TABLE OF CONTENTS
Mounting Recommendations for Sensors includes best practices for in-line and tank mounting............................4-5
Insertion Sensor Mounting including tees, low flow cells, handrail mounting, floating balls,
jet spray cleaner, mounting adapters, and process connectors.............................................................................6-18
Retraction Assemblies including ball valve kits, retraction assemblies
for higher pressures, and a rotary retraction unit ...............................................................................................19-27
Instrument Mounting with mounting brackets for wall, pipe, or panel mount....................................................28-30
Wiring Accessories includes best practices for cable lengths. Also includes junction boxes,
extension cables, VP connector cables and cable glands ....................................................................................31-37
Calibration Accessories with pH buffer solutions and conductivity standard solutions
Also included is a conductivity validation unit, a pH benchtop calibration unit,
a pH simulator, and VP plug simulator for pH and conductivity..........................................................................38-40
Flow Accessories including rotameters and a constant head flow controller.......................................................41-42
Tags for Sensors and Instruments ............................................................................................................................43
Sample Cooler.........................................................................................................................................................43
Special Parts and Assemblies including examples of customer requested panels with sensors,
flow cells, instruments, and sample cooling system mounted for easy installation.............................................44-45
Certificates for Sensors, Instruments and Chemicals including Certificate of Calibration,
Electronic Calibration, Loop Calibration, & Material Certificates. .............................................................................46
Index for quick and easy searching for parts by number or description....................................................................47
Figure 1. The 3900 general purpose pH sensor is offered with 1 inch MNPT
threads in two locations: one on the process end and one on the cable end. It also
has a 3/4 MNPT process end thread.
Ordering Information
Sensors mounted in
tees and flow cells:
> Air bubbles accumulating on sensors will cause erroneous or erratic readings.
Figure 4. pH sensor recommended mounting orientation. pH sensors should be mounted at least 10 from the
horizontal to ensure correct measurement. Sensors can
also be mounted vertically.
Measured Conductivity
Metal Pipe
True
Conductivity
Plastic Pipe
3/4 to 1 Toroidal
Sensor diameter
Distance to Wall
Figure 7. The measured toroidal conductivity value can be
affected when installed close to a pipe wall.
Incorrect Installation
Correct Installation
The mounting parts contained in this section include inline tees, low flow cells, a handrail mounting assembly, a
floating ball system, a jet spray cleaner, mounting
adapters, and process connectors. The in-line tees are
offered in various configurations to assist in easy sensor
insertion and removal without twisting cables. The low
flow cells are available for sidestream samples with 1/4"
OD tubing. The handrail mounting assembly is available
with all the parts needed to install a sensor into a pond
MEASUREMENT
TYPE
pH and ORP
389, 396, 396P, TF396, 3300HT, 3500, 3900, Hx338, 3800, RB546
Conductivity
140, 400, 228
Dissolved Oxygen
499ADO, 499ATRDO
Ozone
499AOZ
Chlorine
499ACL, 498Cl
* Sensors with integral cable or VP connector can be used.
IN-LINE TEES
In-Line Tees
23567-00
Size
915240-03
915240-04
1.5"
2.0"
1.0" thread
Material
1.5" socket
.75" threads
CPVC, Schedule 80
915240-05
1.0" threads
1.5" threads
PVC, Schedule 80
Buna N
Conductivity
150
Dissolved Oxygen
499ADO
499ADO
Ozone
499AOZ
499AOZ
Chlorine
499ACl
499ACl
*Note: All sensor models noted in this graph are listed with integral cables.
The sensor models with the VP connectors can also be used.
F (C)
150 (1136)
150 (65)
128 (984)
160 (71)
102 (805)
170 (77)
80 (653)
180 (82)
57 (494)
200 (93)
48 (432)
210 (99)
IN-LINE TEES
Tees with union adapters offer quick and easy access and eliminate damage from cable twisting.
Figure 14. 1 in. tee with 1 in. socket process connection (PN 23567-00)
shown with a Model 499A amperometric sensor. The tee assembly is offered with
a sensor mounting adapter that allows the user to remove the sensor without twisting
the cable.
