MBS - Kat 2008 Engl

Download as pdf or txt
Download as pdf or txt
You are on page 1of 352

Dear Customer,

realizing today, on what is apparent to others


only tomorrow represents a part of the success of
MBS AG.
We proudly present in our new catalogue our fullest product range of low voltage current
transformers for industrial and tariff applications as well as our voltage transformers,
measuring transducers, energy meters, and bus bar isolators and -supports.
The name of MBS is symbolic for innovation and know-how Made in Germany. For more
than 30 years, our world-wide customers are taking advantage of our vast selection of
product availability combined with our highest standard of quality. Our numerous international certificates and licences are mirrowing MBSs standard.
Our one to one consultation is readily available to you when searching together for
solutions to your requirements whilst maintaining the highest standard quality of supply
according to DIN EN ISO 9001.
My colleagues and I are looking forward to working with you.
Please take advantage of our short delivery times and optimal solutions.
MBS AG guarantees your success.

Yours,

Wolfgang Gilgen
Prof. Dr. h.c.

MBS AG

MBS AG
Eisbachstrae 51
74429 Sulzbach-Laufen
Sulzbach Messwandler
GERMANY
Tel.: +49 7976 9851-0
Fax: +49 7976 9851-90
E-mail: [email protected]
www.mbs-stromwandler.de
The descriptions in this catalogue are not binding.
We are not liable for any printing mistakes.
With the publication of this catalogue, any previously issued
information is rendered invalid.

MBS AG

Contents
About us . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
MBS distributors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
MBS product groups summarized . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Type annotation of MBS current transformers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
MBS current transformers summarized . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
Current transformers Technical characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22

Low voltage current transformers for industrial applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29


Tube current transformers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29/30
Tube current transformers, resin hardened . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37
Tube current transformers for panel boards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .39
Plug-in current transformers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41
Wound current transformers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .97
Split core current transformers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .107
Summation current transformers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .111
NH-current transformers for fuse rails . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .117
Protection tube current transformers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .123
Protection plug-in current transformers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .126
Three-phase current transformer sets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .155

Low voltage current transformers for tariff applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .165


Tube current transformers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .166
Plug-in current transformers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .167
Wound current transformers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .193/194
Summation current transformers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .193/195
Three-phase current transformers sets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .197

Accessories for low voltage current transformers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .203


Snap-on mountings . . . . . . . .
Copper tubes, mounting angle
Mounting kit, secondary caps .
Locking pistons . . . . . . . . . . .
Sealed shutters . . . . . . . . . . . .
Copper bus bars . . . . . . . . . . .

.
.
.
.
.
.

.
.
.
.
.
.

.
.
.
.
.
.

.
.
.
.
.
.

.
.
.
.
.
.

.
.
.
.
.
.

.
.
.
.
.
.

.
.
.
.
.
.

.
.
.
.
.
.

.
.
.
.
.
.

.
.
.
.
.
.

.
.
.
.
.
.

.
.
.
.
.
.

.
.
.
.
.
.

.
.
.
.
.
.

.
.
.
.
.
.

.
.
.
.
.
.

.
.
.
.
.
.

.
.
.
.
.
.

.
.
.
.
.
.

.
.
.
.
.
.

.
.
.
.
.
.

.
.
.
.
.
.

.
.
.
.
.
.

.
.
.
.
.
.

.
.
.
.
.
.

.
.
.
.
.
.

.
.
.
.
.
.

.
.
.
.
.
.

.
.
.
.
.
.

.
.
.
.
.
.

.
.
.
.
.
.

.
.
.
.
.
.

.
.
.
.
.
.

.
.
.
.
.
.

.
.
.
.
.
.

.
.
.
.
.
.

.
.
.
.
.
.

.
.
.
.
.
.

.
.
.
.
.
.

.
.
.
.
.
.

.
.
.
.
.
.

.
.
.
.
.
.

.
.
.
.
.
.

.
.
.
.
.
.

.
.
.
.
.
.

.
.
.
.
.
.

.
.
.
.
.
.

.
.
.
.
.
.

.
.
.
.
.
.

.
.
.
.
.
.

.
.
.
.
.
.

.
.
.
.
.
.

.204
.204
.205
.205
.205
.206

Bus bar isolators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .209/210


Bus bar supports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .209/214
Additional products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .221
Shunts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .223
Amperemeters change-over switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .228
NEOZED fuse base, contact tongue . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .228

Voltage transformers for low voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .229


1-pole isolated, 2-pole isolated . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .230

Measuring transducers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .235


SWMU .
NMC . . .
FASK . .
EMBSIN
Order list

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.
.
.
.
.

.236
.239
.242
.244
.269

Electronic energy meters for industrial applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .291


Single-phase energy meters, direct measuring . . . . . . . . . . . . . . . . . . . . . .
Three-phase energy meters, direct measuring . . . . . . . . . . . . . . . . . . . . . . .
Three-phase energy current transformer meters . . . . . . . . . . . . . . . . . . . . .
Three-phase energy current transformer meters, front mounted 96 x 96 mm

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

. . . .292
. . . .298
. . . .304
. . . .313

Electro-mechanical energy meters for industrial applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .317


Electronic energy meters for tariff applications (calibrated) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .319
Single-phase energy meters, direct measuring . . . . . . .
Three-phase energy meters, direct measuring . . . . . . . .
Three-phase energy current transformer meters . . . . . .
Electro-mechanical energy meters for tariff applications

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

www.mbs-stromwandler.de

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.
.
.
.

.320
.323
.336
.349

MBS AG

About us
The Zhleranstalt Rudolf Khler (ZARK), founded in the year 1925, was instrumental in the
inauguration during 1977 through Wolfgang Gilgen, managing director and owner, in the todays
very successful organization MBS AG.
Further business involvement and investments follow at home and abroad.

1977
MBS is located in Baden-Wrttemberg, in the
vicinity of Stuttgart. The organization is known
very soon for the superior performance of its
products, its great innovative strength, and the
continuous growth of the business. MBS produce
initially only a limited number of current transformers. Measuring performances, innovations,
and maximal product reliability lead in a short
time to obtain a greater, and growing share of
the market.

1985
Since 1985 MBS represents Staatlich anerkannte Prfstelle fr Messgerte fr Elektrizitt EA90
(a state registered testing office for measuring
instruments for electricity). This acculate was only
bestowed on MBS for their continued optimal
performance on measuring realibility and user
friendly safety of their products.

1987
The first works in Sulzbach-Laufen soon reaches
its capacity limit due to the marketing
success, increasing sales and an ever expanding
product range. MBS is compelled to enlarge their
production and storage facilities. A second works
is created which is adapted to cater for further
eventualities.

www.mbs-stromwandler.de

MBS AG

1995
MBS receives the quality certificate DIN EN
ISO 9001 issued by TV Mannheim. This
distinction opens the door for the worldwide
activities. Already in this year MBS is exporting
to more than 20 countries.

1998
Our products are certified by the GL Germanischer Lloyd GL Type Approval Certificate.

2000
MBS views the future optimistically and will
consider at all times the implementation of new
challenges. A fully automated production line for
metal and synthetic materials is installed. Due to
the constant growth in the demand for measuring
transducers only the best state-of-the-art up
technology is aquired and implemented.

1997
The worldwide activites of MBS Sulzbach Messwandler GmbH are a challenge for the company
administration. An architecturally challenging as
well as highly functional multipurpose building is
completed in the Eisbachstrae 51. Today we find
here the headquarter of the MBS group of companies.
Production and warehouse facilities are not confined just to Sulzbach-Laufen, but also extend to
a neighbouring town. In Slovenia MBS MT is born
to produce the cores for our current transformers.

www.mbs-stromwandler.de

MBS AG

2004
The expansion of the product range as well as
the custom made units contribute further to the
sales successes.
To satisfy the demands of our customers, it is
necessary to increase the production capacity.
At the same time, costs in manufacturing had to
be reduced. With these tasks in mind a new
modern storage and logistic center is introduced
at the main factory in Sulzbach-Laufen.

2005
MBS again increase their turnover. More and
more customers believe in the product and
acknowledge the high quality and professionalism
of MBS.
A subsidiary is established in North RhineWestphalia, as well as offices in London MBS
Sulzbach Messwandler Limited and in Slovenia
MBS-CT d.o.o..

2006
A further expansion is being implemented for the
mechanical production of synthetic materials and
enlargement of the product range.
Another two-storey building is purchased complete with offices and facilities for the production
of cores for the current transformers. This manufacturing site is equipped with machinery for steel
band cutting of all sizes, core winding machines,
core heating furnaces as well as overhead mobile
cranes for transporting heavy loads.

2007
MBS AG is born.
A subsidiary is established in northern Germany
to serve northern Europe.
Very senior engineers are employed in management to meet the ever increasing work load.
At our three production centres, situated in the
Federal Republic of Germany, on an area spanning more than 12.000 m2, 4.700 transformers
Made in Europe are built per day, in multi-shift
operation, locally to 100 % in Baden-Wrttemberg.
More than 20.000 products are supplied to all
continents.
6

www.mbs-stromwandler.de

MBS AG

Our expectations for the future


Realizing today, on what others think only tomorrow is our motto. More engagement, more service, and more customer satisfaction, are at all
times the goals of MBS.

An extremely long list of orders making full use of


our production capacity, ensures that we can look
into a successful future.

The management and all employees are highly


motivated, as well as customer oriented, and
know the importance of service, quality responses, innovation and assisting the customer by
providing the shortest delivery times whenever
possible. This can only be achieved by means of
hand-in-glove cooperation between the various
departments. These efforts are clearly reflected in
our customers in the home and export markets
as well as our continuously growing customer
base consisting of well-known international organizations covering industry and energy supply
companies. We are proud of the results of our
hands-on activities. However, the past whilst very
encouraging is now consigned to history.

We expect an increase in customers as well as


distributors. We have to be prepared and not
lose-out at what we have created.
The foundation is in place and improvements are
beggin. The tools for refinements are in place. An
important focus is to keep our administrative
staff fully informed of up-to-date computer technology, which is only one of many tasks.

Please visit our MBS homepage:


www.mbs-stromwandler.de

www.mbs-stromwandler.de

MBS AG

Headquarters
MBS AG
Eisbachstrae 51
74429 Sulzbach-Laufen
Sulzbach Messwandler
Germany
Tel.: +49 7976 9851-0
Fax: +49 7976 9851-90
E-mail: [email protected]

MBS AG
Northern Europe
Am Seedeich 9-11
27472 Cuxhaven
Sulzbach Messwandler
Germany
Tel.: +49 4721 399039
Fax: +49 4721 399047
E-mail: [email protected]

MBS Sulzbach Messwandler Ltd


Hans Gerlach
P.O.Box 31635, London W11 3WF
England
Tel.: +44 20 77273254
Fax: +44 20 72219445
E-mail: [email protected]

Works 2:
Eisbachstrae 33
74429 Sulzbach-Laufen
Germany
Works 3:
Eugen-Hahn-Strae 35
73565 Spraitbach
Germany

www.mbs-stromwandler.de

December 2007

MBS AG

Domestic
Baden-Wrttemberg
Baden
Henry Wollschlger
Industrievertretung-Elektrotechnik
Seckacher Str. 158
68259 Mannheim
Tel.: +49 621 7140-427
Fax: +49 621 7140-527
E-mail:
[email protected]
Wrttemberg
MDB Blechschmidt
Weier Weg 30
74417 Gschwend
Tel.: +49 7972 72066
Fax: +49 7972 6398
E-mail:
[email protected]

Bayern
Franken, Niederbayern,
Oberpfalz
Ing.-Bro Beyer
Elektroingenieurbro
Hauptstr. 33
91094 Langensendelbach
Tel.: +49 9133 5983
Fax: +49 9133 9877
E-mail: [email protected]
Sdbayern
Ing. Adolf Mller GmbH
Industrievertretungen
Elly-Staegmeyr-Strae 15
80999 Mnchen
Tel.: +49 89 8126-044
Fax: +49 89 8126-925
E-mail: [email protected]

Berlin
Ingenieurbro
Gnter Hentschel
Paul-Lincke-Ufer 39/40
10999 Berlin
Tel.: +49 30 617895-0
Fax: +49 30 617895-11
E-mail: [email protected]

Brandenburg
Ingenieurbro
Gnter Hentschel
Paul-Lincke-Ufer 39/40
10999 Berlin
Tel.: +49 30 617895-0
Fax: +49 30 617895-11
E-mail: [email protected]
December 2007

Bremen
Ingenieurbro Breuell
Techn. Vertretungen GmbH
Grtzmhlenweg 40
22339 Hamburg
Tel.: +49 40 538092-10
Fax: +49 40 538092-85
E-mail: [email protected]

Hamburg
Ingenieurbro Breuell
Techn. Vertretungen GmbH
Grtzmhlenweg 40
22339 Hamburg
Tel.: +49 40 538092-10
Fax: +49 40 538092-85
E-mail: [email protected]

Hessen
H.-J. Ehrlich KG
Automation + Energietechnik
Kurmainzer Str.45
65929 Frankfurt/Main
Tel.: +49 69 860066-0
Fax: +49 69 860066-30
E-mail: [email protected]

Mecklenburg-Vorpommern
Ingenieurbro Breuell
Techn. Vertretungen GmbH
Grtzmhlenweg 40
22339 Hamburg
Tel.: +49 40 538092-10
Fax: +49 40 538092-85
E-mail: [email protected]

Niedersachsen
Fritsche Industrievertretungen
GmbH
Grohorst 15
30916 Isernhagen
Tel.: +49 5136 8893-0
Fax: +49 5136 8893-20
E-mail: [email protected]

Nordrhein-Westfalen
A+H
Vertriebsgesellschaft fr Gerte
der Steuer- und Regeltechnik mbH
& Co. KG
Borner Str. 31
42897 Remscheid
Tel.: +49 2191 9376-0
Fax: +49 2191 9376-76
E-mail: [email protected]

Bereich: EVU
KDK Dornscheidt GmbH
Gewerbegebiet Oberpleis
In der Brckenwiese 7
53639 Knigswinter
Tel.: +49 2244 91994-0
Fax: +49 2244 91994-14
E-mail: [email protected]

Sachsen
Tandel & Partner GbR
Industrievertretungen/Ing.-Bro
Mommsenstr. 2
04329 Leipzig
Tel.: +49 341 252449-0
Fax: +49 341 252449-19
E-mail: [email protected]

Rheinland-Pfalz
Henry Wollschlger
Industrievertretung-Elektrotechnik
Seckacher Str. 158
68259 Mannheim
Tel.: +49 621 7140-427
Fax: +49 621 7140-527
E-mail:
[email protected]

Sachsen-Anhalt
Tandel & Partner GbR
Industrievertretungen/Ing.-Bro
Mommsenstr. 2
04329 Leipzig
Tel.: +49 341 252449-0
Fax: +49 341 252449-19
E-mail: [email protected]

H.-J. Ehrlich KG
Automation + Energietechnik
Kurmainzer Str.45
65929 Frankfurt/Main
Tel.: +49 69 860066-0
Fax: +49 69 860066-30
E-mail: [email protected]

Schleswig-Holstein
Ingenieurbro Breuell
Techn. Vertretungen GmbH
Grtzmhlenweg 40
22339 Hamburg
Tel.: +49 40 538092-10
Fax: +49 40 538092-85
E-mail: [email protected]

Saarland
Henry Wollschlger
Industrievertretung-Elektrotechnik
Seckacher Str. 158
68259 Mannheim
Tel.: +49 621 7140-427
Fax: +49 621 7140-527
E-mail:
[email protected]

Thringen
Industrievertretung
Gebr. Gritz GmbH
Feldstr. 1
99334 Ichtershausen
Tel.: +49 3628 62917-0
Fax: +49 3628 640284
E-mail: [email protected]

www.mbs-stromwandler.de

MBS AG

Europe
Europe
Austria
Fischmeister Handelsges. mbH
Herzogstr. 58
4060 Leonding
Tel.: +43 70 651642-0
Fax: +43 70 651642-20
E-mail: [email protected]

Croatia
Tomas & Co.
Kopilica 9
21000 Split
Tel.: +385 21 490643
Fax: +385 21 490642
E-mail: [email protected]

Belgium
Verdoolaege NV
Meet- en regeltechniek
Noorderlaan 117
2030 Antwerpen
Tel.: +32 35 411111
Fax: +32 35 410635
E-mail: [email protected]

Denmark
DEIF A/S
Frisenborgvej 33
7800 Skive
Tel.: +45 9614 9614
Fax: +45 9614 9615
E-mail: [email protected]

Bulgaria
GTT Engineering Ltd.
10 Yurij Venelin str.
9004 Varna
Tel.: +359 52 636728
Fax: +359 52 602393
E-mail: [email protected]
Czech Republic
GHV Trading spol.s.r.o
Kounicova 67a
602 00 Brno
Tel: +420 541 2355-32, -33, -34
Fax:+420 541 235387
E-mail: [email protected]

10

Estonia
Klinkmann Eesti As
Mehaanika 2 B
10602 Tallinn
Tel.: +372 668 4500
Fax: +372 668 4501
E-mail:
[email protected]
Finland
Shklehto OY
Holkkitie14
00880 Helsinki
Tel.: +358 97 746420
Fax: +358 97 591071
E-mail: [email protected]

www.mbs-stromwandler.de

OY KLINKMANN
P.O.Box 38
00371 Helsinki
Tel.: +358 9 540 4940
Fax: +358 9 541 3541
E-mail: [email protected]

0,4 KV Kereskedelmi Kft.


Illatos t 38/a.
1097 Budapest
Tel.: +36 12 811850
Fax: +36 12 811851
E-mail: [email protected]

Greece
2KAPPA LTD
Sofokli Venizelou 13
54628 Menemeni Thessaloniki
Tel.: +30 2310 775510-13
Fax: +30 2310 775514-15
E-mail: [email protected]

Latvia
Klinkmann Lat Ltd.
Ganib dambis 2a
1045 Riga
Tel.: +371 738 1617
Fax: +371 738 2451
E-mail: [email protected]

VIMKA Ltd
Neoktista Aspropyrgou
19300 Aspropyrgos
Attikis/Athens
Tel.: +30 210 5590870,
5590759
Fax: +30 210 5590832
E-mail: [email protected]

Lithuania
UAB Klinkmann Lit
Smolensko str. 10
03201 Vilnius
Tel.: +370 5 215 1646
Fax: +370 5 216 2641
E-mail: [email protected]

Hungary
Duvalex BT fr Handel +
Dienstleistungen
Szrny u. 6
1173 Budapest
Tel.: +36 12 572217
Fax: +36 12 572217
E-mail: [email protected]

UAB Klinkmann Lit


Kauno str. 21A
91558 Klaipeda
Tel.: +370 46 310 850
Fax: +370 46 310 850
E-mail: [email protected]

MBS AG
Outside Europe
Norway
DEIF Norge AS
Dvleveien 41
3170 Sem
Tel. +47 3338 1600
Fax: +47 3338 1601
E-mail: [email protected]

Slovenia
TDR Trading d.o.o.
Ul. 10. oktobra 9
2000 Maribor
Tel.: +386 22 294650
Fax: +386 22 522401
E-mail: [email protected]

Poland
ASTAT sp. z o.o.
ul. Dabrowskiego 441
60-451 Poznan
Tel.: +48 61 8488871
Fax: +48 61 8488276
E-mail: [email protected]

Sweden
Beving Elektronik AB
Box 93
127 22 Skrholmen
Tel.: +46 8680 1199
Fax: +46 8680 1188
E-mail: [email protected]

Portugal
SISACOL SISTEMAS DE
AUTOMACAO E CONTROLE, LDA
Rua das Flores, no16 - R/C
Esquerdo
Quinta do Brasileiro
2855-199 Corroios
Tel.: +351 21 2549280
Fax: +351 21 2549288
E-mail: [email protected]

Switzerland
Liechtenstein
WISAR Wyser + Anliker AG
Steinackerstrae 29
8302 Kloten
Tel.: +41 44 81522 33
Fax: +41 44 81522 60
E-mail: [email protected]

Romania
Business for Business
Str Gara Herastrau nr. 4 - Etaj. IV
Bucharest-Sector 2
020334 Bucharest
Tel.: +40 21 2329502, 2329503
Fax: +40 21 2329294
E-mail: [email protected]
COELCO TRADE
19C, Iuliu Maniu Av.
061076 Bucharest
Tel.: +40 21 4119621/51
Fax: +40 21 4119781
E-mail: [email protected]
Russia
East-West Consulting
Am Alten Berg 7
97996 Niederstetten
Tel.: +49 7932 606456
Fax: +49 7932 606458
E-mail: [email protected]
ELECTROMASHHOLDING Ltd.
Verhnjaja Krasnoselskaja 2
Moscow, 107140
Tel.: +7 495 9805516
Fax: +7 495 9806409
E-mail: [email protected]
ETK Joule GmbH
Elektrodnaja Strasse, Haus 2, Bl. 12-14
Moscow, 111141
Tel.: +7 495 3631867
Fax: +7 495 3631867
E-mail: [email protected]
Serbia
INTERTEHNIK TRADE doo
Nebojsina 26
11000 Belgrade
Tel.: +381 11 2441536
Tel.: +381 11 3835148
Fax: +381 11 2433370
E-mail: [email protected]

The Netherlands
Controlin BV
Glasblazerstraat 1
2984 BL Ridderkerk
Tel.: +31 180 330522
Fax: +31 180 330529
E-mail: [email protected]
United Kingdom
MBS Sulzbach Messwandler Ltd
Hans Gerlach
P.O.B. 31635, London W11 3WF
Tel.: +44 20 77273254
Fax: +44 20 72219445
E-mail: [email protected]
Nortonics Foxtam Limited
Bridge Road, Camberley
Surrey, GU15 2QR
Tel.: +44 1276 25858
Fax: +44 1276 25885
E-mail:
[email protected]
Outside Europe

Bahrain
TERRAMAR GmbH
Dorotheenstr. 82
22301 Hamburg
Tel: +49 40 27073-0
Fax: +49 40 27073-350
E-mail: [email protected]
Costa Rica
Wolfgang Rodemann
11 calle 19-64 Zona15 V.H.3
Guatemala-Ciudad
Guatemala C.A.
Tel.: +502 5693 3987
Fax: +502 2364 0940
E-mail: [email protected]
Egypt
Pyram Eng. & Trading Co.
27 Aloba st off Al-Haram st,
Al-Haram Giza - P.O.Box 12111
Tel./Fax: +202 58 28541/3
+202 58 53032
E-mail: [email protected]
El Salvador
Wolfgang Rodemann
11 calle 19-64 Zona15 V.H.3
Guatemala-Ciudad
Guatemala C.A.
Tel.: +502 5693 3987
Fax: +502 2364 0940
E-mail: [email protected]
Guatemala
Wolfgang Rodemann
11 calle 19-64 Zona15 V.H.3
Guatemala-Ciudad
Guatemala C.A.
Tel.: +502 5693 3987
Fax: +502 2364 0940
E-mail: [email protected]
Honduras
Wolfgang Rodemann
11 calle 19-64 Zona15 V.H.3
Guatemala-Ciudad
Guatemala C.A.
Tel.: +502 5693 3987
Fax: +502 2364 0940
E-mail: [email protected]
Kuwait
TERRAMAR GmbH
Dorotheenstr. 82
22301 Hamburg
Tel: +49 40 27073-0
Fax: +49 40 27073-350
E-mail: [email protected]
Mexico
Wolfgang Rodemann
11 calle 19-64 Zona15 V.H.3
Guatemala-Ciudad
Guatemala C.A.
Tel.: +502 5693 3987
Fax: +502 2364 0940
E-mail: [email protected]
Oman
TERRAMAR GmbH
Dorotheenstr. 82
22301 Hamburg
Tel: +49 40 27073-0
Fax: +49 40 27073-350
E-mail: [email protected]

Peru
CEYESA
Ingenieria Elctrica S.A.
Pque. Internacional de la Industria
y Comercio
Av. Enrique Meiggs no. 255-257
Callao
Tel.: +51 1451 7936 / 452-4565
Fax: +51 1451 7272 / 451-0617
E-mail:
[email protected]
Qatar
TERRAMAR GmbH
Dorotheenstr. 82
22301 Hamburg
Tel: +49 40 27073-0
Fax: +49 40 27073-350
E-mail: [email protected]
Saudi Arabia
Specialize Symbol
P.O. Box 515
Riyadh 11421
Tel.: +966 1 476 5311
Fax: +966 1 479 3019
E-mail:
[email protected]
South Africa
Fleck Technologies (PTY) LTD
7 Van der Sterr Road
Rhodesfield extension 1, Kempton Park
1620 Johannesburg, Gauteng Province
Tel.: +27 11 3946308
Fax: +27 11 3946308
E-mail: [email protected]
Sudan
El Watania for Engineering &
Trading
270A Sudan Str.
El Mohandssen, Giza, Egypt
Tel.:+20 23025648
Fax:+20 23038613
E-mail: [email protected]
United Arab Emirates
GDS Gulf Dynamic
Switchgear Co.Ltd.
P.O.Box 6155
Sharjah
Tel: +971 6533 8568
Fax:+971 6533 6383
E-mail: [email protected]
Gama Electro-Mechanics Devices
Trdg. Co. (LLC)
P.O. Box 22185
Sharjah
Tel: +971 6533 5453
Fax: +971 6533 8182
E-mail: [email protected]
Yemen
Al Khaled For General Commercial
Agencies
P.O. Box 11153
Sanaa
Tel.: +967 1 513532
Fax: +967 1 500791
E-mail [email protected]
E-mail: [email protected]

www.mbs-stromwandler.de

11

MBS AG

MBS product groups


summarized
Low voltage current transformers for industrial applications
Class 1, 0.5, 0.2s

ASR
ASG
ASK
WSK
KBU
KSU / SUSK
NH
ASRD 14 / ASRD 210.3
ASKD / WSKD
SASR
SASK

Tube current transformers, primary round conductor


Tube current transformers, hardened
Tube current transformers for panel boards
Plug-in current transformers
Wound current transformers
Split core current transformers
Summation current transformers
Current transformers for fuse rails
Three-phase current transformer sets
Three-phase current transformer sets
with or without base plate and neutral conductor
Protection tube current transformers, primary round conductor
Protection plug-in current transformers

Low voltage current transformers for tariff applications, calibrated or suitable for calibration
Class 0.5, 0.5s, 0.2, 0.2s

EASR
EASK
EWSK
ESUSK
EASK(D)
EASKD / EWSKD

Tube current transformers, primary round conductor


Plug-in current transformers
Wound current transformers
Summation current transformers
Three-phase current transformer sets
Three-phase current transformer sets
with or without base plate and neutral conductor

Accessories for low voltage current transformers


Snap-on mountings
Copper tubes
Mounting angle, mounting kit, secondary caps
Locking pistons
Sealed shutters
Copper bus bars

Bus bar isolators/ -supports


DB/P
CO/P
CS/P
CT/P
CPE
PI/P
PSB
GB
SK

12

Spacing isolators

Ducting isolators
Vertical bus bar supports
Mounting material, threaded bolts
Hexagon spacer im brass
Bus bar supports
Bus bar support L- and Z-profile

www.mbs-stromwandler.de

MBS AG

Additional products
Shunts
Amperemeter change-over switch
Voltmeter change-over switch
NEOZED-fuse base
Contact tongue

Voltage transformers up to 1 kV
MBE / MBEV / MBER
MBZ / MBZV / MBZR

1-pole isolating voltage transformers


2-pole isolating voltage transformers

Measuring transducers
SWMU

Measuring transducers for AC current with integrated current transformer


with auxiliary voltage supply, 230 V AC
with auxiliary voltage supply, 24 V DC
without auxiliary voltage supply
Measuring transducers for AC current, for direct notching onto MBS current transformers
with auxiliary voltage supply, 230 V AC, 110 V AC
with auxiliary voltage supply, 24 V DC
without auxiliary voltage supply
measuring range 5 A or 1 A
Mounting adaptor for any type of current transformers
Short circuit adaptor
Current transformers with separable, flexible measuring system
Measuring transducers for electrical variables
AC current with/without auxiliary voltage supply
AC current with wide range auxiliary voltage supply, effective current value (RMS)
AC voltage with/without auxiliary voltage supply
AC voltage with wide range auxiliary voltage supply, effective current value (RMS)
Frequency with auxiliary voltage supply
Frequency difference with auxiliary voltage supply
Phase angle with auxiliary voltage supply
Phase angle difference with auxiliary voltage supply
Power factor with auxiliary voltage supply
Active power with auxiliary voltage supply
Reactive power with auxiliary voltage supply
Programmable measuring transducers for AC current with auxiliary voltage supply
Programmable universal measuring transducers with up to 3 analogue outputs,
with auxiliary voltage supply

NMC

NMC-AD
NMC-KSx
FASK
EMBSIN

Electronic energy meters for industrial applications


1-phase energy meters, direct reading
3-phase energy meters, direct reading
3-phase energy meters for current transformers
3-phase energy meters for current transformers, front mounted 96 x 96 mm
Electro-mechanical energy meters

Energy meters for tariff application (suitable for calibration)


1-phase energy meters, direct reading
3-phase energy meters, direct reading
3-phase energy meters for current transformers
Electro-mechanical energy meters

www.mbs-stromwandler.de

13

MBS AG

Type annotation of MBS current transformers


Our production exclusively comprises low voltage current transformers of the 0.5 series with a max. operating voltage
up to 0.72 kV, acc. to DIN VDE 0414, part 1, DIN 42600 and DIN EN 60044/1, edition 12/2003 as well as the regulation
VBG 4. For the DIN specification, the most recent information is at all times applicable.

Our delivery programm comprises:


Low voltage current transformers for industrial applications
ASR

Tube current transformers for primary nominal currents from 40 A up to 600 A, secondary
nominal currents 5 A or 1 A, optional secondary change-over function, classes 0.5 and 1,
optional with copper tube or snap-on mounting

ASK

Plug-in current transformers for primary nominal currents from 30 A up to 7500 A,


secondary nominal currents 5 A or 1 A, optional for dual or triple secondary change-over
function, classes 0.2, 0.5 and 1, without primary conductor, but with foot angle, isolator protection cap, and bus bar mounting screws, alternatively with chrome plated. Copper bus bar,
conforming to the bus bar window, inclusive of screws DIN 933, complete with nuts, U-discs
and springs for the mounting onto bus bars, or similar components

ASG

Tube current transformers for primary nominal currents from 50 A up to 300 A, secondary
nominal currents 5 A or 1 A, class 1, with fixed secondary conductors, 2.5 mm2 connections
for nominal wire cross section, measuring system resin hardened
Tube current transformers for panel boards for 50 A up to 1250 A with 13 measuring
systems integrated in one housing

WSK

Wound current transformers for primary nominal currents from 1 A up to 150 A,


secondary nominal currents 5 A or 1 A, classes 0.5 and 1, with primary winding and primary
connectors instead of a continuous bus bar

KBU

Split core current transformers for primary nominal currents from 100 A up to 5000 A,
secondary nominal currents 5 A or 1 A, classes 0.5 and 1, with a separable measuring
system for an easy fitment into an already existing installation, without additional mounting
requirements. The locking mechanism of the current transformers is to be opened for the
installation and is to be closed when the unit is in place, an audible click ensures that the
circuit is closed. This unit is ready for operating after the secondary conductors have been
connected

KSU / SUSK

Summation current transformers for primary nominal currents from 5 A up to 1 A,


secondary nominal currents 5 A or 1 A, classes 0.5 and 1. The numerals following the letter
indicate the quantity of how many primary circuits can be connected, up to 8 connections
are possible

NH

Current transformers for fuse rails for primary nominal currents from 100 A up to 600 A,
secondary nominal currents 5 A or 1 A, optional secondary change-over switch function,
class 3, secondary connections in excess of 4 mm require jacks, for direct mounting onto
the contact rail of low voltage-high performance fuses, integrated in the NH fuse set, available in sizes NH 1, NH 2 and NH 3

SASR / SASK

Protection current transformers for primary nominal currents from 50 A up to 2000 A,


secondary nominal currents 5 A or 1 A, classes 5P5, 10P5, 5P10, and 10P10. Additional
sizes are available upon request.

ASRD / ASK(D) / WSKD /


ASKD

Three-phase current transformers for primary nominal currents from 3 x 50 A up to


3 x 750 A, secondary nominal currents 5 A or 1 A, classes 0.5 and 1, optional dual secondary
change-over function

Custom-build units correspond in their construction form to the above mentioned technical norms.

14

www.mbs-stromwandler.de

MBS AG

Optimal solution for the application of tube- and plug-in current transformers for low nominal currents
Bushing type current transformers
With low measuring currents up to
approximately 50 A it is possible to use a
single-phase plug-in current transformer
instead of the normally used wound
current transformer. The prerequisite of
course is, that the primary nominal current
of the current transformer corresponds to
an integral multiple of the measuring
currents. The primary winding will in this
case be threaded once or repeatedly
through the primary conductor opening.

primary ct
nominal current
A
50

100

150

number of threads
1
2
5
10
1
2
4
5
10
20
1
2
3
5
6
10
15

primary nominal
current to be measured
A
50
25
10
5
100
50
25
20
10
5
150
75
50
30
25
15
10

Low voltage current transformers for tariff applications


EASR

Tube current transformers for primary nominal currents from 100 A up to 600 A,
secondary nominal current 5 A or 1 A, classes 0.2, 0.5s and 0.5 with type approval by PTB
Braunschweig for application for tariff purposes.

EASK

Plug-in current transformers for primary nominal currents from 25 A up to 3200 A,


secondary nominal current 5 A or 1 A, classes 0.2, 0.5s, and 0.5 with type approval for
the application for tariff purposes.

EWSK

Wound current transformers for the primary nominal current from 25 A up to 150 A,
secondary nominal currents 5 A or 1 A, classes 0.2, 0.5s and 0.5 with type approval for the
application for tariff purposes, with primary winding and primary connection terminals
instead of a primary conductor opening.

ESUSK

Summation current transformers for primary nominal currents 5 A, secondary nominal


currents 5 A, class 0.2, with type approval for the application for tariff purposes. The numerals following the letter indicate the number of how many primary circuits can be connected,
up to 8 connections are possible.

EASK(D) / EWSKD / EASKD

Three-phase current transformers for primary nominal currents from 3 x 50 A up to


3 x 750 A, secondary nominal currents 5 A or 1 A, classes 0.2, 0.5s and 0.5, optional for dual
secondary change-over function with type approval for the application for tariff purposes,
for space-saving installation in energy distribution, current transformer set, mounted with
primary connecting bus bars and integrated protection cover.

Note:
All current transformers for tariff application have been tested at the Physikalisch Technische Bundesanstalt
Braunschweig (PTB). This classification is visual on our name plate.
To differentiate between our current transformers we have arranged for the letter E to be set in front of all
other references.
www.mbs-stromwandler.de

15

MBS AG
MBS Current Transformers Summarized

Tube Current Transformers


30
ASR
14.3
(*)
Primary
nominal
current
A
1
2.5
5
10
15
20
25
30
40
50
60
75
80
100
125
150
200
250
300
400
500
600
750
800
1000
1200
1250
1500
1600
1800
2000
2500
3000
3200
4000
5000
6000
7500
primary
conductor
in mm
round
conductor
in mm
transform.
width
in mm

31

32

33

34

35

36

ASR

ASR

ASR

ASR

ASR

ASR

20.3
(*)

201.3
(*)

21.3
(*)

21.5

22.3
(*)

42.45

38

39

ASG
210.3 106
ASG

42

43

44

45

46

47

49

51

54

55

56

ASK

ASK

ASK

ASK

ASK

ASK

ASK

ASK

ASK

ASK

ASK

205.3
(*)

21.3
(*)

231.5

31.3
(*)

318.3
(*)

31.4
(*)

31.5
(*)

31.6

41.3
(*)

421.4

41.4
(*)

58
ASK
41.5

NEW

NEW
1 0.5

1
1
1.5
1.5
1.5

1 0.5

1
1.25
1.5
1.5
2.5 2.5
2.5 3.75
2.5 3.75
5
5
5 7.5
5 7.5

1
1.25
1.5
1.5
2.5 2.5
2.5 3.75
2.5 3.75
5
5
5 7.5
5 7.5

1 0.5

1
1.5
2.5
5
5
10
10
10

1 0.5

1.5 2.5
1.53.75
1.53.75
1.5 5
2.5 5
2.5 5
5 10
10 15
10 15
15 15
15 15
15 15
15 15

only for
coppertube,
cable
mounting
without
1 access.
1.5
1.5
2.5
2.5
2.5 5
5
5
10
10
10
10
10

5
10
15
15
15
15
15

1
transformer
hardened

1 0.5

only for
coppertube
cable
mounting
without
access.

1
1.25
1.5
1.5
2.5
3.75
3.75
5
7.5
7.5

2.5
5
7.5
10
10
15 sec.
connec15 tion
15 cable
400 mm
30 2.5
30 mm2

(**)
(**)
(**)
(**)
(**)
(**)
(**)
(**)
(**)
(**)
(**)
(**)
(**)
(**)
(**)
(**)
(**)
(**)

1
1
1.25
1.5
2.5
2.5
5
5
10

1 0.5

1
1.5
1.5
2.5
2.5
2.5 5
5
5
10
10
10
10
10

5
10
15
15
15
15
15

1 0.5

1.25
1 1.25
1.25 2.5
2.5 5
2.5 5 2.5
2.5 5
5
5 2.5
5
10 5
5
10 5
5
10 5
10 15 10
10 15 10
10 15 15
10

1 0.5

1 0.5

1 0.5

1 0.5

1
1.5
1
1
2.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5 2.5 2.5 2.5 5

1
2.5
2.5
2.5 2.5
2.5 5
5
5

1.5
2.5
2.5 2.5
2.5 5
5
5
5 10
10 15

2.5
5
10
10
10
10
15
10

5
10
15
15
15
15
15
15

15
15
15
15
15
15
15
15

2.5
5
5
5
10
10
15
15

2.5
5
10
10
10
10
15
15

2.5 7.5
5 10
5 15
10 15
10 15
10 15
15 15
15 15

7.5
15
15
15
30
30
30
30

15
15
15
15
15
15
15
15

1 0.5

1.5
2.5
2.5
5
5
5
10
10
15
15

1.5
1.5
2.5
2.5
5
5
5
5
10
10
15
15

1 0.5

1
1.5
2.5
3.75
5
5
10
10
10
15
15
15
30
30

1.5
1.5
2.5
2.5
2.5 3.75
5
5
5
10
10
15
15
15
10
15

5
10
10
15
15
15
15
15
30
30

sec.
1A for
this
model
only
up to
300 A

sec.
connection cable
400 mm
2.5 mm2

20 x 5 20 x10 30 x10 30 x10 31x18 30x10 30x10 30 x10 40x12 20 x10


2x20x10

2x20x10 2x20x10 20x13 32x18

40 x10
2x30x5

14

21

21

22.5

21

22.5

42

106

17.5

19.2

28

26

26

28

28

23

26

20

32

45

45

44

49.5

50

61

71

190

49.5

61

50

61

61

61

61

95

61

71

71

Primary
nominal
NEW current
0.5
1
A
1
2.5
5
10
15
20
25
30
40
1.5
50
2.5
60
2.5 2.5
75
2.5 2.5
80
2.5 3.75 100
5
5 125
7.5 7.5 150
7.5 10 200
10 15 250
15 15 300
15 15 400
15 15 500
15 15 600
15 15 750
15 15 800
15 15 1000
1200
1250
1500
1600
1800
2000
2500
3000
3200
4000
5000
6000
7500
40 x10 primary
or
conductor
2x30x5 in mm
round
32
conductor
in mm
transform.
71
width
in mm

(*) For the above mentioned summarized current transformers, snap-on mountings are available for fitment onto 35 mm DIN-rails
(DIN 50022).
Accessories
Foot- and bus bar mounting screws complete with isolating caps (shock-proof) are included in the supplies. Sealed shutters, copper
tubings, snap-on mountings and copper bus bars are available upon request. The transformers are beeing supplied with integrated
secondary locking caps, (exceptions: ASK 31.6, ASK 41.6, ASK 51.6, ASK 61.6, WSK 31.5, WSK 70.6, ASR 201.3).

16

www.mbs-stromwandler.de

Page

(*)

Accuracy classes for sec. 5 A and sec. 1 A with information of max. burden in VA

CTs with 1 up to 3 different measuring systems upon request;


for detailed information see page 39

Page

Plug-in Current Transformers

MBS AG
MBS Current Transformers Summarized

Plug-in Current Transformers


Page

59
ASK
412.4

Primary
nominal
current
A
0.5
1
1
2.5
5
10
15
20
25
30
40
50
1.5
60
1.5
75
2.5
80
2.5
100 1.5 3.75
125
150 2.5
5
200 2.5 10
250 5
10
300 5
15
400 10 15
500 10 15
600 10 15
750 15 30
800 15 30
1000
1200
1250
1500
1600
1800
2000
2500
3000
3200
4000
5000
6000
7500
primary 40 x12
conductor
in mm 30 x15
round
conductor 30.5
in mm
transform.
width
71
in mm

61
ASK
41.6

64
ASK
541.4

65
ASK
51.4

67
ASK
51.6

68
ASK
561.4

70
ASK
61.4

72
ASK
61.6

73
ASK
63.4

74
ASK
63.6

75
ASK
81.4

78

ASK
83.4

82
ASK
101.4

84
ASK
103.3

85
ASK
103.41

86
ASK
105.6

87
ASK
105.6N

Accuracy classes for sec. 5 A and sec. 1 A


with information of max. burden in VA

NEW
0.5

1 0.5

1 0.5

1.5
2.5
1.5 2.5
2.5
1.5 2.5 1.5 2.5
5
5 2.5 2.5
5
5 2.5
5
10 10 5
10
5
10
15 15 5
10
15 15 15 15
15 15 15 15
15 15 15 15
15 15 10 15
15 15 15 30
30 30 30 30
30 30 30 30
30 30 30 30
30 45 15 30

40x12

40x10

1 0.5

1 0.5

2.5 2.5 5

2.5 2.5 10
5
5 10
5
10 15
5
10 15
10 15 15
10 15 15
15 15 15
10 15 15
15 30 15
15 30 30
15 30 30
15 30 30

10
10
15
30
30
30
30
30
45
45
45
45

50x12

50x12

1 0.5

1 0.5

1 0.5

1 0.5

1 0.5

1 0.5

1 0.5

1 0.5

1 0.5

1 0.5

1 0.5

10
10
10
10
15
15
30
30
30
45
45 30
45 30

45
45

30
30

45
45

1.5 2.5

5
5
5
10
10
15
15
15
15

2.5
5
5
10
15
15
15
30
30
30
30

60x10

2.5
2.5 2.5 5
2.5 2.5 10
5
5 15
10 10 15
15 15 15
15 15 15
15 15 15
15 15 15
30 30 30
30 30 30
30 30 30
30 30 30
30 30 30

63x10

2.5
10
15
15
30
30
30
30
30
45
45
45
45
45

60x10

30x15 2x30x5 2x40x10 40x30 2x50x10 2x50x10 50x30

2.5
5
5
5
10
10
15
15
30
15
15
15

2.5 2.5
5
5
5
10
10 15
15 15
15 15
15 15
15 15
15 15
15 15
15 15
15 15
15 15 30

2.5
2.5
10
5
15
15
15
15
30
30
30
30
30

5
10
10
15
15
30
30
30
45
45

30 15

60x30 60x30
50x40

2.5 2.5
5
5
5
5 5
5
10 5
10 15 10
10 15 10
15 15 10
15 15 10
15 15 10
15 15 15
15 30 15
15 30 15
45 15 30 30
15 30 30

5
10
10
15
15
15
15
15
15
15

10
10
10
15
30
30
30
30
45
45
45
45

2.5
5
15
15
15
15
15

2.5
2.5
2.5
10 2.5
15 5
15 10
30 10
30 10
45 15
45

30
30
30

45 15
45
45

5
5
5
5
10
15
15
15
30

5
5
10
5
15
15
15
30
15
30 30
30
30

80x10 84x34 100x10 2x100x10 103x41 100x55 100x55


60x30
2x60x10
2x80x10 3x80x10

32

32

44

40

44

44

40

44

30

55

34

70

85

40

55

55

95

86

86

95

86

96

95

96

88

120

96

130

172

99

129

129

88
ASK
123.3

89
ASK
127.4
om

Primary
nominal
current
0.5
1 0.5
1
A
1
2.5
5
10
15
20
25
30
40
50
60
75
80
100
125
150
200
250
300
400
500
600
750
800
10 10 10 10 1000
15 15 15 15 1200
15 15 30 30 1250
15 30 30 30 1500
30 30 30 1600
15 30 30 30 1800
30 45 30 45 2000
30 45 45 45 2500
30 45
3000
3200
30 45
4000
5000
6000
7500
123x30 120x70 primary
conductor
3x100x10
in mm
round
100
70
conductor
in mm
transform.
172
159
width
in mm

Plug-in current transformers class 0.2s which can be supplied upon request:
ASR 22.3, ASK 21.3, ASK 31.3, ASK 31.4, ASK 41.4, ASK 541.4, ASK 51.4, ASK 61.4,
ASK 81.4, ASK 105.6, ASK 123.3, ASK 130.3, ASK 130.5

www.mbs-stromwandler.de

Page

17

MBS AG
MBS Current Transformers Summarized

Plug-in Current
Transformers

Primary
nominal
current
A
1
2.5
5
10
15
20
25
30
40
50
60
75
80
100
125
150
200
250
300
400
500
600
750
800
1000
1200
1250
1500
1600
1800
2000
2500
3000
3200
4000
5000
6000
7500
primary
conductor
in mm
round
conductor
in mm
transform.
width
in mm

90
ASK
127.6

92
ASK
128.4

93
ASK
129.10

94
ASK
130.3

95
ASK
130.5

99
WSK
30
(*)

100
WSK
40
(*)

101

WSK
40 N

102
WSK
60

Summation Current
Transformers

Split Core Current


Transformers

103
WSK
70.6

104
WSK
70.6 N

105
WSK
31.5

108
KBU
23

108
KBU
58

109
KBU
812

109
KBU
816

114
KSU
23

115
SUSK
38

118
NH

Accuracy classes for sec. 5 A and sec. 1 A


with information of max. burden in VA

NEW
0.5

1 0.5

2.5
2.5
2.5
2.5
5
10
10
10
15

5
10
30
30

10
15
30
30

30
30
30
30

30
45 15
45 15
45

30
30
30

45
45
45

120x72

1 0.5

5
5
5
5
10
15
15
15
30

5
10
10
30
30
30
30 30
30 45
45

1 0.5

15
15
15
30
30
30
30
45
45

1 0.5

1 0.5
2.5
2.5
2.5
2.5
2.5
2.5

5
10
10
10
15

5
10
10
15
15

10
10
15
15
15

10
10
15
15
15

15
15
15
30
30

30
30
30
30
30

30
30
30
30
30

30
30
30
30
30

30
30
30
30

30
30
30
45

1
5
5
5
5
5
5

0.5
15
15
15
15
15
15
15
10

1 0.5
15
15
15
15
15
15
15
10 10
10
10

1 0.5

1 0.5

10
10
10
10
10
10 10
10
10

15
15
15
15
15 10
15 10
10
10
10
10
10
10

1 0.5

1 0.5

1 0.5

1 0.5

1 0.5

15
15
15
15
15
15
15
15

10
10
10
10
10
10
10
10

15
15
15
15
15
15
15
15

15
15
15
15
15
15
15
15
15
15

15
15
15
15
15
15
15
15
15
15

45
30
45 45
45 45
128x38 120x90 130x25 130x30

38

90

25

30

205

100

250

180

180

71

71

71

1 0.5
15

1 0.5 1
30 15 30

60

60

70

30 15

23

30

38

current current
circuits circuits

1.25
1.5
1.5
1.5 1 1.5 1 1.5
1.5 3.75 1.5 2.5 1.5 2.5
2.5
5 1.5 2.5 1.5 2.5
2.5 5 2.5 5
2.5 5 2.5 5
2.5 5 2.5 7.5
2.5 5 2.5 7.5
5
10 5
10 10
5
10 10
7.5 10
7.5 15 15
15

15
15

15
15
15

15
15
30

30
30

30
30

20x30

61

1 0.5

15

45

72

15
15

50x80 80x120 80x160

20

50

80

80

93

125

155

195

57

65

(*) For the above mentioned summarized current transformers, snap-on mountings are available for fitment onto 35 mm DIN-rails
(DIN 50022).
Accessories
Foot- and bus bar mounting screws complete with isolating caps (shock-proof) are included in the supplies. Sealed shutters, copper
tubings, snap-on mountings and copper bus bars are available upon request. The transformers are beeing supplied with integrated
secondary locking caps, (exceptions: ASK 31.6, ASK 41.6, ASK 51.6, ASK 61.6, WSK 31.5, WSK 70.6, ASR 201.3).

18

www.mbs-stromwandler.de

Page

(*)

upon request / dual change-over

Page

Wound Current
Transformers

Primary
nominal
current
A
1
2.5
5
10
15
20
25
30
40
50
60
75
80
100
125
150
200
250
300
400
500
600
750
800
1000
1200
1250
1500
1600
1800
2000
2500
3000
3200
4000
5000
6000
7500
primary
conductor
in mm
round
conductor
in mm
transform.
width
in mm

MBS AG
MBS Current Transformers Summarized

Protection Current Transformers

Page

125
SASR
22.3
(*)

Primary
nominal
current
5P5 10P5
A
50
60
75
80
100
1
120
125 1.5 1.5
150 1.5 1.5
200 1.5 1.5
250 1.5 1.5
300 1.5 1.5
400
500
600
750
800
1000
1200
1250
1500
1600
1800
2000
2500
3000
4000
5000
6000
7500
primary
conductor
in mm
round
conductor 22.5
in mm
transform.
width
61
in mm

126
SASK
21.3
(*)

127
SASK
31.5
(*)

128
SASK
31.6

132
SASK
421.4

133
SASK
41.4

134
SASK
41.6

136
SASK
41.10

140
SASK
541.4

142
SASK
51.4

144
SASK
51.6

148
SASK
61.4

150
SASK
61.10

152
SASK
63.6

153
SASK
105.6

Accuracy classes for sec. 5 A and sec. 1 A


with information of max. burden in VA
5P5 10P5 5P5 10P5 5P5 10P5 5P10 10P10 5P4 5P5 10P5 5P5 10P5 5P5 10P5 5P10 10P10 5P5 10P5 5P10 10P10 5P5 10P5 5P10 10P10 5P5 10P5 5P5 10P5 5P10 10P10 5P5 10P5 5P5 10P5 5P10 10P10 5P5 10P5 5P5 10P5

2.5 2.5
2.5 2.5 1.5 1.5
1
1 2.5 2.5
1.5
1.5 1.5 5 5 1.5 2.5
1 1.5 1.5 1.5
1.5 1.5 1.5 1.5
1.5 1.5 1.5 2.5
2.5 2.5
2.5 2.5
2.5 2.5
2.5 2.5
2.5 2.5
1.5 5

7.5
10
10
10
15
15
15

7.5
10
10
10
15
15
15

2.5
2.5
5
5
5
7.5
7.5

2.5
5
5
5
5
7.5
10

2.5 2.5 1.5 1.5 10 15

2.5
2.5
2.5
2.5

2.5
2.5
2.5
2.5

2.5
2.5
2.5
2.5

1
1
1
1.5
2.5
2.5
2.5
2.5
2.5
2.5

1
1
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5

5
7.5
10
10
10
10
10

5
7.5
10
10
10
10
10

2.5
2.5
2.5
5
7.5
10
7.5

2.5
2.5
5
5
7.5
10
7.5

15
15
15
15
15
15
15
15
15

15
15
15
15
15
15
15
15
15

5 1.5 1.5

7.5
10
10
15
15
15
15
15

10
15
15
15
15
15
15
15

1.5
2.5
2.5
2.5
2.5
5
5
5
7.5

2.5
2.5
2.5
2.5
5
5
7.5
7.5
7.5

1.5
1.5
2.5
2.5
2.5

1.5
1.5
1.5
2.5
2.5
2.5

1
1.5
1.5
1.5
1.5
1.5
2.5

1
1.5
2.5
2.5
2.5
2.5
2.5
5

2.5
5
5
7.5
7.5
10
10
10

2.5
5
7.5
7.5
7.5
10
10
10

1.5
1.5
2.5
2.5
2.5
2.5
2.5
5

10 10 2.5 2.5 2.5 5 10 10 5

1.5
1.5
2.5
2.5
2.5
2.5
2.5
5
5

1.5
1.5
2.5
2.5
2.5
5
5
5
5
5

1.5
1.5
2.5
2.5
2.5
5
5

10
15
15
15
15
15

10
15
15
15
15
15

5
7.5
10
15
15
15

7.5
10
15
15
15
15

5 15 15 15
5 15 15 15
5 15 15 15
15 15 15

15
15
15
15

2.5
2.5
2.5
5
5
5
5

2.5
2.5
2.5
5
5
5 5 5
5 10 10

5 10
15
15
15
15

10
15
15
15
15

15 15 15 15

20 x 10 30 x 10

30 x 10

2 x 20 x 10

20 x 13

28

23

20 x 10

40 x 10

40 x 12

2 x 30 x 5

30 x 15

32

32

40 x 10

40 x 10

50 x 12

50 x 12

60 x 10

60 x 10

2 x 30 x 5

2 x 40 x 10

40 x 30

2 x 50 x 10

0 x 30

32

44

40

44

30

Page

Primary
nominal
current
A
50
60
75
80
100
120
125
150
200
250
300
400
500
600
750
800
1000
1200
1250
1500
1600
1800
2000
2500
3000
4000
5000
6000
7500

60 x 30 100 x 55 primary
conductor
in mm
round

19.2

20

32

30

55

conductor
in mm
transform.

61

61

95

71

71

95

150

86

86

95

96

150

88

129

width
in mm

(*) For the above mentioned summarized current transformers, snap-on mountings are available for fitment onto 35 mm DIN-rails
(DIN 50022).
Accessories
Foot- and bus bar mounting screws complete with isolating caps (shock-proof) are included in the supplies. Sealed shutters, copper
tubings, snap-on mountings and copper bus bars are available upon request. The transformers are beeing supplied with integrated
secondary locking caps, (exceptions: SASK 31.6, SASK 41.6, SASK 51.6, SASK 61.6).

www.mbs-stromwandler.de

19

MBS AG
MBS Current Transformers Summarized
Current Transformers for Tariff Application
Page

166

EASR
14.3
(*)
Primary
nominal
current
A
1
2.5
5
10
15
20
25
30
40
50
60
75
80
100
120
125
150
200
250
300
400
500
600
750
800
1000
1200
1250
1500
1600
1800
2000
2400
2500
3000
3200
4000
5000
6000
7500
primary
conductor
in mm
round
conductor
in mm
transformer
width
in mm

167
EASR
22.3
(*)

168
EASK
21.3
(*)

169
EASK
31.3
(*)

170
EASK
31.4
(*)

171
EASK
31.5
(*)

172
EASK
31.6

175
EASK
41.5

174
EASK
41.4
(*)

176
EASK
41.6

177
EASK
541.4

178
EASK
51.4

179
EASK
51.6

Page

182
EASK
61.4

(*)

Accuracy classes for sec. 5 A and sec. 1 A


with information of max. burden in VA

NEW

NEW

0.2 0.5(s) 0.2 0.5(s) 0.2

0.5(s) 0.2 0.5(s) 0.2(s) 0.5(s) 0.2 0.5(s) 0.2 0.5(s) 0.2 0.5(s) 0.2 0.5(s) 0.2 0.5(s) 0.2

0.5(s) 0.2 0.5(s) 0.2 0.5(s) 0.2

0.5(s)

2.5
1.5
1.5
1.5 1.5
2.5
2.5
2.5 2.5
5
5
5
10
10
10

1.5
1.5
2.5
2.5

2.5
2.5 1.5

2.5 1.5

2.5 2.5

2.5 2.5

5
5
5
10
10
10
10

5
5
5
10
10
10

2.5
5
5
5
5
5
5
5

5
5
5
10
10
10
15
15

2.5
5
5
5
10
10

20 x 10

1.5
5
5
5
5
5
5
5

30 x 10

2.5
5
5
10
10
10
10
10

30 x 10

5 5

5
5
10
10
10
10
10
10

5
10
15
15
15
15
15
15

30 x 10

5
10
10
10
15
15
15
15

10 1.5

2.5 1.5

15
15
15
30
30
30
30
30

5
5
5
10
10
15
15
15

30 x 10

2 x 20 x 10 2 x 20 x 10 2 x 20 x 10 20 x 13

2.5
5
5
5
10
15
15
10

2.5
2.5
2.5 2.5

2.5
2.5
5
10
10
10
10
15
15
15
15

2.5
5
5
10
15
15
15
15
15
15
15

2.5

10 2.5

5
5
10
15
15
15
15
15

15
15
15
15
15
15
30
30

15

30 15

40 x 10

40 x 10

40 x 12

2 x 30 x 5

2 x 30 x 5

30 x 15

5
10
10
15
15
15
15
15

10
15
15
15
30
30
30
30

2.5 2.5

1.5
5
5
5
10
10
15
15

2.5
5
5
5
10
10
15
15

30 15

40 x 10

5
5
10
10
10
10
15
15

10
10
15
15
15
15
15
15

15 15
15
15

50 x 12

2 x 30 x 5 2 x 40 x 10

2.5
5
5
10
10
15
15

2.5
5
10
10
15
15
15

30 10
30 15
30 15
15

30
15
30
30

50 x 12

60 x 10

40 x 30

2 x 50 x 10

14

22.5

19.2

26

28

28

23

32

32

32

32

44

40

44

44

61

61

61

61

61

95

71

71

95

86

86

95

96

Primary
nominal
current
A
1
2.5
5
10
15
20
25
30
40
50
60
75
80
100
120
125
150
200
250
300
400
500
600
750
800
1000
1200
1250
1500
1600
1800
2000
2400
2500
3000
3200
4000
5000
6000
7500
primary
conductor
in mm
round
conductor
in mm
transformer
width
in mm

(*) For the above mentioned summarized current transformers, snap-on mountings are available for fitment onto 35 mm DIN-rails
(DIN 50022).
Accessories
Foot- and bus bar mounting screws complete with isolating caps (shock-proof) are included in the supplies. Sealed shutters, copper
tubings, snap-on mountings and copper bus bars are available upon request. The transformers are beeing supplied with integrated
secondary locking caps, (exceptions: EASK 31.6, EASK 41.6, EASK 51.6, EASK 61.6, WSK 31.5).

20

www.mbs-stromwandler.de

MBS AG
MBS Current Transformers Summarized
Current Transformers for Tariff Application
Page

Primary
nominal
current
A
1
2.5
5
10
15
20
25
30
40
50
60
75
80
100
120
125
150
200
250
300
400
500
600
750
800
1000
1200
1250
1500
1600
1800
2000
2400
2500
3000
3200
4000
5000
6000
7500
primary
conductor
in mm
round
conductor
in mm
transformer
width
in mm

183
EASK
61.6

184
EASK
63.6

185
EASK
81.4

188
EASK
105.6

189
EASK
123.3

190
EASK
130.3

191
EASK
130.5

194
EWSK
31.5

195
ESUSK
2...8

Primary
nominal
current

Accuracy classes for sec. 5 A and sec. 1 A


with information of max. burden in VA
0.2 0.5(s) 0.2 0.5(s) 0.2 0.5(s) 0.2 0.5(s) 0.2 0.5(s) 0.2 0.5(s) 0.2 0.5(s) 0.2 0.5(s) 0.2

10

5
10
15
15
15
30
15

2.5
5
10
10
15
15

5
10
10
15
15
30

5
10
10
10

10
10
15 5
15 10

15
15
15
15

30
30
30
30

15
15
15
15

30
30
30
30

10
10
15
15

15
15
15
15

60 x 10

60 x 30

50 x 30

10
10
10
10
10
10

15
15
15
15
15
15

10

15

10

15
2...8
current
circuits

2.5
5
10
10
10
10
15

5
10

2.5
2.5
5
10 5

5
5
5
10

2.5
2.5
5
10

10
10
10
15

15
15
15
30
30

15
15
15
15
15

30
30
30
30
30

30
30
30
30

30
30
30
30

15
15
15
30
30

15
15
30
30
30

5
10
15
15
15

10
15
15
30
30

30

30 15

30

30
30

30 15
30 30

30
45

80 x 10 100 x 55
60 x 30
2 x 60 x10

5
10
15
15
15

123 x 30 130 x 25

130 x 30

3 x100 x10

40

30

55

55

100

25

30

95

88

120

129

172

180

180

Page

70

65

A
1
2.5
5
10
15
20
25
30
40
50
60
75
80
100
120
125
150
200
250
300
400
50
600
750
800
1000
1200
1250
1500
1600
1800
2000
2400
2500
3000
3200
4000
5000
6000
7500
primary
conductor
in mm
round
conductor
in mm
transformer
width
in mm

(*) For the above mentioned summarized current transformers, snap-on mountings are available for fitment onto 35 mm DIN-rails
(DIN 50022).
Accessories
Foot- and bus bar mounting screws complete with isolating caps (shock-proof) are included in the supplies. Sealed shutters, copper
tubings, snap-on mountings and copper bus bars are available upon request. The transformers are beeing supplied with integrated
secondary locking caps, (exceptions: EASK 31.6, EASK 41.6, EASK 51.6, EASK 61.6, WSK 31.5).
www.mbs-stromwandler.de

21

MBS AG

Current transformers Technical characteristics


Current transformers are special transformers for the proportional transformation of high currents into directly
measurable values. Their construction and physical operating principle enables a galvanic separation of the
primary circuit from the measured circuit, thereby providing a protection for sequentially connected instruments
in the event of a fault.

Rated limit current


[IPL]

value of the lowest primary current where, by the secondary measuring burden, the total
deviation of the current transformer for measuring purposes is equal to or greater than 10 %.

Rated current intensity


[IN]

is the noted specified value of the primary and secondary current on the rating plate.
Standardized primary nominal currents have the following values: 5 A, 10 A, 15 A, 20 A, 25 A,
30 A, 40 A, 50 A, 60 A, 75 A, 100 A with a decadic multiple of the previously mentioned value to
a max. of 7500 A. Standardized secondary nominal currents have the values 5 A and 1 A.

Rated power

the value of the apparent power (in a VA specified power factor), which the current transformer is intended to supply to the secondary circuit and rated burden at the rated secondary current.

Earthing of
secondary terminals

according to VDE 0141, section 5.3.4., current- and voltage transformers have to be earthed,
starting from Um = 3.6 kV. With low voltage (up to Um 1.2 kV) no earthing is required, as long
as the transformer housings have no visible exposed metal surfaces.

Phase displacement error


[]

signifies the phase shift of the primary current and the secondary current. The direction of
the indicator is arranged in such a way, that with an optimum produced current transformer
the phase displacement error is equal to zero (IEV 321-01-23 modified).
The phase displacement error is to be regarded as positive when the indicator of the
secondary current is ahead compared to the indicator of the primary current. The phase
displacement error is specified in minutes or hundredths of a radiant. Note: Strictly speaking
this definition is only valid for sinus type currents.

Accuracy class

the denotation for a current transformer whose measuring deviation remains below the prescribed operating condition.

Total measuring deviation


(Current error)

is the effective value in stationary position, and the difference between:


a) the momentary value of the primary current and
b) the momentary value of the measuring transmission of the multiplied actual secondary
current, whereby the positive indicators of the primary and secondary current correspond to
the accord for the connection denotation. The total deviation F1 is generally rendered in
the percentages of the effective value of the primary current, as per the following mathematical equation.

FI =

100
lp

1
T

(K N i S i P) 2 dt
O

F I = total measuring deviation in %


KN = rated measuring transmission
IP = effective value of the primary current

iP = momentary value of the primary current


iS = momentary value of the secondary current
T = duration of period

Max. voltage for electrical


equipment Um

this denotes the highest constant permitted value for phase to phase voltage for which the
current transformers isolation is rated.

Burden

the impedance of the secondary current is declared in ohms and power factor. The burden
is usually expressed as the apparent power in voltamperes, absorbed at a specified powerfactor and at the rated secondary current.

Rated burden

the value of the burden upon which the accurate requirements of this specifications are based.

Rated surge current


[IDYN]

peak value of the primary current, whose electro-mechanical impact is resisted by the
current transformer with short circuited secondary winding. The value of the nominal search
current IDYN has to be 2.5 x ITH. Only when there is a deviation from this value, the rating plate
has to state IDYN.

Actual transformation
ration

is the ratio of the primary nominal current to the secondary current. It is specified as an
unabridged break on the rating plate.

22

www.mbs-stromwandler.de

MBS AG

Open circuit voltage of


current transformers

Current transformers, which are not directly encumbered with a burden, are generally secondarily short circuited. A secondary open current transformer operates like a loaded one
with an almost infinitely high burden. The curve shape of the secondary current is extremely
deformed and under certain conditions voltage surges occur which can be harmful to human
beings. The amount of the induced loss motion depends on the core cross-section and the
number of secondary turns. For MBS current transformers of lower ratings and with a nominal transmission ratio up to 500/5, the peak value of this voltage is ) 200 V. For reasons of
hazard protection and to prevent magnetization of the iron core, an open secondary circuit is
to be avoided.

Bus bar cross section

The openings of our individual plug-in transformers for the acceptance of primary bus bars
or their cross-sections even when supplied with copper bus bars are not decisive for
the dimensioning of the bus bar units. The cross section of the bus bar is permitted to be
smaller over a short distance in the transformer area, provided the adjacent bus bar cross
sections are dimensioned in such a manner that any possible excess heat can easily be
absorbed.

Special configurations

Saturation transformers
Tropicalized versions
Primary nominal currents deviating from the standard series
Secondary change-over units
Deviating frequency (16 2/3 Hz up to 400 Hz)
Resin hardened for extreme mechanical demands (shakeproof)

Current error

upon request
upon request
upon request
refer to the relevant
types of cts
upon request
upon request

is the percentage deviation of the nominal transmission multiplied by the secondary current
from that of the primary current. The current error is calculated positively, should the actual
value of the secondary current exceed the nominal value.

FI =

IS K N I P
100 %
IP

F I = current error in %
I P = primary current in A (effective value)

I S = secondary current in A (effective value)


KN = rated measuring ratio

Thermal nominal
continuous rated current
[ID]

is the primary current which allows the continuous operation of the current transformer.
When using this current value, the temperature of the secondary wiring must not exceed the
prescribed values mentioned in the actual technical norms. These values are in direct relation to the isolation material class. Should a thermal rated current be defined which is larger
than the primary rated current, the preference values of 120 %, 150 % and 200 % should
reflect those of the primary rated current.

Thermal rated short-time


current
[ITH]

This value indicates the effective value of the primary current which the current transformers
can withstand with short circuited secondary winding.
Other rated measuring values as 1s, e.g. 0.5s, 2s and 3s are acceptable. The thermal short
time rated current Ith has to be stated for each current transformer.

Over-current rated limiting


factor (FS)

is the ratio of the limit rated current to the primary rated current.
Note 1: It ought to be noted that the actual over-load rated current is influenced by the
burden.
Note 2: Should the primary winding of the current transformer be short-circuited, the safety
is greatest, when the value of the over-load current limit factor FS is small.
The excess current limiting factor is indicated on the rating plate of a measuring transformer
with a nominal value after the letters FS.

The specification FS 5 signifies that the total measurement deviation of the current transformer with 5 times the primary nominal current arising from the magnetic saturation of the
iron core amounts at least at to 10 %.

