Battery Specs
Battery Specs
Battery Specs
Cat Premium High Output (PHO) batteries are used in all Caterpillar
Maintenance Free or low maintenance designs are available in wet and dry
configurations.
equipment investments.
Cold
Cranking
Amps
1500
Reserve
Capacity
Minutes
465
Part No.
153-5720
8D
101-4000
1400
400
12
190
LAC+
1000
4D
153-5710
1400
425
12
200
MF
4D
153-5700
1125
305
12
145
MF
4D
9X-9730
1300
400
12
190
LAC+
Volts
12
Amp Hr.
Capacity
@ 20 Hrs.
210
Construction
C
Add Water
Maintenance
Check Hours
MF
Height
In (mm)
9.76 (248)
Wet
Lb (kg)
132 (60)
Dry
Lb (kg)
Nominal
Acid to Fill
Qt (liter)
20.7 (526.5)
10.96 (278)
9.76 (248)
132 (60)
86 (39)
18.0 (17.0)
20.47 (520)
8.58 (218)
9.76 (248)
119 (54)
20.47 (520)
8.58 (218)
9.76 (248)
101 (46)
1000
20.75 (527)
8.58 (218)
9.76 (248)
119 (54)
81 (37)
14.8 (14.0)
15.9 (15.0)
Length
In (mm)
20.47 (520)
4D
9X-9720
1000
275
12
140
LAC+
1000
20.75 (527)
8.58 (218)
9.76 (248)
101 (46)
59 (27)
31
175-4390
1000
180
12
90
C/S
MFA
12.9 (328.4)
6.74 (171.2)
9.29 (236)
60 (27)
31
175-4370
825
190
12
100
C/S**
MFA
12.9 (328.4)
6.74 (171.2)
9.29 (236)
60 (27)
31
175-4360
710
185
12
100
C/S***
MFA
12.9 (328.4)
6.74 (171.2)
9.29 (236)
60 (27)
31
250-0480
710
185
12
100
C/SDT***
MF
12.9 (328.4)
6.74 (171.2)
9.29 (236)
60 (27)
31
115-2422
1000
170
12
90
C SAE
MFA
12.9 (328.4)
6.74 (171.2)
9.46 (240.3)
60 (27)
31
115-2421
950
170
12
90
C SAE +
MFA
12.9 (328.4)
6.74 (171.2)
9.46 (240.3)
60 (27)
44 (20)
6.6 (6.2)
31
9X-3404
950
165
12
100
C SAE
MF
13 (330.2)
6.77 (172)
9.46 (240.3)
58 (26)
31
3T-5760
750
165
12
100
C SAE
MF
13 (330.2)
6.77 (172)
9.46 (240.3)
55 (25)
24
153-5656
650
110
12
52
SC
MF
10.98 (278.9)
6.85 (174)
9.0 (229.1)
39 (18)
65
230-6368
880
140
12
80
SC
MF
11.9 (303.4)
7.5 (190.8)
7.5 (191.4)
45.5 (21)
74
153-5660
650
110
12
52
SC*
MF
10.98 (278.9)
7.0 (178.2)
8.15 (206.9)
39 (18)
58
175-4280
500
70
12
35
SC
MF
9.96 (253.1)
7.2 (182.5)
6.9 (176)
31 (14)
153-5690
765
210
90
LAC+
1000
10.24 (260)
6.8 (173)
8.72 (221.6)
37 (17)
22 (10)
4.8 (4.5)
Construction Notes:
LAC = Low Maintenance, Hybrid Construction
C = Calcium Lead Alloy Grid Design
MF = Maintenance Free
MFA = Maintenance Free with Accessible Vent Caps
S = Stud Terminals
+ = Shipped Dry Only
* = Side Terminals
** = Starting and Deep Cycle Battery
*** = Deep Cycle and Starting Battery
" = For 30 seconds at 0 F (-18 C)
' = Minimum of 25 amp output at 80 F (27 C)
SAE = Uses SAE Posts
SDT = Dual, Top mounted Terminals, Stud and SAE Post,
Marine Deep Cycle/Starting Battery
SC = Silver (Ag) Calcium Alloy Grids for resistance to high
underhood temperatures
Wet Batteries
BCI
Group
Size
Part No.
