Lifting
Lifting
Lifting
CONCRETE
Software support
To facilitate your choice of anchor and
anchor dimensions, we supply the
dimensioning program "TPA-WIN"
free of charge. Please visit our website
www.halfen-deha.com to download
our software. Once the desired anchor
type, the dimensions of the unit and
the handling conditions (lifting beam,
angled pull, etc.) have been entered,
the program determines the appropriate anchor and the additional
reinforcement. Scale drawings and
parts lists can be printed out.
Technical advice
The staff of our technical offices and
our specialists in the field will be glad
to advise you on how to deal with
problematic applications. Consult the
back page of this catalogue for the
addresses.
Page
System components
6-7
Anchor types
8-9
Dimensioning
10
Multiple slings
11-12
Dimensioning examples
Page
Anchors
13
14-18
19-21
22-25
26-27
28
29
30-31
32
33
Page
Anchor installation
34
General Instructions
35-37
Recess formers
38-39
Holding plates
39
Holding bolts
40
Recess fillers TPA-V1 and cover plate TPA-V2 for anchor recess
Page
Ring clutches
41
Installation
42
TPA-R1
43
44-45
TPA-F1
46-47
TPA-F2
48
Application
49
Page
Service
50
Order form
51
Addresses
Fig. I
System type
designation F
Anchor type
S = Spread anchor
Z = Two hole anchor
P = Plate anchor
A = Erection anchor
E = Unilateral erection anchor
G = Garage anchor
F = Flat foot anchor
D = Double ended column anchor
X = Sandwich panel anchor
U = Universal anchor
Anchor length
length = 13 cm
Note
The values for load groups and load
ranges are given in metric tons [t].
1 t is equivalent to 10 kN.
Fig. 2
The ring clutch can move in any
direction
Load range
anchor
[t]
0,7
2,5
1,4
2,0
2,5
3,0
5,0
4,0
5,0
10,0
7,5
10,0
12,5
14,0
26,0
17,0
22,0
26,0
Manufacturers
sign FR
The anchors
TPA-FS
TPA-FZ
TPA-FA
TPA-FX
TPA-FD
TPA-FP
TPA-R1
TPA-FE
TPA-R2
TPA-R3
TPA-F1
Each anchor bears clearly visible stamped markings with the name of the
manufacturer FRIMEDA, the description of the system (F), the anchor type
(S), the anchor length (13) and the
load range in tons (2.0) (Fig. I)
TPA-FF
TPA-FG
TPA-F2
Main applications:
Columns, Beams, Trusses, Wall units,
Double T-slabs
Parameters:
Component thickness
Concrete grade
Reinforcement
Tables p. 14 - 18
Main applications:
Prestressed concrete trusses, Thinwalled elements, Low strength
concrete (e.g. lightweight concrete)
Parameters:
Component thickness
Concrete grade
Reinforcement
Tables p. 19 - 21
er
er
Main applications:
Thin-walled concrete elements, being
lifted from a horizontal to a perpendicular position.
Parameters:
Component thickness
Concrete grade
Reinforcement
Tables p. 22 - 25
Applications:
Columns
Parameters:
Component thickness
Concrete grade
Reinforcement
Tables p. 30 - 31
Main applications:
Ceiling slabs with surface-embedded
anchors, Tubes
Parameters:
Component thickness
Concrete grade
Reinforcement
Tables p. 26 - 27
Main applications:
Very thin ceiling slabs with surfaceembedded anchors
Parameters:
Component thickness
Concrete grade
Reinforcement
Tables p. 28
Main applications:
Precast concrete garages, embedding
in floor or ceiling slab
Parameters:
Component thickness
Concrete grade
Tables p. 29
Main applications:
Sandwich panels
Parameters:
Component thickness
Concrete grade
Reinforcement
Tables p. 32
Main applications:
see TPA-FS, TPA-FZ and TPA-FA
Parameters:
Component thickness
Concrete grade
Reinforcement
Tables p. 33
Safety rules
Deadweight
Dynamic forces
g = 2,5
g=4
Ha = q x A
Ha = 2 x G
Ha = 4 x G
Lifting
class
H3
H4
1,4 + 0,0088
H1
H2
VH
Total load
The total load of the precast unit for
dimensioning the anchor is determined as follows:
1. During lifting:
V 1 = G + Ha
2. During transporting:
A is the area of contact between
the mould and the unit before lifting.
1
2,2
V =Gxf
2
Note:
Unequal anchor loads when the suspension points are not symmetrical in
relation to the centre of gravity:
z = 1/ cos
Vtot
V tot
Spreader beam
b
Fa
Fb
S = centre of
gravity
d =2x b
F a = V tot x
F b = V tot x
b
a+b
Cable angle b
1,00
7,5
1,01
15,0
1,04
22,5
1,08
30,0
1,16
37,5
1,26
45,0
1,41
52,5
1,64
60,0
2,00
a
a+b
For a symmetrical arrangement, the
tensile force on the anchor is:
F = z x Vtot / n
n = number of load-bearing anchors
(see also section "Multiple slings",
page 10)
For a beam with more than two suspension points and for a panel with
more than three, it is impossible to
work out the load per anchor precisely, even if the anchors are
arranged symmetrically to the load
centre. As a result of unavoidable
tolerances in the suspension system
and in the position of the anchors, it
can never be determined whether
the load on each anchor is equal.
Examples:
The use of three anchors ensures that
the static load ist shared evenly.
Vtot
Number of loadbearing anchors:
n=3
b
F
Vtot
Vtot
F d
120
F
Number of
load-bearing
anchors: n = 2
Number of
load-bearing
anchors: n = 4
Vtot
Vtot
F
F
b
F
F
F
F
Number of
load-bearing
anchors: n = 4
10
G
Number of
load-bearing
anchors: n = 4
Example
Slab unit
G Mass
A Mould area
q Adhesion to mould
f Lifting load coeffic.
z Cable angle factor
w Concrete strength
Manufacturing plant
Lifting
Transport
10 t (~ 100 kN)
On site
10 t (~ 100 kN)
20 m 2
2 kN/m
1,0
1,1
1,4
1,41 ( b = 45)
1,04 ( b= 15)
15 N/mm 2
35 N/mm
With 2 supporting anchors, the angled pull force F per anchor is as follows:
Lifting at the plant:
F = (G + q x A) x f x z/n
F = G x f x z/n
F = G x f x z/n
Adhesion to mould
The loads occurring on site are often higher than in the manufacturing plant as a
result of greater cable spread and possibly higher lifting force coefficients. In this
instance, it is beneficial that the concrete's strength is usually likewise higher, and
that the anchor's load capacity in the concrete is thus higher.
