SWAS Overview
SWAS Overview
SWAS Overview
An Overview
For over seven decades, Forbes Marshall has been building steam engineering and control instrumentation solutions
that work for process industries. Today we have evolved into a leader in process efficiency and energy conservation
through technology tie-ups and focused investments in manufacturing and research. Our joint ventures with the
world's leading names enable us to deliver quality solutions in more than 20 countries. Forbes Marshall is unique in
having extensive expertise in both steam and control instrumentation. The dual expertise has allowed us to engineer
industry specific systems that focus on energy efficiency and utilities management for diverse sectors such as textiles,
food processing, paper, power, mining, oil and gas, and chemicals.
Our teams consist some of the finest engineers and talent. These highly trained professionals have developed
innovative solutions to better process efficiencies and help save thousands of dollars for our clients. Our business
practices and processes have combined into a singular philosophy of being trusted partners who provide innovative
solutions. It's a philosophy we are proud to live up to.
We have long standing partnerships with some of the best names in the control instrumentation industry such as
Spirax, Arca, Codel, Krohne and Shinkawa, to develop, design and supply innovative solutions for measurement and
monitoring of process parameters. With a combination of specialist knowledge and the latest technology, we provide
products and solutions to achieve optimum efficiency. Our products are a unique combination of hardware and
software that make them reliable and accurate.
Today in power plants, high pressure boilers and steam turbines are under constant attack from erosive and corrosive
elements such as Silica, Sodium, Dissolved Oxygen, Calcium, Chloride and Phosphates. Without accurate measurement
and monitoring, the plant may suffer heavy mechanical damages that can be caused due to imbalance of turbines,
reduced efficiency, deposition on turbine blades, corrosion of steam pipe work and so on.
Our Steam and Water Analysis System (SWAS) is designed to keep you in power. SWAS assures the safety of your
boiler and turbines, by taking along and analsing up to a dozen samples from all the water and steam circuits. In
today's supercritical power plants, sample conditions as high as 600 Degree C and 300 bars are quite common. The
Forbes Marshall SWAS can easily take care of these samples. To protect your equipment our SWAS works in two
stages:
1. Sample Conditioning
2. Sample Analysis
1. Sample Conditioning
The first section of any SWAS is the Sample Conditioning section or the Wet Panel
Enclosed type
Wet Panel
Open frame-free
standing Wet Rack
Here the sample is first cooled in Sample Coolers, de-pressurised in pressure regulators and then fed to various
analyzers while keeping the flow characteristic constant by means of a back pressure regulating device. There are
several safety equipment provided in wet panels, so that the operators feel safe while working with these systems.
LINE - 1
BOILER FEED WATER
SAMPLE INLET
OTHERS
27
FM
01a
01a
BLOWDOWN HEADER
COOLING WATER OUTLET HEADER
COOLING WATER INLET HEADER
5a
5a
4
02
9
DRAIN
6
12
10
T1
TS
15
11
15
P1
AL
13
PS
14
Description
01a
01b
02
04
05a
06
08
09
10
11
12
13
14
15
16
17
22
23
27
*
Ce
Ct
Phe
Pht
Doe
Dot
Hz
Si
Na
16
22
16
23
17
Item No.
19
CE
NA
NOTE :
1. SAMPLE TUBING : 1/4" OD, 16 SWG, ASTM A 213, TP-316, SEAMLESS TUBE
2. BLOWDOWN HEADER (DEFAULT) : 2" NB, ASTM A106, GR.B, SCH-80, PIPE FLANGED TO 2" NB, ANSI B16.5, CLASS 300 R/F
3. COOLING WATER HEADERS (DEFAULT) : 2"NB, ASTM A106, GR.B, SCH.40, PIPE FLANGED TO 2"NB, ANSI B16.5 CLASS 150R/F
4. WASTE DRAIN HEADER (DEFAULT) : 2"NB, ASTM A106,GR.B, SCH. 40 C.S,PIPE FLANGED TO 2"NB, ANSI B16.5, CLASS 150 R/F
5. COOLING WATER PIPING : 3/4"NB, SS304 PIPING
6. SAMPLE INLET CONNECTIONS : BULKHEAD UNION FOR SR.NO.27
Sample Cooler
Forbes Marshall Sample Coolers are coil-in-shell type
contra-flow heat exchangers. Validated by a premier
institute like IIT, we are one of the few sample cooler
manufacturers in the world offering a guaranteed
performance. With in-house test set-up for
performance testing, world-class manufacturing and
welding facilities, we offer one of the most trusted
sample coolers in the power sector. Various options
of coil materials such as Stainless Steel AISI 316,
Monel 400, and Inconel 625 etc are available.