Nominal Weight
Reserve
Capacity
Minutes
Volts
Amp Hr.
Capacity
@ 20 Hrs.
Construction
Length
In (mm)
Width
In (mm)
Height
In (mm)
Wet
Lb (kg)
Truck/Agricultural/Industrial
1
8C-3617
650
180
100
C/MF
9.0 (229)
6.9 (175)
8.8 (224)
33.5 (15)
8C-3629
780
215
90
LA
10.4 (264)
6.9 (175)
8.8 (224)
36.5 (17)
3EE
8C-3620
400
95
12
54
LA
19.3 (490)
4.3 (109)
9.0 (229)
43 (20)
3EH
8C-3632
925
250
115
LA
19.3 (490)
4.3 (109)
10.0 (254)
47.5 (22)
8C-3633
1010
270
125
C/MF
12.5 (318)
6.9 (175)
9.5 (241)
47 (21)
4D
8C-3623
900
260
12
115
LA
20.8 (508)
8.5 (216)
10.1 (257)
97 (44)
4DLT
8C-3622
900
240
12
100
LA
20.0 (508)
8.2 (208)
8.2 (208)
79 (36)
7D
8C-3635
950
350
156
LA
15.8 (401)
7.0 (178)
9.2 (234)
59.5 (27)
8D
8C-3624
1375
430
12
190
LA
20.7 (526)
11.0 (279)
10.0 (254)
130 (59)
24F
3T-5858
650
120
12
55
SC/MF
10.6 (269)
6.8 (173)
9.0 (229)
40 (18)
27
8C-3601
675
120
12
65
SC/MF
12.0 (305)
6.7 (170)
9.0 (229)
45.5 (21)
27F
8C-3602
675
120
12
65
SC/MF
12.4 (315)
6.7 (170)
9.0 (229)
45.5 (21)
30H
8C-3627
850
180
12
100
C/MF
13.0 (330)
6.8 (173)
9.5 (241)
57.5 (26)
31
8C-3628
760
170
12
80
C/MF/S
13.0 (330)
6.8 (173)
9.5 (241)
54.5 (25)
450
12
190
C/MFA/TB
20.7 (526)
11.0 (279)
10.0 (254)
134 (61)
Bus-Special Terminal
8D
250-0473
1450
3T-5859
425
65
12
35
SC/MF
9.4 (239)
6.8 (173)
8.3 (211)
29.5 (13)
24
3T-5857
650
120
12
55
SC/MF
10.2 (259)
6.8 (173)
9.0 (229)
38.5 (17)
26
8C-3600
540
80
12
45
SC/MF
8.8 (224)
6.8 (173)
8.0 (203)
24.5 (11)
41
8C-3605
660
110
12
64
SC/MF
11.5 (292)
6.9 (175)
6.9 (175)
37 (17)
42
250-0490
475
70
12
40
SC/MF
9.5 (241)
6.9 (175)
6.9 (175)
29 (13)
55/56/62
8C-3611
585
95
12
52
SC/MF/DT
8.8 (224)
6.0 (152)
8.5 (216)
33 (15)
58
8C-3612
580
85
12
53
SC/MF
10.0 (254)
7.2 (183)
6.9 (175)
31.5 (14)
75
7X-6100
720
100
12
60
SC/MF *
9.0 (229)
7.0 (178)
7.3 (185)
34.5 (16)
75/86
250-0489
540
85
12
47
SC/MF/DT
9.7 (248)
7 (178)
8.1 (206) !
32 (15)
31 (14)
Automotive/Light Truck & SUV, Severe Service/High Temperature, Silver Lead Alloy Technology
25
250-0488
600
90
12
45
ST/MF
9.1 (230)
6.8 (175)
8.8 (225)
35
250-0487
600
90
12
45
ST/MF
9.1 (230)
6.8 (175)
8.8 (225)
31 (14)
34/78
250-0486
690
100
12
60
ST/MF/DT
10.7 (273)
6.8 (175)
8 (203) !
39 (18)
65
250-0484
650
105
12
55
ST/MF
12 (304)
7.3 (187)
7.6 (194)
39 (18)
Construction Notes:
LA = Low Maintenance, Low Antimony Grids
LAC = Low Maintenance, Hybrid Construction
C = Calcium Lead Alloy Grid Design
MF = Maintenance Free
* = Side Terminals
S = Stud Terminals
DT = Dual Terminal
TB = Transit Bus one piece end Terminal.
Right end of Battery.
1/2"-13 Steel positive stud
3/8"-16 Steel negative stud
Continued
BCI
Group
Size
Cold
Cranking
Amps
Part No.
Reserve
Capacity
Minutes
Volts
Amp Hr.
Capacity
@ 20 Hrs.
Construction
Length
In (mm)
Height
In (mm)
Nominal Weight
Wet
Lb (kg)
8C-3638
650
120
12
55
SC/MF/DT/~
10.8 (274)
6.8 (173)
9.4 (239)
40 (18)
27M
8C-3639
625
150
12
80
@ /S/DT
12.5 (318)
6.8 (173)
9.4 (239)
49 (22)
275
32
12
25
C/MF
7.8 (198)
5.1 (130)
7.3 (185)
16.5 (7)
215
@ OP
10.3 (262)
7.1 (180)
10.9 (277)
63 (29)
8C-3636
75 amps
@ 80 F
115 mins.
8C-3641
127-0824
930
130
12
63
SC/MF/DT
10.9 (277)
7.0 (178)
9.0 (229)
45 (20)
34/78
127-0826
875
120
12
66
SC/MF/DT
10.8 (274)
6.9 (175)
8.0 (203) !
41 (19)
75/86
250-0489
540
85
12
47
SC/MF/DT
9.7 (248)
7 (178)
8.1 (206) !
32 (15)
34/78
250-0486
690
110
12
60
ST/MF/DT
10.7 (273)
6.8 (175)
8 (203) !
39 (18)
Dry Batteries
BCI
Group
Size
Part No.
Cold
Cranking
Amps
Nominal Weight
Volts
Amp Hr.
Capacity
@ 20 Hrs.
Length
Construction In (mm)
Width
In (mm)
Height
In (mm)
Wet
Lb (kg)
Dry
Lb (kg)
Nominal
Acid to Fill
Qt (liter)
4.5 (4.3)
Truck/Agricultural/Industrial
1
8T-9734
650
180
100
C/MF +
9.0 (229)
6.9 (175)
8.8 (224)
33.5 (15)
17.5 (8)
3D
8T-9730
1400
675
320
LA +
20.4 (518)
8.7 (221)
10.0 (254)
120 (54)
84 (38)
11.0 (10.4)
7D
8T-9731
950
350
156
LA +
15.7 (399)
7.0 (178)
9.1 (231)
59.5 (27)
34 (15)
7.5 (7.1)
24F
9X-1382
650
120
12
50
SC/MF +
10.6 (269)
6.8 (173)
9.0 (229)
40 (18)
26 (12)
6.0 (5.7
26
145-4517
540
80
12
48
SC/MF +
8.8 (224)
6.8 (173)
8.0 (203)
29.5 (13)
23 (10)
3.5 (3.3)
26R
145-4518
540
80
12
48
SC/MF +
8.8 (224)
6.8 (173)
8.0 (203)
29.5 (13)
23 (10)
3.5 (3.3)
27
3E-8925
675
120
12
55
SC/MF +
12.0 (305)
6.7 (170)
9.0 (229)
45.5 (21)
29.5 (13)
6.5 (6.2)
Automotive/Light Truck
22F
9X-1384
425
65
12
32
SC/MF +
9.4 (239)
6.8 (173)
8.3 (211)
29.5 (13)
18 (8)
4.5 (4.3)
24
9X-1383
650
120
12
50
SC/MF +
10.2 (259)
6.8 (173)
9.0 (229)
40 (18)
26 (12)
6.0 (5.7)
350
175
LA +
20.8 (528)
7.3 (185)
10.6 (269)
90 (41)
60 (27)
11.5 (10.9)
Marine/Recreational
8V
8C-3640
980
DT = Dual Terminal
OP = Offset Post with Horizontal Hole Stainless Steel 5/16"
Bolt & Hex Nut
" = For 30 seconds at 0 F (-18 C)
' = Minimum of 25 amp output at 80 F (27 C)
! For height with removable adapter, add 7/8" (22 mm)
@ = Deep Cycle Antimony Grids
~ = Marine Starting
+ = Shipped Dry Only
# = Wing Nut for 8C-3638 & 8C-3639 is Part # 3B-0723
Construction Notes:
LA = Low Maintenance, Low Antimony Grids
LAC = Low Maintenance, Hybrid Construction
C = Calcium Lead Alloy Grid Design
MF = Maintenance Free
MFA = Maintenance Free, Calcium Grids, Accessible Vent Caps
ST = Silver (Ag) Calcium Alloy Heavy Duty Grids
SC = Silver (Ag) Calcium Alloy Grids for resistance to high
underhood temperatures
* = Side Terminals
S = Stud Terminals
Part No.
Cold
Cranking
Amps
Reserve
Capacity
Minutes
152-8006
152-7242
1050
1265
375
475
Volts
Amp Hr.
Capacity
@ 20 Hrs.
12
12
183
225
Construction
Length
In (mm)
Width
In (mm)
Height
In (mm)
Wet
Lb (kg)
MF-G/VRLA
MF-G/VRLA
20.8 (528)
20.8 (528)
8.5 (216)
11.1 (282)
10 (254)
10 (254)
129.8 (59)
160.8 (73)
Absorbed Glass Mat (AGM) Batteries, Designed for High-rate Uninterruptible Power Supplies (UPS) or Standby Applications
Discharge Ratings
Power
Watts
per Cell
Discharge
Rating in
Amperes
BCI
Group
Size
Part No.
For 15 mins.
to 1.67 V.P.C.
@ 77 F
(25 C)
For 15 mins.
to end voltage
of 1.75 V.P.C.
@ 77 F
(25 C)
U1
250-0474
119
60
45
250-0475
168
85.4
24
250-0476
253
127
27
250-0477
314
31
250-0478
31(A)
4D(H)
Amp Hour @
20 hour rate
to 1.75 volts
per cell @
77 F (25 C)
Nominal Weight
Length
In (mm)
Width
In (mm)
Terminal
Height
In (mm)
7.71 (196)
5.18 (132)
7.18 (182)
6.18 (157)
24 (11)
8.84 (225)
5.31 (135)
8.7 (221)
8.14 (207)
38.5 (18)
MF-AGM/VRLA
10.2 (259)
6.8 (173)
9.14 (232)
8.12 (206)
53 (24)
12
MF-AGM/VRLA
8.68 (220)
8.12 (206)
63 (29)
4.68
12
MF-AGM/VRLA
8.75 (222)
8.58 (218)
69 (31)
238
6.66
12
MF-AGM/VRLA
13.5 (342)
98 (45)
318
9.91
12
MF-AGM/VRLA
9.34 (237)
129 (59)
Normal
Voltage
Construction
1.46
12
MF-AGM/VRLA
2.42
12
MF-AGM/VRLA
3.65
12
156
4.41
377
192
250-0479
475
250-0483
624
Terminal
6.77 (172)
Container
Height
In (mm)
Wet
Lb (kg)
8.74 (222)
MF-AGM/VRLA = Maintenance Free-Absorbed Glass Mat (AGM) Battery. Battery has Flame Arrestor and is low-pressure self sealing.
Housed in flame-retardant polypropylene (rated 28 LOI) 12-Volt Monoblocks
(A) = Battery is 2.5 in (63.5 mm) taller and 0.57 in (13 mm) longer than standard Group 31
(H) = Battery has handles
Sealed Valve-Regulated Lead Acid (VRLA) with electrolyte absorbed in separators consisting of a sponge-like mass of matted glass fibers.
Preferred for high-rate performance in uninterruptible power supply (UPS) or standby applications.