In the above example, the result for a TPA-FS (see p. 16) would be as follows:
At the manufacturing plant (w = 15 N/mm, cable angle 15):
Angled pull 15 < 30
=> full permissible load at angled pull, even with
w= 15N/mm
Lifting load
11
P-slab
Lifting and transporting at the manufacturing plant:
Concrete strength when lifted: b W 25 N/mm 2
Cable angle: b = 30
Cable angle factor: z = 1,16
Lifting load coefficient (Transporting): f = 1,1
Lifting load coefficient (Lifting): f = 1,0
Loads:
2
Deadweight: G = (0,1 x 3,0 + 2 x 0,3 ) x 8,7 x 25 = 104,4 kN
Adhesion to mould:
Ha = 2 x G
= 208,8 kN
Total load:
= 313,2 kN
Q = Ha + G
Load per anchor during lifting:
F = 1,16 x 1,0 x 313,2 = 90,8 kN
4
10
30
30
75
25
TPA-FS 10,0-30
(acc. to table p. 16)
87
15
25
75
Dimensions in cm
Wall slab
Lifting at the manufacturing plant and transporting on the construction site
Concrete strength when lifting: b W 15 N/mm 2
Adhesion to mould: q = 1 kN/m 2
Lifting load coefficient of the crane: f = 1,1 (lifting at the plant)
f = 1,3 (transporting on the site)
Loads:
Dead weight: G = 0,16 x 7,0 x 2,5 x 25 = 70,0 kN
Adhesion to mould: Ha = 2,5 x 7,0 x 1 = 17,5 kN
Total load:
= 87,5 kN
Q = G + Ha
Load per anchor during lifting:
F = 1,1 x 87,5 x 0,5 = 24,1 kN
1
2
Load per anchor during transporting:
F2 = 1,3 x 70 = 45,5 kN
2
16
Anchor selected:
TPA-FA 5,0-29
(acc. to table p. 24) Fperm,lifting
25 kN > 24,1 kN
Fperm,transporting 50 kN > 45,5 kN
70
25
12
16 l = 1000 mm
Dimensions in cm
e
z
,5
0
e r
e
r
e r
ez
ez
Link
e
r
e
r
k
Mesh reinforcement
d = Anchor length
d
k = Cover to anchor head
= Concrete cover acc. to DIN 1045
Load direction
Symbol
Incorrect
Correct
13
Order No.
0070.01000001
TPA-FS 0,7-11
Additional hole
a
[mm]
b
[mm]
c
[mm]
d
[mm]
30
14
110
TPA-FS 1,4-11
00002
30
14
110
TPA-FS 1,4-16
00003
30
14
160
TPA-FS 2,0-13
00004
30
14
130
TPA-FS 2,0-16
00005
30
14
160
TPA-FS 2,0-21
00006
30
14
210
TPA-FS 2,5-15
00007
30
14
10
150
TPA-FS 2,5-20
00008
30
14
10
200
TPA-FS 2,5-25
00009
30
14
10
250
a
[mm]
b
[mm]
c
[mm]
d
[mm]
Order No.
TPA-FS 3,0-16
0070.01000010
40
18
10
160
TPA-FS 3,0-20
00011
40
18
10
200
TPA-FS 3,0-28
00012
40
18
10
280
TPA-FS 4,0-18
00013
40
18
12
180
TPA-FS 4,0-24
00014
40
18
12
240
TPA-FS 4,0-32
00015
40
18
12
320
TPA-FS 5,0-18
00016
40
18
15
180
TPA-FS 5,0-24
00017
40
18
15
240
TPA-FS 5,0-40
00018
40
18
15
400
a
[mm]
b
[mm]
c
[mm]
d
[mm]
How to order:
Selected anchor
Load group 10,0 t (7,5 t - 10,0 t)
Type
Load range
Anchor length in cm
Designation
TPA-FS 4,0 - 32
Order No.:
Order No.
0070.01000022
TPA-FS 7,5-26
0070.010-00015
60
26
16
260
TPA-FS 7,5-30
00023
60
26
16
300
TPA-FS 7,5-42
00024
60
26
16
420
TPA-FS 10,0-30
00025
60
26
20
300
TPA-FS 10,0-37
00026
60
26
20
370
TPA-FS 10,0-52
00027
60
26
20
520
a
[mm]
b
[mm]
c
[mm]
d
[mm]
370
Load group
Cover to
anchor head
14
Designation
Order No.
0070.01000028
TPA-FS 14,0-37
[t]
2,5 t
5,0 t
10,0 t
26,0 t
k
[mm]
10
10
15
15
80
35
20
TPA-FS 14,0-46
00029
80
35
20
460
TPA-FS 22,0-50
00030
80
35
26
500
TPA-FS 22,0-62
00031
80
35
26
620
Designation
Permitted load
5,0
10,0
26,0
[mm]
[t]
[mm]
[mm]
[mm]
[mm]
110
0,7
35
35
35
280
TPA-FS 1,4 - 11
110
1,4
70
50
40
380
TPA-FS 2,0 - 13
130
2,0
90
60
50
455
TPA-FS 2,0 - 16
160
2,0
70
50
40
665
TPA-FS 2,5 - 15
150
2,5
100
75
60
525
TPA-FS 2,5 - 20
200
2,5
75
55
45
700
TPA-FS 3,0 - 16
160
3,0
110
80
60
560
TPA-FS 3,0 - 20
200
3,0
85
60
50
700
TPA-FS 4,0 - 18
180
4,0
150
100
80
630
TPA-FS 4,0 - 24
240
4,0
100
75
60
840
TPA-FS 5,0 - 18
180
5,0
190
140
110
630
TPA-FS 5,0 - 24
240
5,0
150
100
80
840
TPA-FS 7,5 - 26
260
7,5
220
170
125
910
TPA-FS 7,5 - 30
300
7,5
190
140
110
1050
TPA-FS 10,0 - 30
300
10,0
275
200
175
1050
TPA-FS 10,0 - 37
370
10,0
220
160
125
1295
TPA-FS 14,0 - 37
370
14,0
400
280
225
1295
TPA-FS 14,0 - 46
460
14,0
300
220
175
1610
TPA-FS 22,0 - 50
500
22,0
450
340
300
1750
TPA-FS 22,0 - 62
620
22,0
400
280
225
2170
e
r
e
r
t=d+k+
ez
e z
er
for b W
35 N/mm
TPA-FS 0,7 - 11
[t]
2,5
er
for b W
25 N/mm
Minimum spacing
between centres
ez
0,5
Mesh
reinforcement
131 mm/m, crosswise
e
z
e
r
er
ez
er
15
100% Fperm
100% Fperm
F
80%
F
80%
F 30 30
F 30 30
80%
er er
