Mitel 3300 Feature Sheet PDF

Download as pdf or txt
Download as pdf or txt
You are on page 1of 8

DATA SHEET

MITEL

3300 IP Communications Platform


Providing feature-rich IP communication and advanced user
applications to corporate local and wide area networks
Controllers
3300 CX / CXi

3300 MXe
Standard

3300 MXe
Expanded

3300 MXe
Server

3300 AX

Maximum number of devices


including software agents1

150

350

1,500

5,000

250

Maximum number of
IP phones1

100

300

1,400

5,000

100

Maximum number of SIP


devices / users

100

300

1,000

1,0002

100

Maximum ACD Agents1

50

100

350

350

50

Maximum 5550 IP consoles

16

24

24

104

400

1,200
(via peripheral cabinets)

192

1 Dual DSP module


(integrated)
AMB
Hard Disk Drive
Power Supply
10 Echo Cancellers

2 Quad DSP modules


(integrated)
AMB
Hard Disk Drive
Power Supply
128 Echo Cancellers

2 Quad DSP modules


(integrated)
AMB
Hard Disk Drive
Power Supply
128 Echo Cancellers

2 Quad DSP modules


(integrated)
RAID Controller
Dual HDD Drives
Dual Power Supplies
256 Echo Cancellers

2 Quad DSP modules


(integrated)
Flash Drive
Power Supply
42 Echo Cancellers

Maximum number of
analog phones
Shipped with:

1
2

Engineering rules apply


Higher limits are currently being qualified

DATA SHEET

Controllers (contd)
3300 CX / CXi
Available MMC Slots
MMC Slots for:

3300 AX

Dual FIM
Quad CIM
Single and Dual T1 /
E1 Quad BRI Quad
DSP Echo Canceller

Quad DSP
Echo Canceller

Single and Dual


T1 / E1 Quad BRI
Quad DSP
Echo Canceller

See CXi Controller Data


connectivity section

2 (10 / 100
Base T only)

Maximum Dual DSP Modules

Maximum Quad DSP modules

3 (plus 2
integrated)

3 (plus 2
integrated)

3 (plus 2
integrated)

Maximum Echo Canceller


Channels

64

128

128

256

128

Maximum G.729a compression


channels (each 32 channels
requires a DSP module)

16

32

64

64

32

Maximum number of NSUs

Maximum number of digital


links (except BRI)

16

16

Maximum Embedded BRI


interfaces (2 channels per
interface)

12

12

Maximum number of Dual FIM


modules

Dual FIM can be used


to connect:

NSU, DSU, Peripheral


Cabinets, Triple FIM
card

NSU, DSU, Peripheral


Cabinets, Triple FIM
card

Analog Main Board3

6 LS trunks4
4 ONS ports

6 LS trunks
4 ONS ports

6 LS trunks
4 ONS ports

Analog Option Module

6 LS trunks
4 ONS ports

Analog Line card slots5

12

Maximum number of CIM


connected ASUs

12

12

10 / 100 / Gig Base T


Ethernet ports

Dual FIM
Quad CIM
Quad CIM
Single T1 / E1
Single and Dual T1 / E1
Quad BRI
Dual and Quad DSP Quad BRI Quad DSP
Echo Canceller

3300 MXe
Server

Maximum embedded BRI


modules

3300 MXe
Expanded

2 (Single trunk
modules only)

Maximum embedded Dual T1 /


E1 digital trunk modules

3300 MXe
Standard

Includes Music-on-Hold (1 source supported), Paging (1 paging zone), System Fail Transfer (2 circuits)
Analog trunks support CLASS Signaling for North America and Latin America
The Analog Line card is available in two variants; the 16 ONS circuit card and the 4 LS trunks & 12 ONS extension card. Note the 4+12 Card supports 4 SFT circuits.

2 MITEL DATA SHEET 3300 IP COMMUNICATIONS PLATFORM

Controllers
3300 CX / CXi

3300 MXe
Standard

3300 MXe
Expanded

3300 MXe
Server

3300 AX

6 (12)

6 (12)

Tone generators

128

128

128

128

Tone detector circuits

32

32

32

Maximum fiber connected


peripheral nodes
(with Peripheral expander)

32

E2T Channels

64

64

128

256

128

DTMF Receivers

128

128

128

128

IP Networking maximum IP
trunks between controllers

200

200

200

200

200

IP Networking total max


IP trunks

2000

2000

2000

2000

2000

SIP trunking total maximum


SIP trunks

2000

2000

2000

2000

2000

SIP trunking max SIP trunks


between peers

400

400

400

400

400

Maximum controllers in a
cluster7

250

250

250

250

250

STP & RSTP

Yes

Yes

Yes

Yes

Yes

Embedded Voicemail ports as


standard

20

20

Maximum embedded
voicemail ports8

16

30

30

20

Maximum mailboxes

750

750

750

750

Storage hours

450

450

450

70

Maximum messages per mailbox

100

100

100

100

Supporting conference, music on hold and paging functions only.


