Control Performance Analyzer 3.0
Control Performance Analyzer is used for:
- Setup
- Operation
- Monitoring
- Diagnostics
- Graphical illustration of the pressure behavior
- Programming and recording of sequences
- Several possibilities for data analysis and process optimization
Imprint
VAT Vakuumventile AG 2012
No part of these Instructions may be reproduced in any way (photo copies, microfilms or any other reproduction
processes) nor may it be manipulated with electronic systems, duplicated or distributed without written permission
from VAT. Offenders are liable to pay damages.
The original VAT firmware and updated state of the art versions of the VAT firmware are intended for use with VAT
products. The VAT firmware contains a limited, time unlimited user license. The VAT firmware may not be used for
purposes other than those intended nor is it permitted to make copies of the VAT firmware. In particular, it is strictly
forbidden to give copies of the VAT firmware to other people.
The use of trade names, brand names, trademarks, etc. in these Instructions does not entitle third parties to consider
these names to be unprotected and to use them freely. This is in accordance with the meaning of the laws and acts
covering brand names and trademarks.
Printed: October, 2012
Publisher
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Production
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Control Performance Analyser 3.0
Table of Contents
Foreword
Part I Introduction
1 Use...................................................................................................................................
of product
6
2 Technical
...................................................................................................................................
data
7
Part II Installation
1 Installation
...................................................................................................................................
onto your PC
9
2 Start
...................................................................................................................................
Installation procedure
9
Part III General
13
1 Connect
...................................................................................................................................
Valve to PC
13
2 Start
...................................................................................................................................
up
14
3 Port
...................................................................................................................................
Selection
15
Connect
..........................................................................................................................................................
CPA to VAT valve
15
Stand
..........................................................................................................................................................
alone operation
16
4 Main
...................................................................................................................................
screen of Control Performance Analyser
17
5 CPA
...................................................................................................................................
status bar
18
6 Explanation
...................................................................................................................................
of Button (window top bar)
19
7 Basic
...................................................................................................................................
functions use LOCAL MODE
20
Part IV Help
22
1 Visit
...................................................................................................................................
VAT
22
2 Spare
...................................................................................................................................
parts
22
Index
2012 by VAT Vak uumventile AG, Switzerland
Top Level Intro
This page is printed before a new
top-level chapter starts
Part
Control Performance Analyser 3.0
Introduction
Version
3.0
1.1
Release
1.0.6
Use of product
Use this product for computers operated by a Windows OS operating system. This software can
be operated on following systems:
Windows XP Pro + home
Windows Vista Pro + home
Windows 7 Pro + home
This software provides control functions for these VAT-control valves, which are equipped by a
integrated controller.
Series 61.2 (Series 95.1 and 95.2)
Series 61.5
Series 64.2
Series 65.0
Series 65.1
Series 65.2
Using this software, basic functions like setup of controller, open valve, close valve, learn,
up- download of learned data can be executed, and many convenient functions like monitoring
pressure/position, analysis of pressure control performance, communication monitor, etc) are
available.
2012 by VAT Vak uumventile AG, Switzerland
Introduction
1.2
Technical data
This CPA software requires:
500 MB diskspace
512 MB RAM
RS232 serial port or USB-to-RS232 Converters / PCMCIA Cards
1024x768 minimum resolution for the display
Administrator rights for your PC when you are using Windows-XP; Windows-Vista or
Windows-7
Service cable refer to: Connect Valve to PC
This software has a self-detecting function which recognizes the type of the connected valve.
According to this information, corresponding functions, screens and menus are provided.
2012 by VAT Vak uumventile AG, Switzerland
Top Level Intro
This page is printed before a new
top-level chapter starts
Part
II
Installation
Installation
Control Performance Analyzer is available as download form VAT homepage:
http://www.vatvalve.com/customer-service/informations-and-downloads/control-performanceanalyzer
Note: Save the Zip file CPA and the CPA Installation Instruction on your PC.
2.1
Installation onto your PC
Note: This software can only be installed, if the logged-on user owns Administrator privileges.
If your operating system is a Windows NT, XP, Vista or 7 professional or home, you must have
administrator privileges in order to install this software.
If you are not able to install this program, please contact your System Administrator or Help Desk.
2.2
Start Installation procedure
1. "Unzip" the CPA
2. Double-Click the folder
3. Double-Click the icon setup
After the install-program has been started, following dialog is displayed:
4. Select the primary installation directory.
5. Click the button [Next]...
2012 by VAT Vak uumventile AG, Switzerland
10
Control Performance Analyser 3.0
6. Click the button [Next] to begin installation
7. Wait until "Overall Progress is 100% Complete"
8. Click the button [Next]
2012 by VAT Vak uumventile AG, Switzerland
Installation
9. Click the button [Finish]
10. If this screen appears click the button [Restart] otherwise proceed with step 11.
After restart of your computer the Control Performance Analyzer is ready for use.
11. Connect your valve to the PC as described in Connect Valve to PC
2012 by VAT Vak uumventile AG, Switzerland
11
Top Level Intro
This page is printed before a new
top-level chapter starts
Part
III
General
13
General
Note:
The CPA 3.0 displays always the connected valve automatically.
