Rr410203-Computer Methods in Power Systems Final
Rr410203-Computer Methods in Power Systems Final
No: 27019
RR SET-1
2a) Describe the Newton – Raphson method for the solution of power flow equations in
power systems deriving necessary equations.
b) What are P – V Buses? How are they handled in the above method? [12 + 4]
3a) Derive Fash – Decoupled load flow algorithm and give step by step procedure for
implementing this algorithm.
b) State merits and demerits of this method. [8 + 8]
4a) Derive the expression for bus voltage, line currents when a three phase symmetrical
fault through fault impedance occurs at a particular bus using bus Impedance matrix.
b) A three phase fault with a fault impedance of 0.16 P.V occurs at bus 3, for which
Z BUS is given by
1 2 3
1 ⎡ j 0.016 j 0.8 j 0.12 ⎤
Z BUS = 2 ⎢⎢ j 0.08 j 0.24 j 0.16 ⎥⎥
3 ⎢⎣ j 0.12 j 0.16 j 0.34 ⎥⎦
Compute the fault current, the bus voltage, and the line currents during the fault.
Assume prefault bus voltages 1.0 per unit. [8 + 8]
5. Develop the expressions for the following matrices which are used for shunt fault
analysis for a line to line fault occurring on conventions phases
a) Fault admittance matrix in phase and sequence component form
b) Derive the formulae used. [8 + 8]
7a) Discuss the methods to improve steady state and transient state stability limits.
b) What is equal area criteria? Explain how it can be used to study stability? Select any
suitable example. [8 + 8]
*****
Code.No: 27019
RR SET-2
1a) Derive Fash – Decoupled load flow algorithm and give step by step procedure for
implementing this algorithm.
b) State merits and demerits of this method. [8 + 8]
2a) Derive the expression for bus voltage, line currents when a three phase symmetrical
fault through fault impedance occurs at a particular bus using bus Impedance matrix.
b) A three phase fault with a fault impedance of 0.16 P.V occurs at bus 3, for which
Z BUS is given by
1 2 3
1 ⎡ j 0.016 j 0.8 j 0.12 ⎤
Z BUS = 2 ⎢⎢ j 0.08 j 0.24 j 0.16 ⎥⎥
3 ⎢⎣ j 0.12 j 0.16 j 0.34 ⎥⎦
Compute the fault current, the bus voltage, and the line currents during the fault.
Assume prefault bus voltages 1.0 per unit. [8 + 8]
3. Develop the expressions for the following matrices which are used for shunt fault
analysis for a line to line fault occurring on conventions phases
a) Fault admittance matrix in phase and sequence component form
b) Derive the formulae used. [8 + 8]
5a) Discuss the methods to improve steady state and transient state stability limits.
b) What is equal area criteria? Explain how it can be used to study stability? Select any
suitable example. [8 + 8]
8a) Describe the Newton – Raphson method for the solution of power flow equations in
power systems deriving necessary equations.
b) What are P – V Buses? How are they handled in the above method. [12 + 4]
*****
Code.No: 27019
RR SET-3
1. Develop the expressions for the following matrices which are used for shunt fault
analysis for a line to line fault occurring on conventions phases
a) Fault admittance matrix in phase and sequence component form
b) Derive the formulae used.. [8 + 8]
3a) Discuss the methods to improve steady state and transient state stability limits.
b) What is equal area criteria? Explain how it can be used to study stability? Select any
suitable example. [8 + 8]
7a) Derive Fash – Decoupled load flow algorithm and give step by step procedure for
implementing this algorithm.
b) State merits and demerits of this method. [8 + 8]
8a) Derive the expression for bus voltage, line currents when a three phase symmetrical
fault through fault impedance occurs at a particular bus using bus Impedance matrix.
b) A three phase fault with a fault impedance of 0.16 P.V occurs at bus 3, for which
Z BUS is given by
1 2 3
1 ⎡ j 0.016 j 0.8 j 0.12 ⎤
Z BUS = 2 ⎢⎢ j 0.08 j 0.24 j 0.16 ⎥⎥
3 ⎢⎣ j 0.12 j 0.16 j 0.34 ⎥⎦
Compute the fault current, the bus voltage, and the line currents during the fault.
Assume prefault bus voltages 1.0 per unit. [8 + 8]
*****
Code.No: 27019
RR SET-4
1a) Discuss the methods to improve steady state and transient state stability limits.
b) What is equal area criteria? Explain how it can be used to study stability? Select any
suitable example. [8 + 8]
4a) Describe the Newton – Raphson method for the solution of power flow equations in
power systems deriving necessary equations.
b) What are P – V Buses? How are they handled in the above method. [12 + 4]
5a) Derive Fash – Decoupled load flow algorithm and give step by step procedure for
implementing this algorithm.
b) State merits and demerits of this method. [8 + 8]
6a) Derive the expression for bus voltage, line currents when a three phase symmetrical
fault through fault impedance occurs at a particular bus using bus Impedance matrix.
b) A three phase fault with a fault impedance of 0.16 P.V occurs at bus 3, for which
Z BUS is given by
1 2 3
1 ⎡ j 0.016 j 0.8 j 0.12 ⎤
Z BUS = 2 ⎢⎢ j 0.08 j 0.24 j 0.16 ⎥⎥
3 ⎢⎣ j 0.12 j 0.16 j 0.34 ⎥⎦
Compute the fault current, the bus voltage, and the line currents during the fault.
Assume prefault bus voltages 1.0 per unit. [8 + 8]
7. Develop the expressions for the following matrices which are used for shunt fault
analysis for a line to line fault occurring on conventions phases
a) Fault admittance matrix in phase and sequence component form
b) Derive the formulae used. [8 + 8]
*****