Specifications Specifications Specifications: Analog Input Analog Input Analog Input

This document provides specifications for three analog input modules: the ADAM-4017+ 8-channel analog input module, the ADAM-4018+ 8-channel thermocouple input module, and the ADAM-4018M 8-channel analog input data logger. All three modules have 16-bit effective resolution, 3000VDC isolation voltage, and built-in protection from overvoltage and ESD. The main differences are that the ADAM-4017+ accepts various voltage and current types, the ADAM-4018+ accepts thermocouples and some voltage/current types, and the ADAM-4018M also accepts thermocouples but includes data logging functionality.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
77 views1 page

Specifications Specifications Specifications: Analog Input Analog Input Analog Input

This document provides specifications for three analog input modules: the ADAM-4017+ 8-channel analog input module, the ADAM-4018+ 8-channel thermocouple input module, and the ADAM-4018M 8-channel analog input data logger. All three modules have 16-bit effective resolution, 3000VDC isolation voltage, and built-in protection from overvoltage and ESD. The main differences are that the ADAM-4017+ accepts various voltage and current types, the ADAM-4018+ accepts thermocouples and some voltage/current types, and the ADAM-4018M also accepts thermocouples but includes data logging functionality.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

ADAM-4017+

ADAM-4018+
ADAM-4018M

8-channel Analog Input Module


with Modbus
8-channel Thermocouple Input
Module with Modbus
8-channel Analog Input Data
Logger

ADAM-4017/4017+

ADAM-4018/4018+

Specications

Specications

Specications

Analog Input

Analog Input

Effective Resolution
Channels

Effective Resolution
Channels

Analog Input
Effective Resolution
Channels

Channel Independent
Configuration
Modbus
lnput Type
lnput Range

16-bit
Six differential, two
single-ended (4017)
eight differential (4017+)
ADAM-4017+ only

ADAM-4017+ only
mV, V, mA
150 mV, 500 mV, 1
V, 5 V, 10 V, 20 mA,
4~20mA (4017+ only)
Isolation Voltage
3000 VDC
Fault and Overvoltage Withstands overvoltage
Protection
up to 35 V
Sampling Rate
10 samples/sec. (total)
Input Impedance
20 M
Bandwidth
13.1 Hz @ 50 Hz,
15.72 Hz @ 60 Hz
Accuracy
0.1% or better
Zero Drift
6 V/ C
Span Drift
25 ppm/ C
CMR @ 50/60 Hz
92 dB min.

Built-in Watchdog Timer


Power Requirements

Unregulated +10 ~
+30 VDC
Power Consumption
1.2 W @ 24 VDC
Built-in TVS/ESD Protection

Ordering Information
ADAM-4017-D2
ADAM-4017+

8-channel Analog Input


Module
8-channel Differential Analog
Input Module w/Modbus

ADAM-4018M

16-bit
Six differential, two
single-ended (4018)
eight differential (4018+)
Ch. Independent Conf. ADAM-4018+ only
Modbus
ADAM-4018+ only
lnput Type
Thermocouple, mV,
V, mA (4018) (4018+
Supports T/C & 4~20
mA only)
lnput Range
15 mV, 50 mV, 100
mV, 500 mV, 1 V, 2.5
V, 20 mA (4018);
4~20 mA (4018+)
T/C Type and Temperature Ranges

J 0 ~ 760 C
K 0 ~ 1370 C
T -100 ~ 400 C
E 0 ~ 1000 C
Isolation Voltage
Fault and Overvoltage
Protection
Sampling Rate
Input Impedance
Bandwidth

Accuracy
Zero Drift
Span Drift
CMR @ 50/60 Hz

R
S
B

500 ~1750 C
500 ~1750 C
500 ~1800 C

3000 VDC
Resists overvoltage up
to 35 V
10 samples/sec. (total)
20 M
13.1 Hz @ 50 Hz,
15.72 Hz @ 60 Hz
0.1% for voltage input
3 V/ C
25 ppm/ C
92 dB min.

Built-in Watchdog Timer and Individual wire


burned-out detection (4018+ only)
Power Requirements

Unregulated +10 ~
+30 VDC
Power Consumption
0.8 W @ 24 VDC
Built-in TVS/ESD Protection

Ordering Information
ADAM-4018-D2
ADAM-4018+

16-bit
Six differential, two
single-ended
lnput Type
Thermocouple, mV, V,
mA
lnput Range
15 mV, 50 mV, 100
mV, 500 mV, 1 V, 2.5
V, 20 mA
T/C Type and Temperature Range
J
K
T
E

R
S
B

0 ~ 760 C
0 ~ 1370 C
-100 ~ 400 C
0 ~ 1000 C

Isolation Voltage
Sampling Rate
Input Impedance
Bandwidth

Accuracy
Zero Drift
Span Drift
CMR @ 50/60 Hz

500 ~1750 C
500 ~1750 C
500 ~1800 C

3000 VDC
10 samples/sec. (total)
1.8 M
13.1 Hz @ 50 Hz,
15.72 Hz @ 60 Hz
0.1% for voltage input
3 V/ C
25 ppm/ C
92 dB min.

Storage

Capacity
38,000 samples (total)
(128 KB flash memory)
Storage Mode
Write to end of memory
& cyclic
Logging Mode
Internal log or event log
(high/low)
Sampling Interval
2 secs. ~ 18 hours

Built-in Watchdog Timer


Power Requirements
Power Consumption

Unregulated +10 ~
+30 VDC
1.8 W @ 24 VDC

Ordering Information
ADAM-4018M

8-ch. Th.couple Input Module


8-ch. Differential, mA and
Thermocouple Input Module
w/Modbus

8-channel Analog Input


Data logger mV, V, mA, or
thermocouple

Online Download www.advantech.com/products


All product specifications are subject to change without notice

Last updated : January 2005