Software Installation Guide - Harris - MICROSTAR

Download as pdf or txt
Download as pdf or txt
You are on page 1of 26
At a glance
Powered by AI
The document provides instructions for upgrading the software on Microwave Digital Radios using the MicroStar Craft Interface Tool (CIT) Software.

The document is an installation guide for upgrading the software on MicroStar Digital Radio units using the Craft Interface Tool (CIT) software.

The steps involved in upgrading the software are downloading the new software file, instructing the target unit to switch to the alternate memory bank with the new software, and verifying the switch.

Microwave Digital Radios

MicroStar

Craft Interface Tool (CIT)


Software Installation Guide
P/N IMN-901660-E08

MICROSTAR
DIGITAL RADIO

CRAFT INTERFACE TOOL (CIT)


SOFTWARE INSTALLATION GUIDE
PART NO. IMN-901660-E08
SEPTEMBER 2004

MicroStar CIT

September 2004

Revision history
Issue date

Status

Description of change / revision

August 1999

C8421

Released software version 8.1.

July 2000

C8820

General update

September 2003

ECO 22159

General update

September 2004

ECO 22914

New CIT software.

Part N IMN-901660-E08
Copyright 2003 HARRIS CORPORATION. All rights reserved.
MicroStar, FARSCAN, and STARVIEW are trademarks of
HARRIS CORPORATION
Data subject to change without notice.

Harris Corporation Microwave Communications Division


350 Twin Dolphin Drive
Redwood Shores, CA 94065-1421
1-650-594-3800
1-800-227-8332
FAX: 1-650-594-3621

Harris Corporation

Harris Corporation Microwave Communications Division


3, rue de lHtel de Ville
Dollard-des-Ormeaux, Qubec,
Canada H9B 3G4
1-800-227-8332 or 1-514-421-8400
FAX: 1-514-421-3555

MicroStar CIT

WARNING
Making adjustments and/or modifications to this equipment that are not in
accordance with the provisions of this instruction manual or other
supplementary documentation may result in personal injury or damage to
the equipment, and may void the equipment warranty.

AVERTISSEMENT
Tout rglage ou modification faits cet quipement hors du cadre dict
par ce guide dutilisation ou par toute autre documentation supplmentaire
pourraient causer des blessures ou endommager lquipement et peut
entraner lannulation de sa garantie.

WARNUNG
Die an diesen Gerten gemachte Einstellungen und/oder nderungen,
welche nicht gem dieser Bedienungsanleitung, oder gem anderen
zustzlichen Anleitungen, ausgefhrt werden, knnen Verletzungen oder
Materialschden zur Folge haben und eventuell die Garantie ungltig
machen.

ATENCIN
Llevar a cabo ajustamientos y/o modificaciones a este equipo, sin seguir
las instrucciones provistas por este manual u otro documento adicional,
podra resultar en lesiones a su persona o daos al equipo, y anular la
garanta de este ltimo.

MicroStar CIT

September 2004

PREFACE
ISO 9001 Certification ..................................................................................iii
ISO 14001 Certification ................................................................................iii
Technical Assistance Center ..........................................................................iii

CHAPTER 1, SOFTWARE UPGRADE PROCEDURE


Introduction ................................................................................................ 1-1
Prerequisites ............................................................................................... 1-1
Upgrade Kit.............................................................................................. 1-1
Hardware Requirements ............................................................................ 1-2
MicroStar Network Requirements ............................................................. 1-2
Detailed Instructions .................................................................................... 1-5
Load the CIT Program on the PC ................................................................. 1-5
In Windows: ...................................................................................... 1-5
Connect the PC to the IDU ......................................................................... 1-5
Direct Connection ................................................................................. 1-6
Modem Connection................................................................................ 1-8
Perform the Network Download .................................................................. 1-8
Switch to the Alternate Software............................................................... 1-11

MicroStar CIT

Harris Corporation

CONTENTS

CONTENTS

ii

MicroStar CIT

Contents

September 2004

ISO 9001 Certification


The Harris Microwave Communications Division is committed to total
customer satisfaction and is I.S. EN ISO 9001: 1994 registered for the design,
manufacture, installation and service of microwave radio systems.

ISO 14001 Certification


Harris Microwave Communication Division believes that corporations have a
responsibility towards the environment and must operate their business in a
manner that integrates environmental preoccupation.
Harris Microwave Communications Montreal operations is I.S. EN ISO
14001:1996 registered for the design, manufacture, installation and service of
microwave radio systems.