Figure 17. 2 in. tee with , 1, or 1 in. threaded process connections (PN
915240-03, -04, -05 respectively) shown with a Model 499A amperometric
sensor. The tee assembly is offered with a sensor mounting adapter that allows the
user to remove the sensor without twisting the cable.
PN 24091-00
PN 24091-01
Process Connection
Wetted Materials
PN 24091-02
Maximum Temperature
Maximum Pressure
316 SST
158F (70C)
Consult Factory
Consult Factory
1 inch
1 inch
3/4 inch
1 inch
3/4 inch
Special features
None
None
RB-546
Conductivity Sensors
400, 400 VP
400, 400 VP
499ATrDO, 499ADO
499ADO
499A DO
Ozone
499AOZ
Chlorine
499ACL
498CL, 499ACL
Dissolved Oxygen
*Note: All sensor models noted in this graph are listed with integral cables. The sensor models with the VP designation can also be used.
HANDRAIL MOUNTING
Wetted Materials
Temperature Rating
PVC
NA
NA
NA
NA
Compatible Sensors*
pH and ORP Sensors
499ADO**
Jet Spray Cleaner (see pg 13)
* Note: All sensor models noted in this graph are listed with integral cables. The sensor models with the VP
connector can also be used.
** If used with the Handrail Mounting Assembly in a tank, the correct measurement can only be made if there is a
continuous flow or movement past the membrane of the sensor. These sensors will not operate properly in
standing liquid.
*** 1 1/2 inch pipe not supplied in these systems.
Figure 26. Photo on left shows sensor being dangled into the pond, an incorrect installation. Photo on
right shows correct sensor mounting sensor is threaded into a pipe conduit while cable is run through the
pipe of the Handrail Mounting Assembly.
10
Figure 27. HRMS-01 shown with usersupplied 1-1/2" pipe (top) and assembled (bottom).
Figure 28. Handrail Mounting Assembly (PN 11275-01) shown with Model 499A Dissolved Oxygen Sensor.
11
Description
BB11-01
BB11-03
12
The jet spray cleaner is intended for use with pH, ORP, or
oxygen sensors. It directs a spray of air, water, or other
cleaning fluid at the end of the sensor flushing away
suspended solids that have accumulated there. The
cleaner can be used only if the sensor is installed in a
tank or basin. It is not suitable for in-pipe installations.
Cleaning frequency and spray duration is controlled by
an interval timer in the analyzer. During cleaning the
analyzer can be programmed to hold the last reading,
thus avoiding spurious outputs and relay actions. Hold
can be continued beyond the end of the cleaning
Timer: supplied By
user or uTilize
Timer funcTion
inside rosemounT
AnAlyTicAl
insTrumenTs
Process Connection
Wetted Materials
Maximum Pressure
Compatible sensors*
pH and ORP
Chlorine, dissolved
oxygen, and ozone
*Note: All sensor models noted in this graph are listed with integral
cables. The sensor models with the VP designation can also be used.
13
Mounting
Adapters
ADAPTER
23242-02
23242-03
2001990
Materials of
Construction
316 SST,
PEEK, Viton
316 SST,
PEEK, Viton
CPVC, PEEK,
Viton
Process Connection
1-1/2" MNPT
1-1/2" MNPT
2" MNPT
Sensor Adapter/
Union Thread Size
Temperature,
Maximum
392F (200C)
392F (200C)
100F(38C) at
100 psig (791 kPa abs)
OR
185F (85C) at
45 psig (412 kPa abs)
Pressure,
Maximum
295 psig
295 psig
(2135 kPa abs) (2135 kPa abs)
100 psig
(791 kPa abs)
389, 396P
3500, 3900
228-21
228-20
228-21
*Note: Most sensor models noted in this graph are listed with integral cables. The
sensor models with the VP designation can also be used.
A
Sensor*
396P
389
3900
3500
A Dimension
inches
mm
3.5
88.9
3.75
95.2
4.5
114.3
5.5
139.7
*The VP connector
versions can also
be used.
