Multi-Function Measuring Instrument: Testo 435 - The Allrounder For Ventilation and Indoor Air Quality
Multi-Function Measuring Instrument: Testo 435 - The Allrounder For Ventilation and Indoor Air Quality
Multi-Function Measuring Instrument: Testo 435 - The Allrounder For Ventilation and Indoor Air Quality
06.08.2013
14:30
Seite 1
We measure it.
Multi-function
measuring instrument
testo 435 The allrounder for
ventilation and indoor air quality
humidity measurement
Vane and hot wire probes
Integrated differential pressure probe for Pitot tube
m/s
ppm
CO 2
Lux
www.testo.com
testo-435-P02
06.08.2013
14:30
Seite 2
testo 435
We measure it.
Technical data
testo 435-1
testo 435-2
testo 435-3
testo 435-4
-20 to +50 C
Storage temperature
-30 to +70 C
Dimensions
220 x 74 x 46 mm
Battery type
Battery life
Weight
428 g
Housing material
ABS/TPE/Metal
Protection class
IP54
Warranty
2 years
testo-435-P03
06.08.2013
14:31
Seite 3
testo 435
We measure it.
Technical data
Overview of versions testo 435
The table provides a fast overview of the connectable probes and the instrument equipment per version.
Connectable probes (optional)
testo 435-1
testo 435-2
testo 435-3
testo 435-4
IAQ probe for the measurement of CO2, air temperature, indoor air humidity
and absolute pressure
Thermal flow velocity probe with integrated temperature and air humidity
measurement
Ambient CO probe
Instrument equipment
Easy operation with user profiles
Illuminated display
testo 435-1/-2/-3/-4
Sensor types
NTC
Type K (NiCr-Ni)
Type T (Cu-CuNi)
Measuring range
-50 to +150 C
-200 to +1370 C
-200 to +400 C
0 to +100 %RH
Accuracy
1 digit
Resolution
0.1 C
0.1 C
0.1 C
0.1 %RH
Vane
Hot wire
Measuring range
0 to +60 m/s
0 to +20 m/s
0 to +2000 hPa
Accuracy 1 digit
Resolution
0.01 m/s
0.1 hPa
1 ppm CO2
testo 435-2/-4
testo 435-3/-4
Sensor types
Lux
Measuring range
0 to +100000 Lux
0 to +25 hPa
Accuracy
1 digit
Resolution / Overload
1 Lux; 0.1 Hz
testo-435-P04
22.01.2014
13:12
Seite 4
testo 435
We measure it.
Accessories
Part no.
Service case for basic equipment of measuring instrument and probes, dimensions: 400 x 310 x 96 mm
0516 0035
Service case for measuring instrument, probe and accessories, dimensions 520 x 380 x 120 mm
0516 0435
0554 0410
testovent 415, volume flow funnel, 210 mm/210x210 mm, incl. case
0554 0415
testovent 417 funnel set for plate outlets ( 200 mm) and funnel for ventilator (330 x 330 mm) for ingoing and
outgoing air
0563 4170
0554 0440
Connection hose silicone-free for differential pressure measurement, length 5 m, load up to maximum 700 hPa, (mbar)
0554 0453
Control and adjustment set for Testo humidity probes, salt solution with 11.3% RH and 75.3% RH, incl. adapter for
Testo humidity probes, quick checks or calibration of humidity probe
0554 0660
Sintered PTFE filter, 12 mm, for corrosive media, High humidity range (long-term measurements), high flow velocities.
0554 0756
Stainless steel sintered filter, pore size 100 m, probe protection in dusty atmospheres or higher flow velocities
0554 0641
Plug-in mains adapter, 5 VDC 500 mA with European adapter, 100-250 VAC, 50-60 Hz
0554 0447
0515 0028
0554 0761
0554 0549
0554 0568
External fast charger for 1-4 AA rech. batteries, incl. 4 Ni-MH rech. batteries with individual cell charging and charge
control display, incl. impulse trickle charging, integrated discharge function, with built-in international mains plug,
100-240 V, 300 mA, 50/60 Hz
0554 0610
Calibration Certificates
ISO calibration certificate/temperature
meas. instr. with surface probe; calibration points +60C; +120C; +180C
0520 0071
0520 0006
0520 0005
0520 0024
0520 0004
0520 0034
0520 0010
0520 0033
testo-435-P05
06.08.2013
14:33
Seite 5
We measure it.
testo 435
Probes
Probe type
Measuring
range
Accuracy
0 to +50 C
0 to +100 %RH
0 to +10000
ppm CO2
+600 to +1150
hPa
0.3 C
2 %RH (+2 to +98 %RH)
(75 ppm CO2 3% of mv) (0
to +5000 ppm CO2)
(150 ppm CO2 5% of mv)
(+5001 to +10000 ppm CO2)
10 hPa
0632 1535
0 to +500 ppm
CO
5% of mv (+100.1 to +500
ppm CO)
5 ppm CO (0 to +100 ppm CO)
0632 1235
0 to +120 C
Class 1
0602 0743
-20 to +70 C
0 to +100 %RH
0 to +20 m/s
0.3 C
2 %RH (+2 to +98 %RH)
(0.03 m/s +4% of mv)
0635 1535
0635 9535
+0.25 to +20
m/s
0635 9335
0 to +20 m/s
-20 to +70 C
0635 1025
0635 9435
Dimensions
Probe shaft/probe shaft tip
t99
Part no.
Operating
temperature
0 to +60 C
Operating
temperature
0 to +60 C
0563 4170
0554 4172
Flow straigthener set testovent 417 consisting of funnel set testovent 417 and flow straigthener testovent 417
0554 4173
0 to +2000 hPa
5 hPa
0638 1835
testo-435-P06
06.08.2013
14:34
Seite 6
testo 435
We measure it.
