UT803 Eng Manual
UT803 Eng Manual
UT803 Eng Manual
OPERATING MANUAL
TABLE OF CONTENTS
TITLE
Overview
Unpacking Inspection
Safety Information
Rules For Safe Operation
International Electrical Symbols
The Meter Structure
Rotary Switch
Functional Buttons
Display Symbols
Measurement Operation
A. DC or AC Voltage Measurement
B. DC or AC Current Measurement
C. Measuring Resistance
D. Testing for Continuity
E. Testing Diodes
F. Capacitance Measurement
G. Frequency Measurement
H. Temperature Measurement
I . Measuring Transistor
Operation of Hold Mode
The POWER Button
The SELECT Button
Turning on the Display Backlight
The RANGE Button
The MAX MIN Button
AC/AC+DC Button
PAGE
3
4
5
6
8
9
10
11
12
16
16
18
20
22
24
26
28
30
32
33
33
33
34
34
35
35
TITLE
POWER INPUT Switch
Sleep Mode
RS232 Button
General Specifications
Accuracy Specifications
A. DC Voltage
B. AC Voltage
C. DC Current
D. AC Current
E. Resistance
F. Continuity Test
G. Diode Test
H. Capacitance
I . Frequency
J. Temperature
K. Transistor
Maintenance
A. General Service
B. Replacing the Fuses
C. Replacing the Battery
RS232C and USB Serial Port
System Requirements for Installing the UT803 Interface Program
RS232C Serial Port
A. Connecting between the Meter and computer
B. RS232C Port Cable
C. Setting of RS232C Serial Ports
USB Serial Port
A. Connecting between the Meter and computer
B. Setting of USB Serial Ports
PAGE
35
36
36
37
38
38
39
41
42
43
44
44
45
46
47
47
48
48
49
51
52
52
53
53
54
54
55
55
55
Overview
This Operating Manual covers information on safety
and cautions. Please read the relevant information
carefully and observe all the Warnings and Notes strictly.
Warning
To avoid electric shock or personal injury, read the
Safety Information and Rules for Safety Operation
carefully before using the Meter.
Unpacking Inspection
Open the package case and take out the Meter. Check the following items carefully to see any missing or damaged
part:
Item
Description
Operating Manual
1 piece
Test Lead
1 pair
Alligator Clip
1 pair
Multi-Purpose Socket
1 piece
Point Contact Temperature Probe (to be used under 2300C temperature measurement)
1 piece
1 piece
1 piece
1 piece
1 piece
In the event you find any missing or damage, please contact your dealer immediately.
Qty
Safety Information
This Meter complies with the standards IEC61010: in
pollution degree 2, overvoltage category (CAT. I 1000V,
CAT.II 600V) and double insulation.
(Figure 1)
1. LCD Display
3. Input Terminals
2. Rotary Switch
4. Functional Buttons
Rotary Switch
Below table indicated for information about the rotary switch positions:
Rotary Switch Position
Function
AC and DC voltage measurement
:Continuity test.
:Diode test.
:Resistance measurement.
Capacitance test
Hz
0
hFE
A
mA
A
10
Hz :Frequency measurement.
0
F :Temperature in Fahrenheit
Temperature in celsius
Transistor test
AC or DC current measurement range from 0.1uA to 5999uA.
AC or DC current measurement range from 0.01mA to 599.9mA.
AC or DC current measurement range from 0.01A to 10.00A.
Functional Buttons
Below table indicated for information about the functional button operations.
Button
POWER
LIGHT
SELECT
Operation Performed
Turn the power on and off.
Turn the display backlight on and off.
l Switches between AC and DC measurement.
l Switches between continuity and diode and resistance measurements
l Switches between frequency and Fahrenheit temperature.
HOLD
Press HOLD to enter and exit the Hold mode in any mode, the Meter beeps.
RANGE
RS232C
Turn on or off the serial port interface without changing the original setting.
MAX MIN
Starts recording of maximum and minimum values. Steps the display through high (MAX) and low (MIN).