Technical Assistance Center


Our Technical Assistance Center (TAC) is staffed with factory trained and
highly qualified Product Support staff whose task is to provide telephone
support to resolve complex customer equipment problems quickly and
accurately in a timely manner. Customers who completed product training
given by Harris Microwave Communications Division and are equipped with
proper test equipment and spare parts will experience quick resolution of their
equipment problems.
Harris Corporation Microwave Communications Division
350 Twin Dolphin Drive
Redwood Shores, CA 94065-1421, USA
Phone: 1-800-227-8332 or 1-650-594-3800
Fax: 1-650-594-3621
Email: [email protected]

Harris Corporation

MicroStar CIT

PREFACE

PREFACE

iv

Preface

Harris Corporation Microwave Communications Division


3 Hotel-de-Ville
Dollard-des-Ormeaux, Quebec
Canada H9B 3G4
Phone: 1-800-227-8332 or 1-514-421-8333
Fax: 1-514-685-4580
Email: [email protected] (point-to-point)
[email protected] (point-to-multipoint)
Harris S.A. de C.V.
Boulevard Manuel Avila Camacho #36 Piso 17
Col. Lomas de Chapultepec
C.P. 11000
Torres Esmeralda II
Mexico D.F.
Phone: +52-55-5-249 3700 or 800-872-0061
Fax: +52-55-5-249 3701 & 02
Email: [email protected]
Orbecom c/o Harris Microwave Division
Calle 101, No. 44-58
Bogota, Colombia
Phone: +57-1-533-0912
Email: [email protected]
Harris do Brasil
Edifcio STADIUM
Al. Rio Negro 1030
Conjuntos 202/204/206
CEP 06454-000
Alphaville
Barueri - SP
Phone: +55-11-4197-3000
FAX: +55-11-4197-3001
Email: [email protected]
Coasin Communicaciones S.A.
Adolfo Alsina, 1322
(C1088AAJ) Buenos Aires
Argentina
Phone: +54-11-4383-0074
Fax: +54-11-4383-0075
Email: [email protected]

MicroStar CIT

September 2004

PREFACE

Harris Communication S.A.


Centrale Parc
Avenue Sully Prudhomme
92298 Chatenay-Malabry-France
France
Phone: +33- 1-55-52-8080 or 800-55-52-8080
Fax: +33-1-55-52-8012
Email: [email protected]
Harris Communications (Shenzhen)
R3-B2 High Tech. Industrial Park
Nanshan District, Shenzhen 518057
The Peoples Republic of China
Phone: +86-755-2663-7928
Fax: +86-755-2663-7048
Trisilco Folec
36-1 Jalan PJU 8/5B, Perdana Business Centre
Bandar Damansara Perdana
47820 Petaling Jaya
Selangor Darul Ehsan
Malaysia
Phone: +60-3-7728-8228 ext. 8319
Fax: +60-3-7722-2826
Email: [email protected] or [email protected]

Visit our customer service web site at:


http://www.microwave.harris.com/cservice

Harris Corporation

MicroStar CIT

vi

MicroStar CIT

Preface

September 2004

Dear Customer,
To facilitate warranty support and to receive product update
information, please register on the Harris MCD Premier Customer
website:
https://premier.harris.com/microwave
If you are unable to register online, please complete the form
at the bottom of this page and return this page to our customer
service department.
By Fax:

514-685-4580

By email:

[email protected]

By mail:

Harris Corporation
Microwave Communications Division
3 Hotel de Ville
Dollard-des-Ormeaux, Quebec
CANADA H9B3G4

PLEASE PRINT:
Company Name:
Requestor's Name:
Title:

Dept:

Address:
City:

State/Province:

ZIP/Postal Code:

Country:

Telephone Number:

Fax Number:

Email:
Original Sales Order/PO Number:
Sales order numbers are found in your documentation and are stencilled on the equipment rack base plate,
for example, A44044A1.

viii

MicroStar CIT

Preface

September 2004

Introduction
This document outlines the software upgrade procedure for the MicroStar
IDUs, using the CIT program. When installed on a PC, the CIT program allows
you to upgrade the software in any IDU that is part of a network.
Once the download is initiated, the software is installed in the alternate
memory bank of the target IDU.

This download does not prevent the IDU from passing


traffic normally, and lasts about 20 minutes, depending
on the number of links.
When the download terminates, the user commands the IDU to switch to the
alternate memory bank thereby enabling the newly loaded software.

Prerequisites
In order to complete a successful software upgrade, the following conditions
are required.