14
ADAPTER
Materials of
Construction
9320057
PVC, Sch 80
Process Connection
1" FNPT
Sensor Adapter/
Union Thread Size
1" FNPT
Temperature,
Maximum
Ambient
15
389, 396P,
3500, 3900
-
Dissolved Oxygen
499ADO
Ozone
499AOZ
Chlorine
499ACL
Mounting Adapters
ADAPTER
S10021 (SQ8940)
SQP-10098-LQD*
SQ 10904A & B
Materials of Construction
316 SST
304 SST
1.5" Tri-Clamp
2" Tri-Clamp
PG 13.5
1"
1" FNPT
3800, Hx338
Process Connection
Sensor Adapter/Union Thread Size
Compatible Sensor Models**
pH and ORP
Conductivity
Dissolved Oxygen
Hx438
* Formerly PN 23513-00
**Note: Most sensor models noted in this graph are listed with integral cables.
The sensor models with the VP connection can also be used.
16
Process Connectors
ADAPTER
Materials of Construction
O-Ring Material
Process Connection
Sensor Tube OD
Compatible pH and
ORP Sensors
PN 23166-00
PN 23166-01
PN 9510066
SQP-10098-LQD**
Titanium
Nylon
EPDM
Polyethylene
Viton
1" MNPT
1" MNPT
1" MNPT
2" Tri-Clamp
*Note: Most sensor models noted in this graph are listed with integral cables. The sensor models with the VP designation can also be used.
**Formerly PN 23513-00
17
Figure 43. Metal process connector (PN 23166-00 [316 SST] or PN 23166-01 [titanium]) shown with
TUpH Model 396 pH sensor. This process connector can be used for all 396, 398, and 3300HT sensor
installations. Also, it must be used for 396R, 398R, and 3400HT installations with or without a ball valve. See
ball valve section for more information.
18
RETRACTION ASSEMBLIES
MEASUREMENT
TYPE
pH and ORP
385+, 396, 396P, 396R, 398, 398R, 3300HT, 3400HT
Conductivity
228, 402
See following pages for retractable mounting options.
19
Ball Valve
Kits
Process Connections
316 SST
316 SST
Wetted Materials
Temperature Rating
32-212F(0-100C)
32-212F(0-100C)
Pressure Rating
Maximum Retraction
Pressure
Compatible
Sensor Models*
pH and ORP
Conductivity
402
Other information
* All sensor models noted in this graph are listed with integral cables. The sensor models with the
VP connector can also be used.
**Process connector is included with the 385 and 385+ sensors
Short insertion
Long insertion
Figure 48. Retractable sensors have the distinct advantage of having an adjustable
insertion depth. Sensor tubes can be installed with a short (top photo) or a longer
(bottom) insertion. See sensor model information for more about sensor tube lengths.
20
Conductivity sensors
should be mounted
between 0 and -30
degrees from the
horizontal
Figure 49. Examples of sensor mounting using a ball valve
retraction kit connected to a standard pipe tee, pipe Y, or
pipe weldolet.
To retract a sensor:
1. Loosen nut
4 . Remove retraction
chamber plus sensor
21
mm/in
mm/in
SENSOR TUBE
LENGTH
327.7/12.9
586.2/23.1
21 in.
660.0/27.4
954.5/37.58
36 in.
Figure 52. 1 in. FNPT Ball Valve Kit (PN 23240-00) shown with process connector (sold separately) and TUpH Model 396R
pH sensor. Ball valve kit includes a 1 in. full port ball valve, a 1 in. FTP to 1 in. FTP reducer (which serves as the retraction
chamber) and a 1 in. close nipple that connects the reducer to the ball valve. A connector (PN 23166-00 or 23166-01) is required
to connect sensor to the reducer.
Process Connector
PN 23166-00 or -01
(sold separately) is
required to connect the
sensor tube to the ball
valve kit .
22
Figure 54. 1 in. MNPT Ball Valve Kit (PN 23765-00 or 23765-01) shown with retraction kit and Endurance Model 402
conductivity sensor. Ball valve kit includes a 1 in. full port ball valve, a 1 in. nipple, and a retraction chamber.
