Brand: Conventional Transformer

Faraday's first transformer consisted of coils wrapped around an iron ring. Henry's coil used copper strips wrapped in silk insulation. The Zipernowski-Deri transformer of 1885 had an improved design with primary and secondary coils insulated and wound around an iron core. Modern transformers come in interconnecting and autotransformer designs. An interconnecting transformer provides galvanic insulation between primary and secondary networks while an autotransformer gives a lighter, more economical solution for voltage ratios between 1 and 2. The costs of early transformers were problematic due to inefficient iron designs that were difficult and expensive to wind and repair. Modern transformer costs depend on customer specifications, with more complex designs costing more, though manufacturers strive to

Uploaded by

Zamira Jamil
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
73 views5 pages

Brand: Conventional Transformer

Faraday's first transformer consisted of coils wrapped around an iron ring. Henry's coil used copper strips wrapped in silk insulation. The Zipernowski-Deri transformer of 1885 had an improved design with primary and secondary coils insulated and wound around an iron core. Modern transformers come in interconnecting and autotransformer designs. An interconnecting transformer provides galvanic insulation between primary and secondary networks while an autotransformer gives a lighter, more economical solution for voltage ratios between 1 and 2. The costs of early transformers were problematic due to inefficient iron designs that were difficult and expensive to wind and repair. Modern transformer costs depend on customer specifications, with more complex designs costing more, though manufacturers strive to

Uploaded by

Zamira Jamil
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 5

BRAND

CONVENTIONAL TRANSFORMER

Picture 1: Faraday's first transformer

Picture 2: Henry's Coil

Picture 3: Zipernowski-Deri Transformer

MODERN TRANSFORMER

Picture 4: interconnecting and auto-transformer

Company

: Alstom

Type

: PTR L 1 Transfo-MD

STRUCTURE
CONVENTIONAL TRANSFORMER
Faradays First Transformer:
A soft iron ring 7/8 if an inch thick and 6 inches in external diameter. Three coils of each
wire was wounded around one half of the rings circumference. Each coil had 24 feet of wire
with the turns separated by wine and calico. 60 feet of wire in two separate coils was wounded in
the same direction at the other side. The two coils were connected in series and carried the
connecting wire over magnetic needle. Other part of the coils were then connected to a battery
and closed the circuit. The magnetic side on the second side will immediately sense it, oscillated
and then returned to its original position.
Henrys coil:
Not so much different with Faradays First transformer. The coils are made of copper
strips which have been wrapped in silk insulation.
The Zipernowski and Deri Transformer
This is the one of the best design of the early ring-shaped transformer that invented by the
Messrs Karoly Zipernowski and Miksa Deri in 1885. The positions of the coils and the iron were
reversed, both primary and secondary coils were insulated, and were wounded into a kind of slid
core and over-wound with a heavy layer of iron wire.

MODERN INTERCONNECTING AND AUTOTRANSFORMER

1. HV Bushings
2. HV neutral bushing
3. LV bushing
4. Oil conservator
5. On-load-tap-changer
6. Motor drive for OLTC
7. Pressure relief device
8. Jacking supports
9. Oil draining and filtering valve
10.Oil filtering valve
11.Control cabinet
12.Oil temperature indicator
13.Winding temperature indicator
14.Buchholz relay
15.Dehydrating breather
16.Magnetic oil level indicator
17.Wheels
18.Coolers
19.Motopumps
This type of transformer offers a galvanic insulation between primary and
secondary networks and high adaptability to expected levels of performance and
site conditions. Meanwhile, the autotransformer gives a lighter and more
economically optimized solution which is possible whenever the voltage ratio is
between 1 and 2.

COST
CONVENTIONAL TRANSFORMER
At that time, (1800-1900) the question of the costs become a problem as the shape of the
iron punching made them wasteful and expensive. This is because of the iron on the periphery
was difficult to wind and any repairs requires tearing the whole thing to pieces.

MODERN TRANSFORMER
As the world become more advanced, the design and use of transformers also become
more innovative. The cost of the modern transformer depends on the specs that the customers
choose. More specifics can lead to the higher price. However, the inverter of company nowadays
tend to build a new and cheaper version of the transformer.