Important:

All MBS current transformers are in accordance with DIN EN 60044/1 for a thermal nominal
current of I d = 1.0 x IN.

www.mbs-stromwandler.de

23

MBS AG

MBS current transformer range for tariff applications


In addition to a comprehensive selection of standard current transformers in the accuracy classes 0.5 and 1, MBS AG
manufactures an extensive product range of tariff transformers for currents between 25 A and 3200 A in the classes
0.2s, 0.2, 0.5s, and 0.5.
These approved current transformers have the national certificate of Germany and of several European countries.
The current transformers which have been approved by the Physikalisch Technische Bundesanstalt (PTB)
Braunschweig (an authorized German testing laboratory) are recognizable by a stylized
plus a construction series
number. An E is placed before the usual MBS type mark.
The calibration of the transformers is documented by an official lead seal as well as an additional affixed yellow
calibration stamp. The fees for the calibration are calculated in accordance with the applicable official regulation.

The calibration of the transformers is performed upon request at the


Staatlich anerkannte Prfstelle fr Messgerte fr Elektrizitt EA90
State Approved Testing Laboratories for Measuring Appliances for Electricity EA90
as represented by MBS AG.

Configuration of MBS low voltage current transformers


All at MBS AG manufactured low voltage current transformers correspond to
DIN VDE 0414/1; DIN 42600; and DIN EN 60044/1 edition 12/2003 as well as regulation VBG 4.
Characteristics of the current transformers:
unbreakable plastic housings
black polycarbonate
flame resistant
self-extinguishing
transformer housings are ultrasonically welded
nickel-plated secondary terminals
with plus-minus nickel-plated screw M 5x10 mm
integrated secondary locking caps.
Foot angle and bus bar mounting screws with isolating protection caps (protection-proof) are supplied free of
charge. All transformers are suitable for use on massive primary conductors as well as on flexible isolated copper
strips.
Bus bar mounting screw,
screw length (L)
25, 32, 36, 46, 54, 80 mm,
torque 0.5 Nm

Isolating protecting cap

General technical specifications:


Nominal frequency
Isolation class
Thermal nominal short-time current
Maximum operating voltage
Over-current limiting factor
Secondary nominal current
Operating temperature
Storage temperature
24

www.mbs-stromwandler.de

50 Hz (16 2/3 Hz up to 400 Hz upon request)


E
I th = 60 x I N
U m ) 0.72 kV
FS 5 up to 1500 A nominal current
FS 10 from 1600 A nominal current
5 A or 1 A
-5 C ) ) +40 C
-25 C ) ) +70 C

MBS AG

Error limit values for measuring transformers for classes 0.2 . 3


according to DIN IEC 60044/1
Class
accuracy
0.2
0.2s
0.5
0.5s
1
3

Current error ,F by
0.2 I n
0.1 I n
0.05 I n

1.2 I n
1.0 I n
%
0.2
0.2
0.5
0.5
1
3

%
0.35
0.2
0.75
0.5
1.5

%
0.75
0.35
1.5
0.75
3

Phase displacement error ,F by


1.2 I n
0.2 I n
0.1 I n
0.05 I n 0.01 I n
1.0 I n
min
min
min
min
min
10
15
30
10
10
15
30
30
45
90
30
30
45
90
60
90
180
120.0*

0.01 I n
%
0.75
1.5

* by 0.5 I N and thermal nominal continuous current

Error limit values for current transformers for protection applications


Current error F i by
1.0 I N and thermal
0.5 I N
0.2 I N
nominal continuous
current
%
%
%
1
1.5
3
3

Class
accuracy

5P
10 P

0.05 I N

Phase displacement error F i by


1.0 I N and thermal
0.5 I N
0.2 I N
0.05 I N
nominal continious
current

%
3

60
120

90

120

120

Current error Fg at nominal error current limit and nominal burden class 5P ) 5 %
class 10P ) 10 %

Maximum permissible current of copper bus bars


Dimensions and current values according to DIN 43671

Bus bar cross section


20
30
30
40
40
50
60
80
100

x
x
x
x
x
x
x
x
x

10
05
10
05
10
10
10
10
10

bus bar surface

1 bus bar
427
379
573
482
715
852
985
1240
1490

A
A
A
A
A
A
A
A
A

2 bus bars
825
672
1060
836
1290
1510
1720
2110
2480

A
A
A
A
A
A
A
A
A

3 bus bars
1180
896
1480
1090
1770
2040
2300
2790
3260

A
A
A
A
A
A
A
A
A

clear

Above values are valid for continuous current burden at approx. 30 C ambient temperature.

www.mbs-stromwandler.de

25

MBS AG

Markings of the current transformers connection terminals


The connections of all primary windings are marked with capital letters K-P1, and L-P2.
The connections of all secondary windings are marked with the corresponding lower case letters k-s1 and I-s2.
By current transformers with a multiple secondary tappings the winding end is marked I, followed by the prefix
letter I 1 , the tappings with a decreasing number of windings are sequencially numbered 2, 3 etc.
By current transformers with a multiple of independent primary windings, the terminals of the individual windings are
distinguishable from the additional capital letters set before K and L and the additional capital letters
A, B, C etc.; i.e. AK AL for the highest primary circuit, BK BL for the second primary circuit etc.;
or on each terminal pair the transmission or the ratio transmission of the individual primary windings to each other is
to be specified.

Error curves of low voltage current transformers

Nominal current range

Over current range for protection current transformer


Over current range for measuring
transformers up to FS 5

Nominal current

FS 5

10P5

Error curve for 1/4 nominal burden


Error curve for nominal burden
Magnetic saturation

26

www.mbs-stromwandler.de

10P10

MBS AG

Power requirements of measuring units and relays


Two main requirements are cited by the user for the principle demands of current transformers:
a high degree of measuring precission in the range of nominal current
a protection function in the over-load range
In order to fulfill these demands it is necessary for the assumed nominal power of a current transformer to fully
achieve the actual power requirements of the prescribed measurements.
In ascertaining the actual power requirements, consideration is to be given to power losses of the appliances to be
connected, as well as to the losses of the measuring conductor.

Power requirements of typical measuring units


Current meter soft ironed up to 100 mm
Rectifier current meter
Multi-range current meter
Current recorder
Bimetal current meter
Power meter
Power recorder
Power factor meter
Power factor recorder
Energy meter (current path)
Relay
N-relay
Over current relay
Over current time relay
Direction relay
Bimetal relay
Distance relay
Differential relay
Transformer current trip switch
Controler

0.700
0.001
0.005
0.300
2.500
0.200
3.000
2.000
9.000
0.400

0.200
3.000

7.000
1.000
0.200
1.000
5.000
5.000

1.500
0.250
5.000
9.000
3.000
5.000
12.000
6.000
16.000
1.000
14.000
6.000
6.000
10.000
11.000
30.000
2.000
15.000
150.000
180.000

VA
VA
VA
VA
VA
VA
VA
VA
VA
VA
VA
VA
VA
VA
VA
VA
VA
VA
VA
VA

Power consumption of copper wires


P=

I2 x 2 l
[VA]
qcu x 56

I
l
qcu

= secondary nominal current


= distance in m
= wire cross section in mm2

Comment: With a joint three phase current return conductor the values of P are halved.
Chart for values referring to 5 A
Nominal cross section

1m

2m

3m

4m

5m

6m

7m

8m

9m

10 m

2.5 mm2

0.36

0.71

1.07

1.43

1.78

2.14

2.50

2.86

3.21

3.57

4.0 mm

0.22

0.45

0.67

0.89

1.12

1.34

1.56

1.79

2.01

2.24

6.0 mm

0.15

0.30

0.45

0.60

0.74

0.89

1.04

1.19

1.34

1.49

10.0 mm

0.09

0.18

0.27

0.36

0.44

0.54

0.63

0.71

0.80

0.89

2
2
2

Chart for values referring to 1 A


Nominal cross section

10 m

20 m

30 m

40 m

50 m

60 m

70 m

80 m

90 m

100 m

1.0 mm

0.36

0.71

1.07

1.43

1.78

2.14

2.50

2.86

3.21

3.57

2.5 mm

0.14

0.29

0.43

0.57

0.72

0.86

1.00

1.14

1.29

1.43

4.0 mm

0.09

0.18

0.27

0.36

0.45

0.54

0.63

0.71

0.80

0.89

6.0 mm2

0.06

0.12

0.18

0.24

0.30

0.36

0.42

0.48

0.54

0.60

10.0 mm

0.04

0.07

0.11

0.14

0.18

0.21

0.25

0.29

0.32

0.36

2
2

www.mbs-stromwandler.de

27

MBS AG

Tube current transformers, series ASR

www.mbs-stromwandler.de

MBS AG

Low voltage current transformers


for industrial applications
Tube current transformers
Round conductor
Transformer width

14 mm
45 mm

ASR 20.3

Round conductor
Transformer width

21 mm
45 mm

ASR 201.3

Round conductor
Transformer width

21 mm
44 mm

ASR 21.3

Round conductor
Transformer width

22.5 mm
49.5 mm

ASR 21.5

Round conductor
Transformer width

21 mm
50 mm

ASR 22.3
ASR 22.3 2U

Round conductor
Transformer width

22.5 mm
61 mm

ASR 42.45

Round conductor
Transformer width
Transformer depth

42 mm
71 mm
45 mm

ASR 14.3
NEW

without locking cap

www.mbs-stromwandler.de

29

MBS AG

ASR 14.3
Tube current transformer
5A

1A

Accuracy class
1
0.5
Art.-no. Art.-no.
26080
26081
26082
26083
26084

Accuracy class
1
0.5
Art.-no. Art.-no.
26280
26281
26282
26283
26284

Secondary current
Primary
current
A
30
40
50
60
75

Burden
VA
1
1
1.5
1.5
1.5

Snap-on mounting

Primary conductor
Round conductor
Transformer width
Snap-on mounting
Sealed shutter
Copper tubes

30

14.0 mm
45 mm
Art.-no. 55013
see page 204

see page 204


www.mbs-stromwandler.de

MBS AG

ASR 20.3
Tube current transformer
Secondary current
Primary
current
A
50
60
75
80
100
125

150

200

250
300

Burden
VA
1
1
1.25
1.25
1.5
1.25
1.5
1.5
2.5
1.5
2.5
3.75
1.5
2.5
3.75
1.5
2.5
3.75
2.5
5
2.5
5

5A

1A

Accuracy class
3
1
0.5
Art.-no. Art.-no. Art.-no.
26027
26028
26029
26030
26031
26032
26033
26034
26011
26035
26036
26013
26037
26014
26039
26040
26041
26042
26043
26044
26045
26046
26048
26049

26015
26016
26017
26018
26019
26020
26021
26022
26023

Accuracy class
3
1
Art.-no.
26227
26228
26229
26230
26231
26232
26233
26234
26235
26236
26237
26238
26239
26240
26241
26242
26243
26244
26245
26246
26248
26249

0.5

26211
26213
26214
26215
26216
26217
26218
26219
26220
26221
26222
26223

Snap-on mounting

Primary conductor
Round conductor
Transformer width
Snap-on mounting
Sealed shutter
Copper tubes

21.0 mm
45 mm
Art.-no. 55013
see page 204

see page 204


www.mbs-stromwandler.de

31

MBS AG

ASR 201.3
Tube current transformer
Secondary current
Primary
current
A
50
60
75
80
100
125

150

200

250
300

Burden
VA
1
1
1.25
1.25
1.5
1.25
1.5
1.5
2.5
1.5
2.5
3.75
1.5
2.5
3.75
1.5
2.5
3.75
2.5
5
2.5
5

5A

1A

Accuracy class
3
1
0.5
Art.-no. Art.-no. Art.-no.
27027
27028
27029
27030
27031
27032
27033
27034
27011
27035
27036
27013
27037
27014
27039
27040
27041
27042
27043
27044
27045
27046
27048
27049

27015
27016
27017
27018
27019
27020
27021
27022
27023

Snap-on mounting

Primary conductor
Round conductor
Transformer width
Snap-on mounting
Sealed shutter
Copper tubes

32

21.0 mm
44 mm
Art.-no. 55013
see page 204

see page 204


www.mbs-stromwandler.de

Accuracy class
3
1
Art.-no.
27227
27228
27229
27230
27231
27232
27233
27234
27235
27236
27237
27238
27239
27240
27241
27242
27243
27244
27245
27246
27248
27249

0.5

27211
27213
27214
27215
27216
27217
27218
27219
27220
27221
27222
27223

MBS AG

ASR 21.3
Tube current transformer
Secondary current
Primary
current
A
100
150
200
250

300

400

500

600

Burden
VA
1
1.5
1.5
2.5
1.5
2.5
5
1.5
2.5
5
2.5
5
10
2.5
5
10
2.5
5
10

5A

1A

Accuracy class
1
Art.-no.
1023
1024
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042

Accuracy class
1
Art.-no.
1223
1224
1226
1227
1228
1229
1230
1231
1232
1233
1234
1235
1236
1237
1238
1239
1240
1241
1242

Snap-on mounting

Primary conductor
Round conductor
Transformer width
Snap-on mounting
Sealed shutter
Copper tubes

22.5 mm
49.5 mm
Art.-no. 55014
see page 204

see page 204


www.mbs-stromwandler.de

33

MBS AG

ASR 21.5
Tube current transformer
Secondary current
Primary
current
A
50
60

75

80

100

125

150

200

250

300

400

500

600

Primary conductor
Round conductor
Transformer width
Snap-on mounting
Sealed shutter
Copper tubes

34

21.0 mm
50 mm

see page 204


www.mbs-stromwandler.de

Burden
VA
1.5
2.5
1.5
2.5
3.75
1.5
2.5
3.75
1.5
2.5
5
1.5
2.5
5
1.5
2.5
5
2.5
5
10
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15

5A

1A

Accuracy class
1
0.5
Art.-no. Art.-no.
93050
93011
93051
93052
93012
93053
93054
93055
93013
93056
93057
93058
93014
93059
93060
93061
93015
93062
93016
93063
93064
93017
93065
93018
93066
93067
93019
93068
93020
93069
93070
93021
93071
93022
93072
93023
93073
93074
93024
93075
93025
93076
93026
93077
93078
93027
93079
93028
93080
93029
93081
93030
93082
93031
93083
93032
93084
93033
93085
93034
93086
93035
93087
93036
93088
93037
93089
93038
93090
93039
93091
93040
93092
93041
93093
93042

Accuracy class
1
0.5
Art.-no. Art.-no.
93250
93211
93251
93252
93212
93253
93254
93255
93213
93256
93257
93258
93214
93259
93260
93261
93215
93262
93216
93263
93264
93217
93265
93218
93266
93267
93219
93268
93220
93269
93270
93221
93271
93222
93272
93223
93273
93274
93224
93275
93225
93276
93226
93277
93278
93227
93279
93228
93280
93229
93281
93230
93282
93231
93283
93232
93284
93233
93285
93234
93286
93235
93287
93236
93288
93237
93289
93238
93290
93239
93291
93240
93292
93241
93293
93242

MBS AG

ASR 22.3
Tube current transformer
5A

Secondary current
Primary
current
A
40
50
60
75
80
100

150

200

250

300

400

500

600

Burden
VA
1
1
1.5
1
1.5
1.5
2.5
1.5
2.5
1.5
2.5
3.75
1.5
2.5
5
1.5
2.5
5
10
1.5
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15

1A

Accuracy class
1
0.5
0.2s
Art.-no. Art.-no.
Art.-no.
3034
3035
3036
3037
3038
3039
3040
3041
3042
3043
3011
V04-1304C
3044
3134
3045
3046
3012
V04-1604C
3047
3013
V04-1604D
3048
3138
3014
3049
3015
V04-1704D
3050
3016
V04-1704F
3051
3017
3052
3018
V04-1804D
3053
3019
V04-1804F
3054
3020
3055
3056
3022
V04-1904D
3057
3023
V04-1904F
3058
3024
3059
3060
3025
V04-2004D
3061
3026
V04-2004F
3062
3027
3063
3064
3028
V04-2104D
3065
3029
V04-2104F
3066
3030
V04-2104H
3067
3068
3031
V04-2204D
3069
3032
V04-2204F
3070
3033
V04-2204H
3071

Accuracy class
1
0.5
Art.-no. Art.-no.
3234
3235
3236
3237
3238
3239
3240
3241
3242
3243
3211
3244
3334
3245
3246
3212
3247
3213
3248
3338
3214
3249
3215
3250
3216
3251
3217
3252
3218
3253
3219
3254
3220
3255
3256
3222
3257
3223
3258
3224
3259
3260
3225
3261
3226
3262
3227
3263
3264
3228
3265
3229
3266
3230
3267
3268
3231
3269
3232
3270
3233
3271

ASR 22.3 2U
Primary conductor
Round conductor
Transformer width
Snap-on mounting
Sealed shutter
Copper tubes
Protection plug-in current
transformer
Current transformer for
tariff applications

Secondary current
22.5 mm
61 mm
Art.-no. 53011
see page 204
Art.-no. 59040
see page 205
see page 204
see page 125

Primary
current
A
200-100
300-150
400-200
500-250
600-300

see page 167

Burden
VA
5-2.5
5-2.5
10-5
5-2.5
10-5
5-2.5
10-5
5-2.5
10-5

5A

1A

Accuracy class
1
Art.-no.
3111
3112
3113
3114
3115
3116
3117
3118
3119

Accuracy class
1
Art.-no.
3311
3312
3313
3314
3315
3316
3317
3318
3319

www.mbs-stromwandler.de

35

MBS AG

ASR 42.45
Tube current transformer
Secondary current
Primary
current
A
150
200

250

300

400

500

600

750

800

1000

Burden
VA
1.5
2.5
1.5
2.5
5
1.5
2.5
5
7.5
2.5
5
10
2.5
5
10
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
5
10
15
30
5
10
15
30

5A

1A

Accuracy class
1
Art.-no.
26500
26501
26502
26503
26504
26505
26506
26507
26508
26509
26510
26511
26512
26513
26514
26515
26516
26517
26518
26519
26520
26521
26522
26523
26524
26525
26526
26527
26528
26529
26530
26531
26532
26533
26534

Accuracy class
1
Art.-no.
26600
26601
26602
26603
26604
26605
26606
26607
26608
26609
26610
26611
26612
26613
26614
26615
26616
26617
26618
26619
26620
26621
26622
26623
26624
26625
26626
26627
26628
26629
26630
26631
26632
26633
26634

Connection cable 2.5 mm2, 400 mm long.


The wire ends are complete with multi-bush wire ends.

Primary conductor
Round conductor
Transformer width
Transformer depth
Snap-on mounting
Sealed shutter

36

42 mm
71 mm
45 mm

www.mbs-stromwandler.de

MBS AG

Tube current transformers


ASG 210.3

Round conductor
Transformer width

21 mm
44 mm

Round conductor
Transformer width

106 mm
190 mm

resin hardened

ASG 106
NEW
resin hardened

www.mbs-stromwandler.de

37

MBS AG

ASG 210.3
Tube current transformer
resin hardened

Secondary current
Primary
current
A
50
60
75
80
100
125

150

200

250

300

Burden
VA
1
1
1.25
1.25
1.5
1.25
1.5
1.5
2.5
1.5
2.5
3.75
1.5
2.5
3.75
1.5
2.5
5
2.5
5
7.5
2.5
5
7.5

5A

1A

Accuracy class
1
Art.-no.
27500
27501
27502
27503
27504
27505
27506
27507
27508
27509
27510
27511
27512
27513
27514
27515
27516
27517
27518
27519
27520
27521
27522
27523

Accuracy class
1
Art.-no.
27600
27601
27602
27603
27604
27605
27606
27607
27608
27609
27610
27611
27612
27613
27614
27615
27616
27617
27618
27619
27620
27621
27622
27623

Connection cable 2.5 mm2, 400 mm long.

Primary conductor
Round conductor
Transformer width
Snap-on mounting
Sealed shutter
Copper tubes

38

21 mm
44 mm

see page 204


www.mbs-stromwandler.de

MBS AG

ASG 106
Tube current transformer
for panel boards
Features/benefits
tube current transformer with 13 measuring systems integrated in one
housing
rated voltage 0.72 kV/3 kV
primary current range 50 A 1250 A
secondary currents 1 A or 5 A
nominal burden 2.5 VA up to 30 VA
accuracy classes 0.2 / 0.5 / 0.5s / 1 / 5P / 10P
thermal nominal continuous current 1.2 x IN
it is possible to integrate into one housing a combination of measuring transformers and protection transformers
measuring systems with hardened Polyurethan resin
reliable results under extreme mechanical and climatic conditions
a choice of 4 types of housings with different depths to accommodate
special demands
reduction of external wiring by means of fixed flexible connection terminals
Application
Current transformers of the type ASG 106 have been designed to cater for
panel boards. Solidly installed flexible terminal connections as well as a large
primary conductor opening with a 106 mm diameter, ensure a time saving and
an easy assembly. The modular arrangement of the transformer make it possible
to use a multiple of different types of current transformers in one housing.

Technical data ASG 106


Type

Housing material
Max. operating voltage Um
Isolation test voltage
Rated-held-short time
alternating voltage
(coil test)
Nominal rated frequency

Low voltage current transformer,


single-phase
Measuring system with Polyurethan resin, UL94-VO, hardened
ABS / UL94-VO
0.72 kV
3 kV UEFF.; 50 Hz; 1 min.

3 kV
50 Hz,
other frequencies upon request
Secondary connection cable flexible copper wire,
4.0 mm2, HO7V-K1X4,
length 3.6 m
Primary rated
current intensity
50 ... 1250 A
Secondary rated
current intensity
5 A or 1 A
Secondary rated
assumed data burden
2.5 15 VA
2.5 30 VA
Accuracy classes
0.2
0.5
1
10P10 ... 30
5P10 ... 30
Overload current limiting factor FS 5 or FS 10
Thermal continuous
I D = 1.2 x I N,
rated current intensity
other values upon request

Short time excess current


Thermal nominal
short time current
Nominal dynamic
short time current
Temperature environmental
range
Max. permissable excess
temperature of the
primary current
Isolation class
Climatic condition
Constant technical
standards
Dimensions: b x h x d
Primary conductor guide

1.5 x IN / 60 min
2.0 x IN / 30 min
ITH = 25 kA / 3 sek.
(other values upon request)
IDYN = 60 x I N, 1 sec; max.100 kA
-5 C < <+60 C

70 C
E
suitable for tropical climates
DIN EN 60044/1 (issue 12/2003)
DIN VDE 0414/1
190 x 190 x (50,100,170,214*) mm
diameter 106 mm

* Depth dependent on the number and type of the chosen


measuring system

www.mbs-stromwandler.de

39

MBS AG

MBS AG

Low voltage current transformers


for industrial applications
Plug-in current transformers
ASK 205.3

Primary conductor
Round conductor
Transformer width

20 x 5 mm
17.5 mm
49.5 mm

ASK 21.3

Primary conductor
Round conductor
Transformer width

20 x 10 mm
19.2 mm
61 mm

ASK 231.5

Primary conductor
Round conductor
Transformer width

30 x 10 mm
28 mm
50 mm

ASK 31.3
ASK 31.3 2U

Primary conductor

ASK 318.3

Primary conductor
Round conductor
Transformer width

ASK 31.4
ASK 31.4 2U
ASK 31.4 3U

Primary conductor

ASK 31.5
ASK 31.5 2U

Primary conductor

ASK 31.6

Primary conductor

Round conductor
Transformer width

Round conductor
Transformer width

Round conductor
Transformer width

30 x 10
2 x 20 x 10
26
61

mm
mm
mm
mm

31 x 18 mm
26 mm
61 mm

30 x 10
2 x 20 x 10
28
61

mm
mm
mm
mm

30 x 10
2 x 20 x 10
28
61

mm
mm
mm
mm

30 x 10
20 x 13
23
95

mm
mm
mm
mm

Round conductor
Transformer width
www.mbs-stromwandler.de

41

MBS AG

ASK 205.3
Plug-in current transformer
Secondary current
Primary
current
A
60
75
80
100
150
200
250
300
400

Burden
VA
1
1
1.25
1.25
1.5
1.5
2.5
1.5
2.5
2.5
5
2.5
5
2.5
5
10

Snap-on mounting

Primary conductor
Round conductor
Transformer width
Snap-on mounting
Sealed shutter

42

20 x 5 mm
17.5 mm
49.5 mm
Art.-no. 55014
see page 204

www.mbs-stromwandler.de

5A

1A

Accuracy class
1
Art.-no.
2019
2020
2021
2022
2023
2024
2025
2026
2027
2028
2029
2030
2031
2032
2033
2034

Accuracy class
1
Art.-no.
2219
2220
2221
2222
2223
2224
2225
2226
2227
2228
2229
2230
2231
2232
2233
2234

MBS AG

ASK 21.3
Plug-in current transformer
Secondary current
Primary
current
A
40
50
60
75
80
100

150

200

250

300

400

500

600

Primary conductor
Round conductor
Transformer width
Snap-on mounting
Sealed shutter
Protection plug-in
current transformer
Current transformer for
tariff applications

Burden
VA
1
1
1.5
1
1.5
1.5
2.5
1.5
2.5
1.5
2.5
5
1.5
2.5
5
1.5
2.5
5
10
1.5
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15

5A
Accuracy class
1
0.5
0.2s
Art.-no. Art.-no.
Art.-no.
6034
6035
6036
6037
6038
6039
6040
6041
6042
6043
6011
6044
6111
6045
6046
6012
V10-1604C
6047
6013
V10-1604D
6048
6074
6014
6049
6015
V10-1704D
6050
6016
V10-1704F
6051
6017
6052
6018
V10-1804D
6053
6019
V10-1804F
6054
6020
6055
6056
6022
V10-1904D
6057
6023
V10-1904F
6058
6024
6059
6060
6025
V10-2004D
6061
6026
V10-2004F
6062
6027
6063
6064
6028
V10-2104D
6065
6029
V10-2104F
6066
6030
6067
6068
6031
6069
6032
6070
6033
6071

1A
Accuracy class
1
0.5
Art.-no. Art.-no.
6234
6235
6236
6237
6238
6239
6240
6241
6242
6243
6211
6244
6311
6245
6246
6212
6247
6213
6248
6274
6214
6249
6215
6250
6216
6251
6217
6252
6218
6253
6219
6254
6220
6255
6256
6222
6257
6223
6258
6224
6259
6260
6225
6261
6226
6262
6227
6263
6264
6228
6265
6229
6266
6230
6267
6268
6231
6269
6232
6270
6233
6271

20 x 10 mm
19.2 mm
61 mm
Art.-no. 53011
see page 204
Art.-no. 59040
see page 205
see page 126
see page 168
www.mbs-stromwandler.de

43

MBS AG

ASK 231.5
Plug-in current transformer
Secondary current
Primary
current
A
50
60
75
80
100
125
150
200
250
300
400

500

600

Primary conductor
Round conductor
Transformer width
Snap-on mounting
Sealed shutter

44

30 x 10 mm
28.0 mm
50 mm

www.mbs-stromwandler.de

Burden
VA
1
1,25
1
1,25
1,25
2,5
1,25
1,5
2,5
1,5
2.5
1.5
2.5
2.5
5
2.5
5
2.5
5
2.5
5
10
2.5
5
10
2.5
5
10

5A

1A

Accuracy class
1
0,5
Art.-no. Art.-no.
92050
92051
92052
92053
92054
92055
92056
92059
92060
92062
92020
92063
92065
92023
92066
92068
92026
92069
92071
92028
92072
92029
92074
92030
92075
92077
92032
92078
92033

Accuracy class
1
0,5
Art.-no. Art.-no.
92250
92251
92252
92253
92254
92255
92256
92259

92081
92082
92083
92085
92086
92087

92035
92036
92038
92039

92262
92263
92265
92266
92268
92269
92271
92272
92274
92275
92277
92278
92279
92281
92282
92283

92220
92223
92226
92228
92229
92230
92232
92233
92235
92236

MBS AG

ASK 31.3
Plug-in current transformer
5A

Secondary current
Primary
current
A
50
60
75
80
100
150
200

250

300

400

500

600

750

Burden
VA
1
1
1
1.5
1.5
2.5
1.5
2.5
1.5
2.5
1.5
2.5
5
1.5
2.5
5
10
1.5
2.5
5
10
1.5
2.5
5
10
2.5
5
10
2.5
5
10
15
2.5
5
10

1A

Accuracy class
1
0,5
0,2s
Art.-no. Art.-no.
Art.-no.
7038
7039
7040
7041
7042
7043
7044
7011
7045
7012
7046
7013
V11-1604C
7047
7014
7048
7015
7049
7016
V11-1704D
7050
7017
7051
7018
7052
7019
V11-1804D
7053
7020
V11-1804F
7054
7055
7021
7056
7022
V11-1904D
7057
7023
V11-1904F
7058
7059
7060
7025
V11-2004D
7061
7026
V11-2004F
7062
7027
7063
7028
V11-2104D
7064
7029
V11-2104F
7065
7030
7066
7031
V11-2204D
7067
7032
V11-2204F
7068
7033
7069
7034
7070
7035
V11-2304D
7071
7036
V11-2304F
7072
7037

Accuracy class
1
0,5
Art.-no. Art.-no.
7238
7239
7240
7241
7242
7243
7244
7211
7245
7212
7246
7213
7247
7214
7248
7215
7249
7216
7250
7217
7251
7218
7252
7219
7253
7220
7254
7255
7221
7256
7222
7257
7223
7258
7224
7259
7260
7225
7261
7226
7262
7227
7263
7228
7264
7229
7265
7230
7266
7231
7267
7232
7268
7233
7269
7234
7270
7235
7271
7236
7272
7237

ASK 31.3 2U
Secondary current
Primary conductor
Round conductor
Transformer width
Snap-on mounting
Sealed shutter
Current transformer for
tariff applications

30 x 10 mm
2 x 20 x 10 mm
26 mm
61 mm
Art.-no. 53011
see page 204
Art.-no. 59040
see page 205

Primary
current
A
200-100
300-150
400-200
500-250
600-300

see page 169

Burden
VA
5-2.5
5-2.5
5-2.5
10-5
5-2.5
10-5
10-5
15-7.5

5A

1A

Accuracy class
1
Art.-no.
7111
7112
7113
7114
7115
7116
7117
7118

Accuracy class
1
Art.-no.
7311
7312
7313
7314
7315
7316
7317
7318

www.mbs-stromwandler.de

45

MBS AG

ASK 318.3
Plug-in current transformer
5A

1A

Accuracy class
1
0.5
Art.-no. Art.-no.
29042
29043
29044
29045
29046
29047
29011
29048
29012
29049
29013
29050
29014
29052
29016
29053
29017
29055
29019
29056
29020
29057
29059
29023
29060
29024
29061
29063
29027
29064
29028
29065
29029
29066
29030
29067
29031
29068
29032
29069
29033
29070
29034
29071
29035
29072
29036
29073
29037
29074
29038
29075
29039
29076
29040

Accuracy class
1
0.5
Art.-no. Art.-no.
29242
29243
29244
29245
29246
29247
29211
29248
29212
29249
29213
29250
29214
29252
29216
29253
29217
29255
29219
29256
29220
29257
29259
29223
29260
29224
29261
29263
29227
29264
29228
29265
29229
29266
29230
29267
29231
29268
29232
29269
29233
29270
29234
29271
29235
29272
29236
29273
29237
29274
29238
29275
29239
29276
29240

Secondary current
Primary
current
A
60
75
80
100
150
200
250

300

400

500

600

750

Burden
VA
1
1
1.5
1.5
2.5
1.5
2.5
1.5
2.5
2.5
5
2.5
5
10
2.5
5
10
2.5
5
10
2.5
5
10
2.5
5
10
15
2.5
5
10
15

Snap-on mounting
Primary conductor
Round conductor
Transformer width
Snap-on mounting
Sealed shutter

46

31 x 18 mm
26.0 mm
61 mm
Art.-no. 53011
see page 204
Art.-no. 59040
see page 205
www.mbs-stromwandler.de

MBS AG

ASK 31.4
Plug-in current transformer
Secondary current
Primary
current
A
50
60
75
80
100

150

200

250

300

400

500

600

750

Primary conductor
Round conductor
Transformer width
Snap-on mounting
Sealed shutter
Current transformer for
tariff applications

30 x 10 mm
2 x 20 x 10 mm
28 mm
61 mm
Art.-no. 54011
see page 204
Art.-no. 59041
see page 205

Burden
VA
1.25
1.5
1.25
1.5
1.5
2.5
1.5
2.5
1.5
2.5
3.75
5
1.5
2.5
5
7.5
2.5
5
10
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15

5A
Accuracy class
1
0.5
0.2s
Art.-no. Art.-no.
Art.-no.
8157
8038
8158
8039
8041
8042
8043
8044
8045
8011
8046
8010
8152
8047
8048
8012
V14-1604C
8049
8013
V14-1604D
8050
8410
8051
8052
8014
V14-1704D
8053
8015
V14-1704F
8054
8055
8016
V14-1804D
8056
8017
V14-1804F
8057
8058
8059
8018
V14-1904D
8060
8019
V14-1904F
8061
8020
8062
8063
8021
V14-2004D
8064
8022
V14-2004F
8065
8023
8066
8067
8025
V14-2104D
8068
8026
V14-2104F
8069
8027
8070
8071
8029
V14-2204D
8072
8030
V14-2204F
8073
8031
V14-2204H
8074
8032
8153
8033
V14-2304D
8154
8034
V14-2304F
8155
8035
V14-2304H
8156
8036

1A
Accuracy class
1
0.5
Art.-no. Art.-no.
8357
8238
8358
8239
8241
8242
8243
8244
8245
8211
8246
8210
8276
8247
8248
8212
8249
8213
8250
8251
8252
8214
8253
8215
8254
8255
8216
8256
8217
8257
8258
8259
8218
8260
8219
8261
8220
8262
8263
8221
8264
8222
8265
8223
8266
8224
8267
8225
8268
8226
8269
8227
8270
8228
8271
8229
8272
8230
8273
8231
8274
8232
8353
8233
8354
8234
8355
8235
8356
8236

Change-over transformers see page 48.

see page 170


www.mbs-stromwandler.de

47

MBS AG

ASK 31.4 2U
Plug-in current transformer
Secondary current
Primary
current
A
200-100
300-150
400-200
500-250
600-300

Burden
VA
5-2.5
5-2.5
10-5
5-2.5
10-5
5-2.5
10-5
5-2.5
10-5
15-7.5

5A

1A

Accuracy class
1
Art.-no.
8117
8118
8119
8120
8121
8122
8123
8124
8125
8126

Accuracy class
1
Art.-no.
8317
8318
8319
8320
8321
8322
8323
8324
8325
8326

ASK 31.4 3U
Secondary current
Primary
current
A
300-200-100
400-200-100
600-300-150
600-400-200

Burden
VA
10-5-2.5
10-5-2.5
10-5-2.5
15-10-5
10-5-2.5
15-10-5

Snap-on mounting
Primary conductor

30 x 10 mm
2 x 20 x 10 mm
28 mm
61 mm
Art.-no. 54011
see page 204
Art.-no. 59041
see page 205

Round conductor
Transformer width
Snap-on mounting
Sealed shutter
Current transformer for
tariff applications

48

see page 170

www.mbs-stromwandler.de

5A

1A

Accuracy class
1
Art.-no.
8137
8138
8139
8140
8141
8142

Accuracy class
1
Art.-no.
8337
8338
8339
8340
8341
8342

MBS AG

ASK 31.5
Plug-in current transformer
Secondary current
Primary
current
A
40
50
60
75
80

100

150

200

250

300

400

500

600

750
Primary conductor
Round conductor
Transformer width
Snap-on mounting
Sealed shutter
Protection plug-in
current transformer
Current transformer for
tariff applications

30 x 10 mm
2 x 20 x 10 mm
28 mm
61 mm
Art.-no. 55011
see page 204
Art.-no. 59041
see page 205

Burden
VA
1
1.5
2.5
1.5
2.5
1.5
2.5
1.5
2.5
5
1.5
2.5
5
2.5
5
7.5
2.5
5
10
15
5
10
15
5
10
15
5
10
15
30
5
10
15
30
5
10
15
30
5
10
15
30

5A

1A

Accuracy class
1
0.5
Art.-no. Art.-no.
9043
9045
9046
9047
9048
9049
9011
9050
9012
9051
9013
9052
9014
9053
9054
9015
9055
9016
9056
9017
9057
9018
9058
9019
9059
9060
9020
9061
9021
9062
9022
9063
9064
9023
9065
9024
9066
9025
9067
9026
9068
9027
9069
9028
9070
9029
9071
9030
9072
9031
9073
9074
9032
9075
9033
9076
9034
9077
9078
9035
9079
9036
9080
9037
9081
9082
9038
9083
9039
9084
9040
9085

Accuracy class
1
0.5
Art.-no. Art.-no.
9243
9245
9246
9247
9248
9249
9211
9250
9212
9251
9213
9252
9214
9253
9254
9215
9255
9216
9256
9217
9257
9218
9258
9219
9259
9260
9220
9261
9221
9262
9222
9263
9264
9223
9265
9224
9266
9225
9267
9226
9268
9227
9269
9228
9270
9229
9271
9230
9272
9231
9273
9274
9232
9275
9233
9276
9234
9277
9278
9235
9279
9236
9280
9237
9281
9282
9238
9283
9239
9284
9240
9285

see page 127

Change-over transformers see page 50.


see page 171

www.mbs-stromwandler.de

49

MBS AG

ASK 31.5 2U
Plug-in current transformer
Secondary current
Primary
current
A
150-75
200-100
300-150

400-200

500-250

600-300

Burden
VA
5-2.5
5-2.5
10-5
5-2.5
10-5
15-7.5
5-2.5
10-5
15-7.5
5-2.5
10-5
15-7.5
5-2.5
10-5
15-7.5

Snap-on mounting

Primary conductor

30 x 10 mm
2 x 20 x 10 mm
28 mm
61 mm
Art.-no. 55011
see page 204
Art.-no. 59041
see page 205

Round conductor
Transformer width
Snap-on mounting
Sealed shutter
Protection plug-in
current transformer
Current transformer for
tariff applications

50

see page 127


see page 171

www.mbs-stromwandler.de

5A

1A

Accuracy class
1
Art.-no.
9132
9133
9134
9135
9136
9137
9138
9139
9140
9141
9142
9143
9144
9145
9146

Accuracy class
1
Art.-no.
9332
9333
9334
9335
9336
9337
9338
9339
9340
9341
9342
9343
9344
9345
9346

MBS AG

ASK 31.6
Plug-in current transformer
Secondary current
Primary
current
A
30
40
50
60

75
80

100

150

200

250

300

400

500

600

750
Primary conductor
Round conductor
Transformer width
Snap-on mounting
Sealed shutter
Protection plug-in
current transformer
Current transformer for
tariff applications

30 x 10 mm
20 x 13 mm
23 mm
95 mm

Art.-no. 59044
see page 205

Burden
VA
1.5
1.5
2.5
1.5
2.5
1.5
2.5
5
2.5
5
2.5
5
10
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
5
10
15
5
10
15
5
10
15
5
10
15
5
10
15
5
10
15

5A

1A

Accuracy class
1
0.5
Art.-no. Art.-no.
10054
10056
10057
10011
10058
10012
10013
10059
10014
10060
10061
10015
10062
10016
10063
10017
10064
10018
10065
10066
10019
10067
10020
10068
10021
10069
10022
10070
10023
10071
10024
10072
10025
10026
10073
10027
10074
10028
10075
10029
10076
10030
10077
10031
10078
10032
10079
10034
10080
10035
10081
10036
10082
10038
10083
10039
10084
10040
10085
10042
10086
10043
10087
10044
10088
10046
10089
10047
10090
10048
10091
10050
10092
10051
10093
10052

Accuracy class
1
0.5
Art.-no. Art.-no.
10254
10256
10257
10211
10258
10212
10213
10259
10214
10260
10261
10215
10262
10216
10263
10217
10264
10218
10265
10266
10219
10267
10220
10268
10221
10269
10222
10270
10223
10271
10224
10272
10225
10226
10273
10227
10274
10228
10275
10229
10276
10230
10277
10231
10278
10232
10279
10234
10280
10235
10281
10236
10282
10238
10283
10239
10284
10240
10285
10242
10286
10243
10287
10244
10288
10246
10289
10247
10290
10248
10291
10250
10292
10251
10293
10252

see page 128


see page 172

www.mbs-stromwandler.de

51

MBS AG

MBS AG

Plug-in current transformers


ASK 41.3

Primary conductor
Round conductor
Transformer width

40 x 12
32 x 18
26
61

ASK 421.4

Primary conductor
Round conductor
Transformer width

20 x 10 mm
20 mm
71 mm

ASK 41.4
ASK 41.4 2U
ASK 41.4 3U

Primary conductor

ASK 41.5

Primary conductor

40 x 10 mm

Round conductor
Transformer width

32 mm
71 mm

Round conductor
Transformer width

ASK 412.4
ASK 412.4 2U
ASK 412.4 3U

Primary conductor

ASK 41.6

Primary conductor

40 x 10
2 x 30 x 5
32
71

Round conductor
Transformer width

Round conductor
Transformer width

www.mbs-stromwandler.de

mm
mm
mm
mm

mm
mm
mm
mm

40 x 12
30 x 15
30.5
71

mm
mm
mm
mm

40 x 12
30 x 15
32
95

mm
mm
mm
mm

53

MBS AG

ASK 41.3
Plug-in current transformer
Secondary current
Primary
current
A
100
150
200
250

300

400

500

600

750

800

Burden
VA
1
1.5
1.5
2.5
1.5
2.5
1.5
2.5
5
1.5
2.5
5
1.5
2.5
5
1.5
2.5
5
10
1.5
2.5
5
10
2.5
5
10
15
2.5
5
10
15

Snap-on mounting

Primary conductor
Round conductor
Transformer width
Snap-on mounting
Sealed shutter

54

40 x 12 mm
32 x 18 mm
26.0 mm
61 mm
Art.-no. 53011
see page 204
Art.-no. 59040
see page 205
www.mbs-stromwandler.de

5A

1A

Accuracy class
1
Art.-no.
11037
11038
11039
11040
11041
11042
11043
11044
11045
11046
11047
11048
11049
11050
11051
11052
11053
11054
11055
11056
11057
11058
11059
11060
11061
11062
11063
11064
11065
11066
11067

Accuracy class
1
Art.-no.
11237
11238
11239
11240
11241
11242
11243
11244
11245
11246
11247
11248

MBS AG

ASK 421.4
Plug-in current transformer
Secondary current
Primary
current
A
30
40
50
60

75
80
100

125

150

200

250

300

400

500

Primary conductor
Round conductor
Transformer width
Snap-on mounting
Sealed shutter
Protection plug-in
current transformers

Burden
VA
1
1.5
1.5
2.5
1.5
2.5
3.75
5
2.5
5
2.5
5
2.5
5
10
2.5
5
10
2.5
5
10
2.5
5
10
15
5
10
15
5
10
15
5
10
15
30
5
10
15
30

5A

1A

Accuracy class
1
0.5
Art.-no. Art.-no.
12033
12034
12035
12011
12036
12037
12012
12038

Accuracy class
1
0.5
Art.-no. Art.-no.
12233
12234
12235
12211
12236
12237
12212
12238
12239

12039
12040
12041
12042
12043
12044
12045
12046
12047
12048
12049
12050
12051
12053
12054
12055
12056
12057
12058
12059
12060
12061
12062
12063
12064
12065
12066
12067

12013
12014
12015
12016
12017
12018
12019
12020
12021
12022

12023
12024
12025
12026
12027
12028
12029
12030
12031
12032

12240
12241
12242
12243
12244
12245
12246
12247
12248
12249
12250
12251
12253
12254
12255
12256
12257
12258
12259
12260
12261
12262
12263
12264
12265
12266
12267

12213
12214
12215
12216
12217
12218
12219
12220
12221
12222

12223
12224
12225
12226
12227
12228
12229
12230
12231
12232

20 x 10 mm
20 mm
71 mm

Art.-no. 59041
see page 205
see page 132

www.mbs-stromwandler.de

55

MBS AG

ASK 41.4
Plug-in current transformer
Secondary current
Primary
current
A
50
60
75
80
100

150

200

250

300

400

500

600

750
Primary conductor

40 x 10 mm
2 x 30 x 5 mm
32 mm
71 mm
Art.-no. 55012
see page 204
Art.-no. 59041
see page 205

Round conductor
Transformer width
Snap-on mounting
Sealed shutter
Protection plug-in
current transformer
Current transformer for
tariff applications

56

see page 133


see page 174

www.mbs-stromwandler.de

800

1000

Burden
VA
1.25
1.5
1.25
1.5
1.5
2.5
1.5
2.5
1.5
2.5
3.75
1.5
2.5
5
1.5
2.5
5
10
1.5
2.5
5
10
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
5
10
15
30
5
10
15
30

5A
Accuracy class
1
0.5
0.2s
Art.-no. Art.-no.
Art.-no.
13180
13036
13181
13037
13039
13040
13041
13042
13043
13011
13044
13083
13179
13046
13012 V24-1604C
13047
13013 V24-1604D
13048
13084
13014 V24-1704C
13049
13015 V24-1704D
13050
13085 V24-1704F
13051
13016
13052
13017 V24-1804D
13053
13086 V24-1804F
13054
13055
13018 V24-1904D
13056
13019 V24-1904F
13057
13087
13058
13059
13020 V24-2004D
13060
13021 V24-2004F
13061
13088 V24-2004H
13062
13063
13022 V24-2104D
13064
13023 V24-2104F
13065
13024 V24-2104H
13066
13089
13067
13025 V24-2204D
13068
13026 V24-2204F
13069
13027
13070
13090
V24-2304D
13071
13028 V24-2304F
13072
13029 V24-2304H
13073
13091
13075
13030
13076
13031
13077
13078
13079
13032
13080
13033
13081
13034
13082

1A
Accuracy class
1
0.5
Art.-no. Art.-no.
13380
13236
13238
13237
13239
13240
13241
13242
13243
13211
13244
13283
13245
13246
13212
13247
13213
13248
13284
13214
13249
13215
13250
13285
13251
13216
13252
13217
13253
13286
13254
13255
13218
13256
13219
13257
13287
13258
13259
13220
13260
13221
13261
13288
13262
13263
13222
13264
13223
13265
13224
13266
13289
13267
13225
13268
13226
13269
13227
13270
13290
13271
13272
13273
13275
13276
13277
13278
13279
13280
13281
13282

13228
13229
13291
13230
13231

13232
13233
13234

MBS AG

ASK 41.4 2U
Plug-in current transformer
Secondary current
Primary
current
A
200-100
300-150
400-200
500-250
600-300
800-400

1000-500

Burden
VA
5-2.5
5-2.5
10-5
5-2.5
10-5
5-2.5
10-5
5-2.5
10-5
5
5-2.5
10-5
15-7.5
5-2.5
10-5
15-7.5

5A

1A

Accuracy class
1
Art.-no.
13133
13134
13135
13136
13137
13138
13139
13140
13141
13177
13142
13143
13144
13145
13146
13147

Accuracy class
1
Art.-no.
13333
13334
13335
13336
13337
13338
13339
13340
13341
13342
13343
13344
13345
13346
13347

ASK 41.4 3U
Secondary current
Primary
current
A
400-200-100
600-300-150
800-400-200
1000-500-250

Primary conductor
Round conductor
Transformer width
Snap-on mounting
Sealed shutter
Protection plug-in
current transformer
Current transformer for
tariff applications

40 x 10 mm
2 x 30 x 5 mm
32 mm
71 mm
Art.-no. 55012
see page 204
Art.-no. 59041
see page 205

Burden
VA
10-5-2.5
10-5-2.5
10-5-2.5
10-5-2.5
15-7.5-2.5

5A

1A

Accuracy class
1
Art.-no.
13163
13164
13165
13166
13167

Accuracy class
1
Art.-no.
13363
13364
13365
13366
13367

Snap-on mounting

see page 133


see page 174

www.mbs-stromwandler.de

57

MBS AG

ASK 412.4
Plug-in current transformer
Secondary current
Primary
current
A
50
60
75
80
100

150

200

250

300

400

500

600

750

800

Primary conductor
Round conductor
Transformer width
Snap-on mounting
Sealed shutter

40 x 12 mm
30 x 15 mm
30.5 mm
71 mm
Art.-no. 55012
see page 204
Art.-no. 59041
see page 205

Burden
VA
1.25
1.5
1.25
1.5
1.5
2.5
1.5
2.5
1.5
2.5
3.75
1.5
2.5
5
2.5
5
10
1.5
2.5
5
10
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
5
10
15
30
5
10
15
30

5A

1A

Accuracy class
1
0.5
Art.-no. Art.-no.
28036
28037
28038
28039
28040
28041
28042
28043
28044
28011
28045
28046
28047
28012
28048
28013
28049
28051
28015
28052
28053
28054
28016
28055
28017
28056
28014
28057
28058
28018
28059
28019
28060
28061
28062
28020
28063
28021
28064
28009
28065
28066
28022
28067
28023
28068
28024
28069
28070
28025
28071
28026
28072
28027
28073
28074
28028
28075
28029
28076
28010
28077
28078
28030
28079
28031
28080
28035
28081

Accuracy class
1
0.5
Art.-no. Art.-no.
28236
28237
28238
28239
28240
28241
28242
28243
28244
28211
28245
28246
28247
28212
28248
28213
28249
28251
28215
28252
28253
28254
28216
28255
28217
28256
28214
28257
28087
28258
28218
28259
28219
28260
28261
28262
28220
28263
28221
28264
28209
28265
28266
28222
28267
28223
28268
28224
28269
28270
28225
28271
28226
28272
28227
28273
28274
28228
28275
28229
28276
28210
28277
28278
28230
28279
28231
28280
28235
28281

www.mbs-stromwandler.de

59

MBS AG

ASK 412.4 2U
Plug-in current transformer
Secondary current
Primary
current
A
200-100
300-150
400-200
500-250
600-300
800-400

Burden
VA
5-2.5
5-2.5
10-5
5-2.5
10-5
5-2.5
10-5
5-2.5
10-5
5-2.5
10-5
15-7.5

5A

1A

Accuracy class
1
Art.-no.
28133
28134
28135
28136
28137
28138
28139
28140
28141
28143
28144
28145

Accuracy class
1
Art.-no.
28333
28334
28335
28336
28337
28338
28339
28340
28341
28343
28344
28345

ASK 412.4 3U
Secondary current
Primary
current
A
400-200-100

Burden
VA
10-5-2.5
15-7.5-2.5
600-300-150 10-5-2.5
800-400-200 10-5-2.5

Snap-on mounting
Primary conductor
Round conductor
Transformer width
Snap-on mounting
Sealed shutter

60

40 x 12 mm
30 x 15 mm
30.5 mm
71 mm
Art.-no. 55012
see page 204
Art.-no. 59041
see page 205
www.mbs-stromwandler.de

5A

1A

Accuracy class
1
Art.-no.
28163

Accuracy class
1
Art.-no.

28164
28165

28363
28364
28365

MBS AG

ASK 41.6
Plug-in current transformer
Secondary current
Primary
current
A
50
60
75

80
100

150

200

250

300

400

500

600

750
Primary conductor
Round conductor
Transformer width
Snap-on mounting
Sealed shutter
Protection plug-in
current transformer
Current transformer for
tariff applications

40 x 12 mm
30 x 15 mm
32 mm
95 mm

Art.-no. 59044
see page 205
see page 134
see page 176

800

1000

Burden
VA
1.5
2.5
1.5
2.5
1.5
2.5
5
2.5
5
2.5
5
10
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
5
10
15
30
5
10
15
30
10
15
30
5
10
15
30
45

5A

1A

Accuracy class
1
0.5
Art.-no. Art.-no.
14060
14011
14061
14062
14012
14063
14064
14065
14013
14066
14014
14067
14015
14068
14016
14069
14017
14070
14018
14071
14019
14020
14072
14021
14073
14022
14074
14023
14024
14075
14025
14076
14026
14077
14027

Accuracy class
1
0.5
Art.-no. Art.-no.
14260
14211
14261
14262
14212
14263
14264
14265
14213
14266
14214
14267
14215
14268
14216
14269
14217
14270
14218
14271
14219
14220
14272
14221
14273
14222
14274
14223
14224
14275
14225
14276
14226
14277
14227
14228
14278
14229
14279
14230
14280
14231
14232
14281
14233
14282
14234
14283
14235
14236
14284
14237
14285
14238
14286
14239
14240
14287
14241
14288
14242
14289
14243
14244
14290
14245
14291
14246
14292
14247
14248
14294
14249
14295
14250
14296
14251
14298
14253
14299
14254
14300
14255
14256
14302
14257
14303
14258
14304
14259
14305

14078
14079
14080
14081
14082
14083
14084
14085
14086
14087
14088
14089
14090
14091
14092
14094
14095
14096
14098
14099
14100
14102
14103
14104
14105

14029
14030
14031
14032
14033
14034
14035
14036
14037
14038
14039
14040
14041
14042
14043
14044
14045
14046
14047
14048
14049
14050
14051
14053
14054
14055
14056
14057
14058
14059

www.mbs-stromwandler.de

61

MBS AG

MBS AG

Plug-in current transformers


ASK 541.4

Primary conductor
Round conductor
Transformer width

ASK 51.4
ASK 51.4 2U
ASK 51.4 3U

Primary conductor

ASK 51.6

Primary conductor

Round conductor
Transformer width

40 x 10
2 x 30 x 5
32
86

mm
mm
mm
mm

50 x 12
2 x 40 x 10
44
86

mm
mm
mm
mm

50 x 12
40 x 30
40
95

mm
mm
mm
mm

Round conductor
Transformer width

ASK 561.4

Primary conductor

Round conductor
Transformer width

60 x 10 mm
30 x 40 mm
2 x 50 x 10 mm
44 mm
86 mm

www.mbs-stromwandler.de

63

MBS AG

ASK 541.4
Plug-in current transformer

5A

1A

Accuracy class
1
0.5
0.2s
Art.-no. Art.-no.
Art.-no.

Accuracy class
1
0.5
Art.-no. Art.-no.
15248

Secondary current
Primary
current
A
30
40
50
60
75
80
100

125
150
200

250

300

400

500

600

Primary conductor

40 x 10 mm
2 x 30 x 5 mm
32 mm
86 mm

Art.-no. 59042
see page 205

Round conductor
Transformer width
Snap-on mounting
Sealed shutter
Protection plug-in
current transformer
Current transformer for
tariff applications

64

750

800
1000

see page 140


see page 177

www.mbs-stromwandler.de

Burden
VA
1
1.5
1.5
2.5
1.5
2.5
1.5
2.5
1.5
2.5
1.5
2.5
5
1.5
2.5
5
10
2.5
5
10
2.5
5
10
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
30
2.5
5
10
15
30
2.5
5
10
15
30
10
15
30
2.5
5
10
15
30

15048
15049
15050
15051
15052
15053
15054
15055
15056
15057
15058
15059
15060
15061
15062
15063
15064
15065
15066
15067
15068
15069
15070
15071
15072
15073
15074
15075
15076
15077

15013
15014
15100
15015
15016
15017
15018

15021
15022
15343
15023
15024
15101
15102
15025
15026
15103
15104
15027
15028
15029
15105
15030
15031
15032

15078
15079
15080
15081
15082
15083

15036
15037
15038
15039

15090
15091
15092

15257
15258
V33-1304C
V33-1304D
15259
15260

15019
15020

15033
15034
15035
15344

15084
15085
15086
15087
15088
15089

15249
15250
15251
15252
15253
15254
15255
15256

15040
15041
15042
15043
15044
15106
15045
15046
15047

V33-1604D
V33-1604F
V33-1704D
V33-1704F
V33-1804D
V33-1804F
V33-1804H
V33-1904D
V33-1904F
V33-1904H
V33-2004D
V33-2004F
V33-2004H
V33-2104D
V33-2104F
V33-2104H
V33-2104J
V33-2204D
V33-2204F
V33-2204H
V33-2204J
V33-2304D
V33-2304F
V33-2304H
V33-2304J

V33-2504D
V33-2504F
V33-2504H
V33-2504J

15261
15262
15263
15264
15265
15266
15267
15268
15269
15270
15271
15272
15273
15274
15275
15276
15277
15278
15279
15280

15213
15214
15300
15215
15216
15217
15218
15219
15220
15221
15222
15223
15224
15301
15302
15225
15226
15303
15304
15227
15228
15229
15305
15230
15231
15232
15339
15233
15234
15235

15281
15282
15283

15236
15237
15238
15239

15284
15285
15286
15287
15288
15289

15240
15241
15242
15243
15244
15306

15290
15291
15292

15245
15246
15247

MBS AG

ASK 51.4
Plug-in current transformer
Secondary current
Primary
current
A
100
150
200

250

300

400

500

600

750

800

1000

1200
Primary conductor
Round conductor
Transformer width
Snap-on mounting
Sealed shutter
Protection plug-in
current transformer
Current transformer for
tariff applications

50 x 12 mm
2 x 40 x 10 mm
44 mm
86 mm

Art.-no. 59042
see page 205
see page 142

1250

Burden
VA
1.5
2.5
1.5
2.5
1.5
2.5
5
1.5
2.5
5
10
2.5
5
10
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
5
10
15
30
2.5
5
10
15
30
5
10
15
30
5
10
15
30

5A
Accuracy class
1
0.5
0.2s
Art.-no. Art.-no.
Art.-no.
16043
16170
16086
16171
16044
16011
16045
16010
16012 V34-1704C
16046
16013 V34-1704D
16047
16152 V34-1704F
16014
16048
16015 V34-1804D
16049
16153 V34-1804F
16177
16050
16017 V34-1904D
16051
16018 V34-1904F
16052
16053
16019 V34-2004D
16054
16020 V34-2004F
16055
16021 V34-2004H
16056
16201
16057
16022 V34-2104D
16058
16023 V34-2104F
16059
16024 V34-2104H
16060
16202
16061
16025 V34-2204D
16062
16026 V34-2204F
16063
16027 V34-2204H
16064
16154
16065
16028 V34-2304D
16066
16029 V34-2304F
16067
16030 V34-2304H
16068
16203
16069
16031 V34-2404F
16070
16032 V34-2404H
16071
16033
16072
V34-2504D
16073
16034 V34-2504F
16074
16035 V34-2504H
16075
16036 V34-2504J
16076
16077
16037
16078
16038
16079
16039
16080
16081
16040
16082
16041
16083
16042
16084

1A
Accuracy class
1
0.5
Art.-no. Art.-no.
16243
16244
16245
16246
16247
16248
16249
16390
16250
16251
16252
16253
16254
16255
16256
16257
16258
16259
16260
16261
16262
16263
16264
16265
16266
16267
16268
16269
16270
16271
16272
16273
16274
16275
16276
16277
16278
16279
16280
16281
16282
16283
16284

16211
16210
16212
16213
16352
16214
16215
16353
16217
16218
16219
16220
16221
16222
16223
16224
16225
16226
16227
16354
16228
16229
16230
16231
16232
16233

16234
16235
16236
16237
16238
16239
16240
16241
16242

Change-over transformers see page 66.

see page 178

www.mbs-stromwandler.de

65

MBS AG

ASK 51.4 2U
Plug-in current transformer
Secondary current
Primary
current
A
400-200
500-250
600-300
800-400

1000-500

1200-600

Burden
VA
5-2.5
10-5
5-2.5
10-5
5-2.5
10-5
5-2.5
10-5
15-7.5
5-2.5
10-5
15-7.5
5-2.5
10-5
15-7.5
30-15

5A

1A

Accuracy class
1
Art.-no.
16130
16131
16132
16133
16134
16135
16136
16137
16138
16139
16140
16141
16142
16143
16144
16145

Accuracy class
1
Art.-no.
16330
16331
16332
16333
16334
16335
16336
16337
16338
16339
16340
16341
16342
16343
16344
16345

ASK 51.4 3U
Secondary current
Primary
current
A
800-400-200
1000-500-250
1200-600-300
1200-1000-300
1000-600-400
1000-600-300
600-400-200
1000-800-600
1000-600-300

Primary conductor

50 x 12 mm
2 x 40 x 10 mm
44 mm
86 mm

Art.-no. 59042
see page 205

Round conductor
Transformer width
Snap-on mounting
Sealed shutter
Protection plug-in
current transformer
Current transformer for
tariff applications

66

see page 142


see page 178

www.mbs-stromwandler.de

Burden
VA
10-5-2.5
10-5-2.5
15-7.5-2.5
10-5-2.5
15-7.5-2.5
7.5-5-2.5
10-5-2.5
15-10-5
15-7.5-5
15-10-5
10-5-2.5

5A

1A

Accuracy class
1
Art.-no.
16162
16163
16164
16165
16166
16174
16175
16176
16178
16179
16180

Accuracy class
1
Art.-no.
16362
16363
16364
16365
16366
16374
16375
16376
16378
16379
16380

MBS AG

ASK 51.6
Plug-in current transformer
Secondary current
Primary
current
A
100
150

200

250

300

400

500

600

750

800

1000

Primary conductor
Round conductor
Transformer width
Snap-on mounting
Sealed shutter
Protection plug-in
current transformer
Current transformer for
tariff applications

50 x 12 mm
40 x 30 mm
40 mm
95 mm

Art.-no. 59044
see page 205
see page 144

1200

1250

Burden
VA
2.5
5
2.5
5
10
2.5
5
10
2.5
5
10
15
2.5
5
10
15
30
2.5
5
10
15
30
2.5
5
10
15
30
2.5
5
10
15
30
2.5
5
10
15
30
10
15
30
45
5
10
15
30
45
5
10
15
30
45
5
10
15
30
45

5A

1A

Accuracy class
1
0.5
Art.-no. Art.-no.
17058
17011
17059
17012
17060
17013
17061
17014
17062
17015
17063
17016
17064
17017
17065
17018
17066
17019
17067
17020
17068
17021
17069
17022
17023
17070
17024
17071
17025
17072
17026
17073
17027
17074
17028
17075
17029
17076
17030
17077
17031
17078
17032
17079
17033
17080
17034
17081
17035
17082
17036
17083
17037
17084
17038
17085
17039
17086
17040
17087
17041
17088
17042
17089
17090
17044
17091
17045
17092
17093
17046
17094
17047
17095
17048
17096
17049
17097
17050
17098
17051
17099
17052
17100
17053
17101
17054
17102
17055
17103
17056
17104
17057
17105

Accuracy class
1
0.5
Art.-no. Art.-no.
17258
17211
17259
17212
17260
17213
17261
17214
17262
17215
17263
17216
17264
17217
17265
17218
17266
17219
17267
17220
17268
17221
17269
17222
17223
17270
17224
17271
17225
17272
17226
17273
17227
17274
17228
17275
17229
17276
17230
17277
17231
17278
17232
17279
17233
17280
17234
17281
17235
17282
17236
17283
17237
17284
17238
17285
17239
17286
17240
17287
17241
17288
17242
17289
17290
17244
17291
17245
17292
17293
17246
17294
17247
17295
17248
17296
17249
17297
17250
17298
17251
17299
17252
17300
17253
17301
17254
17302
17255
17303
17256
17304
17257
17305

see page 179

www.mbs-stromwandler.de

67

MBS AG

ASK 561.4
Plug-in current transformer
Secondary current
Primary
current
A
200
250
300
400

500

600

750

800

1000

1200

1250

Primary conductor

Round conductor
Transformer width
Snap-on mounting
Sealed shutter

68

60 x 10 mm
30 x 40 mm
2 x 50 x 10 mm
44 mm
86 mm

Art.-no. 59042
see page 205
www.mbs-stromwandler.de

Burden
VA
2.5
2.5
5
2.5
5
2.5
5
10
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
5
10
15
30
5
10
15
30
5
10
15
30
5
10
15
30

5A

1A

Accuracy class
1
0.5
Art.-no. Art.-no.
18036
18037
18038
18039
18012
18040
18013
18042
18014
18043
18015
18044
18016
18045
18017
18046
18047
18018
18048
18019
18049
18020
18050
18021
18051
18022
18052
18023
18053
18097
18024
18054
18025
18055
18026
18056
18104
18027
18057
18028
18058
18029
18059
18100
18030
18060
18031
18061
18032
18062
18102
18033
18063
18034
18064
18035
18065

Accuracy class
1
0.5
Art.-no. Art.-no.
18236
18237
18238
18239
18212
18240
18213
18242
18214
18243
18215
18244
18216
18245
18217
18246
18247
18218
18248
18219
18249
18220
18250
18221
18251
18222
18252
18223
18253
18224
18254
18225
18255
18226
18256
18227
18257
18228
18258
18229
18259
18267
18230
18260
18231
18261
18232
18262
18233
18263
18234
18264
18235
18265

MBS AG

Plug-in current transformers


ASK 61.4
ASK 61.4 2U
ASK 61.4 3U

Primary conductor

ASK 61.6

Primary conductor

63 x 10
2 x 50 x 10
44
96

mm
mm
mm
mm

60 x 10
50 x 30
40
95

mm
mm
mm
mm

Round conductor
Transformer width

60 x 30
50 x 40
44
96

mm
mm
mm
mm

ASK 63.6

Primary conductor
Round conductor
Transformer width

60 x 30 mm
30 mm
88 mm

ASK 81.4
ASK 81.4 2U
ASK 81.4 3U

Primary conductor

Round conductor
Transformer width

80 x 10 mm
60 x 30 mm
2 x 60 x 10 mm
55 mm
120 mm

ASK 83.4

Primary conductor
Round conductor
Transformer width

84 x 34 mm
34 mm
96 mm

Round conductor
Transformer width

Round conductor
Transformer width

ASK 63.4

Primary conductor

www.mbs-stromwandler.de

69

MBS AG

ASK 61.4
Plug-in current transformer
5A

Secondary current
Primary
current
A
200
250

300

400

500

600

750

800

1000

1200

1250
Primary conductor

63 x 10 mm
2 x 50 x 10 mm
44 mm
96 mm

Art.-no. 59042
see page 205

Round conductor
Transformer width
Snap-on mounting
Sealed shutter
Protection plug-in
current transformer
Current transformer for
tariff applications

70

see page 148


see page 182

www.mbs-stromwandler.de

1500

1600

Burden
VA
1.5
2.5
1.5
2.5
5
1.5
2.5
5
1.5
2.5
5
10
1.5
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
30
2.5
5
10
15
30
5
10
15
30
5
10
15
30
5
10
15
30

1A

Accuracy class
1
0.5
0.2s
Art.-no. Art.-no.
Art.-no.
19047
19009
19048
19010
19049
19011 V41-1804C
19050
19012 V41-1804D
19051
19052
19053
19054
19055
19056
19057
19058
19059
19060
19061
19062
19063
19064
19065
19066
19067
19068
19069
19070
19071
19072
19073

19013
19014
19015
19016
19017
19018
19094
19019
19020
19021
19095
19096
19022
19023
19024
19097
19025
19026
19027
19098
19028
19029
19030
19031

19074
19075
19076
19077

19032
19033
19034
19099

19078
19079
19080
19081
19082
19083
19084
19085
19086
19087
19088
19089
19090
19091
19092
19093

19035
19036
19037
19100
19038
19039
19040
19101
19041
19042
19043
19102
19044
19045
19046
19103

V41-1904D
V41-1904F
V41-2004D
V41-2004F
V41-2004H
V41-2104D
V41-2104F
V41-2104H
V41-2204D
V41-2204F
V41-2204H
V41-2204J
V41-2304D
V41-2304F
V41-2304H
V41-2304J

V41-2504D
V41-2504F
V41-2504H
V41-2504J
V41-2604D
V41-2604F
V41-2604H
V41-2604J
V41-2704F
V41-2704H
V41-2704J
V41-2804F
V41-2804H
V41-2804J