Model
A Dimensions
Minimum*
402-11
402-12
402-13
402-14
396R-21
398R-21
3400HT-21
396R-25
398R-25
3400HT-25
inches
3.21
2.34
2.36
3.89
2.0
2.0
2.0
2.0
2.0
2.0
mm
82
59
60
99
50.8
50.8
50.8
50.8
50.8
50.8
B Dimensions
C Dimensions
Maximum
inches
5.34
4.47
4.49
4.91
12.12
12.12
12.12
26.62
26.62
26.62
mm
136
114
114
125
307.85
307.85
307.85
676.15
676.15
676.15
inches
18.13
17.33
17.33
18.83
21
21
21
36
36
36
mm
460.5
440.2
440.2
478.3
533.4
533.4
533.4
914.4
914.4
914.4
inches
1.19
1.19
1.19
1.19
1.0
1.0
1.0
1.0
1.0
1.0
mm
30.2
30.2
30.2
30.2
25.4
25.4
25.4
25.4
25.4
25.4
Retraction Chamber
114" nipple
23
Process Connection
1.5" MNPT
1.5" MNPT
Wetted Materials
392F (200C)
392F (200C)
392F (200C)
295 psig (2036 kPa)
266F (130C)
35 psig (241 kPa)
Compatible Toroidal
Conductivity Sensors
Model 228
Model 228
Compatible Contacting
Conductivity Sensors
24
25
PASVE Specifications
Process Connections
Maximum Operating
Temperature
482F (250C)
inch
Compatible pH Sensors
26
27
INSTRUMENT MOUNTING
TWO-WIRE INSTRUMENTS
FOUR-WIRE INSTRUMENTS
5081 Transmitter
56 Analyzer
1066 Transmitter
1056 Analyzer
> Single or dual input analyzer.
WIRELESS INSTRUMENTATION
6081
Remote locations and installation
costs are no longer barriers to getting
information you require for critical
applications.
1057 Analyzer
> Three-input analyzer.
> Choose from pH/ORP/ISE or
Contacting Conductivity/
Resistivity, in any combination.
28
Mounting part
23820-00
Bracket
23820-01
Bracket Dimensions
316 SST
U-Bolt
SST
U-Bolt Dimensions
SST
Compatible Instruments
Figure 64. These two graphics are examples of pipe or wall mounting a 6081 instrument using
either of the mounting bracket kits. On the left is an example of the instrument mounting onto a
pipe. On the right, the instrument uses the kit to mount onto a wall. Other Rosemount Analytical
instruments can be mounted similarly.
29
4.0
102 mm
2.8
71 mm
1.2
30.5 mm
1.2
30.5 mm
6.5
165 mm
0.85
22 mm
3.0
76 mm
0.85
22 mm
3.0
76 mm
232
9.1
33.5
1.3
130
5.1
165
6.5
SIDE VIEW
30
WIRING ACCESSORIES
> Long cable distances may degrade the signal; for best
performance, install long cable runs in a noise-free
environment.
> For contacting conductivity sensors, long cable runs
will result in some loss of linearity.
> Consider an Emerson Wireless solution instead.
