KKT Kraus
KKT Kraus
KKT Kraus
MAGNETOM AVANTO
MAGNETOM ESPREE
MAGNETOM Trio, A Tim System
R 134a
KCC 215-L-U/S
KCC 215-L-S
(US market)
(r.o.w. market)
H:\PM\Geraete\Avanto\Prospekt\Avanto0107.pmd
page 1
page 2
list of contents
page 5
page 6
page 7
page 8
page 9
page 10
page 11
page 12
page 13
page 14
page 15
page 16
waterchiller installation / I
page 17
waterchiller installation / II
page 18
page 19
page 20
overvolting protection
page 21
overview of waterchiller
transfer station / remote control panel
page 22
transport
H:\PM\Geraete\Avanto\Prospekt\Avanto0107.pmd
page 3
page 4
H:\PM\Geraete\Avanto\Prospekt\Avanto0107.pmd
page 5
page 6
technical data
Waterchiller
Typ KCC 215-L-U/S outdoor use
designed for MAGNETOM AVANTO / ESPREE / Trio, A Tim System
standard device
standard
construction
note
205,000
R 134a
2
18.2
[60.0]
10.0
4
1.54
+118
-4.0
[36,000]
cooling medium
PCW/AFN
min. cooling medium out (F [C])
+66.2
max. cooling medium out (F [C])
+71.6
temperature stabilty (K)
0.8
min. volume of cooling medium (gpm [l/min])
34.34
ext. pump pressure (psig [bar])
58.0
pump power (HP [kW])
4.0
PKW/AFN
[+19.0]
[+22.0]
[13.4]
[1.15]
+48
[-20]
[130.0]
[4.0]
[3.0]
61
55
50
480/3/60
24
58.5
IP 54
4.49
2
tolerance -14/+10%V/1 Hz
[17.0]
3,527 [1,600]
2,425 [1,100]
37.
8
96 0 inc
0m h
m
72.05 inch
1,830 mm
R 134a
h
nc
7i m
4
.
120 60 m
3,0
H:\PM\Geraete\Avanto\Prospekt\Avanto0107.pmd
Warning:
The 38% glycol rate depends
not on the local ambient
temperature !!!
page 7
page 8
technical data
Waterchiller
Typ KCC 215-L-S outdoor use
designed for MAGNETOM AVANTO / ESPREE / Trio, A Tim System
standard device
standard
construction
note
205,000
R 134a
2
21.7
[60.0]
10.0
4
1.54
+118
-4.0
[36,000]
cooling medium
PCW/AFN
min. cooling medium out (F [C])
+66.2
max. cooling medium out (F [C])
+71.6
temperature stabilty (K)
0.8
min. volume of cooling medium (gpm [l/min])
34.34
ext. pump pressure (psig [bar])
58.0
pump power (HP [kW])
4.0
PKW/AFN
[+19.0]
[+22.0]
[16.0]
[1.15]
+48
[-20]
[130.0]
[4.0]
[3.0]
61
55
50
380-480/3/50
24
55.0
IP 54
4.49
2
tolerance -14/+10%V/1 Hz
[17.0]
3,638 [1,650]
2,535 [1,150]
37.
8
96 0 inc
0m h
m
72.05 inch
1,830 mm
R 134a
h
nc
7i m
4
.
120 60 m
3,0
H:\PM\Geraete\Avanto\Prospekt\Avanto0107.pmd
Warning:
The 38% glycol rate depends
not on the local ambient
temperature !!!
page 9
air out
air out
3.54
37.80
5.90
120.47
2.00
air out
detail x
air in
air in
air in
air in
24.02
41.14
72.05
64.17
~3.15
8.07
1.57
carriage hole
4.53
4.53
KCC 215-L...
20.28
15.94
118.11
1.57
35.43
119.69
37.00
air in
detail x
air in
37.80
20
.8
air in
1.06
1.
120.47
0.67
0.79
switchboard
air out
air in
air in
35.04
72.05
11.22 11.81
air out
0.59
1.38
waterchiller
service side
0.59
10
air in
dimensions in inch.
