Menu button, after downloading the screen data to HMI, press the
System Menu button to enter the system menu.
Method 2Please press at blank space for a while, and then will hear
Buzzer sound and display as below following windows for asking
users Enter the system menu.
If users select Ethernet to download, please enter the system menu to set
DHCP to OFF and set the IP address manually at first.
DOP-W Series provide two Ethernet LAN devices to download and upload
screen data or recipe, get firmware information and reset HMI. It also
could plan two Ethernet LAN devices in different domains for application.
As below will introduce functions for DOP-W Series.
1Password Setting
Password setting is used to divide user level with HMI. The security level
involved 0 to 7 and has default password in every security level. DOP-W
Series also provide multi-account and password to let several users log in to
HMI.
NOTE
Please do not set the same account in the same security level, but it could
set the same password in the same security level.
The account could set the same in different security level. For example, if
security level 0 set account to 123, the 123 account also could set in
security level1.
The length limitation for account and password is 24 characters.
The account and password are case insensitive. It will only display the
capital letters.
Security Level 0
Security Levels
1~7
Security Level 8
When the user wants to change the password in each level, this can be done
by changing the password entry through [Options] [Password Setting]. The
length limitation for account and password is 24 characters. The entered
password can have up to 8 digits, which consist of numbers of 0 ~ 9 and
alphabets of A ~ F regardless of capitalization or lower-case. The user can
choose the digits and characters of the password as preferred with flexibility.
When users set the same account in the same security level, HMI will display Account
Duplicate error message.
Users also could via Password table setup element to change account and
password.
Or enter system menu and select System setting Security to change account and
password.
2Multimedia
DOP-W Series provides multimedia player used to play operation and
maintenance instructions video, so that each operator can have a clear and
straightforward, and thus more effective to reach work; or standard operating
procedures used to play video presentation to help user who establish a good
working environment.
Video can be selected directly or video files you would like to play within the
Word register values to specify a different video files to play
Note
Video Lists Output Setting, Control address, and Play List are described in the
details below.
Video Lists Output Setting
Table 2-1Video
Add
Delete
Once the Add button is clicked, the software will ask the user
to select the video file to be played.
After the video file is exported, one can see that the software is
executing the export.
10
ID
11
Available Save Locations are USB and SD. The user can
change the Save Location as preferred with the default as SD.
The filename of the video file added to the list will be displayed
as Video, with the first video file starting at 001 and the
following files go by Video001, Video 002 and Video 003.
Source refers to the path and address of the video file after
being added. After adding the video file, the user can change
the source file, namely, replace other video files.
Save
Location
Video
Name
Source
12
Control Address
Table 2-2Control Address
Control address only can be set as Word format to control video play
and stop action.
It can be set as controller address and internal address.
Note
If control addres set as $200, but user could create maintained button
to set address as $200.0. The operate behavior is press $200.0
means video play, relase the $200.0 means video stop.
Control address
Controller address
(Link1@D100)
(EtherLink1@D200)
Internal address
Play
Stop
D100 = 1
D100 = 0
D200 = 1
D200 = 0
$200 = 1
$200 = 0
($200)
13
Play List
Table 2-3Play List
How the Play List is read depends on the video files added to be
played.
The read methods include File and Address.
14
Play List
Table 2-3Play List
When Add play item is selected, the software will ask the
user to select the video files to be added to Play List.
After add video item to play list, the default Mode is File.
Users could change the Mode to Address or keep the
original setting as File.
Add
Before
Remove
After
Mode
Play List
Table 2-3Play List
Name
Play List
Table 2-3Play List
Repeat
17
18
Example of Video
Table 2-4Example of Video
Video
19
Example of Video
Table 2-4Example of Video
Create
Maintained
Button
(Video
Play)
20
Example of Video
Table 2-4Example of Video
Compile
and
Download
screen
data to
HMI
Operating
HMI
EtherLink2_1}1@D10 = 2
{Link2}1@D20 = 6
{EtherLink2_1}1@D5 = 1
3VNC
VNCVirtual Network Computing is a PC software used to help the
customers view and check the same screen shown on W series of HMI at the
production site, and control the manufacturing process via Ethernet. No matter
where you are, remote controlling is not an arduous task at all.
3.1
Use Screen Cycle Macro and enter the following commands in macro
command window.
22
Click Options > Configuration > Network App > LocalHost, check the
Application (Net App VNC) function Enable. Then, press OK button to finish
the settings.
After finishing above setting, please compile and download all screen data
to HMI.
23
3.2
VNC Setting
There are three ways to use VNC Viewer to connect with HMI.
Computer Software
Web Browser
Android App
24
25
26
User could check create a VNC Viewer desktop icon option or not and
then click on Next.
27
Please check the Add an exception to the firewall for VNC Server,
and then click on Next.
28
29
31
The default connection port number for web browser is 5800. Please
do not set the connection number port to 5800 in VNC network setting
in DOPSoft. If user set to 5800, after download to HMI, it will appear
following as below message to inform user to change port number.
32
Step1. Open the web browser, for example is using Google Chrome.
Google Chrome browser connection example:
Please type the IP address and port number:
http://192.168.123.48:5800/.
IE browser connection example:
Please type the IP address and port number:
http://192.168.123.26:5800/.
Firefox browser connection example:
If use Firefox browser to connect, please turn off the proxy at first.
Then type the IP address and port number:
http://192.168.123.26:5800/.
If type incorrect IP address, it will not display any content.
33
Step2. Please input the password to connect with HMI, the default
password is 12345678 which set from DOPSoft VNC.
34
c. Android App
Please get the VNC Viewer App from Google play store at first.
After download, please execute the app to finish the following
steps.
Step1. Please click on the bottom left cornerto add new
connection.
35
36
37
38
Step4. It will ask user to input the password to connect with HMI, the
default password is 12345678 which set from DOPSoft VNC.
39
40
41
3.3
2. After new connection establishing, the VNC Viewer is connecting with two
HMIs.
42
Save
Connection
1. Click on
43
44
Only start VNC Address Book and select the connected IP address when
next connection.
Close
Connection
Click on
Options
Connection
Information
46
4e-Printer
ePrinter offer users in HMI without connecting entity end printers can print
directly through the Internet, space-saving and printing hardware devices
convenience. Please refer to as below structure of ePrinter.
e-Printer function could described as two parts. Fisrt is introduce for PrnServer;
Second is how to set HMI connect with ePrinter to print.
4.1 PrnServer
PrnServer is an execution file, users could start the PrnServer and deliver file
to print through Ethernet.
PrnServer execution file location as below path C:\Program Files (x86)\Delta
Industrial Automation\DOPSoft 2.00.01\PrnServer.exe.
47
Start
Printer
Stop
Setting
48
Exit
Help
About
to close, it will
Display current
49
version of
PrnServer.
50
Printer setting
Select Options ConfigurationsPrint and choose Ethernet at Interface, fill
IP address and printer port.
PortThe default printer port is 85. When open PrnServer connection, the
connected printer port is also 85 like as below figure.
51