Mount the analyzer within standard cable length of
the sensor and send the signal wirelessly to the
control room. Emerson offers wireless pH and conductivity instruments as well as the THUM, which
converts any Rosemount Analytical HART instrument
into a wireless device. All wireless instruments require
Sensor
Standard
499ADO
25 ft (7.6m)
200 ft (61.0m)
Junction Box
Prepped
Unprepped
23550-00
23747-00
9200275
498CL or 499ACL
25 ft (7.6m)
200 ft (61.0m)
23550-00
23747-00
9200275
499AOZ
25 ft (7.6m)
200 ft (61.0m)
23550-00
23747-00
9200275
Junction box
PN 23550-00
Chlorine, Dissolved
Oxygen or Ozone
Sensor
Standard sensor
cable or VP cable
(50 ft (15m) max)
Analyzer
Extension cable
31
WIRING ACCESSORIES
Conductivity Sensors
Sensor to Analyzer Separation Distances
Sensor Cable Length
Measurement
Contacting
Conductivity
Toroidal
Conductivity
Sensor
Standard
Recommended
maximum distance
between sensor and
instrument*
Optional
200 ft (61.0m)
200 ft (61.0m)
200 ft (61.0m)
200 ft (61.0m)
200 ft (61.0m)
100 ft (30.5m)
200 ft (61.0m)
Extension Cable
Junction Box
Prepped
Unprepped
Included
23550-00
23550-00
Included
23550-00
23550-00
Included
23747-00
23747-00
23747-00
23747-00
23294-04
23294-04
23909-00
9200275
9200275
9200275
9200275
9200276
9200276
Analyzer
Contacting
Conductivity
Sensors
Standard sensor
cable or VP cable
(50 ft (15m) max)
Extension cable
Junction box
PN 23550-00
Toroidal
Conductivity
Sensors
Standard sensor
cable or VP cable
(50 ft (15m) max)
Extension cable
Junction box
PN 23550-00
Maximum recommended distance between sensor and instrument is 100 ft (30.5m) to 200 ft
(61.0m) depending on the sensor model. See chart for more information.
Contacting or Toroidal
Conductivity Sensors with
sensor mounted junction box
Extension cable
32
WIRING ACCESSORIES
Extension Cable
Sensor
Standard
No preamp
in the sensor
15 ft (4.6m)
200 ft (61.0m)
25 ft (7.6m)
200 ft (61.0m)
23550-00
23646-01
9200273
200 ft (61.0m)
23646-01
9200273
pH Sensors
Preamplifier in Sensor
Mounted Junction Box
Optional
Recommended
maximum distance
between sensor and
instrument*
No Cable;
use extension cable
Junction Box
23555-00
23646-01
(contains preamp)
Standard sensor
cable or VP cable
(50 ft (15m) max)
Extension cable
Junction box PN 23555-00
WITH preamplifier
Standard sensor
cable or VP cable
(50 ft (15m) max)
Extension cable
Junction box PN 23550-00
with extension board
Extension cable
33
Prepped Unprepped
9200273
34
2002565
U-Bolt
SST
U-Bolt Dimensions
SST
11.5 inches
292 mm
4.4 inches
112 mm
35
VP Connector Cables
pH and ORP Sensor Cables
The VP8 connector cable is compatible with the
following sensors: 3300HTVP, 3400HTVP, 3500VP,
3900VP, 389VP, 396VP, 396PVP, 396RVP, 398VP,
398RVP, HX338, 3800VP.
Part Number
24281-02
2.5
0.8
24281-05
1.2
24281-06
10
3.0
24281-00
15
24281-07
20
6.1
24281-01
25
7.6
24281-08
30
9.1
24281-03
50
15.2
24281-04
100
30.5
VP6 Cable
for conductivity,
dissolved oxygen, ozone
& chlorine sensors
Part Number
Feet
Meters
23747-02
10
3.0
23747-03
50
15.2
23747-04
1.2
23747-05
2.25
0.7
23747-06
2.5
0.8
23747-07
15
4.6
23747-08
20
6.1
23747-09
25
7.6
23747-10
30
9.1
23747-11
100
30.5
24287-00
10
3.0
24287-01
20
15.2
Figure 74. VP6 connector cables can be used with conductivity and amperometric sensors with a VP designation.
499ADO-VP and 400VP (bottom) shown.
36
EXTENSION CABLES
398R/VP
396R/VP 398R/VP
23646-01
9200276
Unprepped
9200334
23294-00
Unshielded, Prepped
23294-04
23294-05
23747-00
Prepped
23909-00
Prepped
24289-00
410VP
Amperometric*
400 & 400VP, 401,
402 & 402VP, 403
& 403VP, 404
9200275
222
245
Cable Part
Number
242
150
Conductivity
499ACl, 499ADO
499AOZ,
499ATRDO
9200273
396P/VP
3500/VP
Cable Description
396/VP / 398/VP
3400HT/HTVP
389/VP
3300HT/HTVP
385+
prepared with the cable jacket and all of the wires stripped
and ready for quick installation. The use of factoryprepped cables is strongly recommended. All extension
cables can be ordered at user specified length.