Sight Glass
Forbes Marshall offers Sample Flow Indicator (Sight
Glass) to view the sample flow inside the sample line.
A rotating wheel indicates presence of cooling water.
The sight glass is made of high grade stainless steel.
Sample Filters
Forbes Marshall also manufactures filters required to
ensure particle-free samples. Particles of size up to 40
microns size can be filtered out. Forged stainless steel
body and hexagonal cap help easy cleaning of the
filter element.
Cation Column
The duplex type Cation Conductivity Column is a field
proven Forbes Marshall design. Cation conductivity
measurements are considered to be more reliable
than ordinary conductivity measurements, as this
method ensures elimination of masking effects of
desired chemicals used in treating the water. This
provides a more realistic picture of dissolved
impurities in the sample. The Forbes Marshall Cation
Column is easy to operate, regenerate and maintain.
T0C
AK
SiO2 Cond
CI2
TH
Cond
+
pH Na
SiO2
Na
TOC
pH
MAKE-UP
SiO2 Na
pH
Na+
O2
Na+
O2
Cond
Cond N2H4
Cond
TOC
Na+
CONDENSER
POLISHING PLANT
O2
DE-AERATOR
Cond
FEED PUMP
COOLING
TOWER
O2
RE-HEATER
FEED PUMP
H2
SiO2
Cond N2H4
GENERATOR
HP TURBINES
O2
SUPER
HEATERS
SiO2
SiO2
PO4 pH
Na+
HP
HEATERS
ECONOMIZER
SiO2
SiO2
Cond
DRUM
CONTAINMENT BUILDING
DEMNERALIZATION PLANT
Cond SiO2 Na
H2
DE-AERATOR
O2
WATER SUPPLY
AK
TH
Cond SiO2 Na
Cond
pH
SiO2 N2H4
O2
O2
pH
PO4
PRIMARY
LOOP:PWR
O2
Cond
O2
Cond
SiO2
Na+
pH
N2H4
H2
O2
pH
H2
O2
Turb
Na+
CONDENSOR
Cond
PRESSURIZER
TH
TOC
HP TURBINES
SiO2
Cond
Na+
SiO2
RE-HEATER
LP TURBINES
GENERATOR
H2
O2
H2
RECTOR CORE
COOLING
TOWER
SECONDARY
LOOP:PWR
pH
CI
STEAM GENERATOR
Cond
Cond
H2
FEED PUMP
MAKE-UP
TOC
O2
WASTE GAS DECAY TANKS
TOC Cond Na
O2
pH
CI
pH Analyzer
pH : The steam which goes to the turbines has to be ultra pure. The pH value of the feed water gives direct indication of
alkalinity or acidity of this water. The ultra pure water has pH value of 7. In a steam circuit; it is a normal practice to keep
the pH value of feed water at slightly alkaline levels. This helps in preventing the corrosion of pipe work and other
equipment. Typically dedicated pH analyzers are recommended at following locations in a steam circuit: high pressure
heaters, DM make-up mater, condensate extraction pump discharge.
Features:
Conductivity Analyzer
Conductivity : Conductivity is an important parameter for detecting any contamination of steam in the boiler
circuit. Conductivity of pure water is almost zero (1-2 Siemens). Ingress of any kind of dissolved impurity will
raise conductivity instantly. Thus conductivity is an important parameter for the detection of leakages.
Typical points in the steam circuit where conductivity should be monitored are: superheated steam, drum water,
high pressure heaters, low pressure heaters, condenser, plant effluent, D.M. plant, make-up water to D.M. plant.
Features:
Silica : The presence of Silica in the steam and water circuits of a power generation plant is associated with a
number of problems both in the super heater and turbine sections.