0.79
6.10
1.57
59.05
59.05
118.11
119.68
page 10
5 = controll lamps
6 = switchboard ventilation
3 = DDC-display
4 = main switch
air out
air out
90
50
3060
960
150
air out
detail x
air in
air in
air in
air in
1630
610
1045
1830
ca.80
205
40
carriage hole
115
KCC 215-L...
115
515
405
3000
40
900
3040
940
air in
detail x
air in
960
53
0
air in
27
20
switchboard
air out
air in
air in
890
1830
285
300
air out
17
15
35
service side
3060
15
28
waterchiller
air in
dimensions in mm.
20
155
40
1500
1500
3000
3040
5 = controll lamps
6 = switchboard ventilation
3 = DDC-display
4 = main switch
H:\PM\Geraete\Avanto\Prospekt\Avanto0107.pmd
page 11
evaporator
expansion receiver
ACS
IFP
cooler (Siemens)
FS
flow meter
PI
pressure gauge
TT
temperature sensor
transfer station
H
shut-off valve
H
manual air vent
TA regulating valve
filter strainer
overflow valve
page 12
IFP
ACS Siemens
evaporator
1
2"
PI
evaporator
2
TT
Cu-pipe
with insulation
hose
1/2"
PI
2"
H
TA
TT
H:\PM\Geraete\Avanto\Prospekt\Avanto0107.pmd
FS
KKT
waterchiller
page 13
compressor with
crank-tub-heater
Rotalock valve
R134a
el.
solenoid valve
TC
thermostatic
expansion valve
evaporator
speed controller
PTH
PTL
vibration absorber
PZAHH
moisture indicator
Schrader valve
page 14
refrigerant diagram
evaporator
1
TC
TC
PTH
evaporator
2
TC
condensor 1
condensor 2
TC
PTH
system 1
PZAHH
PTH
el.
PTL
system 2
PZAHH
PTH
el.
PTL
H:\PM\Geraete\Avanto\Prospekt\Avanto0107.pmd
page 15
waterchiller installation / I
page 16
min.1000mm
waterchiller installation / II
installation example A
min.
40 inch
installation example B
installation example C
H:\PM\Geraete\Avanto\Prospekt\Avanto0107.pmd
page 17
IFP - manufacturer
connector fittings
located inside KKT-Chiller
page 18
IFP - manufacturer
H:\PM\Geraete\Avanto\Prospekt\Avanto0107.pmd
page 19
overvoltage protection
data transfer cable
(164 ft / 50m)
overvoltage protector
X8 Chiller cabinet
connection
grounding wire
Filter in
Filter out
grounding wire
mains box
grounding bus
page 20
overview of waterchiller
transfer station / remote control panel
3
data transfer cable
outdoor
KCC 215-L...
4
recommended
pipe dimensions
2"/50mm
< 45m/148ft
2 1/2"/65mm
> 45m/148ft
consult KKT
2"
2"
ASC Siemens
XGE 42-LR 1 1/2"
IFP
2
X810
IFP
technic room
data transfer cable
indoor
< 25m/82ft
interface station
ground
data transfer cable
overvoltage
protector
mains box
X81
X80
ACC
H:\PM\Geraete\Avanto\Prospekt\Avanto0107.pmd
page 21
mi
mi n . 1
n.
5
4, 8 i n c
00
0m h
m
transport
spacers
min. 158inch
min. 4,000mm
ch
in
4
m
2
0. 0m
11 ,80
2
s*
lb
8 kg
63
3 , 65 0
~ 1,
~
* = shipping weight
lifting tube
diameter max: 1.23inch/33mm
diameter min: 1.18inch/30mm
material thrickness: min. 0.12inch/3mm
length: 47.24inch/1,200mm
STRAP OR ROPE*
LOCKING PIN
SPILT PINS
LIFTING
TUBE
page 22
H:\PM\Geraete\Avanto\Prospekt\Avanto0107.pmd
page 23
Technical development
may cause changes of configuration
KKT-KRAUS
Refrigeration & Air Conditioning
Industriestrae 23a
D 91207 Lauf a. d. Pegnitz
Mail [email protected]
Phone +49 9123 174 01
page 24+49 9123 82441
Fax