3900/VP
X
X
X
X
X
X
X
X
Cable Glands
Use cable glands to seal the cable where it enters the
analyzer or junction box. Cable glands also prevent the
weight of the cable from pulling on and dislodging
wiring connections in the analyzer. Cable gland kit PN
23554-00 provides 5 cable glands that fit all Rosemount
Analytical instruments and junction boxes.
37
CALIBRATION ACCESSORIES
38
CALIBRATION STANDARDS
pH Buffer Solutions
Emerson offers pH 4.01, pH 6.86, and pH 9.18 NIST
buffer solutions that meet most pH calibration requirements. Accuracy is 0.02 pH at 25C (77F). A chart listing
the pH of the buffer at other temperatures is provided on
the label.
Part Number
Description
Size
Color Code
9210012
16 oz (473 ml)
Pink
9210013
16 oz (473 ml)
Clear
9210014
16 oz (473 ml)
Clear
pH 4 buffer solution
16 oz (473 ml)
Red
Red
pH 7 buffer solution
16 oz (473 ml)
Green
Green
905-3506
905-582517
905-3501
905-582521
905-3505
905-582525
pH 10 buffer solution
16 oz (473 ml)
Blue
Blue
8 oz (237 ml)
NA
R508-8oz
Conductivity Standards
Emerson offers a variety of conductivity standards in
both 16 oz (473 mL) and 1 gal (3.8 L) sizes. To determine
the best standard to use, consult the analyzer product
data sheet and choose a standard whose conductivity is
in the recommended range for the cell constant.
Part Number
Size
Color Code
05010781899 (SS-6)
200 S/cm
16 oz (473 ml)
Red
05000705464 (SS-1)
1409 S/cm
16 oz (473 ml)
Blue
05010782468 (SS-5)
1000 S/cm
16 oz (473 ml)
Yellow
05010782147 (SS-7)
5000 S/cm
16 oz (473 ml)
Violet
05010797875 (SS-6A)
200 S/cm
1 gallon (3.8 L)
Red
05000709672 (SS-1A)
1409 S/cm
1 gallon (3.8 L)
Blue
05010783002 (SS-5A)
1000 S/cm
1 gallon (3.8 L)
Yellow
05010782026 (SS-7A)
5000 S/cm
1 gallon (3.8 L)
Violet
39
CALIBRATION ACCESSORIES
Handheld pH Simulator
The handheld pH simulator PN S10104 (SQ7428)
supplies switch-selectable pH 4, 7, and 10 inputs to an
analyzer. Two other switches allow the user to simulate
a cracked glass membrane and a coated reference junction. The simulator is compatible with any Rosemount
Analytical pH instrument. The unit is battery operated.
Consult the factory for more information.
40
FLOW ACCESSORIES
Flow
Rate*
Recommended
Valve Rotameter
PN 9390004 or PN 196-898754
499A CL
PN 196-898754
499A DO
PN 9390004
499A OZ
PN 9390004
Rotameter Specifications
PN 9390004
Range of Flow Required
PN 196-898754
Process Connection
Maximum Pressure
130F (54C)
130F (54C)
Wetted Parts
Maximum Temperature
41
Inlet pressure
Temperature
32 - 122F (0 - 50C)
42
SAMPLE COOLERS
Uncooled sample
Temperature: 600 F (315C) max
Pressure: 1500 psig (10,440 Kpa abs)
Cooled sample
Operating Temperature Range: 32 F to 203 F (0C to 95C)
Preferred: 70F to 90 F (21 C to 32 C)
Cooling Water
Temperature: 122F (50C) maximum
Pressure: 200 psig (1480 Kpa abs) maximum
Contact factory for more information.
Figure 82. Sample Cooler example
43
44
45
OTHER CERTIFICATES
Certificate of Calibration
TO:
RCM or SO #
Line
Model Number/ Customer
Item
Part Number
1
5081-C-HT-20-60-99CC
46
Serial Number
A10-1220470-017
Tag Number
40-AT-402
3200HP-01-99CC
Refer. Manual
N/A
A10-1218201-008
40-AT-401
5081-P-HT-21-69-99CC
0-14pH1400mV
N/A
A10-1226016-001
N/A
400-11-60-99CC
0-50S
0.01/cm
J09-698212
N/A
This certifies that the furnished materials have been manufactured and tested in accordance with all
applicable product specifications under compliance of our Quality System. Rosemount Analytical is certified
to ISO 9001:2008 by Det Norske Veritas Certification # 09242-2006-AQ-HOU-ANAB and complies with
Standard CSA Z299.3. Our calibration system is maintained in accordance with all requirements of
ANSI/NCSL Z540-1-1994, American National Standard for Calibration System Requirements, and is
traceable to the National Institute of Standards and Technology (NIST).
All products, including packaging, are free of Mercury and are certified to contain no hazardous materials or
wood products. Records of inspection, testing and other required supporting documentation are on file and
available for your examination upon request.
QA INSPECTOR
Title
42-6050
Rev. Date: Aug. 3, 2009
Date:
P.O.#
This certifies that the furnished materials have been manufactured and tested in accordance with all
applicable product specifications under compliance of our Quality System. Rosemount Analytical is certified
to ISO 9001:2008 by Det Norske Veritas Certification # 09242-2006-AQ-HOU-ANAB and complies with
Standard CSA Z299.3. Our calibration system is maintained in accordance with all requirements of
ANSI/NCSL Z540-1-1994, American National Standard for Calibration System Requirements, and is
traceable to the National Institute of Standards and Technology (NIST).
All products, including packaging, are free of Mercury and are certified to contain no hazardous materials or
wood products. Records of inspection, testing and other required supporting documentation are on file and
available for your examination upon request.
Units Under Test (UUT)
Line
Item
1
2
Calibrated Range:
Instrument/Sensor
Model Number
1056-02-21-38-AN-99LC
225-07-56-99CB-99LC-99Q8
Standards (STD):
Standards
KCL ( 650001 )
RC-20
THERMOMETER
H50Y35
After
Calibration
STD
Value
111.624mS
pH Sensor Only
Verified Range:
0-100mS
Customer
Part Number
N/A
N/A
Serial
Number
J09-694219
J09-694079
Tag
Number
N/A
N/A
Asset No. /
NIST Report No.
Lot
Number
Calibration
Date
N/A
2802
1808/48380-2
1047
G30422
N/A
N/A
N/A
N/A
08-07-09
02-27-09
09-09-09
UUT
Reading
111.700mS
SLOPE =
Tolerance
1%
1%
1%
Deviation
.07
%
%
%
mV/pH @ 25 C
In/Out
of Tol.
IN
STD Temp.
Reading
21.5
C
C
C
OFFSET=
N/A
Cell
Constant
N/A
3.3000
Calibration
Due/Expiration
Date
N/A
02-07-10
02-27-10
01-09-10
UUT
Tolerance
1C
1C
1C
mV
UUT Temp
Reading
21.5
C
C
C
Note: UUT and RTD must be within tolerance specified of the Standard Value
K=
1.0
Test Results:
DATE:
PO #:
Range
0-20mS
42-6048
Rev. Date: Aug. 3, 2009
INDEX
Part Number
2001492
2001990
2002011
2002526
9200245
9200273
9200275
9200276
9200334
9210012
9210013
9210014
9310102
9320057
9390004
9510066
05000705464
05000709672
05010781899
05010782026
05010782147
05010782468
05010783002
05010797875
11275-01
12707-00
196-898754
23166-00
23166-01
23240-00
23242-02
23242-03
23294-04
23294-05
23311-00
23311-01
23550-00
23554-00
23555-00
23567-00
23646-01
23709-00
23747-00
23747-XX
23765-00
23796-00
Description
Tag
Adapter
Tee
Junction box
Extension Cable
Extension Cable
Extension Cable
Extension Cable
Extension Cable
pH Buffer
pH Buffer
pH Buffer
Nipple
Adapter
Rotameter
Process Connector
Conductivity Standard
Conductivity Standard
Conductivity Standard
Conductivity Standard
Conductivity Standard
Conductivity Standard
Conductivity Standard
Conductivity Standard
Handrail Mounting Assy
Jet Spray Cleaner
Rotameter
Process Connector
Process Connector
Ball Valve Kit
Adapter
Adapter
Extension Cable
Extension Cable
Retraction Assembly
Retraction Assembly
Junction box
Cable Gland Kit
Junction box
Tee
Extension Cable
Junction box
Extension Cable
VP6 Cable
Ball Valve Kit
Retraction Kit
Page
43
14
7
35
32
33, 37
31, 37
37
37
39
39
39
22
15
41
17
39
39
39
39
39
39
39
39
10
13
41
17
17
20
14
14
32, 37
37
24
24
31-33, 34
37
33, 34
7
33, 37
35
37
31, 32, 36
20
20
47
Part Number
23820-00
23820-01
23909-00
23979-00
24035-00
24091-00
24091-01
24091-02
24281-XX
24287-XX
24289-00
905-3501
905-3505
905-3506
905-582517
905-582521
905-582525
915240-03
915240-04
915240-05
9240048-00
9241178-00
99-14
BB11
Calibration Certificate
CVU
Electronic Calibration Cert.
