The demand for improved and excellent water quality has been a fundamental need since time immemorial and is also a
prediction for optimal results in various aspects of world and life. The technological and legal requirements for an optimal
water treatment are constantly rising.
In most of the industrial processes water is an essential raw material. Particular in the Food & Beverage Industry most of
the production activities require good water quality. As the microbiological contamination of the process water is a critical
issue a reliable and optimal control of all biological parameter is indispensable.
All of the classical ECA devices offered in the market are using a brine solution (NaCl) in order to produce a disinfectant
material via cathodic and anodic reactions. In such electrolysis only 20 % max. of the brine solution are going to be
converted into a disinfectant (HOCl).
The significant downside and threats whilst operating such devices are obviously high corrosion risks, because of the
carryover of chlorides. This effect is relevant to all commercial offered devices. Due to the material used, particular in the
Food & Beverage Industry such a disinfectant was not applicable for the industry because of the risks.
Pure
NaOH
0,05 5,00 %
H2
Saturated
Brine
HOCl
minimum salt
impurities
anolyte
catholyte
HOCl
H2
O2
Na+
OH
Cl
Saturated
Brine
H 2O
anode reaction:
cathode reaction:
2Cl + H2O
+
CATHODE
The electrochemical activation technology (ECA) is the generation of activated solutions (Anolyte & Catolyte) whilst
using a diluted salt solution (sodium chloride NaCl). This
electrolysis process is an applicable alternative in the area
of disinfection to the dosage of conventional chemicals
in case the technology is able to produce a disinfectant
without critical by-products.
Based on its well known core competence in electrochemical technologies FumaTech in cooperation with the BWT
R&D department has developed an advanced electrolysis
process for producing an effective and reliable disinfectant
on demand.
ANODE
In many operation the water quality is currently controlled whilst using halogen-based chemical disinfectants and
cleaning agents. Those chemicals used (Chlorine and its
chemical compounds) are acting as effective disinfectants
in order to ensure the microbiological quality of the water.
There are some remarkable disadvantages with operating
chemicals such as the handling (e.g Chlorine Gas) and the
environmental impact.
2Na + 2 H2O + 2e
H2O
HOCl + H+ + 2e
2 NaOH + H2
|5
Effective Disinfection
softened water *
Active specie
Mechanism
Disinfectant
Purities
* Due to the unique design and stand-alone FumaTech technology, there will be
no transfer of salt solutions into the anolyte compartment.
concentraion
(mg/l)
fumaGen is a patented electrolysis technology manufactured by BWT. As various unit capacities are available it is
ensured that the amount of on-site produced disinfectants is equivalent to the individual plant requirements.
200,00
150,00
100,00
50,00
-
anolyte 1
anolyte 2
anolyte 3
200
160
300
180
400
200
500
g/h
30
48
72
96
mg/l
150
170
190
210
Chlorate
mg/l
< 3.5
< 3.5
< 3.5
< 3.5
Chlorite
mg/l
< 0.3
< 0.3
< 0.3
< 0.3
> 1000
> 1000
> 1000
> 1000
14
13
12
11
mV
KWh/kg
ph value
5.5
5.5
5.5
5.5
g/h
90
143
215
260
kg/24h
2.2
3.2
5.2
6.2
Salt consumption
NaCl consumption
daily salt consumption
40.000,00
Bacillus subtilis
(Sp./ml)
l/h
150
30.000,00
2,00
-
anolyte 1
anolyte 2
anolyte 3
anolyte 4
TVO
permitted
summery
anolyte 2
10.000,00
anolyte 1
0 min.
>
>
>
<
180
1000
log4
2
1:1
3,6
ppm
mV
weeks
mg/l
10 min.
1.000,00
800,00
600,00
400,00
200,00
-
source:
anolyte 3
20.000,00
ORP
mg/l
ORP
4,00
killing ratio of more than log 4 proven for different anolyte solutions
6,00
Number of cells
8,00
anolyte 4
degradation of FAC during disinfection and persistence of FAC for deposit effect
20,00
anolyte 2
anolyte 3
FAC
fumaGen LS series
Chloride (mg/l)
FAC (ppm)
Chlorate (mg/l)
10,00
250,00
15,00
10,00
5,00
-
anolyte 2
anolyte 3
|7
Safety features:
Catalytic hydrogen destruction plus hydrogen sensor in the
cabinet
Dilute 1:20
CIP Tank
10ppm FAC
Buffer Tank
Buffer Tank
Catholyte
Concentrate
Anolyte
Concentrate
Step 2
Step 3
|9
Return on Investment
Replacement of the traditional used chemicals and reduction of operational cost
As the generator is not producing any critcal by-products (such as chlorate) and the corrosion potential is extremely low
the advantage is having a reliable and strong disinfectant available at any time. This results in significant reduction of
water and hot water usage.
Energy saving and increased production availability are generating significant higher profitability.
Druck: 140331DK
FuMA-Tech Gesellschaft fr
funktionelle Membranen und
Anlagentechnologie mbH
Carl-Benz-Strae 4
D-74321 Bietigheim-Bissingen
Tel.: +49/7142/3737-900
Fax: +49/7142/3737-999
E-Mail: [email protected]
www.fumatech.de
BWT Aktiengesellschaft
Walter-Simmer-Strae 4
A-5310 Mondsee
Tel.: +43/6232/5011-0
Fax: +43/6232/4058
E-Mail: [email protected]
www.bwt-group.com
BWT For You and Planet Blue signifies our mission to take ecological,
economic and social responsibility,
and to provide our customers with
the best products, systems, technologies and services in all areas of
water treatment, while making a
valuable contribution to the preservation of our blue planets global
resources.