Clamp-on Power Meter
A Simple Yet A Powerful Power
Measuring Tool.
Features
AC / DC Power up to 600 kW
True RMS for AC .
Harmonics 1st to 25th order
Power fluctuation using the ACA Inrush and
Peak hold functions.
AC / DC Voltage max. 1000 V
AC / DC Current max. 600 A
Frequency, Resistance, Continuity, Diode check,
Power factor.
Up to 9999 counts, approx. 37mm max.
diameter of measurable conductor (the jaw
opens approx. 45mm max.)
For Safety
CATIV 600V and CATIII 1000V compliant.
Useful Functions
Backlight on the display area turns on and a
white LED automatically illuminates the front of
jaw when clamping.
Non-contact Voltage Detection (Red LED lights
up on detection).
Easy Operation with the Navigator key.
Low Pass Filter, Phase Detection, AC / DC
Auto Sense.
LOAD
Motor power measurement application
LF CW10-EN
LFCW10-EN_010.indd 1
7/15/11 9:28:21 AM
Application
Explanation
Inrush Current Measurement Method
Figure 1 Small motor
Inrush current
A function to measure inrush current is available.
This function allows you to easily measure inrush current
that occurs when starting a motor, relay, or the like.
Just clamp the CW10 to the motor and set INRUSH
before starting the motor to automatically measure
and hold the inrush current that occured in 100 ms
period (Figure 2).
Figure 2
What is inrush current?
Inrush AC current
Displays RMS value of 100ms period.
Starting current or inrush current is the
instantaneous electrical current that flows when
the power is initially turned on.
Specifications
Accuracy
Active Power
23 5C, 80%RH or less
Accuracy: (% of reading + digits)
Function
Voltage
Rms-value detection
Function
DCV
ACV
LPF
ACV
Range
Resolution
(Maximum reading)
100 V
99.99 V
1000 V
999.9 V
100 V
99.99 V
1000 V
999.9 V
100 V
99.99 V
1000 V
999.9 V
* DCV<1000digits: add 6digits to accuracy
ACV<1000digits: add 3digits to accuracy
Maximum input voltage: 1000 Vrms, 1414.2 Vpk
Input impedance: approx. 3.5M, <100pF
AC+DC Vrms accuracy=ACV accuracy + DCV accuracy
Accuracy*
0.7% + 2
1.0% + 5
50 ~ 500Hz
50 f 60Hz: 1.0% + 5
60 < f 400Hz: 5.0% + 5
Crest factor effects
1.4 < CF 2.0: add 1.0% of reading to accuracy
2.0 < CF 2.5: add 2.5% of reading to accuracy
2.5 < CF 3.0: add 4.0% of reading to accuracy
Maximum input voltage: 690 Vrms CF=2 460 Vrms CF=3
Current
Rms-value detection
Function
99.99 kW
600 kW
600.0 kW**
* The measured value < 1.000kW: add 10digits to the accuracy.
**600 kW : Guaranteed accuracy (not maximum reading)
Maximum input voltage and current: 1000 Vrms, 600 Arms
Function
Resolution (Measuring range)
Accuracy
Power factor
-1.00~0.00~1.00
(3+2digits)
Maximum input voltage and current: 1000 Vrms, 600 Arms
PF: ACV 10 Vrms and ACA 5 Arms (Sine wave, 50 f 60Hz)
Resistance/Continuity check
Function
Range
Resolution
(Maximum reading)
Accuracy
1000
999.9
1.0% + 5
10 k
9.999 k
1.5% + 20
100 k
99.99 k
1.5% + 5*
1000
999.9
600 A
600.0 A***
99.99 A
600 A
600.0 A***
100 A**
99.99 A
600 A
600.0 A***
50 f 60Hz : 1.5% + 5*
60 < f 400Hz : 2.0% + 5*
50 f 60Hz : 1.5% + 5
60 < f 400Hz: 5.0% + 5
Crest factor effects
1.4 < CF 2.0: add 1.0% of reading to accuracy
2.0 < CF 2.5: add 2.5% of reading to accuracy
2.5 < CF 3.0: add 4.0% of reading to accuracy
Maximum input current: 420 Arms CF=2 280 Arms CF=3
Range
Resolution
(Maximum reading)
100 V
140.0 V
1000 V
1400 V
100 A
140.0 A
600 A
850 A
Accuracy
3.0% + 15
3.0% + 15
PEAK MAX: polarity+, polarityMaximum input voltage and current: 1000 Vrms, 600 Arms
Sine wave, ACV 5 Vrms, ACA 5 Arms, 50 to 400 Hz continuous wave
Frequency (Hz)
Function
