SPECIFICATIONS:
9
1
8
5
WATER:
FLOW RATE: 3000-15000USGPM
OPER. PRESSURE RANGE: 50-175 PSIG
PRESSURE LOSS @ 8000 USGPM: 16 PSIG
OPTIMUM OPER. PRESSURE: 155PSIG (INLET)
ELECTRICAL:
BY
GL
10
2
MOUNTING:
INLET: INLET FLANGE TO CUSTOMER SPECIFICATION
OUTLET: 8.00" 150# RF ANSI FLANGE
MATERIALS:
WATERWAY: 304 STAINLESS STEEL
(COATED INSIDE AND OUT)
SWIVELS: ALUMINUM NICKEL BRONZE
MOTOR HOUSINGS: 304 STAINLESS STEEL
UNIT WEIGHT: 698 LBS (DRY)
12
10
102478-325C
20
101715-75C
20
103109-4C
102478-350C
980200
104460-8
260857-38
20
100249-13C
260843-1
125010-5
QTY.
ITEM NO.
PART NUMBER
DESCRIPTION
UNLESS OTHERWISE
SPECIFIED: DIMENSIONS
WWW.STANGINDUSTRIES.COM
ARE IN INCHES
951-479-9810
TOLERANCES
DECIMALS ANGULAR
.XX .03
2
MONITOR, 8.00'' ELECTRIC SLP, FLANGE TO FLANGE, SS-AB,
.XXX .010
WITH FLOW STRAIGHTENER AND SHAPER TIP
TREATMENT
N/A
FINISH
N/A
N/A
NOTE
PART#
980200-1-SD
DRAWN
CAGE
DATE
04-14-08
DESIGN
GL
REF PART #
CHECK
SCALE
REVISION
NTS
SHEET
A
1 OF 1
REVISIONS
NOTES:
1.
DO NOT SCALE THIS DRAWING.
2.
BREAK ALL SHARP EDGES.
3.
ALL DIMENSIONS DISPLAYED IN PARENTHESES
ARE FOR REFERENCE ONLY.
REV.
A
DESCRIPTION
INITIAL RELEASE
DATE
04-21-08
BY
GL
SPECIFICATIONS:
WATER:
14
13
9
4
11
15
12
17
15 MAX.
16
4
6
75 MAX.
10
18 19 20
21
22
22
800310-51
21
800310-41
20
800310-31
19
800310-21
18
800310-11
17
800310-1
16
16
16
16
16
16
16
102980-3C
16
16
16
16
16
16
15
103109-8C
14
101204-5C
13
104842-24C
12
162415-7
48
48
48
48
48
48
11
103109-4C
48
48
48
48
48
48
10
102478-225C
301583-1
100128-049
750618-1
801420-5
299380-1V
299380-1H
125010-5
801886-1
801897-11
PART NUMBER
UNLESS OTHERWISE
SPECIFIED: DIMENSIONS
ARE IN INCHES
TOLERANCES
DECIMALS ANGULAR
1
.XX .03
.XXX .010
DESCRIPTION
N/A
SUPPLIER
N/A
N/A
NEW PART
NUMBER
980200
CAGE#
DRAWN
DATE
DESIGN
04-21-08
GL
CHECK
REVISION
SCALE
SHEET
1:4
1 OF 2
NOTES:
1.
SEE SHEET #1.
5
4
17
14
13
12
8
11
16
10
7
15
16
16
16
16
16
16
17
102980-3C
16
101204-5C
15
162415-7
16
16
16
16
16
16
14
103109-8C
48
48
48
48
48
48
13
103109-4C
48
48
48
48
48
48
12
102478-225C
11
104842-24C
10
301583-1
100128-049
750618-1
801420-5
299380-1V
299380-1H
125010-5
801886-1
801897-11
800310-41
800310-31
800310-51
800310-21
800310-11
800310-1
-51/QTY.
-41/QTY.
-31/QTY.
-21/QTY.
-11/QTY.
PART NUMBER
DESCRIPTION
UNLESS OTHERWISE
SPECIFIED: DIMENSIONS
ARE IN INCHES
TOLERANCES
DECIMALS ANGULAR
1
.XX .03
.XXX .010
N/A
SUPPLIER
N/A
N/A
NEW PART
NUMBER
980200
CAGE#
DRAWN
DATE
DESIGN
04-21-08
GL
CHECK
REVISION
SCALE
SHEET
NONE
2 OF 2
REVISIONS
NOTES:
1.
DO NOT SCALE THIS DRAWING.
2.
BREAK ALL SHARP EDGES.
3.
ALL DIMENSIONS DISPLAYED IN PARENTHESIES
ARE FOR REFERENCE ONLY.
4
LTR
REVISION
DATE
BY
INITIAL RELEASE
04-15-08
GL
22
10
25
24
20
21
15
3
7
23
.13
GTAW
26
9
8.44
19
.10
11
82
27
100083
12
26
103109
25
102472
24
760660
23
101498
22
103109
21
102981
20
760660
19
250315
17
103831-151
12
801350-4
11
1.00SQ-STL
1.00SQX.75L-STL
10
104334-175C
12
102978-2
101365-2
100128-230
101365-6
100128-236
131300-3
710250-1
131200-3
255490-1
12
.13
GTAW
.510
1.020
.313
NOTCH
FLANGE ONLY
PART NUMBER
DESCRIPTION
N/A
SUPPLIER
N/A
N/A
NEW PART
NUMBER
299380-1-H
CAGE#
DRAWN
DATE
DESIGN
04-15-08
GL
CHECK
REVISION
SCALE
SHEET
1:2
1 OF 1
REVISIONS
NOTES:
1.