ez /2
ez /2
Load
group
Designation
[t]
2,5
5,0
26,0
16
Anchor
length
d
[mm]
100 % Fperm
Pull
(b 30)
[t]
80 % Fperm
Angle pull
(b > 30)
[t]
TPA-FS
TPS-FS
TPA-FS
TPA-FS
0,7 - 11
1,4 - 11
1,4 - 16
2,0 - 13
110
330
70
60
50
0,7
0,6
110
330
90
70
70
1,4
1,1
160
480
80
60
60
1,4
1,1
130
390
110
90
90
2,0
1,6
TPA-FS
TPA-FS
TPA-FS
TPA-FS
TPA-FS
TPA-FS
TPA-FS
2,0 - 16
2,0 - 21
2,5 - 15
2,5 - 20
2,5 - 25
3,0 - 16
3,0 - 20
160
480
100
80
80
2,0
1,6
210
630
90
70
70
2,0
1,6
150
450
120
80
80
2,5
2,0
200
600
110
80
70
2,5
2,0
250
750
100
80
70
2,5
2,0
160
480
120
100
100
3,0
2,4
200
600
110
90
90
3,0
2,4
TPA-FS 3,0 - 28
TPA-FS 4,0 - 18
TPA-FS 4,0 - 24
TPA-FS 4,0 - 32
TPA-FS 5,0 - 18
TPA-FS 5,0 - 24
TPA-FS 5,0 - 40
TPA-FS 7,5 - 26
TPA-FS 7,5 - 30
TPA-FS 7,5 - 42
TPA-FS 10,0 - 30
280
840
100
80
80
3,0
2,4
180
540
140
120
100
4,0
3,2
240
720
130
110
100
4,0
3,2
320
960
120
100
100
4,0
3,2
180
540
180
140
140
5,0
4,0
240
720
160
120
120
5,0
4,0
400
1200
140
100
100
5,0
4,0
220
660
180
140
100
5,3
4,2
260
780
160
130
100
5,3
4,2
340
1020
140
100
100
5,3
4,2
300
900
280
200
160
10,0
8,0
370
1110
240
160
160
10,0
8,0
520
1560
200
140
120
10,0
8,0
370
1110
300
250
200
14,0
11,2
TPA-FS 10,0 - 37
TPA-FS 10,0 - 52
TPA-FS 14,0 - 37
TPA-FS 14,0 - 46
TPA-FS 22,0 - 50
TPA-FS 22,0 - 62
460
1380
240
200
160
14,0
11,2
500
1500
400
300
250
22,0
17,6
620
1860
300
250
250
22,0
17,6
Reinforced zone
3-fold anchor length d
b
Edge reinforcement
sh
Me
L1
en
em
rc
nfo
rei
LQ = overall length
(approx. 2 x length of leg)
Load
range
[t]
[t]
2,5
0,7
1,4
2,0
2,5
3,0
4,0
5,0
7,5
10,0
14,0
22,0
5,0
10,0
26,0
Mesh reinf.*
both sides
crosswise
[mm/m]
Slot-in link *
n dia. ... x L1
[mm]
Edge
Mesh reinf.*
reinforcem.* both sides
crosswise
[mm/m]
[mm]
131
constructive
constructive
131
2 dia. 6 x 400
constructive
131
2 dia. 6 x 500
131
Slot-in links *
Edge
reinforcem.*
Angle pull
reinforcement *
n dia. ... x L Q
[mm]
n dia. ... x L 1
[mm]
[mm]
131
4 dia. 6 x 300
dia. 8
dia. 6 x 450
131
4 dia. 6 x 400
dia. 8
dia. 6 x 900
constructive
131
4 dia. 6 x 500
dia. 8
dia. 8 x 950
2 dia. 8 x 600
constructive
131
4 dia. 8 x 600
dia. 10
dia. 8 x 1200
131
2 dia. 8 x 700
constructive
131
4 dia. 8 x 700
dia. 10
dia. 10 x 1150
131
2 dia. 8 x 800
constructive
131
4 dia. 8 x 800
dia. 12
dia. 10 x 1500
131
2 dia. 10 x 800
constructive
131
4 dia. 10 x 800
dia. 12
dia. 12 x 1550
188
4 dia. 10 x 800
dia. 10
188
4 dia. 10 x 800
dia. 12
dia. 14 x 2000
188
6 dia. 10 x 1000
dia. 12
188
6 dia. 10 x 1000
dia. 14
dia. 16 x 2300
257
6 dia. 10 x 1000
dia. 14
257
8 dia. 10 x 1000
dia. 14
dia. 20 x 2600
257
8 dia. 10 x 1200
dia. 14
257
8 dia. 10 x 1200
dia. 16
dia. 28 x 3450
17
Concrete strength b W
Load
group
15 N/mm
Designation
5,0
10,0
26,0
Permitted
load
Erecting and
turning reinforcement
dia.
[mm]
Transport
[t]
[t]
Erecting
ez
[mm]
0,7 - 11
1,4 - 16
2,0 - 21
2,5 - 25
3,0 - 28
100
700
600
0,70
0,56
0,35
100
700
10
700
1,40
1,12
0,70
100
800
10
750
2,00
1,60
1,00
100
875
12
800
2,50
2,00
1,25
150
950
12
850
3,00
2,40
1,50
TPA-FS 4,0 - 32
TPA-FS 5,0 - 40
TPA-FS 7,5 - 42
TPA-FS 10,0 - 52
TPA-FS 14,0 - 46
TPA-FS 22,0 - 62
150
1050
14
950
4,00
3,20
2,00
150
1435
16
1000
5,00
4,00
2,50
250
1470
20
1200
7,50
6,00
3,75
300
1820
20
1500
10,00
8,00
5,00
525
1800
25
1800
14,00
11,20
7,00
710
2200
28
1800
22,00
17,60
11,00
TPA-FS
TPA-FS
TPA-FS
TPA-FS
TPA-FS
Lw 1
[mm]
Transport
er
[mm]
[t]
2,5
[t]
Anchor orientation
must be as illustrated
er
er
0,5 e
z
0,5 e
z spa
c
ing t
Lw
o th
e ne
xt an
chor
h = depends on the
component thickness
90
Reinforcement steel: Yield strength 500 N/mm,
tensile strength 550 N/mm
1
Lw = Length before bending
Bending radius acc. to DIN 1045
18
dia.
Order No.
a
[mm]
b
[mm]
c
[mm]
d
[mm]
TPA-FZ 1,4-9
0070.02000002
30
14
90
TPA-FZ 2,0-9
00003
30
14
90
TPA-FZ 2,5-9
00004
30
14
10
90
a
[mm]
b
[mm]
c
[mm]
d
[mm]
120
Order No.
0070.02000005
TPA-FZ 3,0-12
40
18
10
TPA-FZ 4,0-12
00006
40
18
12
120
TPA-FZ 5,0-12
00007
40
18
15
120
a
[mm]
b
[mm]
c
[mm]
d
[mm]
60
26
16
160
60
29
20
165
a
[mm]
b
[mm]
c
[mm]
d
[mm]
240
TPA-FZ 7,5-16
0070.02000009
TPA-FZ 10-17
00010
How to order:
Designation
Selected anchor
Order No.