Accuracy class
1
0.5
Art.-no. Art.-no.
19247
19209
19248
19210
19249
19211
19250
19212
19175
19251
19213
19252
19214
19253
19215
19254
19216
19255
19217
19256
19218
19257
19294
19219
19258
19220
19259
19221
19260
19295
19261
19296
19262
19222
19263
19223
19264
19224
19265
19297
19266
19225
19267
19226
19268
19227
19269
19298
19270
19228
19271
19229
19272
19230
19273
19231
19274
19275
19276
19277

19232
19233
19234
19299

19278
19279
19280
19281
19282
19283
19284
19285
19286
19287
19288
19289
19290
19291
19292
19293

19235
19236
19237
19300
19238
19239
19240
19301
19241
19242
19243
19302
19244
19245
19246
19303

MBS AG

ASK 61.4 2U
Plug-in current transformer
Secondary current
Primary
current
A
500-250
600-300
800-400

1000-500

1200-600

1500-750

1600-800

Burden
VA
5-2.5
5-2.5
10-5
5-2.5
10-5
15-7.5
5-2.5
10-5
15-7.5
5-2.5
10-5
15-7.5
5-2.5
10-5
15-7.5
30-15
5-2.5
10-7.5
15-7.5
30-15

5A

1A

Accuracy class
1
Art.-no.
19141
19142
19143
19144
19145
19146
19147
19148
19149
19150
19151
19152
19153
19154
19155
19156
19157
19158
19159
19160

Accuracy class
1
Art.-no.
19341
19342
19343
19344
19345
19346
19347
19348
19349
19350
19351
19352
19353
19354
19355
19356
19357
19358
19359
19360

ASK 61.4 3U
Secondary current
Primary
current
A
800-400-200
1000-500-250
1000-600-300
1200-600-300
1500-750-400
1600-800-400
1000-600-400
Primary conductor
Round conductor
Transformer width
Snap-on mounting
Sealed shutter
Protection plug-in
current transformers

Burden
VA
10-5-2.5
10-5-2.5
15-7.5-2.5
10-5-2.5
15-7.5-2.5
10-5-2.5
15-7.5-2.5
10-5-2.5
15-7.5-2.5
10-5-2.5
15-7.5-2.5
10-5-2.5

5A

1A

Accuracy class
1
Art.-no.
19182
19183
19184
19185
19186
19187
19188
19189
19190
19191
19192
19199

Accuracy class
1
Art.-no.
19382
19383
19384
19385
19386
19387
19388
19389
19390
19391
19392
19399

63 x 10 mm
2 x 50 x 10 mm
44 mm
96 mm

Art.-no. 59042
see page 205
see page 148

www.mbs-stromwandler.de

71

MBS AG

ASK 61.6
Plug-in current transformer

Secondary current
Primary
current
A
100
150
200
250

300

400

500

600

750

800

1000

1200

1250

Primary conductor

60 x 10 mm
50 x 30 mm
40 mm
95 mm

Art.-no. 59044
see page 205

Round conductor
Transformer width
Snap-on mounting
Sealed shutter
Current transformer for
tariff applications

72

see page 183

www.mbs-stromwandler.de

1500

1600

Burden
VA
1.5
2.5
1.5
2.5
2.5
5
10
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
30
2.5
5
10
15
30
2.5
5
10
15
30
2.5
5
10
15
30
5
10
15
30
5
10
15
30
45
5
10
15
30
45
5
10
15
30
45
5
10
15
30
45
10
15
30
45

5A

1A

Accuracy class
1
0.5
Art.-no. Art.-no.
20063
20011
20064
20065
20012
20066
20013
20067
20014
20068
20015
20069
20116
20016
20070
20017
20071
20018
20072
20117
20019
20073
20020
20074
20021
20075
20022
20118
20023
20076
20024
20077
20025
20078
20026
20079
20119
20027
20080
20028
20081
20029
20082
20030
20083
20120
20031
20084
20032
20085
20033
20086
20034
20087
20121
20035
20088
20036
20089
20037
20090
20038
20091
20092
20040
20093
20041
20094
20042
20095
20122
20043
20096
20044
20097
20045
20098
20046
20099
20123
20047
20100
20048
20101
20049
20102
20050
20103
20124
20051
20104
20052
20105
20053
20106
20054
20107
20125
20055
20108
20056
20109
20057
20110
20058
20111
20112
20060
20113
20061
20114
20062
20115

Accuracy class
1
0.5
Art.-no. Art.-no.
20263
20211
20264
20265
20212
20266
20213
20267
20214
20268
20215
20269
20321
20216
20270
20217
20271
20218
20272
20322
20219
20273
20220
20274
20221
20275
20222
20323
20223
20276
20224
20277
20225
20278
20226
20279
20324
20227
20280
20228
20281
20229
20282
20230
20283
20325
20231
20284
20232
20285
20233
20286
20234
20287
20326
20235
20288
20236
20289
20237
20290
20238
20291
20292
20240
20293
20241
20294
20242
20295
20327
20243
20296
20244
20297
20245
20298
20246
20299
20328
20247
20300
20248
20301
20249
20302
20250
20303
20329
20251
20304
20252
20305
20253
20306
20254
20307
20330
20255
20308
20256
20309
20257
20310
20258
20311
20312
20260
20313
20261
20314
20262
20315

MBS AG

ASK 63.4
Plug-in current transformer
Secondary current
Primary
current
A
300
400
500
600

750

800

1000

1200

1250

1500

1600

1800

2000

Primary conductor
Round conductor
Transformer width
Snap-on mounting
Sealed shutter

Burden
VA
1.5
2.5
2.5
5
5
10
5
10
15
5
10
15
5
10
15
5
10
15
5
10
15
5
10
15
5
10
15
5
10
15
5
10
15
5
10
15

5A

1A

Accuracy class
1
0.5
Art.-no. Art.-no.
25041
25011
25042
25012
25043
25013
25044
25014
25045
25015
25046
25047
25017
25048
25018
25049
25050
25020
25051
25021
25052
25022
25053
25023
25054
25024
25055
25025
25056
25026
25057
25027
25058
25028
25059
25029
25060
25030
25061
25031
25062
25032
25063
25033
25064
25034
25065
25035
25066
25036
25067
25037
25068
25038
25069
25039
25070
25040
25078
25071
25079
25072
25080
25073
25081
25074
25082
25076
25083
25077

Accuracy class
1
0.5
Art.-no. Art.-no.
25241
25211
25242
25212
25243
25213
25244
25214
25245
25215
25246
25247
25217
25248
25218
25249
25250
25220
25251
25221
25252
25222
25253
25223
25254
25224
25255
25225
25256
25226
25257
25227
25258
25228
25259
25229
25260
25230
25261
25231
25262
25232
25263
25233
25264
25234
25265
25235
25266
25236
25267
25237
25268
25238
25269
25239
25270
25240
25278
25271
25279
25272
25280
25273
25281
25274
25282
25276
25283
25277

60 x 30 mm
50 x 40 mm
44 mm
96 mm

Art.-no. 59042
see page 205

www.mbs-stromwandler.de

73

MBS AG

ASK 63.6
Plug-in current transformer
Secondary current
Primary
current
A
200
250

300

400

500

600

750

800

1000

1200

1250

1500
Primary conductor
Round conductor
Transformer width
Snap-on mounting
Sealed shutter
Protection plug-in
current transformer
Current transformer for
tariff applications

74

60 x 30 mm
30 mm
88 mm

Art.-no. 59042
see page 205

1600

see page 152

2000

see page 184

www.mbs-stromwandler.de

Burden
VA
1.5
2.5
1.5
2.5
5
1.5
2.5
5
10
2.5
5
10
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
30
2.5
5
10
15
5
10
15
30
5
10
15
30
5
10
15
30
5
10
15
30
5
10
15
30
5
10
15
30

5A

1A

Accuracy class
1
0.5
Art.-no. Art.-no.
85060
85061
85062
85011
85063
85012

Accuracy class
1
0.5
Art.-no. Art.-no.
85260
85261
85262
85211
85263
85212

85064
85065
85066
85067
85068
85069
85071
85073
85074
85075
85076
85077
85078
85079
85080
85081
85082
85083
85084

85013
85014
85015

85085
85086
85087
85088
85089
85090
85091
85092
85093
85094
85095
85096
85097
85098
85099
85100
85101
85102
85103
85104
85105
85106
85107
85108
85109
85110
85111
85112

85033
85034
85035
85036
85037
85038
85039

85017
85018
85021
85022

85025
85026
85027
85029
85030
85031

85041
85042
85043
85044
85045
85046
85047
85049
85050
85051
85053
85054
85055
85056
85057
85058
85059

85264
85265
85266
85267
85268
85269

85213
85214
85215

85273
85274
85275
85276
85277
85278
85279
85280
85281
85282
85283
85284

85221
85222

85285
85286
85287
85288
85289
85290
85291
85292
85293
85294
85295
85296
85297
85298
85299
85300
85301
85302
85303
85304
85305
85306
85307
85308
85309
85310
85311
85312

85233
85234
85235
85236
85237
85238
85239

85217
85218

85225
85226
85227
85229
85230
85231

85241
85242
85243
85244
85245
85246
85247
85249
85250
85251
85253
85254
85255
85256
85257
85258
85259

MBS AG

ASK 81.4
Plug-in current transformer
Secondary current
Primary
current
A
400

500

600

750

800

1000

1200

1250

1500

1600

2000
Primary conductor

Round conductor
Transformer width
Snap-on mounting
Sealed shutter
Current transformer for
tariff applications

80 x 10 mm
60 x 30 mm
2 x 60 x 10 mm
55 mm
120 mm

Art.-no. 59042
see page 205

Burden
VA
2.5
5
10
2.5
5
10
2.5
5
10
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
30
5
10
15
30
5
10
15
30
5
10
15
30
45
5
10
15
30
45
10
15
30
45

5A
Accuracy class
1
0.5
0.2s
Art.-no. Art.-no.
Art.-no.
21038
21009 V47-2004D
21039
21010 V47-2004F
21197
21040
21011 V47-2104D
21041
21135 V47-2104F
21042
21078
21043
21012 V47-2204D
21044
21013 V47-2204F
21045
21014 V47-2204H
21046
21015 V47-2304D
21047
21016 V47-2304F
21048
21017 V47-2304H
21049
21079
21050
21018
21051
21019
21052
21020
21053
21080
21084
V47-2504D
21054
21021 V47-2504F
21055
21022 V47-2504H
21056
21023 V47-2504J
21057
21058
21024 V47-2604F
21059
21025 V47-2604H
21060
21026 V47-2604J
21061
21062
21027 V47-2704F
21063
21028 V47-2704H
21064
21029 V47-2704J
21065
21085
21030 V47-2804F
21066
21031 V47-2804H
21067
21032 V47-2804J
21068
21069
21086
21033
21070
21034
21071
21035
21072
21073
21074
21036
21075
21037
21076
21077

1A
Accuracy class
1
0.5
Art.-no. Art.-no.
21238
21209
21239
21210
21240
21241
21242
21243
21244
21245
21246
21247
21248
21249
21250
21251
21252
21253

21211
21335
21278
21212
21213
21214
21215
21216
21217
21279
21218
21219
21220
21280

21254
21255
21256
21257
21258
21259
21260
21261
21262
21263
21264
21265

21221
21222
21223

21266
21267
21268
21269
21270
21271
21272
21273
21274
21275
21276
21277

21224
21225
21226
21227
21228
21229
21230
21231
21232

21233
21234
21235

21236
21237

Change-over transformers see page 76.

see page 185


www.mbs-stromwandler.de

75

MBS AG

ASK 81.4 2U
Plug-in current transformer
Secondary current
Primary
current
A
1000-500
1200-600
1500-750

1600-800

2000-1000

Burden
VA
10-5
15-7.5
10-5
15-7.5
10-5
15-7.5
30-15
10-5
15-7.5
30-15
10-5
15-7.5
30-15

5A

1A

Accuracy class
1
Art.-no.
21120
21121
21122
21123
21124
21125
21126
21127
21128
21129
21130
21131
21132

Accuracy class
1
Art.-no.
21320
21321
21322
21323
21324
21325
21326
21327
21328
21329
21330
21331
21332

ASK 81.4 3U
Secondary current
Primary
current
A
2000-1500-1000
2000-1000-500
1600-800-400
1500-1000-500
1200-800-600
1500-1000-750
1000-750-500

Primary conductor

Round conductor
Transformer width
Snap-on mounting
Sealed shutter

76

80 x 10 mm
60 x 30 mm
2 x 60 x 10 mm
55 mm
120 mm

Art.-no. 59042
see page 205
www.mbs-stromwandler.de

Burden
VA
30-15-10
30-10-5
15-10-5
15-10-5
15-10-5
15-10-5
10-5-2.5

5A

1A

Accuracy class
1
Art.-no.
21160
21161
21162
21163
21164
21165
21166

Accuracy class
1
Art.-no.
21360
21361
21362
21363
21364
21365
21366

MBS AG

MBS AG

ASK 83.4
Plug-in current transformer
Secondary current
Primary
current
A
300
400
500
600

750

800

1000

1200

1250

1500

1600

1800

2000

2500

Burden
VA
1.5
2.5
2.5
5
2.5
5
2.5
5
10
2.5
5
10
15
2.5
5
10
15
5
10
15
5
10
15
5
10
15
5
10
15
5
10
15
30
10
15
30
10
15
30
10
15
30

5A

1A

Accuracy class
1
0.5
Art.-no.
Art.-no.
100051-x 100011-x
100052-x 100012-x
100053-x 100013-x
100054-x 100014-x
100055-x 100015-x
100056-x 100016-x
100057-x 100017-x
100058-x 100018-x
100059-x
100060-x 100019-x
100061-x 100020-x
100062-x 100021-x
100063-x
100064-x 100022-x
100065-x 100023-x
100066-x 100024-x
100067-x
100068-x 100025-x
100069-x 100026-x
100070-x 100027-x
100071-x 100028-x
100072-x 100029-x
100073-x 100030-x
100074-x 100031-x
100075-x 100032-x
100076-x 100033-x
100077-x 100034-x
100078-x 100035-x
100079-x 100036-x
100080-x 100037-x
100081-x 100038-x
100082-x 100039-x
100083-x
100084-x 100040-x
100085-x 100041-x
100086-x
100087-x 100042-x
100088-x 100043-x
100089-x
100090-x 100044-x
100091-x 100045-x
100092-x

Accuracy class
1
0.5
Art.-no.
Art.-no.
100251-x 100211-x
100252-x 100212-x
100253-x 100213-x
100254-x 100214-x
100255-x 100215-x
100256-x 100216-x
100257-x 100217-x
100258-x 100218-x
100259-x
100260-x 100219-x
100261-x 100220-x
100262-x 100221-x
100263-x
100264-x 100222-x
100265-x 100223-x
100266-x 100224-x
100267-x
100268-x 100225-x
100269-x 100226-x
100270-x 100227-x
100271-x 100228-x
100272-x 100229-x
100273-x 100230-x
100274-x 100231-x
100275-x 100232-x
100276-x 100233-x
100277-x 100234-x
100278-x 100235-x
100279-x 100236-x
100280-x 100237-x
100281-x 100238-x
100282-x 100239-x
100283-x
100284-x 100240-x
100285-x 100241-x
100286-x
100287-x 100242-x
100288-x 100243-x
100289-x
100290-x 100244-x
100291-x 100245-x
100292-x

Connection options see page 79.

Primary conductor
Round conductor
Transformer width

78

84 x 34 mm
34 mm
96 mm
www.mbs-stromwandler.de

MBS AG

ASK 83.4
Plug-in current transformer

Connection options
The plug-in current transformer ASK 83.4 is a multipurpose transformer
which can be installed vertically or horizontally. There are 6 connection options
to choose from.

connection
-2
standard

connection
-1

connection
-5

connection
-3

housing bottom (h.b.)

connection
-6

connection
-4

housing top (h.t.)

Order example
ASK 83.4

800/5

10/1

Connection option K-P1 (h.b.) top


Art.-no.

100066-2

www.mbs-stromwandler.de

79

MBS AG

MBS AG

Plug-in current transformers


ASK 101.4
ASK 101.4 2U

Primary conductor

ASK 103.3

Primary conductor

Round conductor
Transformer width

Round conductor
Transformer width

100 x 10
2 x 80 x 10
70
130

mm
mm
mm
mm

2 x 100 x 10
3 x 80 x 10
85
172

mm
mm
mm
mm

ASK 103.41
ASK 103.41 2U

Primary conductor
Round conductor
Transformer width

103 x 41 mm
40 mm
99 mm

ASK 105.6

Primary conductor
Round conductor
Transformer width

100 x 55 mm
55 mm
129 mm

ASK 105.6N

Primary conductor
Round conductor
Transformer width

100 x 55 mm
55 mm
129 mm

ASK 123.3

Primary conductor
Round conductor
Transformer width

123 x 30
3 x 100 x 10
100
172

mm
mm
mm
mm

ASK 127.4

Primary conductor
Round conductor
Transformer width

120 x 70 mm
70 mm
159 mm

ASK 127.6

Primary conductor
Round conductor
Transformer width

120 x 72 mm
72 mm
205 mm

www.mbs-stromwandler.de

81

MBS AG

ASK 101.4
Plug-in current transformer
Secondary current
Primary
current
A
500

600

750

800

1000

1200

1250

1500

1600

1800

2000

2500
Primary conductor
Round conductor
Transformer width
Snap-on mounting
Sealed shutter

82

100 x 10 mm
2 x 80 x 10 mm
70 mm
130 mm

Art.-no. 59042
see page 205
www.mbs-stromwandler.de

Burden
VA
2.5
5
10
2.5
5
10
2.5
5
10
5
10
15
5
10
15
30
5
10
15
30
5
10
15
30
5
10
15
30
5
10
15
30
45
5
10
15
30
45
5
10
15
30
45
5
10
15
30
45

5A

1A

Accuracy class
1
0.5
Art.-no. Art.-no.
22009
22076
22010
22077
22011
22038
22012
22039
22239
22013
22040
22014
22041
22078
22042
22015
22043
22016
22044
22045
22017
22046
22018
22047
22115
22048
22019
22049
22020
22050
22051
22052
22021
22053
22022
22054
22055
22056
22023
22057
22024
22058
22025
22059
22026
22060
22027
22061
22028
22062
22063
22029
22064
22030
22065
22031
22066
22067
22032
22068
22033
22069
22034
22070
22118
22071
22035
22072
22036
22073
22037
22074
22119
22075

Accuracy class
1
0.5
Art.-no. Art.-no.
22209
22276
22210
22277
22211
22238
22212

22240
22241
22242
22243
22244
22245
22246
22247
22278
22248
22249
22250
22251
22252
22253
22254
22255
22256
22257
22258
22259
22260
22261
22262
22263
22264
22265
22266
22267
22268
22269
22270
22271
22272
22273
22274
22275

22213
22214
22281
22215
22216
22217
22218

22219
22220

22221
22222

22223
22224
22279
22226
22227
22228

22229
22230
22231

22232
22233
22234
22280
22235
22236
22237
22337

MBS AG

ASK 101.4 2U
Plug-in current transformer
Secondary current
Primary
current
A
1200-600
1500-750
1600-800

2000-1000

2500-1250

Primary conductor
Round conductor
Transformer width
Snap-on mounting
Sealed shutter

Burden
VA
10-5
15-7.5
10-5
15-7.5
10-5
15-7.5
30-15
10-5
15-7.5
30-15
10-5
15-7.5
30-15

5A

1A

Accuracy class
1
Art.-no.
22120
22121
22122
22123
22124
22125
22126
22127
22128
22129
22130
22131
22132

Accuracy class
1
Art.-no.
22320
22321
22322
22323
22324
22325
22326
22327
22328
22329
22330
22331
22332

100 x 10 mm
2 x 80 x 10 mm
70 mm
130 mm

Art.-no. 59042
see page 205
www.mbs-stromwandler.de

83

MBS AG

ASK 103.3
Plug-in current transformer
Secondary current
Primary
current
A
750

800

1000

1200

1250

1500

1600

2000

2500

3000

Primary conductor
Round conductor
Transformer width
Snap-on mounting
Sealed shutter
2 pieces

84

2 x 100 x 10 mm
3 x 80 x 10 mm
85 mm
172 mm

Art.-no. 59040
see page 205
www.mbs-stromwandler.de

Burden
VA
2.5
5
10
2.5
5
10
15
5
10
15
5
10
15
30
5
10
15
30
10
15
30
45
10
15
30
45
10
15
30
45
10
15
30
45
10
15
30
45

5A

1A

Accuracy class
1
0.5
Art.-no. Art.-no.
23011
23036
23037
23012
23038
23013
23039
23040
23041
23014
23042
23015
23043
23016
23044
23017
23045
23018
23046
23019
23047
23048
23020
23049
23021
23050
23022
23051
23052
23023
23053
23024
23054
23055
23056
23025
23057
23026
23058
23059
23060
23027
23061
23028
23062
23029
23063
23064
23030
23065
23031
23066
23032
23067
23068
23033
23069
23034
23070
23035
23071

Accuracy class
1
0.5
Art.-no. Art.-no.
23211
23236
23237
23212
23238
23213
23239
23240
23241
23214
23242
23215
23243
23216
23244
23217
23245
23218
23246
23219
23247
23248
23220
23249
23221
23250
23222
23251
23252
23223
23253
23224
23254
23255
23256
23225
23257
23226
23258
23259
23260
23227
23261
23228
23262
23229
23263
23264
23230
23265
23231
23266
23232
23267
23268
23233
23269
23234
23270
23235
23271

MBS AG

ASK 103.41
Plug-in current transformer
Secondary current
Primary
current
A
400
500
600
750
800
1000
1200
1250
1500
2000

Burden
VA
2.5
5
2.5
5
2.5
5
2.5
5
5
10
10
15
10
15
10
15
15
30
15
30

5A

1A

Accuracy class
1
0.5
Art.-no. Art.-no.
97051
97021
97052
97053
97023
97054
97055
97025
97056
97057
97027
97058
97059
97029
97060
97061
97031
97062
97063
97033
97064
97065
97035
97066
97067
97037
97068
97069
97039
97070

Accuracy class
1
0.5
Art.-no. Art.-no.
97251
97221
97252
97253
97223
97254
97255
97225
97256
97257
97227
97258
97259
97229
97260
97261
97231
97262
97263
97233
97264
97265
97235
97266
97267
97237
97268
97269
97239
97270

ASK 103.41 2U
Secondary current
Primary
current
A
1000-500
1200-600
1500-750
2000-1000

Primary conductor
Round conductor
Transformer width
Snap-on mounting
Sealed shutter

Burden
VA
5-2.5
5-2.5
10-5
15-7.5
15-7.5
30-15

5A

1A

Accuracy class
1
0.5
Art.-no. Art.-no.
97081
97071
97082
97072
97083
97073
97084
97085
97075
97086

Accuracy class
1
0.5
Art.-no. Art.-no.
97281
97271
97282
97272
97283
97273
97284
97285
97275
97286

103 x 41 mm
40 mm
99 mm

www.mbs-stromwandler.de

85

MBS AG

ASK 105.6
Plug-in current transformer
Secondary current
Primary
current
A
600

750

800
1000

1200

1250

1500

1600

1800

2000

2400

2500
Primary conductor
Round conductor
Transformer width
Snap-on mounting
Sealed shutter

100 x 55 mm
55 mm
129 mm

Art.-no. 59042
see page 205

Protection plug-in
current transformer
Current transformer for
tariff applications

86

see page 153


see page 188

www.mbs-stromwandler.de

3000

Burden
VA
2.5
5
10
2.5
5
10
5
10
2.5
5
10
15
5
10
15
5
10
15
30
5
10
15
30
5
10
15
30
5
10
15
30
5
10
15
30
45
5
10
15
30
5
10
15
30
45
5
10
15
30
45

5A
Accuracy class
1
0.5
0.2s
Art.-no. Art.-no.
Art.-no.
86083 V55-2204D
86092
86084
86093
86086 V55-2304D
86095
86087 V55-2304F
86096
86157
86097
86089 V55-2404F
86098
86090 V55-2404H
86158 V55-2504D
86051
86011 V55-2504F
86052
86159 V55-2504H
86160
86053
86013 V55-2604F
86054
86014 V55-2604H
86055
86015
86056
86016 V55-2704F
86057
86017 V55-2704H
86058
86018 V55-2704J
86162
86059
86019 V55-2804F
86060
86020 V55-2804H
86061
86021 V55-2804J
86062
86163
86110
86164 V55-2904F
86142
86165 V55-2904H
86101
86149 V55-2904J
86138
86166
86063
86023
86064
86024
86065
86025
86066
86167 V55-3004F
86067
86027 V55-3004H
86068
86028 V55-3004J
86069
86029
86070
86168 V55-3104F
86169 V55-3104H
86170 V55-3104J
86171
86172 V55-3204F
86071
86031 V55-3204H
86072
86032 V55-3204J
86073
86033
86074
86173 V55-3304F
86075
86035 V55-3304H
86076
86036 V55-3304J
86077
86037
86078

1A
Accuracy class
1
0.5
Art.-no. Art.-no.
86283
86292
86284
86293
86286
86295
86287
86296
86297
86289
86298
86290
86251
86252
86299
86253
86254
86255
86256
86257
86258

86211

86213
86214
86215
86216
86217
86218

86259
86260
86261
86262

86219
86220
86221

86331
86330
86337
86263
86264
86265
86266

86338
86339
86340
86223
86224
86225

86267
86268
86269
86270

86227
86228
86229

86271
86272
86273
86274

86231
86232
86233

86275
86276
86277
86278

86235
86236
86237

MBS AG

ASK 105.6 N
Plug-in current transformer
Secondary current
Primary
current
A
2500

3000

4000

5000

Primary conductor
Round conductor
Transformer width
Snap-on mounting
Sealed shutter

Burden
VA
10
15
30
45
10
15
30
45
10
15
30
45
10
15
30
45

5A

1A

Accuracy class
1
0.5
Art.-no. Art.-no.
86451
86481
86452
86482
86453
86483
86454
86455
86484
86456
86485
86457
86486
86458
86459
86487
86460
86488
86461
86489
86462
86463
86490
86464
86491
86465
86492
86466

Accuracy class
1
0.5
Art.-no. Art.-no.
86411
86431
86412
86432
86413
86433
86414
86415
86434
86416
86435
86417
86436
86418
86419
86437
86420
86438
86421
86439
86422
86423
86440
86424
86441
86425
86442
86426

100 x 55 mm
55 mm
129 mm

Art.-no. 59042
see page 205

www.mbs-stromwandler.de

87

MBS AG

ASK 123.3
Plug-in current transformer
Secondary current
Primary
current
A
750

1000

1200

1250

1500

1600

1800

2000

2500

3000

4000

Primary conductor
Round conductor
Transformer width
Snap-on mounting
Sealed shutter
2 pieces
Tariff current transformer
tariff applications

88

123 x 30 mm
3 x 100 x 10 mm
100 mm
172 mm

Art.-no. 59040
see page 205
see page 189

www.mbs-stromwandler.de

Burden
VA
2.5
5
10
2.5
5
10
5
10
15
5
10
15
5
10
15
30
5
10
15
30
5
10
15
30
5
10
15
30
45
5
10
15
30
45
5
10
15
30
45
10
15
30
45

5A
Accuracy class
1
0.5
0.2s
Art.-no. Art.-no.
Art.-no.
24127
24128
24129
24010 V56-2504D
24037
24011 V56-2504F
24038
24126
24039
24012 V56-2604F
24040
24013
24041
24014
24042
24015 V56-2704F
24043
24016 V56-2704H
24044
24017
24045
24018 V56-2804F
24046
24019 V56-2804H
24047
24020
24048
24130
24112
V56-2904F
24107
V56-2904H
24113
V56-2904J
24108
24131
24049
24021
24050
24022
24051
24023
24052
24024 V56-3004F
24053
24025 V56-3004H
24054
24026 V56-3004J
24055
24027
24056
24136 V56-3204F
24057
24028 V56-3204H
24058
24029 V56-3204J
24059
24030
24060
24137 V56-3304F
24061
24031 V56-3304H
24062
24032 V56-3304J
24063
24033
24064
24065
24034
24066
24035
24067
24036
24068

1A
Accuracy class
1
0.5
Art.-no. Art.-no.

24237
24238
24239
24240
24241
24242
24243
24244
24245
24246
24247
24248

24211
24125
24212
24213
24214
24215
24216
24217
24218
24219
24220

24249
24250
24251
24252

24221
24222
24223

24253
24254
24255
24256

24224
24225
24226
24227

24257
24258
24259
24260

24228
24229
24230

24261
24262
24263
24264
24265
24266
24267
24268

24231
24232
24233
24234
24235
24236

MBS AG

ASK 127.4
Plug-in current transformer
Secondary current
Primary
current
A
1000
1200

1250

1500

1600

1800

2000

2500

Primary conductor
Round conductor
Transformer width
Snap-on mounting
Sealed shutter

Burden
VA
5
10
5
10
15
10
15
30
10
15
30
10
15
30
10
15
30
10
15
30
45
10
15
30
45

5A

1A

Accuracy class
1
0.5
Art.-no. Art.-no.
87540
87510
87541
87511
87542
87512
87543
87513
87544
87514
87545
87515
87546
87516
87547
87517
87548
87518
87549
87519
87550
87520
87551
87521
87552
87522
87553
87523
87554
87524
87555
87525
87556
87526
87557
87527
87558
87528
87559
87529
87560
87530
87561
87531
87562
87532
87563
87533
87564
87534

Accuracy class
1
0.5
Art.-no. Art.-no.
87640
87610
87641
87611
87642
87612
87643
87613
87644
87614
87645
87615
87646
87616
87647
87617
87648
87618
87649
87619
87650
87620
87651
87621
87652
87622
87653
87623
87654
87624
87655
87625
87656
87626
87657
87627
87658
87628
87659
87629
87660
87630
87661
87631
87662
87632
87663
87633
87664
87634

120 x 70 mm
70 mm
159 mm

Art.-no. 59042
see page 205
www.mbs-stromwandler.de

89

MBS AG

ASK 127.6
Plug-in current transformer
Secondary current
Primary
current
A
1000
1200

1250

1500

1800

2000

2500

3000

4000

5000

6000

Primary conductor
Round conductor
Transformer width
Snap-on mounting
Sealed shutter

90

120 x 70 mm
70 mm
159 mm

Art.-no. 59042
see page 205

www.mbs-stromwandler.de

Burden
VA
5
10
5
10
15
5
10
15
30
5
10
15
30
5
10
15
30
10
15
30
45
10
15
30
45
10
15
30
45
10
15
30
45
10
15
30
45
10
15
30
45

5A

1A

Accuracy class
1
0.5
Art.-no. Art.-no.
87055
87011
87056
87057
87013
87058
87014
87059
87060
87016
87061
87017
87062
87018
87063
87019
87064
87020
87065
87021
87066
87022
87067
87023
87068
87024
87069
87025
87070
87026
87071
87027
87072
87028
87073
87029
87074
87030
87075
87076
87032
87077
87033
87078
87034
87079
87081
87036
87082
87037
87083
87038
87084
87085
87040
87086
87041
87087
87042
87088
87089
87044
87090
87045
87091
87046
87092
87093
87048
87094
87049
87095
87050
87096

Accuracy class
1
0.5
Art.-no. Art.-no.
87255
87211
87256
87257
87213
87258
87214
87259
87260
87216
87261
87217
87262
87218
87263
87219
87264
87220
87265
87221
87266
87222
87267
87223
87268
87224
87269
87225
87270
87226
87271
87227
87272
87228
87273
87229
87274
87230
87275
87276
87232
87277
87233
87278
87234
87279
87281
87236
87282
87237
87283
87238
87284
87285
87240
87286
87241
87287
87242
87288
87289
87244
87290
87245
87291
87246
87292
87293
87248
87294
87249
87295
87250
87296

MBS AG

Plug-in current transformers


ASK 128.4

Primary conductor
Round conductor
Transformer width

128 x 38 mm
38 mm
100 mm

ASK 129.10

Primary conductor
Round conductor
Transformer width

120 x 90 mm
90 mm
250 mm

ASK 130.3

Primary conductor
Round conductor
Transformer width

130 x 25 mm
25 mm
180 mm

ASK 130.5

Primary conductor
Round conductor
Transformer width

130 x 30 mm
30 mm
180 mm

www.mbs-stromwandler.de

91

MBS AG

ASK 128.4
Plug-in current transformer
Secondary current
Primary
current
A
400
500
600
750
800
1000
1200
1250
1500
2000
2500

Primary conductor
Round conductor
Transformer width
Snap-on mounting
Sealed shutter

92

128 x 38 mm
38 mm
100 mm

Art.-no. 59042
see page 205

www.mbs-stromwandler.de

Burden
VA
2.5
5
2.5
5
2.5
5
2.5
5
5
10
10
15
10
15
10
15
15
30
15
30
15
30

5A

1A

Accuracy class
1
0.5
Art.-no. Art.-no.
94041
94011
94042
94043
94013
94044
94045
94015
94046
94047
94017
94048
94049
94019
94050
94051
94021
94052
94053
94023
94054
94055
94025
94056
94057
94027
94058
94059
94029
94060
94061
94031
94062

Accuracy class
1
0.5
Art.-no. Art.-no.
94241
94211
94242
94243
94213
94244
94245
94215
94246
94247
94217
94248
94249
94219
94250
94251
94221
94252
94253
94223
94254
94255
94225
94256
94257
94227
94258
94259
94229
94260
94261
94231
94262

MBS AG

ASK 129.10
Plug-in current transformer
Secondary current
Primary
current
A
1000

1200

1250

1500

1600

1800

2000

2500

3000

4000

5000

6000

7500

Primary conductor
Round conductor
Transformer width
Snap-on mounting
Sealed shutter

Burden
VA
5
10
15
5
10
15
5
10
15
10
15
30
10
15
30
10
15
30
10
15
30
15
30
45
15
30
45
15
30
45
15
30
45
15
30
45
15
30
45

5A

1A

Accuracy class
1
0.5
Art.-no. Art.-no.
88070
88011
88071
88072
88073
88014
88074
88015
88075
88076
88017
88077
88018
88078
88079
88020
88080
88021
88081
88022
88082
88023
88083
88024
88084
88025
88085
88026
88086
88027
88087
88028
88088
88029
88089
88030
88090
88031
88091
88032
88092
88033
88093
88034
88094
88035
88095
88036
88096
88037
88097
88038
88098
88039
88099
88040
88100
88041
88101
88042
88102
88043
88103
88044
88104
88045
88105
88046
88106
88047
88107
88048
88108
88049

Accuracy class
1
0.5
Art.-no. Art.-no.
88270
88211
88271
88272
88273
88214
88274
88215
88275
88276
88217
88277
88218
88278
88279
88220
88280
88221
88281
88222
88282
88223
88283
88224
88284
88225
88285
88226
88286
88227
88287
88228
88288
88229
88289
88230
88290
88231
88291
88232
88292
88233
88293
88234
88294
88235
88295
88236
88296
88237
88297
88238
88298
88239
88299
88240
88300
88241
88301
88242
88302
88243
88303
88244
88304
88245
88305
88246
88306
88247
88307
88248
88308
88249

120 x 90 mm
90 mm
250 mm

Art.-no. 59042
see page 205

www.mbs-stromwandler.de

93

MBS AG

ASK 130.3
Plug-in current transformer
Secondary current
Primary
current
A
300
400

500

600

750

1000

1200

1250

1500

1600

Primary conductor
Round conductor
Transformer width
Snap-on mounting
Sealed shutter
Current transformer for
tariff applications

94

130 x 25 mm
25 mm
180 mm

see page 190

www.mbs-stromwandler.de

Burden
VA
2.5
5
2.5
5
10
2.5
5
10
2.5
5
10
15
2.5
5
10
15
5
10
15
30
5
10
15
30
5
10
15
30
5
10
15
30
5
10
15
30

5A

1A

Accuracy class
1
0.5
0.2s
Art.-no. Art.-no.
Art.-no.
I50-1900D I50-1901D
I50-1900F I50-1901F
I50-2000D I50-2001D
I50-2000F I50-2001F
I50-2000H I50-2001H
I50-2100D I50-2101D
I50-2100F I50-2101F
I50-2100H I50-2101H
I50-2200D I50-2201D
I50-2200F I50-2201F
I50-2200H I50-2201H
I50-2200J
I50-2300D I50-2301D V50-2304D
I50-2300F I50-2301F
I50-2300H I50-2301H
I50-2300J I50-2301J
I50-2500F I50-2501F
V50-2504F
I50-2500H I50-2501H V50-2504H
I50-2500J I50-2501J
I50-2500L
I50-2600F I50-2601F
V50-2604F
I50-2600H I50-2601H V50-2604H
I50-2600J I50-2601J
I50-2600L
I50-2700F I50-2701F
V50-2704F
I50-2700H I50-2701H V50-2704H
I50-2700J I50-2701J
V50-2704J
I50-2700L
I50-2800F I50-2801F
V50-2804F
I50-2800H I50-2801H V50-2804H
I50-2800J I50-2801J
V50-2804J
I50-2800L I50-2801L
I50-2900F I50-2901F
V50-2904F
I50-2900H I50-2901H V50-2904H
I50-2900J I50-2901J
V50-2904J
I50-2900L I50-2901L

Accuracy class
1
0.5
Art.-no. Art.-no.
I50-1910D I50-1911D
I50-1910F I50-1911F
I50-2010D I50-2011D
I50-2010F I50-2011F
I50-2010H I50-2011H
I50-2110D I50-2111D
I50-2110F I50-2111F
I50-2110H I50-2111H
I50-2210D I50-2211D
I50-2210F I50-2211F
I50-2210H I50-2211H
I50-2210J
I50-2310D I50-2311D
I50-2310F I50-2311F
I50-2310H I50-2311H
I50-2310J I50-2311J
I50-2510F I50-2511F
I50-2510H I50-2511H
I50-2510J I50-2511J
I50-2510L
I50-2610F I50-2611F
I50-2610H I50-2611H
I50-2610J I50-2611J
I50-2610L
I50-2710F I50-2711F
I50-2710H I50-2711H
I50-2710J I50-2711J
I50-2710L
I50-2810F I50-2811F
I50-2810H I50-2811H
I50-2810J I50-2811J
I50-2810L I50-2811L
I50-2910F I50-2911F
I50-2910H I50-2911H
I50-2910J I50-2911J
I50-2910L I50-2911L

MBS AG

ASK 130.5
Plug-in current transformer
Secondary current
Primary
current
A
300
400
500

600

750

1000

1200

1250

1500

1600

2000

2400

2500

3000
Primary conductor
Round conductor
Transformer width
Snap-on mounting
Sealed shutter
Current transformer for
tariff applications

130 x 30 mm
30 mm
180 mm

3200

Burden
VA
2.5
5
10
2.5
5
10
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
5
10
15
30
5
10
15
30
5
10
15
30
45
5
10
15
30
45
5
10
15
30
45
10
15
30
45
10
15
30
45
10
15
30
45
10
15
30
45
10
15
30
45

5A

1A

Accuracy class
1
0.5
0.2s
Art.-no. Art.-no.
Art.-no.
I51-1900D I51-1901D
I51-1900F I51-1901F
I51-1900H I51-1901H
I51-2000D I51-2001D
I51-2000F I51-2001F
I51-2000H I51-2001H
I51-2100D I51-2101D
I51-2100F I51-2101F
I51-2100H I51-2101H
I51-2100J I51-2101J
I51-2200D I51-2201D
I51-2200F I51-2201F
I51-2200H I51-2201H
I51-2200J I51-2201J
I51-2300D I51-2301D V51-2304D
I51-2300F I51-2301F
V51-2304F
I51-2300H I51-2301H
I51-2300J I51-2301J
I51-2500F I51-2501F
V51-2504F
I51-2500H I51-2501H V51-2504H
I51-2500J I51-2501J
I51-2500L I51-2501L
I51-2600F I51-2601F
V51-2604F
I51-2600H I51-2601H V51-2604H
I51-2600J I51-2601J
V51-2604J
I51-2600L I51-2601L
I51-2700F I51-2701F
V51-2704F
I51-2700H I51-2701H V51-2704H
I51-2700J I51-2701J
V51-2704J
I51-2700L I51-2701L
I51-2700M
I51-2800F I51-2801F
V51-2804F
I51-2800H I51-2801H V51-2804H
I51-2800J I51-2801J
V51-2804J
I51-2800L I51-2801L
I51-2800M
I51-2900F I51-2901F
V51-2904F
I51-2900H I51-2901H V51-2904H
I51-2900J I51-2901J
V51-2904J
I51-2900L I51-2901L
I51-2900M
I51-3000H I51-3001H V51-3004H
I51-3000J I51-3001J
V51-3004J
I51-3000L I51-3001L
I51-3000M I51-3001M
I51-3100H I51-3101H V51-3104H
I51-3100J I51-3101J
V51-3104J
I51-3100L I51-3101L
I51-3100M I51-3101M
I51-3200H I51-3201H V51-3204H
I51-3200J I51-3201J
V51-3204J
I51-3200L I51-3201L
V51-3204L
I51-3200M I51-3201M
I51-3300H I51-3301H V51-3304H
I51-3300J I51-3301J
V51-3304J
I51-3300L I51-3301L
V51-3304L
I51-3300M
I51-3400H I51-3401H V51-3404H
I51-3400J I51-3401J
V51-3404J
I51-3400L I51-3401L
V51-3404L
I51-3400M

Accuracy class
1
0.5
Art.-no. Art.-no.
I51-1910D I51-1911D
I51-1910F I51-1911F
I51-1910H I51-1911H
I51-2010D I51-2011D
I51-2010F I51-2011F
I51-2010H I51-2011H
I51-2110D I51-2111D
I51-2110F I51-2111F
I51-2110H I51-2111H
I51-2110J I51-2111J
I51-2211D
I51-2210F I51-2211F
I51-2210H I51-2211H
I51-2210J I51-2211J
I51-2310D
I51-2310F I51-2311F
I51-2310H I51-2311H
I51-2310J I51-2311J
I51-2510F I51-2511F
I51-2510H I51-2511H
I51-2510J I51-2511J
I51-2510L I51-2511L
I51-2610F I51-2611F
I51-2610H I51-2611H
I51-2610J I51-2611J
I51-2610L I51-2611L
I51-2710F I51-2711F
I51-2710H I51-2711H
I51-2710J I51-2711J
I51-2710L I51-2711L
I51-2810F
I51-2810H
I51-2810J
I51-2810L

I51-2811F
I51-2811H
I51-2811J
I51-2811L

I51-2910F
I51-2910H
I51-2910J
I51-2910L

I51-2911F
I51-2911H
I51-2911J
I51-2911L

I51-3010H I51-3011H
I51-3010J I51-3011J
I51-3010L I51-3011L
I51-3110H I51-3111H
I51-3110J I51-3111J
I51-3110L I51-3111L
I51-3210H I51-3211H
I51-3210J I51-3211J
I51-3210L I51-3211L
I51-3310H I51-3311H
I51-3310J I51-3311J
I51-3310L I51-3311L
I51-3410H I51-3411H
I51-3410J I51-3411J
I51-3410L I51-3411L
I51-3410M

see page 191


www.mbs-stromwandler.de

95

MBS AG

MBS AG

Low voltage current transformers


for industrial applications
Wound current transformers
WSK 30

Transformer width

61 mm

WSK 40

Transformer width

71 mm

WSK 40 N

Transformer width

71 mm

WSK 60

Transformer width

71 mm

WSK 70.6

Transformer width

60 mm

WSK 70.6 N

Transformer width

60 mm

WSK 31.5

Transformer width

70 mm

NEW

www.mbs-stromwandler.de

97

MBS AG

Wound current transformers


Based on the physical operating principle of current transformers, the required core volume transferring
an amount of power, increases rapidly with a decreasing nominal current. As there are limits on increasing
the transformer size, wound current transformers are being used.
Interim current transformers also belong to the group of wound current transformers. This construction is
mainly used for primary currents of up to 10 A, and achieves a transformation at a higher or lower secondary current values. In addition to their application in adapting a measuring circuit on existing measuring
units, interim current transformers are being used also for lowering the power loss by the transmission of
analogically measured values over great distances. This is made possible by means of a squared dependence of the power loss from the flowing current.

PV = I 2 x Z [VA]
apparent power [VA]

This means when the original nominal current is halved, the conductor loss drops down to 25 % of its
original value.
Indication:

The selection of the nominal power of the initially activated main transformer is achieved
through the application of the following measurement comparisions.

PGH = PZ x

PGH
PZ
PE
PHZ
I1
I2

98

( II )
2
1

+ PE + PHZ

apparent power of the main transformer


secondary performance of the interim transformer (nominal performance inclusive of conductor
losses)
consumption of the interim transformer by nominal current
conductor losses between main- and interim transformer by nominal current
primary nominal current of the interim transformer
secondary nominal current of the interim transformer

www.mbs-stromwandler.de

MBS AG

WSK 30
Wound current transformer
5A

1A

Accuracy class
1
0.5
Art.-no. Art.-no.
30017
30011
30018
30019
30012
30020
30021
30013
30022
30023
30014
30024
30025
30015
30026
30027
30016
30028

Accuracy class
1
0.5
Art.-no. Art.-no.
30217
30211
30218
30219
30212
30220
30221
30213
30222
30223
30214
30224
30225
30215
30226
30227
30216
30228

Secondary current
Primary
current
A
1
2.5
5
10
15
20

Burden
VA
2.5
5
2.5
5
2.5
5
2.5
5
2.5
5
2.5
5

Snap-on mounting

Primary conductor
Round conductor
Transformer width
Snap-on mounting
Sealed shutter

61 mm
Art.-no. 53011
see page 204
Art.-no. 59040
see page 205
www.mbs-stromwandler.de

99

MBS AG

WSK 40
Wound current transformer
5A

1A

Accuracy class
1
0.5
Art.-no. Art.-no.
31044
31011
31045
31012
31046
31013
31047
31014
31048
31015
31049
31016
31050
31017
31051
31018
31052
31019
31053
31020
31054
31021
31055
31022
31056
31023
31057
31024
31058
31025
31059
31026
31060
31027
31061
31028
31062
31029
31063
31030
31064
31031
31065
31032
31066
31033
31067
31034
31068
31035
31069
31036
31070
31037
31071
31038
31072
31039
31073
31040
31074
31041

Accuracy class
1
0.5
Art.-no. Art.-no.
31244
31211
31245
31212
31246
31213
31247
31214
31248
31215
31249
31216
31250
31217
31251
31218
31252
31219
31253
31220
31254
31221
31255
31222
31256
31223
31257
31224
31258
31225
31259
31226
31260
31227
31261
31228
31262
31229
31263
31230
31264
31231
31265
31232
31266
31233
31267
31234
31268
31235
31269
31236
31270
31237
31271
31238
31272
31239
31273
31240
31274
31241

Secondary current
Primary
current
A
1

2.5

10

15

20

25

30

Burden
VA
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
2.5
5
10

Snap-on mounting

Primary conductor
Round conductor
Transformer width
Snap-on mounting
Sealed shutter

100

71 mm
Art.-no. 55012
see page 204
Art.-no. 59041
see page 205
www.mbs-stromwandler.de

MBS AG

WSK 40 N
Wound current transformer
5A

1A

Accuracy class
1
0.5
Art.-no. Art.-no.
31161
31151
31162
31152
31163
31153
31164
31154
31165
31155
31166
31156
31167
31157
31168
31158
31169
31159

Accuracy class
1
0.5
Art.-no. Art.-no.
31361
31351
31362
31352
31363
31353
31364
31354
31365
31355
31366
31356
31367
31357
31368
31358
31369
31359

Secondary current
Primary
current
A
30

40

50

Burden
VA
2.5
5
10
2.5
5
10
2.5
5
10

Snap-on mounting

Primary conductor
Round conductor
Transformer width
Snap-on mounting
Sealed shutter

71 mm
Art.-no. 55011
see page 204
Art.-no. 59041
see page 205

www.mbs-stromwandler.de

101

MBS AG

WSK 60
Wound current transformer
Secondary current
Primary
current
A
5

10

15

20

25

30

PRIMARY

Primary conductor
Round conductor
Transformer width
Snap-on mounting
Sealed shutter

102

71 mm

Art.-no. 59041
see page 205
www.mbs-stromwandler.de

Burden
VA
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15

5A

1A

Accuracy class
1
0.5
Art.-no. Art.-no.
35041
35011
35042
35012
35043
35013
35044
35045
35014
35046
35015
35047
35016
35048
35049
35017
35050
35018
35051
35019
35052
35053
35020
35054
35021
35055
35022
35056
35057
35023
35058
35024
35059
35025
35060
35061
35026
35062
35027
35063
35028
35064

Accuracy class
1
0.5
Art.-no. Art.-no.
35241
35211
35242
35212
35243
35213
35244
35245
35214
35246
35215
35247
35216
35248
35249
35217
35250
35218
35251
35219
35252
35253
35220
35254
35221
35255
35222
35256
35257
35223
35258
35224
35259
35225
35260
35261
35226
35262
35227
35263
35228
35264

MBS AG

WSK 70.6
Wound current transformer
Secondary current
Primary
current
A
25

30

40

50

60

75

80

100

Primary conductor
Round conductor
Transformer width
Snap-on mounting
Sealed shutter

Burden
VA
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15

5A

1A

Accuracy class
1
0.5
Art.-no. Art.-no.
32038
32011
32039
32012
32040
32013
32041
32042
32014
32043
32015
32044
32016
32045
32046
32017
32047
32018
32048
32019
32049
32050
32020
32051
32021
32052
32022
32053
32054
32023
32055
32024
32056
32025
32057
32058
32026
32059
32027
32060
32028
32061
32062
32029
32063
32030
32064
32031
32065
32066
32032
32067
32033
32068
32034
32069

Accuracy class
1
0.5
Art.-no. Art.-no.
32238
32211
32239
32212
32240
32213
32241
32242
32214
32243
32215
32244
32216
32245
32246
32217
32247
32218
32248
32219
32249
32250
32220
32251
32221
32252
32222
32253
32254
32223
32255
32224
32256
32225
32257
32258
32226
32259
32227
32260
32228
32261
32262
32229
32263
32230
32264
32231
32265
32266
32232
32267
32233
32268
32234
32269

60 mm

Art.-no. 59043
see page 205
www.mbs-stromwandler.de

103

MBS AG

WSK 70.6 N
Wound current transformer
Secondary current
Primary
current
A
25

30

40

50

60

75

80

100

Primary conductor
Round conductor
Transformer width
Snap-on mounting
Sealed shutter

104

60 mm

Art.-no. 59041
see page 205

www.mbs-stromwandler.de

Burden
VA
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15

5A

1A

Accuracy class
1
0.5
Art.-no. Art.-no.
89047
89011
89048
89012
89049
89013
89050
89051
89015
89052
89016
89053
89017
89054
89055
89019
89056
89020
89057
89021
89058
89059
89023
89060
89024
89061
89025
89062
89063
89027
89064
89028
89065
89029
89066
89067
89031
89068
89032
89069
89033
89070
89071
89035
89072
89036
89073
89037
89074
89075
89039
89076
89040
89077
89041
89078

Accuracy class
1
0.5
Art.-no. Art.-no.
89247
89211
89248
89212
89249
89213
89250
89251
89215
89252
89216
89253
89217
89254
89255
89219
89256
89220
89257
89221
89258
89259
89223
89260
89224
89261
89225
89262
89263
89227
89264
89228
89265
89229
89266
89267
89231
89268
89232
89269
89233
89270
89271
89235
89272
89236
89273
89237
89274
89275
89239
89276
89240
89277
89241
89278

MBS AG

WSK 31.5
Wound current transformer
Secondary current
Primary
current
A
25

30

40

50

60

75

80

100

150

Primary conductor
Round conductor
Transformer width
Snap-on mounting
Sealed shutter
Current transformer for
tariff applications

Burden
VA
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15

5A

1A

Accuracy class
1
0.5
Art.-no. Art.-no.
33047
33011
33048
33012
33049
33013
33050
33014
33051
33015
33052
33016
33053
33017
33054
33018
33055
33019
33056
33020
33057
33021
33058
33022
33059
33023
33060
33024
33061
33025
33062
33026
33063
33027
33064
33028
33065
33029
33066
33030
33067
33031
33068
33032
33069
33033
33070
33034
33071
33035
33072
33036
33073
33037
33074
33038
33075
33039
33076
33040
33077
33041
33078
33042
33079
33043
33080
33044
33081
33045
33082
33046

Accuracy class
1
0.5
Art.-no. Art.-no.
33247
33211
33248
33212
33249
33213
33250
33214
33251
33215
33252
33216
33253
33217
33254
33218
33255
33219
33256
33220
33257
33221
33258
33222
33259
33223
33260
33224
33261
33225
33262
33226
33263
33227
33264
33228
33265
33229
33266
33230
33267
33231
33268
33232
33269
33233
33270
33234
33271
33235
33272
33236
33273
33237
33274
33238
33275
33239
33276
33240
33277
33241
33278
33242
33279
33243
33280
33244
33281
33245
33282
33246

70 mm

Art.-no. 59045
see page 205
see page 194
www.mbs-stromwandler.de

105

MBS AG

Split core current transformers, series KBU

www.mbs-stromwandler.de

MBS AG

Split core current transformers


KBU 23

Primary conductor
Transformer width

20 x 30 mm
93 mm

KBU 58

Primary conductor
Transformer width

50 x 80 mm
125 mm

KBU 812

Primary conductor
Transformer width

80 x 120 mm
155 mm

KBU 816

Primary conductor
Transformer width

80 x 160 mm
195 mm

www.mbs-stromwandler.de

107

MBS AG

KBU 23
Split core current transformer
Secondary current
Primary
current
A
100
150
200
250
300

C1

400

Burden
VA
1.25
1.5
1.5
1.5
1.5
3.75
2.5
5

5A

1A

Accuracy class
1
0.5
Art.-no. Art.-no.
80041
80042
80043
80044
80035
80045
80036
80046

Accuracy class
1
0.5
Art.-no. Art.-no.
80241
80242
80243
80244
80235
80245
80236
80246

KBU 58
C

Secondary current
Primary
current
A
250

D
300
400
500
B

600
750
800
1000

Type
A
B
C/C1
D
E

108

KBU 23
93
106
34/58
20
30

KBU 58
125
158
34/58
50
80
www.mbs-stromwandler.de

Burden
VA
1
1.5
1.5
2.5
1.5
2.5
2.5
5
2.5
5
2.5
5
2.5
7.5
5
10

5A

1A

Accuracy class
1
0.5
Art.-no. Art.-no.
80051
80061
80052
80062
80053
80063
80054
80064
80055
80065
80056
80066
80057
80067
80058
80068

Accuracy class
1
0.5
Art.-no. Art.-no.
80251
80261
80252
80262
80253
80263
80254
80264
80255
80265
80256
80266
80257
80267
80258
80268

MBS AG

KBU 812
Split core current transformer
Secondary current
Primary
current
A
250
300
400
500
600
750
800
1000
1200
1250
1500

Burden
VA
1
1.5
1.5
2.5
1.5
2.5
2.5
5
2.5
5
2.5
5
2.5
7.5
5
10
5
10
7.5
15
7.5
15

5A

1A

Accuracy class
1
0.5
Art.-no. Art.-no.
80071
80091
80072
80092
80073
80093
80074
80094
80075
80095
80076
80096
80077
80097
80078
80098
80079
80099
80080
80100
80081
80101

Accuracy class
1
0.5
Art.-no. Art.-no.
80271
80291
80272
80292
80273
80293
80274
80294
80275
80295
80276
80296
80277
80297
80278
80298
80279
80299
80280
80300
80281
80301

KBU 816
Secondary current
Primary
current
A
1000
1200
1500
1600
2000
2500
Type
A
B
C/C1
D
E

KBU 812
155
198
34/58
80
120

KBU 816
195
243
64/79
80
160

3000
4000
5000

Burden
VA
10
15
10
15
10
15
10
15
10
15
10
15
15
30
15
30
15
30

5A

1A

Accuracy class
1
0.5
Art.-no. Art.-no.
80140
80110
80141
80142
80111
80143
80144
80112
80145
80113
80146
80114
80147
80115
80148
80116
80149
80117
80150
80119
80151
80120
80152
80122
80153
80154
80123
80155
80124
80156
80125
80157
80126

Accuracy class
1
0.5
Art.-no. Art.-no.
80340
80310
80341
80342
80311
80343
80344
80312
80345
80313
80346
80314
80347
80315
80348
80316
80349
80317
80350
80319
80351
80320
80352
80322
80353
80354
80323
80355
80324
80356
80325
80357
80326

www.mbs-stromwandler.de

109

MBS AG

Summation current transformers,


series KSU / SUSK

www.mbs-stromwandler.de

MBS AG

Low voltage current transformers


for industrial applications
Summation current transformers
KSU

Summation current transformer


Transformer width
Transformer depth

SUSK

127 mm
57 mm

Summation current transformer


Transformer width
Transformer depth

156 mm
65 mm

www.mbs-stromwandler.de

111

MBS AG

Guidance when ordering summation current transformers

Summation current transformers are suitable for the summation of several synchronized alternating currents with
similar phases but with differing load phase shifts. It is also possible to have the summation of currents with varied
nominal voltages of similar phase positions. These measurements cannot be used for tariff applications, as the
existing voltage differences are recorded as errors.
With the counter connection of the main transformer to the summation current transformer, it is possible to receive
secondary currents which are proportional to the differences of the primary input currents.
The built-in technical know-how enables the summation current transformers to add secondary currents of varying
nominal transmissions from the main transformer.
The secondary connections of each main transformer are connected to the allocated primary inputs of the summation
current transformers.
The number of windings of individual partially wound primary circuits of the summation current transformer is proportionally aligned to the ratio of the primary nominal current of the corresponding main transformer, and to the sum
of the nominal currents of all the summation current transformers being connected to the main transformer.
For the visual display of the current, a measuring unit can be used with a measuring range similar to the secondary
nominal current of the summation current transformers.
It is irrelevant for the main transformers with similar nominal transmission ratios, to which primary circuit of the
summation current transformer the connection is made.
With main transformers of different nominal transmission ratios, care must be taken to adhere to the assigned
connection to the terminals of the summation current transformers.
Is the current flow in the main transformer interrupted, the secondary circuit of the main transformer must neither be
short-circuited nor be connected to the summation current transformer, or to the main transformer.
Summation current transformers with unallocated primary circuits must remain open for a later connection to an
additional main transformer. The secondary output current of the summation current transformer is in this instance
lower than the secondary nominal current of the summation current transformer by a quantity equal to the ratio of
the primary nominal current of this missing main transformer and the sum of all the primary nominal currents of the
main transformer.
The nominal secondary current of a main transformer must be equal to the nominal primary current of the input
allocation of the summation current transformer.

112

www.mbs-stromwandler.de

MBS AG

Guidance when ordering summation current transformers


Please find below an example for the correct selection of measuring components
for summation current transformers.
Example:
Actual situation:

3 transmission ratios

1000
800
600
2400

Overall current

/
/
/
/

5
5
5
5

VA
VA
VA
VA

Burden:

1 current meter
1 power recorder

Looking for:

1 summation current transformer and the VA power of an individual main


transformer

Required active performance of the summation current transformer:


Current meter
Performance recorder
Measurement conductor loss
consumption Po summation ct
Interim result

1.5
7.0
1.5
4.0
14.0

VA
VA
VA
VA
VA

The individual transformer must provide its VA share from this 14.0 VA corresponding to its ratio to the total transmission.
Consideration must also be given to the respective power loss between the main transformer and the summation
transformer plus other possible losses.

1. Main transformer 1000 / 5A

1000
x 14.0 = 5.83 VA + additional possible losses
2400

2. Main transformer 800 / 5A

800
x 14.0 = 4.67 VA + additional possible losses
2400

3. Main transformer 600 / 5A

600
x 14.0 = 3.50 VA + additional possible losses
2400

The VA values of the main transformers are to be rounded up to the corresponding VA values in our charts.
The ratio of the primary current of a main transformer to the sum of the primary currents of all main current
transformers the ratio must not exceed 1:8.

Important indication to the power measuring


Too many rising deviation can prevent the measuring transformer acting as a current transformer from
fulfilling its protective function with regard to the connected measuring units, as in normal operation its
functions is well below its saturation limit, and in the event of over currents, the saturation limit is reached
considerably later and takes the function almost as a protection current transformer.
If there is too much of a decrease, the measuring transformer, as a result of the continuous excess
demands will reach the saturation limit too soon and indirectly function as a switch, rendering a
measuring impossible.

www.mbs-stromwandler.de

113

MBS AG

KSU 23
Summation current transformer
Secondary current

5A

1A

Primary
current
A
1+1

1+1+1

5+5

5+5+5

Accuracy class
1
0.5
Art.-no. Art.-no.
41114
41111
41115
41112
41116
41113
41117
41118
41119
41130
41127
41131
41128
41132
41129
41133
41014
41011
41015
41012
41016
41013
41017
41018
41019
41030
41027
41031
41028
41032
41029
41033

Accuracy class
1
0.5
Art.-no. Art.-no.
41314
41311
41315
41312
41316
41313
41317
41318
41319
41330
41327
41331
41328
41332
41329
41333
41214
41211
41215
41212
41216
41213
41217
41218
41219
41230
41227
41231
41228
41232
41229
41233

Type

Burden
VA
5
10
15
20
25
30
5
10
15
30
5
10
15
20
25
30
5
10
15
30

Connection example for different ratios:


AK-AL = 1000/5
BK-BL = 800/5
CK-CL = 600/5

Connection diagram

Primary conductor
Round conductor
Transformer width
Transformer depth
Snap-on mounting
Sealed shutter
2 pieces primary

114

127 mm
57 mm

Art.-no. 59041
see page 205

www.mbs-stromwandler.de

MBS AG

SUSK 38
Summation current transformer
Secondary current

5A

1A

Primary
current
A
5+5+5

5+5+5+5

5+5+5+5+5

5+5+5+5+5+5

5+5+5+5+5+5+5

5+5+5+5+5+5+5+5

Accuracy class
1
0.5
Art.-no. Art.-no.
40015
40011
40016
40012
40017
40014
40018
40026
40023
40027
40024
40028
40025
40029
40030
40037
40034
40038
40035
40039
40036
40040
40048
40045
40049
40046
40050
40047
40051
40060
40057
40061
40058
40062
40059
40063
40071
40068
40072
40069
40073
40070
40074

Accuracy class
1
0.5
Art.-no. Art.-no.
40215
40211
40216
40212
40217
40214
40218
40226
40223
40227
40224
40228
40225
40229
40230
40237
40234
40238
40235
40239
40236
40240
40248
40245
40249
40246
40250
40247
40251
40260
40257
40261
40258
40262
40259
40263
40271
40268
40272
40269
40273
40270
40274

Type

Burden
VA
5
10
15
30
5
10
15
25
30
5
10
15
30
5
10
15
30
5
10
15
30
5
10
15
30

Primary current 1 A, see page 116

Connection diagram

Primary conductor
Round conductor
Transformer width
Transformer depth
Snap-on mounting
Sealed shutter
secondary no.
Current transformer for
tariff applications

156 mm
65 mm

Art.-no. 59041 (primary)


Art.-no. 59042 (secondary)
see page 205
see page 195

www.mbs-stromwandler.de

115

MBS AG

SUSK 38
Summation current transformer
Secondary current

5A

1A

Primary
current
A
1+1+1

Accuracy class
1
0.5
Art.-no. Art.-no.
40315
40311
40316
40312
40317
40314

1+1+1+1

1+1+1+1+1

1+1+1+1+1+1

1+1+1+1+1+1+1

1+1+1+1+1+1+1+1

Accuracy class
1
0.5
Art.-no. Art.-no.
40115
40111
40116
40112
40117
40114
40118
40318
40126
40123
40127
40124
40128
40125
40129
40329
40130
40330
40137
40134
40138
40135
40139
40136
40140
40340
40148
40145
40149
40146
40150
40147
40151
40351
40160
40157
40161
40158
40162
40159
40163
40363
40171
40168
40172
40169
40173
40170
40174
40374

Typ

Burden
VA
5
10
15
30
5
10
15
25
30
5
10
15
30
5
10
15
30
5
10
15
30
5
10
15
30

40326
40327
40328

40323
40324
40325

40337
40338
40339

40334
40335
40336

40348
40349
40350

40345
40346
40347

40360
40361
40362

40357
40358
40359

40371
40372
40373

40368
40369
40370

Primary current 5 A, see page 115

Connection example for different ratios :


AK-AL
BK-BL
CK-CL
DK-DL
EK-EL
FK-FL
GK-GL
HK-HL

Primary conductor
Round conductor
Transformer width
Transformer depth
Snap-on mounting
Sealed shutter
secondary no.

156 mm
65 mm

Art.-no. 59041 (primary)


Art.-no. 59042 (secondary)
see page 205

Current transformer for


tariff applications

116

see page 195

www.mbs-stromwandler.de

= 1000/5
= 800/5
= 600/5
= 400/5
= 400/5
= 300/5
= 300/5
= 300/5

MBS AG

Low voltage current transformers


for industrial applications
Special current transformers
NH

Current transformers for fuse rails

www.mbs-stromwandler.de

117

MBS AG

NH-Current transformers for fuse rails


Size 1, 2 and 3
Housing material:

Technyl A20 V25 N025. 200 C

Configuration:

Current transformers for direct fitment in connection with low voltage high performance fuses
with contact-knives and NH-fuse sets according to DIN 43620/1.
NH current transformers are arranged with 2 or 4 tip jacks respectively and can
be operated continuously in open state.
Loss motion voltage / open circuit voltage with sec. 5 A approx. 3 6 V and with sec. 1 A
approx. 13 25 V.
The current transformers can also be supplied in dual change-over mode for secondary
application.

