SikaWrap-230 C PDF
SikaWrap-230 C PDF
SikaWrap-230 C PDF
Edition 13/6/2006
Identification no:
02 04 01 02 001 0 000025
SikaWrap -230 C
SikaWrap-230 C
Construction
Characteristics /
Advantages
Product Data
Form
Fiber Type
Fabric Construction
Packaging
Fabric length / roll
1 roll in cardboard box
Fabric width
50 m
300 / 600 mm
SikaWrap -230 C
1/3
Storage
Storage Conditions /
Shelf Life
Technical Data
Areal Weight
Fiber Density
1.76 g/cm3
Mechanical / Physical
Properties
Dry Fiber Properties
Tensile strength:
4300 N/mm2 (nominal).
Tensile E-modulus:
238000 N/mm2 (nominal).
Elongation at break:
1.8% (nominal).
Laminate Properties
Laminate thickness:
1.0 mm per layer (impregnated with Sikadur-330).
Ultimate load:
350 kN/m width per layer (at typical laminate thickness of 1.0 mm).
Tensile E-modulus:
28.0 kN/mm2 (based on typical laminate thickness of 1.0 mm).
Note:
The above values are typical and indicative only.
The achievable laminate properties obtained from tensile test are dependant on
the impregnating/laminating resin used and the type of tensile testing procedure.
Apply material reduction factors according to the relevant design standard.
Design
Design strain:
This value is dependent on the type of loading and must be adapted according
to the relevant design standards.
System Information
System Structure
The system configuration as described must be fully complied with and may not
be changed.
Concrete primer - Sikadur-330.
Impregnating / laminating resin - Sikadur-330.
Structural strengthening fabric - SikaWrap-230 C.
For detailed resin properties, fabric application details and general information,
refer to Sikadur-330 Product Data Sheet.
Application Details
Consumption
Substrate Quality
Specific requirements:
Minimal substrate tensile strength: 1.0 N/mm2 or as specified in the strengthening
design.
Substrate Preparation
SikaWrap -230 C
2/3
Application Instructions
Application Method / Tools
The fabric can be cut with special scissors or razor knife. Never fold the fabric!
Refer to Sikadur-330 Product Data Sheet for impregnating / laminating
procedure.
Notes on Application /
Limitations
Construction
All technical data stated in this Product Data Sheet are based on laboratory tests.
Actual measured data may vary due to circumstances beyond our control.
Local Restrictions
Please note that as a result of specific local regulations the performance of this
product may vary from country to country. Please consult the local Product Data
Sheet for the exact description of the application fields.
For information and advice on the safe handling, storage and disposal of chemical
products, users should refer to the most recent Material Safety Data Sheet
containing physical, ecological, toxicological and other safety-related data.
Legal Notes
The information, and, in particular, the recommendations relating to the application
and end-use of Sika products, are given in good faith based on Sikas current
knowledge and experience of the products when properly stored, handled and
applied under normal conditions in accordance with Sikas recommendations. In
practice, the differences in materials, substrates and actual site conditions are
such that no warranty in respect of merchantability or of fitness for a particular
purpose, nor any liability arising out of any legal relationship whatsoever, can be
inferred either from this information, or from any written recommendations, or
from any other advice offered. The user of the product must test the products
suitability for the intended application and purpose. Sika reserves the right to
change the properties of its products. The proprietary rights of third parties
must be observed. All orders are accepted subject to our current terms of sale
and delivery. Users should always refer to the most recent issue of the local
Product Data Sheet for the product concerned, copies of which will be supplied
on request
SikaWrap -230 C