Up to 250 controllers can be clustered as a single system to support over 65,000 IP ports. Mitels System Data Synchronization technology is used to enable feature
transparency across a cluster of controllers.
8 Requires DSP on CX, CXi, MXe and MXe Expanded and additional 4Gb flash drive on AX controller
6
7

IP COMMUNICATIONS PLATFORM MITEL DATA SHEET 3

DATA SHEET

Mitel 3300 CXi Controller Data Connectivity


Integral 16-port powered L2 10 / 100 Ethernet switch
Has additional 10 / 100 / 1000 Ethernet uplink port
Provides connection to additional switch ports
and router
Also has WAN port that is an Internet Gateway
WAN port provides connection to an ISP for Internet
access (e.g., DSL or cable)
WAN port provides NAT and firewall capabilities
WAN port does not support IP networking
Use external router for IP networking
Same as you would with a CX, MXe, AX Controller
Embedded ACD
1,181 agent IDs
Maximum of 350 total logged-in agents
256 paths
Either 64 agent groups (150 agent IDs per group) OR
32 agent groups (500 agent IDs per group)
Embedded Wireless Phones
SpectraLink 802.11b* or Mitel IP-DECT wireless
phones supported
802.11b or IP-DECT access points supported
Custom integration with SpectraLink and IP-DECT
MiNet wireless phones
* 802.11b access points must be SpectraLink SVP compliant

SIP Trunking
Supports G.711 and G.729 compression
SIP Trunking license required for each SIP channel
Supports RFCs
- RFC 3261 SIP Session Initiation Protocol
- RFC 3262 Reliability of provisional responses in
Session Initiation Protocol (SIP)
- RFC 3263 Locating SIP servers
- RFC 3264 An offer answer model with session
description protocol

4 MITEL DATA SHEET 3300 IP COMMUNICATIONS PLATFORM

-RFC 3515 The Session Initiation Protocol (SIP)


refer method
-RFC 2976 The SIP info method
-RFC 3325 Private extensions to the Session
Initiation Protocol (SIP)
-RFC 1321 The MD5 message digest algorithm
-RFC 2833 RTP payload for DTMF digits, telephony
tones and telephony signals (section 3.10)
SIP Line Side
Supports G.711 and G.729 compression
SIP Line license required for each SIP device
connection
Supports RFCs
- RFC 1321 The MD5 message digest algorithm
- RFC 2976 The SIP info method
- RFC 3261 SIP Session Initiation Protocol
- RFC 3262 Reliability of provisional responses
in SIP
- RFC 3263 Locating SIP Servers
- RFC 3265 Specific event notification
- RFC 3311 The Session Initiation Protocol
update method
- RFC 3515 The Session Initiation Protocol
refer method
- RFC 3891 The Session Initiation Protocol
replaces header
- RFC 4028 Session timers in the Session
Initiation Protocol
- RFC 3680 A Session Initiation Protocol event
package for registrations
- RFC 3842 A message summary and message
waiting indication event package SIP
- RFC 2327 SDP: Session description protocol
- RFC 3264 An offer / answer model with SDP
- RFC 2833 RTP payload for DTMF digits, telephony
tones and telephony signals

Digital Trunk Connectivity


Universal NSU (MXe Controller)
Connects to controller via a FIM link
A second NSU can be daisy chained from the first
NSU via CIM (allows two NSUs per FIM link)
Each NSU supports two digital links
Both links in an NSU must run the same protocol
(T1-D4 or MSDN / DPNSS or PRI / QSIG)
Supports:
CAS (T1-D4) digital E&M, digital CO, digital DID, IDA-P
T CCS Primary Rate ISDN, XNET over PRI, QSIG,
MSDN / DPNSS
1 QSIG, Euro ISDN, XNET over PRI, DASSII,
MSDN / DPNSS
R2 NSU (MXe Controller)
Each R2 NSU supports two links
Connects to controller via a FIM link
A second NSU can be daisy chained from the first
NSU via CIM (allows two NSUs per FIM link)
Dual Embedded Digital Trunk Module (MXe / AX)
Each module has two E1/T1 trunk interfaces (links)
Provides PRI / QSIG / T1-D4 / DASS II / DPNSS / IDA-P
protocol through the controller (no NSU required)
Each interface can run a different protocol, either PRI,
QSIG, or T1-D4
Does not support:
Min / Max, NFAS, D-Channel Backup or TDM XNET
(Hybrid XNET is supported)
Single Embedded Digital Trunk Module
(CX / CXi / MXe / AX Controllers)
Each module has a single E1 / T1 trunk interface (link)
Provides PRI / QSIG / T1-D4 / DASS II / DPNSS / IDA-P
protocol through the controller (no NSU required)
Resiliency (switches to secondary controller)

