4afe O2sensor Test

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

FI237

MFI AND SFI SYSTEMS

Electronic Control System (Oxygen Sensor (Main))

Oxygen Sensor (Main)


INSPECTION OF OXYGEN SENSOR
1. WARM UP ENGINE
AIIow the engine to warm up to normal operating tem
perature.
2. INSPECT FEEDBACK VOLTAGE
Connect the positive (+) probe of a voltmeter to
terminal VF1 of the data link connector, and negative ()
probe to terminal E1. Perform the test as follows:
Warm up the oxygen sensor with the engine at 2,500 rpm
for approx. 90 seconds.

Replace the ECM.

Connect terminals TE1 and E1 of the data link connector 1.


And maintain engine at 2,500 rpm.

Zero again

After replacing
the oxygen sensor

Check the number of times the voltmeter needle fluctuates in 10 seconds.


8 times
or more

Less than 8 times

Normal

Warm up the oxygen sensor with the engine at 2,500 rpm


for approx. 90 seconds. And maintain engine at 2,500 rpm.

8 times or more
Check the number of times the voltmeter needle
fluctuates in 10 seconds.
Zero
Less than 8 times
Disconnect terminals TE1 and E1 of the data link connector 1.
And maintain engine at 2,500 rpm.

Measure voltage between terminals VF1 and E1.

More then 0 V

Read and record diagnostic trouble codes. (See page FI32, 44 or 50Y

Normal code, code Nos. Malfunction code(s)


21, 25 and 26 ( Ex. code Nos. 21, 25 and 26)
Repair the relevant diagnostic trouble code.

CONTINUED ON PAGE FI238

Zero

FI238
MFI AND SFI SYSTEMS

Electronic Control System (Oxygen Sensor (Main))

CONTINUED FROM PAGE FI237

Repair the relevant diagnostic trouble code.

Malfunction code(s)
(Ex. code Nos. 21, 25 and 26)
Read and record diagnostic trouble codes. (See page FI32, 44 or 50)

Normal code, code Nos.


21, 25 and 26
Disconnect terminals TE1 and E1 of the data link connector 1.
And maintain engine at 2,500 rpm.

Measure voltage between terminals VF1 and E1.

Disconnect the PCV hose.

Measure voltage between terminals VF1 and E1.


More than 0 V
Repair (Over rich)

Disconnect the engine coolant temp. sensor connector and


connect resistor with a resistance of 4 8 k or another coded
engine coolant temp. sensor.

Connect terminals TE1 and E1 of the data link connector 1.

Warm up the oxygen sensor with the engine at 2,500 rpm for
approx. 90 seconds. And maintain engine at 2,500 rpm.

Measure voltage between terminals VF1 and E1.

Replace the oxygen sensor.

Repair (Over lean)

FI239
MFI AND SFI SYSTEMS

Electronic Control System (Oxygen Sensor (Main))

3. (4AFE (Ex. CALIF.) AND 3SGTE)


INSPECT HEATER RESISTANCE OF OXYGEN SENSOR

Using an ohmmeter, measure the resistance between the


terminals +B and HT.
Resistance (Cold): 5.1 6.3 k at 20C (68F)
If the resistance is not as specified, replace the sensor.

SubOxygen Sensor
(5SFE CALIF. only)
INSPECTION OF SUBOXYGEN SENSOR
INSPECT SUBOXYGEN SENSOR
HINT: Inspect it only when code No.27 is displayed.
(a) Cancel diagnostic trouble code. (See page FI43)
(b) Warm up the engine until it reaches normal operat
ing temperature.
(c) (M /T)
Drive for 5 minutes or more between 80 km/h (50
mph) and 100 km/h in 4th or 5th gear.
(A/T)
Drive for 5 minutes or more between 80 km/h (50
mph) and 100 km/h (62 mph) in D position.
(d) Following the conditions in step (c), press fully on
the accelerator pedal for 2 seconds or more.
HINT: Do not exceed 100 km/h (62 mph), or diagnostic
trouble code will be cancelled.
(e) Stop the vehicle and turn the ignition switch OFF.
(f) Carry out steps (b), (c) and (d) again to test accel
eration.
If code No. 27 appears again, check the suboxygen
sensor circuit. If the circuit is normal, replace the sub
oxygen sensor.