Re200ge 140909
Re200ge 140909
Re200ge 140909
:
AGENT
SPECIFICAION
OF
PYROELECTRIC PASSIVE
INFRARED SENSOR
MODEL NO.
PART NO.
RE200GE
APPROVED BY
MODEL NO. :
RE200GE
PART NO.
CHECKED BY
DRAWING NO.
DRAWN BY
REV PAGE
1/8
Scope
This specification describes a pyroelectric passive infrared sensor supplied by NIPPON
CERAMIC CO.,LTD.
Type of sensor
Balanced differential(series opposed type.)
Physical configuration
1) Package
2) Element geometry
3) Element orientation
4) Lead configuration
5) Code
:
Lot number is marked on top surface of detector.
To show last one digit of the A.D. year and week of the year of a inspection completion
Nicera Identification code.
Example
Nicera Identification code
26th week
Year 2014
MODEL NO. :
DRAWING NO.
REV PAGE
RE200GE
PART NO.
2/8
2) Operating voltage
: 1 ~ 15 V dc (Rs: 470kohm)
3) Source voltage
4) Signal output
: Min.
2.5 Vp-p
(Typ. 90 mVp-p)
Noise output shall be measured for 20 seconds when connected to the amplifier
of gain 72.5 dB (at 1 Hz) and shut out from Infrared energy.
See Figure 3
6) Balance output
: Max. 15 %
Bo / |SA+SB| 0.15
Bo : Balance output
SA : Signal output on Element A
SB : Signal output on Element B
Balance output is measured at chopper frequency of 1 Hz when connected to the
amplifier of gain 72.5 dB (at 1 Hz) and submitted to the emission of Infrared energy of
13 microW/cm2 from 420 K Black Body.
See Figure 3
7) Frequency response
MODEL NO. :
DRAWING NO.
REV PAGE
RE200GE
PART NO.
3/8
Optical characteristics
1) Field of view
2) Filter substrate
: Silicon
3) Cut on (5 %T ABS)
: 5 (+/-) 1 micron
4) Transmission
: 70 % average 8 to 13 micron
Environmental requirements
1) Operating temperature : -30 degC to +70 degC
2) Storage temperature
3) Relative humidity
The sensor shall operate without increase in noise output when exposed to
90 ~ 95 % RH at 30 degC continuously.
4) Hermetic seal
RoHS compliance
This product conforms to the RoHS Directive in force at the date of issuance of this
Specification Sheet.
MODEL NO. :
DRAWING NO.
REV PAGE
RE200GE
PART NO.
4/8
Configuration (Figure 1)
Field of view
138
125
0
4.
WINDOW
ELEMENT
3.
2. 0
0
(Figure 1-a)
1
1
Top view
(Figure 1-b)
42
6B
9.20.2
8.30.2
Side view
4.50.2
OPTICAL HEIGHT
ELEMENT HEIGHT
13.51.0
3.70.1
3.30.1
(Figure 1-c)
0.453
Base view
(Figure 1-d)
PCD 5.08
45
1: Drain
2: Source
3: Ground
unit : mm
MODEL NO. :
DRAWING NO.
REV PAGE
RE200GE
PART NO.
5/8
VD:5V
1 DRAIN
+
-
(-)
(+)
(+)
(-)
+
-
2 SOURCE
RS:470K
3 GND
SENSOR
MEASUREMENT AMP.
RECORDER
AMP .
REC OR DER
SEN SO R
HEA T SOU RC E
420 K BL AC K B ODY
APE RT URE 1 2m m
CHO PP ER
S HUT TER
:1Hz CHOPPING
OC CL UDE R
Occluder position
OCCLUDER
Signal output
MODEL NO. :
SHUTTER,CHOPPER
OCCLUDER
Balance output
DRAWING NO.
Noise output
REV PAGE
RE200GE
PART NO.
6/8
Notes
1.Design restrictions/precautions
If used for outdoor applications, be sure to apply suitable supplementary optical filter and
drip-proof, anti-dew construction. This sensor is designed for indoor use.
in cases where secondary accidents due to operation failure or malfunctions can be
anticipated, add a fail safe function to the design.
2.Usage restrictions/precautions
To prevent sensor malfunctions, operational failure or any deterioration of its characteristics,
do not use this sensor in the following, or similar, conditions.
a. In rapid environmental temperature changes.
b. In strong shock or vibration.
c. In a place where there are obstructing materials (glass,fog,etc.) Through
which Infrared rays cannot pass within detection area.
d. In fluid, corrosive gases and sea breeze.
e. Continual use in high humidity atmosphere.
f. Exposed to direct sun light or headlights of automobiles.
g. Exposed to direct wind from a heater or air conditioner.
3.Assembly restrictions/precautions
Soldering ______
a. Use soldering irons when soldering.
b. Avoid keeping pins of this sensor hot for a long time as excessive heat may
cause deterioration of its quality.(e.g. within 5 sec. at 350 degC)
Washing ______
a. Be sure to wash out all flux after soldering as remainder may cause malfunctions.
b. Use a brush when washing. Washing with an ultrasonic cleaner may cause operational
failure.
MODEL NO. :
DRAWING NO.
REV PAGE
RE200GE
PART NO.
7/8
MODEL NO. :
DRAWING NO.
REV PAGE
RE200GE
PART NO.
8/8