Upgrade Kit
The upgrade kit contains the following items:
1. One CDROM labeled CIT. This disk contains the CIT program that allows
you to upgrade the IDU software from a remote site.
2. One serial cable, Harris part number 087-900271-480, to connect a
computer or laptop to the CIT port on the IDU.

Harris Corporation

MicroStar CIT

SOFTWARE
UPGRADE
PROCEDURE

SOFTWARE UPGRADE
PROCEDURE

1-2

Software Upgrade Procedure

Hardware Requirements
The computer used for this upgrade must have the following hardware
configuration, as a minimum.
1. A Pentium II CPU, 250 MHz, 64 MB of RAM, and 20 MB free hard disk
space.
2. A SVGA monitor controller (color or monochrome display).
3. Small font support (1024 by 768).
4. Windows NT/2000/XP.
5. A pointing device, and a keyboard.
6. Internet Explorer 5.5 (or later).

MicroStar Network Requirements


The CIT will operate in a heterogeneous network of MicroStar IDUs. For the
tool to operate, the network must satisfy two conditions:
1. Each IDU, in a given network, must be assigned a unique Network Element
(NE) address. For instructions on assigning an NE address to an IDU, refer
to the respective MicroStar Instruction Manual.
2. The network must be physically wired to support network management. In
other words, the repeater connectors on the IDUs must be connected
together. For a typical repeater arrangement, refer to Figure 1-1 through
Figure 1-3. Note that the modem is optional in all scenarios.

MicroStar CIT

September 2004

Prerequisites

1-3

Figure 1-1:

Network Download Typical Scenario 1


SOFTWARE
UPGRADE
PROCEDURE

SERIAL CABLE

MODEM

TELEPHONE LINE

LAPTOP
RUNNING
CIT
SOFTWARE

Figure 1-2:

PUBLIC
SWITCHED
TELEPHONE
NETWORK

CIT

Software

MODEM

Network Download Typical Scenario 2

SERIAL CABLE
LOCAL REPEATER
(DAISY CHAIN)
ARRANGEMENT

MODEM
TELEPHONE LINE

LAPTOP
RUNNING
CIT
SOFTWARE

Harris Corporation

CIT

Software

MODEM

PUBLIC
SWITCHED
TELEPHONE
NETWORK

MicroStar CIT

1-4

Software Upgrade Procedure

Figure 1-3:

Network Download Typical Scenario 3

SERIAL CABLE
MODEM
MEGASTAR
NETWORK
TELEPHONE LINE

LAPTOP
RUNNING
CIT
SOFTWARE

Figure 1-4:

CIT

Software

MODEM

PUBLIC
SWITCHED
TELEPHONE
NETWORK

Network Download Typical Scenario 4

CIT CABLE
(Part #087-900271-480)

LAPTOP
RUNNING
CIT
SOFTWARE

MicroStar CIT

CIT

Software

September 2004

Detailed Instructions

1-5

Detailed Instructions

Load the CIT program on the PC


Connect the PC to an IDU
Perform the Network Download
Switch to the Alternate Software

The first step need only be performed once; the remaining steps are performed
for each IDU that must be upgraded.

As an alternative for better performance, you can also


copy the IDU upgrade software (.zip file) to a folder of
your choice on the PC.

Load the CIT Program on the PC


In Windows:
1. Insert the CD labeled CIT in the CDROM drive (here, D:).
2. Click on the Start button and then Run.
3. Type D:\setup.exe in the Open text field of the Run dialogue box, then
click on the OK button.
4. Follow the on-screen instructions to install the CIT Program in the default
folder or a folder of your choice.

Connect the PC to the IDU


The download to any IDU in the network can be executed by connecting the PC
to any IDU in the network. The PC can be connected directly to an IDU, or it
can be connected through modems.

Harris Corporation

MicroStar CIT

SOFTWARE
UPGRADE
PROCEDURE

To successfully upgrade the software into the target IDU, there are four steps that
must be followed.