Probes
Measuring
range
Accuracy
t99
-50 to +125 C
60 s
0613 1712
-60 to +300 C
Class 2 1)
3s
0602 0393
-60 to +130 C
Class 2 1)
5s
0602 4592
-50 to +100 C
Class 2 1)
5s
0602 4692
-60 to +400 C
Class 2 1)
7s
0602 1293
0 to +50 C
0 to +5 m/s
0.3 C
(0.03 m/s +4% of mv)
0628 0109
0 to 100.000
Lux
0 to 300 Hz
0635 0545
-20 to +70 C
0 to +100 %RH
0.3 C
2 %RH (+2 to +98 %RH)
0636 9735
-20 to +70 C
Class 11)
U-value: 0.1 2% of fsv*
0614 1635
Probe type
Air probes
2)
Dimensions
Probe shaft/probe shaft tip
Part no.
(testo 435-1/-2/-3/-4)
Surface probes
2)
115 mm
50 mm
5 mm
4 mm
(testo 435-1/-2/-3/-4)
Immers./penetr. probes
2)
115 mm
5 mm
12 mm
(testo 435-1/-2/-3/-4)
Waterproof immersion/penetration
probe, TC Type K, Fixed cable 1.2
m
114 mm
50 mm
5 mm
3.7 mm
max. 820 mm
12 mm
Surface probes
2)
(testo 435-2/-4)
Operating temperature
0 to +600 C
0635 2145
0635 2045
0635 2345
testo-435-P07
07.01.2014
10:07
Seite 7
testo 435
We measure it.
Radio probes
Part no.
0613 1001
Radio immersion/penetration probe, NTC, approval for USA, CA, CL; Radio freq. 915.00 MHz FSK
0613 1002
Dimensions
Probe shaft/probe shaft tip
105 mm
30 mm
5 mm
3.4 mm
Measuring
range
Accuracy
Resolution
t99
-50 to +275 C
0.5
0.8
0.8
1.5
0.1 C
t99 (in
water)
12 s
C
C
C
C
(-20 to +80 C)
(-50 to -20.1 C)
(+80.1 to +200 C)
(remaining range)
Part no.
0554 0189
Radio handle for plug-in probe heads, incl. T/C adapter, approval for USA, CA, CL; Radio freq. 915.00 MHz FSK
0554 0191
0602 0293
Dimensions
Probe shaft/probe shaft tip
100 mm
30 mm
5 mm
3,4 mm
Measuring
range
Accuracy
Resolution
t99
-50 to +350 C
Short-term to
+500 C
Radio handle:
(0.5 C +0.3% of m.v.) (-40 to +500 C)
(0.7 C +0.5% of m.v.) (remaining range)
T/C probe head: Class 2
0.1 C (-50 to
+199.9 C)
1.0 C (remaining
range)
t99 (in
water)
10 s
0602 0293
Part no.
0554 0189
Radio handle for plug-in probe heads, incl. T/C adapter, approval for USA, CA, CL; Radio freq. 915.00 MHz FSK
0554 0191
0602 0394
40 mm
5 mm
12 mm
0602 0394
Measuring
range
Accuracy
Resolution
t99
-50 to +350 C
Short-term to
+500 C
Radio handle:
(0.5 C +0.3% of m.v.) (-40 to +500 C)
(0.7 C +0.5% of m.v.) (remaining range)
T/C probe head: Class 2
0.1 C (-50 to
+199.9 C)
1.0 C (remaining
range)
5s
Part no.
Radio handle for plug-in probe heads, incl. T/C adapter, approval for the countries: DE, FR, UK, BE, NL, ES, IT, SE, AT,
DK, FI, HU, CZ, PL, GR, CH, PT, SI, MT, CY, SK, LU, EE, LT, IE, LV, NO; Radio freq. 869.85 MHz FSK
Humidity probe head
0554 0189
Radio handle for plug-in probe heads, incl. T/C adapter, approval for USA, CA, CL; Radio freq. 915.00 MHz FSK
0554 0191
0636 9736
Dimensions
Probe shaft/probe shaft tip
Measuring
range
Accuracy
Resolution
0 to +100 %RH
-20 to +70 C
0.1 %RH
0.1 C
0636 9736
Part no.
Radio handle for plug-in probe heads, incl. T/C adapter, approval for the countries: DE, FR, UK, BE, NL, ES, IT, SE, AT,
DK, FI, HU, CZ, PL, GR, CH, PT, SI, MT, CY, SK, LU, EE, LT, IE, LV, NO ; Radio freq. 869.85 MHz FSK
0554 0189
Radio handle for plug-in probe heads, incl. T/C adapter, approval for USA, CA, CL; Radio freq. 915.00 MHz FSK
0554 0191
Illustration
Measuring
range
Accuracy
Resolution
-50 to +1000 C
testo-435-P08
06.08.2013
14:36
Seite 8
testo 435
We measure it.
Radio probes
Part no.
Radio module for measuring instrument, 869.85 MHz, approval for the countries: DE, FR, UK, BE, NL, ES, IT, SE, AT,
DK, FI, HU, CZ, PL, GR, CH, PT, SI, MT, CY, SK, LU, EE, LT, IE, LV, NO
0554 0188
Radio module for measuring instrument, 915.00 MHz FSK, approval for USA, CA, CL
0554 0190
Battery type
Measuring rate
Battery life
Radio coverage
Up to 20 m (without obstructions)
Radio transmission
Unidirectional
-20 to +50 C
Battery type
Operating temperature
Battery life
Storage temperature
-40 to +70 C
Protection class
IP54
Radio handle
0981 9614/msp/A/01.2014
www.testo.com