default handover control parameters. It also provides useful BSC commands for general network information, alarms, radio network configuration, BCF software, and BSC software.

Uploaded by

Aby Samuel
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
516 views5 pages

MML Commands

This document provides instructions for configuring a BTS in 6 steps: 1) Create D-Channel links for O&M and TRX, 2) Create a BCF, 3) Create a BTS, 4) Create a TRX, 5) Configure default power control parameters, and 6) Configure default handover control parameters. It also provides useful BSC commands for general network information, alarms, radio network configuration, BCF software, and BSC software.

Uploaded by

Aby Samuel
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
You are on page 1/ 5

BTS Configuration

1. Create and activate the D-Channel links for O&M and TRX

Create O&M Link (Assume P202O is the O&M link ID)


#ZDSE:P202O:BCSU,1:62,1:64,36-31:;
Activate BCSU
#ZDTC:P202O:WO;
Create TRX Link (Assume P2021 is the TRX link ID)
#ZDSE:p2021:BCSU,1:0,1:64,36-30:;
Activate TRX
#ZDTC:P2021:WO;
Check the links status by executing below commands
#ZDSB:NAME=P202O;
#ZDSB:NAME=P2021;

2. Create BCF

Assume that BCF number is 202, DNAME is as created in the O&M link:P202O)
#ZEFC:202,P:DNAME=P202O,::::;
Check the status of the BCF
#ZEEI:BCF=202:;

3. Create BTS

Assume BCF id is 202 and BCF Id is 202


#ZEQC:BCF=202,BTS=202,:CI=3299,BAND=1800:NCC=0,BCC=0:MCC=520,MN
C=18,LAC=26214:HOP=N,:GENA=Y,NSEI=1000,RAC=1,:;
NOTE: The following contents can be available in lab support database
CI, Band, MNC, MCC, LAC, NSEI, RAC

Check the status of BTS


#ZEEI:BTS=202;

4. Create TRX

Take the D-Channel name and BTS Id from step 1 to create TRX
#ZERC:BTS=202,TRX=1:PREF=P,:FREQ=544,TSC=0,PCMTSC=361:DNAME=P2021:CH0=MBCCH,CH1=SDCCH,:;
NOTE: FREQ can be available in the lab support data, PCMTSL ET36 time slot 1

5. Default Power control parameters (Assume that BTS no. is 202)


#ZEUC:BTS=202:;
6. Default Handover control parameters (Assume that BTS no. is 202)
#ZEHC:BTS=202:;

Update the BTS software build

Check the software build on 202 Id


#ZEWO:202;
List the BTS software builds
#ZEWL;
Attach the BTS software build to 202 Id
#ZEWA:202:NW:CX5_ULTRA:;
NOTE: CX5_ULTRA is one of the BTS software build
Activate the software build to BTS
#ZEWV:202:NW:;

Useful commands
1. Check the software packages and active packages on the BSC
#ZWQO:CR;
2. Check the running packages on the BSC
#ZWQO:RUN;
3. To enable EGPRS on BTS (Before executing this command lock the BTS)
#ZEQV:BTS=202:EGENA=Y,;
4. Lock BTS (Assume BTS no. is 202)
#ZEQS:BTS=202:L:;
5. Modify D-Channel working status
#ZDTC:P2021:AD:;
6. Check the D-Channel signalling link status
ZDSB:NAME=P202%
NOTE:% takes any single character
7. Delete O&M link (Delete all TRX, BTS, BCF before deleting the following link)
#ZDSD:P202O:;
8. Delete BTS (Assume that BTS no. is 202, Before executing this command lock the BTS)
#ZEQD:BTS=202::;
9. Delete BCF (Assume that BCF no.202, Before executing this command delete BTS)
#ZEEI:BCF=202::;
10. Unlock TRX (Assume that BTS no. is 202)
#ZERS:BTS=202,TRX=1,:U:;
11. Unlock BTS (Assume that BTS no. is 202)
#ZEQS:BTS=202:U:;
12. Adjust Power (Assume that BTS no. is 202)
#ZEUG:BTS=202:PMIN=30,PMAX=30:;
13. BSC Network information
#ZEEL;
14. List the status of UNITS
#ZDTI;

15. List the executed commands


#ZIGO;
16. Clearing the alarms for UNITS
#ZUST;
17. Creating DAP pool, this is needed if we are enabled EGPRS
#ZESE:ID=1,CRCT=36-25&&-29,BCSU=0,PCU=4:;
Attaching the DAP pool to TRX
ZERM:BTS=202,TRX=1:DAP=1,;
18. List O&M and Signalling D-Channel links for a particular ET number
#ZDTI:::PCM=37,:;
19. D-Channel telecom link set (Assume BTS id is 202)
#ZERO:BTS=202,TRX=1:;
20. List the units and computer identifier
#ZUSI:COMP;
21. Blocking SDCCH (BTS Id and TRX Id should be in hexadecimal number)
#ZOS:*,<computer_id>,1B4,,,,,5996,,,XW<bts_id>,<trx_id>,<tsl_id>,7
22. Deblock SDCCH
ZOS:*,<computer_id>,1B4,,,,,9500,,,XW<bts_id>,<trx_id>,<tsl_id>
23. Checking the SDCCH subchannel state information in the given TRXs
#ZDDS:;
#7 (NOTE: Define a character to be used for the extension)
#Z7T:<bts_id,trx_id>
24. Start FOXMEA service terminal extension
#ZDDS:;
#4 (NOTE: Define a character to be used for the extension)
#ZLE:4,FOX_BXSX

Useful BSC Commands

General
ZAHO
ZEOL
ZUSI

A-Interface
ZNEL
ZNET
ZNHI
ZRCI
ZDRI
ZQWI
ZNRI
ZWGO
ZWGF

Alarms currently on
BTS alarms
Unit states

Signaling Link states


Route and link set states
SCCP Subsystem states
Circuits / Circuits Groups
Synchronization
Service channel configuration
Signaling Point data
Output Transcoder PCM information
Fetch through connections from teanscoder

Abis-Interface
ZEEI
ZEFO
ZEQO
ZERO
ZEOL
ZDTI
ZRCI
ZDSB
ZRBI

Radio Network Configuration states


BCF state and parameters
BTS states and parameters
TRX states and parameters
BCF alarms currently on
D-Channel states
Circuits / Circuits Groups
D-Channel parameters
Semipermanent connections

ZEWL
ZEWO
ZEWP

Existing SW packages
SW configuration of BCF
Contents of SW packages

ZWQO:CR
ZWQH

SW packages and active packages


SW package change history

BCF SW

BSC SW

1. Useful MSC Commands

General
ZAHO
ZUSI

A-Interface
ZNEL
ZNET
ZNHI
ZRCI
ZDRI
ZNRI

D-Channel states
Circuits / Circuits Groups
D-Channel parameters

MSC SW
ZWQO:CR
ZWQH

Signaling Link states


Route and link set states
SCCP Subsystem states
Circuits / Circuits Groups
Synchronization
Signaling Point data

Circuits and D-Channels


ZDTI
ZRCI
ZDSB

Alarms currently on
Unit states

SW packages and active package


SW package charge history

HLR
ZMI_
ZMB_

Home subscriber handling


Basic service handling

You might also like