DO NOT SCALE THIS DRAWING.
2.
BREAK ALL SHARP EDGES.
3.
ALL DIMENSIONS DISPLAYED IN PARENTHESIES
ARE FOR REFERENCE ONLY.
LTR
REVISION
DATE
BY
INITIAL RELEASE
04-15-08
GL
9
27
27
12
13
4.625
1.000
22
5
26
GTAW
.100
.12
23
2
4
15
27
24
25
10
2
4
21
20
11
15
82
12
4
1
1
1
1
1
1
28
27
26
25
24
23
22
21
20
100083
103109
102472
760660
101498
103109
102981
760660
250315
18
103831-151
13
801415-11
12
1.00SQ-STL
1.00SQX2.00L-STL
11
1.00SQ-STL
1.00SQX1.50L-STL
10
12
102978-2
101365-2
100128-230
101365-6
100128-236
131300-3
710250-1
131200-3
255490-1
299380-1V/QTY.
ITEM NO.
75
1.020
PART NUMBER
UNLESS OTHERWISE
SPECIFIED: DIMENSIONS
ARE IN INCHES
TOLERANCES
DECIMALS ANGULAR
1
.XX .03
.XXX .010
.510
NOTCH FLANGE
ONLY
.313
DESCRIPTION
52
TREATMENT
FINISH
38
N/A
SUPPLIER
N/A
N/A
NEW PART
NUMBER
299380-1-V
CAGE#
DRAWN
DATE
DESIGN
04-15-08
GL
CHECK
REVISION
SCALE
SHEET
1:2
1 OF 1
TB-104
8.0 (200MM) SUPER LOW-PRO MONITOR (FLANGED)
INSTALLATION INSTRUCTIONS
MODEL # 980200
1) Refer to the appropriate drawing for vertical and horizontal operating radii of the
monitor. Make sure the monitor installation location is free from obstructions to
normal operation of the unit.
2) Make sure that mounting flange and piping is sturdy enough to withstand the
powerful jet reaction force produced by the monitor, i.e. overturning moment and
shear on the flange mounting bolts. Jet reaction forces at various flow rates and
pressures can be found on catalog page 10.3.1 in the back of this manual.
3) Install monitor using suitable fasteners that properly fit the flanges, Grade 5
minimum. Refer to the illustration below for correct orientation.
4) Install nozzle on outlet of monitor. If nozzle is flanged then use -10UNC
(orM20) Grade 5 stainless steel bolts or better if nozzle is threaded style, use
appropriate spanner wrench and tighten securely to monitor Foam Aspirating
nozzle is fitted with 5/8UNC or M16 bolts. Fog/Jet nozzle is fitted with UNC
Bolts. Stang to supply at commissioning.
5) Connect flexible hydraulic hoses for spray deflector and changeover mechanism if
relevant.
6) Make electrical connections using appropriate wire size for length of run and full
load current requirements. Current draw may be found on monitor top assembly
drawing (980200)
7) NOTE: Check that motors are wired to suit supplied voltage, motors are supplied
hi and lo voltage, instructions given on motor. If Phases to the motor are such that
the motors turn in the wrong direction then this may prevent the proximity switch
not to function.
8) Switch on the power switch on the control panel. Make sure that the green LED
is lit when power is activated if so equipped. If LED is not lit, then recheck
power connections.
9) Without water turned on to the unit, check for proper function of the monitor, i.e.
UP, DOWN, LEFT AND RIGHT movement.
10) Set vertical and horizontal sweep limit (proximity) switches to desired monitor
travel limits.
TB-105
8.0 (200MM) SUPER LOW-PRO MAINTENANCE PROCEDURE
& RECOMMENDED SPARE PARTS LIST
Maintenance:
1) Swivel assemblies should be greased periodically to ensure proper
lubrication during use. Use good quality lithium or molybdenum
grease. Always use a hand operated grease gun. DO NOT use a
pressurized grease gun as this may cause damage to the swivel races,
pressure seal or ball access plugs. Swivel assemblies should be
greased once a month during heavy usage and once every three
months during light usage.
2) Monitor should be checked for leaks and proper function once a
month. Check all fasteners for tightness. Check all electrical cables
and fittings.
3) Monitor is manufactured with corrosion resistant materials
throughout. Regular inspection of coatings is advised.
Qty: 1
Qty: 1
Qty: 1
Qty: 2
Qty: 1
Qty: 4
Technical Bulletin
_____________________________________________________________________________________________
Pd
Pn
(Q/K)2
Flow rate
Procedure: Calculate the system pressure drop for several different flow rates, convert to FT. by
multiplying by 2.31 and then add the static head. Plot the system pressure drop characteristics on the
pump curve. The system flow rate is where the two lines cross.
Technical Bulletin
_____________________________________________________________________________________________
Stang has received Bureau Veritas approval for marine monitors used in the North Sea. Stang monitors
are also in service on several abs (American Bureau of Shipping) certified vessels.
Stang used UL/FM/CSA electrical components on remotely controlled monitor systems when required
and/or available. All monitors are designed and manufactured in the United States meeting Stangs
stringent quality controls standards.
Stang has a reputation of excellence around the world in the monitor business with products in at least
85% of the refineries in the United States. In many refineries, Stang is the standard with no equal.
(Please see the attached Stang Quality Statement.)
This information and data has been supplied in order to help in the evaluation of Stangs monitors and
support equipment/systems.
Technical Bulletin
_____________________________________________________________________________________________
Technical Data
_____________________________________________________________________________________________
_____________________
Charles Ronie
President
Stang Industrial Products