11
12
5.6.7
10 1
11
C umVA
~mV Trms
DC munF 0F
Mk Hz
0
14
HOLD
MAX
hFE
MIN
2
8
16
13
3 4
(Figure 2)
12
15
Number
Symbol
True RMS
HOLD
Meaning
AC
DC
AC+DC
OL
,K ,M
A, mA, A
13
Number
Symbol
V, mV
Meaning
F, mF,
F,nF
C, F
Centigrade temperature
Temperature in Fahrenheit
Hz, kHz,
MHz
14
Unit of transistor.
10
Test of diode
11
Number
Symbol
12
AutoRange
Meaning
Manual
13
MAX MIN
14
RS232
15
16
hFE
Transistor test is on
15
Measurement Operation
A. DC or AC Voltage Measurement (See figure 3)
Warning
To avoid harms to you or damages to the Meter from
electric shock, please do not attempt to measure
voltages higher than 1000V although readings may
be obtained.
16
(Figure 3)
17
18
(Figure 4)
Note
l If the value of current to be measured is unknown,
use the maximum measurement position, and reduce
the range step by step until a satisfactory reading is
obtained.
l For safety sake, each measurement time of high
current (>5A) should be less than 10 seconds and
the interval time between 2 measurements should
be greater than 15 minutes.
l When current measurement has been completed,
disconnect the connection between the testing leads
and the circuit under test, and remove the testing
leads away from the input terminals of the Meter.
19
(Figure 5)
20
Note
l The test leads and the Meter inside wire will bring
around 0.2
to 0.5 of error to resistance
measurement when measuring low resistance. To
obtain accurate readings in low-resistance, shortcircuit the test lead beforehand and record the reading
obtained, call this reading as X. Then use the equation:
measured resistance value (Y) (X) = accurate
readings of resistance.
l If
reading with shorted test leads is not < 0.5 ,
check for loose test leads, incorrect function selection,
or any other reasons.
l When measuring high resistance (>1M ), it is normal
to take several seconds to obtain a stable reading.
In order to obtain stable reading, choose shorter test
lead to carrying out measurement.
l The LCD displays OL indicating open-circuit for the
tested resistor or the resistor value is higher than the
maximum range of the Meter.
21
22
(Figure 6)
Note
l Open circuit voltage around -1.2V and range is 600 .
l When continuity testing has been completed,
disconnect the connection between the testing leads
and the circuit under test, and remove the testing
leads away from the input terminals of the Meter.
23
(Figure 7)
24
Note
l Connect the test leads to the proper terminals as
said above to avoid error display. The LCD will
display OL indicating diode being tested is open or
polarity is reversed. The unit of diode is Volt (V),
displaying the forward voltage drop readings.
l Open circuit voltage is around 2.7V.
25
(Figure 8)
26
Note
l The Meter displays a fixed value which is the
distributed capacitors value of the inside Meter. To
ensure accuracy, it is necessary to subtract this value
from the measured value when measuring small
capacitor.
l Multi-purpose socket can be used instead of testing
leads. Insert the capacitor being tested into the
corresponding input terminal of the multi-purpose
socket. When measuring small capacitor value,
more accurate value can be obtained using multipurpose socket.
l It is normal to take a longer time when testing a
capacitor value higher than 600F.
l The LCD displays OL indicating the tested capacitor
is shorted or it exceeds the maximum range.
27
(Figure 9)
28
Note
l When making frequency measurement, it must comply
with the following scope (a) requirement:
When 10Hz ~ 1Mz
:150mV a 30V rms
When > 1Mz~ 10MHz
:300mV a 30V rms
When > 10Mz~ 50MHz
:600mV a 30V rms
When > 50Mz
:Unspecified
l When frequency measurement has been completed,
disconnect the connection between the testing leads
and the circuit under test, and remove the testing
leads away from the input terminals of the Meter.
29
30
Note
l The testing environment must between 180C to 280C
to ensure accuracy especially when measuring low
temperature.
l Different reading may be obtained when testing room
environment under short or open circuit situation,
then short-circuited reading shall be considered as
the correct reading.
l The included point contact temperature probe can
only be used under 2300C. For any measurement
higher than that, the rod type temperature probe
must be used instead.