Embedded BRI Module


(CX / CXi / MXe / AX Controllers)
The Embedded BRI module has four Basic Rate
Circuits (total 8 64kbs channels)
Each channel may be configured as either a:
T (trunk) interface for links from a BRI
Central Office (CO)
S (subscriber) interface for connecting up to
eight BRI devices.
Note: S interfaces support only basic call features such as calling number
display for BRI devices (BRI call handling such as Hold or Transfer are
not supported). BRI devices are not line powered from the embedded
BRI module.
Note: This module does not support U interfaces. In North America, we
recommend the BRI NSU (NA) for such applications.

TDM Connectivity
Peripheral Cabinet
Connects via FIM module, each module supporting
two directly connected peripheral cabinets
12 peripheral interface cards per cabinet
Max 192 analog or DNI ports
Can add an expansion cabinet to a peripheral cabinet
providing a total of 384 ports or 24 peripheral
interface cards
Supports:
DID / loop tie card (4 ccts / card)
DNIC line card (16 ccts / card)
DTMF receiver card (16 ccts / card)
E&M trunk card (4 ccts / card)
LS / GS trunk card (8 ccts / card)
Analog, analog CLASS, analog CLASS / CLIP
line cards (16 ccts / card)

Does not support:


Min / Max, NFAS, D-Channel Backup or TDM XNET
(Hybrid XNET is supported)

IP COMMUNICATIONS PLATFORM MITEL DATA SHEET 5

DATA SHEET

Dimensions
3300 Controller

Analog Services
Unit (ASU)
ASU 1.75 in (4.454 cm) (1U)
ASU II 3.3 in (8.4 cm) (2U)

Network Services
Unit (NSU)
1.75 in (4.454 cm) (1U)

Peripheral Cabinet

Height

CX / CXi / MXe / MXe Server


3.5 in (8.9 cm) (2U)
AX 13.35 in (39.90 cm) (7U)

Width

CX/CXi/MXe/MXe Server 17.75 in 17.75 in (45.1 cm)


(45.1 cm) 19 rack mountable (19 rack mountable)
AX 17.4 in (44.20 cm)

17.75 in (45.1 cm)


(19 rack mountable)

18.0 in (45.8 cm)

Depth

CX / CXi 16.5 in (41.9 cm)


MXe / MXe Server 20.25 in.
(51.4 cm)
AX 13.87 in (35.23 cm)

ASU 15.5 in (39.4 cm)


ASU II 13.3 in (33.8 cm)

15.5 in (39.4 cm)

19.0 in (48.0cm)

Weight

CX / CXi 19.8 lb (8.98 kg)


MXe 28 lb. (12.7 kg)
MXe Server 33 lb (15 kg)
AX 39.70 Ib. (18.01 kg)

ASU 10.61 lb. (4.81 kg)


ASU II 14.1 lb. (6.4 kg)

8.41 lb (4.27 kg)

71.8 lb (32.6 kg)

Analog Services
Unit (ASU and ASU II)

Network Services
Use (NSU)

Peripheral Cabinet

40 to 122F
(4 to 50C)

40 to 122F
(4 to 50C)

40 to 122F
(4 to 50C)

19.0 in (48.0 cm)

Operational Environment
3300 Controller
Temperature 40 to 122F
(4 to 50C)
Humidity

5%-95% relative
humidity, non
condensing

5%-95% relative
humidity, non
condensing

5%-95% relative
humidity, non
condensing

5%-95% relative
humidity, non
condensing

Max Heat
Dissipation
fully
loaded

CX / CXi 170 BTUs per hour


MXe 750 BTUs per hour
MXe Server 1000 BTUs
per hour
AX 1024 BTUs per hour

ASU 170 BTUs per hour


ASU II 260 BTUs per hour

60 BTUs per hour

724 BTUs per hour

Air Flow

46 cubic ft/min at maximum


output of fans
AX 110 cubic ft

150 cubic ft/min at


maximu output
of fans

Acoustic
Emissions

Max 50dBA continuous, 75dBA


intermittent (<10% duty cycle)

Max 50dBA continuous,


75dBA intermittent
(<10% duty cycle)

Conversion factors: One watt is equal to 3.412 BTUs per hour. One ton of refrigeration is equal to 12,000 BTUs per hour or 3.516 Kilowatts, and 0.75 kilowatt-hour is equal to
one ton of refrigeration.