0070.02000011
TPA-FZ 14,0-24
Type
Load range
Anchor length in cm
TPA-FZ 7,5 - 16
80
35
20
TPA-FZ 22,0-30
00013
80
35
26
300
TPA-FZ 26,0-30
00012
120
65
30
300
Load group
Cover to
anchor head
Designation
[t]
2,5 t
5,0 t
10,0 t
26,0 t
k
[mm]
10
10
15
15
19
100% Fperm
100% Fperm
80%
Fperm
F
80%
Fperm
F 30 30
F 30 30
80% 2
F Fperm
er er
ez /2
ez /2
Concrete strength b W
Load
group
Designation
[t]
2,5
5,0
10,0
26,0
20
15 N/mm
Anchor
length
d
[mm]
Spacing between
anchor centres
ez
[mm]
Minimum thickness
of precast unit
(2 x e r )
[mm]
100% Fperm
Pull
( b 30)
[t]
80% Fperm
Angled pull
( b > 30)
[t]
TPA-FZ 1,4 - 9
TPA-FZ 2,0 - 9
TPA-FZ 2,5 - 9
90
500
80
1,4
1,1
90
600
90
2,0
1,6
90
600
100
2,5
2,0
TPA-FZ 3,0 - 12
TPA-FZ 4,0 - 12
TPA-FZ 5,0 - 12
TPA-FZ 7,5 - 16
TPA-FZ 10,0 - 17
TPA-FZ 14,0 - 24
120
650
100
3,0
2,4
120
700
110
4,0
3,2
120
750
120
5,0
4,0
160
1200
130
7,5
6,0
165
1200
140
10,0
8,0
240
1500
160
14,0
11,2
TPA-FZ 22,0 - 30
TPA-FZ 26,0 - 30
300
1500
180
22,0
17,6
300
1500
200
26,0
20,8
~ LZ/2
re
L1
sh
Me
~ 0,7 x LZ/2
en
em
orc
inf
30
LZ
L Q = overall length
(approx. 2 x length of leg)
Pull ( b 30)
Load Mesh reinf.*
range both sides
crosswise
[mm/m]
[t]
1,4
2,0
2,5
3,0
4,0
5,0
7,5
10,0
14,0
22,0
26,0
Slot-in links *
n dia. ... x L1
[mm]
Edge
reinf.*
[mm]
Edge
Add. reinf.
Mesh reinf.* Slot-in links *
for pull *
both sides
reinforcem.*
n dia. ... x L1
n dia. ... x LZ
crosswise
[mm]
[mm]
[mm/m]
[mm]
131
131
131
131
131
131
131
131
2 dia. 10 x 800
dia. 10
1 dia. 20 x 1750
4 dia. 10 x 800
dia. 12
1 dia. 25 x 1850
131
131
131
4 dia. 10 x 1000
dia. 14
1 dia. 28 x 2350
4 dia. 12 x 1200
dia. 14
1 dia. 28 x 3000
6 dia. 12 x 1200
dia. 14
2 dia. 28 x 3050
Add. reinf.
for pull *
n dia. ... x LZ
[mm]
Angled pull
reinforcem.*
dia. ... x LQ
[mm]
131
131
4 dia. 6 x 400
dia. 8
1 dia. 10 x 650
dia. 6 x 900
4 dia. 6 x 500
dia. 8
1 dia. 12 x 800
dia. 8 x 950
131
131
131
4 dia. 8 x 600
dia. 10
1 dia. 12 x 1000
dia. 8 x 1200
4 dia. 8 x 700
dia. 10
1 dia. 14 x 1000
dia. 10 x 1150
4 dia. 8 x 800
dia. 12
1 dia. 16 x 1200
dia. 10 x 1500
131
131
131
4 dia. 10 x 800
dia. 12
1 dia. 16 x 1500
dia. 12 x 1550
4 dia. 10 x 800
dia. 12
1 dia. 20 x 1750
dia. 14 x 2000
6 dia. 10 x 1000
dia. 14
1 dia. 25 x 1850
dia. 16 x 2300
131
131
131
8 dia. 10 x 1000
dia. 14
1 dia. 28 x 2350
dia. 20 x 2600
8 dia. 10 x 1200
dia. 16
1 dia. 28 x 3000
dia. 25 x 3000
8 dia. 12 x 1200
dia. 16
2 dia. 28 x 3050
dia. 28 x 3450
21
Order No.
0070.030TPA-FA 1,4-20
00001
TPA-FA 2,5-23
00002
a
[mm]
c
[mm]
d
[mm]
g
[mm]
55
200
45
55
10
230
45
a
[mm]
c
[mm]
d
[mm]
g
[mm]
70
12
270
70
70
15
290
70
a
[mm]
c
[mm]
d
[mm]
g
[mm]
95
15
320
90
95
20
390
90
a
[mm]
c
[mm]
d
[mm]
g
[mm]
90
Order No.
0070.03000003
TPA-FA 4,0-27
TPA-FA 5,0-29
00004
Order No.
0070.03000005
TPA-FA 7,5-32
00006
TPA-FA 10,0-39
How to order:
Selected anchor
Type
Load range
Anchor length in cm
Designation
Order No.
0070.03000007
TPA-FA 12,5-50
TPA-FA 4,0 - 27
148
20
500
TPA-FA 17,0-50
00008
148
25
500
90
TPA-FA 22,0-50
00009
148
30
500
90
Load group
Cover to
anchor head
22
k1
[t]
2,5 t
5,0 t
10,0 t
26,0 t
k
[mm]
10
10
15
15
k1
[mm]
Order No.
0070.040TPA-FE 1,4-20
00001
TPA-FE 2,5-23
a
[mm]
c
[mm]
d
[mm]
g
[mm]
40
200
42,5
40
10
230
42,5
a
[mm]
c
[mm]
d
[mm]
g
[mm]
55
12
270
50,5
55
15
290
50,5
a
[mm]
c
[mm]
d
[mm]
g
[mm]
80
15
320
78
80
20
390
78
a
[mm]
c
[mm]
d
[mm]
g
[mm]
88,5
00002
Order No.
0070.04000003
TPA-FE 4,0-27
TPA-FE 5,0-29
00004
Order No.
0070.04000005
TPA-FE 7,5-32
00006
TPA-FE 10,0-39
How to order:
Load group 26,0 t (12,5 t - 26,0 t)
Selected anchor
Designation
Type
Load range
Anchor length in cm
Order No.
0070.04000007
TPA-FE 12,5-50
TPA-FE 5,0 - 29
115
20
500
TPA-FE 17,0-50
00008
115
25
500
88,5
TPA-FE 22,0-50
00009
115
30
500
88,5
Load group
Cover to
anchor head
k1
[t]
2,5 t
5,0 t
10,0 t
26,0 t
k
[mm]
10
10
15
15
k1
[mm]
23
Transport
b
Erection
100% Fperm
100% Fperm
F
80%
Fperm
15
50%
Fperm
F 30 30
ez /2
50%
F Fperm
F
*)
15
*)
N/mm2
d
er er
[t]
[t]
2,5
1,4
2,5
4,0
5,0
7,5
10,0
5,0
10,0
26,0
24
Load
range
12,5
17,0
22,0
Anchor
length
Spacing between
anchor centres
d
[mm]
ez
[mm]
200
230
Minimum thickness
of precast element
(2 x e r )
Transport
Pull
( b 30)
100% Fperm
[t]
Transport
Angled pull
( b > 30)
80% Fperm
[t]
Erection
TPA-FE
[mm]
TPA-FA
[mm]
700
90
100
1,4
1,1
800
120
120
2,5
2,0
1,3
270
950
140
150
4,0
3,2
2,0
2,5
50% Fperm
[t]
0,7
290
1000
140
160
1200
160
175
5,0
7,5
4,0
320
6,0
3,8
390
1500
200
200
10,0
8,0
5,0
500
1500
240
240
14,0
11,2
7,0
500
1500
300
300
17,0
13,6
8,5
500
1500
360
360
22,0
17,6
11,0
er
0,5 e z
Lw
dia.