The solubility of silica in steam increases with pressure. Hence there are chances of silica carryover. The presence of
silica in steam can lead to deposition in superheated tubes and on the turbine blades which may lead to loss of
efficiency and turbine blade failure. For proper working of turbines, continuous monitoring of silica is highly
recommended.
Similarly, the monitoring of anion and mixed bed ion exchanges safeguards and optimizes the operation of the
demineralization plant.
Thus the typical points in steam circuits where silica analysis is required are Low Level Silica Measurement in: high
pressure and low pressure turbines, steam, drum (saturated) steam, CEP discharge, make-up water, D M makeup
water and high level Silica measurement in drum water.
Features:
Predictive diagnostic tools, including Hach's
proprietary Prognosys technology.
PROGNOSYS is now available to provide
confidence in instrument readings.
PROGNOSYS will monitor and display the
reliability of instrument measurement values
and identify when upcoming maintenance
tasks are due in an easy-to-read color display.
Grab Sample In and Out features allow quick
analysis of a grab sample poured into the
analyzer, and facilitate easily taking a sample
out of the analyzer to verify in a lab test.
The industry's only pressurised reagent
delivery system eliminates the frequent
maintenance associated with pumps.
5.7 color screen with intuitive user interface
and predictive diagnostics
90 days of continuous runtime.
Dissolved Oxygen : At elevated temperature, dissolved oxygen causes corrosion which may cause puncturing and
failure of piping and components respectively. Dissolved oxygen also promotes electrolytic action between
dissimilar metals causing corrosion and leakage at joints and gaskets. Mechanical deaeration and chemicals
scavenger additives are used to remove the dissolved oxygen. An analytical check of process efficiency, therefore, is
essential. Dissolved oxygen monitoring is imperative in power stations using neutral or combined operating
conditions (pH 7.0-7.5 or 8.0-8.5). The typical points in steam circuit where dissolved oxygen monitoring is required
are deaerator inlet and outlet.
Features:
Hydrazine : Hydrazine is used as oxygen scavenger. So it also maintains feed water alkalinity to prevent acidic
corrosion. It prevents frothing in the boiler and minimizes deposits on metal surfaces. Hydrazine also helps in
maintaining a protective magnetite layer over steel surfaces. Under dosing of hydrazine leads to increased corrosion and
overdosing represents a costly waste. Therefore hydrazine monitoring is extremely important. The typical points in a
steam circuit where hydrazine monitoring is required are: re-heaters, economizer inlet and L.P. heaters.
Features:
Sodium :The presence of Sodium signals contamination with potentially corrosive anions, e.g. chlorides, sulfates etc.
Under conditions of high pressure and temperature, neutral sodium salts exhibit considerable steam solubility. NaCl and
NaOH, in particular, are known to be associated with Stress Corrosion Cracking of boiler and superheater tubes. The
ubiquitous character of sodium in the environment makes it a useful indication to reveal possible Leak conditions
within the circuit, particularly in the condenser section where the measurement of sodium detects cooling-water leaks
with a much higher sensitivity than conductivity measurements. The typical points in a steam circuit where sodium
monitoring is required are. D.M. plant make up water, condensate pump discharge, condenser, drum (saturated)
steam.
Features:
Chiller
Chilled Package
Chilled water is required when the cooling
water available at site is incapable of cooling
the sample to the temperature required by the
analyzers.
If cooling water temperature exceeds 400 Deg
C, the sample temperature would exceeds
450 Deg C , which is higher than the
temperature required by the analyzers. To
bring down the temperature of the sample,
chilled water is required.
A Chiller Package is also required when a
sample is to be cooled at 25 Deg C. Forbes
Marshall manufactures these in our factory and
are the only SWAS manufacturers having this
capability.
Photo Gallery
Photo Gallery
Forbes Marshall is the only SWAS manufacturer with a unique expertise in both Steam
Engineering & Control Instrumentation
Alstom
Lanco Group
Siemens
Jindal Group
Doosan
Essar Group
Tata Group
ABB
Power Machine
BHEL
NTPC
Thermax
Yokogawa
Bechtel
Honeywell Automation
Doc#CIG/0414/200/V1.R1