All window screen-shoots in this "Operating Manual" are examples!
The windows of your installed CPA 3.0 depend to the connected valve and the installed valve
firmware.
The manual of CPA 3.0 you will find in CPA 3.0 folder: Help > Operating Manual
or in CPA 3.0 Status bar. Click [?] to open the Operating Manual.
3.1
Connect Valve to PC
Introducing
Connect the valve to your PC via a 'COM port', 'USB to RS232 converter' or 'Express card to
RS232'. Use the supplied service cable, see in chapter: Spare parts. The maximum cable length
is 10m.
Connection overview
Note: If there is no RS232 port available on your computer, please use a 'USB to RS232 converter'
or 'Express card to RS232' converter. Please use a converter that is supported by your PC and
install the corresponding driver for the used converter.
2012 by VAT Vak uumventile AG, Switzerland
14
3.2
Control Performance Analyser 3.0
Start up
Introducing
Check whether the PC is connected via the service port to your valve. Make sure, that the valve is
supplied by 24VDC (see cable to connector marked Power). The display on the valve shows the
version number for a short time and than the letters C and 0, after self test is finished.
You need not do any adjustments for the RS232 port in advance. Setup of the RS232-port for the
PC is done automatically by Control Performance Analyzer Software.
1. Start the program on your Start-menu > All Programs > VAT Vacuum Valves >
2. After startup is finished, the Control Performance Analyzer displays it startup- screen. (example
see below)
3. Proceed with: Connect CPA to VAT valve
Note: Control Performance Analyzer check which valve is connected to the PC.
According to the type of valve (S61.2, S65IC, S65.1 etc.), slightly different screens and menus are
displayed.
All necessary functions are provided to setup the valve and controller. Parameters are stored to the
valve permanently.
2012 by VAT Vak uumventile AG, Switzerland
General
3.3
15
Port Selection
Introducing
With this function it is possible to change the 'Software Mode'. (Connected to VAT valve or StandAlone Operation)
3.3.1
Connect CPA to VAT valve
1. In Software Mode select [Connect to VAT valve]
2. Click [Enter CPA]
Note: The "Control Performance Analyzer" is now ready for "Normal operation" use.
Refer to: Basic functions use LOCAL MODE.
2012 by VAT Vak uumventile AG, Switzerland
16
3.3.2
Control Performance Analyser 3.0
Stand alone operation
Introducing
In this operation mode it is possible to 'Load' existing data from PC to CPA for checking only. No
valve is connected to CPA in this operation mode.
1. In Software Mode select [Stand-Alone Operation]
2. Click [Enter CPA]
Note: The "Control Performance Analyzer" is now ready for "Stand-Alone Operation" use.
Example:
2012 by VAT Vak uumventile AG, Switzerland
General
3.4
Main screen of Control Performance Analyser
Overview:
Area Description Function
A
top bar
REMOTE / LOCAL
Port Selection
Version - Release
B
navigation explorer menus, adjustment and control
C
E
valve status display the valve status
position
monitor, open, close, hold, adjust and save position setpoint
pressure
monitor, adjust and save pressure setpoint
chart
record / analyze position and pressure in time
status bar
display com port, connected valve, connection status and scan-rate
2012 by VAT Vak uumventile AG, Switzerland
17
18
3.5
Control Performance Analyser 3.0
CPA status bar
Introducing
There are two possible status of CPA. These are described in status bar on bottom of main screen.
Connected to VAT valve:
Connected (CPA is connected to valve, communication is OK and operation possible)
Stand-Alone Operation (only CPA without valve):
Disconnected (CPA is not connected to valve, no communication and no operation possible)
2012 by VAT Vak uumventile AG, Switzerland
General
3.6
Explanation of Button (window top bar)
Example window:
Button
Function
Save changed settings to the valve controller
Set to default settings
Reload changed settings from valve controller
Open the Online Help for this window
Esc or
Close the actual window
2012 by VAT Vak uumventile AG, Switzerland
19
20
3.7
Control Performance Analyser 3.0
Basic functions use LOCAL MODE
Introducing
Using the Control Performance Analyzer is only possible, when the valve is the LOCAL Mode.
Click button [LOCAL]
Now the valve can be operated easily via Control Performance Analyzer.
First steps should be [OPEN], [CLOSE] etc.
Note: If "LOCAL operation is finished, please switch back to "REMOTE mode".
Click button [REMOTE]
2012 by VAT Vak uumventile AG, Switzerland
Top Level Intro
This page is printed before a new
top-level chapter starts
Part
IV
22
Control Performance Analyser 3.0
Help
4.1
Visit VAT
http://www.vatvalve.com
4.2
Spare parts
Introducing
For ordering the 'Service cable' please specify the fabrication number of the valve (see label on
valve) when ordering spare parts. This is to ensure that the appropriate spare parts are supplied.
Item
Description
Ordering No.
Service cable 2 m (between computer and valve)
230327
Service cable 10 m (between computer and valve)
246056
For building the service cable by yourself, please use the following drawing.
You need a 5 line cable, 1 piece D-Sub 9pin female, 1 piece HD-Sub 15pin male (3 rows D-Sub).
2012 by VAT Vak uumventile AG, Switzerland
Back Cover