h = depends on the
thickness of the unit
90
2,5
5,0
10,0
26,0
Load range
[t]
Erecting reinforcement *
dia. ... x LW
[mm]
1,4
2,5
4,0
5,0
7,5
10,0
dia. 10 x 700
12,5
17,0
22,0
dia. 25 x 1500
dia. 12 x 800
dia. 14 x 950
dia. 16 x 1000
dia. 20 x 1200
dia. 20 x 1500
dia. 25 x 1800
dia. 28 x 1800
For other concrete strength, the length LW of the erecting reinforcement may be reduced in relation to the permissible composite
2
2
stresses (b W = 25 N/mm : x 0,8; b W= 35 N/mm : x 0,65).
25
a
c
FF 7
Designation
Order No.
TPA-FF 0,7-6
0070.07000001
TPA-FF 1,4-6
00002
TPA-FF 2,0-7
TPA-FF 2,5-7
a
[mm]
c
[mm]
e
[mm]
30
30
65
70
65
00003
70
30
70
00004
80
30
10
75
94
a
[mm]
c
[mm]
d
[mm]
e
[mm]
2,5 FR
d
[mm]
Designation
Order No.
TPA-FF 3,0-9
0070.07000005
40
10
90
100
TPA-FF 4,0-11
00006
40
12
110
100
TPA-FF 5,0-12
00007
40
15
125
105
c
[mm]
d
[mm]
e
[mm]
0070.070-
a
[mm]
7,5-17
00009
60
16
170
120
TPA-FF 10,0-20
00010
60
20
200
120
TPA-FF
a
c
Order No.
FF 22
12,5 FR
0070.070-
a
[mm]
c
[mm]
d
[mm]
e
[mm]
TPA-FF 12,5-22
00011
80
16
220
200
TPA-FF 17,0-27
00012
80
20
270
200
TPA-FF 22,0-31
00013
80
26
310
200
Order No.
How to order
Selected anchor:
Type
Load range
Anchor length in cm
TPA-FF 4,0 - 11
Order No.: 0070.070-00006
[t]
Load group
Cover to
k
Anchor head [mm]
26
2,5 t
5,0 t
10,0 t
26,0 t
10
10
15
15
t=d+k+
Reinforcement steel *
12,5 FR
FF 22
z
L
dia.
[t]
[t]
2,5
0,7
1,4
2,0
2,5
5,0
10,0
26,0
3,0
4,0
5,0
7,5
10,0
12,5
17,0
26,0
Designation
t
[mm]
er
[mm]
ez
[mm]
65
80
140
280
65
80
140
280
70
90
150
300
d
[mm]
TPA-FF
TPA-FF
TPA-FF
TPA-FF
TPA-FF
TPA-FF
TPA-FF
0,7 - 6
1,4 - 6
2,0 - 7
2,5 - 7
3,0 - 9
4,0 - 11
5,0 - 12
TPA-FF 7,5 - 17
TPA-FF 10,0 - 20
TPA-FF 12,5 - 22
TPA-FF 17,0 - 27
TPA-FF 22,0 - 31
Perm. loads
Axial angled and transversal pull
at concrete strength bw when lifted:
L
[mm]
15 N/mm 2
[t]
200
0,7
0,7
250
1,4
1,4
1,4
300
1,8
2,0
2,0
dia.
[mm]
25 N/mm
[t]
30 N/mm
[t]
0,7
75
100
160
320
300
2,0
2,5
2,5
90
120
190
380
10
400
2,8
3,0
3,0
110
140
230
460
12
450
3,7
4,0
4,0
125
160
260
520
12
500
4,4
5,0
5,0
170
215
340
680
14
600
5,46
7,0
200
245
400
800
14
600
7,55
10,0
10,0
220
265
440
880
16
750
8,85
12,5
12,5
270
315
540
1080
16
900
12,03
17,0
17,0
310
355
620
1240
20
1100
14,80
22,0
22,0
7,5
27
Order No.
TPA-FP 1,4-5
0070.05000001
TPA-FP 2,5-8
00002
a
[mm]
c
[mm]
d
[mm]
e
[mm]
f
[mm]
30
55
80
30
10
80
80
a
[mm]
c
[mm]
d
[mm]
e
[mm]
f
[mm]
40
15
120
100
10
a
[mm]
c
[mm]
d
[mm]
e
[mm]
f
[mm]
60
20
160
140
12
Order No.
0070.05000003
TPA-FP 5,0-12
k
Load group 10,0 t (7,5 t - 10,0 t)
2,5 t
5,0 t
10,0 t
10
10
15
Designation
Order No.
TPA-FP 10-16
0070.05000004
Load capacity, installation dimensions, additional reinforcement for thin slabs and pipes
Concrete strength b W 15 N/mm
Load Load
group range
Designation
[t]
[t]
2,5
1,4
2,5
TPA-FP 1,4 - 5
TPA-FP 2,5 - 8
5,0
10,0
TPA-FP 5,0 - 12
TPA-FP 10,0 - 16
5,0
10,0
d
[mm]
er
[mm]
ez
[mm]
[mm]
L
[mm]
55
115
230
200
1,12
1,4
80
165
330
10
300
2,0
2,5
120
240
480
12
450
4,0
5,0
160
330
660
16
600
8,0
10,0
t=d+k+
d = Anchor length
k = Cover to anchor head
= Concrete cover acc. to DIN 1045
28
e
e
z
Reinforcement steel *
dia.
k1
5,0
10
TPA-FG 4,0-7
0070.06000001
a
[mm]
c
[mm]
d
[mm]
e
[mm]
f
[mm]
60
16
67
150
Subject to alteration
Load
range
[t]
[t]
5,0
4,0
Designation
TPA-FG 4,0 - 7
Additional reinforcement *
d
[mm]
er
[mm]
ez
[mm]
dia.
