Location of Pitting: Example - 1
Station: MP - 09887
Date: 08/07/2015
Line ID: Example - 1
Total Length (in):
19.000
Geog. Location (Lat. , Long.):
0,0
Effective Length (in) Start:
1.000
Pipe Outside Diameter (in):
20
Effective Length (in) End:
18.600
Pipe Wall Thickness (in):
0.219
Effective Length (in):
17.600
SMYS (psi):
57500
Effective Area (in):
0.843
F - Design Factor:
0.72
Max. Pit Depth (Mils):
90.000
Modified SMYS (psi):
41400
Max. Depth/Wall Thickness (%): 41.10
P = 2St/D(psi) - Calculated Pressure: 907.000
Established MAOP (psi):
907
RESULTS OF ANALYSIS:
METHOD
Max. Safe Pressure (psi)
Burst Pressure (psi)
RSTRENG - Effective Area
865.000
1202.000
1.33
RSTRENG - 0.85Dl
736.000
1022.000
1.13
ASME B31G
587.000
816.000
0.90
Prepared By: Musthafa Akbar
Approved By:
Created By:
F-Safety (psi)
Location of Pitting: Example - 1
Station: MP - 09887
Date: 08/07/2015
Num.
Increment (in)
Pit Depth (Mils)
Pit Depth (%)
0.00
0.2
50
22.83
31
14.16
1.34
61
27.85
48
21.92
2.62
32
14.61
3.3
62
28.31
4.12
49
22.37
4.13
21
9.59
10
4.8
64
29.22
11
5.8
31
14.16
12
8.3
33
15.07
13
9.6
45
20.55
14
9.65
40
18.26
15
11.5
44
20.09
16
11.7
90
41.10
17
13.3
47
21.46
18
13.7
34
15.53
19
14.7
81
36.99
20
15.6
43
19.63
21
15.8
23
10.50
22
16.6
64
29.22
23
17.4
52
23.74
24
18.6
52
23.74
25
19
0.00
Prepared By: Musthafa Akbar
Approved By:
Created By: