MITEL
3300 MXe
Standard
3300 MXe
Expanded
3300 MXe
Server
3300 AX
150
350
1,500
5,000
250
Maximum number of
IP phones1
100
300
1,400
5,000
100
100
300
1,000
1,0002
100
50
100
350
350
50
16
24
24
104
400
1,200
(via peripheral cabinets)
192
Maximum number of
analog phones
Shipped with:
1
2
DATA SHEET
Controllers (contd)
3300 CX / CXi
Available MMC Slots
MMC Slots for:
3300 AX
Dual FIM
Quad CIM
Single and Dual T1 /
E1 Quad BRI Quad
DSP Echo Canceller
Quad DSP
Echo Canceller
2 (10 / 100
Base T only)
3 (plus 2
integrated)
3 (plus 2
integrated)
3 (plus 2
integrated)
64
128
128
256
128
16
32
64
64
32
16
16
12
12
6 LS trunks4
4 ONS ports
6 LS trunks
4 ONS ports
6 LS trunks
4 ONS ports
6 LS trunks
4 ONS ports
12
12
12
Dual FIM
Quad CIM
Quad CIM
Single T1 / E1
Single and Dual T1 / E1
Quad BRI
Dual and Quad DSP Quad BRI Quad DSP
Echo Canceller
3300 MXe
Server
3300 MXe
Expanded
2 (Single trunk
modules only)
3300 MXe
Standard
Includes Music-on-Hold (1 source supported), Paging (1 paging zone), System Fail Transfer (2 circuits)
Analog trunks support CLASS Signaling for North America and Latin America
The Analog Line card is available in two variants; the 16 ONS circuit card and the 4 LS trunks & 12 ONS extension card. Note the 4+12 Card supports 4 SFT circuits.
Controllers
3300 CX / CXi
3300 MXe
Standard
3300 MXe
Expanded
3300 MXe
Server
3300 AX
6 (12)
6 (12)
Tone generators
128
128
128
128
32
32
32
32
E2T Channels
64
64
128
256
128
DTMF Receivers
128
128
128
128
IP Networking maximum IP
trunks between controllers
200
200
200
200
200
2000
2000
2000
2000
2000
2000
2000
2000
2000
2000
400
400
400
400
400
Maximum controllers in a
cluster7
250
250
250
250
250
Yes
Yes
Yes
Yes
Yes
20
20
Maximum embedded
voicemail ports8
16
30
30
20
Maximum mailboxes
750
750
750
750
Storage hours
450
450
450
70
100
100
100
100
DATA SHEET
SIP Trunking
Supports G.711 and G.729 compression
SIP Trunking license required for each SIP channel
Supports RFCs
- RFC 3261 SIP Session Initiation Protocol
- RFC 3262 Reliability of provisional responses in
Session Initiation Protocol (SIP)
- RFC 3263 Locating SIP servers
- RFC 3264 An offer answer model with session
description protocol
TDM Connectivity
Peripheral Cabinet
Connects via FIM module, each module supporting
two directly connected peripheral cabinets
12 peripheral interface cards per cabinet
Max 192 analog or DNI ports
Can add an expansion cabinet to a peripheral cabinet
providing a total of 384 ports or 24 peripheral
interface cards
Supports:
DID / loop tie card (4 ccts / card)
DNIC line card (16 ccts / card)
DTMF receiver card (16 ccts / card)
E&M trunk card (4 ccts / card)
LS / GS trunk card (8 ccts / card)
Analog, analog CLASS, analog CLASS / CLIP
line cards (16 ccts / card)
DATA SHEET
Dimensions
3300 Controller
Analog Services
Unit (ASU)
ASU 1.75 in (4.454 cm) (1U)
ASU II 3.3 in (8.4 cm) (2U)
Network Services
Unit (NSU)
1.75 in (4.454 cm) (1U)
Peripheral Cabinet
Height
Width
Depth
19.0 in (48.0cm)
Weight
Analog Services
Unit (ASU and ASU II)
Network Services
Use (NSU)
Peripheral Cabinet
40 to 122F
(4 to 50C)
40 to 122F
(4 to 50C)
40 to 122F
(4 to 50C)
Operational Environment
3300 Controller
Temperature 40 to 122F
(4 to 50C)
Humidity
5%-95% relative
humidity, non
condensing
5%-95% relative
humidity, non
condensing
5%-95% relative
humidity, non
condensing
5%-95% relative
humidity, non
condensing
Max Heat
Dissipation
fully
loaded
Air Flow
Acoustic
Emissions
Conversion factors: One watt is equal to 3.412 BTUs per hour. One ton of refrigeration is equal to 12,000 BTUs per hour or 3.516 Kilowatts, and 0.75 kilowatt-hour is equal to
one ton of refrigeration.
Analog Services
Unit (ASU and ASU II)
Network Services
Use (NSU)
Peripheral Cabinet
Input/
Disconnect
IEC320-C14 Class 1 AC
Receptacle
2 Receptacles on AX and
MXe / MXe Server with
redundant power
IEC320-C14 Class 1 AC
Receptacle
IEC320-C14 Class 1 AC
Receptacle
IEC320-C14 Class 1 AC
Receptacle
Input
Voltage /
Frequency
Rating
100-240 VAC
50 / 60 Hz
100-240 VAC
50 / 60 Hz
100-240 VAC
50 / 60 Hz
102-120 VAC
50 / 60 Hz MP914AA
PSU Variant200-240
VAC
50/60 Hz MP914AD
PSU Variant
ASU 75 W max
ASU II 125 W max
Universal NSU 20 W
R2 NSU 30 W
200 W typical
(ONS and DNI Mix)
300 W typical (all DNI)
540 W Max (input
surge, all DNI)
90-264 VAC
90-264 VAC
90-264 VAC
102-132 VAC
Range
47-63 Hz
67-63 Hz
67-63 Hz
47-63 Hz MP914AA
187-264 Hz MP914AD
Glossary
ACD
ISDN
ASU
LS
BRI
MMC
BTU
MOH
Music on Hold
CAS
MSDN
CCS
NFAS
CIM
NSU
CLASS
OPS
DASSII
PRI
QSIG
Q Signaling Protocol
DNI
RSTP
DPNSS
SIP
DSP
STP
DTMF
VM
Voice Mail
FIM
XNET
Switched Networking
IP
Internet Protocol
www.mitel.com
Global Headquarters
U.S.
EMEA
CALA
Asia Pacific
Tel: +44(0)1291-430000
Fax: +44(0)1291-430400
For more information on our worldwide office locations, visit our website at www.mitel.com/offices
THIS DOCUMENT IS PROVIDED TO YOU FOR INFORMATIONAL PURPOSES ONLY. The information furnished in this document, believed by Mitel to be accurate as of the date
of its publication, is subject to change without notice. Mitel assumes no responsibility for any errors or omissions in this document and shall have no obligation to you as a
result of having made this document available to you or based upon the information it contains.
M MITEL (design) is a registered trademark of Mitel Networks Corporation. All other products and services are the registered trademarks of their respective holders.
Copyright 2008, Mitel Networks Corporation. All Rights Reserved.
GD 392_891 PN 51008713RI-EN