118

www.mbs-stromwandler.de

MBS AG

NH 6.1
Current transformer for fuse rails
Secondary current
Primary
current
A
100
150
200
250
300

Burden
VA
1.25
2.5
3.5
4
5

5A

1A

Accuracy class
3
Art.-no.
50011
50012
50013
50014
50015

Accuracy class
3
Art.-no.
50211
50212
50213
50214
50215

NH 6.1 2U
Secondary current
Primary
current
A
200-100
300-150

Primary conductor
Round conductor
Transformer width
Snap-on mounting
Sealed shutter

Burden
VA
2.5-1.25
5-2.5

5A

1A

Accuracy class
3
Art.-no.
50111
50112

Accuracy class
3
Art.-no.
50311
50312

24 x 6 mm

52 mm

www.mbs-stromwandler.de

119

MBS AG

NH 6.2
Current transformer for fuse rails
Secondary current
Primary
current
A
100
150
200
250
300
400

Burden
VA
1.25
2.5
3.5
4
5
5

5A

1A

Accuracy class
3
Art.-no.
50021
50022
50023
50024
50025
50026

Accuracy class
3
Art.-no.
50221
50222
50223
50224
50225
50226

NH 6.2 2U
Secondary current
Primary
current
A
200-100
300-150
400-200

Primary conductor
Round conductor
Transformer width
Snap-on mounting
Sealed shutter

120

30 x 6 mm

60 mm

www.mbs-stromwandler.de

Burden
VA
2.5-1.25
5-2.5
5-2.5

5A

1A

Accuracy class
3
Art.-no.
50121
50122
50123

Accuracy class
3
Art.-no.
50321
50322
50323

MBS AG

NH 6.3
Current transformer for fuse rails
Secondary current
Primary
current
A
150
200
250
300
400
500
600

Burden
VA
2.5
3.5
4
5
5
5
10

5A

1A

Accuracy class
3
Art.-no.
50031
50032
50033
50034
50035
50036
50037

Accuracy class
3
Art.-no.
50231
50232
50233
50234
50235
50236
50237

NH 6.3 2U
Secondary current
Primary
current
A
300-150
400-200
600-300

Primary conductor
Round conductor
Transformer width
Snap-on mounting
Sealed shutter

Burden
VA
5-2.5
5-2.5
10-5

5A

1A

Accuracy class
3
Art.-no.
50131
50132
50133

Accuracy class
3
Art.-no.
50331
50332
50333

32 x 6 mm

74 mm

www.mbs-stromwandler.de

121

MBS AG

MBS AG

Low voltage current transformers


for industrial applications
Protection current transformers
Protection tube current transformers
SASR 22.3

Round conductor
Transformer width

22.5 mm
61 mm

Protection plug-in current transformers


SASK 21.3

Primary conductor
Round conductor
Transformer width

SASK 31.5

Primary conductor
Round conductor
Transformer width

SASK 31.6

20 x 10 mm
19.2 mm
61 mm

30 x 10
2 x 20 x 10
28
61

mm
mm
mm
mm

30 x 10
20 x 13
23
95

mm
mm
mm
mm

Primary conductor
Round conductor
Transformer width

www.mbs-stromwandler.de

123

MBS AG

Protection current transformers Technical concepts


Application: Current transformers are for the galvanic separation, proportional transformation of alternating currents of larger
currents into smaller, direct measurable values. There are two categories subject to their application:
measuring transformers
protection transformers.
All current transformers manufactured by MBS are for low voltage applications with a max. phase to phase voltage of 0.72 kV.
Measuring transformer: Measuring transformers are used to measure current, power, power factor and energy consumption combined with an equivalent measurement unit. Using its magnetic circle, current transformers allow a high transmission accuracy in the
nominal current range, whilst simultaniously protecting the connected appliances against over current. The magnetic saturation in
the measuring core ensures protection in the event of an over current.
Protection current transformers: Protection current transformers are for the control of protecting relays which have the task to
separate switched circuits in the event of over current. For a save function of these relays a proportional transfer ratio of the transformer up to a multiple of the nominal current is necessary. The dimensioning of this transformer unit secures a proportional current
transfer, up to a multiple of the nominal currents, determined by the protection class.
Technical standards: All MBS current transformers are produced in accordance with the technical requirements of DIN EN 60044/1
(edition 12/2003)
Technical characteristics: Application use: Indoors, without condensation
Protection current transformers:

Ambient temperature:
Housing material:
Housing form:
Isolation class:
Thermal rated nominal continuous current:
Secondary rated currents:
Thermal rated short time current:
Max. excess temperature of the secondary winding:
Isolating test voltage:

- 5 C ....+ 40 C.
Polycarbonate, self-extinguishing
halve-cup-shaped, ultrasonically welded
E
1.2 x IN
5 A or 1 A
60 x IN (max.100 kA)
75 C
3 kV UEFF; 50 Hz, 1 min

Safety instructions: The protection current transformers physical characteristics has its many advantages and with all these built-in
features it is very easy to attend to this transformer with their secondary circuits open. This can be very harmful to the operator or
transformers as multiple kilovolt surges can occure. In order to prevent any mishaps an operation as described above ist forbidden.
Ordering instructions: For the correct processing of your order, please make available the following specification:
Transformer type
Transmission ratio
Accuracy class
Rated burden

Accuracy classes of current transformers:


Class

current error (+/- %) by % IN


1%

5%

20 %

phase displacement error (+/- minutes) by % IN


50 % 100 % 120 %

total
error by
n x IN

50 % 100 % 120 %

1%

5%

20 %

30

15

10

10

10

> 10

Measuring transformer
0.20
0.35
0.75
0.2s

0.20

0.20

0.2

0.75

0.35

0.20

0.20

30

15

10

10

> 10

0.5s

1.50

0.75

0.50

0.50

0.50

90

45

30

30

30

> 10

0.5

1.50

0.75

0.50

0.50

90

45

30

30

> 10

3.00

1.50

1.00

1.00

180

90

60

60

> 10

3.00

3.00

3.00

3.00

120

120

120

> 10

Protection current transformer


5P(n)

3.00

1.50

1.00

1.00

180

90

60

60

< 5

10P(n)

3.00

3.00

3.00

120

120

120

< 10

n over current rated limiting factor

124

www.mbs-stromwandler.de

MBS AG

SASR 22.3
Protection tube current transformer
Secondary current
Primary
current
A
100
125
150
200
250
300

Burden
VA
1
1
1.5
1
1.5
1
1.5
1
1.5
1
1.5

5A
Protection class
5P5
10P5
Art.-no.
Art.-no.

1A
Protection class
5P5
10P5
Art.-no.
Art.-no.
S04-1317B

S04-1506B S04-1507B
S04-1516C S04-1517C
S04-1606B S04-1607B
S04-1616C S04-1617C
S04-1706B S04-1707B
S04-1716C S04-1717C
S04-1806B S04-1807B
S04-1816C S04-1817C
S04-1906B S04-1907B
S04-1907C

S04-1916C S04-1917C

Snap-on mounting

Primary conductor
Round conductor
Transformer width
Snap-on mounting
Sealed shutter
Current transformer for
industrial application
Current transformer for
tariff applications

22.5 mm
61 mm
Art.-no. 53011
see page 204
Art.-no. 59040
see page 205
see page 35
see page 167

www.mbs-stromwandler.de

125

MBS AG

SASK 21.3
Protection plug-in current transformer
Secondary current
Primary
current
A
125
150
200

5A

Protection class
Burden
5P5
10P5
VA
Art.-no.
Art.-no.
1
S03-1506B S03-1507B
1.5
1
S03-1606B S03-1607B
1.5
1
S03-1706B S03-1707B
1.5

Snap-on mounting

Primary conductor
Round conductor
Transformer width
Snap-on mounting

20 x 10 mm
19.2 mm
61 mm
Art.-no. 55014
see page 204
Art.-no. 59040
see page 205

Sealed shutter
Current transformer
for industrial applications
Current transformer for
tariff applications

126

see page 43
see page 168

www.mbs-stromwandler.de

1A
Protection class
5P5
10P5
Art.-no.
Art.-no.
S03-1516C S03-1517C
S03-1616C S03-1617C
S03-1716C S03-1717C

MBS AG

SASK 31.5
Protection plug-in current transformer
Secondary current
Primary
current
A
75
80
100
125
150
200

250
300
400
500
600
750

Burden
VA
1
1
1
1.5
1
1.5
1
1.5
1
1.5
2.5
1.5
2.5
1.5
2.5
1.5
2.5
1.5
2.5
1.5
2.5
1.5
2.5
5

5A
Protection class
5P5
10P5
Art.-no.
Art.-no.

1A
Protection class
5P5
10P5
Art.-no.
Art.-no.
S17-1116B S17-1117B
S17-1216B S17-1217B

S17-1306B S17-1307B
S17-1316C S17-1317C
S17-1506B S17-1507B
S17-1507C
S17-1606B S17-1607B
S17-1606C S17-1607C
S17-1706B S17-1707B
S17-1706C S17-1707C
S17-1806C
S17-1806D
S17-1906C
S17-1906D
S17-2006C
S17-2006D
S17-2106C
S17-2106D
S17-2206C

S17-1807C
S17-1807D
S17-1907C
S17-1907D
S17-2007C
S17-2007D
S17-2107C
S17-2107D
S17-2207C

S17-2306C S17-2307C

S17-1516C S17-1517C
S17-1616C S17-1617C
S17-1716C
S17-1716D
S17-1816C
S17-1816D
S17-1916C
S17-1916D
S17-2016C
S17-2016D
S17-2116C
S17-2116D
S17-2216C
S17-2216D
S17-2316C
S17-2316D

S17-1717C
S17-1717D
S17-1817C
S17-1817D
S17-1917C
S17-1917D
S17-2017C
S17-2017D
S17-2117C
S17-2117D
S17-2217C
S17-2217C
S17-2317C
S17-2317D
S17-2317F

Snap-on mounting
Primary conductor
Round conductor
Transformer width
Snap-on mounting
Sealed shutter
Current transformer
for industrial applications
Current transformer for
tariff applications

30 x 10 mm
2 x 20 x 10 mm
28 mm
61 mm
Art.-no. 55011
see page 204
Art.-no. 59041
see page 205
see page 49
see page 171

www.mbs-stromwandler.de

127

MBS AG

SASK 31.6
Protection plug-in current transformer
5A

Secondary current
Primary
current
A
50
60
80
100

150

200

250

300

400

500

600

Primary conductor

30 x 10 mm
20 x 13 mm
23 mm
95 mm

Art.-no. 59044
see page 205

Round conductor
Transformer width
Snap-on mounting
Sealed shutter
Current transformer
for industrial applications
Current transformer for
tariff applications

128

see page 51
see page 172

www.mbs-stromwandler.de

Burden
VA
1.5
2.5
1.5
2.5
1.5
2.5
1.5
2.5
5
2.5
5
7.5
2.5
5
7.5
10
2.5
5
7.5
10
2.5
5
10
2.5
5
7.5
10
15
2.5
5
7.5
10
15
2.5
5
7.5
10
15

5P5
Art.-no.
S19-0906C
S19-0906D
S19-1006C
S19-1006D
S19-1206C
S19-1206D
S19-1306C
S19-1306D
S19-1306F
S19-1606D
S19-1606F
S19-1606G
S19-1706D
S19-1706F
S19-1706G
S19-1706H
S19-1806D
S19-1806F
S19-1806G
S19-1806H
S19-1906D
S19-1906F
S19-1906H
S19-2006D
S19-2006F
S19-2006G
S19-2006H
S19-2006J
S19-2106D
S19-2106F
S19-2106G
S19-2106H
S19-2106J
S19-2206D
S19-2206F
S19-2206G
S19-2206H
S19-2206J

Protection class
10P5
5P10
Art.-no.
Art.-no.
S19-0907C
S19-0907D
S19-1007C
S19-1007D
S19-1207C S19-1208C
S19-1207D
S19-1307C S19-1308C
S19-1307D
S19-1307F
S19-1607D S19-1608D
S19-1607F
S19-1607G
S19-1707D S19-1708D
S19-1707F
S19-1707G
S19-1707H
S19-1807D S19-1808D
S19-1807F S19-1808F
S19-1807G
S19-1807H
S19-1907D S19-1908D
S19-1907F S19-1908F
S19-1907H
S19-2007D S19-2008D
S19-2007F S19-2008F
S19-2007G
S19-2007H
S19-2007J
S19-2107D S19-2108D
S19-2107F S19-2108F
S19-2107G S19-2108G
S19-2107H
S19-2107J
S19-2207D S19-2208D
S19-2207F S19-2208F
S19-2207G S19-2208G
S19-2207H
S19-2207J

10P10
Art.-no.

S19-1009C
S19-1209C
S19-1309C
S19-1309D
S19-1609D

S19-1709D
S19-1709F

S19-1809D
S19-1809F

S19-1909D
S19-1909F
S19-2009D
S19-2009F

S19-2109D
S19-2109F
S19-2109G

S19-2209D
S19-2209F
S19-2209G
S19-2209H

MBS AG

SASK 31.6
Protection plug-in current transformer
1A

Secondary current
Primary
current
A
50
60
80

100
150

200

250

300

400

500

600

Primary conductor
Round conductor
Transformer width
Snap-on mounting
Sealed shutter
Current transformer
for industrial applications
Current transformer for
tariff applications

Burden
VA
1.5
2.5
1.5
2.5
1.5
2.5
5
2.5
5
2.5
5
7.5
2.5
5
7.5
10
2.5
5
7.5
10
2.5
5
10
2.5
5
7.5
10
15
2.5
5
7.5
10
15
2.5
5
7.5
10
15

5P5
Art.-no.
S19-0916C
S19-0916D
S19-1016C
S19-1016D
S19-1216C
S19-1216D
S19-1316D
S19-1316F
S19-1616D
S19-1616F
S19-1616G
S19-1716D
S19-1716F
S19-1716G
S19-1716H
S19-1816D
S19-1816F
S19-1816G
S19-1816H
S19-1916D
S19-1916F
S19-1916H
S19-2016D
S19-2016F
S19-2016G
S19-2016H
S19-2016J
S19-2116D
S19-2116F
S19-2116G
S19-2116H
S19-2116J
S19-2216D
S19-2216F
S19-2216G
S19-2216H
S19-2216J

Protection class
10P5
5P10
Art.-no.
Art.-no.
S19-0917C
S19-0917D
S19-1017C S19-1018C
S19-1017D
S19-1217C S19-1218C
S19-1217D
S19-1217F
S19-1317D S19-1318D
S19-1317F
S19-1617D S19-1618D
S19-1617F
S19-1617G
S19-1717D S19-1718D
S19-1717F S19-1718F
S19-1717G
S19-1717H
S19-1817D S19-1818D
S19-1817F S19-1818F
S19-1817G
S19-1817H
S19-1917D S19-1918D
S19-1917F S19-1918F
S19-1917H
S19-2017D S19-2018D
S19-2017F S19-2018F
S19-2017G S19-2018G
S19-2017H
S19-2017J
S19-2117D S19-2118D
S19-2117F S19-2118F
S19-2117G S19-2118G
S19-2117H
S19-2117J
S19-2217D S19-2218D
S19-2217F S19-2218F
S19-2217G S19-2218G
S19-2217H
S19-2217J

10P10
Art.-no.

S19-1019C
S19-1219C

S19-1319D
S19-1619D

S19-1719D
S19-1719F

S19-1819D
S19-1819F

S19-1919D
S19-1919F
S19-2019D
S19-2019F
S19-2019G

S19-2119D
S19-2119F
S19-2119G
S19-2119H
S19-2219D
S19-2219F
S19-2219G
S19-2219H

30 x 10 mm
20 x 13 mm
23 mm
95 mm

Art.-no. 59044
see page 205
see page 51
see page 172

www.mbs-stromwandler.de

129

MBS AG

MBS AG

Protection plug-in current transformers


SASK 421.4

Primary conductor
Round conductor
Transformer width

SASK 41.4

Primary conductor

40 x 10
2 x 30 x 5
32
71

mm
mm
mm
mm

Round conductor
Transformer width

40 x 12
30 x 15
32
95

mm
mm
mm
mm

Primary conductor
Round conductor
Transformer width

40 x 10 mm
32 mm
150 mm

Round conductor
Transformer width

SASK 41.6

SASK 41.10

20 x 10 mm
20 mm
71 mm

Primary conductor

www.mbs-stromwandler.de

131

MBS AG

SASK 421.4
Protection plug-in current transformer
Secondary current
Primary
current
A
200
250
300
400

Primary conductor
Round conductor
Transformer width
Snap-on mounting
Sealed shutter

20 x 10 mm
20 mm
71 mm

Art.-no. 59041
see page 205

Current transformer
for industrial applications

132

see page 55

www.mbs-stromwandler.de

5A

Protection class
Burden
5P5
10P5
VA
Art.-no.
Art.-no.
1.5
S23-1706C S23-1707C
2.5
S23-1706D S23-1707D
1.5
S23-1806C S23-1807D
2.5
S23-1806D S23-1807C
1.5
S23-1906C S23-1907C
2.5
S23-1906D S23-1907D
1.5
S23-2006C S23-2007C
2.5
S23-2006D S23-2007D

1A
Protection class
5P5
10P5
Art.-no.
Art.-no.
S23-1716C S23-1717C
S23-1716D S23-1717D
S23-1816C S23-1817D
S23-1816D S23-1817C
S23-1916C S23-1917C
S23-1916D S23-1917D
S23-2016C S23-2017C
S23-2016D S23-2017D

MBS AG

SASK 41.4
Protection plug-in current transformer
Secondary current
Primary
current
A
120
125
150
200
250
300
400
500
600
750

Primary conductor
Round conductor
Round conductor
Transformer width
Snap-on mounting
Sealed shutter
Current transformer
for industrial applications
Current transformer for
tariff applications

40 x 10 mm
2 x 30 x 5 mm
32 mm
71 mm
Art.-no. 55012
see page 204
Art.-no. 59041
see page 205

5A

Protection class
Burden
5P5
10P5
VA
Art.-no.
Art.-no.
1
S24-1406B S24-1407B
1
S24-1506B S24-1507B
1
S24-1606B S24-1607B
1.5
S24-1607C
1.5
S24-1706C S24-1707C
1.5
S24-1806C S24-1807C
2.5
S24-1807D
1.5
S24-1906C S24-1907C
2.5
S24-1906D S24-1907D
1.5
S24-2006C S24-2007C
2.5
S24-2006D S24-2007D
1.5
S24-2106C S24-2107C
2.5
1.5
S24-2206C S24-2207C
2.5
1.5
S24-2306C S24-2307C
2.5
S24-2307D

1A
Protection class
5P5
10P5
Art.-no.
Art.-no.
S24-1416B S24-1417B
S24-1516B S24-1517B
S24-1616C
S24-1716C
S24-1816C
S24-1816D
S24-1916C
S24-1916D
S24-2016C
S24-2016D
S24-2116C
S24-2116D
S24-2216C
S24-2216D
S24-2316C
S24-2316D

S24-1617C
S24-1717C
S24-1817C
S24-1817D
S24-1917C
S24-1917D
S24-2017C
S24-2017D
S24-2117C
S24-2117D
S24-2217C
S24-2217D
S24-2317C
S24-2317D

Snap-on mounting

see page 56
see page 174

www.mbs-stromwandler.de

133

MBS AG

SASK 41.6
Protection plug-in current transformer
5A

Secondary current
Primary
current
A
100
150
200

250

300

400

500

600

Primary conductor

40 x 12 mm
30 x 15 mm
32 mm
95 mm

Art.-no. 59044
see page 205

Round conductor
Transformer width
Snap-on mounting
Sealed shutter
Current transformer
for industrial applications
Current transformer for
tariff applications

134

see page 61
see page 176

www.mbs-stromwandler.de

Burden
VA
1.5
2.5
2.5
5
2.5
5
7.5
10
2.5
5
7.5
10
2.5
5
7.5
10
2.5
5
7.5
10
2.5
5
7.5
10
2.5
5
7.5
10

5P5
Art.-no.
S30-1306C
S30-1306D
S30-1606D
S30-1606F
S30-1706D
S30-1706F
S30-1706G
S30-1806D
S30-1806F
S30-1806G
S30-1806H
S30-1906D
S30-1906F
S30-1906G
S30-1906H
S30-2006D
S30-2006F
S30-2006G
S30-2006H
S30-2106D
S30-2106F
S30-2106G
S30-2106H
S30-2206D
S30-2206F
S30-2206G
S30-2206H

Protection class
10P5
5P10
Art.-no.
Art.-no.
S30-1307C S30-1308C
S30-1307D
S30-1607D S30-1608D
S30-1607F
S30-1707D S30-1708D
S30-1707F
S30-1707G
S30-1707H
S30-1807D S30-1808D
S30-1807F
S30-1807G
S30-1807H
S30-1907D S30-1908D
S30-1907F S30-1908F
S30-1907G
S30-1907H
S30-2007D S30-2008D
S30-2007F S30-2008F
S30-2007G S30-2008G
S30-2007H
S30-2107D S30-2108D
S30-2107F S30-2108F
S30-2107G S30-2108G
S30-2107H S30-2108H
S30-2207D S30-2208D
S30-2207F S30-2208F
S30-2207G S30-2208G
S30-2207H

10P10
Art.-no.
S30-1309C
S30-1609D
S30-1709D

S30-1809D
S30-1809F

S30-1909D
S30-1909F

S30-2009D
S30-2009F
S30-2009G
S30-2109D
S30-2109F
S30-2109G
S30-2109H
S30-2209D
S30-2209F
S30-2209G

MBS AG

SASK 41.6
Protection plug-in current transformer
1A

Secondary current
Primary
current
A
100
150

200

250

300

400

500

600

Primary conductor
Round conductor
Transformer width
Snap-on mounting
Sealed shutter
Current transformer
for industrial applications
Current transformer for
tariff applications

Burden
VA
1.5
2.5
2.5
5
7,5
2.5
5
7.5
10
2.5
5
7.5
10
2.5
5
7.5
10
2.5
5
7.5
10
2.5
5
7.5
10
2.5
5
7.5
10

5P5
Art.-no.
S30-1316C
S30-1316D
S30-1616D
S30-1616F
S30-1716D
S30-1716F
S30-1716G
S30-1816D
S30-1816F
S30-1816G
S30-1816H
S30-1916D
S30-1916F
S30-1916G
S30-1916H
S30-2016D
S30-2016F
S30-2016G
S30-2016H
S30-2116D
S30-2116F
S30-2116G
S30-2116H
S30-2216D
S30-2216F
S30-2216G
S30-2216H

Protection class
10P5
5P10
Art.-no.
Art.-no.
S30-1317C S30-1318C
S30-1317D
S30-1617D S30-1618D
S30-1617F
S30-1617G
S30-1717D S30-1718D
S30-1717F
S30-1717G
S30-1717H
S30-1817D S30-1818D
S30-1817F S30-1818F
S30-1817G
S30-1817H
S30-1917D S30-1918D
S30-1917F S30-1918F
S30-1917G
S30-1917H
S30-2017D S30-2018D
S30-2017F S30-2018F
S30-2017G S30-2018G
S30-2017H
S30-2117D S30-2118D
S30-2117F S30-2118F
S30-2117G S30-2118G
S30-2117H S30-2118H
S30-2217D S30-2218D
S30-2217F S30-2218F
S30-2217G S30-2218G
S30-2217H

10P10
Art.-no.
S30-1319C
S30-1619D

S30-1719D

S30-1819D
S30-1819F

S30-1919D
S30-1919F

S30-2019D
S30-2019F
S30-2019G
S30-2119D
S30-2119F
S30-2119G
S30-2119H
S30-2219D
S30-2219F
S30-2219G

40 x 12 mm
30 x 15 mm
32 mm
95 mm

Art.-no. 59044
see page 205
see page 61
see page 176

www.mbs-stromwandler.de

135

MBS AG

SASK 41.10
Protection plug-in current transformer
5A

Secondary current
Primary
current
A
100

150

200

250

300

400

500

600

750

800

Primary conductor
Round conductor
Transformer width
Snap-on mounting
Sealed shutter

136

40 x 10 mm
32 mm
150 mm

www.mbs-stromwandler.de

Burden
VA
5
7.5
10
15
5
7.5
10
15
5
7.5
10
15
5
7.5
10
15
5
7.5
10
15
5
7.5
10
15
5
7.5
10
15
5
7.5
10
15
5
7.5
10
15
5
7.5
10
15

5P5
Art.-no.
S31-1306F
S31-1306G
S31-1306H
S31-1606F
S31-1606G
S31-1606H
S31-1606J
S31-1706F
S31-1706G
S31-1706H
S31-1706J
S31-1806F
S31-1806G
S31-1806H
S31-1806J
S31-1906F
S31-1906G
S31-1906H
S31-1906J
S31-2006F
S31-2006G
S31-2006H
S31-2006J
S31-2106F
S31-2106G
S31-2106H
S31-2106J
S31-2206F
S31-2206G
S31-2206H
S31-2206J
S31-2306F
S31-2306G
S31-2306H
S31-2306J
S31-2406F
S31-2406G
S31-2406H
S31-2406J

Protection class
10P5
5P10
Art.-no.
Art.-no.
S31-1307F
S31-1307G
S31-1307H
S31-1307J
S31-1607F
S31-1607G
S31-1607H
S31-1607J
S31-1707F S31-1708F
S31-1707G S31-1708G
S31-1707H
S31-1707J
S31-1807F S31-1808F
S31-1807G S31-1808G
S31-1807H S31-1808H
S31-1807J
S31-1907F S31-1908F
S31-1907G S31-1908G
S31-1907H S31-1908H
S31-1907J
S31-2007F S31-2008F
S31-2007G S31-2008G
S31-2007H S31-2008H
S31-2007J S31-2008J
S31-2107F S31-2108F
S31-2107G S31-2108G
S31-2107H S31-2108H
S31-2107J S31-2108J
S31-2207F S31-2208F
S31-2207G S31-2208G
S31-2207H S31-2208H
S31-2207J S31-2208J
S31-2307F S31-2308F
S31-2307G S31-2308G
S31-2307H S31-2308H
S31-2307J S31-2308J
S31-2407F S31-2408F
S31-2407G S31-2408G
S31-2407H S31-2408H
S31-2407J S31-2408J

10P10
Art.-no.
S31-1309F

S31-1709F
S31-1709G
S31-1709H
S31-1809F
S31-1809G
S31-1809H
S31-1809J
S31-1909F
S31-1909G
S31-1909H
S31-1909J
S31-2009F
S31-2009G
S31-2009H
S31-2009J
S31-2109F
S31-2109G
S31-2109H
S31-2109J
S31-2209F
S31-2209G
S31-2209H
S31-2209J
S31-2309F
S31-2309G
S31-2309H
S31-2309J
S31-2409F
S31-2409G
S31-2409H
S31-2409J

MBS AG

SASK 41.10
Protection plug-in current transformer
1A

Secondary current
Primary
current
A
100

150

200

250

300

400

500

600

750

800

Primary conductor
Round conductor
Transformer width
Snap-on mounting
Sealed shutter

Burden
VA
5
7.5
10
15
5
7.5
10
15
5
7.5
10
15
5
7.5
10
15
5
7.5
10
15
5
7.5
10
15
5
7.5
10
15
5
7.5
10
15
5
7.5
10
15
5
7.5
10
15

5P5
Art.-no.
S31-1316F
S31-1316G
S31-1316H
S31-1616F
S31-1616G
S31-1616H
S31-1616J
S31-1716F
S31-1716G
S31-1716H
S31-1716J
S31-1816F
S31-1816G
S31-1816H
S31-1816J
S31-1916F
S31-1916G
S31-1916H
S31-1916J
S31-2016F
S31-2016G
S31-2016H
S31-2016J
S31-2116F
S31-2116G
S31-2116H
S31-2116J
S31-2216F
S31-2216G
S31-2216H
S31-2216J
S31-2316F
S31-2316G
S31-2316H
S31-2316J
S31-2416F
S31-2416G
S31-2416H
S31-2416J

Protection class
10P5
5P10
Art.-no.
Art.-no.
S31-1317F
S31-1317G
S31-1317H
S31-1317J
S31-1617F
S31-1617G
S31-1617H
S31-1617J
S31-1717F S31-1718F
S31-1717G S31-1718G
S31-1717H
S31-1717J
S31-1817F S31-1818F
S31-1817G S31-1818G
S31-1817H S31-1818H
S31-1817J
S31-1917F S31-1918F
S31-1917G S31-1918G
S31-1917H S31-1918H
S31-1917J
S31-2017F S31-2018F
S31-2017G S31-2018G
S31-2017H S31-2018H
S31-2017J S31-2018J
S31-2117F S31-2118F
S31-2117G S31-2118G
S31-2117H S31-2118H
S31-2117J S31-2118J
S31-2217F S31-2218F
S31-2217G S31-2218G
S31-2217H S31-2218H
S31-2217J S31-2218J
S31-2317F S31-2318F
S31-2317G S31-2318G
S31-2317H S31-2318H
S31-2317J S31-2318J
S31-2417F S31-2418F
S31-2417G S31-2418G
S31-2417H S31-2418H
S31-2417J S31-2418J

10P10
Art.-no.
S31-1319F

S31-1619F

S31-1719F
S31-1719G
S31-1719H
S31-1819F
S31-1819G
S31-1819H
S31-1819J
S31-1919F
S31-1919G
S31-1919H
S31-1919J
S31-2019F
S31-2019G
S31-2019H
S31-2019J
S31-2119F
S31-2119G
S31-2119H
S31-2119J
S31-2219F
S31-2219G
S31-2219H
S31-2219J
S31-2319F
S31-2319G
S31-2319H
S31-2319J
S31-2419F
S31-2419G
S31-2419H
S31-2419J

40 x 10 mm
32 mm
150 mm

www.mbs-stromwandler.de

137

MBS AG

MBS AG

Protection plug-in current transformers


SASK 541.4

Primary conductor
Round conductor
Transformer width

SASK 51.4

Primary conductor
Round conductor
Transformer width

SASK 51.6

40 x 10
2 x 30 x 15
32
86

mm
mm
mm
mm

50 x 12
2 x 40 x 10
44
86

mm
mm
mm
mm

50 x 12
40 x 30
40
95

mm
mm
mm
mm

Primary conductor
Round conductor
Transformer width

www.mbs-stromwandler.de

139

MBS AG

SASK 541.4
Protection plug-in current transformer
5A

Secondary current
Primary
current
A
100
125

150
200
250
300

400

500

600

750

1000

Primary conductor

40 x 10 mm
2 x 30 x 5 mm
32 mm
86 mm

Art.-no. 59042
see page 205

Round conductor
Transformer width
Snap-on mounting
Sealed shutter
Current transformer
for industrial applications
Current transformer for
tariff applications

140

see page 64
see page 177

www.mbs-stromwandler.de

Burden
VA
1
1.5
1
1.5
2.5
1.5
2.5
1.5
2.5
1.5
2.5
1.5
2.5
5
1.5
2.5
5
1.5
2.5
5
7.5
1.5
2.5
5
7.5
2.5
5
7.5
2.5
5
7.5
10

5P5
Art.-no.
S33-1306B
S33-1306C
S33-1506B
S33-1506C
S33-1606C
S33-1606D
S33-1706C
S33-1706D
S33-1806C
S33-1806D
S33-1906C
S33-1906D
S33-2006C
S33-2006D
S33-2006F
S33-2106C
S33-2106D
S33-2106F
S33-2206C
S33-2206D
S33-2206F
S33-2306D
S33-2306F
S33-2306G
S33-2506D
S33-2506F
S33-2506G
S33-2506H

Protection class
10P5
5P10
Art.-no.
Art.-no.
S33-1307B
S33-1307C
S33-1507B
S33-1507C
S33-1507D
S33-1607C
S33-1607D
S33-1707C
S33-1707D
S33-1807C
S33-1807D
S33-1907C S33-1908C
S33-1907D
S33-1907F
S33-2007C S33-2008C
S33-2007D
S33-2007F
S33-2107C S33-2108C
S33-2107D S33-2108D
S33-2107F
S33-2107G
S33-2207C S33-2208C
S33-2207D S33-2208D
S33-2207F
S33-2207G
S33-2307D S33-2308D
S33-2307F
S33-2307G
S33-2507D S33-2508D
S33-2507F
S33-2507G
S33-2507H

10P10
Art.-no.

S33-1809C
S33-1909C

S33-2009C

S33-2109C
S33-2109D

S33-2209C
S33-2209D

S33-2309D

S33-2509D

MBS AG

SASK 541.4
Protection plug-in current transformer
1A

Secondary current
Primary
current
A
100
125

150
200
250
300

400

500

600

750

1000

Primary conductor
Round conductor
Transformer width
Snap-on mounting
Sealed shutter
Current transformer
for industrial applications
Current transformer for
tariff applications

Burden
VA
1
1,5
1
1,5
2,5
1,5
2,5
1,5
2,5
1,5
2,5
1,5
2,5
5
1,5
2,5
5
1,5
2,5
5
1,5
2,5
5
7,5
1,5
2,5
5
7,5
2,5
5
7,5
10

5P5
Art.-no.
S33-1316B
S33-1316C
S33-1516B
S33-1516C
S33-1516D
S33-1616C
S33-1616D
S33-1716C
S33-1716D
S33-1816C
S33-1816D
S33-1916C
S33-1916D
S33-2016C
S33-2016D
S33-2016F
S33-2116C
S33-2116D
S33-2116F
S33-2216C
S33-2216D
S33-2216F
S33-2316C
S33-2316D
S33-2316F
S33-2316G
S33-2516D
S33-2516F
S33-2516G
S33-2516H

Protection class
10P5
5P10
Art.-no.
Art.-no.
S33-1317B
S33-1317C
S33-1517B
S33-1517C
S33-1517D
S33-1617C
S33-1617D
S33-1717C
S33-1717D
S33-1817C S33-1818C
S33-1817D
S33-1917C S33-1918C
S33-1917D
S33-1917F
S33-2017C S33-2018C
S33-2017D
S33-2017F
S33-2117C S33-2118C
S33-2117D S33-2118D
S33-2117F
S33-2217C S33-2218C
S33-2217D S33-2218D
S33-2217F
S33-2217G
S33-2317C S33-2318C
S33-2317D S33-2318D
S33-2317F
S33-2317G
S33-2517D S33-2518D
S33-2517F
S33-2517G
S33-2517H

10P10
Art.-no.

S33-1819C
S33-1919C

S33-2019C

S33-2119C
S33-2119D
S33-2219C
S33-2219D

S33-2319C
S33-2319D

S33-2519D
S33-2519F

40 x 10 mm
2 x 30 x 5 mm
32 mm
86 mm

Art.-no. 59042
see page 205
see page 64
see page 177

www.mbs-stromwandler.de

141

MBS AG

SASK 51.4
Protection plug-in current transformer
Secondary current
Primary
current
A
150
200
250
300
400
500
600
750

1000

Primary conductor

50 x 12 mm
2 x 40 x 10 mm
44 mm
86 mm

Art.-no. 59042
see page 205

Round conductor
Transformer width
Snap-on mounting
Sealed shutter
Current transformer
for industrial applications
Current transformer for
tariff applications

142

see page 65
see page 178

www.mbs-stromwandler.de

Burden
VA
1
1
1.5
1.5
2.5
1.5
2.5
1.5
2.5
1.5
2.5
1.5
2.5
1.5
2.5
5
1.5
2.5
5

5A
Protection class
5P5
10P5
Art.-no.
Art.-no.
S34-1706B S34-1707B
S34-1707C
S34-1806C S34-1807C
S34-1906C S34-1907C
S34-2006C S34-2007C
S34-2007D
S34-2106C S34-2107C
S34-2107D
S34-2206C S34-2207C
S34-2207D
S34-2306C S34-2307C
S34-2306D S34-2307D
S34-2506C S34-2507C
S34-2506D S34-2507D

1A
Protection class
5P5
10P5
Art.-no.
Art.-no.
S34-1616B S34-1617B
S34-1716B S34-1717B
S34-1716C S34-1717C
S34-1816C S34-1817C
S34-1817D
S34-1916C S34-1917C
S34-1916D S34-1917D
S34-2016C S34-2017C
S34-2016D S34-2017D
S34-2116C S34-2117C
S34-2116D S34-2117D
S34-2216C S34-2217C
S34-2216D S34-2217D
S34-2316C S34-2317C
S34-2316D S34-2317D
S34-2317F
S34-2516C S34-2517C
S34-2516D S34-2517D
S34-2516F S34-2517F

MBS AG

MBS AG

SASK 51.6
Protection plug-in current transformer
5A

Secondary current
Primary
current
A
150
200

250

300

400

500

600

750

1000

Primary conductor

50 x 12 mm
40 x 30 mm
40 mm
95 mm

Art.-no. 59044
see page 205

Round conductor
Transformer width
Snap-on mounting
Sealed shutter
Current transformer
for industrial applications
Current transformer for
tariff applications

144

see page 67
see page 179

www.mbs-stromwandler.de

Burden
VA
1.5
2.5
1.5
2.5
5
2.5
5
7.5
2.5
5
7.5
2.5
5
7.5
2.5
5
7.5
10
2.5
5
7.5
10
2.5
5
7.5
10
2.5
5
7.5
10

5P5
Art.-no.
S37-1606C
S37-1606D
S37-1706C
S37-1706D
S37-1706F
S37-1806D
S37-1806F
S37-1906D
S37-1906F
S37-1906G
S37-2006D
S37-2006F
S37-2006G
S37-2106D
S37-2106F
S37-2106G
S37-2106H
S37-2206D
S37-2206F
S37-2206G
S37-2206H
S37-2306D
S37-2306F
S37-2306G
S37-2306H
S37-2506D
S37-2506F
S37-2506G
S37-2506H

Protection class
10P5
5P10
Art.-no.
Art.-no.
S37-1607C S37-1608C
S37-1607D
S37-1707C S37-1708C
S37-1707D
S37-1707F
S37-1807D S37-1808D
S37-1807F
S37-1807G
S37-1907D S37-1908D
S37-1907F
S37-1907G
S37-2007D S37-2008D
S37-2007F
S37-2007G
S37-2107D S37-2108D
S37-2107F
S37-2107G
S37-2107H
S37-2207D S37-2208D
S37-2207F
S37-2207G
S37-2207H
S37-2307D S37-2308D
S37-2307F S37-2308F
S37-2307G
S37-2307H
S37-2507D S37-2508D
S37-2507F S37-2508F
S37-2507G
S37-2507H

10P10
Art.-no.
S37-1609C
S37-1709C

S37-1809D

S37-1909D

S37-2009D

S37-2109D

S37-2209D

S37-2309D
S37-2309F

S37-2509D
S37-2509F

MBS AG

SASK 51.6
Protection plug-in current transformer
1A

Secondary current
Primary
current
A
150
200

250

300

400

500

600

750

1000

Primary conductor
Round conductor
Transformer width
Snap-on mounting
Sealed shutter
Current transformer
for industrial applications
Current transformer for
tariff applications

Burden
VA
1.5
2.5
1.5
2.5
5
2.5
5
7.5
2.5
5
7.5
2.5
5
7.5
2.5
5
7.5
10
2.5
5
7.5
10
2.5
5
7.5
10
2.5
5
7.5
10

5P5
Art.-no.
S37-1616C
S37-1616D
S37-1716C
S37-1716D
S37-1716F
S37-1816D
S37-1816F
S37-1916D
S37-1916F
S37-2016D
S37-2016F
S37-2016G
S37-2116D
S37-2116F
S37-2116G
S37-2116H
S37-2216D
S37-2216F
S37-2216G
S37-2216H
S37-2316D
S37-2316F
S37-2316G
S37-2316H
S37-2516D
S37-2516F
S37-2516G
S37-2516H

Protection class
10P5
5P10
Art.-no.
Art.-no.
S37-1617C S37-1618C
S37-1617D
S37-1717C S37-1718C
S37-1717D S37-1718D
S37-1717F
S37-1817D S37-1818D
S37-1817F
S37-1817G
S37-1917D S37-1918D
S37-1917F
S37-1917G
S37-2017D S37-2018D
S37-2017F
S37-2017G
S37-2117D S37-2118D
S37-2117F
S37-2117G
S37-2117H
S37-2217D S37-2218D
S37-2217F S37-2218F
S37-2217G
S37-2217H
S37-2317D S37-2318D
S37-2317F S37-2318F
S37-2317G
S37-2317H
S37-2517D S37-2518D
S37-2517F S37-2518F
S37-2517G
S37-2517H

10P10
Art.-no.
S37-1619C
S37-1719C
S37-1719D
S37-1819D

S37-1919D

S37-2019D

S37-2119D
S37-2119F

S37-2219D
S37-2219F

S37-2319D
S37-2319F

S37-2519D
S37-2519F

50 x 12 mm
40 x 30 mm
40 mm
95 mm

Art.-no. 59044
see page 205
see page 67
see page 179

www.mbs-stromwandler.de

145

MBS AG

MBS AG

Protection plug-in current transformers


SASK 61.4

Primary conductor
Round conductor
Transformer width

SASK 61.10

60 x 10
2 x 50 x 10
44
96

Primary conductor

mm
mm
mm
mm

Transformer width

60 x 10 mm
50 x 30 mm
150 mm

SASK 63.6

Primary conductor
Round conductor
Transformer width

60 x 30 mm
30 mm
88 mm

SASK 105.6

Primary conductor
Round conductor
Transformer width

100 x 55 mm
55 mm
129 mm

www.mbs-stromwandler.de

147

MBS AG

SASK 61.4
Protection plug-in current transformer
Secondary current
Primary
current
A
200
250
300
400
500
600

750

1000

1200

1250

Primary conductor

63 x 10 mm
2 x 50 x 10 mm
44 mm
96 mm

Art.-no. 59042
see page 205

Round conductor
Transformer width
Snap-on mounting
Sealed shutter
Current transformer
for industrial applications
Current transformer for
tariff applications

148

see page 70
see page 182

www.mbs-stromwandler.de

5A

Protection class
Burden
5P5
10P5
VA
Art.-no.
Art.-no.
1
S41-1706B S41-1707B
1.5
S41-1706C S41-1707C
1
S41-1806B S41-1807B
1.5
S41-1806C S41-1807C
1.5
S41-1906C S41-1907C
2.5
S41-1907D
1.5
S41-2006C S41-2007C
2.5
S41-2006D S41-2007D
1.5
S41-2106C S41-2107C
2.5
S41-2106D S41-2107D
1.5
S41-2206C S41-2207C
2.5
S41-2206D S41-2207D
5
1.5
S41-2306C S41-2307C
2.5
S41-2306D S41-2307D
5
S41-2307F S41-2307F
1.5
S41-2506C S41-2507C
2.5
S41-2506D S41-2507D
5
S41-2506F S41-2507F
1.5
S41-2606C S41-2607C
2.5
S41-2606D S41-2607D
5
S41-2606F S41-2607F
1.5
S41-2706C S41-2707C
2.5
S41-2706D S41-2707D
5
S41-2706F S41-2707F

1A
Protection class
5P5
10P5
Art.-no.
Art.-no.
S41-1716B S41-1717B
S41-1716C S41-1717C
S41-1816B S41-1817B
S41-1816C S41-1817C
S41-1916C S41-1917C
S41-1916D S41-1917D
S41-2016C S41-2017C
S41-2016D S41-2017D
S41-2116C S41-2117C
S41-2116D S41-2117D
S41-2216C S41-2217C
S41-2216D S41-2217D
S41-2216F S41-2217F
S41-2316C S41-2317C
S41-2316D S41-2317D
S41-2316F S41-2317F
S41-2516C S41-2517C
S41-2516D S41-2517D
S41-2516F S41-2517F
S41-2616C S41-2617C
S41-2616D S41-2617D
S41-2616F S41-2617F
S41-2716C S41-2717C
S41-2716D S41-2717D
S41-2716F S41-2717F

MBS AG

MBS AG

SASK 61.10
Protection plug-in current transformer
5A

Secondary current
Primary
current
A
250

300

400

500

600

750

1000

1200

1250

1500

2000

Primary conductor
Round conductor
Transformer width
Snap-on mounting
Sealed shutter

150

60 x 10 mm
50 x 30 mm

150 mm

www.mbs-stromwandler.de

Burden
VA
5
7.5
10
5
7.5
10
15
5
7.5
10
15
5
7.5
10
15
5
7.5
10
15
5
7.5
10
15
5
7.5
10
15
5
7.5
10
15
5
7.5
10
15
5
7.5
10
15
5
7.5
10
15

5P5
Art.-no.
S50-1806F
S50-1806G
S50-1806H
S50-1906F
S50-1906G
S50-1906H
S50-1906J
S50-2006F
S50-2006G
S50-2006H
S50-2006J
S50-2106F
S50-2106G
S50-2106H
S50-2106J
S50-2206F
S50-2206G
S50-2206H
S50-2206J
S50-2306F
S50-2306G
S50-2306H
S50-2306J
S50-2506F
S50-2506G
S50-2506H
S50-2506J
S50-2606F
S50-2606G
S50-2606H
S50-2606J
S50-2706F
S50-2706G
S50-2706H
S50-2706J
S50-2806F
S50-2806G
S50-2806H
S50-2806J
S50-3006F
S50-3006G
S50-3006H
S50-3006J

Protection class
10P5
5P10
Art.-no.
Art.-no.
S50-1807F S50-1808F
S50-1807G
S50-1807H
S50-1907F S50-1908F
S50-1907G S50-1908G
S50-1907H
S50-1907J
S50-2007F S50-2008F
S50-2007G S50-2008G
S50-2007H S50-2008H
S50-2007J
S50-2107F S50-2108F
S50-2107G S50-2108G
S50-2107H S50-2108H
S50-2107J S50-2108J
S50-2207F S50-2208F
S50-2207G S50-2208G
S50-2207H S50-2208H
S50-2207J S50-2208J
S50-2307F S50-2308F
S50-2307G S50-2308G
S50-2307H S50-2308H
S50-2307J S50-2308J
S50-2507F S50-2508F
S50-2507G S50-2508G
S50-2507H S50-2508H
S50-2507J S50-2508J
S50-2607F S50-2608F
S50-2607G S50-2608G
S50-2607H S50-2608H
S50-2607J S50-2608J
S50-2707F S50-2708F
S50-2707G S50-2708G
S50-2707H S50-2708H
S50-2707J S50-2708J
S50-2807F S50-2808F
S50-2807G S50-2808G
S50-2807H S50-2808H
S50-2807J S50-2808J
S50-3007F S50-3008F
S50-3007G S50-3008G
S50-3007H S50-3008H
S50-3007J S50-3008J

10P10
Art.-no.
S50-1809F
S50-1809G
S50-1909F
S50-1909G
S50-1909H
S50-2009F
S50-2009G
S50-2009H
S50-2009J
S50-2109F
S50-2109G
S50-2109H
S50-2109J
S50-2209F
S50-2209G
S50-2209H
S50-2209J
S50-2309F
S50-2309G
S50-2309H
S50-2309J
S50-2509F
S50-2509G
S50-2509H
S50-2509J
S50-2609F
S50-2609G
S50-2609H
S50-2609J
S50-2709F
S50-2709G
S50-2709H
S50-2709J
S50-2809F
S50-2809G
S50-2809H
S50-2809J
S50-3009F
S50-3009G
S50-3009H
S50-3009J

MBS AG

SASK 61.10
Protection plug-in current transformer
1A

Secondary current
Primary
current
A
250

300

400

500

600

750

1000

1200

1250

1500

2000

Primary conductor
Round conductor
Transformer width
Snap-on mounting
Sealed shutter

Burden
VA
5
7.5
10
5
7.5
10
15
5
7.5
10
15
5
7.5
10
15
5
7.5
10
15
5
7.5
10
15
5
7.5
10
15
5
7.5
10
15
5
7.5
10
15
5
7.5
10
15
5
7.5
10
15

5P5
Art.-no.
S50-1816F
S50-1816G
S50-1816H
S50-1916F
S50-1916G
S50-1916H
S50-1916J
S50-2016F
S50-2016G
S50-2016H
S50-2016J
S50-2116F
S50-2116G
S50-2116H
S50-2116J
S50-2216F
S50-2216G
S50-2216H
S50-2216J
S50-2316F
S50-2316G
S50-2316H
S50-2316J
S50-2516F
S50-2516G
S50-2516H
S50-2516J
S50-2616F
S50-2616G
S50-2616H
S50-2616J
S50-2716F
S50-2716G
S50-2716H
S50-2716J
S50-2816F
S50-2816G
S50-2816H
S50-2816J
S50-3016F
S50-3016G
S50-3016H
S50-3016J

Protection class
10P5
5P10
Art.-no.
Art.-no.
S50-1817F S50-1818F
S50-1817G
S50-1817H
S50-1917F S50-1918F
S50-1917G S50-1918G
S50-1917H
S50-1917J
S50-2017F S50-2018F
S50-2017G S50-2018G
S50-2017H S50-2018H
S50-2017J
S50-2117F S50-2118F
S50-2117G S50-2118G
S50-2117H S50-2118H
S50-2117J S50-2118J
S50-2217F S50-2218F
S50-2217G S50-2218G
S50-2217H S50-2218H
S50-2217J S50-2218J
S50-2317F S50-2318F
S50-2317G S50-2318G
S50-2317H S50-2318H
S50-2317J S50-2318J
S50-2517F S50-2518F
S50-2517G S50-2518G
S50-2517H S50-2518H
S50-2517J S50-2518J
S50-2617F S50-2618F
S50-2617G S50-2618G
S50-2617H S50-2618H
S50-2617J S50-2618J
S50-2717F S50-2718F
S50-2717G S50-2718G
S50-2717H S50-2718H
S50-2717J S50-2718J
S50-2817F S50-2818F
S50-2817G S50-2818G
S50-2817H S50-2818H
S50-2817J S50-2818J
S50-3017F S50-3018F
S50-3017G S50-3018G
S50-3017H S50-3018H
S50-3017J S50-3018J

10P10
Art.-no.
S50-1819F
S50-1819G
S50-1919F
S50-1919G
S50-1919H
S50-2019F
S50-2019G
S50-2019H
S50-2019J
S50-2119F
S50-2119G
S50-2119H
S50-2119J
S50-2219F
S50-2219G
S50-2219H
S50-2219J
S50-2319F
S50-2319G
S50-2319H
S50-2319J
S50-2519F
S50-2519G
S50-2519H
S50-2519J
S50-2619F
S50-2619G
S50-2619H
S50-2619J
S50-2719F
S50-2719G
S50-2719H
S50-2719J
S50-2819F
S50-2819G
S50-2819H
S50-2819J
S50-3019F
S50-3019G
S50-3019H
S50-3019J

60 x 10 mm
50 x 30 mm

150 mm

www.mbs-stromwandler.de

151

MBS AG

SASK 63.6
Protection plug-in current transformer
Secondary current
Primary
current
A
200
250
300
400
500
600
750
1000

Primary conductor
Round conductor
Transformer width
Snap-on mounting
Sealed shutter

60 x 30 mm
30 mm
88 mm

Art.-no. 59042
see page 205

Current transformer
for industrial applications
Current transformer for
tariff applications

152

see page 74
see page 184

www.mbs-stromwandler.de

5A

Protection class
Burden
5P5
10P5
VA
Art.-no.
Art.-no.
1.5
S46-1706C S17-1707C
2.5
S46-1707D
1.5
S46-1806C S46-1807C
2.5
S46-1806D S46-1807D
1.5
S46-1906C S46-1907C
2.5
S46-1906D S46-1907D
2.5
S46-2006D S46-2007D
5
S46-2007F
2.5
S46-2106D S46-2107D
5
S46-2106F S46-2107F
2.5
S46-2206D S46-2207D
5
S46-2206F S46-2207F
2.5
S46-2306D S46-2307D
5
S46-2306F S46-2307F
2.5
S46-2506D S46-2507D
5
S46-2506F S46-2507F

1A
Protection class
5P5
10P5
Art.-no.
Art.-no.
S46-1716C S46-1717C
S46-1716D S46-1717D
S46-1816C S46-1817C
S46-1816D S46-1817D
S46-1916C S46-1917C
S46-1916D S46-1917D
S46-2016D S46-2017D
S46-2016F S46-2017F
S46-2116D S46-2117D
S46-2116F S46-2117F
S46-2216D S46-2217D
S46-2216F S46-2217F
S46-2316D S46-2317D
S46-2316F S46-2317F
S46-2516D S46-2517D
S46-2516F S46-2517F

MBS AG

SASK 105.6
Protection plug-in current transformer
Secondary current
Primary
current
A
600
750

1000

1200

1250

1500

1600

Primary conductor
Round conductor
Transformer width
Snap-on mounting
Sealed shutter
Current transformer
for industrial applications
Current transformer for
tariff applications

5A

Protection class
Burden
5P5
10P5
VA
Art.-no.
Art.-no.
2.5
S56-2206C S56-2207C
5
S56-2206F S56-2207F
2.5
S56-2306C S56-2307C
5
S56-2306F S56-2307F
10
S56-2307H
5
S56-2506F S56-2507F
10
S56-2506H S56-2507H
15
5
S56-2606F S56-2607F
10
S56-2606H S26-2607H
15
S26-2607J
5
S56-2706F S56-2707F
10
S56-2706H S56-2707H
15
S56-2706J S56-2707J
5
S56-2806F S56-2807F
10
S56-2806H S56-2807H
15
S56-2806J S56-2807J
10
S56-2906H S56-2907H
15
S56-2906J S56-2907J

1A
Protection class
5P5
10P5
Art.-no.
Art.-no.
S56-2216C S56-2217C
S56-2216F S56-2217F
S56-2316C S56-2317C
S56-2316F S56-2317F
S56-2316H S56-2317H
S56-2516F S56-2517F
S56-2516H S56-2517H
S56-2517J
S56-2616F S56-2617F
S56-2616H S56-2617H
S56-2616J S56-2617J
S56-2716F S56-2717F
S56-2716H S56-2717H
S56-2716J S56-2717J
S56-2816F S56-2817F
S56-2816H S56-2817H
S56-2816J S56-2817J
S56-2916H S56-2917H
S56-2916J S59-2917J

100 x 55 mm
55 mm
129 mm

Art.-no. 59042
see page 205
see page 86
see page 188

www.mbs-stromwandler.de

153

MBS AG

Three-phase current transformer sets

www.mbs-stromwandler.de

MBS AG

Three-phase current transformer sets


ASRD 14

Primary conductor
Transformer width

3 x 13.5 mm
105 mm

for standard rail mounting

ASRD 210.3

Primary conductor
Transformer width

3 x 21.5 mm
49.6 mm

Slim-Line-rail

ASK(D) 21.3

with Plexiglas caps

ASK(D) 31.5
ASK(D) 31.5 2U

with Plexiglas caps

WSKD 31.8
ASKD 31.8

with Plexiglas caps

www.mbs-stromwandler.de

155

MBS AG

ASRD 14
Three-phase current transformer set
Secondary current
Primary
current
A
3 x 50
3 x 60
3 x 75
3 x 80
3 x 100
3 x 125
3 x 150

Primary conductor
Round conductor
Transformer width
Snap-on mounting
Sealed shutter

156

3 x 13.5 mm
105 mm
integrated

www.mbs-stromwandler.de

Burden
VA
1
1.25
1.5
1.5
2.5
2.5
3.75
2.5
3.75

5A

1A

Accuracy class
1
0.5
Art.-no. Art.-no.
96030
96032
96034
96036
96038
96012
96039
96014
96041
96040
96017
96044

Accuracy class
1
0.5
Art.-no. Art.-no.
96230
96232
96234
96236
96238
96212
96214
96241
96217
96244

MBS AG

ASRD 210.3
Three-phase current transformer set
Secondary current
Primary
current
A
50
60
75
80
100
125

150

160
200

250

300

Primary conductor
Round conductor
Transformer width
Snap-on mounting
Sealed shutter

Burden
VA
1
1
1.25
1.25
1.5
1.25
1.5
1.5
2.5
1.5
2.5
3.75
1.5
2.5
3.75
5
1.5
2.5
5
2.5
5
7.5
2.5
5
7.5

5A

1A

Accuracy class
1
0.5
Art.-no. Art.-no.
27700
27701
27702
27703
27704
27705
27706
27707
27726
27708
27724
27709
27710
27711
27712
27713
27725
27714
27750
27715
27716
27717
27718
27719
27720
27721
27722
27723

Accuracy class
1
0.5
Art.-no. Art.-no.
27800
27801
27802
27803
27804
27805
27806
27807
27808
27824
27809
27810
27811
27812
27813
27825
27814
27815
27816
27817
27818
27819
27820
27821
27822
27823

3 x 21.5 mm
49.6 mm

www.mbs-stromwandler.de

157

MBS AG

Three-phase current transformer set


ASK(D) 21.3
with Plexiglas caps

Configuration:
The measuring transformer set consists of 3 individual current transformers which are mounted on an
aluminium base plate together with the primary conductors L1, L2, L3 and neutral conductor.
The current transformer set can be supplied with or without fuses. The voltage supply is optional
and can be tapped either from the 10 A-NEOZED fuse or from the individual primary conductors.
Transparent, sealable covers protect the secondary terminals of the current transformers against external
tampering. All voltage carrying parts of the assembled current transformer set are made shock-proof with
isolating covers which are included in the deliveries.
Flexible copper wire with a nominal cross section of 16 mm2 up to 70 mm2 can be connected to the
primary connection terminals.
The configuration of this current transformer set conforms to the technical requirements and guidance:
DIN EN 60044/1
DIN 42600
VBG 4

158

www.mbs-stromwandler.de

MBS AG

ASK(D) 21.3
Three-phase current transformer set
Secondary current
Primary
current
A
3 x 100
3 x 150

3 x 200

3 x 250

3 x 300

Burden
VA
1.5
2.5
1.5
2.5
5
1.5
2.5
5
1.5
2.5
5
2.5
5
10

5A

1A

Accuracy class
1
0.5
Art.-no. Art.-no.
56027
56011
56028
56012
56029
56013
56030
56014
56043
56015
56031
56016
56032
56017
56033
56018
56034
56019
56035
56020
56036
56021
56037
56022
56038
56023
56039

Accuracy class
1
0.5
Art.-no. Art.-no.
56227
56211
56228
56212
56229
56213
56230
56214
56243
56215
56231
56216
56232
56217
56233
56218
56234
56219
56235
56220
56236
56221
56237
56222
56238
56223
56239

www.mbs-stromwandler.de

159

MBS AG

Three-phase current transformer set


ASK(D) 31.5
ASK(D) 31.5 2U
with Plexiglas caps

Configuration:
The measuring transformer set consists of 3 individual current transformers which are mounted on an
aluminium base plate together with the primary conductors L1, L2, L3. Transparent sealable covers protect the secondary terminals of the current transformers against external tampering.
Stipulation of the VBG4 (German protection clause) demands that all voltage carrying parts are made
shock-proof with transparent isolating covers which are included in the deliveries.
As an option the current transformer set can be supplied with or without fuses. The voltage can be
tapped either from the 10 A-fuse element or directly from the individual primary conductor.
The configuration of this current transformer set conforms to:
DIN VDE 0414/1
DIN 42600 IEC 185
VBG 4

160

www.mbs-stromwandler.de

MBS AG

ASK(D) 31.5
Three-phase current transformer set
Secondary current
Primary
current
A
3 x 75
3 x 100
3 x 150
3 x 200

3 x 250

3 x 300

3 x 400

3 x 500

3 x 600

3 x 750

Burden
VA
2.5
2.5
5
2.5
5
2.5
5
10
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15

5A

1A

Accuracy class
1
0.5
Art.-no. Art.-no.
57043
57011
57044
57012
57045
57013
57046
57014
57047
57015
57048
57016
57049
57017
57050
57018
57051
57019
57052
57020
57053
57021
57054
57022
57055
57023
57056
57024
57057
57025
57058
57026
57059
57027
57060
57028
57061
57029
57062
57030
57063
57031
57064
57032
57065
57033
57066
57034
57067
57035
57068
57036
57069
57037
57070
57038
57071
57039
57072
57040
57073
57041
57074
57042

Accuracy class
1
0.5
Art.-no. Art.-no.
57243
57211
57244
57212
57245
57213
57246
57214
57247
57215
57248
57216
57249
57217
57250
57218
57251
57219
57252
57220
57253
57221
57254
57222
57255
57223
57256
57224
57257
57225
57258
57226
57259
57227
57260
57228
57261
57229
57262
57230
57263
57231
57264
57232
57265
57233
57266
57234
57267
57235
57268
57236
57269
57237
57270
57238
57271
57239
57272
57240
57273
57241
57274
57242

ASK(D) 31.5 2U
Secondary current
Primary
current
A
3 x 200-100
3 x 300-150
3 x 400-200
3 x 500-250
3 x 600-300

Burden
VA
5-2.5
10-5
5-2.5
10-5
5-2.5
10-5
5-2.5
10-5
5-2.5
10-5

5A

1A

Accuracy class
1
0.5
Art.-no. Art.-no.
57090
57080
57091
57081
57092
57082
57093
57083
57094
57084
57095
57085
57096
57086
57097
57087
57098
57088
57099
57089

Accuracy class
1
0.5
Art.-no. Art.-no.
57290
57280
57291
57281
57292
57282
57293
57283
57294
57284
57295
57285
57296
57286
57297
57287
57298
57288
57299
57289

www.mbs-stromwandler.de

161

MBS AG

Three-phase current transformer sets


WSKD 31.8
ASKD 31.8
with Plexiglas caps

Configuration:
The measuring transformer set of the WSKD 31.8 / ASKD 31.8 conform to the following standards:
DIN EN 60044/1
DIN 42600
VBG 4.
Mounted in housing units, are the current transformer sets, consisting of 3 identical individual current
transformers, fitted on a metalic base plate made of aluminium with a neutral conductor. The WSKD 31.8
is produced as a wound current transformer with 3 fixed primary windings for primary currents up to 150 A.
The ASKD 31.8 with primary nominal currents from 200 A are supplied with primary bus bars.
The current transformer set can be supplied with or without fuses. The voltage supply is optional
and can be tapped either from the 10 A-fuse element or directly from the individual primary conductor.
With 4 mm bore-holes arranged within the secondary connection terminals, a short circuit of the secondary circuit is made possible, when interchanging energy meters. The transformer set can be supplied with
or without a base plate (without a base plate there is no neutral conductor rail). All voltage carrying parts
of the assembled current transformer sets are made shock-proof with isolating covers which are included
in the deliveries.
General technical details:
Max. permitted operating voltage:
Rated frequency:
Over current rated limiting factor:
Thermal rated continuous current intensity:
Thermal rated short time current:
Isolation class:

162

www.mbs-stromwandler.de

0.72 kV
50 Hz
FS 5
1.2 x IN
50 x IN (WSKD 31.8)
60 x IN (ASKD 31.8)
E

MBS AG

WSKD 31.8
Three-phase current transformer set
with base plate
Secondary current
Primary
current
A
3 x 50

3 x 75

3 x 100

3 x 150

Burden
VA
2.5
5
10
2.5
5
10
2.5
5
10
2.5
5
10

5A

1A

Accuracy class
1
0.5
Art.-no. Art.-no.
44030
44011
44031
44012
44032
44013
44034
44015
44035
44016
44036
44017
44038
44019
44039
44020
44040
44021
44042
44023
44043
44024
44044
44025

Accuracy class
1
0.5
Art.-no. Art.-no.
44230
44211
44231
44212
44232
44213
44234
44215
44235
44216
44236
44217
44238
44219
44239
44220
44240
44221
44242
44223
44243
44224
44244
44225

without base plate and neutral conductor


Secondary current
Primary
current
A
3 x 50

3 x 75

3 x 100

3 x 150

Burden
VA
2.5
5
10
2.5
5
10
2.5
5
10
2.5
5
10

5A

1A

Accuracy class
1
0.5
Art.-no. Art.-no.
45030
45011
45031
45012
45032
45013
45034
45015
45035
45016
45036
45017
45038
45019
45039
45020
45040
45021
45042
45023
45043
45024
45044
45025

Accuracy class
1
0.5
Art.-no. Art.-no.
45230
45211
45231
45212
45232
45213
45234
45215
45235
45216
45236
45217
45238
45219
45239
45220
45240
45221
45242
45223
45243
45224
45244
45225

www.mbs-stromwandler.de

163

MBS AG

ASKD 31.8
Three-phase current transformer set
with base plate
Secondary current
Primary
current
A
3 x 200

3 x 250

3 x 300

3 x 400

3 x 500

3 x 600

Burden
VA
2.5
5
10
2.5
5
10
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15

5A

1A

Accuracy class
1
0.5
Art.-no. Art.-no.
46041
46011
46042
46012
46043
46013
46045
46015
46046
46016
46047
46017
46049
46019
46050
46020
46051
46021
46052
46022
46053
46023
46054
46024
46055
46025
46056
46026
46058
46028
46059
46029
46060
46030
46061
46031
46063
46033
46064
46034
46065
46035
46066
46036

Accuracy class
1
0.5
Art.-no. Art.-no.
46241
46211
46242
46212
46243
46213
46245
46215
46246
46216
46247
46217
46249
46219
46250
46220
46251
46221
46252
46222
46253
46223
46254
46224
46255
46225
46256
46226
46258
46228
46259
46229
46260
46230
46261
46231
46263
46233
46264
46234
46265
46235
46266
46236

without base plate and neutral conductor


Secondary current
Primary
current
A
3 x 200

3 x 250

3 x 300

3 x 400

3 x 500

3 x 600

164

www.mbs-stromwandler.de

Burden
VA
2.5
5
10
2.5
5
10
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15

5A

1A

Accuracy class
1
0.5
Art.-no. Art.-no.
47041
47011
47042
47012
47043
47013
47045
47015
47046
47016
47047
47017
47049
47019
47050
47020
47051
47021
47052
47022
47053
47023
47054
47024
47055
47025
47056
47026
47058
47028
47059
47029
47060
47030
47061
47031
47063
47033
47064
47034
47065
47035
47066
47036

Accuracy class
1
0.5
Art.-no. Art.-no.
47241
47211
47242
47212
47243
47213
47245
47215
47246
47216
47247
47217
47249
47219
47250
47220
47251
47221
47252
47222
47253
47223
47254
47224
47255
47225
47256
47226
47258
47228
47259
47229
47260
47230
47261
47231
47263
47233
47264
47234
47265
47235
47266
47236

MBS AG

Low voltage current transformers


for tariff applications
Tube current transformers
EASR 14.3

Round conductor
Transformer width

14 mm
61 mm

EASR 22.3

Round conductor
Transformer width

22.5 mm
61 mm

Plug-in current transformers


EASK 21.3

Primary conductor
Round conductor
Transformer width

EASK 31.3

Primary conductor
Round conductor
Transformer width

EASK 31.4

Primary conductor
Round conductor
Transformer width

EASK 31.5
EASK 31.5 2U

Primary conductor

EASK 31.6

Primary conductor

Round conductor
Transformer width

20 x 10 mm
19.2 mm
61 mm

30 x 10
2 x 20 x 10
26
61

mm
mm
mm
mm

30 x 10
2 x 20 x 10
28
61

mm
mm
mm
mm

30 x 10
2 x 20 x 10
28
61

mm
mm
mm
mm

30 x 10
20 x 13
23
95

mm
mm
mm
mm

Round conductor
Transformer width

Type E denotes that the current transformers are suitable for calibration
www.mbs-stromwandler.de

165

MBS AG

EASR 14.3
Tube current transformer

Secondary current
Primary
current
A
75
80
100
120
125
150

Burden
VA
1.5
1.5
1.5
1.5
2.5
1.5
2.5
1.5
2.5

5A
Accuracy class
0.5
0.5s
Art.-no. Art.-no.
26584
26590
26585
26591
26586
26592
26587
26593
26588
26594
26599
26595
26560
26597
26561
26598
26589
26596

Snap-on mounting

Primary conductor
Round conductor
Transformer width
Snap-on mounting
Sealed shutter
Current transformer for
industrial applications

166

14.0 mm
45 mm
Art.-no. 55013
see page 204
see page 205
see page 30

www.mbs-stromwandler.de

1A
0.2
Art.-no.