[mm]
67
240
480
12
Permissible load
L
[mm]
450
4,0
b = cable angle,
when b < 45 see hints above
t=d+k+
d = Anchor length
k = Cover to anchor head
= Concrete cover acc. to DIN 1045
t
dia.
e
r
e
z
e
r
Reinforcement steel *
29
TPA-FD 2,5-33
00003
[mm]
[mm]
250
30
10
228
300
30
10
278
350
30
10
328
a
[mm]
c
[mm]
d
[mm]
40
15
226
TPA-FD 5,0-28
00005
300
40
15
276
TPA-FD 5,0-33
00006
350
40
15
326
TPA-FD 5,0-38
00007
400
40
15
376
TPA-FD 5,0-43
00008
450
40
15
426
TPA-FD 5,0-48
00009
500
40
15
476
How to order:
Selected anchor:
[mm]
[mm]
[mm]
60
16
262
60
16
312
60
16
362
TPA-FD 7,5-41
00013
450
60
16
412
TPA-FD 7,5-46
00014
500
60
16
462
TPA-FD 10,0-26
00015
300
60
20
262
TPA-FD 10,0-31
00016
350
60
20
312
TPA-FD 5,0 - 38
TPA-FD 10,0-36
00017
400
60
20
362
TPA-FD 10,0-41
00018
450
60
20
412
TPA-FD 10,0-46
00019
500
60
20
462
a
[mm]
c
[mm]
d
[mm]
400
80
16
362
450
80
16
412
Type
Load range
Anchor length in cm
0070.08000020
TPA-FD 12,5-36
00021
TPA-FD 12,5-41
Load group
[t]
2,5 t
5,0 t
10,0 t
26,0 t
Cover to
anchor head
k
[mm]
10
10
15
15
30
TPA-FD 12,5-46
00022
500
80
16
462
TPA-FD 17,0-36
00023
400
80
20
362
TPA-FD 17,0-41
00024
450
80
20
412
TPA-FD 17,0-46
00025
500
80
20
462
TPA-FD 22,0-41
00026
450
80
26
412
TPA-FD 22,0-46
00027
500
80
26
462
TPA-FD 22,0-56
00028
600
80
26
562
Load
group
Designation
5,0
10,0
2 x dia z ...L
26,0
Permissible
column weight
for b W
2
25 N/mm
[t]
[mm]
[mm]
for b W
15 N/mm 2
[t]
TPA - FD 2,5 - 23
12
750
4,0
5,0
TPA - FD
TPA - FD
TPA - FD
TPA - FD
TPA - FD
TPA - FD
TPA - FD
12
750
4,0
5,0
12
750
4,0
5,0
16
1000
8,0
10,0
16
1000
8,0
10,0
16
1000
8,0
10,0
16
1000
8,0
10,0
16
1000
8,0
10,0
TPA - FD 5,0 - 48
TPA - FD 7,5 - 27
TPA - FD 7,5 - 32
TPA - FD 7,5 - 36
TPA - FD 7,5 - 41
TPA - FD 7,5 - 46
TPA - FD 10,0 - 26
16
1000
8,0
10,0
20
1200
12,0
15,0
20
1200
12,0
15,0
20
1200
12,0
15,0
20
1200
12,0
15,0
20
1200
12,0
15,0
25
1500
16,0
20,0
TPA - FD 10,0 - 31
TPA - FD 10,0 - 36
TPA - FD 10,0 - 41
TPA - FD 10,0 - 46
TPA - FD 12,5 - 36
TPA - FD 12,5 - 41
TPA - FD 12,5 - 46
25
1500
16,0
20,0
25
1500
16,0
20,0
25
1500
16,0
20,0
25
1500
16,0
20,0
25
1500
20,0
25,0
25
1500
20,0
25,0
25
1500
20,0
25,0
TPA - FD 17,0 - 36
TPA - FD 17,0 - 41
TPA - FD 17,0 - 46
TPA - FD 22,0 - 41
TPA - FD 22,0 - 46
TPA - FD 22,0 - 56
28
1600
27,2
34,0
28
1600
27,2
34,0
28
1600
27,2
34,0
28
2000
35,2
44,0
28
2000
35,2
44,0
28
2000
35,2
44,0
[t]
2,5
Reinforcement
2,5 - 28
2,5 - 33
5,0 - 23
5,0 - 28
5,0 - 33
5,0 - 38
5,0 - 43
dia.z
Base of column
Erecting
Column
width-
er
Note:
the larger the dimension er, the greater the load on the
anchor when erecting, but the lower the load on the edge
at the base of the column.
31
2 x er
FH** FV
Additional reinforcement 1 **
(not supplied by HALFEN)
h1
dia.1**
90
dia.1
Reinforcing steel *
L w =Length before bending
h 1 Acc. to thickness of element,
but at least as per table below
** Only required if FH exists,
e.g. when positive production
Additional reinforcement 2
(not supplied by HALFEN)
dia. 2
How to order:
Selected anchor:
Type
Load range
Anchor length in cm
Version
TPA-FX 5,0 - 30 - fv
Order No.:
0070.090-00007
Reinforcing steel *
30
l2
dia.2
Bending radius
acc. to DIN 1045
2,5
0,8
5,0
5,0
1,8
10,0
7,5
2,6
10,0
10,0
3,5
26,0
17,0
5,0
Load group
Designation
5,0
10,0
10,0
26,0
TPA-FX 5,0-30
TPA-FX 7,5-35
TPA-FX 10,0-35
TPA-FX 17,0-40
[mm]
[mm]
[mm]
[mm]
n dia. ...x L1
[mm]
250
10
10
100
2 dia. 8 x
600
60
300
16
18
120
2 dia. 8 x
800
00003
00008
80
350
16
26
130
2 dia. 10 x 800
00004
00009
80
350
20
26
140
4 dia. 10 x 800
00005
00010
100
400
20
35
180
4 dia. 12 x 1200
Additional reinforcement 1 * 1
Lw
h1
[mm]
[mm]
[mm]
TPA-FX 2,5-25
TPA-FX 5,0-30
TPA-FX 7,5-35
10
600
14
700
16
800
TPA-FX 10,0-35
TPA-FX 17,0-40
20
20
Additional reinforcement 2 *
Cut length
dia.2
l2
[mm]
Recommended
recess former
[mm]
60
14
800
TPA-A1 2,5
80
16
1200
TPA-A1 5,0
100
120
25
1400
TPA-A1 10,0
900
25
1800
TPA-A1 10,0
1100
140
28
2500
TPA-A1 26,0
32
00007
b2
00002
dia. 1
[t]
2,5
Finish:
a
black
hot-dip-galv. (fv)
Order No.
Order No.
[mm]
0070.0900070.09000006
00001
40
TPA-FX 2,5-25
Designation
All dimensions in mm
Subject to alteration
[t]
1,25
1
TPA-FU 1,25 - 12
Order
No.
0070.
100-
er
ez
[mm] [mm]
00001
30
[t]
[t]
[t]
240 1,25
1,0
0,65
Recommended reinforcement
An additional reinforcement tail as in
the drawing on the left is essential for
distributing the loads in very thin
panels or on ones with only a singlelayer reinforcement.
For turning and erecting, a turning
reinforcement as shown below must
be incorporated.
Reinforcement steel *
dia. 8, cut length 700 mm
e
z
spac
ing t
o the
next
anch
or
33
ANCHOR INSTALLATION
General Instructions
Floating installation
Installation aid:
Holding plate H1
Nail or screw the holding
plate H1 4 onto the formwork. Press on the recess
former A1 2 with inserted
anchor 1 .
