0% found this document useful (0 votes)
436 views2 pages

Tema Sheet

This document provides a heat exchanger rating report for a horizontal shell and tube heat exchanger with multipass flow and single-segmental baffles. The summary includes: - Process conditions for the cold water and hot steam streams including flow rates, temperatures, pressures and fouling factors. - Exchanger performance metrics such as heat transfer coefficients, temperature profiles, duty, effectiveness and design parameters. - Geometry details of the shell, tubes, baffles and nozzles. - Thermal resistances breakdown and flow velocities in the exchanger.

Uploaded by

Murad ALi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
436 views2 pages

Tema Sheet

This document provides a heat exchanger rating report for a horizontal shell and tube heat exchanger with multipass flow and single-segmental baffles. The summary includes: - Process conditions for the cold water and hot steam streams including flow rates, temperatures, pressures and fouling factors. - Exchanger performance metrics such as heat transfer coefficients, temperature profiles, duty, effectiveness and design parameters. - Geometry details of the shell, tubes, baffles and nozzles. - Thermal resistances breakdown and flow velocities in the exchanger.

Uploaded by

Murad ALi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Output Summary

Page 1

Released to the following HTRI Member Company:


Microsoft
ICT
Xist 7.2.1 6/15/2015 13:16 SN: 01101-1199875904

SI Units

Rating - Horizontal Multipass Flow TEMA BEU Shell With Single-Segmental Baffles
See Data Check Messages Report for Warning Messages.
See Runtime Message Report for Warning Messages.
Process Conditions
Fluid name
Flow rate
Inlet/Outlet Y
Inlet/Outlet T
Inlet P/Avg
dP/Allow.
Fouling

Cold Shellside

(kg/s)
(Wt. frac vap.)
(Deg C)
(kPa)
(kPa)
(m2-K/W)

0.0000
130.99
291.32
2.711

Hot Tubeside

WATER IN
3.9356
0.2990
132.17
289.97
5.000
0.000260

1.0000
148.00
451.32
2.764

STEAM IN
1.2092
0.0000
147.59
449.94
5.000
0.000100

Exchanger Performance
Shell h
Tube h
Hot regime
Cold regime
EMTD

(W/m2-K)
(W/m2-K)
(--)
(--)
(Deg C)

4415.0
21442
Transition
Flow
15.5

Actual U
Required U
Duty
Eff. area
Overdesign

Shell Geometry
TEMA type
Shell ID
Series
Parallel
Orientation

BEU
750.00
1
1
0.00

(--)
(mm)
(--)
(--)
(deg)

Baffle type
Baffle cut
Baffle orientation
Central spacing
Crosspasses

27.79
7.35
47.67
17.19

(Pct Dia.)
(--)
(mm)
(--)

Single-Seg.
46.61
Parallel
317.00
15

Nozzles

(--)
(mm)
(m)
(--)
(deg)
(--)
(--)

Thermal Resistance, %
Shell
Tube
Fouling
Metal

1227.1
1062.2
2.5957
158.03
15.53

Baffle Geometry

Tube Geometry
Tube type
Tube OD
Length
Pitch ratio
Layout
Tubecount
Tube Pass

(W/m2-K)
(W/m2-K)
(MegaWatts)
(m2)
(%)

Plain
19.050
5.000
1.3333
90
532
2

Shell inlet
Shell outlet
Inlet height
Outlet height
Tube inlet
Tube outlet

(mm)
(mm)
(mm)
(mm)
(mm)
(mm)

Velocities, m/s
Tubeside
Crossflow
Window

Min
9.10e-2
0.25
8.76e-2

101.60
254.00
33.860
46.550
152.40
50.800

Flow Fractions
Max
10.63
9.71
5.91

A
B
C
E
F

C:\Users\ali.murad\Desktop\E-2311 Rev-5.htri

0.045
0.668
0.041
0.049
0.197

HEAT EXCHANGER SPECIFICATION SHEET

Customer
Address
Plant Location
Service of Unit
Size
Surf/Unit (Gross/Eff)

750 x 5000
mm
Type
BEU
Horizontal
159.19 / 158.03 m2
Shell/Unit
1
PERFORMANCE OF ONE UNIT
Shell Side
WATER IN
kg/hr
14168
4236.5
14168
9931.5

Page 2
SI Units

Job No.
Reference No.
Proposal No.
Date
6/15/2015
Rev
Item No.
Connected In
1
Parallel
1 Series
Surf/Shell (Gross/Eff)
159.19 / 158.03 m2

Fluid Allocation
Tube Side
Fluid Name
STEAM IN
Fluid Quantity, Total
4353.0
Vapor (In/Out)
4353.0
Liquid
4353.0
Steam
Water
Noncondensables
Temperature (In/Out)
C
130.99
132.17
148.00
147.59
Specific Gravity
0.9215
0.9204
0.9064
Viscosity
mN-s/m2
0.2093
0.0132 V/L 0.2073
0.0138
0.1842
Molecular Weight, Vapor
Molecular Weight, Noncondensables
Specific Heat
kJ/kg-C
4.4914
1.9441 V/L 4.4959
1.9694
4.5598
Thermal Conductivity
W/m-C
0.6878
0.0271 V/L 0.6879
0.0284
0.6870
Latent Heat
kJ/kg
2187.4
2188.3
2141.7
2142.7
Inlet Pressure
kPa
291.32
451.32
Velocity
m/s
5.28
5.39
Pressure Drop, Allow/Calc kPa
5.000
2.711
5.000
2.764
Fouling Resistance (min)
m2-K/W
0.000260
0.000100
Heat Exchanged
2595673 W
MTD (Corrected)
15.5
C
Transfer Rate, Service
1062.2 W/m2-K
Clean 2344.9
W/m2-K
Actual 1227.1 W/m2-K
CONSTRUCTION OF ONE SHELL
Sketch (Bundle/Nozzle Orientation)
Shell Side
Tube Side
Design/Test Pressure
kPaG
517.11
/
517.11 /
Design Temperature
C
160.00
176.67
No Passes per Shell
1
2
Corrosion Allowance
mm
3.175
3.175
Connections
In
mm
1 @ 101.60
1 @ 152.40
Size &
Out
mm
1 @ 254.00
1 @ 50.800
Rating
Intermediate
@
@
Tube No. 266U
OD 19.050 mm
Thk(Avg) 2.110 mm
Length 5.000 m
Pitch 25.400 mm
Tube Type Plain
Material 304 Stainless steel (18 Cr, 8 Ni)
Tube pattern 90
Shell
Carbon steel
ID 750.00
OD 772.23 mm
Shell Cover
(Integ.)
Channel or Bonnet
Channel Cover
Tubesheet-Stationary
Tubesheet-Floating
Floating Head Cover
Impingement Plate Rectangular plate
Baffles-Cross
Type Single-Seg.
%Cut (Diam) 46.61 Spacing(c/c) 317.00
Inlet 317.00 mm
Baffles-Long
Seal Type None
Supports-Tube
U-Bend
Type Full support
Bypass Seal Arrangement 1
pairs seal strips
Tube-Tubesheet Joint
Expanded (No groove)
Expansion Joint
Type
Rho-V2-Inlet Nozzle 255.84 kg/m-s2
Bundle Entrance
16.01
Bundle Exit
923.35 kg/m-s2
Gaskets-Shell Side
Tube Side
-Floating Head
Code Requirements
TEMA Class R
Weight/Shell
4310.6
kg
Filled with Water
6594.3
kg
Bundle 2904.9
kg
Remarks:

Reprinted with Permission (v7.20 .1)

C:\Users\ali.murad\Desktop\E-2311 Rev-5.htri