26561
26563
26564
26565
26566
26567

Accuracy class
0.5
0.2
Art.-no. Art.-no.
26770
26771
26786
26777
26772
26778
26773
26774
26779
26775
26776
26780
26789

MBS AG

EASR 22.3
Tube current transformer
Approved current transformer for tariff applications

Secondary current
Primary
current
A
100
150

200

250
300

400

500

600

Burden
VA
1.5
2.5
1.5
2.5
5
1.5
2.5
5
2.5
5
2.5
5
10
2.5
5
10
2.5
5
10
2.5
5
10

5A
Accuracy class
0.5
0.5s
Art.-no. Art.-no.
3530
3552
3531
3553
3532
3554
3533
3555
3534
3556
3535
3557
3536
3558
3537
3559
3538
3560
3539
3561
3540
3562
3541
3563
3542
3564
3543
3565
3544
3566
3545
3567
3546
3568
3547
3569
3548
3570
3549
3571
3550
3572
3551
3573

1A
0.2
Art.-no.
3511
3512
3513
3514
3515
3516
3517
3518
3519
3520
3521
3522
3523
3524
3525
3526
3527
3528
3529

Accuracy class
0.5
0.2
Art.-no. Art.-no.
3730
3711
3731
3732
3712
3733
3713
3734
3735
3714
3736
3715
3737
3716
3738
3717
3739
3718
3740
3719
3741
3720
3743
3744
3745
3746
3747
3748
3749
3750
3751

3721
3722
3723
3724
3725
3726
3727
3728
3729

Snap-on mounting
Primary conductor
Round conductor
Transformer width
Snap-on mounting
Sealed shutter
Current transformer for
industrial applications
Protection plug-in
current transformers

22.5 mm
61 mm
Art.-no. 53011
see page 204
Art.-no. 59040
see page 205
see page 35
see page 125

www.mbs-stromwandler.de

167

MBS AG

EASK 21.3
Plug-in current transformer
Approved current transformer for tariff applications

5A

Secondary current
Primary
current
A
100
150

200

250
300

400

500

Burden
VA
1.5
2.5
1.5
2.5
5
1.5
2.5
5
2.5
5
2.5
5
10
2.5
5
10
2.5
5
10

Accuracy class
0.5
0.5s
Art.-no. Art.-no.
6530
6549
6531
6550
6532
6551
6533
6552
6534
6553
6535
6554
6536
6555
6537
6556
6538
6557
6539
6558
6540
6559
6541
6560
6542
6561
6543
6562
6544
6563
6545
6564
6546
6565
6547
6566
6548
6567

Snap-on mounting

Primary conductor
Round conductor
Transformer width
Snap-on mounting

20 x 10 mm
19.2 mm
61 mm
Art.-no. 53011
see page 204
Art.-no. 59040
see page 205

Sealed shutter
Current transformer
for industrial applications
Protection plug-in
current transformers

168

see page 43
see page 126

www.mbs-stromwandler.de

1A
0.2
Art.-no.
6511
6513
6514

Accuracy class
0.5
0.2
Art.-no. Art.-no.
6730
6711
6731
6732
6713
6733
6714
6734

6516
6517
6518
6519
6520
6521
6522

6736
6737
6738
6739
6740
6741

6717
6718
6719
6720
6721
6722

6524
6525
6526
6527
6528
6529

6743
6744
6745
6746
6747
6748

6724
6725
6726
6727
6728
6729

MBS AG

EASK 31.3
Plug-in current transformer
Approved current transformer for tariff applications

5A

Secondary current
Primary
current
A
100
150
200
250
300
400
500
600
750

Burden
VA
1.5
2.5
1.5
2.5
2.5
5
2.5
5
2.5
5
2.5
5
2.5
5
2.5
5
2.5
5

Accuracy class
0.5
0.5s
Art.-no. Art.-no.
7533
7555
7534
7556
7535
7557
7536
7558
7537
7559
7538
7560
7539
7561
7540
7562
7541
7563
7542
7564
7543
7565
7544
7566
7546
7568
7547
7569
7549
7571
7550
7572
7552
7574
7553
7575

1A
0.2
Art.-no.
7511
7513
7515
7516
7517
7518
7519
7520
7521
7522
7524
7525
7527
7528
7530
7531

Snap-on mounting
Primary conductor
Round conductor
Transformer width
Snap-on mounting
Sealed shutter
Current transformer
for industrial applications

30 x 10 mm
2 x 20 x 10 mm
26 mm
61 mm
Art.-no. 53011
see page 204
Art.-no. 59040
see page 205
see page 45
www.mbs-stromwandler.de

169

Accuracy c
0.5
Art.-no. Ar

MBS AG

EASK 31.4
Plug-in current transformer
Approved current transformer for tariff applications

Secondary current
Primary
current
A
100
150
200
250
300

400

500

600

750

Primary conductor

30 x 10 mm
2 x 20 x 10 mm
28 mm
61 mm
Art.-no. 54011
see page 204
Art.-no. 59041
see page 205

Round conductor
Transformer width
Snap-on mounting
Sealed shutter
Current transformer
for industrial applications

170

see page 47

www.mbs-stromwandler.de

Burden
VA
1.5
2.5
2.5
5
2.5
5
2.5
5
2.5
5
10
2.5
5
10
2.5
5
10
2.5
5
10
15
2.5
5
10
15

5A

1A

Accuracy class
0.5
0.5s
0.2
Art.-no. Art.-no.
Art.-no.
8510
8535
8559
8511
8536
8560
8512
8537
8561
8538
8562
8514
8539
8563
8515
8540
8564
8516
8541
8565
8517
8542
8566
8518
8543
8567
8519
8544
8568
8520
8545
8569
8521
8546
8570
8522
8547
8571
8523
8548
8572
8524
8549
8573
8525
8550
8574
8526
8551
8575
8527
8552
8576
8528
8553
8577
8529
8554
8578
8555
8579
8531
8556
8580
8532
8557
8581
8533
8558
8582

Accuracy class
0.5
0.2
Art.-no. Art.-no.

Snap-on mounting

8735
8736
8737
8738
8739
8740
8741
8742
8743
8744
8745
8746
8747
8748
8749
8750
8751
8752
8753
8754
8755
8756
8757
8758

8711
8712
8714
8715
8716
8717
8718
8719
8720
8721
8722
8723
8724
8725
8726
8727
8728
8729
8731
8732
8733

MBS AG

EASK 31.5
Plug-in current transformer
Approved current transformer for tariff applications

5A

Secondary current
Primary
current
A
75
100
150
200

250

300

400

500

600

750

Burden
VA
2.5
2.5
5
2.5
5
2.5
5
10
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15

1A

Accuracy class
0.5
0.5s
0.2
Art.-no. Art.-no. Art.-no.
9542
9574
9543
9575
9511
9544
9576
9545
9577
9513
9546
9578
9514
9547
9579
9515
9548
9580
9516
9549
9581
9550
9582
9518
9551
9583
9519
9552
9584
9520
9553
9585
9554
9586
9522
9555
9587
9523
9556
9588
9524
9557
9589
9558
9590
9526
9559
9591
9527
9560
9592
9528
9561
9593
9562
9594
9530
9563
9595
9531
9564
9596
9532
9565
9597
9566
9598
9534
9567
9599
9535
9568
9600
9536
9569
9601
9570
9602
9538
9571
9603
9539
9572
9604
9540
9573
9605

0.2s
Art.-no.

V17-1604D
V17-1704D
V17-1704F
V17-1804D
V17-1804F

V17-1904D
V17-1904F

V17-2004D
V17-2004F
V17-2004H
V17-2104D
V17-2104F
V17-2104H
V17-2204D
V17-2204F
V17-2204H
V17-2304D
V17-2304F
V17-2304H

Accuracy class
0.5
0.2
Art.-no. Art.-no.
9742
9743
9711
9744
9745
9713
9746
9714
9747
9715
9748
9716
9749
9750
9718
9751
9719
9752
9720
9753
9754
9722
9755
9723
9756
9724
9757
9758
9726
9759
9727
9760
9728
9761
9762
9730
9763
9731
9764
9732
9765
9766
9734
9767
9735
9768
9736
9769
9770
9738
9771
9739
9772
9740
9773

EASK 31.5 2U
5A

Secondary current
Primary conductor
Round conductor
Transformer width
Snap-on mounting
Sealed shutter
Current transformer
for industrial applications
Protection plug-in
current transformers

30 x 10 mm
2 x 20 x 10 mm
28 mm
61 mm
Art.-no. 55011
see page 204
Art.-no. 59041
see page 205

Primary
current
A
200-100
300-150
400-200
500-250

see page 49
600-300
see page 127

Accuracy class
Burden
VA
5-2.5
10-5
5-2.5
10-5
5-2.5
10-5
5-2.5
10-5
5-2.5
10-5

0.5
Art.-no.
9606
9607
9608
9609
9610
9611
9612
9613
9614
9615

www.mbs-stromwandler.de

0.5s
Art.-no.
9616
9618
9619
9620
9621
9622
9623
9624
9625

171

MBS AG

EASK 31.6
Plug-in current transformer
Approved current transformer for tariff applications

Secondary current
Primary
current
A
50
75
100

150

200

250

300

400

500

600

750

Primary conductor

30 x 10 mm
20 x 13 mm
23 mm
95 mm

Art.-no. 59044
see page 205

Round conductor
Transformer width
Snap-on mounting
Sealed shutter
Current transformer
for industrial applications
Protection plug-in
current transformers

172

see page 51
see page 128

www.mbs-stromwandler.de

Burden
VA
2.5
2.5
5
2.5
5
10
2.5
5
10
15
5
10
15
5
10
15
5
10
15
30
5
10
15
30
5
10
15
30
5
10
15
30
5
10
15
30

5A
Accuracy class
0.5
0.5s
Art.-no. Art.-no.
10547
10585
10548
10586
10549
10587
10550
10588
10551
10589
10552
10590
10553
10591
10554
10592
10555
10593
10556
10594
10557
10595
10558
10596
10559
10597
10560
10598
10561
10599
10563
10600
10565
10602
10566
10603
10567
10604
10568
10605
10569
10606
10570
10607
10571
10608
10572
10609
10573
10610
10574
10611
10575
10612
10576
10613
10577
10614
10578
10615
10579
10616
10580
10617
10581
10618
10582
10619
10583
10620
10584
10621

1A
0.2
Art.-no.

10513
10514
10516
10517

10521
10522
10524
10525
10528
10529

10532
10533
10534
10536
10537
10538
10540
10541
10542
10543
10544
10545

Accuracy class
0.5
0.2
Art.-no. Art.-no.
10747
10748
10749
10750
10713
10751
10714
10752
10753
10716
10754
10717
10755
10756
10757
10721
10758
10722
10759
10760
10724
10761
10725
10763
10765
10728
10766
10729
10767
10768
10769
10732
10770
10733
10771
10734
10772
10773
10736
10774
10737
10775
10738
10776
10777
10740
10778
10741
10779
10742
10780
10781
10743
10782
10744
10783
10745
10784

MBS AG

Low voltage current transformers


for tariff applications
EASK 41.4
EASK 41.4 2U

Primary conductor

EASK 41.5

Primary conductor

40 x 10
2 x 30 x 5
32
71

mm
mm
mm
mm

40 x 10
2 x 30 x 5
32
71

mm
mm
mm
mm

40 x 12
30 x 15
32
95

mm
mm
mm
mm

40 x 10
2 x 30 x 5
32
86

mm
mm
mm
mm

50 x 12
2 x 40 x 10
44
86

mm
mm
mm
mm

50 x 12
40 x 30
40
95

mm
mm
mm
mm

Round conductor
Transformer width

Round conductor
Transformer width

EASK 41.6

Primary conductor
Round conductor
Transformer width

EASK 541.4

Primary conductor
Round conductor
Transformer width

EASK 41.6
EASK 41.6 2U

Primary conductor

EASK 51.6

Primary conductor

Round conductor
Transformer width

Round conductor
Transformer width

Type E denotes that the current transformers are suitable for calibration

www.mbs-stromwandler.de

173

MBS AG

EASK 41.4
Plug-in current transformer
Approved current transformer for tariff applications

5A

Secondary current
Primary
current
A
100
150

200

250

300

400

500

600

750

Burden
VA
1.5
2.5
1.5
2.5
5
1.5
2.5
5
1.5
2.5
5
2.5
5
10
2.5
5
10
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15

1A

Accuracy class
0.5
0.5s
Art.-no. Art.-no.
13540
13569
13541
13570
13542
13571
13543
13572
13544
13573
13545
13574
13546
13575
13548
13576
13549
13550
13551
13552
13553
13554
13555
13556
13557
13558
13559
13560
13561
13562
13563
13564
13565
13566
13567
13568

13578
13579
13580
13581
13582
13583
13584
13585
13586
13587
13588
13589
13590
13591
13592
13593
13594
13595
13596
13597

0.2
Art.-no.
13511
13513
13514
13516
13517
13518
13520
13521
13522
13523
13525
13526
13527
13528
13529
13530
13531
13532
13533
13534
13535
13536
13537
13538
13539

Accuracy class
0.5
0.2
Art.-no. Art.-no.
13740
13711
13741
13742
13713
13743
13714
13744
13745
13716
13746
13717
13747
13718
13719
13749
13720
13750
13721
13751
13722
13752
13723
13753
13754
13725
13755
13726
13756
13727
13757
13728
13758
13729
13759
13730
13760
13731
13761
13732
13762
13733
13763
13734
13764
13735
13765
13736
13766
13737
13767
13738
13768

EASK 41.4 2U
5A

Secondary current
Primary conductor

40 x 10 mm
2 x 30 x 5 mm
32 mm
71 mm
Art.-no. 55012
see page 204
Art.-no. 59041
see page 205

Round conductor
Transformer width
Snap-on mounting
Sealed shutter
Current transformer
for industrial applications
Protection plug-in
current transformers

174

Primary
current
A
200-100
300-150
400-200
500-250

see page 56
600-300
see page 133

www.mbs-stromwandler.de

Accuracy class
Burden
VA
5-2.5
5-2.5
10-5
5-2.5
10-5
5-2.5
10-5
5-2.5
10-5

0.5
Art.-no.
13598
13599
13600
13601
13602
13603
13604
13605
13606

0.5s
Art.-no.
13607
13608
13609
13610
13611
13612
13613
13614
13615

MBS AG

EASK 41.6
Plug-in current transformer
Approved current transformer for tariff applications

Secondary current
Primary
current
A
75
100

150

200

250

300

400

500

600

750

1000
Primary conductor

40 x 12 mm
30 x 15 mm
32 mm
95 mm

Art.-no. 59044
see page 205

Round conductor
Transformer width
Snap-on mounting
Sealed shutter
Current transformer
for industrial applications
Protection plug-in
current transformers

176

see page 61
see page 134

www.mbs-stromwandler.de

Burden
VA
2.5
5
2.5
5
10
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
30
2.5
5
10
15
30
5
10
15
30

5A
Accuracy class
0.5
0.5s
Art.-no. Art.-no.
14552
14595
14553
14596
14554
14597
14555
14598
14556
14599
14557
14600
14558
14601
14559
14602
14560
14603
14561
14604
14562
14605
14563
14606
14564
14607
14565
14608
14566
14609
14567
14610
14568
14611
14569
14612
14570
14613
14571
14614
14572
14615
14573
14616
14574
14617
14575
14618
14576
14619
14577
14620
14578
14621
14579
14622
14580
14623
14581
14624
14582
14625
14583
14626
14584
14627
14585
14628
14586
14629
14587
14630
14588
14631
14589
14632
14590
14633
14591
14634
14592
14635
14593
14636
14594
14637

1A

14528
14529
14530
14531
14532
14533
14534
14535
14536
14537
14538
14539
14540
14541
14542
14543

Accuracy class
0.5
0.2
Art.-no. Art.-no.
14752
14753
14754
14713
14755
14756
14757
14716
14758
14717
14759
14760
14761
14720
14762
14721
14763
14722
14764
14765
14724
14766
14725
14767
14726
14768
14769
14728
14770
14729
14771
14730
14772
14731
14773
14732
14774
14733
14775
14734
14776
14735
14777
14736
14778
14737
14779
14738
14780
14739
14781
14740
14782
14741
14783
14742
14784
14743

14544
14545
14546
14547

14786
14787
14788
14789

14744
14745
14746
14747

14548
14549
14550

14791
14792
14793

14748
14749
14750

0.2
Art.-no.

14513

14516
14517

14520
14521
14522
14524
14525
14526

MBS AG

EASK 541.4
Plug-in current transformer
Approved current transformer for tariff applications

Secondary current
Primary
current
A
75
100

150

200

250

300

400

500

600

750

Primary conductor
Round conductor
Transformer width
Snap-on mounting
Sealed shutter
Current transformer
for industrial applications
Protection plug-in
current transformers

40 x 10 mm
2 x 30 x 5 mm
32 mm
86 mm

Art.-no. 59042
see page 205

1000

Burden
VA
1.5
2.5
1.5
2.5
5
1.5
2.5
5
10
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
30
2.5
5
10
15
30
2.5
5
10
15
30
2.5
5
10
15
30
2.5
5
10
15
30

5A
Accuracy class
0.5
0.5s
Art.-no. Art.-no.
15557
15603
15558
15604
15559
15605
15560
15606
15561
15607
15562
15608
15563
15609
15564
15610
15565
15611
15566
15612
15567
15613
15568
15614
15569
15615
15570
15616
15571
15617
15572
15618
15573
15619
15574
15620
15575
15621
15576
15622
15577
15623
15578
15624
15579
15625
15580
15626
15581
15627
15582
15628
15583
15629
15584
15630
15585
15631
15586
15632
15587
15633
15588
15634
15589
15635
15590
15636
15591
15637
15592
15638
15593
15639
15594
15640
15595
15641
15596
15642
15597
15643
15598
15644
15599
15645
15600
15646
15601
15647
15602
15648

1A

15528
15529
15530
15531
15532
15533
15534
15535

Accuracy class
0.5
0.2
Art.-no. Art.-no.
15757
15758
15759
15713
15760
15714
15761
15762
15716
15763
15717
15764
15718
15765
15766
15720
15767
15721
15768
15722
15769
15770
15724
15771
15725
15772
15726
15773
15727
15774
15728
15775
15729
15776
15730
15777
15731
15778
15732
15779
15733
15780
15734
15781
15735

15537
15538
15539
15540

15783
15784
15785
15786

15737
15738
15739
15740

15542
15543
15544
15545
15546
15547
15548
15549
15550
15551
15552
15553
15554
15555
15556

15788
15789
15790
15791

15742
15743
15744
15745

15793
15794
15795
15796

15747
15748
15749
15750

15799
15800
15801

15753
15754
15755

0.2
Art.-no.

15513
15514
15516
15517
15518
15520
15521
15522
15524
15525
15526

see page 64
see page 140

www.mbs-stromwandler.de

177

MBS AG

EASK 51.4
Plug-in current transformer
Approved current transformer for tariff applications

5A

Secondary current
Primary
current
A
100
150
200

250

300
400

500

600

750

1000

Burden
VA
1.5
2.5
1.5
2.5
1.5
2.5
5
1.5
2.5
5
2.5
5
2.5
5
10
2.5
5
10
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15

1A

Accuracy class
0.5
0.5s
Art.-no. Art.-no.
16542
16573
16543
16574
16544
16575
16545
16576
16546
16577
16547
16578
16548
16579
16549
16580
16550
16581
16551
16582
16553
16584
16554
16585
16555
16586
16556
16587
16557
16588
16558
16589
16559
16590
16560
16591
16561
16592
16562
16593
16563
16594
16564
16595
16565
16596
16566
16597
16567
16598
16568
16599
16569
16600
16570
16601
16571
16602
16572
16603

0.2
Art.-no.

16513
16515
16516
16517
16518
16519
16520
16522
16523
16524
16525
16526
16527
16528
16529
16530
16531
16532
16533
16534
16535
16536
16537
16538
16539
16540
16541

Accuracy class
0.5
0.2
Art.-no. Art.-no.
16742
16743
16744
16713
16745
16746
16715
16747
16716
16748
16717
16749
16718
16750
16719
16751
16720
16753
16722
16754
16723
16755
16724
16756
16725
16757
16726
16758
16727
16759
16728
16760
16729
16761
16730
16762
16731
16763
16732
16764
16733
16734
16766
16735
16767
16736
16768
16737
16770
16771
16772

16739
16740
16741

EASK 51.4 2U
Secondary current

Primary conductor

50 x 12 mm
2 x 40 x 10 mm
44 mm
86 mm

Art.-no. 59042
see page 205

Round conductor
Transformer width
Snap-on mounting
Sealed shutter
Current transformer
for industrial applications
Protection plug-in
current transformers

178

Primary
current
A
200-100
300-150
400-200
500-250
600-300

see page 65
1000-500
see page 142

www.mbs-stromwandler.de

Burden
VA
5-2.5
5-2.5
5-2.5
10-5
5-2.5
10-5
5-2.5
10-5
5-2.5
10-5

5A

1A

Accuracy class
0.5
Art.-no.
16611
16612
16613
16614
16615
16616
16617
16618
16619
16620

Accuracy class
0.5s
Art.-no.
16621
16622
16623
16624
16625
16626
16627
16628
16629
16630

MBS AG

EASK 51.6
Plug-in current transformer
Approved current transformer for tariff applications

Secondary current
Primary
current
A
100
150

200

250

300

400

500

600

750

1000

1200

Primary conductor
Round conductor
Transformer width
Snap-on mounting
Sealed shutter
Current transformer
for industrial applications
Protection plug-in
current transformers

50 x 12 mm
40 x 30 mm
40 mm
95 mm

Art.-no. 59044
see page 205

1250

Burden
VA
2.5
5
2.5
5
10
2.5
5
10
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
5
10
15
30
5
10
15
30
5
10
15
30

5A
Accuracy class
0.5
0.5s
Art.-no. Art.-no.
17555
17599
17556
17600
17557
17601
17558
17602
17559
17603
17560
17604
17561
17605
17562
17606
17563
17607
17564
17608
17565
17609
17566
17610
17567
17611
17568
17612
17569
17613
17570
17614
17571
17615
17572
17616
17573
17617
17574
17618
17575
17619
17576
17620
17577
17621
17578
17622
17579
17623
17580
17624
17581
17625
17582
17626
17583
17627
17584
17628
17585
17629
17586
17630
17587
17631
17588
17632
17589
17633
17590
17634
17591
17635
17592
17636
17593
17637
17594
17638
17595
17639
17596
17640
17597
17641
17598
17642

1A

17535
17536
17537
17538
17539
17540
17541
17542
17543
17544
17545

Accuracy class
0.5
0.2
Art.-no. Art.-no.
17755
17711
17756
17757
17713
17758
17714
17759
17760
17716
17761
17717
17762
17763
17719
17764
17720
17765
17721
17766
17767
17723
17768
17724
17769
17725
17770
17771
17727
17772
17728
17773
17729
17774
17775
17731
17776
17732
17777
17733
17778
17779
17735
17780
17736
17781
17737
17782
17738
17783
17739
17784
17740
17785
17741
17786
17742
17787
17743
17788
17744
17789
17745

17547
17548
17549

17791
17792
17793

17747
17748
17749

17551
17552
17553

17795
17796
17797

17751
17752
17753

0.2
Art.-no.
17511
17513
17514
17516
17517
17519
17520
17521
17523
17524
17525
17527
17528
17529
17531
17532
17533

see page 67
see page 144

www.mbs-stromwandler.de

179

MBS AG

MBS AG

Low voltage current transformers


for tariff applications
60 x 10
2 x 50 x 10
44
96

mm
mm
mm
mm

Round conductor
Transformer width

60 x 10
50 x 30
40
95

mm
mm
mm
mm

EASK 63.6

Primary conductor
Round conductor
Transformer width

60 x 30 mm
30 mm
88 mm

EASK 81.4

Primary conductor

80 x 10 mm
60 x 30 mm
2 x 60 x 10 mm
55 mm
120 mm

EASK 61.4

Primary conductor
Round conductor
Transformer width

EASK 61.6

Primary conductor

Round conductor
Transformer width

Type E denotes that the current transformers are suitable for calibration

www.mbs-stromwandler.de

181

MBS AG

EASK 61.4
Plug-in current transformer
Approved current transformer for tariff applications

Secondary current
Primary
current
A
200
250

300

400

500

600

750

1000

1200

1250

1500
Primary conductor

60 x 10 mm
2 x 50 x 10 mm
44 mm
96 mm

Art.-no. 59042
see page 205

Round conductor
Transformer width
Snap-on mounting
Sealed shutter
Current transformer
for industrial applications
Protection plug-in
current transformers

182

see page 70
see page 148

www.mbs-stromwandler.de

Burden
VA
1.5
2.5
1.5
2.5
5
1.5
2.5
5
10
2.5
5
10
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
30
2.5
5
10
15
30
5
10
15
30
5
10
15
30

5A
Accuracy class
0.5
0.5s
Art.-no. Art.-no.
19555
19599
19556
19600
19557
19601
19558
19602
19559
19603
19560
19604
19561
19605
19562
19606
19563
19607
19564
19608
19565
19609
19566
19610
19567
19611
19568
19612
19569
19613
19570
19614
19571
19615
19572
19616
19573
19617
19574
19618
19575
19619
19576
19620
19577
19621
19578
19622
19580
19624
19581
19625
19582
19626
19583
19627
19584
19628
19585
19629
19586
19630
19587
19631
19588
19632
19589
19590
19634
19591
19635
19592
19636
19593
19637
19595
19639
19596
19640
19597
19641
19598
19642

1A

19527
19528
19529
19530
19531
19532
19533
19534
19536
19537
19538
19539

Accuracy class
0.5
0.2
Art.-no. Art.-no.
19755
19711
19756
19712
19757
19713
19758
19714
19759
19715
19760
19716
19761
19717
19762
19718
19763
19764
19720
19765
19721
19766
19722
19767
19723
19768
19724
19769
19725
19770
19771
19727
19772
19728
19773
19729
19774
19730
19775
19731
19776
19732
19777
19733
19778
19734
19736
19780
19737
19781
19738
19782

19541
19542
19543
19544

19785
19786
19787

19741
19742
19743

19546
19547
19548

19790
19791
19792

19746
19747
19748

19551
19552
19553

19795
19796
19797

19751
19752
19753

0.2
Art.-no.
19511
19512
19513
19514
19515
19516
19517
19518
19520
19521
19522
19523
19524
19525

MBS AG

EASK 61.6
Plug-in current transformer
Approved current transformer for tariff applications

Secondary current
Primary
current
A
200
250

300

400

500

600

750

1000

1200

1250

1500

Primary conductor
Round conductor
Transformer width
Snap-on mounting
Sealed shutter
Current transformer
for industrial applications

Burden
VA
2.5
5
2.5
5
10
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
5
10
15
30
5
10
15
30
5
10
15
30
5
10
15
30

5A
Accuracy class
0.5
0.5s
Art.-no. Art.-no.
20552
20593
20553
20594
20554
20595
20555
20596
20556
20597
20557
20598
20558
20599
20559
20600
20560
20601
20561
20602
20562
20603
20563
20604
20564
20605
20565
20606
20566
20607
20567
20608
20568
20609
20569
20610
20570
20611
20571
20612
20572
20613
20573
20614
20574
20615
20575
20616
20576
20617
20577
20618
20578
20619
20579
20620
20580
20621
20581
20622
20582
20623
20583
20624
20584
20625
20585
20626
20586
20627
20587
20628
20588
20629
20589
20630
20590
20631
20591
20632
20592
20633

1A

20532
20533
20534
20535
20536
20537
20538

Accuracy class
0.5
0.2
Art.-no. Art.-no.
20752
20711
20753
20754
20713
20755
20714
20756
20757
20716
20758
20717
20759
20718
20760
20761
20720
20762
20721
20763
20722
20764
20765
20724
20766
20725
20767
20726
20768
20769
20728
20770
20729
20771
20730
20772
20773
20732
20774
20733
20775
20734
20776
20735
20777
20736
20778
20737
20779
20738

20540
20541
20542

20781
20782
20783

20740
20741
20742

20544
20545
20546

20785
20786
20787

20744
20745
20746

20548
20549
20550

20789
20790
20791

20748
20749
20750

0.2
Art.-no.
20511
20513
20514
20516
20517
20518
20520
20521
20522
20524
20525
20526
20528
20529
20530

60 x 10 mm
50 x 30 mm
40 mm
95 mm

Art.-no. 59044
see page 205
see page 72
www.mbs-stromwandler.de

183

MBS AG

EASK 63.6
Plug-in current transformer
Approved current transformer for tariff applications

Secondary current
Primary
current
A
250
300

400

500

600

750

1000

1200

1250

1500

Primary conductor
Round conductor
Transformer width
Snap-on mounting
Sealed shutter

60 x 30 mm
30 mm
88 mm

Art.-no. 59042
see page 205

Current transformer
for industrial applications
Protection plug-in
current transformers

184

see page 74
see page 152

www.mbs-stromwandler.de

Burden
VA
2.5
5
2.5
5
10
2.5
5
10
2.5
5
10
15
2.5
5
10
15
5
10
15
30
5
10
15
30
5
10
15
30
5
10
15
30
5
10
15
30

5A
Accuracy class
0.5
0.5s
Art.-no. Art.-no.
85558
85602
85559
85603
85560
85604
85561
85605
85562
85606
85563
85607
85564
85608
85565
85609
85566
85610
85567
85611
85568
85612
85569
85613
85570
85614
85571
85615
85572
85616
85573
85617
85574
85618
85575
85619
85576
85620
85577
85621
85578
85622
85579
85623
85580
85624
85581
85625
85582
85626
85583
85627
85584
85628
85585
85629
85586
85630
85587
85631
85588
85632
85589
85633
85590
85634
85591
85635
85592
85636
85593
85637

1A
0.2
Art.-no.
85513
85515
85516
85518
85519
85520
85521
85522
85523
85525
85526
85527
85528
85530
85531
85532
85534
85535
85536
85538
85539
85540
85542
85543
85544
85546
85547
85548

Accuracy class
0.5
0.2
Art.-no. Art.-no.
85758
85713
85759
85760
85715
85761
85716
85762
85763
85718
85764
85719
85765
85720
85766
85721
85767
85722
85768
85723
85769
85770
85725
85771
85726
85772
85727
85773
85728
85774
85730
85775
85731
85776
85732
85777
85778
85734
85779
85735
85780
85736
85781
85782
85738
85783
85739
85784
85740
85785
85786
85742
85787
85743
85788
85744
85789
85790
85746
85791
85747
85792
85748
85793

MBS AG

EASK 81.4
Plug-in current transformer
Approved current transformer for tariff applications

Secondary current
Primary
current
A
400

500

600

750

1000

1200

1250

1500

Primary conductor

Round conductor
Transformer width
Snap-on mounting
Sealed shutter
Current transformer
for industrial applications

Burden
VA
2.5
5
10
2.5
5
10
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
5
10
15
5
10
15
2.5
5
10
15

5A
Accuracy class
0.5
0.5s
Art.-no. Art.-no.
21541
21571
21542
21572
21543
21573
21544
21574
21545
21575
21546
21576
21547
21577
21548
21578
21549
21579
21550
21580
21551
21581
21552
21582
21553
21583
21554
21584
21555
21585
21556
21586
21557
21587
21558
21588
21560
21590
21561
21591
21562
21592
21564
21594
21565
21595
21566
21596
21567
21597
21568
21598
21569
21599
21570
21600

1A
0.2
Art.-no.
21511
21512
21514
21515
21516
21517
21518
21519
21520
21521
21522
21523
21524
21525
21526
21527
21528
21530
21531
21532
21534
21535
21536
21537
21538
21539
21540

Accuracy class
0.5
0.2
Art.-no. Art.-no.
21741
21711
21742
21712
21743
21744
21714
21745
21715
21746
21716
21747
21717
21748
21718
21749
21719
21751
21752
21753

21721
21722
21723

21756
21757
21758
21760
21761
21762
21764
21765
21766

21726
21727

21768
21769
21770

21738
21739
21740

21730
21731
21734
21735
21736

80 x 10 mm
60 x 30 mm
2 x 60 x 10 mm
55 mm
120 mm

Art.-no. 59042
see page 205
see page 75
www.mbs-stromwandler.de

185

MBS AG

MBS AG

Low voltage current transformers


for tariff applications
EASK 105.6

Primary conductor
Round conductor
Transformer width

EASK 123.3

Primary conductor
Round conductor
Transformer width

100 x 55 mm
55 mm
129 mm

123 x 30
3 x 100 x 10
100
172

mm
mm
mm
mm

EASK 130.3

Primary conductor
Transformer width

130 x 25 mm
180 mm

EASK 130.5

Primary conductor
Transformer width

130 x 30 mm
180 mm

Type E denotes that the current transformers are suitable for calibration

www.mbs-stromwandler.de

187

MBS AG

EASK 105.6
Plug-in current transformer
Approved current transformer for tariff applications

Secondary current
Primary
current
A
600
750

1000

1200

1250

1500

1600

2000

2500

3000

Primary conductor
Round conductor
Transformer width
Snap-on mounting
Sealed shutter

100 x 55 mm
55 mm
129 mm

Art.-no. 59042
see page 205

Current transformer
for industrial applications
Protection plug-in
current transformers

188

see page 86
see page 153

www.mbs-stromwandler.de

Burden
VA
2.5
5
2.5
5
10
2.5
5
10
15
5
10
15
5
10
15
30
5
10
15
30
5
10
15
30
5
10
15
30
5
10
15
30
5
10
15
30

5A
Accuracy class
0.5
0.5s
Art.-no. Art.-no.
86568
86622
86569
86623
86571
86625
86572
86626
86573
86627
86574
86575
86629
86576
86630
86577
86631
86579
86633
86580
86634
86581
86635
86583
86637
86584
86638
86585
86639
86586
86640
86588
86642
86589
86643
86590
86644
86591
86645
86593
86647
86594
86648
86595
86649
86596
86650
86598
86652
86599
86653
86600
86654
86601
86655
86603
86657
86604
86658
86605
86659
86606
86660
86662
86609
86663
86610
86664
86611
86665

1A
0.2
Art.-no.
86515
86516
86518
86519
86520
86522
86523
86524
86526
86527
86528
86530
86531
86532
86535
86536
86537
86538
86540
86541
86542
86543
86545
86546
86547
86548
86550
86551
86552
86553
86555
86556
86557
86558

Accuracy class
0.5
0.2
Art.-no. Art.-no.
86768
86715
86769
86716
86771
86718
86772
86719
86773
86720
86775
86776
86777
86779
86780
86781
86783
86784
86785
86786
86788
86789
86790
86791

86722
86723
86724
86726
86727
86728
86730
86731
86732

86794
86795
86796

86741
86742
86743

86799
86800
86801

86746
86747
86748

86804
86805
86806

86751
86752
86753

86809
86810
86811

86756
86757
86758

86735
86736
86737
86738

MBS AG

EASK 123.3
Plug-in current transformer
Approved current transformer for tariff applications

Secondary current
Primary
current
A
750

1000

1200

1250

1500

1600

2000

2500

3000

Primary conductor
Round conductor
Transformer width
Snap-on mounting
Sealed shutter
Current transformer
for industrial applications

Burden
VA
2.5
5
10
2.5
5
10
5
10
15
5
10
15
5
10
15
30
5
10
15
30
5
10
15
30
5
10
15
30
5
10
15
30

5A
Accuracy class
0.5
0.5s
0.2
Art.-no.
Art.-no.
Art.-no.
V56-2301D V56-2302D
V56-2301F V56-2302F
V56-2301H V56-2302H
V56-2501D V56-2502D V56-2503D
V56-2501F V56-2502F V56-2503F
V56-2501H V56-2502H
V56-2601F V56-2602F V56-2603F
V56-2601H V56-2602H V56-2603H
V56-2601J V56-2602J
V56-2701F V56-2702F V56-2703F
V56-2701H V56-2702H V56-2703H
V56-2701J V56-2702J V56-2703J
V56-2801F V56-2802F V56-2803F
V56-2801H V56-2802H V56-2803H
V56-2801J V56-2802J V56-2803J
V56-2801L V56-2802L
V56-2901F V56-2902F V56-2903F
V56-2901H V56-2902H V56-2903H
V56-2901J V56-2902J V56-2903J
V56-2901L V56-2902L
V56-3001F V56-3002F V56-3003F
V56-3001H V56-3002H V56-3003H
V56-3001J V56-3002J V56-3003J
V56-3001L V56-3002L
V56-3201F V56-3202F V56-3203F
V56-3201H V56-3202H V56-3203H
V56-3201J V56-3202J V56-3203J
V56-3201L V56-3202L
V56-3301F V56-3302F V56-3303F
V56-3301H V56-3302H V56-3303H
V56-3301J V56-3302J V56-3303J
V56-3301L V56-3302L

120 x 30 mm
3 x 100 x 10 mm
100 mm
172 mm

Art.-no. 59040
see page 205
see page 88

www.mbs-stromwandler.de

189

MBS AG

EASK 130.3
Plug-in current transformer
Approved current transformer for tariff applications

Secondary current
Primary
current
A
300
400

500

600

750

1000

1200

1250

1500

1600

Primary conductor
130 x 25 mm
Round conductor

Transformer width
180 mm
Snap-on mounting

Sealed shutter

Current transformer
for industrial applications see page 94

190

www.mbs-stromwandler.de

Burden
VA
2.5
5
2.5
5
10
2.5
5
10
2.5
5
10
2.5
5
10
15
5
10
15
5
10
15
5
10
15
5
10
15
30
5
10
15
30

5A

1A

Accuracy class
0.5
0.5s
0.2
Art.-no.
Art.-no.
Art.-no.
V50-1901D V50-1902D
V50-1901F
V50-2001D V50-2002D V50-2003D
V50-2001F V50-2002F
V50-2001H
V50-2101D V50-2102D V50-2103D
V50-2101F V50-2102F
V50-2101H
V50-2201D V50-2202D V50-2203D
V50-2201F V50-2202F V50-2203F
V50-2201H
V50-2301D V50-2302D V50-2303D
V50-2301F V50-2302F V50-2303F
V50-2301H V50-2302H
V50-2301J
V50-2501F V50-2502F V50-2503F
V50-2501H V50-2502H V50-2503H
V50-2501J V50-2502J
V50-2601F V50-2602F V50-2603F
V50-2601H V50-2602H V50-2603H
V50-2601J V50-2602J V50-2603J
V50-2701F V50-2702F V50-2703F
V50-2701H V50-2702H V50-2703H
V50-2701J V50-2702J V50-2703J
V50-2801F V50-2802F V50-2803F
V50-2801H V50-2802H V50-2803H
V50-2801J V50-2802J V50-2803J
V50-2801L
V50-2901F V50-2902F V50-2903F
V50-2901H V50-2902H V50-2903H
V50-2901J V50-2902J V50-2903J
V50-2901L V50-2902L

Accuracy class
0.5
0.2
Art.-no.
Art.-no.
V50-1911D
V50-1911F
V50-2011D V50-2013D
V50-2011F
V50-2011H
V50-2111D V50-2113D
V50-2111F
V50-2111H
V50-2211D V50-2213D
V50-2211F V50-2213F
V50-2211H
V50-2311D V50-2313D
V50-2311F V50-2313F
V50-2311H
V50-2311J
V50-2511F V50-2513F
V50-2511H V50-2513H
V50-2511J
V50-2611F V50-2613F
V50-2611H V50-2613H
V50-2611J V50-2613J
V50-2711F V50-2713F
V50-2711H V50-2713H
V50-2711J V50-2713J
V50-2811F V50-2813F
V50-2811H V50-2813H
V50-2811J V50-2813J
V50-2811L
V50-2911F V50-2913F
V50-2911H V50-2913H
V50-2911J V50-2913J
V50-2911L

MBS AG

EASK 130.5
Plug-in current transformer
Approved current transformer for tariff applications

Secondary current
Primary
current
A
300

400

500

600

750

1000

1200

1250

1500

1600

2000

2400

Primary conductor
130 x 30 mm
Round conductor

Transformer width
180 mm
Snap-on mounting

Sealed shutter

Current transformer
for industrial applications see page 95

2500

3000

Burden
VA
2.5
5
10
2.5
5
10
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
5
10
15
30
5
10
15
30
5
10
15
30
5
10
15
30
5
10
15
30
10
15
30
10
15
30
10
15
30
10
15
30

5A

1A

Accuracy class
0.5
0.5s
0.2
Art.-no.
Art.-no.
Art.-no.
V51-1901D V51-1902D
V51-1901F V51-1902F
V51-1901H
V51-2001D V51-2002D V51-2003D
V51-2001F V51-2002F
V51-2001H V51-2002H
V51-2101D V51-2102D V51-2103D
V51-2101F V51-2102F V51-2103F
V51-2101H V51-2102H
V51-2101J
V51-2201D V51-2202D V51-2203D
V51-2201F V51-2202F V51-2203F
V51-2201H V51-2202H
V51-2201J
V51-2301D V51-2302D V51-2303D
V51-2301F V51-2302F V51-2303F
V51-2301H V51-2302H V51-2303H
V51-2301J V51-2302J
V51-2501F V51-2502F V51-2503F
V51-2501H V51-2502H V51-2503H
V51-2501J V51-2502J V51-2503J
V51-2501L V51-2502L
V51-2601F V51-2602F V51-2603F
V51-2601H V51-2602H V51-2603H
V51-2601J V51-2602J V51-2603J
V51-2601L V51-2602L
V51-2701F V51-2702F V51-2703F
V51-2701H V51-2702H V51-2703H
V51-2701J V51-2702J V51-2703J
V51-2701L V51-2702L
V51-2801F V51-2802F V51-2803F
V51-2801H V51-2802H V51-2803H
V51-2801J V51-2802J V51-2803J
V51-2801L V51-2802L
V51-2901F V51-2902F V51-2903F
V51-2901H V51-2902H V51-2903H
V51-2901J V51-2902J V51-2903J
V51-2901L V51-2902L
V51-3001H V51-3002H V51-3003H
V51-3001J V51-3002J V51-3003J
V51-3001L V51-3002L V51-3003L
V51-3101H V51-3102H V51-3103H
V51-3101J V51-3102J V51-3103J
V51-3101L V51-3102L V51-3103L
V51-3201H V51-3202H V51-3203H
V51-3201J V51-3202J V51-3203J
V51-3201L V51-3202L V51-3203L
V51-3301H V51-3302H V51-3303H
V51-3301J V51-3302J V51-3303J
V51-3301L V51-3302L V51-3303L

Accuracy class
0.5
0.2
Art.-no.
Art.-no.
V51-1911D
V51-1911F
V51-1911H
V51-2011D V51-2013D
V51-2011F
V51-2011H
V51-2111D V51-2113F
V51-2111F
V51-2111H
V51-2111J
V51-2211D V51-2213D
V51-2211F V51-2213F
V51-2211H
V51-2211J
V51-2311D V51-2313D
V51-2311F V51-2313F
V51-2311H V51-2313H
V51-2311J
V51-2511F V51-2513F
V51-2511H V51-2513H
V51-2511J V51-2513J
V51-2511L
V51-2611F V51-2613F
V51-2611H V51-2613H
V51-2611J V51-2613J
V51-2611L
V51-2711F V51-2713F
V51-2711H V51-2713H
V51-2711J V51-2713J
V51-2711L
V51-2811F V51-2813F
V51-2811H V51-2813H
V51-2811J V51-2813J
V51-2811L
V51-2911F V51-2913F
V51-2911H V51-2913H
V51-2911J V51-2913J
V51-2911L
V51-3011H V51-3013H
V51-3011J V51-3013J
V51-3011L V51-3013L
V51-3111H V51-3113H
V51-3111J V51-3113J
V51-3111L V51-3113L
V51-3211H V51-3213H
V51-3211J V51-3213J
V51-3211L V51-3213L
V51-3311H V51-3313H
V51-3311J V51-3313J
V51-3311L V51-3313L

www.mbs-stromwandler.de

191

MBS AG

MBS AG

Low voltage current transformers


for tariff applications
Wound current transformers
EWSK

ESUSK

31.5

Transformer width

70 mm

Summation current transformers


Transformer width
28
Transformer depth

156 mm
65 mm

Type E denotes that the current transformers are suitable for calibration

www.mbs-stromwandler.de

193

MBS AG

EWSK 31.5
Wound current transformer
Approved current transformer for tariff applications

Secondary current
Primary
current
A
25

30

40

50

60

75

100

150

Primary conductor
Round conductor
Transformer width
Snap-on mounting
Sealed shutter

70 mm

Art.-no. 59045
see page 205

Current transformer
for industrial applications

194

see page 105

www.mbs-stromwandler.de

Burden
VA
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15

5A
Accuracy class
0.5
0.5s
Art.-no. Art.-no.
33547
33583
33548
33584
33549
33585
33550
33586
33551
33587
33552
33588
33553
33589
33554
33590
33555
33591
33556
33592
33557
33593
33558
33594
33559
33595
33560
33596
33561
33597
33562
33598
33563
33599
33564
33600
33565
33601
33566
33602
33567
33603
33568
33604
33569
33605
33570
33606
33571
33607
33572
33608
33573
33609
33574
33610
33575
33611
33576
33612
33577
33613
33578
33614

1A
0.2
Art.-no.
33511
33512
33513
33515
33516
33517
33519
33520
33521
33523
33524
33525
33527
33528
33529
33531
33532
33533
33535
33536
33537
33539
33540
33541

Accuracy class
0.5
0.2
Art.-no. Art.-no.
33747
33711
33748
33712
33749
33713
33750
33751
33715
33752
33716
33753
33717
33754
33755
33719
33756
33720
33757
33721
33758
33759
33723
33760
33724
33761
33725
33762
33763
33727
33764
33728
33765
33729
33766
33767
33731
33768
33732
33769
33733
33770
33771
33735
33772
33736
33773
33737
33774
33775
33739
33776
33740
33777
33741
33778

MBS AG

ESUSK 28
Summation current transformer
Approved current transformer for tariff applications

Secondary current

5A

Primary
current
A
5+5

5+5+5

5+5+5+5

5+5+5+5+5

5+5+5+5+5+5

5+5+5+5+5+5+5

5+5+5+5+5+5+5+5

Accuracy class
0.2
Art.-no.
40511
40512
40513
40514
40515
40516
40517
40518
40519
40529
40521
40522
40523
40524

Type

Burden
VA
5
10
5
10
5
10
5
10
5
10
5
10
5
10

Connection example for different ratios:


AK-AL
BK-BL
CK-CL
DK-DL
EK-EL
FK-FL
GK-GL

= 1000/5
= 800/5
= 600/5
= 400/5
= 400/5
= 300/5
= 300/5

Connection diagram

Primary conductor
Round conductor
Transformer width
Transformer depth
Snap-on mounting
Sealed shutter
secondary no.
Current transformer
for industrial applications

65 mm
156 mm

Art.-no. 59041 (primary)


Art.-no. 59042 (secondary)
see page 205

For technical information, see page 112 and 113.

see page 115

www.mbs-stromwandler.de

195

MBS AG

MBS AG

Low voltage current transformers


for tariff applications
Three-phase current transformer sets
EASK(D) 21.3

with Plexiglas caps

EASK(D) 31.5
EASK(D) 31.5 2U

with Plexiglas caps

EASKD 31.8
EWSKD 31.8

with Plexiglas caps

www.mbs-stromwandler.de

197

MBS AG

EASK(D) 21.3
Three-phase current transformer set
Approved current transformer for tariff applications

Secondary current
Primary
current
A
3 x 100
3 x 150
3 x 200

Burden
VA
2.5
2.5
5
2.5
5

5A
Accuracy class
0.5
0.5s
Art.-no. Art.-no.
58529
58547
58532
58550
58533
58551
58535
58553
58536
58554

1A
0.2
Art.-no.
58514
58517
58518

Accuracy class
0.5
0.2
Art.-no. Art.-no.
58747
58750
58714
58751
58753
58717
58754
58718

Configuration:
The measuring transformer set consists of 3 individual
current transformers which are mounted on an aluminium
base plate together with the primary conductors L1, L2, L3
and neutral conductor.
The current transformer set can be supplied with or
without fuses. The voltage supply is optional and can be
tapped either from the 10 A-NEOZED fuse or from the
individual primary conductors.
Transparent, sealable covers protect the secondary terminals
of the current transformers against external tampering. All
voltage carrying parts of the assembled current transformer
set are made shock-proof with isolating covers which are
included in the deliveries.
Flexible copper wire with a nominal cross section of 16 mm2
up to 70 mm2 can be connected to the primary connection
terminals.
The configuration of this current transformer set conforms to
the technical requirements and guidance:
DIN EN 60044/1
DIN 42600
VBG 4

198

www.mbs-stromwandler.de

MBS AG

EASK(D) 31.5
Three-phase current transformer set
Approved current transformer for tariff applications

5A

Secondary current
Primary
current
A
3 x 75
3 x 100
3 x 150
3 x 200

3 x 250

3 x 300

3 x 400

3 x 500

3 x 600

3 x 750

Technical description see page 160.

Burden
VA
2.5
2.5
5
2.5
5
2.5
5
10
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15

1A

Accuracy class
0.5
0.5s
Art.-no. Art.-no.
57543
57575
57544
57576
57545
57546
57578
57547
57579
57548
57580
57549
57581
57550
57582
57551
57583
57552
57584
57553
57585
57554
57806
57555
57586
57556
57587
57557
57588
57558
57805
57559
57589
57560
57590
57561
57591
57562
57592
57563
57593
57564
57594
57565
57595
57566
57596
57567
57597
57568
57598
57569
57599
57570
57600
57571
57601
57572
57602
57573
57603
57574
57604

Accuracy class
0.5
0.2
Art.-no. Art.-no.
57743
57744
57712
57745
57746
57714
57747
57715
57748
57716
57749
57717
57750
57751
57719
57752
57720
57753
57721
57754
57755
57723
57756
57724
57757
57725
57758
57759
57727
57760
57728
57761
57729
57762
57763
57731
57764
57732
57765
57733
57766
57767
57735
57768
57736
57769
57737
57770
57771
57739
57772
57740
57773
57741
57774
57742

0.2
Art.-no.
57512
57514
57515
57516
57517
57519
57520
57521
57523
57524
57525
57527
57528
57529
57531
57532
57533
57535
57536
57537
57539
57540
57541
57542

EASK(D) 31.5 2U
5A

Secondary current
Primary
current
A
3x200-100
3x300-150
3x400-200
3x500-250
3x600-300

Accuracy class
Burden
VA
5-2.5
10-5
5-2.5
10-5
5-2.5
10-5
5-2.5
10-5
5-2.5
10-5

0.5
Art.-no.
57605
57606
57607
57608
57609
57610
57611
57612
57613
57614

www.mbs-stromwandler.de

0.5s
Art.-no.
57615
57617
57618
57619
57620
57621
57622
57623
57624

199

MBS AG

EWSKD 31.8
Three-phase current transformer set
Approved current transformer for tariff applications

with base plate


Secondary current
Primary
current
A
3 x 50

3 x 75

3 x 100

3 x 150

Burden
VA
2.5
5
10
2.5
5
10
2.5
5
10
2.5
5
10

5A
Accuracy class
0.5
0.5s
Art.-no. Art.-no.
44561
44601
44562
44602
44563
44603
44565
44605
44566
44606
44567
44607
44569
44609
44570
44610
44571
44611
44573
44613
44574
44614
44575
44615

1A
0.2
Art.-no.
44511
44512
44515
44516
44519
44520
44523
44524
44525

Accuracy class
0.5
0.2
Art.-no. Art.-no.
44761
44711
44762
44712
44763
44765
44715
44766
44716
44767
44769
44719
44770
44720
44771
44773
44723
44774
44724
44775
44725

without base plate and neutral conductor

Secondary current
Primary
current
A
3 x 50

3 x 75

3 x 100

3 x 150

200

www.mbs-stromwandler.de

Burden
VA
2.5
5
10
2.5
5
10
2.5
5
10
2.5
5
10

5A
Accuracy class
0.5
0.5s
Art.-no. Art.-no.
45561
45601
45562
45602
45563
45603
45565
45605
45566
45606
45567
45607
45569
45609
45570
45610
45571
45611
45573
45613
45574
45614
45575
45615

1A
0.2
Art.-no.
45511
45512
45515
45516
45519
45520
45523
45524
45525

Accuracy class
0.5
0.2
Art.-no. Art.-no.
45761
45711
45762
45712
45763
45765
45715
45766
45716
45767
45769
45719
45770
45720
45771
45773
45723
45774
45724
45775
45725

MBS AG

EASKD 31.8
Three-phase current transformer set
Approved current transformer for tariff applications

with base plate


Secondary current
Primary
current
A
3 x 200

3 x 250

3 x 300

3 x 400

3 x 500

3 x 600

Burden
VA
2.5
5
10
2.5
5
10
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15

5A
Accuracy class
0.5
0.5s
Art.-no. Art.-no.
46577
46617
46578
46618
46579
46619
46581
46621
46582
46622
46583
46623
46585
46625
46586
46626
46587
46627
46588
46628
46589
46629
46590
46630
46591
46631
46592
46632
46593
46633
46594
46634
46595
46635
46596
46636
46597
46637
46598
46638
46599
46639
46600
46640

1A
0.2
Art.-no.
46527
46528
46529
46531
46532
46533
46535
46536
46537
46539
46540
46541
46542
46543
46544
46545
46546
46547
46548
46549
46550

Accuracy class
0.5
0.2
Art.-no. Art.-no.
46777
46727
46778
46728
46779
46729
46781
46731
46782
46732
46783
46733
46785
46735
46786
46736
46787
46737
46788
46789
46739
46790
46740
46791
46741
46792
46742
46793
46743
46794
46744
46795
46745
46796
46746
46797
46747
46798
46748
46799
46749
46800
46750

without base plate and neutral conductor


Secondary current
Primary
current
A
3 x 200

3 x 250

3 x 300

3 x 400

3 x 500

3 x 600

Burden
VA
2.5
5
10
2.5
5
10
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15
2.5
5
10
15

5A
Accuracy class
0.5
0.5s
Art.-no. Art.-no.
47577
47617
47578
47618
47579
47619
47581
47621
47582
47622
47583
47623
47585
47625
47586
47626
47587
47627
47588
47628
47589
47629
47590
47630
47591
47631
47592
47632
47593
47633
47594
47634
47595
47635
47596
47636
47597
47637
47598
47638
47599
47639
47600
47640

1A
0.2
Art.-no.
47527
47528
47529
47531
47532
47533
47535
47536
47537
47539
47540
47541
47542
47543
47544
47545
47546
47547
47548
47549
47550

www.mbs-stromwandler.de

Accuracy class
0.5
0.2
Art.-no. Art.-no.
47777
47727
47778
47728
47779
47729
47781
47731
47782
47732
47783
47733
47785
47735
47786
47736
47787
47737
47788
47789
47739
47790
47740
47791
47741
47792
47742
47793
47743
47794
47744
47795
47745
47796
47746
47797
47747
47798
47748
47799
47749
47800
47750

201

MBS AG

MBS AG

Accessories for low voltage current transformers


Snap-on mountings

Copper tubes

Mounting angle

Mounting kit

Secondary cap

Locking pistons

Sealed shutters

Copper bus bars

www.mbs-stromwandler.de

203

MBS AG

Snap-on mountings

Snap-on mounting for


tube-, plug-in, protection- and tariff transformers
For use with MBS current transformers
Art.-no.
ASR 22.3; ASK 21.3; 31.3; 318.3; WSK 30
53011
ASK 31.4
54011
ASK 31.5; WSK 40 N
55011
ASK 41.4; 412.4; WSK 40
55012
ASR 20.3; 201.3
55013
ASR 21.3; ASK 205.3
55014

Copper tubes
Length
34
36
34
36
34
36
32
34
32
34

Copper tube
Outside
Inner
Max. current
22.5
16.5
600 A
22.5
16.5
600 A
different lengths available upon request
22.5
12.5
600 A
22.5
12.5
600 A
different lengths available upon request
22.5
8.5
600 A
22.5
8.5
600 A
different lengths available upon request
21
12.5
600 A
21
12.5
600 A
different lengths available upon request
21
8.5
600 A
21
8.5
600 A
different lengths available upon request

Art.-no.
52011
52012
52021
52022
52031
52032
52041
52042
52051
52052

Mounting angle for 3-phase


current transformer set
Mounting angle for triple set (2 pcs)
plug-in, protection- and tariff transformers
For use with MBS current transformers
ASK 421.4; 41.4; 412.4; WSK 40; WSK 40 N
ASK 41.5

204

www.mbs-stromwandler.de

Art.-no.
59037
59082

MBS AG

Mounting kit
Mounting kit
Screw M 12 x 40
with voltage taps M5
with voltage taps M5 and locking piston bus bar 30 mm
with voltage taps M5 and locking piston bus bar 40 mm
with voltage taps M5 and locking piston bus bar 50 mm
standard
standard with locking piston bus bar 30 mm
standard with locking piston bus bar 40 mm
standard with locking piston bus bar 50 mm

Art.-no.
59026
59027
59030
59081
59028
59029
59030A
59080

Secondary cap
Secondary cap
Art.-no.
53016

Locking pistons
copper bus bar
copper bus bar
copper bus bar

30 x 6
40 x 6
50 x 6

Dimensions [mm]
30 x 8
40 x 8
50 x 8

30 x 10
40 x 10
50 x 10

Art.-no.
59035
59036
59048

Sealed shutters
Sealed shutter for
tube-, plug-in, protection- and tariff current transformers
For use with MBS current transformers
Art.-no.
ASR 22.3; ASK 21.3; 31.3; 318.3; 41.3; 103.3 (2x); 123.3 (2x)
59040
ASK 31.4; 31.5; 421.4; 41.4; 412.4; WSK 40; 60; WSK 40 N; KSU
59041
ASK 541.4; 51.4; 561.4; 61.4; 63.4; 63.6; 81.4; 101.4
59042
ASK 105.6; 105.6N; 127.4; 127.6; 128.4; 129.10
59042
WSK 70.6
59043
ASK 31.6; 41.6; 51.6; 61.6
59044
WSK 31.5
59045
www.mbs-stromwandler.de

205

MBS AG

Copper bus bars


galvanically nickel-plated

Copper bus bar for current transformers for


industrial applications

Copper bus bar for current transformers for


tariff applications

13

14

15

10

16

11

12

206

www.mbs-stromwandler.de

Material E-CU copper plated


acc. to DIN 46433

MBS AG

Copper bus bars


Art.-no.
020060170B003I
020060170B003IO
030060130B006I
030060130B006E
030060130B006IO
030060140B006I
030060140B006E
030060140B006IO
030080130B006I
030080130B006E
030080130B006IO
030080160B006I
030080160B006E
030080160B006IO
030100130B006I
030100130B006E
030100130B006IO
030100140B006I
030100140B006E
030100140B006IO
030100160B006I
030100160B006E
030100160B006IO
040060140B008I
040060140B008E
040060140B008IO
040060160B008I
040060160B008E
040060160B008IO
040100140B008I
040100140B008E
040100140B008IO
040100160B008I
040100160B008E
040100160B008IO
050100140B010I
050100140B010E
050100140B010IO
050100180B010I
050100180B010E
050100180B010IO
050100220B011I
050100220B011E
050100220B011IO
060100180B012I
060100180B012E
060100180B012IO
060100220B013I
060100220B013E
060100220B013IO
080100240B014I
080100240B014E
080100240B014IO
100100240B015I
100100240B015E
100100240B015IO

Configuration Bores Length Width Thickness Max. current


industry
3
170
20
6
300 A
w/o screws
3
170
20
6
300 A
industry
6
130
30
6
300 A
energy supplier
6
130
30
6
300 A
w/o screws
6
130
30
6
300 A
industry
6
140
30
6
300 A
energy supplier
6
140
30
6
300 A
w/o screws
6
140
30
6
300 A
industry
6
130
30
8
400 A
energy supplier
6
130
30
8
400 A
w/o screws
6
130
30
8
400 A
industry
6
160
30
8
400 A
energy supplier
6
160
30
8
400 A
w/o screws
6
160
30
8
400 A
industry
6
130
30
10
750 A
energy supplier
6
130
30
10
750 A
w/o screws
6
130
30
10
750 A
industry
6
140
30
10
750 A
energy supplier
6
140
30
10
750 A
w/o screws
6
140
30
10
750 A
industry
6
160
30
10
750 A
energy supplier
6
160
30
10
750 A
w/o screws
6
160
30
10
750 A
industry
8
140
40
6
500 A
energy supplier
8
140
40
6
500 A
w/o screws
8
140
40
6
500 A
industry
8
160
40
6
500 A
energy supplier
8
160
40
6
500 A
w/o screws
8
160
40
6
500 A
industry
8
140
40
10
800 A
energy supplier
8
140
40
10
800 A
w/o screws
8
140
40
10
800 A
industry
8
160
40
10
800 A
energy supplier
8
160
40
10
800 A
w/o screws
8
160
40
10
800 A
industry
10
140
50
10
1000 A
energy supplier 10
140
50
10
1000 A
w/o screws
10
140
50
10
1000 A
industry
10
180
50
10
1000 A
energy supplier 10
180
50
10
1000 A
w/o screws
10
180
50
10
1000 A
industry
11
220
50
10
1000 A
energy supplier 11
220
50
10
1000 A
w/o screws
11
220
50
10
1000 A
industry
12
180
60
10
1200 A
energy supplier 12
180
60
10
1200 A
w/o screws
12
180
60
10
1200 A
industry
13
220
60
10
1200 A
energy supplier 13
220
60
10
1200 A
w/o screws
13
220
60
10
1200 A
industry
14
240
80
10
1500 A
energy supplier 14
240
80
10
1500 A
w/o screws
14
240
80
10
1500 A
industry
15
240
100
10
2000 A
energy supplier 15
240
100
10
2000 A
w/o screws
15
240
100
10
2000 A

Primary bus bars delivery content:


energy suppliers = with 1 off each mounting kit, nos. 59026 and 59028
industry = with 2 mounting kits, no. 59028
w/o = without screws
additional lengths and special bores upon request.

www.mbs-stromwandler.de

207

MBS AG

MBS AG

Bus bar isolators / Bus bar supports


DB/P
C0/P
CS/P
CT/P
CPE

Spacing isolators

PI/P

Passing isolators

PSP

Vertical bus bar supports

GB

Mounting material
Threaded bolts

SK

Hexagon spacers in brass

Bus bar supports


Bus bar supports L-profile
Bus bar supports Z-profile

www.mbs-stromwandler.de

209

MBS AG

Spacing isolator type DB/P

art.-no. XXXXX
e.g. 90015

art.-no. XXXXX-1 art.-no. XXXXX-2


e.g. 90015-1
e.g. 90015-2

DB/P
Made of Polyglas-polyester material, reinforced with fibreglass, colour red, self extinguishing. The isolators of type
DB are unbreakable and have excellent electrical and mechanical characteristics and can be used under extreme
working conditions such as high room temperatures, also when in contact with corrosive substances, vibrations, etc.
The hexagon, arranged middle layer with two facing sides, facilitates the connection and locking in place the isolator.
Upon request, the isolators can be supplied as follows:
The isolator can be equipped with a thread which is not standard
The isolator can be supplied with one or two threaded bolts GB
Operating temperature:
-40 C to +130 C
Fire resistance:
class: UL94-VO

* sw = screw wide
For mounting and
assembly material
see page 217.

210

Art.- Packaging- Articleno.


unit
group
90015
100
DB
90018
100
DB
90022
100
DB
90025
100
DB
90026
100
DB
90028
250
DB
90029
250
DB
90030
250
DB
90033
80
DB
90034
80
DB
90035
64
DB
90036
64
DB
90037
64
DB
90038
36
DB
90039
36
DB
90040
36
DB
90438
100
DB
90439
100
DB
90440
100
DB
90041
27
DB
90042
27
DB
90043
27
DB
90044
27
DB
90046
36
DB
90047
36
DB
90048
36
DB
90441
25
DB
90442
25
DB
90443
25
DB
90050
22
DB
90051
22
DB
90052
22
DB
90053
12
DB
90054
12
DB
90055
12
DB
90057
8
DB
90058
8
DB

www.mbs-stromwandler.de

Article
12/P
12/P
16/P
20/P
20/P
25/P
25/P
25/P
30/P
30/P
34/P
34/P
34/P
35/P
35/P
35/P
40/P
40/P
40/P
45/P
45/P
45/P
45/P
50/P
50/P
50/P
60/P
60/P
60/P
65/P
65/P
65/P
75/P
75/P
75/P
750/P
750/P

H
(mm)
12
12
16
20
20
25
25
25
30
30
35
35
35
35
35
35
40
40
40
45
45
45
45
50
50
50
60
60
60
63.5
63.5
63.5
76
76
76
75
75

sw*
(mm)
11
11
14
17
17
19
19
19
30
30
32
32
32
41
41
41
40
40
40
41
41
41
41
36
36
36
55
55
55
41
41
41
50
50
50
65
65

D1
(mm)
10
10
13
15
15
15
15
15
26
26
28
28
28
35
35
35
30
30
30
35
35
35
35
29
29
29
40
40
40
35
35
35
36
36
36
52
52

Operating
voltage
220
220
380
500
500
600
600
600
600
600
1000
1000
1000
1000
1000
1000
1000
1000
1000
1500
1500
1500
1500
2000
2000
2000
2000
2000
2000
3000
3000
3000
5000
5000
5000
5000
5000

M
(thread)
M3
M4
M4
M4
M6
M6
M5
M6
M6
M8
M6
M8
M10
M6
M8
M10
M8
M10
M12
M6
M8
M10
M12
M8
M10
M12
M8
M10
M12
M8
M10
M12
M8
M10
M12
M12
M16

A
Colour
(mm)
3

10

10

10

11

12

10

12

12

12

12

12

12

13

20

21

20

17

19

19

19

19

19

18

23

MBS AG

Spacing isolator type DB/P

resistance voltage tracking


[kV]
discharge voltage
[kV]
max. tensile load
fz [kIM]
max. bending load
fb [kIM]
max. compression load
fd [kIM]
max. starting torque
md [Nm]

DB16P DB 20/P DB 25/P DB 30/P DB 34/P DB 35/P DB45/P DB 50/P DB 65/P DB 75/P DB 750/P
3
4
7
8
10
10
12
12
15
25
25
8
15
20
23
30
30
40
40
40
50
50
1
1.5
3
5
8
11
12
8.5
15
23
28
0.5
0.6
1.8
2.5
4.5
8
8
4.5
7
9
15
5
6
21
44
65
80
80
68
83
100
150
0.4
0.4
3
3
5
9
10
5
6
10
13

The types DB , CO/P, CS/P, CT/P and CPE have been tested for insulating material (discharge voltage,
discharge strength and arking) according to the regulations covering VDE 0303 part 2 blueprint march 1987.
Appraisal of the discharge voltage or arking between two unequal electrodes/diameter (25 mm or 75 mm). The test
was made for the norm climate 23/50, ambient temperature (23 2) C and (50 5) % relative humidity.

www.mbs-stromwandler.de

211

MBS AG

Spacing isolator type CO/P 20 mm dia.

Spacing isolator type CS/P 30 mm dia.

CO/P diameter 20 mm

CS/P diameter 30 mm

Made of Polyglass-Polyester material, reinforced fibre


glass, colour red, self extinguishing. Upon request the
isolators type CO/P, can be supplied with 1 or 2 mounting
materials, type GB, fitted and secured with lock tide.

Made of Polyglass-Polyester material, reinforced


fibre glass, colour red, self extinguishing.

Art.- Packaging- Article


no.
unit
group
90061
200
CO/P
90062
200
CO/P
90063
100
CO/P
90064
150
CO/P
90065
200
CO/P
90066
100
CO/P
90067
200
CO/P
90068
150
CO/P
90069
150
CO/P
90070
150
CO/P
90071
140
CO/P
90072
140
CO/P
90073
140
CO/P
90075
120
CO/P
90077
110
CO/P
90078
110
CO/P
90079
100
CO/P
90080
100
CO/P
90081
80
CO/P
90082
80
CO/P
90083
70
CO/P
90084
70
CO/P

Art.- Packaging- Article


no.
unit
group
90087
80
CS/P
90088
80
CS/P
90089
80
CS/P
90090
64
CS/P
90091
64
CS/P
90092
64
CS/P
90093
60
CS/P
90094
60
CS/P
90095
60
CS/P
90096
48
CS/P
90097
48
CS/P
90098
48
CS/P
90099
48
CS/P
90100
48
CS/P
90101
48
CS/P
90102
40
CS/P
90103
40
CS/P
90105
40
CS/P
90106
40
CS/P
90107
40
CS/P
90109
32
CS/P
90111
32
CS/P
90112
32
CS/P
90113
32
CS/P

Article
16
16
16
16
20
20
20
25
25
25
30
30
30
35
40
40
45
45
50
50
60
60

H
D Operating
M
A
(mm) (mm) voltage (thread) (mm)
16 20
220
M4
4
16 20
220
M5
4
16 20
220
M6
4
16 20
220
M8
4
20 20
400
M5
5
20 20
400
M6
5
20 20
400
M8
5
25 20
500
M5
6
25 20
500
M6
6
25 20
500
M8
6
30 20
600
M5
7
30 20
600
M6
7
30 20
600
M8
7
35 20
600
M6
7
40 20
600
M6
9
40 20
600
M8
10
45 20
750
M6
9
45 20
750
M8
10
50 20
750
M6
10
50 20
750
M8
10
60 20
750
M6
9
60 20
750
M8
9

Article
30
30
30
35
35
35
40
40
40
45
45
45
50
50
50
55
55
60
60
60
65
70
70
70

H
D Operating
M
A
(mm) (mm) voltage (thread) (mm)
30 30
750
M6
9
30 30
750
M8
9
30 30
750
M10
9
35 30
1000
M6
9
35 30
1000
M8
9
35 30
1000
M10
9
40 30
1000
M6
12
40 30
1000
M8
12
40 30
1000
M10 12
45 30
1000
M6
12
45 30
1000
M8
12
45 30
1000
M10 13
50 30
1500
M6
12
50 30
1500
M8
13
50 30
1500
M10 12
55 30
1500
M6
12
55 30
1500
M8
11
60 30
1500
M6
12
60 30
1500
M8
16
60 30
1500
M10 20
65 30
1500
M8
18
70 30
1500
M6
14
70 30
1500
M8
18
70 30
1500
M10 18

Spacing isolators type CO/P, CS/P, CT/P, CPE


Operating temperature -40 C up to +130 C
Fire resistance

212

www.mbs-stromwandler.de

class UL94-VO

MBS AG

Spacing isolator type CT/P 40 mm dia.