4
34
Installation aid:
Holding bold S1 or S2
Installation aid:
Magnetic holding plate HM
RECESS FORMERS
Types TPA-A1, TPA-A2, TPA-A3
Installation:
Special
attributes:
Plastic
for Spread-, Two hole-, Plate-, Flat foot-,
Columns-, Erection-, Sandwich panelanchor
Holding plate H1, H2, H4, HM;
Holding bold S1 or S2
High durability and good resistance
against formwork release oil.
Load group
2,5 t
Designation
Order No.
TPA-A1 2,5
0072.010-
a [mm]
b [mm]
c [mm]
d [mm]
Colour
5,0 t
10,0 t
26,0 t
00001
00002
00003
00004
43
49
67
112
104
126
188
234
45
59
85
118
M8
M8
M 12
M 16
Orange
Black
Green
Blue
Rubber
for all anchors except erection and garage
anchors
by holding bold or holding plate H3
2,5 t
5,0 t
10,0 t
TPA-A2 2,5 TPA-A2 5,0 TPA-A2 10,0
Order No.
0072.020-
a [mm]
b [mm]
c [mm]
00001
00002
41
51
00003
70
102
126
184
47
59
84
Material:
Application:
Installation:
Load group
Designation
Rubber
for garage anchors
by locking bracket
5,0 t
TPA-A3 5,0
Order No.
0072.030-
00001
a [mm]
b [mm]
115
c [mm]
50
54
Subject to alteration
35
RECESS FORMERS
Types TPA-A4, TPA-A5 and accessories
2,5 t
5,0 t
TPA-A4 2,5
TPA-A4 5,0
00001
00002
0072.040-
a [mm]
b [mm]
c [mm]
d [mm]
Colour
10,0 t
26,0 t
00004
112
37
48
70
102
126
184
252
45
59
84
118
M8
M8
M 12
M 16
Orange
Black
Green
Blue
TPA-A Z01
(foam)
Load group
Designation
Order No.
2,5 t
5,0 t
TPA-A5 2,5
TPA-A5 5,0
00001
0072.050-
10,0 t
26,0 t
00002
00003
00004
a [mm]
b [mm]
c [mm]
37
48
70
112
102
126
184
252
45
59
85
118
d [mm]
M8
M8
M 12
M 16
Load group
Designation
2,5 t
00006
Load group
Designation
Order No.
2,5 t
00002
10,0 t
26,0 t
00005
0072.1205,0 t
10,0 t
26,0 t
00007
00008
00009
Subject to alteration
36
00003
00004
RECESS FORMERS
Types TPA-A7, TPA-A8 and TPA-A9
Plastic
Universal anchor TPA-FU
by holding plate H1
only for load group 1,25 t
1,25 t
TPA-A7 1,25
Order No.
0072.070-
a [mm]
b [mm]
c [mm]
00001
25
60
32
Note:
Load group
Designation
Order No.
0072.080-
Plastic
for anchors of load group 2,5 t
The TPA-A8 former consists of two
sections which are pushed together over
the anchor head and then secured to the
mould by means of a wedge that is
pushed through the two fixing tabs
Not reusable!
2,5 t
TPA-A8 2,5
00001
Installation:
Note:
Load group
Designation
Plastic
especially suitable for TPA-FS, TPA-FZ,
TPA- FF and TPA-FD, not suitable for
TPA-FA, TPA-FE and TPA-FX
as TPA-A1
for recesses without protruding concrete
lugs.
2,5 t
TPA-A9 2,5
5,0 t
10,0 t
26,0 t
Order No.
0072.090-
a
b
c
d
00001
00002
00003
[mm]
43
49
67
00004
112
[mm]
104
126
188
234
[mm]
45
59
85
118
[mm]
M8
M8
M 12
M 16
Orange
Black
Green
Blue
Colour
Subject to alteration
37
ANCHOR INSTALlATION
Holding plates for recess formers
(Version 1,25 t)
Load
Designation Order No.
group [t]
0073.0101,25
TPA-H1 1,25 00001
2,5
TPA-H1 2,5 00002
TPA-H1 5,0 00003
5,0
10,0
26,0
TPA-H1 10,0
TPA-H1 26,0
[mm]
[mm]
[mm]
[mm]
40
15
70
15
10
10
85
30
00004
125
45
12
00005
175
65
16
TPA-H2 10,0
TPA-H2 26,0
[mm]
[mm]
[mm]
[mm]
70
15
10
85
30
10
00003
125
45
12
00004
175
65
16
[mm]
[mm]
[mm]
[mm]
100
50
120
60
170
80
12
[mm]
[mm]
[mm]
[mm]
144
63
16
10
144
63
16
10
200
80
16
12
Subject to alteration
38
ANCHOR INSTALLATION
Holding plates and holding bolts for recess formers
[mm]
[mm]
[mm]
[mm]
144
63
16
10
144
63
16
10
dia.
Order No.
dia.
0073.060-
[mm]
[mm]
TPA-S1- M8
00001
160
M8
TPA-S1- M8
TPA-S1-M12
TPA-S1-M16
00002
160
M8
00003
160
M 12
00004
180
M 16
Load group
[t]
Designation
2,5
5,0
10,0
26,0
dia.
Load group
[t]
Designation
2,5
TPA-S2- M8
TPA-S2- M8
TPA-S2-M12
TPA-S2-M12
5,0
10,0
26,0
Order No.
dia.
0073.070-
[mm]
[mm]
[mm]
00001
160
11
M8
00001
160
11
M8
00002
180
16
M 12
00002
180
16
M 12
Subject to alteration
39
ACCESSORIES
Recess filler TPA-V1 / Cover plate TPA-V2 for anchor recess
Recess filler TPA-V1
(Polystyrene)
Order No.
0073.080-
2,5 t
TPA-V1 2,5
00001
5,0 t
TPA-V1 5,0
00002
10,0 t
TPA-V1 10,0
00003
26,0 t
TPA-V1 26,0
00004
Load group
[t]
Designation
2,5 t - 5,0 t
00001
150
70
TPA-V2 10,0
00002
260
130
10,0 t
Order No.
a [mm]
b [mm]
0073.090-
Subject to alteration
40
Assembly
To transport an element, the appropriate ring clutch for the load group is
inserted over the anchor head in the
concrete recess. The load ranges are
mismatch-proof.
A
A
3, 0
Z
-5
,0
-5
,0 t
0
3,
90
A
Z
-5
,0 t
0
3,
41
RING CLUTCHES
Ring clutch TPA-R1 with shackle for manual release
Corresponding
load ranges [t]
a [mm]
b [mm]
c [mm]
d [mm]
e [mm]
26,0 t
2,5 t
5,0 t
10,0 t
TPA-R1 2,5 TPA-R1 5,0 TPA-R1 10,0 TPA-R1 26,0
00001
00002
00003
00004
0,7 - 2,5
3,0 - 5,0
5,3 - 10,0
12,5 - 26,0
265
330
425
605
27
36
50
72
80
100
140
209
70
86
112
160
50
71
90
120
Production date
The marking of the clutch heads is the
same for all types. It subsists of:
-Quality mark "FRIMEDA"
-Factory code,e.g. "81"
-Load capacity,e.g. "3,0-5,0 t" (Load
group)
Additionally, on the reverse side the
position of the locking bolt is signed
"A - Z" ("open - close").