HRMS-01
HRMS-02
Loop Calibration Certificate
Material Certificate
Pasve
R508-8oz
S10021 (SQ 8940)
S10104 (SQ 7428)
S10119
S10240 (SQ 7716)
S10283-LQD
S10290 (SQ 7637)
SQ 10904
SQ 8705
SQP 10081-LQD
SQP-10077-LQD (SQ 10957)
Description
Page
Instrument Mounting Kit
29
Instrument Mounting Kit
29
Extension Cable
32, 37
Conductivity Simulator
40
Rotameter
41
Low Flow Cell
9
Low Flow Cell
9
Low Flow Cell
9
VP8 Cable
36
VP6 Cable
36
Extension Cable
37
pH Buffer
39
pH Buffer
39
pH Buffer
39
pH Buffer
39
pH Buffer
39
pH Buffer
39
Tee
7
Tee
7
Tee
7
Tag
43
Tag
43
Sample Cooler
43
Floating Ball System
12
Certificates
46
Conductivity Validation Unit
38
Certificates
46
Handrail Mounting System
10
Handrail Mounting System
10
Certificates
46
Certificates
46
Retraction Assembly
26
ORP Standard
39
Triclamp
16
pH Simulator
40
Bench Top Calibrator
40
Low Flow Cell
9
Tee Adapter
7
Low Flow Cell
9
Triclamp
16
pH Simulator
40
Special Assembly
44
Overflow Sampler
42
SQP-10098-LQD (formerly
PN 23513-00)
Triclamp
16, 17
ANALYTICAL HEADQUARTERS
Emerson Process Management
Rosemount Analytical
2400 Barranca Parkway
Irvine, CA 92606 USA
T 1.949.757.8500
T 800.854.8257
F 1.949.474.7250
[email protected]
LATIN AMERICA
Emerson Process Management
Rosemount Analytical
10241 West Little York, Suite #200
Houston, TX 77040 USA
T 713.467.6000
F 713.827.3328
EUROPE
Emerson Process Management AG
Blegistrasse 21
CH-6341 Baar-Walterswil
Switzerland
T 41.41.768.6111
T 41.41.761.8740
ASIA- PACIFIC
Emerson Process Management
Asia Pacific Private Ltd.
1 Pandan Crescent
Singapore 0512
Republic of Singapore
Phone: +65.777.8211
Fax: +65.777.0947
RosemountAnalytical.com
Online ordering available.
Emerson Process Management, Rosemount Analytical, PlantWeb, TUpH and ENDURANCE, are marks of Emerson Process Management group of companies. All other marks are the
property of their respective owners.
The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure its accuracy, they are not to be construed as
warranties or guarantees, expressed or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions,
which are available on request. We reserve the right to modify or improve the designs or specifications of such products at any time without notice.
Rosemount Analytical Inc. 2012. All rights reserved. Printed in the U.S.A.
91-6020/rev. C