1-6

Software Upgrade Procedure

Direct Connection
This is accomplished by connecting a serial cable (Harris P/N 087-900271480)1 between the PCs serial port (usually COM1) and the connector labeled
CIT on the IDU. For locating the CIT port on the IDU, refer to Figure 1-5
through Figure 1-7.
Figure 1-5:

Locating the CIT and Repeater Ports on the IDU


of the MicroStar Plus Radio
REPEATER IN

FRONT VIEW

REPEATER OUT
IDU
REAR VIEW

CIT
PORTS

1. This DB-9/DB-9 cable has a straight type pin-to-pin wiring and is EMI compliant.

MicroStar CIT

September 2004

Detailed Instructions

Figure 1-6:

1-7

Locating the CIT and Repeater Ports on the IDU


of the MicroStar Radio

REPEATER OUT

REAR VIEW

CIT
PORTS
Figure 1-7:

Locating the CIT and Repeater Ports on the IDU


of the Protected MicroStar and MicroStar Plus
Radios

REPEATER IN
REPEATER OUT

CIT
PORT

Harris Corporation

MicroStar CIT

SOFTWARE
UPGRADE
PROCEDURE

REPEATER IN

FRONT VIEW

1-8

Software Upgrade Procedure

Modem Connection
In this configuration, the IDU is located remotely from the PC. The PCs serial
port is connected to the first modem and that modem is connected to the phone
lines. The second modem, at the remote site, is connected to the CIT port of the
IDU at that site, using a suitable serial cable. For locating the CIT port on the
IDU, refer to figures Figure 1-5 through Figure 1-7. As a reference, Figure 1-8
shows a wiring diagram of a suitable cable2. Apply power to both modems.
Figure 1-8:

Typical Wiring Diagram of a Suitable Serial Cable


Pin no

DB-25
MALE
TO
MODEMS
PORT

Pin no
DCD
RX

1
2

TX

DTR

1
2

TX

RX

6
7

DSR
GND

GND

20

DTR

DSR

DCD

RTS

RTS

CTS

RI

DB-9
MALE
TO
CIT
PORT

Perform the Network Download


1. Start the CIT Program.
2. When the Connect To box appears (see Figure 1-9), select the appropriate
Com port and click OK. If you want to connect to a different IDU, select
Any Site Connection under ESCAN Connection and then enter the NE
address of the IDU you want to connect to.

If the remote and local IDUs have the same address,


then modify the local IDUs address to be different from
the remote one and proceed with the download using
the known address.

2. This DB-9/DB-25 cable must be EMI compliant.

MicroStar CIT

September 2004

Detailed Instructions

Figure 1-9:

1-9

Connect To Box
SOFTWARE
UPGRADE
PROCEDURE

3. Once you have connected, select Administration > Software Download


from the menu bar located at the side of the screen.

Harris Corporation

MicroStar CIT

1-10

Software Upgrade Procedure

Figure 1-10: The Software Download Window

4. Insert the IDU Upgrade Software disk in the CDROM disk drive, (D:).
From the Software Download window, specify the file to download by
clicking on the File to Download button, and then enter the proper file
name. Specify the full path of the file, i.e., Drive:\Directory\ filename.zip.
Remember that the file name must end with .zip.
5. Press the APPLY button to start the download. A status window will
appear displaying the progress of the download, step-by-step. When the
process completes, proceed to "Switch to the Alternate Software" on
page 11. Note that you can abort the download process at any time during
these steps.

MicroStar CIT

September 2004

Detailed Instructions

1-11

Switch to the Alternate Software

1. From the menu bar located at the side of the screen, select Administration
> Software Upgrade.
Figure 1-11: The Software Upgrade Window

2. The Software Upgrade window should display the software versions that
are currently present in the running and alternate memory banks of the
selected IDU (see Figure 1-11). If the information displayed is accurate,
continue.
3. Enter a value in the New Value (Sec) box that is different than 0.This
value represents the number of seconds that the IDU will count down
before it switches to the alternate software. For example, entering a value
of 10 seconds will cause the IDU to count down 10 seconds before it
switches to the alternate software version.
4. Click the Switch to Alt. Software button.

Harris Corporation

MicroStar CIT

SOFTWARE
UPGRADE
PROCEDURE

Once the software has been downloaded, the user must instruct the target IDU
to switch to the new software.

1-12

Software Upgrade Procedure

Once started, ensure not to disrupt this switching


operation for at least 5 minutes. During this
period, an auto-download is initiated from the
IDU to the ODU; this requires that no other
download takes place simultaneously over the
network. Failure to do so, may cause a download
failure and a system lock-up.
5. The CIT will display a Communication lost! window (see Figure 1-12); this
is normal since communications will be lost while the target IDU switches
to the alternate software. Wait approximately 45 seconds. To re-establish
communications click the Retry button in the Communication lost!
window. When the CIT communicates with the target IDU, the Running
Software Version and Alternate Software Version should have swapped.
You can check this by going to Administration > Software Upgrade
again.
Figure 1-12: The Communication lost! Window

MicroStar CIT

September 2004