31
32
PNP
NPN
(Figure 11)
33
34
AC/AC+DC Button
It is used to select measuring AC or AC+DC when
measuring AC. Press it only at the AC voltage or current
measuring mode which is at the rotary switch
position V , mV ,A , mA or A . +DC will
be displayed when it is pressed under DC measurement
mode.
35
Sleep Mode
RS232 Button
36
General Specifications
l Maximum Voltage between any Terminals and
Grounding:
Refer to different range input protection voltage.
Fused Protection for HzmV Input Terminal:
l
200mA, 250V, fast type, 5x20mm (only apply on
hFE functions)
Fused Protection for AmA Input Terminal:
l
500mA, 250V, fast type, 5x20mm.
l
Fused Protection for 10A Input Terminal:
10A, 250V, fast type, 5x20mm.
l
Fused Protection for AC220V Terminal:
200mA, 250V, fast type, 5x20mm.
At AC220V power: without fuse protection.
l Maximum Display : Digital: 5999
l Measurement Speed: Updates 2-3 times/second.
: Manual or auto ranging.
l Range
: Auto
l Polarity Display
l Overloading Display : OL
l Temperature:
Operating: 00C to +400C (320F to +1040F).
Storage : -100C to +500C (140F to +1220F).
l Relative Humidity:
75% @ 00C - 300C below; 50% @ 30 - 400C.
l Altitude:
Operating: 2000 m.
Storage : 10000 m.
l Below 1V/m electrostatic discharge:
Accuracy = specified accuracy + 5% of the range.
Over 1V/m electrostatic discharge:Without
specified accuracy.
l Power:
AC220V/50Hz or 6 pieces of 1.5V battery (R14).
l Battery Deficiency:
Display
l Dimensions (HxWxL):
105 x 240 x 310 mm.
l Weight:
Approximate 2kg (accessories excluded).
l Safety/Compliances:
IEC61010 CAT. I 1000V, CAT. II 600V overvoltage
and double insulation standard.
l Certifications:
, UL pending.
37
Accuracy Specifications
Accuracy: (a% reading + b digits),guarantee for 1 year.
Operating temperature: 230C 50C.
Relative humidity: not more than 75% RH.
Temperature coefficient: 0.1 x (specified accuracy)/10C.
A. DC Voltage
Range
Resolution
600mV
0.1mV
6V
0.001V
60V
0.01V
600V
0.1V
1000V
1V
Remarks:
l Input Impedance:
At 600mV range : Around > 3000M .
At all other ranges: Around 10M .
38
Accuracy
Overload Protection
(0.6%+2)
(0.3%+2)
(0.5%+3)
1000V
B. AC Voltage
Range
Resolution
Accuracy
Overload Protection
40Hz-50kHz: (0.6%+5)
600mV
0.1mV
>50kHZ-100kHz: (1%+5)
40Hz-1kHz: (0.6%+5)
6V
0.001V
>1kHz-10kHz: (1.0%+5)
>10kHz-100kHz: (3%+5)
40Hz-1kHz: (0.6%+5)
60V
0.01V
1000V
>1kHz-10kHz: (1.5%+5)
>10kHz-20kHz: (3%+5)
>20kHz-100kHz: (8%+5)
600V
0.1V
1000V
1V
40Hz-1kHz: (0.6%+5)
>1kHz-10kHz: (3.5%+5)
40Hz-1kHz: (1.2%+3)
>1kHz-3kHz: (3%+3)
39
Remarks:
l Input Impedance:
At 600mV range : Around > 3000M
At all other ranges: Around 10M
l Displays:
True RMS (applicable to the range of 10%~95%)
At 1000V range: AC peak factor 1.5.
All other ranges: AC peak factor 3.0.
Input short circuit has around less than 30 remaining digits, it will not affect accuracy.
AC+DC measurement accuracy = range's accuracy + 1%
40
C. DC Current
Range
Resolution
Accuracy
Overload Protection
(0.5%+3)
600A
0.1A
6000A
1A
60mA
0.01mA
600mA
0.1mA
(0.8%+3)
10A
10mA
(1.2%+3)
Remarks:
l At 5A range: Continuous measurement is allowed.
l At >5A range: For continuous measurement 10 seconds and interval not less than 15 minutes.