6 MITEL DATA SHEET 3300 IP COMMUNICATIONS PLATFORM

System Input Power Requirements


3300 Controller

Analog Services
Unit (ASU and ASU II)

Network Services
Use (NSU)

Peripheral Cabinet

Input/
Disconnect

IEC320-C14 Class 1 AC
Receptacle
2 Receptacles on AX and
MXe / MXe Server with
redundant power

IEC320-C14 Class 1 AC
Receptacle

IEC320-C14 Class 1 AC
Receptacle

IEC320-C14 Class 1 AC
Receptacle

Input
Voltage /
Frequency
Rating

100-240 VAC
50 / 60 Hz

100-240 VAC
50 / 60 Hz

100-240 VAC
50 / 60 Hz

102-120 VAC
50 / 60 Hz MP914AA
PSU Variant200-240
VAC
50/60 Hz MP914AD
PSU Variant

ASU 75 W max
ASU II 125 W max

Universal NSU 20 W
R2 NSU 30 W

200 W typical
(ONS and DNI Mix)
300 W typical (all DNI)
540 W Max (input
surge, all DNI)

Input Power CX / CXi 250 W


MXe 200 W
MXe Expanded 250 W
MXe Server 300 W
AX 300 W
AC Source

90-264 VAC

90-264 VAC

90-264 VAC

102-132 VAC

Range

47-63 Hz

67-63 Hz

67-63 Hz

47-63 Hz MP914AA
187-264 Hz MP914AD

IP COMMUNICATIONS PLATFORM MITEL DATA SHEET 7

Glossary
ACD

Automatic Call Distribution

ISDN

Integrated Services Digital Network

ASU

Analog Services Unit

LS

Loop Start Trunk

BRI

Basic Rate Interface

MMC

MITEL Mezzanine Card

BTU

British Thermal Unit

MOH

Music on Hold

CAS

Channel Associated Signaling

MSDN

Mitel Superswitch Digital Network

CCS

Common Channel Signaling

NFAS

Non-Facilities Associated Signaling

CIM

Copper Interface Module

NSU

Network Services Unit

CLASS

Custom Local Access Signaling Services

OPS

Off Premises, long loop analog PBX ports

DASSII

Digital Access Signaling System #2

PRI

Primary Rate Interface, ISDN

DID/DDI Direct Inward Dial / Direct Dial In

QSIG

Q Signaling Protocol

DNI

Digital Network Interface

RSTP

Rapid Spanning Tree Protocol

DPNSS

Digital Private Network Signaling System

SIP

Session Initiation Protocol

DSP

Digital Signal Processor

STP

Spanning Tree Protocol

DTMF

Dual Tone Multi-Frequency

VM

Voice Mail

FIM

Fiber Interface Module

XNET

Switched Networking

IP

Internet Protocol

www.mitel.com

Global Headquarters

U.S.

EMEA

CALA

Asia Pacific

Tel: +1(613) 592-2122


Fax: +1(613) 592-4784

Tel: +1(480) 961-9000


Fax: +1(480) 961-1370

Tel: +44(0)1291-430000
Fax: +44(0)1291-430400

Tel: +1(613) 592-2122


Fax: +1(613) 592-7825

Tel: +852 2508 9780


Fax: +852 2508 9232

For more information on our worldwide office locations, visit our website at www.mitel.com/offices
THIS DOCUMENT IS PROVIDED TO YOU FOR INFORMATIONAL PURPOSES ONLY. The information furnished in this document, believed by Mitel to be accurate as of the date
of its publication, is subject to change without notice. Mitel assumes no responsibility for any errors or omissions in this document and shall have no obligation to you as a
result of having made this document available to you or based upon the information it contains.
M MITEL (design) is a registered trademark of Mitel Networks Corporation. All other products and services are the registered trademarks of their respective holders.
Copyright 2008, Mitel Networks Corporation. All Rights Reserved.

GD 392_891 PN 51008713RI-EN

You might also like