100% found this document useful (2 votes)
538 views2 pages

RSTRENG Report - 08 - 07 - 2015 - 10 - 12 - 14

This document summarizes the results of a pitting corrosion analysis on a section of pipeline. It provides details on the location, date, pipe dimensions, and material properties. Measurements were taken at 25 increments along the 17.6 inch effective length, with pit depths ranging from 0 to 90 mils. Three analysis methods were used to calculate the maximum safe pressure and burst pressure, with results between 587 psi and 1202 psi depending on the method.

Uploaded by

Mustafa Akbar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (2 votes)
538 views2 pages

RSTRENG Report - 08 - 07 - 2015 - 10 - 12 - 14

This document summarizes the results of a pitting corrosion analysis on a section of pipeline. It provides details on the location, date, pipe dimensions, and material properties. Measurements were taken at 25 increments along the 17.6 inch effective length, with pit depths ranging from 0 to 90 mils. Three analysis methods were used to calculate the maximum safe pressure and burst pressure, with results between 587 psi and 1202 psi depending on the method.

Uploaded by

Mustafa Akbar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Location of Pitting: Example - 1

Station: MP - 09887

Date: 08/07/2015

Line ID: Example - 1

Total Length (in):

19.000

Geog. Location (Lat. , Long.):

0,0

Effective Length (in) Start:

1.000

Pipe Outside Diameter (in):

20

Effective Length (in) End:

18.600

Pipe Wall Thickness (in):

0.219

Effective Length (in):

17.600

SMYS (psi):

57500

Effective Area (in):

0.843

F - Design Factor:

0.72

Max. Pit Depth (Mils):

90.000

Modified SMYS (psi):

41400

Max. Depth/Wall Thickness (%): 41.10

P = 2St/D(psi) - Calculated Pressure: 907.000


Established MAOP (psi):

907

RESULTS OF ANALYSIS:
METHOD

Max. Safe Pressure (psi)

Burst Pressure (psi)

RSTRENG - Effective Area

865.000

1202.000

1.33

RSTRENG - 0.85Dl

736.000

1022.000

1.13

ASME B31G

587.000

816.000

0.90

Prepared By: Musthafa Akbar


Approved By:

Created By:

F-Safety (psi)

Location of Pitting: Example - 1


Station: MP - 09887

Date: 08/07/2015

Num.

Increment (in)

Pit Depth (Mils)

Pit Depth (%)

0.00

0.2

50

22.83

31

14.16

1.34

61

27.85

48

21.92

2.62

32

14.61

3.3

62

28.31

4.12

49

22.37

4.13

21

9.59

10

4.8

64

29.22

11

5.8

31

14.16

12

8.3

33

15.07

13

9.6

45

20.55

14

9.65

40

18.26

15

11.5

44

20.09

16

11.7

90

41.10

17

13.3

47

21.46

18

13.7

34

15.53

19

14.7

81

36.99

20

15.6

43

19.63

21

15.8

23

10.50

22

16.6

64

29.22

23

17.4

52

23.74

24

18.6

52

23.74

25

19

0.00

Prepared By: Musthafa Akbar