41
D. AC Current
Range
Resolution
600A
0.1A
6000A
1A
60mA
0.01mA
600mA
0.1mA
10A
10mA
Accuracy
40Hz~10kHz: (1.0%+5)
>10kHz~15kHz: (2%+5)
Overload Protection
40Hz~10kHz: (1%+5)
>10kHz~15kHz: (3%+5)
40Hz~5kHz: (2.0%+6)
Fuse 10A,250V,
fast type, 5x20mm.
Remarks:
l At 5A range: Continuous measurement is allowed.
l At >5A range : For continuous measurement 10 seconds and interval not less than 15 minutes.
l Displays:
True RMS (applicable to the range of 10%~95%)
AC peak factor 3.0.
Input short circuit has around less than 30 remaining digits, it will not affect accuracy.
AC+DC measurement accuracy = range's accuracy + 1%
42
E. Resistance
Range
Resolution
Accuracy
Overload Protection
0.1
6k
0.001k
60k
0.01k
600k
0.1k
6M
0.001M
(0.8%+2)
60M
0.01M
(1.2%+3)
250V rms
43
F. Continuity Test
Range
Resolution
Overload Protection
Remarks
l Open circuit voltage approximate -1.2V.
l When circuit disconnected with resistance value
250V rms
70
G. Diode Testst
Range
Resolution
10mV
Overload Protection
250V rms
Remarks
l Open circuit voltage approximate 2.7V.
l Working current approximate 1mA.
44
H. Capacitance
Range
Resolution
6nF
0.001nF
60nF
0.01nF
600nF
0.1nF
6F
0.001F
60F
0.01F
600F
0.1F
(3%+4)
6mF
0.001mF
(5%+4)
Remarks:
l At 6nF, 60nF and 600nF Range: reading must subtract
Accuracy
Overload Protection
(2.5%+5)
(2%+5)
250V rms
45
I. Frequency
Range
Resolution
6kHz
0.001kHz
60kHz
0.01kHz
600kHz
0.1kHz
6MHz
0.001MHz
60MHz
0.01MHz
Remarks:
l Input scope (a): (DC electric level is zero)
When 10Hz ~ 1MHz
: 150mV a 30V rms
When > 1MHz ~ 10MHz : 300mV a 30V rms
When > 10MHz ~ 50MHz : 600mV a 30V rms
When > 50MHz
: Unspecified
46
Accuracy
Overload Protection
(0.1%+3)
250V rms
J. Temperature
Range
Resolution
Accuracy
0
-40 C~0 C
0
1C
(8%+5)
>0 C~400 C
0
(1%+3)
0
>400 C~1000 C
0
-40 C~32 C
0
1F
250V rms
(1.5%+3)
(8%+5)
>32 F~752 F
0
Overload Protection
(1.5%+5)
0
>752 F~1832 F
(2.5%+5)
Remarks:
l The included point contact temperature probe can only be used to measure under 2300C temperature. For any
measurement higher than that, the rod type temperature probe must be used instead.
K. Transistor
Range
hFE
Resolution
1
Overload Protection
l Fuse 200mA, 250V, fast type, 5x20mm.
l Fuse 500mA, 250V, fast type, 5x20mm
Remarks
Vce
2.2V bo
10A
1000 MAX
47
Maintenance
A. General Service
Warning
Do not attempt to repair or service your Meter unless
you are qualified to do so and have the relevant
calibration, performance test, and service information.
To avoid electrical shock or damage to the Meter, do
you get water inside the case.
48
(Figure 12)
49
50
(Figure 13)
51
52
(Figure 14)
53
54
D-sub
D-sub
9 Pin Female 25 Pin Female
1 (DCD)
8 (DCD)
3 (TXD)
2 (TXD)
2 (RXD)
3 (RXD)
4 (DTR)
20 (DTR)
5 (SG)
7 (SG)
6 (DSR)
6 (DSR)
7 (RTS)
4 (RTS)
8 (CTS)
5 (CTS)
9 (RI)
22 (RI)
(Figure 15)
55
56