Spacing isolator type CPE 60 mm dia.

CT/P diameter 40 mm

CPE diameter 60 mm

Made of Polyglass-Polyester material, reinforced


fibre glass, colour red, self extinguishing.

Made of Polyglass-Polyester material, reinforced


fibre glass, colour red, self extinguishing.

Art.Packagingno.
unit
90118
45
90119
45
90120
36
90121
36
90122
27
90123
27
90123M12
27
90124
27
90125
27
90126
27
90127
27
90127M12
27
90129
18
90130
18
90131
18
90131M12
18
90133
18
90134
18
90135
18

Article
group
CT/P
CT/P
CT/P
CT/P
CT/P
CT/P
CT/P
CT/P
CT/P
CT/P
CT/P
CT/P
CT/P
CT/P
CT/P
CT/P
CT/P
CT/P
CT/P

Article
30
30
35
35
40
40
40
45
45
50
50
50
55
60
60
60
65
70
70

H
D Operating
M
A
(mm) (mm) voltage (thread) (mm)
30 40
750
M8
8
30 40
750
M10 9
35 40
750
M8
9
35 40
750
M10 9
40 40
1000
M8 12
40 40
1000
M10 12
40 40
1000
M12 12
45 40
1000
M8 13
45 40
1000
M10 12
50 40
1500
M8 12
50 40
1500
M10 13
50 40
1500
M12 11
55 40
1500
M10 12
60 40
1500
M8 18
60 40
1500
M10 18
60 40
1500
M12 18
65 40
1500
M10 18
70 40
1500
M8 18
70 40
1500
M10 18

Art.- Packaging- Article


no.
unit
group
90140
12
CPE
90141
12
CPE
90142
12
CPE
90143
10
CPE
90144
10
CPE
90145
10
CPE
90146
8
CPE
90147
8
CPE
90148
8
CPE
90149
5
CPE
90150
5
CPE
90151
5
CPE

Article
40
40
40
60
60
60
80
80
80
100
100
100

H
D Operating
M
A
(mm) (mm) voltage (thread) (mm)
40 60
1500
M10 11
40 60
1500
M12 11
40 60
1500
M16 12
60 60
3000
M10 18
60 60
3000
M12 18
60 60
3000
M16 19
80 60
5000
M10 19
80 60
5000
M12 19
80 60
5000
M16 23
100 60
8000
M10 19
100 60
8000
M12 19
100 60
8000
M16 23

CS/P 30 CS/P 40 CS/P 50 CS/P 60 CT/P 30 CT/P 40 CT/P 50 CT/P 60 CPE 40 CPE 60 CPE 80 CPE 100 CO/P 30 CO/P 40 CO/P 50 CO/P 60
resistance voltage tracking [kV]
8
8
10
15
8
10
10
10
10
20
25
30
5
8
10
10
discharge voltage
[kV] 20
25
35
35
20
25
35
35
25
50
50
50
15
20
25
30
max. tensile load
FZ [kN]
9
9
9
9
10
10
10
10
11
15
23
30
4
4
4
4
max. bending load
FB [kN] 4.5
3
2
1.5
7.5
7
5
3.7
7
5
9
15
2
1.5
1
1
max. compression load
FD[kN] 40
40
40
40
80
80
80
80
100
100
120
150
21
21
21
21
max. starting torque
MD[Nm] 1.3...2.6 1.3...2.6 1.3...2.6 1.3...2.6 3.0...6.0 3.0...6.0 3.0...6.0 3.0...6.0 6
8
10
15
1.0...2.0 1.0...2.0 1.0...2.0 1.0...2.0

www.mbs-stromwandler.de

213

MBS AG

Passing isolators type PI/P

Vertical bus bar support type PSB

panel bore

Art.no.
90166
90167
90168
90169
90170
90171
90172

Packagingunit
60
40
25
20
15
8
4

Article
group
PI/P
PI/P
PI/P
PI/P
PI/P
PI/P
PI/P

Article
4
6
8
10
12
16
20

H
D Operating
(mm) (mm) voltage
50
15
600
65
22
1000
80
25
1000
95
30
1000
105 35
1000
135 43
2000
155 54
2000

Passing isolator type PI/P


Polyester material, red

214

www.mbs-stromwandler.de

M
(thread)
M4
M6
M8
M10
M12
M16
M20

Easy to assemble vertical bus bar support in


Polyestermaterial with reinforced fibre glass, red, suitable
for bus bars with dimensions between 40 x 60 mm and
120 x 10 mm.
Due of its construction characteristics this bus bar
support is suitable for special isolating and mechanical
resistance requirements.
For the assembly of a bus bar support the following
parts are required:
1 or 2 lateral supports, 2 mounting screws and the
necessary blocknumber to clamp into place the required
bus bars.

MBS AG

PSB/1

PSB/6

lateral support

block for 6 mm bus bar

PSB/2

PSB/8

lateral support

block for 8 mm bus bar

PSB/120

PSB/10

lateral support

block for 10 mm bus bar

Lateral support Blocks


PSB/1
PSB 6
PSB 8
PSB 10
PSB/2
PSB 6
PSB 8
PSB 10
PSB/120
PSB 6
PSB 8
PSB 10

60 x 6
60 x 8
60 x 10
40 x 6
40 x 8
40 x 10
120 x 6
120 x 8
120 x 10

Bus bars
Art.-no.
80 x 6 100 x 6
80 x 8 100 x 8
90175*
80 x 10 100 x 10
50 x 6
50 x 8
90176*
50 x 10

Elastic deviation of the teeth with signs of rupture Pack. Art.-no.


PSB/6
kg
950
36
90178*
PSB/8
kg
1130
30
90179*
PSB/10
kg
1375
24
90180*

90177*

* = storage parts

Operating voltage

1000 V AC

Operating temperature -40 C ) ) +130 C


Fire resistance

class UL94-VO

www.mbs-stromwandler.de

215

MBS AG

Vertical bus bar support PSB


illustration 1
example of a unipolar bus bar support with 3 parallel bus bar
support holders

A = number of blocks
B = bus bar thickness
C = length of mounting
screw

L = external space
requirement
H = height
M = module

Illustrations 123456
show some of the possible variations
illustrations up to max. 10 x 100 mm

ill. 1a

ill. 1b

ill. 2

ill. 3

ill. 4

ill. 5

Art.no.
90175
90176
90177

Packagingunit
96
144
244

Article
group
PSB/1
PSB/2
PSB/120

H
(mm)
177
127
177

D
(mm)
46
46
35

Operating
voltage
1000
1000
1000

For
thread
M10
M10
M10

90178
90179
90180

36
30
24

PSB/6
PSB/8
PSB/10

37
38
38

36
48
60

1000
1000
1000

M10
M10
M10

Art.no.
90187
90188
90189
90190
90191
90192
90193
90194
90195
90196
90197
90198
90199
90200
90201
90202
90203
90204
90205
90206
90207
90211
90212
90213
90214
90215
90216
90217
90218
90219
90220
90221
90222
90223
90224
90225
90226
90227
90228
90229
90230
90231

Packaging- Article
unit
group
PSB
PSB
PSB
PSB
PSB
PSB
PSB
PSB
PSB
PSB
PSB
PSB
PSB
PSB
PSB
PSB
PSB
PSB
PSB
PSB
PSB
PSB
PSB
PSB
PSB
PSB
PSB
PSB
PSB
PSB
PSB
PSB
PSB
PSB
PSB
PSB
PSB
PSB
PSB
PSB
PSB
PSB

IllustraH
L
Operating
tion
(mm) (mm) voltage
ill. 1A 177
1000
ill. 1A 177
1000
ill. 1A 177
1000
ill. 1B 177 162
1000
ill. 1B 177 174
1000
ill. 1B 177 186
1000
ill. 2
177 198
1000
ill. 2
177 222
1000
ill. 2
177 246
1000
ill. 3
177 234
1000
ill. 3
177 270
1000
ill. 3
177 306
1000
ill. 4
177 270
1000
ill. 4
177 318
1000
ill. 4
177 366
1000
ill. 5
177 306
1000
ill. 5
177 366
1000
ill. 5
177 426
1000
ill. 5
177 342
1000
ill. 5
177 414
1000
ill. 5
177 486
1000
ill. 1A 127
1000
ill. 1A 127
1000
ill. 1A 127
1000
ill. 1B 127 152
1000
ill. 1B 127 164
1000
ill. 1B 127 176
1000
ill. 2
127 188
1000
ill. 2
127 212
1000
ill. 2
127 236
1000
ill. 3
127 224
1000
ill. 3
127 260
1000
ill. 3
127 296
1000
ill. 4
127 260
1000
ill. 4
127 308
1000
ill. 4
127 356
1000
ill. 5
127 296
1000
ill. 5
127 356
1000
ill. 5
127 416
1000
ill. 6
127 332
1000
ill. 6
127 404
1000
ill. 6
127 476
1000

For
thread
M10
M10
M10
M10
M10
M10
M10
M10
M10
M10
M10
M10
M10
M10
M10
M10
M10
M10
M10
M10
M10
M10
M10
M10
M10
M10
M10
M10
M10
M10
M10
M10
M10
M10
M10
M10
M10
M10
M10
M10
M10
M10

B
6
8
10
6
8
10
6
8
10
6
8
10
6
8
10
6
8
10
6
8
10
6
8
10
6
8
10
6
8
10
6
8
10
6
8
10
6
8
10
6
8
10

ill. 6

H.

with lateral support

M.

with block

216

PSB/1
PSB/2
PSB/6
PSB/8
PSB/10

= 177 mm
= 127 mm
= 36 mm
= 48 mm
= 60 mm

www.mbs-stromwandler.de

The above mentioned data are only for information purposes


and are without a guarantee. The customer is required to check
from time to time if the product is suitable for the required
application.
Upon request milled bus bar supports and other from GPO-3
extracted details can be supplied.
In this instance drawings are to be submitted.

MBS AG

Mounting material / threaded bolts


GB
threaded bolt

hexagon screw
M10 with nut and
washer

threaded bolt
M10 complete
with nut and
washer

Hexagon spacer in brass

Art.- Packaging- Article


no.
unit
group
90270
100
GB
90271
100
GB
90272
100
GB
90273
100
GB
90274
100
GB
90275
100
GB
90276
100
GB
90277
100
GB
90278
100
GB
90279
100
GB
90280
100
GB
90281
100
GB
90282
100
GB
90283
100
GB
90284
100
GB
90285
100
GB
90286
100
GB
90287
100
GB
90288
100
GB
90289
100
GB
90290
100
GB
90291
100
GB
90292
100
GB
90293
100
GB
90294
100
GB
90295
100
GB
90296
100
GB
90297
100
GB
90298
100
GB
90299
100
GB
90300
100
GB
90301
100
GB
90326
100
GB
90327
100
GB

Thread
M
M3
M3
M4
M4
M4
M4
M5
M5
M5
M5
M6
M6
M6
M6
M6
M6
M8
M8
M8
M8
M8
M8
M8
M8
M10
M10
M10
M10
M10
M10
M12
M12
M16
M16

Length
L (mm)
12
15
15
16
18
20
20
22
27
30
18
20
25
27
33
35
20
23
25
30
33
35
38
50
30
35
38
40
45
50
30
50
40
60

Art.- Packaging- Article


no.
unit
group
90309
100
SKS
90310
100
SKS
90311
100
SKS
90312
100
SKS
90313
100
SKS
90314
100
SKS
90315
100
SKS
90316
100
SKS
90317
100
SKS

Thread
M
M10
M10
M10
M10
M10
M10
M10
M10
M10

Length
L (mm)
60
80
70
90
100
110
140
150
160

Art.no.
90318
90319
90320
90321
90322
90323
90324
90325

Thread
M
M10
M10
M10
M10
M10
M10
M10
M10

Length
L (mm)
194
230
242
270
290
350
410
1000

Packingunit
100
100
100
100
100
100
100
100

Articlegroup
GB
GB
GB
GB
GB
GB
GB
GB

SK

Art.no.

Packagingunit

Thread
M

90330
90331
90332
90333
90334
90335
90336
90337
90338
90339
90340
90341
90342
90343
90344
90345
90346
90347
90348
90349
90350
90351
90352
90353
90354
90355
90356
90357

100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100

M4
M4
M4
M4
M4
M4
M4
M5
M5
M5
M5
M5
M5
M5
M6
M6
M6
M6
M6
M6
M6
M8
M8
M8
M8
M8
M8
M8

Height
H
mm
15
20
25
30
50
70
90
15
20
25
30
50
70
90
15
20
25
30
50
70
90
15
20
25
30
50
70
90

Wrench
opening
SW*
7
7
7
7
7
7
7
8
8
8
8
8
8
8
10
10
10
10
10
10
10
13
13
13
13
13
13
13

* SW = Screw Width

www.mbs-stromwandler.de

217

MBS AG

Bus bar support L


support L185/1

Art.-no. 90392
500 (600)
30

185

20

50

185

125

200

125

50

support L185/2 (2 x M10 each phase)


185

70

70

g
short-circuit protection L185/2

g
short-circuit protection L185/1
310

p
rated current surge lpk in kA

rated current surge lpk in kA

250

Characteristics of the raw materials (GFK-profile, hot hardened)


temperature range
-40 C up to +130 C
operating AC voltage
1000 Volt
continuous current
L/Z 280 mm
2500 A
L/Z 500 mm
4000 A
phase clearance
L/Z 280 mm
100 mm
L/Z 500 mm
185 mm
form stability
DIN 53462
C > 200
natural density
DIN 53479
gr/cm2 approx.1.7
fire resistance
UL 94
HB
discharge resistance
DIN 53481
kV/cm 10
resistance voltage tracking DIN IEC 112 CTI 600
specific flow resistance
DIN 53482
Ohm x cm 1012

230
fr Cu-Schienen
for copper bars
> 40 x 10

210
190
170
150
130

290

250
230
210
190

30

40

50 60 70 80
support-width (cm)

90

150
20

100

All bus bars are type tested acc. to VDE 0660 part 500
torque for M10 approx. 4.5 Nm
copper bus bar 10 mm thick made of copper F30
not nickle-plated

support L100

g
short-circuit protection L100

Art.-no. 90392
280

30
5

100

20

50

M8

75

100

75

50

rated current surge lpk in kA

190

100

170

fr Cu-Schienen
for copper bars
> = 30 x 10

150
130
110
90
70
50
30
20

Type

Art.- Packaging- Article Length Profile


no.
unit
group (mm)
(mm)
L100
90391
1
L
280 50/50
L185/1 90392
1
L
500 50/50
L185/2 90395
1
L
500 50/50

218

www.mbs-stromwandler.de

Bore
(mm)
7
7
7

Thread Colour
M
M8

M10

M10

fr Cu-Schienen
for copper bars
100 x 10 160 x 10

270

170

110
80
20

Art.-no. 90395

185

70

Bus bar supports in general

M10

30

40

50 60 70 80
support-width (cm)

90

100

30

40 50 60 70 80
support-width (cm)

90

100

MBS AG

Bus bar support L


support Z185/1

Art.-no. 90382
500
40

125

200

55

30

14

15

125

M10
185

185

support Z185/2 (2 x M10 each phase)


185

70

Art.-no. 90385

185

70

70

Bus bar supports in general


Characteristics of the raw materials (GFK-profile, hot hardened)
temperature range
-40 C up to +130 C
operating AC voltage
1000 Volt
continuous current
L/Z 280 mm
2500 A
L/Z 500 mm
4000 A
phase clearance
L/Z 280 mm
100 mm
L/Z 500 mm
185 mm
form stability
DIN 53462
C > 200
natural density
DIN 53479
gr/cm2 approx.1.7
fire resistance
UL 94
HB
discharge resistance
DIN 53481
kV/cm 10
resistance voltage tracking DIN IEC 112 CTI 600
specific flow resistance
DIN 53482
Ohm x cm 1012
All bus bars are type tested acc. to VDE 0660 part 500
torque for M10 approx. 4.5 Nm
copper bus bar 10 mm thick made of copper F30
not nickle-plated

support Z100

Art.-no. 90381
280
100

40

75

55

14

30

15

75

M8
100

Type

100

Art.- Packaging- Article Length


Profile
Bore
no
unit
group (mm)
(mm)
(mm)
Z100 90381
1
Z
280 30/40/30 7
Z185/1 90382
1
Z
500 30/40/30 7
Z185/2 90385
1
Z
500 30/40/30 7

Thread Colour
M
M8

M10

M10

www.mbs-stromwandler.de

219

MBS AG

MBS AG

Additional products
Shunts

Amperemeter change-over switch

Voltmeter change-over switch

NEOZED fuse base

Contact tongue

www.mbs-stromwandler.de

221

MBS AG

MBS AG

Shunts
Technical data:
Operating conditions
working temperature range -10 ) ) + 55 C
storage temperature
-25 ) ) + 65 C
relative air humidity
(no dewing)
) 75 %
climatic adaptability
climatic class 3
acc. VDE/VDI 3540
Accuracy
accuracy class

Material
resistance bars
connection units
construction type A
construction type B/C

class 0.5
(class 0.2 upon request)

manganin
brass
copper

Connections
current phase
voltage phase

refer to drawings
M5x8

Dimensions

refer to drawings

Protection

IP 00

Material profile of the connection units


construction type A
with isolating base (25 A)
without isolating base
(30150 A)
construction type B
L-profile
construction type C
T-profile
Weight

Type
nominal rated voltage drop

nominal current
Accuracy
Isolation base

Cap
Special configuration**)

Application
Shunts are being used for the indirect monitoring of high
electrical currents. The production of the shunts conform
to the requirements of DIN 43704 for currents from 1 A
up to 20 kA and voltage drops from 60 mV up to 300 mV.
Upon request additional ranges can be supplied where
the nominal values of current and voltage drop deviate
from the DIN series.
Function principle
The current flowing through the shunts create a voltage
drop, which can be measured with a measuring device
switched in parallel. With parallel switching the shunts
and the measuring devices, it is possible to use voltage
measurement devices to measure the current, or to gain
an extension of the measuring facilities of the existing
current measuring units. The shunts are manufactured in
three different versions, to accommodate the nominal
currents.
Production regulations
DIN 43703
Shunts
DIN 43780
direct active, signalling measuring units
and accessories
Special configurations
nominal rated voltage drop
nominal current
accuracy class
isolation base

acc. to customers information


acc. to customers information
0.2
for shunts
30200 A/60 mV

upon request
Order details
Shunts
60 mV
100 mV
150 mV
300 mV
acc. to customers information**)
see table in the data part
acc. to customers information**)
class 0.5 *)
class 0.2 upon request
for construction type A standard bus bars snap-on mountings can be supplied
125 A standard
30200 A (60 mV) accessories
125 A (60 mV; 100 mV; 150 mV) accessories
30200 A (60 mV) accessories
upon request

*) standard **) exact data are required


Order example:
shunt, nominal rated voltage drop 60 mV, nominal current 1000 A, class 0.5
technical amendments may be made (without prior notice)
www.mbs-stromwandler.de

223

MBS AG

Shunts
Construction type A

Nominal rated voltage drop 60 mV


Size
125 A 40150 A
a
90
100
b
78
80
c
20
20
d
8
8
e
M 5 x 12
M 8 x 16

Nominal rated voltage drop 100 mV


Size
125 A 40150 A
a
90
145
b
78
125
c
20
25
d
8
8
e
M 5 x 12
M 8 x 16

Nominal rated voltage drop 150 mV


Size
125 A 40150 A
a
90
225
b
78
205
c
20
25
d
8
8
e
M 5 x 12
M 8 x 16

Dimensions for 125 A

224

www.mbs-stromwandler.de

Nominal rated voltage drop 300 mV


Size
125 A 40150 A
a
90
385
b
78
364
c
20
25
d
8
8
e
M 5 x 12
M 8 x 16

MBS AG

Shunts
Construction type A

Construction type A
Art.-no.

Base

Type

71911
71911S
71912
71912S
71913
71913S
71914
71914S
71915
71915S
71916
71916S
71917
71917S
71918
71918S
71919
71919S
71920
71920S
71921
71921S
71922
71922S

without
with
without
with
without
with
without
with
without
with
without
with
without
with
without
with
without
with
without
with
without
with
without
with

SHUNT
SHUNT
SHUNT
SHUNT
SHUNT
SHUNT
SHUNT
SHUNT
SHUNT
SHUNT
SHUNT
SHUNT
SHUNT
SHUNT
SHUNT
SHUNT
SHUNT
SHUNT
SHUNT
SHUNT
SHUNT
SHUNT
SHUNT
SHUNT

60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60

72911
72911S
72912
72912S
72913
72913S
72914
72914S
72915
72915S
72916
72916S
72917
72917S
72918
72918S
72919
72919S
72920
72920S
72921
72921S
72922
72922S

without
with
without
with
without
with
without
with
without
with
without
with
without
with
without
with
without
with
without
with
without
with
without
with

SHUNT
SHUNT
SHUNT
SHUNT
SHUNT
SHUNT
SHUNT
SHUNT
SHUNT
SHUNT
SHUNT
SHUNT
SHUNT
SHUNT
SHUNT
SHUNT
SHUNT
SHUNT
SHUNT
SHUNT
SHUNT
SHUNT
SHUNT
SHUNT

100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100

Nominal
current
1A
1A
1.5 A
1.5 A
2.5 A
2.5 A
4A
4A
6A
6A
10 A
10 A
15 A
15 A
25 A
25 A
40 A
40 A
60 A
60 A
100 A
100 A
150 A
150 A
1
1
1.5
1.5
2.5
2.5
4
4
6
6
10
10
15
15
25
25
40
40
60
60
100
100
150
150

A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A

Construction type A
Nominal
voltage
drop
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100

mV
mV
mV
mV
mV
mV
mV
mV
mV
mV
mV
mV
mV
mV
mV
mV
mV
mV
mV
mV
mV
mV
mV
mV

Art.-no.

Base

Type

73911
73911S
73912
73912S
73913
73913S
73914
73914S
73915
73915S
73916
73916S
73917
73917S
73918
73918S
73919
73919S
73920
73920S
73921
73921S
73922
73922S

without
with
without
with
without
with
without
with
without
with
without
with
without
with
without
with
without
with
without
with
without
with
without
with

SHUNT
SHUNT
SHUNT
SHUNT
SHUNT
SHUNT
SHUNT
SHUNT
SHUNT
SHUNT
SHUNT
SHUNT
SHUNT
SHUNT
SHUNT
SHUNT
SHUNT
SHUNT
SHUNT
SHUNT
SHUNT
SHUNT
SHUNT
SHUNT

150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150

74911
74911S
74912
74912S
74913
74913S
74914
74914S
74915
74915S
74916
74916S
74917
74917S
74918
74918S
74919
74919S
74920
74920S
74921
74921S
74922
74922S

without
with
without
with
without
with
without
with
without
with
without
with
without
with
without
with
without
with
without
with
without
with
without
with

SHUNT
SHUNT
SHUNT
SHUNT
SHUNT
SHUNT
SHUNT
SHUNT
SHUNT
SHUNT
SHUNT
SHUNT
SHUNT
SHUNT
SHUNT
SHUNT
SHUNT
SHUNT
SHUNT
SHUNT
SHUNT
SHUNT
SHUNT
SHUNT

300
300
300
300
300
300
300
300
300
300
300
300
300
300
300
300
300
300
300
300
300
300
300
300

Nominal
current
1A
1A
1.5 A
1.5 A
2.5 A
2.5 A
4A
4A
6A
6A
10 A
10 A
15 A
15 A
25 A
25 A
40 A
40 A
60 A
60 A
100 A
100 A
150 A
150 A
1
1
1.5
1.5
2.5
2.5
4
4
6
6
10
10
15
15
25
25
40
40
60
60
100
100
150
150

A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A

www.mbs-stromwandler.de

Nominal
voltage
drop
150 mV
150 mV
150 mV
150 mV
150 mV
150 mV
150 mV
150 mV
150 mV
150 mV
150 mV
150 mV
150 mV
150 mV
150 mV
150 mV
150 mV
150 mV
150 mV
150 mV
150 mV
150 mV
150 mV
150 mV
300
300
300
300
300
300
300
300
300
300
300
300
300
300
300
300
300
300
300
300
300
300
300
300

mV
mV
mV
mV
mV
mV
mV
mV
mV
mV
mV
mV
mV
mV
mV
mV
mV
mV
mV
mV
mV
mV
mV
mV

225

MBS AG

Shunts
Construction type B

Size
a
b
c
d
e
f
g
no. of
current
connect.

Size
a
b
c
d
e
f
g
no. of
current
connect.

Nominal rated voltage drop 60 mV


250 A
400 A
1000 A
1500 A
2500 A
600 A
145
145
165
165
165
105
105
115
115
115
30
40
60
90
120
30
30
30
30
30
15
20
30
21
30
48
60
M 12 x 40 M 16 x 45 M 20 x 50 M 16 x 45 M 20 x 50
2x1

2x1

2x1

2x2

Nominal rated voltage drop 100 mV


250 A
400 A
1000 A
1500 A
600 A
190
190
210
210
150
150
160
160
30
40
60
120
30
30
30
30
15
20
30
30
60
M 12 x 40 M 16 x 45 M 20 x 50 M 20 x 50
2x1

2x1

2x1

2x2

Construction type B
Art.-no.

Base

Type

71923
71924
71925
71926
71996
71997

without
without
without
without
without
without

SHUNT
SHUNT
SHUNT
SHUNT
SHUNT
SHUNT

60
60
60
60
60
60

Nominal
current
250 A
400 A
600 A
1000 A
1500 A
2500 A

72923
72924
72925
72926
72935

without
without
without
without
without

SHUNT
SHUNT
SHUNT
SHUNT
SHUNT

100
100
100
100
100

250
400
600
1000
1500

A
A
A
A
A

Nominal
rated
voltage drop
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
100
100
100
100
100

mV
mV
mV
mV
mV

Size
a
b
c
d
e
g
no. of
current
connect.

Size
73923
73924
73925
73926

without
without
without
without

SHUNT
SHUNT
SHUNT
SHUNT

150
150
150
150

300
400
600
1000

A
A
A
A

150
150
150
150

mV
mV
mV
mV

74923
74924
74925
74926

without
without
without
without

SHUNT
SHUNT
SHUNT
SHUNT

300
300
300
300

250
400
600
1000

A
A
A
A

300
300
300
300

mV
mV
mV
mV

226

www.mbs-stromwandler.de

a
b
c
d
e
g
no. of
current
connect.

Nominal rated voltage drop 150 mV


250 A
400 A
1000 A
600 A
270
270
290
230
230
240
30
40
70
50
50
60
15
20
35
M 12 x 40 M 16 x 45 M 20 x 50
2x1

2x1

2x1

Nominal rated voltage drop 300 mV


250 A
400 A
1000 A
600 A
429
429
449
389
389
399
30
40
70
50
50
60
15
20
35
M 12 x 40 M 16 x 45 M 20 x 50
2x1

2x1

2x1

2x2

MBS AG

Shunts
Construction type C

Size
a
b
c
d
e
f
g
h
no. of
current
connect.

Size
a
b
c
d
e
f
g
h
no. of
current
connect.

Construction type C
Art.-no.

Base

71927 *
71928
71929
71930
71931
71932

without
without
without
without
without
without

Type
SHUNT
SHUNT
SHUNT
SHUNT
SHUNT
SHUNT

60
60
60
60
60
60

Nominal
current
1500 A
2500 A
4000 A
6000 A
1000 A
1500 A

72928
72929
72930

without SHUNT 100


without SHUNT 100
without SHUNT 100

73927
73928
73929
73930
73931

without
without
without
without
without

SHUNT
SHUNT
SHUNT
SHUNT
SHUNT

150
150
150
150
150

1500
2500
4000
6000
10000

A
A
A
A
A

150
150
150
150
150

mV
mV
mV
mV
mV

74927
74928
74929
74930

without
without
without
without

SHUNT
SHUNT
SHUNT
SHUNT

300
300
300
300

1500
2500
4000
6000

A
A
A
A

300
300
300
300

mV
mV
mV
mV

* special configuration

2500 A
4000 A
6000 A

Nominal
rated
voltage drop
60 mV
60 mV
60 mV
60 mV
60 mV
60 mV
100 mV
100 mV
100 mV

Size
a
b
c
d
e
f
g
h
no. of
current
connect.

Size
a
b
c
d
e
f
g
h
no. of
current
connect.

Nominal rated voltage drop 60 mV


4000 A
6000 A 10000 A 15000 A
165
175
185
185
115
125
135
135
120
154
206
310
60
130
170
170
30
25
25
25
60
52
52
52
M 20 x 60 M 20 x 75 M 20 x 80 M 20 x 80
15
25
30
30
2x2

2x3

2x4

2x6

Nominal rated voltage drop 100 mV


2500 A
4000 A
6000 A
210
220
220
160
170
170
120
120
154
60
130
130
30
30
25
60
60
52
M 20 x 50 M 20 x 50 M 20 x 75
15
25
25
2x2

2x2

2x3

Nominal rated voltage drop 150 mV


1500 A
2500 A
4000 A
6000 A 10000 A
290
290
300
300
310
240
240
250
250
260
90
120
120
154
206
60
60
130
130
170
21
30
30
25
25
48
60
60
52
52
M 16 x 60 M 20 x 60 M 20 x 75 M 20 x 75 M 20 x 80
15
15
25
25
30
2x1

2x1

2x2

2x3

2x4

Nominal rated voltage drop 300 mV


1500 A
2500 A
4000 A
6000 A
449
449
459
459
399
399
409
409
90
120
120
154
60
60
130
130
31
30
30
25
48
60
60
52
M 16 x 60 M 20 x 60 M 20 x 75 M 20 x 75
15
15
25
25
2x1

2x2

2x2

www.mbs-stromwandler.de

2x3

227

MBS AG

Additional products
Amperemeter change-over switch
Amperemeter change-over switch
amperemeter change-over switch with 0-position
amperemeter change-over switch without 0-position

Art.-no.
59061
59062

Voltmeter change-over switch


Voltmeter change-over switch
voltmeter change-over switch
voltmeter change-over switch

with 0-position
without 0-position

Art.-no.
59060
59063

NEOZED fuse base

NEOZED fuse base


Art.-no.
59011

fuse base 10 A

Contact tongue

thread M5

228

www.mbs-stromwandler.de

Contact tongue
Length
Depth
38
2

Width
24

Art.-no.
59055

MBS AG

Voltage transformers
MBEV
MBER
MBE

1-pole isolated

MBZV
MBZR
MBZ

2-pole isolated

www.mbs-stromwandler.de

229

MBS AG

Voltage transformers
1-pole isolated
Rated voltage
Type
Accuracy class
Burden
Primary V
100/ 3
110/ 3
220/ 3
380/ 3
400/ 3
500/ 3
600/ 3
800/ 3
1000/ 3

Secondary rated voltage 100 V / 3 3 V


MBEV 6 MBEV 10 MBEV 20 MBEV 50 MBEV 100
1
0.5 / 1
0.5 / 1
0.5 / 1
0.5 / 1
VA 3
VA 5 / 10 VA 10 / 20 VA 25 / 50 VA 50 / 100
Art.-no.
Art.-no.
Art.-no.
Art.-no.
Art.-no.
SEV1001 SEV1010 SEV1019 SE V1028 SEV1037
SEV1002 SEV1011 SEV1020 SEV1029 SEV1038
SEV1003 SEV1012 SEV1021 SEV1030 SEV1039
SEV1004 SEV1013 SEV1022 SEV1031 SEV1040
SEV1005 SEV1014 SEV1023 SEV1032 SEV1041
SEV1006 SEV1015 SEV1024 SEV1033 SEV1042
SEV1007 SEV1016 SEV1025 SEV1034 SEV1043
SEV1026 SEV1035 SEV1044
SEV1027 SEV1036 SEV1045

3
3
3
3
3
3
3
3
3

2-pole isolated
Rated voltage
Type
Accuracy class
Burden
Primary V
100
110
220
380
400
500
600
800
1000

Secondary rated voltage 100 V


MBZV 6 MBZV 10 MBZV 20 MBZV 50 MBZV 100
1
0.5 / 1
0.5 / 1
0.5 / 1
0.5 / 1
VA 6
VA 10 / 20 VA 20 / 40 VA 50/ 100 VA 100 / 200
Art.-no.
Art.-no.
Art.-no.
Art.-no.
Art.-no.
SZV1001 SZV1010 SZV1019 SZ V1028 SZV1037
SZV1002 SZV1011 SZV1020 SZV1029 SZV1038
SZV1003 SZV1012 SZV1021 SZV1030 SZV1039
SZV1004 SZV1013 SZV1022 SZV1031 SZV1040
SZV1005 SZV1014 SZV1023 SZV1032 SZV1041
SZV1006 SZV1015 SZV1024 SZV1033 SZV1042
SZV1007 SZV1016 SZV1025 SZV1034 SZV1043
SZV1026 SZV1035 SZV1044
SZV1027 SZV1036 SZV1045

standard
max. voltage for equipment
test voltage
rated frequency
place of application
climatic conditions
mechanical conditions
vibration proof
isolating class
housing protection class
isolating material

230

Technical data of the standard design


IEC 60044-2
0.72 kV up to 600 V - 1.2 kV up to 1000 V
0.72 kV / 3 kV; 1 kV / 6 kV
50 / 60 Hz
indoors up to 2000 m above normal sea level
IEC 60721-3-3 3K4
IEC 60721-3-3 3M3
IEC 60068-2
2.5 g (25...100 Hz)
IEC 60085
E (120 C)
IEC 60529
housing: IP 50
terminals with cover: IP 20
UL E44423
copper coated wire
UL E47960
winding contacts
UL E93687
isolation coating
UL E51047
imprinted coating

Type
MBEV 6
MBEV 10
MBEV 20
MBEV 50
MBEV 100

A
140
165
175
195
210

B
85
90
90
105
128

Housing in
C
D
100 125
105 145
105 155
125 175
155 190

MBZV 6
MBZV 10
MBZV 20
MBZV 50
MBZV 100

140
165
175
195
210

85
90
90
105
128

100
105
105
125
155

www.mbs-stromwandler.de

125
145
155
175
190

mm
E
68
70
70
81
101

F
52
67
82
95
97

G
4.5
4.5
4.5
5.5
8

68
70
70
81
101

52
67
82
95
97

4.5
4.5
4.5
5.5
8

Weight
kg
Standard accessories
2.3
3
4.1
terminal covers
6
8
2.3
3
4.1
6
8

terminal covers

MBS AG

Voltage transformers
1-pole isolated
Rated voltage
Primary V

Type

100 / 3
110 / 3
200 / 3
220 / 3
230 / 3
corresponding
isolation level
UM = 0.72 kV

MBER 60
MBER 70
MBER 100
MBER 104
MBE 100
MBE 150
MBE 150
MBE 150
MBE 150

380 / 3. 400 / 3
500 / 3. 600 / 3
660 / 3
corresponding
isolation level
UM = 0.72 kV

MBER 100
MBER 104
MBE 100
MBE 150
MBE 150
MBE 150
MBE 150

690 / 3
750 / 3
1000 / 3
corresponding
isolation level
UM = 1.2 kV

MBER 100/1
MBER 104/1
MBE 100/1
MBE 150/1
MBE 150/1
MBE 150/1
MBE 150/1

Size

Secondary rated voltage


Accuracy class
0.5
VA
Art.-no.
VA

0.5
0.5 SE1004
1
2.5 SE1008
5
15
SE1012
30
10
SE1015
15
20
SE1019
50
30
SE1023
60
50
SE1027 100
60
SE1031 120

1
2
3
4

VA

0.2
1
5

7.5
10
15
25

0.2
Art.-no.

SE1003
SE1007
SE1011

SE1018
SE1022
SE1026
SE1030

1
2
3
4

0.5
5

7.5
10
15
25

SE1034
SE1038

SE1045
SE1049
SE1053
SE1057

1.5
10
10
20
30
50
60

SE1035
SE1039
SE1042
SE1046
SE1050
SE1054
SE1058

1
2
3
4

7.5
10
15
20

SE1064

SE1071
SE1075
SE1079
SE1083

1
10
7.5
20
30
45
60

SE1061
SE1065
SE1068
SE1072
SE1076
SE1080
SE1084

100 V / 3V
1
Art.-no.
SE1001
SE1005
SE1009
SE1013
SE1016
SE1020
SE1024
SE1028
SE1032

VA
1.5
3
15
30
50
120
150
200
250

3
Art.-no.
SE1002
SE1006
SE1010
SE1014
SE1017
SE1021
SE1025
SE1029
SE1033

Pi
VA
0.3
0.6
1.5
2
5
10
12
15
20

L2th
A
0.6
0.8
1.2
0.9
1
3
3
3
3

3
25
15
50
60
100
120

SE1036
SE1040
SE1043
SE1047
SE1051
SE1055
SE1059

10
25
50
120
150
200
250

SE1037
SE1041
SE1044
SE1048
SE1052
SE1056
SE1060

1.5
2
5
10
12
15
20

1.2
0.9
1
3
3
3
3

2
25
15
45
60
90
100

SE1062
SE1066
SE1069
SE1073
SE1077
SE1081
SE1085

5
25
30
100
120
150
180

SE1063
SE1067
SE1070
SE1074
SE1078
SE1082
SE1086

1.5
2
5
10
12
15
20

1.2
0.9
1
3
3
3
3

additional charges for special configuarations


Auxiliary winding for production of
an open delta winding (VA rating of
measuring winding reduced by
approx. 30 %): / 3// 3/100 / 3
V

Interim voltage transformer for


production of an open delta winding
(without measuring winding):
100 / 3 /100 / 3 V

Type
MBE 150

Size

Long time current


1A/8h

Type
MBE
MBE
MBE
MBE

100
150
150
150

Size

1
2
3

Long time current


1A/8h
5A/8h
6A/8h
8A/8h

Type
MBE
MBE
MBE
MBE
MBE
MBE

(Z)
(Z)
(Z)
(Z)
(Z)
(Z)

Tropical design

Resin hardened

R 60
R 70
R 100 (/1)
R 104 (/1)
100 (/1)
150 (/1)

snap-on mountings for:


Type
MBE (Z) R 60
MBE (Z) R 70

joint foot mounting for:


Type
MBE (Z) R 70

additional special configurations upon request


www.mbs-stromwandler.de

231

MBS AG

Voltage transformers
2-pole isolated

Rated voltage
Primary V

100, 110, 200,


220, 230
corresponding
isolation level
UM = 0.72 kV

380, 400, 500,


600, 660
corresponding
isolation level
UM = 0.72 kV

690, 750, 1000


corresponding
isolation level
UM = 1.2 kV

Type

Size

MBZR 60
MBZR 70
MBZR 100
MBZR 104
MBZ 100
MBZ 150
MBZ 150
MBZ 150
MBZ 150
MBZR 60
MBZR 70
MBZR 100
MBZR 104
MBZ 100
MBZ 150
MBZ 150
MBZ 150
MBZ 150
MBZR 60/1
MBZR 70/1
MBZR 100/1
MBZR 104/1
MBZ 100/1
MBZ 150/1
MBZ 150/1
MBZ 150/1
MBZ 150/1

Secondary rated voltage


Accuracy class
0.5
VA
Art.-no.
VA
0.5 SZ1001
1
2.5 SZ1005
5
5
SZ1009
10
15
SZ1013
30
15
SZ1016
30
25
SZ1020
60
45
SZ1024
90
60
SZ1028 120
75
SZ1032 150

VA

1
2
5

10
15
20
30

0.2
Art.-no.

SZ1004
SZ1008
SZ1012

SZ1019
SZ1023
SZ1027
SZ1031

SZ1037
SZ1041
SZ1045

SZ1052
SZ1056
SZ1060
SZ1064

1
2
3
4

0.5
1.5
5

10
15
20
30

1.25
3
10
15
25
45
60
75

SZ1038
SZ1042
SZ1046
SZ1049
SZ1053
SZ1057
SZ1061
SZ1065

1
5

7.5
10
15
20

SZ1068
SZ1072

SZ1079
SZ1083
SZ1087
SZ1091

2.5
10
7.5
20
30
45
60

1
2
3
4
2

1
2
3
4

100 V
1
Art.-no.
SZ1002
SZ1006
SZ1010
SZ1014
SZ1017
SZ1021
SZ1025
SZ1029
SZ1033

VA
3
15
25
30
60
150
200
250
300

3
Art.-no.
SZ1003
SZ1007
SZ1011
SZ1015
SZ1018
SZ1022
SZ1026
SZ1030
SZ1034

Pi
VA
0.5
2
2.5
3
9
12
15
18
24

L2th
A
0.4
0.5
0.8
0.9
1
3
3
3
3

1
2.5
10
25
30
60
90
120
150

SZ1035
SZ1039
SZ1043
SZ1047
SZ1050
SZ1054
SZ1058
SZ1062
SZ1066

3
7.5
20
25
60
150
200
250
300

SZ1036
SZ1040
SZ1044
SZ1048
SZ1051
SZ1055
SZ1059
SZ1063
SZ1067

0.5
1.5
2
2.5
9
12
15
18
24

0.4
0.5
0.8
0.9
1
3
3
3
3

SZ1069
SZ1073
SZ1076
SZ1080
SZ1084
SZ1088
SZ1092

5
25
15
50
60
100
120

SZ1070
SZ1074
SZ1077
SZ1081
SZ1085
SZ1089
SZ1093

15
25
30
120
150
200
250

SZ1071
SZ1075
SZ1078
SZ1082
SZ1086
SZ1090
SZ1094

0.5
1.5
1.5
2.5
9
12
15
18
24

0.4
0.5
0.8
0.9
0.8
2
2
2
2

* upon request

standard

Technical data of the standard design


IEC 60044-2
DIN VDE 0414 T.2

max. voltage for equipment


test voltage
rated frequency
place of application
climatic conditions
mechanical conditions
vibration proof
isolating class
housing protection class

232

www.mbs-stromwandler.de

IEC 721
IEC 721
IEC 68-2
DIN IEC 85
VDE 0301-1
IEC EN 60529
DIN VDE 0470

Um 0.72 kV MBE.... MBZ


(Um 1.2 kV ) MBE.../1. MBZ.../1
3 kV. 50 Hz. 1 min
(6 kV. 50 Hz. 1 min)
5060 Hz
indoors up to 2000 m
above normal sea level
3K4
3K3
2.5 g (25...100 Hz)
E 120 C
housing: IP 50
terminals with cover: IP 20

MBS AG

Voltage transformers
Type
MBZR 60 (/1)
MBZR 70 (/1)
MBZR 100 (/1)
MBZR 104 (/1)
MBZ 100 (/1)
MBZ 150 (/1)
MBZ 150 (/1)
MBZ 150 (/1)
MBZ 150 (/1)

Size
2

1
2
3
4

Width
60
70
100
104
102
150
150
150
150

Housing in mm
Height
Depth
H
78
52
86
52
118
73
127
75
105
123
123
123
123

111
142
152
162
182

40
50
60
80

Weight
kg
0.5
0.6
1.1
2.0

Standard accessories
foot mounting
terminal covers

3.1
7.0
8.0
9.0
11.5

MBZR 60 (/1)
(MBER 60)

MBZR 70 (/1)
(MBER 70)

MBZR 100 (/1)


(MBER 100)

MBZR 104 (/1)


[MBER 104 (/1)]

Order example
type:
rated measuring ratio:
rated burden:
accuracy class:
art.-no.:

MBZR 60
200/100 V
0.5 VA
0.5
SZ1001-200

www.mbs-stromwandler.de

233

MBS AG

Voltage transformers
Type
MBER 60 (/1)
MBER 70 (/1)
MBER 100 (/1)
MBER 104 (/1)
MBE 100 (/1)
MBE 150 (/1)
MBE 150 (/1)
MBE 150 (/1)
MBE 150 (/1)

Size
2

1
2
3
4

Width
60
70
100
104
102
150
150
150
150

Housing in mm
Height
Depth
78
52
86
52
118
73
127
75
105
123
123
123
123

111
142
152
162
182

40
50
60
80

Weight
kg
0.5
0.6
1.1
2.0
3.1
7.0
8.0
9.0
11.5

MBER 60, MBER 70, MBER 100(/1), MBER 104 (/1) drawings see page 219

MBE 100 (/1)


[MBZ 100 (/1)]

MBE 150 (/1)


[MBZ 150 (/1)]
size 1 size 4

Order example
type
rated measuring ratio
rated burden
accuracy class
art.-no.

234

MBE 100/1
750 3 /100 3
15 VA
1
SE1069-750

www.mbs-stromwandler.de

Standard accessories
foot mounting
terminal covers

MBS AG

Measuring transducers for all electrical AC-variables


Order List
page
SWMU

Measuring transducer for AC with integrated current transformer . . . . . . . . . . . . . . . . . . .236

NMC

Clip-on measuring transducers for MBS current transformers . . . . . . . . . . . . . . . . . . . . . .239

NMC-AD

Adaptors for current transformers of any make . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .241

NMC-KSx

Short circuit adaptors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .241

FASK

Flexible clip-on current transformers (Rogowski coil) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .242

EMBSIN

page

270

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .244

EMBSIN 100 IV

Measuring transducers for AC current, without auxiliary voltage supply . . . . . . . . . . . . . . .246

271

EMBSIN 100 I

Measuring transducers for AC current, without auxiliary voltage supply . . . . . . . . . . . . . . .247

271

EMBSIN 101 I

Measuring transducers for AC current, with auxiliary voltage supply . . . . . . . . . . . . . . . . .248

272

EMBSIN 201 IEV

Measuring transducers for AC current, rms measurement . . . . . . . . . . . . . . . . . . . . . . . . .249

273

EMBSIN 201 IE

Measuring transducers for AC current, rms measurement . . . . . . . . . . . . . . . . . . . . . . . . .250

275

EMBSIN 120 UV

Measuring transducers for AC voltage, without auxiliary voltage supply . . . . . . . . . . . . . .251

276

EMBSIN 120 U

Measuring transducers for AC voltage, without auxiliary voltage supply . . . . . . . . . . . . . . .252

276

EMBSIN 121 U

Measuring transducers for AC voltage, with auxiliary voltage supply . . . . . . . . . . . . . . . . .253

272

EMBSIN 221 UEV Measuring transducers for AC voltage, rms measurement . . . . . . . . . . . . . . . . . . . . . . . . .254

273

EMBSIN 221 UE

Measuring transducers for AC voltage, rms measurement

. . . . . . . . . . . . . . . . . . . . . . . .255

275

EMBSIN 241 FV

Measuring transducers for frequency, with auxiliary voltage supply . . . . . . . . . . . . . . . . . .256

277

EMBSIN 241 F

Measuring transducers for frequency with universal AC/DC power supply . . . . . . . . . . . . .257

278

EMBSIN 241 FD

Measuring transducers for frequency difference, with universal AC/DC power supply . . . .258

278

EMBSIN 271 G

Measuring transducers for phase angle, with universal AC/DC power supply . . . . . . . . . . .259

279

EMBSIN 271 GD

Measuring transducers for phase angle difference, with universal AC/DC power supply . . .260

281

EMBSIN 281 G

Measuring transducers for power factor, with universal AC/DC power supply . . . . . . . . . .261

279

EMBSIN 351 P

Measuring transducers for active power, with universal AC/DC power supply . . . . . . . . . .262

282

EMBSIN 361 Q

Measuring transducers for re-active power, with universal AC/DC power supply . . . . . . . .263

282

EMBSIN 301

Programmable measuring transducers for AC current, rms measurement . . . . . . . . . . . . .264

283

EMBSIN 391 PV

Programmable measuring transducers for all electrical variables . . . . . . . . . . . . . . . . . . . .265

283

EMBSIN 391

Programmable measuring transducers for electrical AC variables . . . . . . . . . . . . . . . . . . .267

SWMU

NMC

FASK

EMBSIN

www.mbs-stromwandler.de

235

MBS AG

SWMU
Measuring transducer for
alternating current
with or without auxiliary voltage supply
with integrated current transformer housing unit
for 35 mm DIN rail
Features/benefits
measuring input: Sinus-shaped AC current (1 A 800 A),
arithmetical mean value measurement, effective value calibrated
measuring output: Unipolar output signal
measurement principle: Rectifier process
with integrated current transformer
minimal wiring

The above photo of an SWMU 41.51


denotes a bus bar. This bus bar is not
included in the supply of the unit.

Application
Measuring transducers for the transformation of sinus-shaped AC current.
For an output signal a load-independent DC current / and an imprinted DC
voltage signal is available, which stands proportionally to the measurement
value of the input volume.
These signals can be used for display, recording, monitoring and/or control
function.
The measuring transducer fulfills the requirements and regulations with regard
to the electromagnetic compatibility (EMV) and security (IEC 1010 and EN
61010). This measuring transducer has been designed, produced, and tested in
accordance with ISO 9001.

Technical data SWMU 41.51/52 SWMU 42.51/52


measuring input
nominal frequency
rated input current I N
SWMU 41.52
SWMU 41.51
consumption
overload capacity

f N 50/60 Hz
1 ... 10 A
15 ... 800 A
) 1 VA (2.5 VA without
auxiliary voltage)
1.5 I N, constant
8 I N, 40 sec.

measuring output
load-independent DC current 0 ... 20 mA or
4 ... 20 mA*
max. burden resistance
) 500 1
max. burden voltage
) 15 V
current limit
under overload
) 34 mA
imprinted DC voltage
0 ... 10 V or
2 ... 10 V*
burden resistance
* 10 k1
max. burden voltage
under overload
) 18 V
voltage limit
) 18 V
residual ripple
of the output current
) 1 % p.p.
response time
) 500 ms
operating temperature range -5 C ) ) +40 C

236

www.mbs-stromwandler.de

auxiliary power
AC power supply
DC
power input
accuracy
reference value
accuracy class
warming-up time
protection
electrocution protection

contamination class
test voltages
(DIN 57411)

230 V 10 % (50 ... 60 Hz)


24 V 15 %
) 1.5 W (2.5 VA)
output end value
class 0.5
) 5 min.
IP 40, housing
(test wire, EN 60529)
IP 20, connection terminals
(test digit, EN 60529)
2
4 kV, activ circuits against housing
4 kV, auxiliary voltage against
measuring output (230 V-version)
500 V, auxiliary voltage against
measuring output (24 V-DC-version)

*Live-Zero only with auxiliary voltage

MBS AG

1. Auxiliary voltage 230 V AC


Type Primary
Measuring output
SWMU current 0...20 mA 4...20 mA 0...20 mA
and
and
and
A
0... 10 V
0... 10 V
2... 10 V
1
61006
62006
63006
41.52
5
61007
62007
63007
10
61008
62008
63008
special*
61100
62100
63100
15
61009
62009
63009
20
61010
62010
63010
25
61011
62011
63011
30
61012
62012
63012
40
61013
62013
63013
50
61014
62014
63014
60
61015
62015
63015
75
61016
62016
63016
100
61017
62017
63017
41.51
150
61018
62018
63018
200
61019
62019
63019
250
61020
62020
63020
300
61021
62021
63021
400
61022
62022
63022
500
61023
62023
63023
600
61024
62024
63024
750
61025
62025
63025
800
61026
62026
63026
special*
61200
62200
63200
measuring frequency 50/60 Hz
weight 350 g
* measuring range defined by customer

2. Auxiliary voltage 24 V DC

4...20 mA
and
2... 10 V
64006
64007
64008
64100
64009
64010
64011
64012
64013
64014
64015
64016
64017
64018
64019
64020
64021
64022
64023
64024
64025
64026
64200

Type
SWMU

41.52

41.51

Primary
current
A
1
5
10
special*
15
20
25
30
40
50
60
75
100
150
200
250
300
400
500
600
750
800
special*

Measuring output
0...20 mA 4...20 mA 0...20 mA 4...20 mA
and
and
and
and
0... 10 V
0... 10 V
2... 10 V 2... 10 V
65006
66006
67006
68006
65007
66007
67007
68007
65008
66008
67008
68008
65100
66100
67100
68100
65009
66009
67009
68009
65010
66010
67010
68010
65011
66011
67011
68011
65012
66012
67012
68012
65013
66013
67013
68013
65014
66014
67014
68014
65015
66015
67015
68015
65016
66016
67016
68016
65017
66017
67017
68017
65018
66018
67018
68018
65019
66019
67019
68019
65020
66020
67020
68020
65021
66021
67021
68021
65022
66022
67022
68022
65023
66023
67023
68023
65024
66024
67024
68024
65025
66025
67025
68025
65026
66026
67026
68026
65200
66200
67200
68200

measuring frequency 50/60 Hz


weight 250 g
* measuring range defined by customer

3. Without auxiliary voltage supply


Type
SWMU

42.52

42.51

Primary
current

A
1
5
special*
40
50
60
75
100
150
200
250
300
400
500
600
750
800
special*

Measuring output
0... 20 mA
and
0... 10 V
69006
69007
69100
69013
69014
69015
69016
69017
69018
69019
69020
69021
69022
69023
69024
69025
69026
69200

power requirements PE * 2.5 VA !


measuring frequency 50/60 Hz
weight 600 g
operating range 15120 % I N
* measuring range defined by customer

www.mbs-stromwandler.de

237

MBS AG

Basic circuit diagrams

SWMU 41.51

SWMU 41.52

SWMU 42.51

mounting base for direct fitting without use of a


35 mm DIN rail (included in the delivery content)

depth 50 (72) mm

238

www.mbs-stromwandler.de

MBS AG

NMC
Measuring transducer for AC currents
Clip-on measuring transducer for
MBS current transformers in modular construction,
versions with (NMC 2/3/4) or without
auxiliary voltage supply (NMC-0)
Features/benefits
measuring input: Sinus-shaped AC current (1 A or 5 A)
arithmetical mean value measurement, effective value calibrated
measuring output: Unipolar output signal
measurement principle: Rectifier process
direct notching with MBS current transformers through contact studs
economic wiring
Application
Measuring transducers for the transformation of sinus-shaped AC current. For
an output signal a load-independent DC current and an imprinted DC voltage
signal is available, which stands proportionally to the measurement value of
the input volume. These signals can be used for display, recording, monotoring and or control function.
Simultaneously, the secondary current of the current transformers can be
utilised to operate conventional needle instruments .
The measuring transducer fulfills the requirements and regulations with regard
to the electromagnetic compatibility (EMV) and security (IEC 1010 and EN
61010). This measuring transducer has been designed, produced, and tested
in accordance with ISO 9001.
Technical data NMC 0/2/3/4
measuring input
nominal frequency fN
rated input current I N
power input
from measuring circuit
overload capacity

50/60 Hz
1 A or 5 A
) 1 VA
(2.5 VA w/o auxiliary voltage)
1.2 I N, constant
8 I N, <40 sec.

measuring output
load-independent DC current 0 ... 20 mA or
4 ... 20 mA
max. burden resistance
500 1
max. burden voltage
) 15 V
current limit
under overload
) 34 mA
imprinted
0 ... 10 V or
DC voltage
2 ... 10 V*
min. burden resistance
*10 k1
max. burden voltage
under overload
) 18 V
residual ripple
of the output current
) 1 % p.p.
response time
< 500 ms

auxiliary power
AC power supply
DC
power input
accuracy
reference value
accuracy class
accuracy range
NMC 2/3/4
NMC 0
warming-up time
protection
electrocution protection

230 V 10 % (50 ... 60 Hz) or


110 V 10 % (50 ... 60 Hz)
24 V 15 %
)1.5 W (2.5 VA)
output end value
class 0.5
1 ... 120 % IN
15 ... 120 % IN
) 5 min.

IP 40, housing
(test wire, EN 60529)
IP 20, connection terminals
(test digit, EN 60529)
contamination class
2
test voltages
4 kV, activ circuits against housing
(DIN 57411)
4 kV, auxiliary voltage against
measurement outputs (230 V
AC-version)
500 V, auxiliary voltage against
measurement output
(24 V DC-version)
*Live-Zero only with auxiliary voltage

www.mbs-stromwandler.de

239

MBS AG
NMC measuring transducer for sinus-shaped alternating currents,
for clip-on onto MBS current transformer (rectifier-mean value
measurement)

drawings
A

Auxiliary voltage 24 V DC galvanically separated


Measuring outputs
Primary Suitable for
Type 0...20 mA 4...20 mA 4...20 mA current current transNMC
and
and
and
[A]
formers in the
(2)
0... 10 V
0... 10 V
2... 10 V
product range
211
39212
39232
39252
1
A
212
39213
39233
39253
1
B
213
39214
39234
39254
1
C
214
39215
39235
39255
1
D
221
39012
39032
39052
5
A
222
39013
39033
39053
5
B
223
39014
39034
39054
5
C
224
39015
39035
39055
5
D
measuring frequency 50/60 Hz; weight: 80 g; operating range 0 ... 120 % IN
Auxiliary voltage 230 V AC galvanically separated

B/C

Measuring outputs
Primary Suitable for
Type 0...20 mA 4...20 mA 4...20 mA current current transNMC
and
and
and
[A]
formers in the
(3)
0... 10 V
0... 10 V
2... 10 V
product range
311
36212
36232
36252
1
A
312
36213
36233
36253
1
B
313
36214
36234
36254
1
C
314
36215
36235
36255
1
D
321
36041
36032
36052
5
A
322
36042
36033
36053
5
B
323
36043
36034
36054
5
C
324
36044
36035
36055
5
D
measuring frequency 50/60 Hz; weight: 80 g; operating range 0 ... 120 % IN
Auxiliary voltage 110 V AC galvanically separated
Measuring outputs
Primary Suitable for
Type 0...20 mA 4...20 mA 4...20 mA current current transNMC
and
and
and
[A]
formers in the
(4)
0... 10 V
0... 10 V
2... 10 V
product range
411
76212
76232
76252
1
A
412
76213
76233
76253
1
B
413
76214
76234
76254
1
C
414
76215
76235
76255
1
D
421
76012
76032
76052
5
A
422
76013
76033
76053
5
B
423
76014
76034
76054
5
C
424
76015
76035
76055
5
D
measuring frequency 50/60 Hz; weight: 80 g; operating range 0 ... 120 % IN
Without auxiliary voltage supply, power requirements * 2.5 VA
Measuring outputs
Primary Suitable for
Type 0...20 mA
current current transNMC
and
[A]
formers in the
(0)
0... 10 V
product range
011
37212
1
A
012
37213
1
B
013
37214
1
C
014
37215
1
D
021
37012
5
A
022
37013
5
B
023
37014
5
C
024
37015
5
D
measuring frequency 50/60 Hz; weight: 80 g; operating range 15 ... 120 % I N

240

www.mbs-stromwandler.de

Comment: The dimensions of the measuring


transducer are relevant only for the adaption
to the existing current transformer construction
types. All units consist of the same electronic
modules.

MBS AG

NMC selection chart


Primary current
A
1
5
10
15
20
25
30
40
50
60
75
80
100
125
150
200
250
300
400
500
600
750
800
1000
1200
1250
1500
1600
2000
2500
3000

Construction type
B

WSK
30 WSK
40

ASK
ASK ASK 31.3
41.3 318.3
sec. 1
up to
300 A

ASK
421.4

ASK
21.3

ASR
22.3

ASK
ASK
412.4
41.4

ASK
61.4

ASK
63.4

ASK
81.4

ASK
101.4

ASK
105.6

NMC-AD
Adaptor for current transformers of any make to
clip onto 35 mm DIN rail
Features/benefits
accommodation of any make of current transformer in
connection with transducers of type NMC
direct mounting of measuring transducers, in visual devision
to the measuring point, onto an approved 35 mm DIN rail
Order instruction
36011
weight: 70 g

Application with NMC art.-no.


39xx2; 36xx1/2; 37xx2; 76xx2

connection
6, 7

description.
incoming terminals 5 A or 1 A
(sourced from current transformers)

Short circuit adaptor NMC-KSx


Application
Adaptors of type NMC-KSx are clipped onto current transformers. When the scondary circuit of a current transformer
is not being energized the adaptors prevent idling of the
transformer, and thus the occurrance of high neutral
voltages in the nominal current of the current transformer.

Type

Applicable with MBS current transformer types

NMC-KSx

Art.-no.

0
1
2
3

39090
39091
39092
39093

WSK WSK
30
40

ASR
22.3

ASK
21.3

ASK
31.3

ASK
41.3

ASK
41.4

ASK
421.4

ASK
61.4

ASK
63.4

ASK
81.4

ASK ASK Drawing


101.4 105.6
A
B
C
D

www.mbs-stromwandler.de

241

MBS AG

FASK
Flexible Clip-On Current Transformers

New

Measuring principle:

Rogowski Coil with or without integral integrator/amplifier

Application:

The FASK current transformer is manufactured to cover a wide range of


lengths, current ranges and output levels to standard or OEM specifications.
Very low phase errors with true rms voltage output from the integrator
enable the FASK Transformer to be used in a wide variety of current or
kW/kWh measurement applications.
Compared with the conventional iron cored CT, the FASK has minimal
weight and is narrow enough to clip on to all types of phase conductors
even in very tight and crowded cubicles. Mounting hardware is not required,
FASK is simple to secure in position using cable ties.
These CTs were the first to offer a hybrid integrator/buffer amplifier embedded in the clip assembly. This is digitally calibrated to provide a high linearity output characteristic. The absence of an iron core means that the FASK
displays no hysteresis, iron loss or turns ratio errors. The FASK cannot
magnetically saturate, there is no shock or damage hazard on open circuit.
The low voltage output signal can be routed up to 25m. to a meter, portable
instrument, energy logger or BMS outstation, without any loss of accuracy.
The FASK is a high accuracy CT particularly with the conductor centrally
positioned within the measurement coil. Its linearity provides a wide dynamic range, this enables accuracy to be maintained at the same level from
the maximum current rating to around a 5% of this rating.

242

www.mbs-stromwandler.de

MBS AG

FASK
Flexible Clip-On Current Transformers
Standard Product Availability
FASK production range, external power source 5 V, 9 V, 12 V, 24 V DC
Standard type
F302
F305
F4010
F6020
length [cm]
30
30
40
60
Current range Ip. [A]
200
500
1000
2000
Min. recommended Amps
10
20
20
40
Coil diameter closed [mm]
75
75
110
160
Rectangular coil [mm]
20 x 85
30 x 120
30 x 120
60 x 200
Maximum loops
1
1
1
2
Output Voltage
Full Scale output, Suffix
External power source

Integral Integrator
/05=500 mV AC
5 V DC reg

F7530
75
3000
50
200
60 x 250
3

In-line pod integrator


/1=1 V AC
/2=2 V AC
/3=3 V AC
5 V DC reg
9 V DC
12 V DC

F10030
100
3000
50
300
60 x 400
3/4
No Integrator
0.21 mV/A
without

Non-standard options
Any standard lengths (above) can be calibrated to any current range (in normal 100 A steps).
Output sensitivities selectable from 1003000 mV AC FSD for any CT (note required power source).

Construction characteristics:
Mouldings:
Winding/Coil former
Sleave material
Coil sheath diameter
Isolation test voltage
Bend radius
Operating temp.
Weight inc. 2 m lead

HIPS Plastics, IP40 Protection, Pollution degree PD2


Dual helical winding 330 turns/25mm on HPDF flexible former
PVC double insulation, wear indicator to IEC61010-1, Cat 3/600 V.
Colour Red. Special colours subject to minimum quantity order
11 mm, plug width 14 mm
3.5 kV, 6.5 kV peak 1,2/50 s, IEC61010-2-032 Type B transducer
30 mm minimum: number of loops see table above
-20 C to +85 C, Humidity 0 95 % non condensing
Fxx 30 120 g ---------- Fxx 100 250 g.

Measuring characteristics At 25 C. PF 0.71.0, 50/60 Hz between 10 % & 100 % of Ip


Current range
100 A 3000 A Standard range, 10 kA 100 kA extended range
Frequency range
Coil plus integrator: 25Hz-5kHz +/-2dB Max, typ.-1dB.
Accuracy
+/-3 % FS Ip. +/-1.5 % of reading FS Ip to >10 % Ip.
Phase shift
Max 1 , typical < 0.5 .
External Field
Full rejection adjacent bus > 1 x diameter away., conductor centralised
Output AC voltage
True rms value. Full scale value selectable, see table above
Output DC option
420 mA DC (2 wire), 01 V DC, 05 V DC (3 wire) for current/ kVA applications
External Power Source Integrator supply normally derived from host meter/instrument
Voltage
5 V DC regulated, 9, 12, 24 V DC unregulated.
Current
Typical 0.751.0 mA
Output leads
Red = + V supply, Yellow = Signal, Blue = 0 V Screen ground
Lead/cord length
2 m standard, extendable to 15 m

www.mbs-stromwandler.de

243

MBS AG

EMBSIN
Measuring transducers for electrical variables

MBSs measuring transducers of the type


EMBSIN transforms an input alternating voltage
and/or an input alternating current, received
as a standard signal from a current transformer,
or voltage transformer, or from the power
system, into a load imprinted output voltage.

The various EMBSIN units are arranged to collate all


measuring variables, which are necessary to monitor and
to control, the power supply and consumption, to display
the output signals, or to accept these into other units of
the measuring- and control technic.
Several units such as indicators, recorders or signal
processing systems can be connected to the output. The
transducers configuration asures a safe devision for all
functions for a galvanic separation between inputs and
outputs. The most important applications for the transducers are in the generation and distribution of energy,
in the manufacturing industry, and panel building enterprises.
The transducers have been developed upon an intirely
new housing technology concept and are available in
5 different sizes.
The housing material made of high quality polycarbonate
are free of silicon as well as halogen and, are flame
resistent. High quality screw terminals are provided for
the safe connections of inputs and outputs. Fitment onto
the base wall is made with a 35 mm DIN rail. All electrical
connections are made at the top of the units for safe
and easy access.

244

www.mbs-stromwandler.de

The transducers bear the CE symbol. This symbol


provides the highest level of protection for humans, the
machine, as well as the enviroment, and of course,
comply with all applicable safety regulations. MBSs
production of high current measuring transducers, made
of the finest quality enjoy a long tradition and a distinguished world wide reputation. The encapsuled
housing design, the carefully chosen material and the
construction principles, contribute that the measuring
transducers are protected against climatic conditions
(temperature and humidity), atmospheric conditions
(chemical processes, dust and salt), vibration and shocks,
interruptions (electrical or mechanical), HF interferences
(communications) as well as permanent or transient
interference voltages on all electrical connections.