VPC = Volts per Cell
WPC = Watts per Cell. Ratings conform to IEEE-485 Standards
VRLA batteries use recombination reaction to prevent the escape of hydrogen and oxygen gases normally lost in a flooded lead
acid battery. They are non-spillable, never need watering and should never be opened.
UL Recognized Component
AGM batteries have a longer production lead time than regular lead-acid type batteries
Important: Alternator and charger instructions: for 12-volt AGM Batteries charge to 14.4 volts but no more than 14.6 volts at 68 F (20 C)
3-BCI Group 31
Terminals
Battery Information
Cat Premium High Output Batteries Built Tough to Exceed
Demanding Performance Test Requirements:
GP 2E
3 EH
4EH
Battery must pass a high rate discharge test after the vibration testing
Five 72-hour Deep Discharge/Recharge Test Cycles
GP 4DLT
GP 31
28
6-Volt
GP 1,2,3,4
5D, 7D, GC2,
GC2H, 3D,
17 HF, 19L
Side Terminal
GP70, 71, 72, 73, 74
75, 76, 77, 78, 101
Battery Accessories
Group 31 Charging Posts for Stud Terminals Part # 4C-5637
Screw-in Charging Posts for Side Terminals Part # 4C-5638
Wing Nut Part # 2B-9498 for Part #s 175-4390/175-4370/175-4360/8C-3628
Wing Nut Part # 3B-0723 for Part #s 8C-3638 and 8C-3639
Digital Battery Analyzer Part # 177-2330
Battery Voltmeter Part # 4C-6600
Battery Load Tester Part # 4C-4911
Booster Cable 12' (3.66 m) Part # 4C-4933
Booster Cable 20' (6.00 m) Part # 4C-4937
Heavy Duty Commercial Fast Charger (110V) Part # 4C-4921
Heavy Duty Commercial Fast Charger (220V) Part # 4C-4910
Extra Vent Caps (6) for Dry Batteries Part # 7N-0060
Note: Ratings and Part Numbers are subject to change without notice.
Recycle all scrap batteries.
We accept lead-acid batteries
for recycling.
Cat Batteries
World Wide Application Flexibility
Marine Commercial Vessels
Maintenance Free 4D, 8D and Group
31 Batteries. General Service Line
Line valve regulated (VRLA) Gel
batteries. High Marine Cranking
Amps (MCA) and Deep Cycling
capabilities.
Automotive-Truck-Bus & RV
A wide selection of popular BCI group
sizes. Maintenance Free, Severe Service
and Deep Cycle models. Application
Specific Group 31 Truck Batteries.
Cat Batteries
Heavy-duty Forged Terminal Post Bushings
Built-in Flame
Arrestor
Robust
Reinforced
Case
Vibration
Resistant
Plates &
Elements
Rugged
Separators
Heavy-duty Grids
Robust Components = Long Life + Reliable Starts
Heavy-duty forged terminal post bushings provide maximum strength and resistance to acid seepage that causes corrosion
and black posts. Thicker internal terminal posts provide lower electrical resistance and higher cold cranking amp output.
Rugged microporous polyethylene envelope separators protect against shorts and vibration damage. Deep Cycle
batteries utilize double insulated Glass mat separators for longer cycling life.
Maintenance Free batteries utilize calcium lead alloy on both positive and negative plates that reduces gassing and water
consumption. Automotive batteries have Silver (Ag) Calcium Alloy Grids for resistance to high underhood temperatures.
Heavy-duty, full frame battery grids with no sharp edges. An optimum acid/paste combination provides better charge
acceptance after a deep discharge.
Positive and Negative plates are anchored to the container bottom and the cell element is locked at the top for maximum
vibration resistance. Straps are thicker, heavier and cast (not welded) into the plates.
Manifold vented cover with built-in Flame Arrestora safety feature that directs corrosive gases away from the battery
and hold-downs.
Robust reinforced case provides extra strength in all temperature extremes. Brickwork design on sides reduces chance of
punctures and case flexing. Embossed part number and descriptors for easy serviceability.
CAT, CATERPILLAR, their respective logos and Caterpillar Yellow, as well as corporate and product identity
used herein, are trademarks of Caterpillar and may not be used without permission.
PEHJ0073-01
2005 Caterpillar