OGi Bloc Dry-OGiV Sealed Lead-Acid Battery

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

Automotive Batteries for OEM

Automotive Batteries
Motive power
Railway battery systems

OGi bloc dry/OGiV

Power supply

S E A L E D L E A D - A C I D B AT T E R Y

Stand by

HOPPECKE
Batterien

OGi bloc dry/OGiV

SEALED LEAD-ACID BAT TERY


Applications
OGi bloc dry and OGiV batteries are used in a great variety of applications:
In UPS units
In telecommunications installations
In signalling and control systems
In safety systems

Product features
Performance
OGi bloc dry 12 V batteries cover a capacity range of 30 - 100 Ah in accordance with
DIN 40741. OGiV 6 V and 4 V batteries cover a capacity range of 18 - 256 Ah according to DIN 40741.
OGi bloc dry and OGiV batteries
are used in switching centres.

Electrodes
The electrodes of the OGi bloc dry and OGiV batteries consist of positive and negative
grid plates, based on a lead-calcium grid alloy.
Separators
Microporous glass mat separators are used to separate the electrodes. The fibre glass
mat forms an effective insulation between the electrodes and prevents the loss of
active material through shedding. Together with the electrodes the absorbent glass mat
binds the electrolyte and enables oxygen to diffuse easily from the positive to the
negative electrode.
Pole bushing
The pole bushings are gas-tight to avoid any electrolyte leakage for the batterys entire
service life.
Cell connectors
The cells are connected by fully insulated copper screw connectors.
Electrolyte
The electrolyte, which is fixed in glass mat separators, ensures the highest reliability
for all applications. The batteries are delivered in a filled and charged state and are
ready for immediate use.

Hoppecke OGi bloc dry and OGiV


batteries come in 4 V, 6 V and 12 V.

Containers
The battery containers are made of high-strength plastic (PP or ABS). Container and lid
are bonded together to prevent gas and electrolyte escaping.
Storage
Because of its low discharge rate recharging is not necessary until approx. 5 months
storage at 20C.

Recombination principle
With sealed batteries the principle of internal recombination is used:

The graph shows the recommended

The oxygen, which is produced in the positive plate during charging causing an oxida-

charge voltages (per cell) as a

tion process which occurs at the negative plate. Through various interim stages lead

function of the operating tempera-

sulphate is produced which is constantly converted to active mass by the charging cur-

ture.

rent and releases water. This creates a closed water regeneration cycle. By using special alloys with a high electrode potential the formation of hydrogen at the negative

Recombination principle of a sealed

electrodes is almost entirely suppressed.

lead-acid battery.

The recombination principle reliably reduces water loss and the escape of electrolyte
gases. Should excess gases be produced through overcharging or misuse, these can
escape through a vent.

C 50

With continuous battery power supply and float charge with occasional discharges and
an operating temperature of 20C a service life of 10 to 12 years can be reached. The
OGi bloc dry / OGiV batteries are maintenance-free throughout their entire service life.
An additional feature is their simple assembly. As the batteries are delivered in a filled

Attributes

30

Zmiany temperatury

40

10

20
0
- 10
- 20
- 30
- 40
2.1

2.2

2.3

2.4

2.5

Napicie adowania na ogniwo V

and charged state they are ready for immediate use.


Dieser Text ist ein Blindtext. Wir
mchten Ihnen damit einen Ein-

Charging

druck von der Gestaltung und


Wirkung des Werbemittels genau

In practice continuous voltage charging has become generally accepted for continuous
standby power supply. Using this method of charging the battery can be charged at either 2.25 V/ cell or 2.35 V/cell charging voltage. A complete recharge is also possible

vermitteln, ohne dabei bereits


eine Diskussion ber Textdetails
auszulsen und weiter.

at a voltage of 2.25 V/cell. A charging current limit is not necessary up to a charging


voltage of 2.35 V/cell. The battery room ventilation corresponds to EN 50 272-2/
DIN VDE 0510 part 2.
The absolutely gas-tight construction allows battery operation in both horizontal and
vertical positions.

Advantages
Operation also possible outside special battery rooms
Installation and operation in any position
Compatible with all existing installations (standard dimensions)
Low self-discharge rate
The pole bushing is gas tight to prevent electrolyte leakage or escape of

Recycling of old battery installations


Lead and NC battery installations are recycled in Germany by Hoppecke according
to the corresponding environmental protection requirements.
The Hoppecke branches are happy to provide information.

gas throughout its service life.

C A PA C I T I E S , D I M E N S I O N S A N D W E I G H T S

Capacity
C10
at
20C

Voltage
per
block

Dimensions (in mm)

Total
weight
with
electrolyte

Pole
pairs

Type
Length

Width

Height

Number
of
cells
per
element

Discharge current in amperes


with final discharge voltage
in volts per cell

1.6 V/C 1.70 V/C 1.74 V/C 1.78 V/C 1.8 V/C
10
20
1h
3h
10 h

OGi bloc dry / OGiV


OGi bloc dry 12 V 30*
OGi bloc dry 12 V 40*
OGi bloc dry 12 V 55*
OGi bloc dry 12 V 65*
OGi bloc dry 12 V 100 *
6 V 1 OGiV 18

Ah
30
40
55
65
100
18

V
12
12
12
12
12
6

mm
234
234
357
357
493
115

mm
178
178
178
178
178
178

mm
215
215
215
215
215
285

kg
16,5
18,5
28,5
30,5
41,0
8,5

pcs.
1
1
1
1
1
1

pcs.
6
6
6
6
6
3

69
103
138
172
220
37.2

30
45
60
75
107
18.4

17
26
35
44
62
11.6

7
10
14
17
26
5

3.0
4.0
5.5
6.5
10.0
1.8

6 V 2 OGiV 36
6 V 3 OGiV 54

36
54

6
6

115
205

178
178

285
285

11,8
17,9

1
1

3
3

74.4
111.6

36.8
55.2

23.2
34.8

10
15

3.6
5.4

6
6
6
6
6
6
4
4

72
90
108
128
160
192
224
256

6
6
6
6
6
6
4
4

205
285
285
285
285
285
252
252

178
177
177
232
232
232
232
232

285
285
285
335
335
335
335
335

21,2
27,3
30,7
41,2
46,9
52,7
42,2
46,1

1
1
1
1
1
1
1
1

3
3
3
3
3
3
2
2

148.8
186
223.2
264
330
396
462
528

73.6
92
110.4
136
170
204
238
272

46.4
58
69.6
84
105
126
147
168

20
25
30
36
45
54
63
72

7.2
9.0
10.8
12.8
16.0
19.2
22.4
25.6

V
V
V
V
V
V
V
V

4
5
6
4
5
6
7
8

OGiV 72
OGiV 90
OGiV 108
OGiV 128
OGiV 160
OGiV 192
OGiV 224
OGiV 256

* DIN 40741 does not apply to these types

Length

Length

Width

Width

Width

Length
H

Following technical documentations are available:


Using instructions
Installation instructions

HOPPECKE
Batterien

Sales & Administration


Accumulatorenwerke HOPPECKE Carl Zoellner & Sohn GmbH & Co KG
P.O.Box 11 40 59914 Brilon Hotline 02963/61-0 Fax 02963/61-449
e-mail: [email protected] www.hoppecke.com

Form OGi bloc dry/OGiV E/10.00/10.00/5 H All details in this brochure are based on state-of-the-art technology. Our products are subject to constant development. We therefore reserve the right to make changes.