The quality mark (F), the type designation (e.g. R1) and production date
(month/year) are imprinted on the
shackle (Type R1, F1 and F2) alternatively, on the aluminium clips of the
cable wires (Type R2 und R3). Example: "F - R1 - 10/93".
The ring clutches are clearly matched
to the anchors by compatible design
as well as by marking the anchor types
and load groups. Only matching
components will fit together.
Type
FRIMEDA Quality mark
Shackle
FRIMEDA
Quality mark
Clutch head
Locking bolt
Factory code
Note
The values for load groups and load
ranges are given in metric tons [t].
1 t is equivalent to 10 kN.
42
Subject to alteration
RING CLUTCHES
Ring clutch TPA-R2 / TPA-R3 with wire cables for manual release
Checking:
Note:
The clutch head and the locking bolt
are the same as for type TPA-R1.
1,25 t
TPA - R2 1,25
2,5 t
TPA - R2 2,5
00001
00002
1,25
0,7 - 2,5
60
50
5,0 t
TPA - R2 5,0
26,0 t
TPA - R3 26,0
00004
00005
3,0 - 5,0
5,3 - 10,0
12,5 - 26,0
120
200
240
1570
90
100
140
160
210
195
295
325
480
dia. 8
dia. 14
dia. 18
dia. 22
dia. 32
00003
10,0 t
TPA - R2 10,0
Subject to alteration
43
RING CLUTCHES
Ring clutch TPA-F1 with pneumatic remote-control release
Operating principle
Operating sequence
00001
00002
00003
00004
Subject to alteration
44
RING CLUTCHES
Accessories for TPA-F1
11
12
Single lift
11
12
11
11
11
12
Double lift
11
12
12
11
11
6
1
10
12
No.
Four-point lift
Designation
12
Order No.
0071.070-
Single lift
Four-point lift
see page 44
Hand valve
Key
Compressor
Quick-action hose coupling R 1/4"
As No. 5, but for hose on both sides
Thread plug R 1/4"
Coupling R 3/8"
00004
00005
00011
00002
00010
00003
00014
Coupling R 1/4"
4-way distributor
Hose clip
Fabric hose
00015
00001
00012
10
20
00013
As requested
As requested
As requested
3
4
5
6
7
8
9
10
11
12
45
RING CLUTCHES
TPA-F2 mit manual remote control by Bowden cable
Operating princple
The remote-control release disengages
the ring clutch from a safe distance of
up to 10 metres. The release mechanism consists basically of a Bowden
cable connected to the locking bolt of
the ring clutch. At the opposite end,
the release handle is locked in a tube
by means of a safety hook. All TPA-F2
clutch heads in the various load
groups have the same M27 thread,
i.e. the remote-control mechanism fits
any clutch head. The opening and
closing mechanism, comprising the
locking bolt, the shackle with indicator and the slide, are parts of the
complete clutch head.
The flexible tube can withstand reasonable tension and compression loads,
so that the precast unit can easily be
handled. The ring clutches of all the
load groups can be used with any of
the manual remote-control releases of
lengths 2.5 m, 5.0 m, 7.5 m and
10.0m.
2,5 t
5,0 t
10,0 t
26,0 t
Designation
Cable length
TPA-F2 2,5
2,5 m
00001
00005
00009
00013
5,0 m
00002
00006
00010
00014
7,5 m
00003
00007
00011
00015
10,0 m
00004
00008
00012
00016
Subject to alteration
46
RING CLUTCHES
Component parts for TPA-F2
Designation
[t]
2,5
5,0
10,0
26,0
3
TPA-F2-KUP- 2,5
TPA-F2-KUP- 5,0
TPA-F2-KUP-10,0
TPA-F2-KUP-26,0
Order No.
Length
0071.08000001
[m]
00002
5,0
00003
7,5
00004
10,0
2,5
Designation
TPA-F2-SZE- 2,5
TPA-F2-SZE- 5,0
TPS-F2-SZE- 7,5
TPS-F2-SZE-10,0
Order No.
0071.08000005
00006
00007
00008
Designation
[t]
all
Load groups
Order No.
0071.080-
TPA-F2-GRI
00009
Subject to alteration
47
RING CLUTCH
Application / Misuse
1. Engaging
2. Lifting
3. Releasing
Open
locking bolt
Close
locking bolt
Lift out
Insert
rce
Dircetion of fo
No
Permissible
Shackle locks in
this position
Yes
Shackle cannot lock
in this position
48
RING CLUTCHES
Checking lifting devices / spare parts
In common with all lifting devices, the operating safety of ring clutches must be checked at least once a year by an expert for
an operational safety. There is no fixed time period for the withdrawal from use of a FRIMEDA Ring clutch. Any deformation
of a locking bolt means that an overload of at least three times the permitted load has occurred. Worn locking bolts can be
exchanged; no other repairs are permitted. We explicitly warn against the mixing of different companys products. The integrity of the wire ring clutch can only be guaranteed when using the original wire cables or approved replacements installed by
HALFEN. To check FRIMEDA Ring clutches the following criterions have to be observed:
Locking bolt
Clutch head
Load group
[t]
1,25
2,5
5,0
10,0
26,0
Nominal
dimension d
Minimum
dimension d
[mm]
[mm]
8 +0,4/-0,6
13 +0,7/-0,4
16,5 +0,7/-0,4
23,5 +0,8/-0,4
32 +0,9/-0,5
7
12
Load group
[t]
15,5
1,25
22,5
2,5
31
Nominal
dimension e
Maximum
dimension e
[mm]
[mm]
7 0,12
12 0,5
18 + 0,5/-1,0
22 0,5
34 + 2,0/-1,0
5,0
10,0
26,0
8
13,5
19,5
23,5
37
Designation
00002
00003
00004
00005
Designation
[t]
10,0
TPA-F-ERE- 2,5
TPA-F-ERE- 5,0
TPA-F-ERE-10,0
26,0
TPA-F-ERE-26,0
2,5
5,0
Order No.
0071.06000001
TPA-R-E1- 1,25
TPA-R-E1- 2,5
TPA-R-E1- 5,0
TPA-R-E1-10,0
TPA-R-E1-26,0
Cable type
Order No.
0071
.06000006
Shackle (TPA-R1)
d = cable diameter
Load group
Nominal
dimension f
Minimum
dimension f
[t]
[mm]
[mm]
2,5
14
20
26
40
5,0
10,0
26,0
13
19
25
38,5
00007
00008
00009
49
Date of order:
Customer:
Account No.:
Item Quantity
Designation
Order No.
50
Version
Remarks
CONTACT
HALFEN-DEHA Worldwide
Phone:
Fax:
[email protected]
e-Mail:
Internet: www.halfen-deha.com
INTERNET
www.halfen-deha.com
The HALFEN-DEHA Quality Management System is certified for the locations in Gemany, Switzerland
and Poznan (Poland) according to DIN EN ISO 9001/2000, Certificate No. QS-281 HH.