Resolution (Measuring range)
100 Hz
20.00 to 99.99 Hz
1000 Hz
20.0 to 999.9 Hz
10 kHz
0.020 to 9.999 kHz
Accuracy
0.5% + 3
Maximum input voltage and current: 1000 Vrms, 600 Arms
Input condition; 100 V range: 10 to 100 Vrms
(Sine wave)
1000 V range: 100 to 1000 Vrms
100 A range: 10 to 100 Arms (<400Hz)
600 A range: 100 to 600 Arms (<400Hz)
The measured value < approx. 10 Hz: 0.00Hz
Harmonic Measurement
Individual Harmonic
Harmonic order
Resistance
Continuity check
1.0% + 3
1.0% + 5
The buzzer turns on for resistances lower than approx. 30. (Response time:
approx. 100msec)
Maximum input voltage: 1000 Vrms
Maximum test current: approx. 0.5mA
Open circuit voltage: approx. 3V
Diode Test
Function
Resolution (Measuring range)
Accuracy
Diode Test
0.40~0.80 V
0.1 V
Maximum test current: approx. 0.5mA
Open circuit voltage: approx. 1.8V
Peak Hold (AC mode only)
ACA
ACW: 2.5% + 11
DCW: 2.2% + 22
Power Factor
99.99 A
100 A**
Accuracy
ACW: ACV 10 Vrms and ACA 5 Arms (Sine wave, 50 f
60Hz, PF=1.00)
DCW: at DCV 10 V and DCA 5 A
100 A
*The measured value <1000digits: add 5digits to accuracy
**Input current 0.10A at 100 A range of ACA and LPF ACA
***600 A : Guaranteed accuracy (not maximum reading)
Maximum input current: 600 Arms, 848.5Apk
Conductor position effects: 1.0% of reading
AC+DC Arms accuracy=ACA accuracy + DCA accuracy
Resolution (Maximum reading)
1st to 12th (h01- h12)
Accuracy
5% + 10
99.9 %
13th to 25th (h01- h12)
10% + 10
Maximum input voltage and current: approx. 1000 Vrms, 600 Arms
The rdy is displayed at ACV < 10 Vrms, ACA < 10 Arms
The OutF is displayed at f < 45, 65 < f (f: fundamental frequency)
Inrush Current
ACA
100 kW
Accuracy*
LPF
ACA
Function
9.999 kW*
Range
ACA
ACV
Resolution
(Maximum reading)
10 kW
Resolution
(Maximum reading)
DCA
Function
ACW
DCW
Range
Range
Resolution
(Maximum reading)
Accuracy
100 A
99.99 A
2.5% + 20
600 A
600.0 A*
2.5% + 5
Maximum input current: approx. 600 Arms
*600 A : Guaranteed accuracy (not maximum reading)
100A range: ACA1 10 Arms (Sine wave, 50Hz/60Hz)
General Specifications
Display count:
Measuring rate:
Over range indicator:
Auto Power Off:
Low-battery indicator:
Power supply:
Battery life:
9999 / 6000
3 times / sec.
OL or -OL
Approx. 15 minute.
(four steps)
9V alkaline battery (6LR61)
When using alkaline battery, backlight off
Approx. 20 hours
Operating temperature and humidity: 0 ~ 50 C (with no condensation)
80% RH (0 ~ 30 C)
75% RH (30 ~ 40 C)
45% RH (40 ~ 50 C)
Temperature coefficient: At 0 to 18 C and 28 to 50 C
Add 235 C accuracy x 0.2 / C
Storage temperature:
-10 to 50 C, 80% RH or less (remove the battery)
Withstand voltage:
AC 6880 Vrms 5 sec. (between the core and the case)
AC 4300 Vrms 5 sec.
(between the core and the voltage input terminals)
AC 6880 Vrms 5 sec.
(between the voltage input terminals and the case)
Insulation resistance:
100M or greater at 1000 VDC
(between the core and the case, the core and the voltage input
terminals and the voltage input terminals and the case)
Compliant standards:
Safety standards: EN 61010-1, EN 61010-2-032
1000V CAT.III, 600V CAT.IV
EN 61010-031 (the test leads)
Pollution degree 2, Indoor use, Altitude 2000m or less
EMC standards: EN 61326-1, EN 61326-2-1, EN 61326-2-2,
EN 55011
Dimensions:
Approx 87.5 mm(W) x 242 mm(L) x 51 mm(D)
Diameter of measurable conductors: 37mm (Maximum)
Weight:
Approx. 435g (including the battery)
Accessories:
Test leads 1set (Red and Black)
Carrying case
9V alkaline battery (6LR61)
Users Manual
600A range: ACA 100 Arms (Sine wave, 50Hz/60Hz)
Measurement time: approx. 100ms