MBS AG

Compact Safety Easy to use Accurate Better


Safety
EN 61010 also on the terminals!
690 V max. input voltage
housing material: Polycarbonate
fire resistance class: V-0 acc. to UL94
(self-extinguishing, halogen-free, silicon-free)
Easy to use
Units with two wide-and auxiliary power ranges
24 65 V AC/DC or 85 230 V AC/DC auxiliary
power, to be connected either on the top or on the bottom cos or linear recalibrating/ can be synchronized
without opening the unit and without AC calibrators!
mounting onto 35 mm DIN rail
operating instructions are included

Compact
height
height
depth
depth
width
width

75 mm, V-series
60 mm
105 mm, V-series
112 mm
45 mm, V-series
105 mm for power,
70 mm for frequency and phase as well as
U and I with wide-range auxiliary
power
35 mm two-wire feed 24 V DC or 230 V AC
35 mm for current and voltage without
auxiliary power supply
100 mm EMBSIN 391 PV

Accuracy
All units class 0.5
EMBSIN 241 FV class 0.2
EMBSIN 241 F class 0.2
EMBSIN 241 FD class 0.2
Better
Highest quality and safety at very competitive prices

assembly

easy to use
Ukal / Ucal Endwert /
Full-Scale

grob/coarse fein/fine
P231
P232

X174

grob/coarse fein/fine
+
P172
X173 P171

Nullpunkt / Zero

dismantling

Intermediate circuit calibration

www.mbs-stromwandler.de

245

MBS AG

EMBSIN 100 IV
Measuring transducers for AC current
without auxiliary voltage supply
housing for 35 mm DIN rail mounting
Features/benefits
measuring input: Sinus-shaped alternating current
(01 or 05 A) programmable at source
measuring output: Unipolar output signal
measuring principle: Rectifier mean value measurement process
without auxiliary voltage supply
economic consumption
Application
Measuring transducer for the proportional transformation of sinus-shaped
alternating currents into a load-independent DC signal. The output signal is
adjustable for analogue and digital units.

Technical data EMBSIN 100 IV


measuring input
rated frequency f N
rated input current IN
consumption
overload capacity
measuring output
load-independent
DC current I ON
burden voltage
burden resistance
residual ripple
of the output current
response time
accuracy
reference value
accuracy class
measuring range
reference conditions
ambient temperature
input signal
frequency

246

50/60 Hz
0...1 bis 0...7.5 A
) 2 VA
1.2 I N, constant
20 I N,1 sec.
0...5, 0...10 or
0...20 mA
) 15 V
RBmax = 15V k
ION [mA]

connection conditions
low voltage application
high voltage application
connection terminals
safety
protection class
nominal isolation voltage
test voltage

) 1 % p.p.
) 300 ms

electrocution protection

output end value


class 0.5
0...100 %

weight

15...30 C
0...100 %
45...65 Hz

www.mbs-stromwandler.de

feed by means of a low voltage


current transformer
feed by means of a high voltage
current transformer
) 4.0 mm2 solid wire
) 2 x 2.5 mm2 fine wire
II, (protection isolated,
DIN EN 61010)
300 V, rms, connection category III
500 V, rms, connection category II
3.7 kV, rms
in acc. with EN 61010-1:1990
IP 40, housing
(test wire, EN 60529)
IP 20, connection terminals
(test digit, EN 60529)
) 250 g

Order information see page 271

MBS AG

EMBSIN 100 I
Measuring transducers for AC current
without auxiliary voltage supply
with 2 measuring ranges
housing for 35 mm DIN rail mounting
Features/benefits
measuring input: Sinus-shaped alternating current
(01/5 A or 01.2/6 A, selectable at terminals), arithmetical mean value
measurement, effective value calibration
measuring output: Output signal unipolar
measuring principle: Rectifier mean value measurement process
without auxiliary voltage supply
economic consumption
Application
Measuring transducer for the transformation of sinus-shaped alternating current.
A load-independent DC signal which is proportional to the measurement
value serves as an output signal, and allows for display, recording, monitoring
and/or control functions. This measuring transducer fulfills the requirements
and regulations with regard to the electromagnetic compatibility (EMV) and
safety (IEC 1010 and EN 61010).

Technical data EMBSIN 100 I


measuring input
rated frequency f N
rated input current I N
consumption
overload capacity
measuring output
load-independent
DC current
burden voltage
voltage limit
by Rext = '
current limit
under overload
residual ripple
of the output current
response time

50/60 Hz
1/5 A or 1.2/6 A, selectable
) 2.5 VA
1.2 I N, constant,
20 I N, 1 sec.
0 5, 0 10 or
0 20 mA
) 15 V

accuracy
reference value
accuracy class
input
temperature influence
(-10 + 55 C)
safety
protection class
electrocution protection

) 30 V
) 34 mA
) 1 % p.p.
) 300 ms

contamination class
overvoltage category
nominal isolation
voltage (to earth)
weight

output end value


class 0.5
0 100 %
0.2 % / 10 K
II, (protection isolated, DIN EN 61010)
IP 40, housing
(test wire, EN 60529)
IP 20, connection terminals
(test digit, EN 60529)
2
III
250 V input
40 V output
270 g

Order information see page 271

www.mbs-stromwandler.de

247

MBS AG

EMBSIN 101 I
Measuring transducers for AC current
with auxiliary voltage supply
optional with measuring output 420 mA
and / or 2-wire technic
housing for 35 mm DIN rail mounting
Features/benefits
measuring input: Sinus-shaped alternating current, arithmetical mean value
measurement, effective value calibration
measuring output: Unipolar and live-zero output signals
measuring principle: Rectifier mean value measurement process
AC or DC auxiliary power supply
Application
Measuring transducer for the transformation of sinus-shaped alternating
current. A load-independent DC signal or imprinted DC voltage signal is
available, which stands proportionally to the measurement value of the input
volume. This measuring transducer fulfills the requirements and regulations
with regard to the electromagnetic compatibility (EMV) and safety (IEC 1010
and EN 61010).

measuring input
rated frequency f N
rated input current IN
consumption
overload capacity
measuring output
load-independent DC current

burden voltage
by 2-wire connection

imprinted DC voltage

load capacity
voltage limit by Rext = '
current limit
under overload
residual ripple of the
output current
response time

Technical data EMBSIN 101 I


auxiliary power
50/60 Hz
AC
0 0.8 to 0 1.2 A
or 0 4 to 0 6 A
) 5 mV IN
DC
2 IN, constant
0 2.5 mA to 0 20 mA
or live-zero
1 5 to 4 20 mA
) 15 V
standard range 4 20 mA,
external resistance Rext,
dependent of the auxiliary supply
H (12 32 V DC)
H [V] - 12 V
Rext max [k1] =
20 mA
0 5 to 0 10 V
or live-zero
1 5 to 2 10 V
max. 20 mA
) 40 V
< 30 mA by current output
approx. 20 mA by voltage output
) 1 % p.p.
< 300 ms

24, 110, 115, 120, 230 or 400 V,


15 %, 50 or 60 Hz;
Pv approx. 3 VA
24 V, - 15 / + 33 % or
24 V, - 50 / + 33 % by
2-wire feed and output
4 20 mA; Pv approx. 1.5 W
universal power supply ranges DC or AC 40 400 Hz
85 230 V
24 60 V
accuracy
reference value
output end value
accuracy class
class 0.5
safety
protection class
II, (protection isolated,
DIN EN 61010)
electrocution protection
IP 40, housing
(test wire, EN 60529),
IP 20 connection terminals
(test digit, EN 60529)
contamination class
2
overvoltage category
III
nominal isolation voltage
300 V, input
(to earth)
300 V, auxiliary power AC
50 V, auxiliary power 24 V DC
50 V, output
weight
195 g

Order information see page 272

248

www.mbs-stromwandler.de

MBS AG

EMBSIN 201 IEV


Measuring transducers for AC current
with auxiliary voltage supply
housing for 35 mm DIN rail mounting
Features/benefits
measuring input: Sinus-shaped alternating current (06 A)
measuring of the true rms value of alternating currents!
programmable measuring inputs and measuring outputs via RS232 or
RS485 interface (option)
low consumption
universal AC/DC auxiliary voltage supply or AC auxiliary voltage
Application
Measuring transducer for the proportional transformation of sinus-shaped
alternating currents into a load-independent DC current signal or AC voltage
signal. The analogue output signal is proportionable to the true rms value of
the measuring variables and can be used for regulating analogue and digital
units.

Technical data EMBSIN 201 IEV


measuring input
rated frequency fN
50/60 Hz
Rated input current IN
0...0.2 A to 0...6 A
own consumption
< 0,5 VA
operating temperature range -10 C ) ) +55 C
overload capacity
2 IN, constant
20 IN, 1 sec.
measuring output
load-independent DC current 0 ... 1 to 0 ... 20 mA or
live-zero
0.2 ... 1 to 4 ... 20 mA
burden voltage
) 15 V
imprinted DC voltage
0 ... 1 to 0 ... 10 V or
live-zero
0.2 ... 1 bis 2 ... 10 V
load capacity
max. 20 mA
output signal limit
current output
125 % IAN
voltage output
125 % UAN
residual ripple
of the output current
) 1 % p.p.
response time
< 300 ms
auxiliary power
universal power supply
DC or AC 40...70 Hz universal
voltage ranges
24 ... 300 V DC and 40 ... 276 V AC
AC power supply
45 ... 65 Hz
rated voltages:
57,74 V, 100 V, 230 V, 400 V, 500 V
power input
) 3 VA

accuracy
reference value
accuracy class
reference conditions
ambient temperature
input signal
frequency
protection
protection class

contamination class
test voltage
electrocution protection

interface
(optional)
connection terminals
weight

end value of input signal


class 0.5
15...30 C
0...100 % IN
45...65 Hz
II
300 V, rms, connection category III
500 V, rms, connection category II
2
3 kV, rms (acc. IEC 61010-1: 1990)
IP 40, housing
(test wire, EN 60529)
IP 20, connection terminals
(test digit, EN 60529)
RS232, MODBUS RTU
RS485, MODBUS RTU
) 4.0 mm2 single wire
) 2 x 2.5 mm2 Litze
approx. 300 g

Order information see page 273

RS232
Rx (21)
 (22)
Tx (23)
A (21)
C (22)
B (23)

9-pole plug (SUB-D)


Tx (3)
GND (5)
Rx (2)
RS485
DATA +
NC1)
DATA -

25-pole plug
Tx (2)
GND (7)
Rx (3)

1) -NC- do not connect !

www.mbs-stromwandler.de

249

MBS AG

EMBSIN 201 IE
Measuring transducers for AC current
with auxiliary voltage supply
effective value measuring
with 2 measuring ranges
housing for 35 mm DIN rail mounting
Features/benefits
measuring input: Sinus-shaped alternating current (01/5 A or 01.2/6 A,
selectable at terminals), or distorted, effective value measuring
measuring output: Unipolar and live-zero output signals
measuring principle: Logarithmetical process
universal power supply
Application
Measuring transducer for the transformation of sinus-shaped or distorded alternating currents. A load-independent DC current signal or imprinted DC voltage
signal is available, which is proportionally arranged to the rms input volume.
The measuring transducer fulfills the requirements and regulations with regard
to the electromagnetic compatibility (EMV) and safety (IEC 1010 or EN 61010).

Technical data EMBSIN 201 IE


measuring input
auxiliary power
rated frequency fN
50 / 60 or 400 Hz
universal power supply
DC or 40 400 Hz
rated input current IN
1/5 A or 1.2/6 A, selectable
AC / DC ranges
24 60 V or 85 230 V
consumption
) 1 VA
AC power supply
45 ... 65 Hz
operating temperature range -10 C ) ) +55 C
power input
) 1.5 W (3 VA)
overload capacity
1.2 IN, constant
accuracy
20 IN, 1 sec.
reference value
output end value
measuring output
accuracy class
class 0.5
load-independent DC current 0 1 to 0 20 mA or
peak value factor
32
live-zero 0.2 1 to 4 20 mA
warming-up time
) 5 min
burden voltage
) 15 V
safety
external resistance
protection class
II, (protection isolated, DIN EN 61010)
RBmax = 15V k1
IAN[mA]
electrocution protection
IP 40, housing
imprinted DC voltage
0 1 to 0 10 V or
(test wire, EN 60529)
live-zero 0.2 1 to 2 10 V
IP 20, connection terminals
load capacity
max. 2 mA
(test digit, EN 60529)
external resistance
contamination
class
2
[
]
U
V
RBmin = 2 AmA k1
overvoltage category
III
voltage limit
nominal isolation voltage
300 V, input
by Rext = '
) 25 V
(to earth)
230 V, auxiliary power
current limit
approx. 1.5 I AN
40 V, output
under overload
by current output,
weight
250 g
approx. 10 mA, by voltage output
residual ripple
) 0.5 % p.p. by response time 300 ms
of the output current
) 2 % p.p. bei response time 50 ms
response time
50 ms or 300 ms
Order information see page 275

250

www.mbs-stromwandler.de

MBS AG

EMBSIN 120 UV
Measuring transducers for AC current
without auxiliary voltage supply
housing for 35 mm DIN rail mounting
Features/benefits
measuring input: Sinus-shaped alternating voltage
(020 A or 0500 V)
measuring output: Unipolar output signal
measuring principle: Rectifier mean value measurement process
without auxiliary voltage supply
economic consumption
Application
Measuring transducer for the transformation of sinus-shaped alternating
currents into a load-independent DC current signal, which is arranged
proportionally to the input volume and is adaptable to be used for analogue
and digital units.

Technical data EMBSIN 201 IE


reference conditions
50/60 Hz
ambient temperature
0 ... 20 to 0 ... 500 V
input signal
linked voltage!
frequency
max. input voltage
connection conditions
to earth 250 V
low voltage application
consumption
) 2 VA
operating temperature range -10 C ) ) +55 C
relative average humidity
) 75 %
high voltage application
overload capacity
1.2 UN, constant
2.0 UN, 1 sec.
connection terminals
measuring output
load-independent
0 ... 5, 0 ... 10 or
safety
DC current ION
0 ... 20 mA
protection class
burden voltage
) 15 V
nominal isolation voltage
residual ripple
of the output current
) 1 % p.p.
test voltage
response time
) 300 ms
external resistance
electrocution protection
15V
RBmax = I [mA] k1
AN
measuring input
rated frequency fN
rated input voltage UN

accuracy
reference value
accuracy class

output end value


class 0.5

weight

15 ... 30 C
20 ... 100 % UN
45 ... 65 Hz
direct or via voltage transformer
with a nominal performance
P * 5 VA
via high voltage current
transformer with P * 5 VA
) 4,0 mm2 solid wire
) 2 x 2.5 mm2 Litze
II, (protection isolated, DIN EN 61010)
300 V, rms, connection category III
500 V, rms, connection category II
3.7 kV, rms
acc. to EN 61010-1: 1990
IP 50, housing
(test wire, EN 60529)
IP 20, connection terminals
(test digit, EN 60529)
250 g

Order information see page 276

www.mbs-stromwandler.de

251

MBS AG

EMBSIN 120 U
Measuring transducers for alternating voltage
without auxiliary voltage supply
housing for 35 mm DIN rail mounting
Features/benefits
measuring input: Sinus-shaped alternating voltage (020 A to 0500 V),
arithmetical mean value measurement, effective calibrated
measuring output: Unipolar output signal
measuring principle: Rectifire process
without auxiliary voltage supply
minimal wiring
Application
Measuring transducer for the transformation of sinus-shaped alternating voltage.
A load-independent DC current signal, which is proportionally to the measurement value, serves as an output signal, and allows for the display, recording,
monitoring and/or control function.
The measuring transducer fulfills the requirements and regulation with regard to
the electromagnetic compatibility (EMV) and safety (IEC 1010 or EN 61010).

Technical data EMBSIN 120 U


measuring input
rated frequency f N
rated input voltage UN

consumption
overload capacity

50/60 Hz
0 ... 20 to 0 ... 500 V
linked voltage!
max. input voltage
to earth 250 V
) 2 VA
1.2 UN, constant
2.0 UN, 1 sec.

measuring output
load-independent DC current I AN 0 ... 5, 0 ... 10 or 0 ... 20 mA
burden voltage
) 15 V
burden resistance
RBmax = 15V k1
IAN[mA]
voltage limit
Rext = '
current limit
under overload
residual ripple
of the output current
response time

252

) 54 V

accuracy
reference value
accuracy class
input signal
temperature influence
(-10 ... +55 C)
safety
protection class
electrocution protection

contamination class
nominal isolation voltage
weight

output end value


class 0.5
20 ... 100 %
0.2 % / 10 K
II, (protection isolated, DIN EN 61010)
IP 40, housing
(test wire, EN 60529)
IP 20, connection terminals
(test digit, EN 60529)
2
300 V, rms, connection categorie III
500 V, rmsm connection categorie II
260 g

) 1.7 IN
) 1 % p.p.
) 300 ms

www.mbs-stromwandler.de

Order information see page 276

MBS AG

EMBSIN 121 U
Measuring transducers for alternating voltage
with auxiliary voltage supply
optional measuring output 420 mA and/or
2-wire technic
housing for 35 mm DIN rail mounting
Features/benefits
measuring input: Sinus-shaped alternating voltage
arithmetical mean value measurement, effective calibrated
measuring output: Unipolar and live-zero output signal
measuring principle: Rectifier process
AC or DC auxiliary power
Application
Measuring transducer for the transformation of sinus-shaped alternating voltage.
A load-independent DC current signal or imprinted DC voltage signal is available which stands proportionally to the measurement value of the input
volume. The measuring transducer fulfills the requirements and regulation with
regard to the electromagnetic compatibility (EMV) and safety (IEC 1010 or
EN 61010).
Technical data EMBSIN 201 IE
measuring input
rated frequency
rated input voltage UN

consumption by
UN ) 150 V
150 V < UN ) 400 V
400 V < UN ) 600 V
overload capacity

50/60 Hz
0 ... 50 to 0... 600 V
linked voltage!
max. 300 V nominal value of the
mains to earth (operating
voltage acc. to EN 61010)
< UN 50 A
< UN 20 A
< UN 5 A
1.2 UN, constant
2.0 UN, 1 sec.

measuring output
load-independent DC current 0 ... 2.5 mA to 0 ... 20 mA or
live-zero 1 ... 5 to 4 ... 20 mA
burden voltage
) 15 V
by 2-wire connection
standard range 4 ... 20 mA
external resistance R ext,
dependent of the auxiliary power
H (12 ... 32 V DC)
H[V]12 V
Rextmax.[k1] =
20 mA
imprinted DC voltage
load capacity
voltage limit
by Rext = '
current limit
under overload
residual ripple
of the output current
response time

0 ... 5 bis 0 ... 10 V or


live-zero 1 ... 5 to 2 ... 10 V
max . 20 mA

auxiliary power
AC

24, 110, 115, 120, 230 or


400 V, 15 %, 50/60 Hz; approx. 3 VA
DC
24 V, 15/+ 33 % or
24 V, 50/+ 33 % by
2-wire feed and output
4 ... 20 mA; approx. 1.5 W
universal power supply ranges DC or AC 40 400 Hz
85 230 V
24 60 V
accuracy
reference value
output end value
accuracy class
class 0.5 (UN ) 500 V)
class 1 (UN > 500 V)
safety
protection class
II, (protection isolated, DIN EN 61010)
electrocution protection I P 40, housing
(test wire, EN 60529)
IP 20, connection terminals
(test digit, EN 60529)
contamination class
2
overvoltage category
III
nominal isolation voltage 300 V, input
(to earth)
300 V, auxiliary power AC
50 V, auxiliary power 24 V DC
50 V, output
weight
280 g

) 40 V
< 30 mA by current output
approx. 20 mA by voltage output
) 1 % p.p.
< 300 ms

www.mbs-stromwandler.de

253

MBS AG

EMBSIN 221 UEV


Measuring transducers for alternating voltage
with auxiliary voltage supply
housing for 35 mm DIN rail mounting
Features/benefits
measuring input: Sinus-shaped alternating voltage (050 to 0500 V)
measuring output: Unipolar and live-zero output signal
measuring principle: Digital, true rms measuring
with auxiliary voltage supply via AC/DC supply or AC supply
economical consumption
programmable measuring input and output via optional serial interface
RS 232/ RS485
Application
Measuring transducer for the transformation of sinus-shaped or distorted alternating voltage into a load-independent
DC current- or DC voltage signal. The analogue output signal is proportionally to the true rms value of the measuring
variables and can be used for regulating analogue and digital units. The input and output volumes can be configured
via an interface RS232 or RS485 by means of a parametical software MBSET. Before setting the parameter, the output ranges have to be tuned via jumpers. There is a choice of 3 output signals.

Technical data EMBSIN 221 UEV


measuring input
rated frequency
rated input voltage UN
consumption
overload capacity

50/60 Hz
0 ... 50 to 0 ... 500 V
< 0.5 VA
1.2 UN, constant
2.0 UN, 1 sec.

measuring output
load-independent DC current ION 0 ... 1 to 0 ... 20 mA or
live-zero
0.2 ... 15 to 4 ... 20 mA
burden resistance
RBmax. = 15 V k1
ION[mA]
burden voltage
imprinted DC voltage UON

burden resistance
voltage
load capacity
output signalling limit
current output
voltage output
residual ripple
of the output current
response time

)15 V
0 ... 1 to 0 ... 10 V or
live-zero
0.2 ... 1 to 2 ... 10 V
UON[V]
RBmin. =
20 mA
max. 20 mA
125 % IAN
125 % UAN
) 1 % p.p.
) 300 ms

auxiliary power
universal power supply
voltage ranges
AC power supply
rated voltages:
power input
accuracy
reference value
accuracy class
reference conditions
ambient temperature
input signal
frequency
safety
protection class

contamination class
test voltage
electrocution protection I

interface
(optional)
connection terminals

Order information see page 273


weight

DC or AC 4070 Hz universal
24 ... 300 V DC and 40 ... 276 V AC
45 ... 65 Hz
57,74 V, 100 V, 230 V, 400 V, 500 V
) 3 VA
output end value
class 0.5
15 ... 30 C
0 ... 100 % IN
45...65 Hz
II
300 V, rms, connection category III
500 V, rms, connection category II
2
3 kV, rms,
(acc. to IEC 61010-1:1990)
P 40, housing
(test wire, EN 60529)
IP 20, connection terminals
(test digit, EN 60529)
RS232, MODBUS RTU
RS485, MODBUS RTU
) 4.0 mm2 single wire
) 2 x 2.5 mm2 Litze
approx. 300 g
RS232

Rx (21)
 (22)
Tx (23)

254

www.mbs-stromwandler.de

A (21)
C (22)
B (23)

9-pole plug (SUB-D)


Tx (3)
GND (5)
Rx (2)
RS485
DATA +
NC1)
DATA -

1) -NC- do not connect !

25-pole plug
Tx (2)
GND (7)
Rx (3)

MBS AG

EMBSIN 221 UE
Measuring transducers for alternating voltage
with auxiliary voltage supply
effective value measuring
housing for 35 mm DIN rail mounting
Features/benefits
measuring input: Alternating voltage (020 to 0690 V)
sinus-shaped or distorted ,effective value measuring
measuring output: Unipolar and live-zero output signals
measuring principle: Logarithmetical process
AC/DC auxiliary power by means of universal power supply
Application
Measuring transducer for the transformation of sinus-shaped or distorded alternating voltages. A load-independent DC current signal or imprinted DC voltage
signal is available, which is proportionally arranged to the rms measurement
value of the input volume.
The measuring transducer fulfills the requirements and regulations with regard
to the electromagnetic compatibility (EMV) and safety (IEC 1010 or EN 61010).
Technical data EMBSIN 221 UE
measuring input
rated frequency fN
rated input voltage UN

consumption
overload capacity

50/60 Hz or 400 Hz
0 ... 20 to 0 ... 690 V
(max. 264 V by auxiliary power
from voltage measuring input)
max. input voltage
to earth 400 V
) 1 VA
1.2 UN, constant,
2.0 UN, 1 sec.

measuring output
load-independent DC current 0 ... 1 to 0 ... 20 mA or
live-zero 0.2 ... 1 to 4 ... 20 mA
burden voltage
) 15 V
imprinted DC voltage
0 ... 1 to 0 ... 10 V or
live-zero 0.2 ... 1 to 2 ... 10 V
load capacity
max. 2 mA
voltage limit
bei Rext = '
) 25 V
current limit
approx. 1.5 IAN
under overload
by current output
approx. 10 mA
by voltage output
residual ripple
) 0.5 % p.p. by response time 300 ms
of the output current
) 2 % p.p. by response time 50 ms
response time
50 ms or 300 ms

auxiliary power
universal power supply
AC/DC ranges

power input
accuracy
reference value
accuracy class
peak value factor
warming-up time
safety
protection class
electrocution protection

contamination class
overvoltage category
nominal isolation voltage
(to earth)
weight

DC or AC (40 ... 400 Hz)


85 ... 230 V or 24 ... 60 V
DC - 15 % / + 33 %
AC 15 %
) 1.5 W (3 VA)
output end value
class 0.5
32
) 5 min.
II, (protection isolated,
DIN EN 61010)
IP 40, housing
(test wire, EN 60529)
IP 20, connection terminals
(test digit, EN 60529)
2
III
400 V, input
230 V, auxiliary power
40 V, output
300 g

Order information see page 275

www.mbs-stromwandler.de

255

MBS AG

EMBSIN 241 FV
Measuring transducers for frequency
with auxiliary voltage supply
housing for 35 mm DIN rail mounting
Features/benefits
Measuring transducer for measuring the frequency of sinus-shaped
alternating voltages
programmable measuring inputs and outputs by means of optional available
serial interface RS232 or RS485
low consumption
accuracy class 0.2
digital measuring process
auxiliary voltage supply by means of universal AC/DC or AC supplies.
Application
The programmable measuring transducer type EMBSN 241 FV is being used for converting the frequency of sinusshaped AC alternating voltage signals into a load-independent output volume. The analogue output signals (current or
voltage) are arranged proportionally to the frequency of the voltage input and can be used for regulating analogue or
digital units. The input volumes and output volumes can be configured via the available interface RS232 or RS484 with
MBSET parametic sofware.

Technical data EMBSIN 241 FV


measuring input
measuring range
input voltage (UI)
consumption
overload capacity
(acc. to IEC 60688, 1992)
measuring output
load-independent DC current
burden resistance
current output
burden voltage
imprinted DC voltage
burden resistance
voltage output
output signalling limit
current output
voltage output
residual ripple
of the output current
response time

40 ... 70 Hz
3 ... 500 V
< 0.5 VA
1.2 UN, constant
2.0 UN, 1 sec.
0 ... 1 mA to 0 ... 5 mA or
0 ... 5 mA to 0 ... 20 mA
15[ V ]
RBmax =
k1
ION [ mA]
) 15 V
0 ... 1 V or 0 ... 10 V
RBmin =

UON [V]
k1
20[mA]

125 % IAN
125 % UAN
) 1 % p.p.
) 300 ms

auxiliary power
universal power supply
voltage ranges
AC power supply
nominal voltages:
power input
accuracy
reference value
accuracy class
reference conditions
ambient temperature
input signal
frequency
safety
protection class

contamination class
test voltage
electrocution protection

Order information see page 277


interface
(optional)
connection terminals
weight

DC or AC 40...70 Hz universal
24 ... 300 V DC and 40 ... 276 V AC
45 ... 65 Hz
57,74 V, 100 V, 230 V, 400 V, 500 V
) 3 VA
input end value
class 0.2
15 ... 30 C
0 ... 100 % IN
45 ... 65 Hz
II
300 V, rms, connection category III
500 V, rms, connection category II
2
3 kV, rms
(acc. to IEC 61010-1:1990)
IP 40, housing
(test wire, EN 60529)
IP 20, connection terminals
(test digit, EN 60529)
RS232, MODBUS RTU
RS485, MODBUS RTU
) 4.0 mm2 single wire
) 2 x 2.5 mm2 Litze
approx. 300 g
RS232

Rx (21)
 (22)
Tx (23)

256

www.mbs-stromwandler.de

A (21)
C (22)
B (23)

9-pole plug (SUB-D)


Tx (3)
GND (5)
Rx (2)
RS485
DATA +
NC1)
DATA -

1) -NC- do not connect !

25-pole plug
Tx (2)
GND (7)
Rx (3)

MBS AG

EMBSIN 241 F
Measuring transducers for frequency
with auxiliary voltage supply
housing for 35 mm DIN rail mounting
Features/benefits
measuring input: sinus-shaped, rectangular shaped or distorted input voltage
(10 to 690 V, 10 Hz to 1.5 kHz) with dominant basic wave
measuring output: Unipolar, bipolar or live-zero output signal
measuring principle: Digital constant period measuring
AC/DC auxiliary power by means of universal power supply
Application
Measuring transducer for frequency
A load-independent DC signal or an imprinted DC voltage signal is available
which stands proportional to the frequency of the input volume. The measuring
transducer fulfills the requirements and regulations with regard to the electromagnetic compatibility of (EMV) and safety (IEC 1010 or EN 61010).

Technical data EMBSIN 241 F


measuring input
rated frequency

min. range
rated input voltage UN
consumption
overload capacity

wave shape
measuring output
load-independent DC current

bipolar
burden voltage
imprinted DC voltage
unipolar
bipolar
load capacity
voltage limit
by Rext = '
current limit
under overload
residual ripple
of the output current
nominal value response time
other ranges

selectable between
fu = 10 Hz and
fo = 1500 Hz
fu /(fo-fu) < 50
10 ... 230 V or 230 ... 690 V
< UN 1.5 mA
1.2 UN, constant
2.0 UN, 1 sec.
(max. 264 V by auxiliary power
from voltage measuring input)
any, only basic wave
will be considered

auxiliary power
universal power supply

AC / DC
or AC-auxiliary power from
voltage measuring input
accuracy
reference value
accuracy class
safety
protection class
electrocution protection

0 ... 1 to 0 ... 20 mA or
unipolar live-zero
1 ... 5 to 4 ... 20 mA
1 to 20 mA
) +15 V, resp. -12 V
0 ... 1 to 0 ... 10 V or
live-zero 0.2 ... 1 to 2 ... 10 V
1 to 10 V
max. 4 mA

contamination class
overvoltage category
nominal isolation voltage
(to earth)
weight

DC or AC (40 ... 400 Hz)


DC -15 % / + 33 % 1.5 W
AC 15 % 3 VA
24 ... 60 V or 85 ... 230 V
24 ... 60 V or 85 ... 230 V,
(40 Hz ) f ) 400 Hz) 15 %
output range
class 0.2
II, (protection isolated,
DIN EN 61010)
IP 40, housing
(test wire, EN 60529)
IP 20, connection terminals
(test digit, EN 60529)
2
III
230 or 400 V, input
230 V auxiliary power
40 V output
230 g

) 25 V
approx. 1.3 IAN by current output
approx. 30 mA by voltage output
< 0.5 % p.p.
4 periods of the measuring
frequency
2, 8 or 16 periods
of the measuring frequency

Order information see page 278

www.mbs-stromwandler.de

257

MBS AG

EMBSIN 241 FD
Measuring transducers for
frequency difference
housing for 35 mm DIN rail mounting
Features/benefits
measuring inputs: Sinus-shaped, rectangular or distorted input voltage
(10 to 690 V, 6f = 1 % fs to 80 % fs, fs and fG * 10 Hz to ) 1.5 kHz)
with dominant basic wave
measuring output: Unipolar, bipolar, or live-zero output signal
measuring principle: Digital, constant period measuring
AC/DC auxiliary power by means of universal power supply
Application
Measuring transducers for monotoring the frequency difference between two
synchronized supplies. A load-independent DC signal or an imprinted DC voltage signal is available as an output signal, which stands proportionally to the
measuring value. The measuring transducer fulfills the requirements and regulations with regard to the electromagnetic compatibility (EMV) and safety (IEC
1010 or EN 61010).

Technical data EMBSIN 241 FD


measuring input
measuring range

6f = 1 % fS to 80 % fS;
fS and fG * 10 Hz to ) 1.5 kHz
generator or bus bar
10 ... 230 V or 230 .. .690 V
Three-phase system!
Input voltage = linked voltage
(max. 230 V by auxiliary power
from voltage measuring input)
< UN 1.5 mA per measuring
input
1.2 UN, constant
2.0 UN, 1 sec.
(max. 264 V by auxiliary power
from voltage measuring input)
any, only basic wave
will be considered

input voltage UN

consumption
overload capacity

wave shape
Measuring output
load-independent DC current
unipolar
bipolar
burden voltage
imprinted DC voltage
unipolar
bipolar
load capacity
voltage limit by Rext = '
current limit
under overload
residual ripple
of the output current

258

nominal value of the


response time
other ranges
auxiliary power
universal power supply
AC/DC ranges
or auxiliary power from
voltage measuring input
power input
accuracy
reference value
accuracy class
safety
protection class
electrocution protection

0 ... 1 to 0 ... 20 mA or
live-zero 1 ... 5 to 4 ... 20 mA
(120) mA
) 15 V or * - 12 V
0 ... 1 to 0 ... 10 V or
live-zero 0.2 ... 1 to 2 ... 10 V
(110) V
max. 4 mA
) 25 V
approx. 1.3 IAN by current output
approx. 30 mA at voltage output
< 0.5 % p.p.

www.mbs-stromwandler.de

contamination class
overvoltage category
nominal isolation voltage
(to earth)
weight

4 periods of the
measuring frequency
2, 8 or 16 periods
of the measuring frequency
DC or AC (40 ... 400 Hz)
85 ... 230 V or 24 ... 60 V
24 ... 60 V to 85 ... 230 V
at 40 Hz ) f ) 400 Hz
approx. 2 W or 4 VA
nominal value output
class 0.2
II, (protection isolated,
DIN EN 61010)
IP 40, housing
(test wire, EN 60529)
IP 20, connection terminals
(test digit, EN 60529)
2
III
230 V or 400 V, input
230 V, auxiliary power
40 V, output
270 g

Order information see page 278

MBS AG

EMBSIN 271 G
Measuring transducers for phase angle
housing for 35 mm DIN rail mounting
Features/benefits
measuring input: Sinus-shaped, rectangular or distorted input volumes
with dominant basic wave
input signal: 1 A or 5 A, 10 V to 690 V
measuring range: Phase angle -180 el ) ) + 180 el
measuring output: Unipolar, bipolar or live-zero output signal
measuring principle: Monotoring of the zero currents
AC/DC auxiliary power by means of universal power supply
Application
Measuring transducers for measuring of phase angle between current and voltage of a sinus-shaped single-phase
supply or a symetric load of a three-phase supply. A load-independent DC current signal or imprinted DC voltage
signal is available, which is proportionally arranged to the phase angle between the measuring signal of current and
voltage. The measuring transducer fulfills the requirements and regulations with regard to the electromagnetic compatibility (EMV) and safety (IEC 1010 or EN 61010).

Technical data EMBSIN 271 G


measuring input
measuring range
phase angle
nominal frequency fN
input voltage UN

rated input current IN


consumption
overload capacity

measuring output
load-independent DC current
unipolar
bipolar
burden voltage
imprinted DC voltage
unipolar
bipolar
load capacity
voltage limit by Rext = '
current limit
under overload

- 175el ... 0 ... + 175el


min. measuring range * 20el
16 2/3 ... 400 Hz
10 ... 690 V (max. 230 V
by auxiliary power
from voltage measuring input)
1 A or 5 A
< 0.1 VA current path
UN 1.5 mA voltage path
1.2 I N, constant
1.2 UN, constant
20 IN, 1 sec.
2.0 UN, 1 sec.
(max. 264 V by auxiliary power
from voltage measuring input)
0 ... 1 to 0 ... 20 mA or
live-zero 1 ... 5 to 4 ... 20 mA
(1 20) mA
) + 15 V or * - 12 V
0 ... 1 to 0 ... 10 V or
live-zero 0.2 ... 1 to 2 ... 10 V
(1 10) V
max. 4 mA
) 25 V
approx. 1.3 IAN
by current output
approx. 30 mA by voltage output

residual ripple
of the output current
nominal value of the
response time
other ranges
auxiliary power
universal power supply
AC/DC ranges
or auxiliary power from
voltage measuring input
power input
accuracy
reference value
accuracy class
safety
protection class
electrocution protection

contamination class
overvoltage category
nominal isolation voltage
(to earth)
weight

< 0.5 % p.p.


4 periods of the
measuring frequency
2, 8 or 16 periods of
the measuring frequency
DC or AC (40 ... 400 Hz)
85 ... 230 V or 24 ... 60 V
85 ... 230 V or 24 ... 60 V
) 2 W (4 VA)
6 = 90
class 0.5
II, (protection isolated,
DIN EN 61010)
IP 40, housing
(test wire, EN 60529)
IP 20, connection terminals
(test digit, EN 60529)
2
II
230 or 400 V, input
230 V, auxiliary power
40 V, output
240 g

Order information see page 279

www.mbs-stromwandler.de

259

MBS AG

EMBSIN 271 GD
Measuring transducers for phase angle
difference
housing for 35 mm DIN rail mounting
Features/benefits
measuring input: Sinus-shaped, rectangular or distorted rated input voltages
10 to 690 V, 10 el ) ) 180 el) with dominant basic wave
measuring output: Unipolar, bipolar or live-zero output signal
measuring principle: Monitoring of the zero currents
AC/DC auxiliary power by means of universal power supply
Application
Measuring transducers for monitoring of the phase angle difference between
two synchronized supplies. A load-independent DC current signal or imprinted
DC voltage signal is available which is proportionally arranged to the measuring
value. The measuring transducer fulfills the requirements and regulations with
regard to the electromagnetic compatibility (EMV) and safety (IEC 1010 or
EN 61010).

Technical data EMBSIN 271 GD


measuring input
measuring range
rated frequency f N
input voltages UN

- 120 ... 0 ... 120 el


50 or 60 Hz
generator and bus bar
10 ... 230 V or 230 ... 690 V
Three-phase system!
UN = linked voltage
(max. 230 V by auxiliary power
from voltage measuring input)
< UN 1.5 mA per measuring input
1.2 UN, constant
2.0 UN, 1 sec.
(max. 264 V by auxiliary power
from voltage measuring input)

consumption
overload capacity

measuring output
load-independent DC current
unipolar
bipolar
burden voltage
imprinted DC voltage
unipolar
bipolar
load capacity
voltage limit by R ext = '
current limit
under overload
residual ripple
of the output current
nominal value of the
response time
other ranges

260

0 ... 1 to 0 ... 20 mA or
live-zero 1 ... 5 to 4 ... 20 mA
(1 20) mA
) +15 V, resp. * -12 V
0 ... 1 to 0 ... 10 V or
live-zero 0.2 ... 1 to 2 ... 10 V
(1 10) V
max. 4 mA
25 V
approx. 1.3 IAN by current output
approx. 30 mA by voltage output
< 0.5 % p.p.
4 periods of the
measuring frequency
2, 8 or 16 periods of
the measuring frequency

www.mbs-stromwandler.de

auxiliary power
universal power supply

AC/DC ranges
power input
accuracy
reference value
accuracy class
safety
protection class
electrocution protection

contamination class
overvoltage category
nominal isolation voltage
(to earth)
weight

DC or AC (40 ... 400 Hz)


DC (- 15 ... + 33 %)
AC ( 15 %; 40 ... 400 Hz)
85 ... 230 V or 24 ... 60 V
) 2 W (4 VA)
6 = 90
class 0.5
II, (protection isolated,
DIN EN 61010)
IP 40, housing
(test wire, EN 60529)
IP 20, connection terminals
(test digit, EN 60529)
2
III
230 V or 400 V, input
230 V, auxiliary power
40 V, output
270 g

Order information see page 281

MBS AG

EMBSIN 281 G
Measuring transducers for power factor
housing for 35 mm DIN rail mounting
Features/benefits
measuring input: Sinus-shaped, rectangular or distorted rated input signal
with dominant basic wave
input signals: 1 A or 5 A, 10 V to 690 V
power factor cos 0.5 cap.-1-0.5 ind.
measuring output: Unipolar, bipolar or live-zero output signal
measuring principle: Monitoring the distance of zero currents
AC/DC auxiliary power by means of universal power supply
Application
Measuring transducers for the measuring of the power factor between current and voltage of a sinus-shaped singlephase supply or a symetric load of a three-phase supply. A load-independent DC current signal or imprinted DC
voltage signal is available which is proportionally arranged to the power factor between the measuring volumes of
current and volt. The measuring transducer fulfills the requirements and regulations with regard to the electromagnetic
compatibility (EMV) and safety (IEC 1010 or EN 61010).

Technical data EMBSIN 281 G


measuring input
power factor cos
rated frequency f N
input voltage UN

rated input current I N


consumption
overload capacity

measuring output
load-independent DC current
unipolar
bipolar
burden voltage
imprinted DC voltage
unipolar
bipolar
load capacity
voltage limit by Rext = '
current limit
under overload
residual ripple
of the output current
nominal value of the
response time
other ranges

0.5-cap-1-ind-0.5
16 2/3 ... 400 Hz
10 ... 690 V (max. 230 V
by auxiliary power
from voltage measuring input)
1 A or 5 A
< 0.1 VA current path
UN 1.5 mA voltage path
1.2 IN, constant
1.2 UN, constant
20 IN, 1 sec.
2.0 UN, 1 sec.
(max. 264 V by auxiliary power
from voltage measuring input)
0 ... 1 to 0 ... 20 mA or
live-zero 1 ... 5 to 4 ... 20 mA
(1 20) mA
) +15 V resp. * -12 V
0 ... 1 to 0 ... 10 V or
live-zero 0.2 ... 1 to 2 ... 10 V
(1 10) V
max. 4 mA
) 25 V
approx. 1.3 IAN by current output
approx. 30 mA by voltage output
< 0.5 % p.p.
4 periods of
the measuring frequency
2, 8 or 16 periods of
the measuring frequency

auxiliary power
universal power supply
AC/DC ranges
or auxiliary power
from voltage input
power input
accuracy
reference value
accuracy class
safety
protection class
electrocution protection

contamination class
overvoltage category
nominal isolation voltage
(to earth)
weight

DC or AC (40 ... 400 Hz)


85 ... 230 V or 24 ... 60 V
85 ... 230 V or 24 ... 60 V
) 2 W (4 VA)
6 cos = 0.5
class 0.5
II, (protection isolated,
DIN EN 61010)
IP 40, housing
(test wire, EN 60529)
IP 20, connection terminals
(test digit, EN 60529)
2
III
230 V or 400 V, input
230 V, auxiliary power
40 V, output
260 g

Order information see page 279

www.mbs-stromwandler.de

261

MBS AG

EMBSIN 351 P
Measuring transducers for active power
housing for 35 mm DIN rail mounting
Features/benefits
measuring input: Sinus-shaped nominal input currents (1 A or 5 A) and
nominal input voltages (100 V to 690 V)
measuring output: Unipolar, bipolar or live-zero output signal
measuring principle: Impulse width modulation (TDM-process),
TDM = time division multiplication
AC/DC auxiliary power by means of universal power supply
Application
Measuring transducer for the transformation of the active power of a singlephase alternative AC current or three-phase current supply of equal or unequal
phase load.
A load-independent DC current signal or imprinted DC voltage signal is available, which is proportionally arranged to the measuring value of the active
power.
The measuring transducers fulfill the requirements and regulations, with regard
to the electromagnetic compatibility (EMV) and safety (IEC 1010 or EN 61010).

Technical data EMBSIN 351 P


measuring input
rated frequency f N
rated input voltage U N

rated input current I N


calibration factor c
permissable
measuring range
consumption
overload capacity

measuring output
load-independent DC current
unipolar
bipolar
burden voltage
imprinted DC voltage
unipolar
bipolar
load capacity
voltage limit by Rext = '
current limit
under overload
residual ripple
of the output current
response time

262

50 Hz or 60 Hz
3-phase system
UN = linked voltage
10 ... 690 V (max. 230 V by
auxiliary power from
voltage measuring input)
1 A or 5 A
0.75 to 1.3 by active power
by active power
* 0.75 to 1.3 33 U N I N
< 0.1 VA per current path
UN 1 mA per voltage path
1.2 IN, constant; 20 IN, 1 sec.
1.2 UN, constant; 2.0 UN, 1 sec.
(max. 264 V by auxiliary power
from voltage measuring input)
0 ... 2.5 to 0 ... 20 mA or
live-zero 1 ... 5 to 4 ... 20 mA
(2.5 20) mA
15 V
0 ... 10 V or
live-zero 2 ... 10 V
10 V
max. 4 mA
) 40 V
approx. 1.3 IAN by current output
approx. 30 mA by voltage output
< 2 % p.p.
< 300 ms

www.mbs-stromwandler.de

auxiliary power
universal power supply
AC/DC
or auxiliary power from
voltage measuring input
power input
accuracy
reference value
accuracy class
safety
protection class
electrocution protection

contamination class
overvoltage category
nominal isolation voltage
(to earth)
weight

DC or AC (40 ... 400 Hz)


85 ... 230 V or 24 ... 60 V
* 85 V to ) 230 V AC
) 2.5 W (4.5 VA)
output end value
class 0.5
II, (protection isolated,
DIN EN 61010)
IP 40, housing
(test wire, EN 60529)
IP 20, connection terminals
(test digit, EN 60529)
2
III
400 V, input
230 V, auxiliary power
40 V, output
700 g

Order information see page 282

MBS AG

EMBSIN 361 Q
Measuring transducers for re-active power
housing for 35 mm DIN rail mounting
Features/benefits
measuring input: Sinus-shaped nominal input currents (1 A or 5 A) and nominal
input voltages (100 V to 690 V)
measuring output: Unipolar, bipolar or live-zero output signal
measuring principle: Impulse width modulation (TDM-process),
TDM = time dIvision multiplication
AC/DC auxiliary power by means of universal power supply
Application
Measuring transducer for the transformation of the re-active power of a singlephase alternative AC current or three-phase current supply of equal or unequal
phase load.
A load-independent DC current signal or imprinted DC voltage signal is available, which is proportionally arranged to the measuring value of the re-active
power.
The measuring transducers fulfill the requirements and regulations, with regard
to the electromagnetic compatibility (EMV) and safety (IEC 1010 or EN 61010).

Technical data EMBSIN 361 Q


measuring input
rated frequency f N
rated input voltage UN

rated input current I N


calibration factor c
permissable measuring
range end values
consumption
overload capacity

measuring output
load-independent DC current
unipolar
bipolar
burden voltage
imprinted DC voltage
unipolar
bipolar
load capacity
voltage limit by Rext = '
current limit
under overload
residual ripple
of the output current
response time

50 Hz
Three-phase system
UN = linked voltage
10 ... 690 V (max. 230 V by
auxiliary power from
voltage measuring input)
1 A or 5 A
0.5 to 1.0 by re-active power
by re-active power
* 0.5 to 1.0 3 3 UN I N
< 0.1 VA per current path
UN 1 mA per voltage path
1.2 IN, constant; 20 IN, 1 sec.
1.2 UN, constant; 2.0 UN, 1 sec.
(max. 264 V by auxiliary power
from voltage measuring input)
0 ... 2.5 to 0 ... 20 mA or
live-zero 1 ... 5 to 4 ... 20 mA
(2.5 20) mA
15 V
0 ... 10 V bzw.
live-zero 2 ... 10 V
10 V
max. 4 mA
) 40 V
approx. 1.3 IAN by current output
approx. 30 mA by voltage output
< 2 % p.p.
< 300 ms

auxiliary power
universal power supply
AC/DC
or auxiliary power from
voltage measuring input
power input
accuracy
reference value
accuracy class
safety
protection class
electrocution protection

contamination class
overvoltage category
nominal isolation voltage
(to earth)
weight

DC or AC (40 ... 400 Hz)


85 ... 230 V or 24 ... 60 V
* 85 V to ) 230 V AC
) 2.5 W (4.5 VA)
output end value
class 0.5
II, (protection isolated,
DIN EN 61010)
IP 40, housing
(test wire, EN 60529)
IP 20, connection terminals
(test digit, EN 60529)
2
III
400 V, input
230 V, auxiliary power
40 V, output
700 g

Order information see page 282

www.mbs-stromwandler.de

263

MBS AG

EMBSIN 301
Programmable measuring transducers for
alternating current
Features/benefits
auxiliary power supply 230 V AC or 24 V DC.
two remote controlable measuring ranges from 20600 A AC
two simultaneously available analogue measuring outputs
programmable output characteristic curves
current circuit control by means of programmable control circuits
information of the actual operation conditions through two open collector
transistors in connection with simultaneous signalling of colored light
emittance diods

Basic circuit diagram

Dimensions:
Depth x length x height:
(87.5 x 70 x 114 mm)

Application
Programmable measuring transducer for monitoring sinus-shaped as well as
distorted AC currents in the rated current range of 20 600 A. Inductive,
galvanically separated measuring value collection is secured by means of an
integrated current transformer.
As an output signal, proportionally arranged to the measurement value (rms) a
DC current signal and an imprinted DC voltage signal is available. By means of
an integrated interface RS232 the following additional power features can be
realized:
adjustment of the output characteristics of the analogue outputs
0(4) 20 mA or 0(2) 10 V
nominal current control by means of two programmable control circuits
optimal signallizing of the actual value of the measuring volumes in realiance
to the tuned control circuits by means of three-coloured light emittance diods
energizing of the switch operations (i.e. IMin / IMax-monitoring) by means of two
open collector transistors, designated to the tuned switch circuits
measuring value continuous monitoring of measuring values and data saving,
when interacting with external computers.
Technical data EMBSIN 301

measuring input
measuring variable
measuring range
rated frequency f N
consumption
overload capacity

sinus-shaped or distorted
alternating current
20 ... 600 A AC
50 Hz
< 0.5 VA
1.5 IN, constant
8.0 IN, 40 sec.

measuring output
current output
load-independent DC current 020 mA or live-zero 420 mA,
programmable by means of software
max. burden voltage
) 15 V DC
max. burden resistance
RB ) 500 1
residual ripple of
the output current
< 0.5 % p.p.
current limit
under overload
) 30 mA
voltage output
imprinted DC voltage
010 V or live-zero 210 V,
unipolar
programmable by means of software
min. burden resistance
) 10 k1
voltage limit by R ext = '
) 15 V
response time of
the output signal
50 ms

accuracy
reference value
accuracy class
working range
warming-up time
auxiliary power
AC
DC (optional)
operating conditions
field of operation
working temperature
storage temperature
energizing
2 open-collector
transistor outputs

UCEmax
ICEmax
interface
series
standard

nominal output value


class 0.5
(0.5 % from output end value)
1 ... 120 % IN
) 5 min
230 V 10 %
24 V 15 %
indoors without humidity
- 5 C ) + 45 C
- 40 C ) + 70 C
for load current dependent
monitoring of relay controls;
programmable control circuits
via units software
50 V
35 mA
RS 232, connection via 9-pole
SUB-D-plug
IEC 60688
IEC 61000

Order information see page 283

264

www.mbs-stromwandler.de

MBS AG

EMBSIN 391 PV
Programmable measuring transducers
for all electrical parameters
with auxiliary voltage supply
housing for 35 mm DIN rail mounting
Features/benefits
multifunctional measuring transducer for the simultaneous distribution of 3
parameters of the electrical system
monotoring of up to 50 different parameters (V, A, kW, kVA, )
programmable measuring inputs and measuring outputs
low power consumption
auxiliary power supply by means of universal AC/DC or AC power
accuracy class 0.5
serial interface, RS 232 or RS 485 (optional)
max. 3 analogue outputs
Application
The programmable measuring transducer EMBSIN 391 PV allows for the simultaneous distribution of 3 parameters of
the electrical network. Large input ranges of the parameters allow for the monitoring of almost all standardized AC
voltages and AC currents. At the measuring output of the transducer are three galvanically separated, load-independent,
analogue output signals available, which are proportionally arranged to the input parameters. These output signals (DC
voltage or DC current) can be used for monitoring /controlling of analogue or digital units.

Technical data EMBSIN 391 PV


measuring input
rated input voltage
rated input current
overload capacity
current input

50 V to 500 V AC
(phase against neutral)
0.5 A to 5.0 A AC

2 IN, constant
20 IN, 1 sec.
voltage input
1.5 UN, constant
2.0 UN,1 sec.
measuring output (analogue)
nominal current output range
(IAN), parametical
0 ... 1 mA to 0 ... 20 mA
max. burden voltage
UB ) 15 V
burden resistance current
RMAX [k1] = 15V / IAN [mA]
nominal voltage output
ranges (UAN), parametical
0 ... 1 V to 0 ... 10 V
max. burden current
20 mA
burden resistance
voltage
RMIN [k1] = UAN / 20 mA
residual ripple of the
output current
) 1 % p.p.
response time
) 300 ms

auxiliary power
universal power supply
voltage ranges
AC power supply
nominal voltages:
power input
accuracy
reference value
accuracy class
reference conditions
ambient temperature
input signal
frequency
safety
protection class

contamination class
test voltage
electrocution protection

working temperature
interface
(optional)
connection terminals

Order information see page 283


Connection diagram see page 266
Specification see page 267

weight
with AC power supply
with universal power supply

DC or AC 40...70 Hz universal
24 ... 300 V DC and 40 ... 276 V AC
45 ... 65 Hz
57.74 V, 100 V, 230 V, 400 V, 500 V
) 3 VA
end value of the input volume
class 0.5
15 ... 30 C
0 ... 100 % IN
45 ... 65 Hz
IP50
300 V, rms, connection category III
500 V, rms, connection category II
2
3 kV, rms
(acc. to IEC 61010-1: 1990)
IP 40, housing
(test wire, EN 60529)
IP 20, connection terminals
(test digit, EN 60529)
-10 C ) ) + 55 C
RS232, MODBUS RTU
RS485, MODBUS RTU
) 4.0 mm2 single wire
) 2 x 2.5 mm2 Litze
approx. 600 g
approx. 500 g

www.mbs-stromwandler.de

265

MBS AG

EMBSIN 391 PV
Programmable measuring transducers
for all electrical parameters
Connection diagram
The voltage inputs of the measuring transducer can be
connected directly to a low voltage network or to a high
voltage network via a high voltage transformer. The current inputs of the measuring transducer can be directly
connected to a low voltage network via a low voltage
current transformer or to a high voltage network via a
high voltage current transformer.

single-phase
system 1b

3-wire three-phase
system - 3b,
balanced load

Function
AC current
measuring input
AC voltage

output 1
measuring outputs

output 2
output 3

auxiliary voltage supply

interface (optional) RS232 / RS485

IL1
IL2
IL3
UL1
UL2
UL3
N
+
+
+
DC +/ AC
-/ AC
Rx / A
 / NC1)
Tx / B

Connection
1/3
4/6
7/9
2
5
8
11
15
16
17
18
19
20
13
14
21
22
23

3-wire three-phase
system - 3u,
unbalanced load

4-wire three-phase
system - 4b,
balanced load

1) -NC- do not connect !

4-wire three-phase
system - 4u,
unbalanced load

266

www.mbs-stromwandler.de

MBS AG

EMBSIN 391 PV
Programmable measuring transducers
for all electrical parameters

Specifications
Description
auxiliary voltage
measuring principle
inputs
rated input voltage
rated input current
rated frequency
outputs
number of available
analogue outputs
output voltage ranges
output current ranges
interface
measuring variables
phase current I1, I2, I3
current
and mean value current Iavg
phase to neutral voltage
U1, U2, U3 and mean value to
neutral value voltage
voltage
linked voltages
U1-U2, U2-U3, U3-U1
and mean value of the
linked voltages Uavg (pp)
frequency
active power
re-active power
apparent power
power factor
phase angle
% THD distortion factor
phase current
instantaneous
total apparent power
value monitoring
total active power
total re-active power
phase current
maximal
total apparent power
value monitoring
total active power
total re-active power

EMBSIN 391 PV
with auxiliary voltage supply
microprocessor sampling
programmable, 0...50 V to 0...500 V
programmable, 0...0.5 to 0...5 A
45...65 Hz
3 with AC/DC power supply
1 with AC power supply
programmable, -10...+10 V to -1...+1 V
programmable, -20...+20 mA to -1...+1 mA
RS232 or RS485

a, b

a, b

a,
a,
a,
a,
a,
a,
a,
a,
a,
a,
a,
a,
a,
a,
a,

b
b
b
b
b
b
b
b
b
b
b
b
b
b
b

a - measuring value is available via analogue output


b measuring value is visual via interface

www.mbs-stromwandler.de

267

MBS AG

EMBSIN 391
Programmable measuring transducers for all electrical parameters

housing for 35 mm DIN rail


Features/benefits
measuring inputs: Sinus-shaped input currents 07.5 A,
sinus-shaped input voltages 0690 V
measuring outputs: 3 simultaneously available unipolar, bipolar or live-zero
measuring outputs (current or voltage). The outputs can be assigned to several
measuring parameters
AC/DC auxiliary power supply, universal power supply
programmable interface: Serial RS232 C
Application
The EMBSIN 391 is a programmable, multi measuring transducer for electrical
power current variables. It monitors simultaneously 3 measuring variables of a
single-phase AC current or three-phase AC current network of equal or unequal
load. As an output signal 3 galvanically separated load independent DC current
signals or imprinted DC voltage signals are available, which are proportionally
arranged to the chosen measuring values of the input parameters. The measuring transducer fulfills all requirements and regulations with regard to the electromagnetic compatibility (EMV) and safety (IEC 1010 and EN 61010).

Technical data EMBSIN 391


measuring input
rated frequency fN
sinus-shaped
input current IN
sinus-shaped
input voltage UN

50/60 Hz
0 ... 7.5 A
UN = linked voltage
0 ... 690V
max. 400 V to earth !

power input from


measuring circuit
- current path
) I E 2 0.01 W
- voltage path
) UE 2 / 400 kW
interface
serial, RS232 C
measuring output, user defined
3 x load independent
DC current
-20 ... +20 mA
or
3 x imprinted DC current
-10 ... +10 V
max. burden
15 V [k1]
RB )
IAN
at current output
min. burden
UAN
RB )
[k1]
1 mA
by voltage output
output signalling limit
under overload :
- current output
1.2 x IAN (RA = 0)
) 30 V (by RA = ')
- voltage output
40 mA (RA = 0)
1.2 x UAN (RA = ')
residual ripple
of the output current
) 1 % p.p
response time of the
output signal
12 x measuring cyclus time

268

www.mbs-stromwandler.de

auxiliary voltage supply, alternatively


AC / DC power supply
24 ... 60 V AC / DC
85 ... 230 V AC / DC
(DC ... 50/60 Hz)
(DC -15 % ... + 33 %)
(AC -15 % ... + 15 %)
power input
) 5 W (7 VA)
accuracy
reference value
measuring range end value
accuracy class
class 0.5
safety
protection class
II, (protection isolated,
EN 61010-1)
electrocution protection
IP 40, housing
(test wire, EN 60529)
IP 20, connection terminals
(test digit, EN 60529)
contamination class
2
nominal isolation voltage
inputs:
300 V(2)
600 V(3)
auxiliary power: 230 V
outputs:
40 V
weight
370 g
(2) overvoltage category |||
(3) overvoltage category ||

Order information see page 286

MBS AG

Order Lists
page
FASK

Flexible clip-on current transformer (Rogowski coil) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .270

EMBSIN 100 IV

Measuring transducer for AC current, without auxiliary voltage supply . . . . . . . . . . . . . . . . .271

EMBSIN 100 I

Measuring transducer for AC current, without auxiliary voltage supply . . . . . . . . . . . . . . . . .271

EMBSIN 101 I

Measuring transducer for AC current, with auxiliary voltage supply . . . . . . . . . . . . . . . . . . . .272

EMBSIN 201 IEV

Measuring transducer for AC current, rms measurement

EMBSIN 201 IE

Measuring transducer for AC current, rms measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . .275

EMBSIN 120 UV

Measuring transducer for AC voltage, without auxiliary voltage supply . . . . . . . . . . . . . . . . .276

EMBSIN 120 U

Measuring transducer for AC voltage, without auxiliary voltage supply . . . . . . . . . . . . . . . . .276

EMBSIN 121 U

Measuring transducer for AC voltage, with auxiliary voltage supply . . . . . . . . . . . . . . . . . . . .272

EMBSIN 221 UEV

Measuring transducer for AC voltage, with auxiliary voltage supply . . . . . . . . . . . . . . . . . . . .273

EMBSIN 221 UE

Measuring transducer for AC voltage, rms measurement . . . . . . . . . . . . . . . . . . . . . . . . . . .275

EMBSIN 241 FV

Measuring transducer for frequency, with auxiliary voltage supply . . . . . . . . . . . . . . . . . . . . .277

EMBSIN 241 F

Measuring transducer for frequency, with universal AC/DC power supply . . . . . . . . . . . . . . .278

EMBSIN 241 FD

Measuring transducer for frequency difference with universal AC/DC power supply . . . . . . .278

EMBSIN 271 G

Measuring transducer for phase angle, with universal AC/DC power supply . . . . . . . . . . . . .279

EMBSIN 271 GD

Measuring transducer for phase angle difference, with universal AC/DC power supply . . . . .281

EMBSIN 281 G

Measuring transducer for power factor, with universal AC/DC power supply . . . . . . . . . . . . .279

EMBSIN 351 P

Measuring transducer for active power, with universal AC/DC power supply . . . . . . . . . . . . .282

EMBSIN 361 Q

Measuring transducer for re-active power, with universal AC/DC power supply . . . . . . . . . . .282

EMBSIN 301

Programmable measuring transducer for AC current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .283

EMBSIN 391 PV

Programmable measuring transducer for all electrical variables . . . . . . . . . . . . . . . . . . . . . . .283

. . . . . . . . . . . . . . . . . . . . . . . . . . .273

www.mbs-stromwandler.de

269

MBS AG

Order Lists
FASK Current transformers with separable, flexible measuring system
(Rogowski coils)
Features
X

1.)

2.)

3.)

4.)

Order no.
X
X X

Type
coil length
F30
30 cm
F 0
3
F40
40 cm
F 0
4
Type / length l
F60
60 cm
F 0
6
F75
75 cm
F 0
7
F100
100 cm
F 1
0
special types on request
F 9
0
measuring range
coil length
200 A AC
l = 30 cm
500 A AC
l = 30 cm
1000 A AC
l = 40 cm
Measuring current
2000 A AC
l = 60 cm
3000 A AC
l = 75 cm
3000 A AC
l = 100 cm
special value on request 1003000 A
UA [V AC]
UH [V DC]
0.500 V AC
5 V DC
1.000 V AC
5 V DC
2.000 V AC
9 V DC
Output signal UA / auxiliary voltage supply UH
3.000 V AC
12 V DC
420 mA DC
01 V DC
05 V DC
without
0.21 mV/A
power
supply
standard l
Lead / cord length
special length l

270

www.mbs-stromwandler.de

0
0
1
2
3
3
X

2
5
0
0
0
0
X

0
0
0
0
0
0
X

0
0
0
0
0
0
X

0
0
0
5
0
0

0
1
2
3
4
5
6
7
3 x 2.0 m
max. 3 x 15.0 m

1
9

MBS AG

Order Lists
EMBSIN 100 IV Measuring transducer for AC current, without auxiliary voltage supply
Features
EMBSIN 100 IV, measuring transducer for AC current
order no.: 100 I - Vxxx
1. construction
housing MBS, for 35 mm DIN rail
2. measuring range
0 ... 1 A
0 ... 5 A
nonstandard [A],
0 ... 1 A to 0 ... 7.5 A ________ A
3. output signal
0 ... 5 mA
0 ... 10 mA
0 ... 20 mA
4. additional text on the label
without additional text
with additional text

Order no.
100 I -

V
1
2
9
1
2
3
0
1

rated frequency of the measuring signal: 50/60 Hz

EMBSIN 100 I Measuring transducer for AC current, without auxiliary voltage supply
Features
EMBSIN 100 I, measuring transducer for AC current
order no.: 100 I - Mxxxx
1. construction
housing MBS, for 35 mm DIN rail
2. measuring range
0 ... 1 / 5 A
0 ... 1.2 / 6 A
9) nonstandard [A]
0 ...0.5 A to 0 ... 7.5 A
(only one measuring range!) ________ A
3. output signal
0 ... 5 mA, Ra <= 3 kOhm
0 ... 10 mA, Ra <= 1.5 kOhm
0 ... 20 mA, Ra <= 750 Ohm
4. measuring range adjustable
measuring range fixed
measuring end value adjustable approx. 10 %
5. test certificates
without test certificate
with test certificate in German
with test certificate in English

Order no.
100 I - M

M
1
2
9

1
2
3
0
1
0
D
E

rated frequency of the measuring signal: 50 / 60 Hz

www.mbs-stromwandler.de

271

MBS AG

Order Lists
EMBSIN 101 I Measuring transducer for alternating current
EMBSIN 121 U Measuring transducer for alternating voltage

Features
EMBSIN 101 I , measuring transducer for AC current
order no.: 101 I - Mxx xxx
101 I - M
EMBSIN 121 U, measuring transducer for AC voltage
order no.: 121 U - Mx xxxx
121 U- M
1. construction
housing MBS / SP1, for 35 mm DIN rail
M
2. frequency of the input voltage / input current
rated frequency 50 / 60 Hz
3. measuring range
0 ... 1 A
0 ... 5 A
Z: ______________ A
! Z: Nonstandard [ A ] : 0 ... 0.8 to 0 ... 1.2 or 0 ... 4 to 0 ... 6
0 ... 100 V
0 ... 250 V
Z: ______________ V
! Z: Nonstandard [ V ] : 0 ... 50 to 0 ... 500
max. 300 V rated voltage to earth
(rated voltages acc. to EN 61010)
4. output signal
0 ... 20 mA
4 ... 20 mA
4 ... 20 mA , 2-wire connection / feed
9: ______________ mA
! 9: Nonstandard [ mA ] : 0 ... 2.5 to 0 ... < 20
0 ... 10 V
Z: ______________ V
1 ... 5 to < ( 4... 20 )
! Z: Nonstandard [ V ] : 0 ... 5.0 to 0 ... < 10
1 ... 5 to 2 ... 10
5. auxiliary power
auxiliary voltage Uh : 24 V AC
auxiliary voltage Uh : 110 V AC
auxiliary voltage Uh : 115 V AC
auxiliary voltage Uh : 120 V AC
auxiliary voltage Uh : 230 V AC
auxiliary voltage Uh : 400 V AC, ! max. 300 V to earth!
auxiliary voltage Uh : 24 V DC
auxiliary voltage Uh : 24 V DC via output circuit
universal power supply 85 230 V AC/DC
universal power supply 24 60 V AC/DC
Uh ... rated voltage, permissible tolerances
AC : - 15 % + 15 %
DC : - 15 % + 33 %
for DC via output circuit: - 50 % + 33 %
! 1 to A not to be combined with output signal, order-no.: 3
! B not to be combined with output signal, order no.: 1, 2, 9, A, Z
6. test certificates
without test certificate
with test certificate in German
with test certificate in English

272

www.mbs-stromwandler.de

Order no.
X

1
A
B
Z
A
B
Z

1
2
3
9
A
Z

1
2
3
4
5
6
A
B
C
D

0
D
E

MBS AG

Order Lists
EMBSIN 201 IEV Measuring transducer for alternating current, true rms measuring
EMBSIN 221 UEV Measuring transducer for alternating voltage, true rms measuring

Features
EMBSIN 201 IEV, measuring transducer for AC current
effective value, order no.: 201 IE - Vxxxxxxxx
EMBSIN 221 UEV, measuring transducer for alternating voltage
effective value, order no.: 221 UE - Vxxxxxxxx
1. construction
housing MBS, for 35 mm DIN rail
2. measuring range
0 ... 1 A
0 ... 5 A
9) _______________ A
! 9) 0 0.2 A to 0 ... 6 A
0 ... 50 V
0 ... 500 V
Z) _____________________V
! Z) 0 50 V to 0 500 V
3. output signal
mA
V
4. output signal, start value
output unipolar, start value 0
output live-zero, start value 20 %
5. output signal, end value
output signal end value: 20 mA
output signal end value: 1 ... 20 mA, __________mA
output signal end value: 10 V
output signal end value: 1 ... 10 V, __________V
6. auxiliary voltage
universal power supply 24 ... 300 V DC/ 40 ... 276 V AC
AC power supply
57 V
100 V
110 V
230 V
400 V
500 V
7. type of serial interface
without interface
RS 232
RS 485
8. type of output characteristics
linear
curved (1)

Order no.
201 IE -

221 UE -

X
X

1
2

V
1
2
9
A
B
Z
1
2
1
2
1
9
A
Z

1
3
4
5
7
8
0
1
2
L
B

(1) Please take notice of the additional information in table 2 when ordering curved output characteristics.

www.mbs-stromwandler.de

273

MBS AG

Order Lists

EMBSIN 201 IEV Measuring transducer for alternating current, true rms measuring
EMBSIN 221 UEV Measuring transducer for alternating voltage, true rms measuring
Table 2
Additional information when ordering measuring transducers with curved output characteristics
When ordering measuring transducers with curved output characteristics the start and end points as well
as the position of the required curved break of the to be adjusted transmission ratio have to be defined.
Measuring transducers of the type EMBSIN 201 IEV / EMBSIN 221 UEV allow the presentation of transmission characteristics of up to 5 curved breaks.

Description
start value of the measuring value(s)
start value of the output value
end value of the measuring value (s)
end value of the output value (rt) if measuring value (e)

value of the measuring value (nx )

value of the output value (ox) if measuring value (nx)

274

www.mbs-stromwandler.de

dependent on the measuring range


0 ... +20 mA / 0 V ... +10 V
dependent on the output range
0 ) p ) +20 mA / 0 ) p ) +10 V
dependent on the measuring range
1 mA ... +20 mA / 1 V ... +10 V
dependent on the output range

Code
s
p
e

rt
n1_____
n2_____
dependent on the measuring range n3_____
n4_____
n5_____
o1_____
0 mA ... +20 mA/ 0 V ... +10 V
o2_____
dependent on the output range
o3_____
0 ) p ) +20/ 0 ) p ) +10
o4_____
o5_____

MBS AG

Order Lists
EMBSIN 201 IE Measuring transducer for alternating current
EMBSIN 221 UE Measuring transducer for alternating voltage
Features
EMBSIN 201 IE, measuring transducer for alternating current
effective value, order no.: 201 IE - Mxx xx x
201 IE EMBSIN 221 UE, measuring transducer for alternating voltage
effective value, order no.: 221 UE - Mx xx xx
221 UE1. construction
housing MBS, for 35 mm DIN rail
2. frequency of the input current/ input voltage
rated frequency 50/60 Hz
rated frequency 400 Hz
3. measuring range
0 ... 1.0 / 5.0 A
0 ... 1.2 / 6.0 A
9: ______ / ______A
Lower/higher measuring range dependent on connection availability
! 9: nonstandard [A]: 0 ... 0.1 / 0.5 to 0 ... < 1.2 / 6
measuring range end value ratio 1 : 5
0 ... 100 / \/3 V
0 ... 110 / \/3 V
0 ... 100 V
0 ... 110 V
0 ... 116.66 V
0 ... 120 V
0 ... 125 V
0 ... 133.33 V
0 ... 150 V
0 ... 250 V
0 ... 500 V !
Z) ____________V
! Z: Nonstandard [V ]: 0 ... 20 to 0 ... 690 *
with auxiliary voltage from measuring input min. 24V/ max. 230V
see selection criteria 5 digit 3+4
! * > 400 V only linked voltage!
4. output signal
0 ... 20 mA
4 ... 20 mA
9: ______________ mA
0 ... 10 V
Z: ______________ V
! 9) Nonstandard [mA]: 0 ... 1.00 to 0 ... < 20
0.2 ... 1 to < ( 4 ... 20 )
! Z) Nonstandard [V]: 0 ... 1.00 to 0 ... < 10
0.2 ... 1 to 2 ... 10
5. auxiliary voltage
Uh: 85 ... 230 V AC/DC
Uh: 24 ... 60 V AC/DC
from measuring input (>= 24 ... 60 V AC )
from measuring input (>= 85...230 V AC )
Uh : 24 V AC/ 24 ... 60 V DC
from low voltage area
Uh = rated voltage
tolerances: DC -15 ... +33 %, AC -15 ... +15 %
! 3 not to be combined with measuring range order no.: C ... L
! 4 not to be combined with measuring range order no.: A , B, L
6. response time
300 ms, standard
50 ms
7. test certificates
without test certificate
with test certificate in German
with test certificate in English

Order no.
M

X
X

M
1
2
1
2
9

A
B
C
D
E
F
G
H
J
K
L
Z

1
2
9
A
Z

1
2

1
2
3
4
5

1
2
0
D
E

www.mbs-stromwandler.de

275

MBS AG

Order Lists
EMBSIN 120 UV - Measuring transducer for alternating voltage, without auxiliary voltage supply
Features
EMBSIN 120 UV, measuring transducer for alternating voltage
order no.: 120 U - Vxxx
1. construction
housing MBS, for 35 mm DIN rail
2. measuring range
0 ... 100 / \/3 V
0 ... 110 / \/3 V
0 ... 100 V
0 ... 110 V
0 ... 250 V
0 ... 500 V !
9: ______________ V
! 9: Nonstandard [V] 0 ... 20 to 0 ... 500 V
! max. 250 V rated voltage to earth, working voltage
acc. to EN 61010!
3. output signal
0 ... 5 mA
0 ... 10 mA
0 ... 20 mA
4. additional text on the label
without additional text
with additional text

Order no.
120 U -

V
1
2
3
4
6
8

1
2
3
0
1

rated frequency of the measuring signal: 50 / 60 Hz

EMBSIN 120 U - Measuring transducer for alternating voltage, without auxiliary voltage supply
Features
EMBSIN 120 U, measuring transducer for alternating voltage
order no.: 120 U - Mxxxx
1. construction
housing MBS, for 35 mm DIN rail
2. measuring range
0 ... 100 / \/3 V
0 ... 110 / \/3 V
0 ... 120 / \/3 V
0 ... 100 V
0 ... 110 V
0 ... 116.66 V
0 ... 120 V
0 ... 125 V
0 ... 133.33 V
0 ... 150 V
0 ... 250 V
0 ... 400 V
0 ... 500 V
Z: __________ V
! Z: Nonstandard [V] 0...20 to 0...500 V
! max. 250 V rated voltage to earth, working voltage
acc. to EN 61010!
3. output signal
0 ... 5 mA, Ra <= 3 kOhm
0 ... 10 mA, Ra <= 1.5 kOhm
0 ... 20 mA, Ra <= 750 Ohm
4. measuring range adjustable
measuring range fixed
measuring end value adjustable approx. 10 %
5. test certificates
without test certificate
with test certificate in German
with test certificate in English

276

www.mbs-stromwandler.de

Order no.
120 U -

M
A
B
C
D
E
F
G
H
J
K
L
M
N
Z

1
2
3
0
1
0
D
E

MBS AG

Order Lists
EMBSIN 241 FV - Measuring transducer for frequency
Features
EMBSIN 241 FV, measuring transducer for frequency
order no.: 241 F - Vxxxxxxxx
1. construction
housing MBS, for 35 mm DIN rail
2. measuring range
40 ... 70 Hz
45 ... 55 Hz
48 ... 52 Hz
45 ... 65 Hz
55 ... 65 Hz
9: (40 Hz ) 70 Hz) fa ) fe ) 70 Hz fa______Hz fe______Hz
3. output signal
mA
V
4. output signal, start value
output signal unipolar, start value
output signal live-zero, start value 20 %
5. output signal, end value
output signal, end value: 5 mA
output signal, end value: 10 mA
output signal, end value: 20 mA
output signal, end value: 1 ... 20 mA, ______mA
output signal, end value: 10 V
output signal, end value: 1 ... 10 V, ______V
6. auxiliary voltage
universal power supply
AC power supply
57 V
100 V
110 V
230 V
400 V
500 V
7. type of serial interface
without interface
RS232
RS485
8. type of output characteristics
linear
curved (1)

Order no.
241 F-

1
2

V
1
2
3
4
5
9
1
2
1
2
1
2
3
9
A
Z

1
3
4
5
7
8
1
2
3
L
B

(1) Please take notice of the additional information in table 2 when ordering curved output characteristics.

Table 2
Additional information when ordering measuring transducers with curved output characteristics
When ordering measuring transducers with curved output characteristics the start and end points as well as the position of the
required curved break of the to be adjusted transmission ratio have to be defined. Measuring transducers of the type EMBSIN 241 FV
allow the presentation of transmission characteristics of up to 5 curved breaks.
Description
start value of the measuring value (s)
start value of the output value (p)

end value of the measuring value (e)


end value of the output value (rt) if measuring value (e)
value of the measuring value (n x )
value of the output value (ox ) if measuring value (nx )

dependent on the measuring range


0 mA ... +20 mA / 0 V ... +10 V
dependent on the output range
0 mA ) p ) +20 mA / 0 ) p ) +10 V
dependent on the measuring range
1 mA ... +20 mA / 1 V ... +10 V
dependent on the output range
dependent on the measuring range
0 mA ... +20 mA/ 0 V ... +10 V
dependent on the output range
0 ) p ) +20/ 0 ) p ) +10
www.mbs-stromwandler.de

Code
s
p
e
rt
n1 ... n5
o1 ... o5

277

MBS AG

Order Lists
EMBSIN 241 F - Measuring transducer for frequency
EMBSIN 241 FD - Measuring transducer for frequency difference
Features
EMBSIN 241 F, measuring transducer for frequency
order no.: 241 F - Mxxxxxx
EMBSIN 241 FD, measuring transducer for frequency difference
order no.: 241 FD - Mxxxxxx
1. construction
housing MBS, for 35 mm DIN rail
2. rated nominal voltage
241 FD -> generator and bus bar
input voltage
10 ... 230 V
> 230 ... 690 V
! Three-phase system:
input voltage = linked voltage
! 2 not permissible by auxiliary voltage starting from measuring input
3. measuring range
45 ... 50 ... 55 Hz
47 ... 49 ... 51 Hz
47.5 ... 50 ... 52.5 Hz
48 ... 50 ... 52 Hz
58 ... 60 ... 62 Hz
9: _____________ Hz
! 9: nonstandard [ Hz ]; limit values:
start value fa > = 10 Hz, end value fe <= 1500 Hz
fa / ( fe-fa ) < 50
fs = 50 Hz / fg = 49.5 ... 50 ... 50.5 Hz
fs = 50 Hz / fg = 47.5 ... 50 ... 52.5 Hz
fs = 50 Hz / fg = 45 ... 50 ... 55 Hz
fs = 50 Hz / fg = 40 ... 50 ... 60 Hz
fs = 60 Hz / fg = 57.5 ... 60 ... 62.5 Hz
9: ____________________________ Hz
! 9: Nonstandard [Hz]: upon request
4. output signal
0 ... 20 mA
4 ... 20 mA
9: ______________ mA
0 ... 10 V
Z: ______________ V
! 9: Nonstandard [mA]: 0 ... 1.0 to 0 ... < 20 mA
1.0 ... 0 ... 1.0 to -20 ... 0 ... 20 mA
1 ... 5 to < ( 4 ... 20 )
! Z: Nonstandard [V ] : 0 ... 1.0 to 0 ... < 10 V
0.2 ... 1 to 2 ... 10 V
-1.0 ... 0 ... 1.0 to -10 ... 0 ... 10 V
5. auxiliary voltage
Uh: 85 ... 230 V AC/DC
Uh: 24 ... 60 V AC/DC
from measuring input (>= 24 ... 60 V AC )
from measuring input (>= 85...230 V AC )
auxiliary voltage Uh: 24 V AC / 24 ... 60 V DC from
low voltage side
Uh = rated voltage
tolerances: DC -15 ... +33 %, AC -15 ... +15 %
! 3 + 4 not to be combined with input rated voltage, order no. 2
6. response time
4 periods of input frequency
2 periods of input frequency
8 periods of input frequency
16 periods of input frequency
! 1: 4 periods = standard
7. test certificates
without test certificate
with test certificate in German
with test certificate in English

278

www.mbs-stromwandler.de

Order no.
241 F -

241 FD- M

X
X

1
2

1
2
3
4
5
9

1
2
3
4
5
9

1
2
9
A
Z

1
2
3
4
5

1
2
3
4

0
D
E

MBS AG

Order Lists
EMBSIN 271 G - Measuring transducer for phase angle
EMBSIN 281 G - Measuring transducer for power factor

Features
EMBSIN 271 G, measuring transducer for phase angle
order no.: 271 G - Mxxxxxxxxx
EMBSIN 281 G, measuring transducer for power factor
order no.: 281 G - Mxxxxxxxxx
1. construction
housing MBS, for 35 mm DIN rail
2. type of measuring
for phase angle (proportional phi)
for power factor (proportional cos phi)
3. application
single-phase AC current
3- or 4-phase DC current, balanced U:
L1-L2; I : L1
L2-L3; I : L2
L3-L1; I : L3
L1-L3; I : L1
L2-L1; I : L2
L3-L2; I : L3
L1-L2; I : L3
L2-L3; I : L1
L3-L1; I : L2
4. input rated frequency
rated frequency 50 Hz
rated frequency 60 Hz
9: _______________ Hz
! 9: Nonstandard [Hz]: 10 <= f N <= 400
by auxiliary voltage from measuring input min. 40 Hz
5. input rated voltage
input voltage Un: 100 V
input voltage Un: 230 V
9: input voltage Un: ______________ V
! 3-wire system: Un = linked voltage
! 9: Nonstandard [V]: > = 10 to 690 V
by auxiliary voltage from measuring input
min. 24 V / max. 230 V, see selection criteria 9, digit 3 and 4
6. input rated current
In: 1 A
In: 5 A
9: In: _________ A (> 0.5 ... 6 A)
! 9: Nonstandard [A] upon request
7. measuring range
-60 ... 0 ... 60 el
cos phi : 0.5 ... cap ... 1 ... ind ... 0.5
9: Nonstandard: _____________
! 1 not to be combined with measuring type order no. 2
! 2 not to be combined with measuring type order no. 1
! 9 Nonstandard, measuring range within
1 ... ind ... 0 ... cap ... 1 ... ind ... 0 ... cap ... 1
or -180 ... 0 ... 180 el
clear output value, only to 175 ... 0 ... 175 el;
measuring range > = 20 el

Order no.
271 G-

281 G-

M
1
2
1
2
3
4
5
6
7
A
B
C
1
2
9

1
2
9

1
2
9

1
2
9

www.mbs-stromwandler.de

279

MBS AG

Order Lists
Continuation from page 278
EMBSIN 271 G - Measuring transducer for phase angle
EMBSIN 281 G - Measuring transducer for power factor
Features
8. output signal
0 ... 20 mA
4 ... 20 mA
9: ______________ mA
0 ... 10 V
Z: ______________ V
! 9: Nonstandard [mA]: 0 ... 1.0 to 0 ... < 20
-1.0 ... 0 ... 1.0 to -20 ... 0 ... 20
1 ... 5 to < (4 ... 20)
! Z: Nonstandard [V]: 0 ... 1.0 to 0 ... < 10
0.2 ... 1 to 2 ... 10
-1.0 ... 0 ... 1.0 to -10 ... 0 ... 10
9. auxiliary voltage
Uh: 85 ... 230 V AC/DC
Uh: 24 ... 60 V AC/DC
from measuring input (>= 24 ... 60 V AC )
from measuring input (>= 85...230 V AC )
Uh: 24 V AC / 24 ... 60 V DC from
low voltage side
Uh = rated voltage
tolerances: DC -15 ... +33 %, AC -15 ... +15 %
! 3 not to be combined with input rated voltage, order-no. 1 and 2
10. response time
4 periods of the input frequency
2 periods of the input frequency
8 periods of the input frequency
16 periods of the input frequency
! 4 periods = standard
11. test certificates
without test certificate
with test certificate in German
with test certificate in English

280

www.mbs-stromwandler.de

Order no.
1
2
9
A
Z

1
2
3
4
5

1
2
3
4

0
D
E

MBS AG

Order Lists
EMBSIN 271 GD Measuring transducer for phase angle difference
Features
EMBSIN 271 GD, measuring transducer for phase angle-difference
order no.: 271 GD - Mxxxxxxx
1. construction
housing MBS, for 35mm DIN rail
2. input rated frequency
50 Hz
60 Hz
9: _____________ Hz
! 9: Nonstandard [Hz]: * 10 to 1500
by auxiliary voltage from measuring input
40 Hz ) f n ) 400 Hz
3. input rated voltage
generator and bus bar
Un : 100 V
Un : 230V
Un : _____________ V
3-phase system: Input voltage = linked voltage
! 9: Nonstandard [V]: <= 10 to 690
by auxiliary voltage from measuring input min. 24 V max 230 V
! -> see selection criteria 6, digit 3 and 4
4. measuring range
-120 ... 0 ... +120 el
9: measuring range : _________________ e
! 9: Nonstandard [el ], measuring range within
-10 ... 0 ... 10 to -180 ... 0 ... +180
clear output value, yet only up to -175 ... 0 ... +175 el
5. output signal
0 ... 20 mA
4 ... 20 mA
9: _________________ mA
0 ... 10V
Z: _________________ V
! 9: Nonstandard [mA]: 0 ... 1.00 to 0 ... < 20
-1.0 ... 0 ... 1.00 to -20 ... 0 ... 20
1 ... 5 to < ( 4 ... 20 )
! Z: Nonstandard [V]: 0 ... 1.0 to 0 ... < 10
0.2 ... 1 to 2 ... 10
-1.0 ... 0 ... 1.0 to -10 ... 0 ... 10
6. auxiliary voltage
Uh: 85 ... 230 V AC/DC
Uh: 24 ... 60 V AC/DC
from measuring input (>= 24 ... 60 V AC )
from measuring input (>= 85...230 V AC )
Uh: 24 V AC / 24 ... 60 V DC from
low voltage side
Uh = rated voltage
tolerances: DC -15 ... +33 %, AC -15 ... +15 %
! 3 and 4 not to be combined with input rated voltage order no. 2
7. 7. response time
4 periods of the input frequency
2 periods of the input frequency
8 periods of the input frequency
16 periods of the input frequency
! 4 periods = standard
8. test certificates
without test certificate
with test certificate German
with test certificate English

order no.
271 GD -

M
1
2
9

1
2
9

1
9

1
2
9
A
Z

1
2
3
4
5

1
2
3
4

0
D
E

www.mbs-stromwandler.de

281

MBS AG

Order Lists
EMBSIN 351 P Measuring transducer for active power
EMBSIN 361 Q Measuring transducer for re-active power
Features
EMBSIN 351 P - Measuring transducer for active power
order no.: 351 P - Mx xxxxxxxx
EMBSIN 361 Q - Measuring transducer for re-active power
order no. : 361 Q - M xxxxxxxxx
1. construction
housing MBS, for 35 mm DIN rail
2. Application
3-/4-wire AC current, balanced (U:L1,L2,L3 I:L1)
3-wire AC current, unbalanced
4-phase AC current, unbalanced
3. rated input frequency
50 Hz
60 Hz
4. input rated voltage
Un; 100 ... 115 V ; ___________ V values to be stated!
Un; 200 ... 230 V ; ___________ V
Un; 380 ... 440 V ; ___________ V
Un; 600 ... 690 V ; ___________ V
Nonstandard Un; ___________ V
! 1 ... 4: True effective nominal voltages to be stated
! 9: Nonstandard [V]: > 115 to < 600
Un = linked voltage!
5. input current
In: 1 A
In: 5 A
6. measuring range
bipolar: ________________ W
unipolar: ________________ W
measuring range end values to be stated in Watt
i.e. 500W by measuring range bipolar -500 ... 500
1000 W by measuring range unipolar 0 ... 1000
permissable end value : 0.75 ... 1.3 x Un x In x \/3 [ W ]
bipolar: ______________ var
unipolar: ______________ var
measuring range end values to be stated in var
i.e. 500var by measuring range bipolar -500 ... 500
1000 Var by measuring range unipolar 0 ... 1000
permissable end value: 0.5 ... 1.0 x Un x In x \/3 [Var]
7. output signal, start value
bipolar, start value -100 % end value
unipolar, start value 0
live-zero, start value = 20 % end value
! 1 output bipolar not possible with measuring range unipolar
measuring range-order no. 2)
8. output signal, end value
end value: 20 mA
end value: 10 mA
end value: 5 mA
end value: 2.5 mA
end value: 10 V
9. auxiliary voltage supply
Uh: 85 ... 230 V DC/AC
Uh: 24 ... 60 V DC/AC
from measuring input (>= 85...230 V AC)
Uh: 24 V AC / 24 ... 60 V DC
connection via low voltage side
tolerances: DC : -15 +33 % ; AC: -15 +15 %
! 4 not to be combined with rated input voltage order-no. 3 and 4
10. test certificates
without test certificate
with test certificate German
with test certificate English

282

www.mbs-stromwandler.de

order no.
351 P-

361 Q- M

X
X

M
1
2
3
1
2
1
2
3
4
9

1
2
1
2

1
2

1
2
3

1
2
3
4
A
1
2
4
5

0
D
E

MBS AG

Order Lists
EMBSIN 301 Measuring transducer for alternating current / RMS effective value
measuring
auxiliary voltage 24 V DC

auxiliary voltage 230 V AC


Order no.
137112
137113
137114
137115
137117
137118
137119
137120
137121
137122
137123
137124

Measuring range
30 / 15 A
40 / 20 A
50 / 25 A
60 / 30 A
100 / 50 A
150 / 75 A
200 / 100 A
250 / 125 A
300 / 150 A
400 / 200 A
500 / 250 A
600 / 300 A

Order no.
137212
137213
137214
137215
137217
137218
137219
137220
137221
137222
137223
137224

Measuring range
30 / 15 A
40 / 20 A
50 / 25 A
60 / 30 A
100 / 50 A
150 / 75 A
200 / 100 A
250 / 125 A
300 / 150 A
400 / 200 A
500 / 250 A
600 / 300 A

EMBSIN 391 PV Programmable measuring transducer for all electrical parameters


Features
EMBSIN 391 PV, programmable measuring transducer
for all electrical parameters
order no.: 391 P - Vxxxxxxxxx
391 P 1. application
single-phase alternating current
3-wire direct current, balanced
3-wire direct current, unbalanced
4-wire direct current, balanced
4-wire alternating current, unbalanced
2. nominal range of the input voltage
input voltage direct connection
input voltage via voltage transformer
0 ... 50 V AC (linked voltage!)
please state value!
0 ... 500 V AC (linked voltage!)
please state value!
3. nominal value of the input current
input current via current transformer
0 ... 0.5 A AC, please state value!
0 ... 5.0 A AC, please state value!
4. auxiliary voltage
universal power supply
(24 ... 300 V DC/ 40 ... 276 V AC )
AC-voltage supply (!)
(!) units with this type of auxiliary voltage supply have only one
analogue measuring output
AC-voltage supply
57.74 V AC
63.5 V AC
100 V AC
110 V AC
230 V AC
250 V AC
400 V AC
500 V AC
5. type of serial interface
RS232
RS485
6. state upon delivery
transmission parameters are not set
parameters are arranged acc. to customer specification

Order no.

1
2
3
4
5

A
1
2
B
1
2

2
1
2
3
4
5
6
7
8
1
2
0
1
www.mbs-stromwandler.de

283

MBS AG

Order Lists
ordering schedule 1
EMBSIN 391 PV Programmable measuring transducer for all electrical parameters
Description
measuring volume

Code

true-rms-current
application
single-phase alternating current
alternating current, three-phase system
measuring range

L
L1, L2 or L3

I1, I2, I3
IN or I

0 ... 0.5 A to 0 ... 5 A

_______A

U
phase to N
U1, U2 or U3
linked voltage
U1-U2, U2-U3 or U3-U1
0 ... 50 V to 0 ... 500 V

_______

0 - _____V

system frequency
45Hz ) f ) 65 Hz (f1 ) f ) f2)

_______Hz
__ ) f ) __Hz

true-rms-voltage
single-phase alternating current

alternating current
measuring range

_______

frequency
all connections
measuring range
phase angle
single-phase alternating current

1, 2, 3 (U - I)
12, 13, 23 (U1-U2, U1-U3, U2-U3)
average value
-180 ) ) 180

alternating current, three-phase system

measuring range

defined range
(1 ) ) 2)
power factor

single-phase alternating current


alternating current

PF
PF1, PF2 or PF3
PF total supply network
-1 ) PF ) +1
defined range

measuring range
active power
single-phase alternating current
alternating current, three-phase system
measuring range
re-active power
single-phase alternating current
alternating current, three-phase system
measuring range

284

www.mbs-stromwandler.de

P
P1, P2 or P3
P-total
dependent on input value U, I
(+/-) ... W
Q
Q1, Q2 or Q3
Q-total
dependent on input value U, I
(+/-) ... var

______W
______W

______var
______var

MBS AG

Order Lists
ordering schedule 2
EMBSIN 391 PV Programmable measuring transducer for all electrical parameters
Description
measuring volume

Code

apparent power (VA)


single-phase alternating current
alternating current, three-phase system
measuring range
retrievable available values
current phases I1, I2 , I3
mean value of the total apparent power
total active power
total re-active power
measuring range

S
S1 , S2 or S3
S total
dependent on value U, I
(+/-) ... VA

_______
_______
_______
___VA ...__VA

I1 , I2 or I3
S total
P-total positive
P-total negative
Q-total -L
Q-total +C
dependent on the type of inquiry

DDI1 , DDI2 , DDI3


DDSt
DDPt+
DDPtDDQtL
DDQtC
_______

type of output characteristic


type of output characteristic

linear
curved (1)
(1) when ordering curved output characteristics please refer to the additional information in table 3
outputs
start value of the output signals
-20 mA ) I ) +20 mA current
-10 V ) U ) +10 V voltage
output value
0 ... 20 mA current output
0 ... 10 V voltage output
standard output values

L
B

_______mA
_______V
_______mA
_______V
0 ... 1 mA
0 ... 5 mA
0 ... 10 mA
0 ... 20 mA
4 ... 20 mA
-1 ... 0 ... +1 mA
-10 ... 0 ... +10 mA
-20 ... 0 ... +20 mA
0 ... 10 V
-1 ... 0 ... +1 V
-10 ... 0 ... +10 V

All output signals are limited to 120 % of the rated nominal value

ordering schedule 3
EMBSIN 391 PV - Programmable measuring transducer for all electrical parameters
Table 3
Additional information when ordering measuring transducers with curved output characteristics
When ordering measuring transducers whith curved characteristics the start and end points as well as the position of the required
curved break of the to be adjusted transmission ratio have to be defined. Measuring transducers of the type EMBSIN 391 PV allow
the presentation of transmission characteristics of up to 5 curved breaks .
Description
start value of the measuring value (s)
start value of the output value
end value of the measuring value (e)
end value of the output value (rt) if measuring value (e)
value of the measuring value (nx)
value of the output value (ox) if measuring value (nx)

Code
dependent on measuring range s
-20 mA ... +20 mA/ -10 V ... +10 V
dependent on output range
-20 ) p ) +20/ -10 ) p ) +10
dependent on measuring range
-20 mA ... +20 mA/ -10 V ... +10 V
dependent on output range
dependent on measuring range
-20 mA ... +20 mA/ -10 V ... +10 V
dependent on output range
-20 ) p ) +20/ -10 ) p ) +10
www.mbs-stromwandler.de

p
e
rt
n1 ... n5
o1 ... o5

285

MBS AG

Ordering example:
The measuring transducer EMBSIN 391 PV is installed into a 4-wire alternating current supply network with balanced
phase-loads. The measuring transducer is connected via a voltage transformer 100/0.11 kV as well as to a current
transformer of 200/5 A. The auxiliary voltage supply of the measuring transducer is effected by means of an integrated
power unit. For the communication an interface of RS485 is required. The following measuring values must be included
in the measuring feeds:

Output 1
-40 ... +40 MW
-20...+20 mA
linear

total output of the system


output current
transmission ratio

Output 2
phase angle
0 ... 10 V
start value: -180 = -10 V
curved point: 0 = 10 V
end value: 179.9 = 10 V

measuring value
output voltage

measuring value
current output

Output 3
system frequency 45 ... 55 Hz
0 ... 20 mA
48 Hz = 2 mA
52 Hz = 18 mA
55 Hz = 20 mA

Ordering text: EMBSIN 391 P - V-4; A2, 110 V; B2, 5 A; 10; 2, 1


output 1: P 40 MW; L; -20200 mA
output 2: 180; B; (180/-10; 0/0; 180/10)
output 3: f 4555 Hz; B; (45/0, 48/2, 52/18, 55/20)

type of circuit *
rated voltage range *
value of rated voltage *
rated current *
value of rated current *
auxiliary voltage supply *
serial interface *
state upon delivery *

EMBSIN 391P V-4; A2, 110 V, B2, 5A; 10; 2; 1


* order code of table 1, page 282

MBS AG

Standard Units
EMBSIN 100 I

Measuring transducer for AC current, without auxiliary voltage supply . . . . . . . . . . . . . . . . 288

EMBSIN 101 I

Measuring transducer for AC current, with auxiliary voltage supply . . . . . . . . . . . . . . . . . . . . . . . . 288

EMBSIN 201 IE

Measuring transducer for AC current, rms measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 288

EMBSIN 120 U

Measuring transducer for AC voltage, without auxiliary voltage supply. . . . . . . . . . . . . . . . . . . . . . . . . . . . 288

EMBSIN 121 U

Measuring transducer for AC voltage, with auxiliary voltage supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 289

EMBSIN 221 UE

Measuring transducer for AC voltage, rms measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 289

EMBSIN 241 F

Measuring transducer for frequency for universal AC/DC power supply . . . . . . . . . . . . . . . . . . . . . . . . . . 289

EMBSIN 281 G

Measuring transducer for power factors, with universal AC/DC power supply . . . . . . . . . . . . . . . . . . . . . 289

EMBSIN 351 P

Measuring transducer for active power, with universal AC/DC power supply . . . . . . . . . . . . . . . . . . . . . . 290

EMBSIN 361 Q

Measuring transducer for re-active power, with universal AC/DC power supply . . . . . . . . . . . . . . . . . . . . 290

www.mbs-stromwandler.de

287

MBS AG

Standard Units
EMBSIN 100 I
Construction

Measuring transducer for alternating current, without auxiliary voltage, with 2 measuring ranges
Rated frequency

housing
MBS
for 35 mm
DIN rail

Measuring range
0 ... 1.0 A / 5 A
0 ... 1.0 A / 5 A
0 ... 1.0 A / 5 A
0 ... 1.2 A / 6 A
0 ... 1.2 A / 6 A
0 ... 1.2 A / 6 A

50/60 Hz

EMBSIN 101 I
Construction

50/60 Hz

EMBSIN 201 IE
Construction

Measuring range
0 ... 1 A
0 ... 5 A
0 ... 1 A
0 ... 5 A
0 ... 1 A
0 ... 5 A
0 ... 1 A
0 ... 5 A

Output signal
0 ... 20 mA
0 ... 20 mA
4 ... 20 mA
4 ... 20 mA
0 ... 20 mA
0 ... 20 mA
4 ... 20 mA, 2-wire
4 ... 20 mA, 2-wire

Auxiliary voltage
230 V AC
230 V AC
230 V AC
230 V AC
24 V DC
24 V DC
24 V DC
24 V DC

Art.-no.
128 290
128 307
128 331
128 349
128 315
128 323
128 357
128 365

Measuring transducer for alternating current, with auxiliary voltage, with 2 measuring
ranges, effective value measuring
Rated frequency

housing
MBS
for 35 mm
DIN rail

Art.-no.
127 698
127 705
127 713
127 721
127 739
127 747

Measuring transducer for alternating current, with auxiliary voltage


Rated frequency

housing
MBS
for 35 mm
DIN rail

Output signal
0 ... 5 mA
0 ... 10 mA
0 ... 20 mA
0 ... 5 mA
0 ... 10 mA
0 ... 20 mA

50/60 Hz

Measuring range
0
0
0
0

...
...
...
...

1.0
1.0
1.2
1.2

A
A
A
A

/
/
/
/

5
5
6
6

A
A
A
A

Output signal
0
4
0
4

...
...
...
...

20
20
20
20

mA
mA
mA
mA

Auxiliary voltage DC
or AC 40400 Hz
85 ... 230 V

Art.-no.
128
128
128
128

232
240
258
266

Response time of the output value: 300 ms

EMBSIN 120 U
Construction

housing
MBS
for 35 mm
DIN rail

288

Measuring transducer for alternating voltage, without auxiliary voltage supply


Rated frequency

50/60 Hz

www.mbs-stromwandler.de

Measuring range
0 ... 100 / 33 V
0 ... 100 / 33 V
0 ... 110 / 33 V
0 ... 110 / 33 V
0 ... 100 V
0 ... 100 V
0 ... 110 V
0 ... 110 V
0 ... 120 V
0 ... 120 V
0 ... 250 V
0 ... 250 V
0 ... 500 V
0 ... 500 V

Output signal
0 ... 5 mA
0 ... 20 mA
0 ... 5 mA
0 ... 20 mA
0 ... 5 mA
0 ... 20 mA
0 ... 5 mA
0 ... 20 mA
0 ... 5 mA
0 ... 20 mA
0 ... 5 mA
0 ... 20 mA
0 ... 5 mA
0 ... 20 mA

Art.-no.
127 854
127 862
127 870
127 888
127 896
127 903
127 911
127 929
127 953
127 961
127 937
127 945
127 979
127 987

MBS AG

Standard Units
EMBSIN 121 U
Construction

Measuring transducer for alternating voltage, with auxiliary voltage supply


Rated frequency

housing
MBS
for 35 mm
DIN rail

50/60 Hz

EMBSIN 221 UE
Construction

housing
MBS
for 35 mm
DIN rail

Measuring range
0 ... 100 V
0 ... 250 V
0 ... 500 V
0 ... 100 V
0 ... 250 V
0 ... 100 V
0 ... 250 V
0 ... 500 V

Output signal
0 ... 20 mA
0 ... 20 mA
0 ... 20 mA
0 ... 20 mA
0 ... 20 mA
4 ... 20 mA, 2-wire
4 ... 20 mA, 2-wire
4 ... 20 mA, 2-wire

Auxiliary voltage
230 V AC
230 V AC
230 V AC
24 V DC
24 V DC
24 V DC
24 V DC
24 V DC

Art.-no.
127 341
127 359
127 383
127 367
127 375
127 391
127 408
127 416

Measuring transducer for alternating voltage, with auxiliary voltage supply,


effective value measuring

Rated frequency

Measuring range
0
0
0
0
0
0
0
0

50/60 Hz

...
...
...
...
...
...
...
...

100
100
120
120
250
250
500
500

Output signal

V
V
V
V
V
V
V
V

0
4
0
4
0
4
0
4

...
...
...
...
...
...
...
...

20
20
20
20
20
20
20
20

mA
mA
mA
mA
mA
mA
mA
mA

Auxiliary voltage DC
or AC 40400 Hz

85 ... 230 V

Art.-no.
127
127
127
127
127
127
127
127

440
458
466
474
507
515
482
490

response time of the output signal: 300 ms

EMBSIN 241 F
Construction

Measuring transducer for frequency, with auxiliary voltage supply


Input voltage

Measuring range
45
45
48
48
45
45
48
48

10 ... 230 V
housing
MBS
for 35 mm
DIN rail

230 ... 690 V

...
...
...
...
...
...
...
...

55
55
52
52
55
55
52
52

Output signal

Hz
Hz
Hz
Hz
Hz
Hz
Hz
Hz

0
4
0
4
0
4
0
4

...
...
...
...
...
...
...
...

20
20
20
20
20
20
20
20

mA
mA
mA
mA
mA
mA
mA
mA

Auxiliary voltage DC
or AC 40400 Hz

85 ... 230 V

Art.-no.
127
127
127
127
127
127
127
127

549
557
573
565
581
606
599
614

response time of the output volume: 4 periods of the input frequency

EMBSIN 281 G

Measuring transducer for active power factor, with auxiliary voltage supply

Construction

Input volumes

housing
MBS
for 35 mm
DIN rail

230 V AC (L1-N)
and 5 A (L1 )
400 V AC (L1-L2)
and 5 A (L1)

response time of the output volume:


rated frequency of the input volume:
measuring range:
output volume:

Output signal
0
4
0
4

...
...
...
...

20
20
20
20

mA
mA
mA
mA

Application
single-phase
alternating current
3- or 4-wire
direct current, balanced load

Auxiliary voltage DC
or AC 40400 Hz
85 ... 230 V

Art.-no.
127 648
127 664
127 656
127 672

4 periods of the input frequency


50 Hz
0.5cap1ind0.5 cos phi
proportional cos phi
www.mbs-stromwandler.de

289

MBS AG

Standard Units

EMBSIN 351 P

Measuring transducer for active power, with auxiliary voltage supply

Construction

Measuring inputs

Output signal

Application

Un: L1, L2, L3


In: L1
Un: L1, L2, L3
In: L1 and L3
Un: L1, L2, L3
In: L1, L2, L3

4 ... 20 mA

housing
MBS
for 35 mm
DIN rail

3-wire direct current


balanced load
3-wire direct current
unbalanced load
4-wire direct current
unbalanced load

input rated voltage Un:


input rated current:
rated frequency measuring input:
measuring range:

EMBSIN 361 Q

4 ... 20 mA
4 ... 20 mA

Auxiliary voltage DC
or AC 40400 Hz

Art.-no.
137 770

85 ... 230 V

137 788
137 796

400 V (linked voltage!)


5A
50 Hz
0 2 kvar

Measuring transducer for re-active power, with auxiliary voltage supply

Construction

Measuring inputs

Output signal

Application

Auxiliary voltage DC
or AC 40400 Hz

Art.-no.

housing
MBS
for 35 mm
DIN rail

Un: L1, L2, L3


I n: L1 and L3

4 ... 20 mA

3-wire alternating current


unbalanced load

85 ... 230 V

137 803

input rated voltage Un:


input rated current:
rated frequency measuring input:
measuring range:

290

400 V (linked voltage!)


5A
50 Hz
0 2 kvar

www.mbs-stromwandler.de

MBS AG

Electronic energy meter for industrial applications


Single-phase energy meter, direct measuring, clip-on onto 35 mm DIN rail
ECP6112
ECP6152
EMU6114
EMU6124

2-wire
2-wire
2-wire
2-wire

1 S0-impulse output
1 S0-impulse output, LCD
1 S0-impulse output
1 S0-impulse output

kWh
kWh
kWh
2 tariffs kWh

5 (32) A
5 (32) A
5 (63) A
5 (63) A

page
. . . . . .292
. . . . . .293
. . . . . .294
. . . . . .295

Single-phase energy and power meter, direct measuring (suitable for socket)
EMU6557 2-wire cable connection
EMU6657 2-wire suitable for socket

kWh
kWh

16 A . . . . . .296
16 A . . . . . .297

Three-phase energy meter, direct measuring, clip-on onto 35 mm DIN rail


EEH1116
EEH1126
EEH1176
EEH2116
EEH2126
EEH2176

4-wire
4-wire
4-wire
3-wire
3-wire
3-wire

1 S0-impulse output
1 S0-impulse output
1 S0-impulse output, LCD
1 S0-impulse output
1 S0-impulse output
1 S0-impulse output, LCD

kWh / kvarh
2 tariffs +/-kWh / kvarh
2 tariffs +/-kWh / kvarh
kWh / kvarh
2 tariffs +/-kWh / kvarh
2 tariffs +/-kWh / kvarh

10 (63) A
10 (63) A
10 (63) A
10 (63) A
10 (63) A
10 (63) A

. . . . . .298
. . . . . .299
. . . . . .300
. . . . . .301
. . . . . .302
. . . . . .303

5 A, 1 A
5 A, 1 A
5 A, 1 A
5 A, 1 A
5 A, 1 A
5 A, 1 A
5 A, 1 A
5 A, 1 A
5 A, 1 A

. . . . . .304
. . . . . .305
. . . . . .306
. . . . . .307
. . . . . .308
. . . . . .309
. . . . . .310
. . . . . .311
. . . . . .312

Three-phase energy transformer meter, clip-on onto 35 mm DIN rail


EEH1115
EEH1125
EEH1175
EEH2115
EEH2125
EEH2175
EWS1915
EWS1945
EWS1995

4-wire
4-wire
4-wire
3-wire
3-wire
3-wire
4-wire
4-wire
4-wire

1 S0-impulse output
1 S0-impulse output
1 S0-impulse output, LCD
1 S0-impulse output
1 S0-impulse output
1 S0-impulse output, LCD
with relay impulse output
with relay impulse output
with relay impulse output, LCD

kWh / kvarh
2 tariffs +/-kWh / kvarh
2 tariffs +/-kWh / kvarh
kWh / kvarh
2 tariffs +/-kWh / kvarh
2 tariffs +/-kWh / kvarh
+/-kWh / kvarh
2 electro-mechanical counters +/-kWh / kvarh
2 electro-mechanical counters +/-kWh / kvarh

Three-phase energy transformer meter for front panel mounting, 96 x 96 mm


EWQ1915 4-wire with relay impulse output
EWQ1945 4-wire with relay impulse output
EWQ1995 4-wire with relay impulse output, LCD

+/-kWh / kvarh
2 electro-mechanical counters +/-kWh / kvarh
2 electro-mechanical counters +/-kWh / kvarh

5 A, 1 A . . . . . .313
5 A, 1 A . . . . . .314
5 A, 1 A . . . . . .315

www.mbs-stromwandler.de

291

MBS AG

ECP 6112
Single-phase energy meter,
direct measuring
AC energy meter for clip-on onto 35 mm DIN rail

drawing

Type of energy meter

ECP6112

Mains

2-wire
rated voltage UN
tolerance value:
frequency

L-N (230 V)
230 V
-30 %...+30 %
50 Hz

Output

1 S0-impulse output
optocoupler
output impulse
connection terminal

max. 27 V DC / 10 up to 27 mA
1000 Imp/kWh
20, 21

Counter

1 counter meter for active


electro-mechanical meter
number of digits
digit height
digit width
function control

Current range

connection diagram

292

energy (kWh)
6 (5.1 digits)
4 mm
2 mm
flashing LED 1000 Imp/kWh

nominal current IN
max. current (Imax)
start current
energy consumption

5 (32) A
5A
32 A
0.004 IN
0.4 W

accuracy class
ambient temperature
connections
dimensions (mm)
weight

class 1
-25 C to +55 C
1...6 mm2
18.6 x 91 x 64
0.08 kg

Technical data

www.mbs-stromwandler.de

MBS AG

ECP 6152
Single-phase energy meter,
direct measuring
AC energy meter for clip-on onto 35 mm DIN rail

drawing

Type of energy meter

ECP6152

Mains

2-wire
rated voltage UN
tolerance value:
frequency

L-N (230 V)
230 V
-30 %...+30 %
50 Hz

Output

1 S0-impulse output
optocoupler
output impulse
connection terminal

max. 27 V DC / 10 up to 27 mA
1000 Imp/kWh
20, 21

Counter

LCD counter meter for active energy (kWh)


LCD counter meter
number of digits
6 (5.1 digits)
digit height
4 mm
digit width
2 mm
function control
flashing LED 1000 Imp/kWh

Current range

connection diagram

nominal current IN
max. current (Imax)
start current
energy consumption

5 (32) A
5A
32 A
0.004 IN
0.4 W

accuracy class
ambient temperature
connections
dimensions (mm)
weight

class 1
-25 C to +55 C
1...6 mm2
18.6 x 91 x 64
0.08 kg

Technical data

www.mbs-stromwandler.de

293

MBS AG

EMU6114
Single-phase energy meter
AC energy meter for clip-on onto 35 mm DIN rail
These energy meters are suitable for calibration
Type of energy meter

EMU12.x1m

Mains

2-wire
rated voltage UN
tolerance value
frequency
frequency range

L-N (230 V)
230 V
-20 %...+20 %
50 Hz
4565 Hz

Output

1 S0-impulse output
optocoupler
impulse duration
output impulse
impedance
connection terminal

5-30 V DC / 20 mA max.
125 ms
10 Imp/kWh
0.5 1.5 kOhm
5/6

photo is similar to the original

(S0+/S0-)
collector open
drawing
Counter

1 counter meter for active


electro-mechanical meter
number of digits
digit height
digit width
operating display
LED test

Current range
nominal current IN
max. current (I max)
consumption
start current

energy (kWh)
7 (6.1 digits)
4 mm
1.2 mm
green LED
10 Imp/Wh (invisible)
5 (63) A
5A
63 A
0.8 W
0.005 IN

Technical data
approbations
accuracy class
ambient temperature
protection class
housing
main connections
SO-impulse output
dimensions (mm)
weight

diagram

294

www.mbs-stromwandler.de

PTB approval
class 2, DIN EN 61036, active energy
-10 C to +50 C
IP 51
1 ... 10 mm2
max. 2.5 mm2
36 x 90 x 71
0.15 kg

MBS AG

EMU6124
Single-phase energy meter

AC energy meter for clip-on onto 35 mm DIN rail


These energy meters are suitable for calibration
Type of energy meter

EMU12.x1m

Mains

2-wire
rated voltage UN
tolerance value
frequency
frequency range

L-N (230 V)
230 V
-20 %...+20 %
50 Hz
4565 Hz

Output

1 S0-impulse output
optocoupler
impulse duration
output impulse
impedance
connection terminal

5-30 V DC / 20 mA max.
125 ms
10 Imp/kWh
0.5 1.5 kOhm
5/6

photo is similar to the original

drawing

(S0+/S0-)
collector open

Counter

2 counter meters for active energy HT-NT (kWh)


2 electro-mechanical meters
number of digits
7 (6.1-digits)
digit height
4 mm
digit width
1.2 mm
operating display
green LED (active tariff)
LED test
10 Imp/Wh (invisible)

Current range

5 (63) A
5A
63 A
0.8 W
0.005 IN

nominal current I N
max. current (I max)
consumption
start current
Technical data

diagram

approbations
accuracy class
ambient temperature
protection class
housing
main connections
S0-impulse output
dimensions (mm)
weight
tariff control
Tariff 2 is energized when
load of 230 V AC

PTB approval
class 2, DIN EN 61036, active energy
-10 C to +50 C
IP 51
1 ... 10 mm2
max. 2.5 mm2
36 x 90 x 71
0.17 kg
230 V AC
terminals 1 and 3 are under

www.mbs-stromwandler.de

295

MBS AG

EMU6557
Single-phase energy meter

Socket meter
Type of energy meter

EMU1.x4

Mains

2-wire
rated voltage UN
frequency
frequency range

L-N (230 V)
176 - 264 V
50 Hz
45...65 Hz

Output

cable connection

Counter

LCD counter for active energy


continuous active energy Wh/kWh
price per kWh
total energy costs
present active power W/kW
present voltage V
present current supply A
number of digits
4 (3.1 digits)
digit height
13 mm
digit width
7.5 mm
function control
display test in all functions
during start

Current range
nominal current IN
start current

16 A
16 A
10 mA

Technical data
accuracy class
ambient temperature
protection class
connection
dimensions (mm)
weight
cable length

296

www.mbs-stromwandler.de

class 2, IEC 348; IEC 1036, active


energy
-10 C to +50 C
1 IP 20
0.01 - 16 A (euro-plug)
130 x 67 x 73
0.36 kg
1.00 m

MBS AG

EMU6657
Single-phase energy meter
Socket meter
Type of energy meter

EMU-Check

Mains

2-wire
rated voltage UN
frequency
frequency range

L-N (230 V)
140 - 264 V
50 Hz
4565 Hz

Output

socket

Counter

LCD counter for active energy


continuous active power Wh/kWh
level (adjusted starting value in kW)
time (total time via level in h)
present active power W/kW
present voltage V
present current supply A
present power factor
number of digits
6 (5.1 digits)
digit height
7 mm
digit width
3.5 mm
function control
display test in all functions
during start

Current range
nominal current I N
start current

16 A
16 A
10 mA

accuracy class
ambient temperature
protection class
connections
dimensions (mm)
weight

class 2, IEC 1036, active energy


-10 C to +50 C
1 IP 20
0.01 - 16 A (euro-plug)
130 x 67 x 73
0.15 kg

Technical data

power
W, kW

start value

time

time measuring

time

www.mbs-stromwandler.de

297

MBS AG

EEH1116
Three-phase energy meter
AC energy meter for clip-on onto 35 mm DIN rail

drawing

Type of energy meter

EEH1116

Mains

4-wire
rated voltage U N
tolerance value
consumption
frequency
frequency range

L-N (230 V)
230 V
-20 %...+15 %
< 3.0 W/phase
50 Hz
4565 Hz

Output

1 S0-impulse output
optocoupler
impulse duration
output impulse
connection terminal

40 V / 27 mA max.
100 ms +/-50 %
1000 Imp/kWh
40 / 41

(S0)
collector open
(option)
communication

RS485
connection
cable type
max. cable length
connection
isolation
transmission system
format type
transmission time
connection A and B
max. linked meters

diagram

Counter

1 counter meter for active


electro-mechanical meter
number of digits
digit height
digit width
LED test
LED operation

(option)
1 meter for reactive energy (kvarh)
Current range
nominal current I N
max. current I max
consumption
start current

EEH1316
multi-drop
screened, wound pair
1000 m
terminal screw
3.7 kV rms for 1 min. between
all meters and other units
asynchronous
MODBUS RTU
1200 to 19200 bits/s
120 Ohm
32
energy (kWh)
7 (6.1 digits)
4 mm
1.2 mm
1000 Imp/kWh
status

(red)
(red)

EEH1106
10 (63) A
10 A
63 A
< 0.02 W/phase
0.004 IN

Technical data

Option
EEH5116
equally load phases

construction

approbations
active energy
reactive energy
housing

dimensions (mm)
weight
mounting
climatic conditions
ambient temperature operation
storage
protection class
current terminals
control terminals

298

www.mbs-stromwandler.de

EN 61036
class 1
EN 61268
class 2
PA6.6 in conformity
with UL 94 V-0
108 x 90 x 72
0.6 kg
DIN rail acc. to DIN EN 50022
EN 61036
interior meter
-20 C to +55 C
-25 C to +70 C
2
< 16 mm2
< 2.5 mm2

MBS AG

EEH1126
Three-phase energy meter
AC energy meter for dual tariff, suitable for clip-on onto 35 mm DIN rail

drawing

Type of energy meter

EEH1126

Mains

4-wire
rated voltage U N
tolerance value
consumption
frequency
frequency range

L-N (230 V)
230 V
-20 %...+15 %
< 3.0 W/phase
50 Hz
45...65 Hz

Output

1 S0-impulse output
optocoupler
impulse duration
output impulse
connection terminal

40 V / 27 mA max.
100 ms +/-50 %
1000 Imp/kWh
40 / 41 / 42

(S0)
collector open
(option)
communication

RS485
connection
cable type
max. cable length
connection
isolation
transmission system
format type
transmission time
connection A and B
max. linked meters

diagram

Counter

EEH1426
multi-drop
screened, wound pair
1000 m
terminal screw
3.7 kV rms for 1 min. between
all meters and other units
asynchronous
MODBUS RTU
1200 to 19200 bits/s
120 Ohm
32

2 counter meters for active energy HT-NT (kWh)


2 electro-mechanical meters
number of digits
7 (6.1 digits)
digit height
4 mm
digit width
1.2 mm
LED test
1000 Imp/kWh
(red)
LED operation
status (tariffs)
(red)

(option)
2 meters for active/reactive energy (kvarh)
2 meters for active energy (import/export) (kWh)
Current range
nominal current I N
max. current Imax
consumption
start current

EEH1236
EEH1246
10 (63) A
10 A
63 A
< 0.02 W/phase
0.004 IN

Technical data

Option
EEH5226
equally load phases

construction

ambient
temperature

approbations
active energy
reactive energy
housing

EN 61036
class 1
EN 61268
class 2
PA6.6 in conformity
with UL 94 V-0
dimensions (mm)
108 x 90 x 72
weight
0.6 kg
mounting
DIN rail acc. to DIN EN 50022
climatic conditions
EN 61036
interior meter
operation
-20 C to +55 C
storage
-25 C to +70 C
protection class
2
current terminals
< 16 mm2
control terminals
< 2.5 mm2
tariff start
230 V AC
Tariff 2 is energized when terminals 13 and 15
are under load of 230 V AC
www.mbs-stromwandler.de

299

MBS AG

EEH1176
Three-phase energy meter
AC energy meter for dual tariff, suitable for clip-on onto 35 mm DIN rail
Type of energy meter

EEH1176

Mains

4-wire
rated voltage UN
tolerance value
consumption
frequency
frequency range

L-N (230 V)
230 V
-20 %...+15 %
< 3.0 W/phase
50 Hz
45...65 Hz

Output

1 S0-impulse output
optocoupler
impulse duration
output impulse
connection terminal

40 V / 27 mA max.
100 ms +/-50 %
1000 Imp/kWh
40 / 41

photo is similar to the original

drawing

(S0)
collector open
(option)
communication

RS485
connection
cable type
max. cable length
connection
isolation
transmission system
format type
transmission time
connection A and B
max. linked meters

diagram

Counter

EEH1476
multi-drop
screened, wound pair
1000 m
terminal screw
3.7 kV rms for 1 min. between
all meters and other units
asynchronous
MODBUS RTU
1200 to 19200 bits/s
120 Ohm
32

LCD counter meter for active energy HT-NT (kWh)


LCD counter
number of digits
2 x 9 (8.1 digits)
digit height
4.86 mm
digit width
2.96 mm

(option)
2 meters for active/reactive energy (kvarh)
2 meters for active energy (import/export) (kWh)
Current range
nominal current IN
max. current Imax
consumption
start current

EEH1286
EEH1296
10 (63) A
10 A
63 A
< 0.02 W/phase
0.004 IN

Technical data

Option
EEH5276
equal load phases

300

approbations
active energy
EN 61036
class 1
reactive energy
EN 61268
class 2
construction
housing
PA6.6 in conformity with UL 94 V-0
dimensions (mm)
108 x 90 x 72
weight
0.6 kg
mounting
DIN rail acc. to DIN DIN EN 50022
climatic conditions
EN 61036
interior meter
ambient temperature operation
-20 C to +55 C
storage
-25 C to +70 C
protection class
2
current terminals
< 16 mm2
control terminals
< 2.5 mm2
tariff start
230 V AC
Tariff 2 is energized when terminals 13 and 15
are under load of 230 V AC

www.mbs-stromwandler.de

MBS AG

EEH2116
Three-phase energy meter
AC energy meter for dual tariff, suitable for clip-on onto 35 mm DIN rail
Type of energy meter

EEH2116

Mains

3-wire
rated voltage UN
tolerance value
consumption
frequency
frequency range

L-L (400 V)
230 V
-20 %...+15 %
< 3.0 W/phase
50 Hz
45...65 Hz

Output

1 S0-impulse output
optocoupler
impulse duration
output impulse
connection terminal

40 V / 27 mA max.
100 ms +/-50 %
1000 Imp/kWh
40 / 41

photo is similar to the original

drawing

(S0)
collector open
(option)
communication

RS485
connection
cable type
max. cable length
connection
isolation
transmission system
format type
transmission time
connection A and B
max. linked meters

diagram
Counter

1 counter meter for active


electro-mechanical meter
number of digits
digit height
digit width
LED test
LED operations

(option)
1 meter for reactive energy (kvarh)
Current range
nominal current IN
max. current Imax
consumption
start current

EEH2316
multi-drop
screened, wound pair
1000 m
terminal screw
3.7 kV rms for 1 min. between
all meters and other units
asynchronous
MODBUS RTU
1200 to 19200 bits/s
120 Ohm
32
energy (kWh)
7 (6.1 digits)
4 mm
1.2 mm
1000 Imp/kWh
status

(red)
(red)

EEH2106
10 (63) A
10 A
63 A
< 0.02 W/phase
0.004 IN

Technical data

option
EEH8116
equally load phases

approbations
active energy
reactive energy
construction
housing
dimensions (mm)
weight
mounting
climatic conditions
ambient temperature operation
storage
protection class
current terminals
control terminals

EN 61036
class 1
EN 61268
class 2
PA6.6 in conformity with UL 94 V-0
108 x 90 x 72
0.6 kg
DIN rail acc. to DIN EN 50022
EN 61036
interior meter
-20 C to +55 C
-25 C to +70 C
2
< 16 mm2
< 2.5 mm2

www.mbs-stromwandler.de

301

MBS AG

EEH2126
Three-phase energy meter
AC energy meter for dual tariff, suitable for clip-on onto 35 mm DIN rail
Type of energy meter

EEH2126

Mains

3-wire
rated voltage UN
tolerance value
consumption
frequency
frequency range

L-L (400 V)
230 V
-20 %...+15 %
< 3.0 W/phase
50 Hz
45...65 Hz

Output

1 S0-impulse output
optocoupler
impulse duration
output impulse
connection terminal

40 V / 27 mA max.
100 ms +/-50 %
1000 Imp/kWh
40 / 41 / 42

photo is similar to the original

drawing

(S0)
collector open
(option)
communication

RS485
connection
cable type
max. cable length
connection
isolation
transmission system
format type
transmission time
connection A and B
max. linked meters

diagram

Counter

EEH2426
multi-drop
screened, wound pair
1000 m
terminal screw
3.7 kV rms for 1 min. between
all meters and other units
asynchronous
MODBUS RTU
1200 to 19200 bits/s
120 Ohm
32

2 counter meters for active energy HT-NT (kWh)


2 electro-mechanical meters
number of digits
7 (6.1 digits)
digit height
4 mm
digit width
1.2 mm
LED test
1000 Imp/kWh
(red)
LED operation
status (tariffs)
(red)

(option)
2 meters for active/reactive energy (kWh/kvarh)
2 meters for active energy (import/export) kWh)
Current range
nominal current IN
max. current Imax
consumption
start current

EEH2236
EEH2246
10 (63) A
10 A
63 A
< 0.02 W/current path
0.004 IN

Technical data

option
EEH8226
equally load phases

302

approbations
active energy
reactive energy
housing

EN 61036
class 1
EN 61268
class 2
construction
PA6.6 in conformity
with UL 94 V-0
dimensions (mm)
108 x 90 x 72
weight
0.6 kg
mounting
DIN rail acc. to DIN EN 50022
climatic conditions
EN 61036
interior meter
ambient temperature operation
-20 C to +55 C
storage
-25 C to +70 C
protection class
2
current terminals
< 16 mm2
control terminals
< 2.5 mm2
tariff start
230 V AC
Tariff 2 is energized when terminals 13 and 15
are under load of 230 V AC

www.mbs-stromwandler.de

MBS AG

EEH2176
Three-phase energy meter
AC energy meter for dual tariff, suitable for clip-on onto 35 mm DIN rail
Type of energy meter

EEH2176

Mains

3-wire
rated voltage UN
tolerance value
consumption
frequency
frequency range

L-L (400 V)
230 V
-20 %...+15 %
< 3.0 W/phase
50 Hz
45...65 Hz

Output

1 S0-impulse output
optocoupler
impulse duration
output impulse
connection terminal

40 V / 27 mA max.
100 ms +/-50 %
1000 Imp/kWh
40 / 41 / 42

photo is similar to the original

drawing

(S0)
collector open
(option)
communication

RS485
connection
cable type
max. cable length
connection
isolation
transmission system
format type
transmission time
connection A and B
max. linked meters

diagram

Counter

EEH2476
multi-drop
screened, wound pair
1000 m
terminal screw
3.7 kV rms for 1 min. between
all meters and other units
asynchronous
MODBUS RTU
1200 to 19200 bits/s
120 Ohm
32

LCD counter meter for active energy HT-NT (kWh)


number of digits
2 x 9 (8.1 digits)
digit height
4.86 mm
digit width
2.96 mm

(option)
2 meters for active/reactive energy (kWh/kvarh)
2 meters for active energy (import/export) kWh)
Current range
nominal current I N
max. current I max
consumption
start current

EEH2286
EEH2296
10 (63) A
10 A
63 A
< 0.02 W/current path
0.004 I N

Technical data
approbations
active energy
reactive energy
housing

option
EEH8276
equally load phases

EN 61036
class 1
EN 61268
class 2
construction
PA6.6 in conformity
with UL 94 V-0
dimensions (mm)
108 x 90 x 72
weight
0.6 kg
mounting
DIN rail acc. to DIN EN 50022
climatic conditions
EN 61036
interior meter
ambient temperature operation
-20 C to +55 C
storage
-25 C to +70 C
protection class
2
current terminals
< 16 mm2
control terminals
< 2.5 mm2
tariff start
230 V AC
Tariff 2 is energized when terminals 13 and 15
are under load of 230 V AC

www.mbs-stromwandler.de

303

MBS AG

EEH1115
Three-phase energy transformer meter
AC energy transformer meter, suitable for clip-on onto 35 mm DIN rail
Type of energy meter
EEH1115xxxx
xxxx declaring the primary current is absolutely necessary
Mains
4-wire
L-N (230 V)
rated voltage UN
230 V
tolerance value
-20 %... +15 %
consumption
< 3.0 VA
frequency
50 Hz
frequency range
45...65 Hz
Output

drawing

(S0)
collector open
(option)
communication

1 S0-impulse output
optocoupler
impulse duration
output impulse
connection terminal
RS485
connection
cable type
max. cable length
connection
isolation
transmission system
format type
transmission time
connection A and B
max. linked meters

diagram

Counter

diagram
(option)

1 counter meter for active


electro-mechanical meter
number of digits
digit height
digit width
LED test
LED operation
reactive energy

Current range

(option)
Primary current

nominal current I N
max. current Imax
consumption
start current
nominal current IN

40 V / 27 mA max.
100 ms +/-50 %
1000 Imp/kWh
40 / 41
EEH1315xxxx
multi-drop
screened, wound pair
1000 m
terminal screw
3.7 kV rms for 1 min. between
all meters and other units
asynchronous
MODBUS RTU
1200 to 19200 bits/s
120 Ohm
32
energy
7 (6.1 digits)
4 mm
1.2 mm
1000 Imp/kWh
status
EEH1105xxxx

(red)
(red)

5A
5A
6A
< 0.02 W/current path
0.002 IN
1A
EEH1111xxxx

0.5 A to 2000 A
If not stated otherwise, the standard version 5 A or 1 A
will be supplied

Technical data
option
EEH5115xxxx
equally load phases

304

approbations
active energy
reactive energy
construction
housing
dimensions (mm)
weight
mounting
climatic conditions
ambient temperature operation
storage
protection class
current terminals
control terminals

www.mbs-stromwandler.de

EN 61036
class 1
EN 61268
class 2
PA6.6 in conformity with UL 94 V-0
108 x 90 x 72
0.6 kg
DIN rail acc. to DIN EN 50022
EN 61036
interior meter
-20 C to +55 C
-25 C to +70 C
2
< 10 mm2
< 2.5 mm2

MBS AG

EEH1125
Three-phase energy transformer meter
AC energy transformer meter for dual tariff, suitable for clip-on onto 35 mm DIN rail

drawing

diagram

diagram

option
EEH5225
equally load phases

Type of energy meter


EEH1125xxxx
xxxx declaring the primary current is absolutely necessary
Mains
4-wire
L-N (230 V)
rated voltage UN
230 V
tolerance value
-20 %...+15 %
consumption
< 3.0 W/phase
frequency
50 Hz
frequency range
45...65 Hz
Output
1 S0-impulse output
optocoupler
40 V / 27 mA max.
(S0)
impulse duration
100 ms +/-50 %
collector open
output impulse
1000 Imp/kWh
connection terminal
40 / 41 / 42
(option)
communication
RS485
EEH1425xxxx
connection
multi-drop
cable type
screened, wound pair
max. cable length
1000 m
connection
terminal screw
isolation
3.7 kV rms for 1 min. between
all meters and other units
transmission system
asynchronous
format type
MODBUS RTU
transmission time
1200 to 19200 bits/s
connection A and B
120 Ohm
max. linked meters
32
Counter
2 counter meters for active energy HT-NT (kWh)
2 electro-mechanical meters
number of digits
7 (6.1 digits)
digit height
4 mm
digit width
1.2 mm
LED test
1000 Imp/kWh
(red)
LED operation
status (tariffs)
(red)
(option)
2 meters for active/reactive energy (kWh/kvarh)
EEH1235xxxx
2 meters for active energy (import/export) (kWh)
EEH1245xxxx
Current range
5A
nominal current I N
5A
max. current I max
6A
consumption
< 0.02 W/current path
start current
0.002 IN
(option)
nominal current IN
1A
EEH1221xxxx
Primary current
0.5 A to 2000 A
If not stated otherwise, the standard version 5 A or 1 A
will be supplied
Technical data
approbations
active energy
EN 61036
class 1
reactive energy
EN 61268
class 2
construction
housing
PA6.6 in conformity
with UL 94 V-0
dimensions (mm)
108 x 90 x 72
weight
0.6 kg
mounting
DIN rail acc. to DIN EN 50022
climatic conditions
EN 61036
interior meter
ambient temperature operation
-20 C to +55 C
storage
-25 C to +70 C
protection class
2
current terminals
< 10 mm2
control terminals
< 2.5 mm2
tariff start
230 V AC
Tariff 2 is energized when terminals 13 and 15 are under load
of 230 V AC
www.mbs-stromwandler.de

305

MBS AG

EEH1175
Three-phase energy transformer meter
AC energy transformer meter for dual tariff, suitable for clip-on onto 35 mm DIN rail

photo is similar to the original

drawing

diagram

Type of energy meter


EEH1175xxxx
xxxx declaring the primary current is absolutely necessary
Mains
4-wire
L-N (230 V)
rated voltage UN
230 V
tolerance value
-20 %...+15 %
consumption
< 3.0 W
frequency
50 Hz
frequency range
45...65 Hz
Output
1 S0-impulse output
optocoupler
40 V / 27 mA max.
(S0)
impulse duration
100 ms +/-50 %
collector open
output impulse
1000 Imp/kWh
connection terminal
40 / 41
(option)
communication
RS485
EEH1475xxxx
connection
multi-drop
cable type
screened, wound pair
max. cable length
1000 m
connection
terminal screw
isolation
3.7 kV rms for 1 min. between
all meters and other units
transmission system
asynchronous
format type
MODBUS RTU
transmission time
1200 to 19200 bits/s
connection A and B
120 Ohm
max. linked meters
32
Counter

LCD counter meter for active energy HT-NT (kWh)


number of digits
2 x 9 (8.1-digits)
digit height
4.86 mm
digit width
2.96 mm

(option)
2 meters for active/reactive energy (kWh/kvarh)
2 meters for active energy (import/export) (kWh)
Current range

(option)
Primary current

nominal current I N
max. current I max
consumption
start current
nominal current IN

EEH1285xxxx
EEH1295xxxx
5A
5A
6A
< 0.02 W/current path
0.002 IN
1A
EEH1271xxxx

0.5 A to 2000 A
If not stated otherwise, the standard version 5 A or 1 A
will be supplied

Technical data

option
EEH5275xxxx
equally load phases

306

approbations
active energy
reactive energy
construction
housing
dimensions (mm)
weight
mounting
climatic conditions
ambient temperature operation
storage
protection class
current terminals
control terminals
tariff start
Tariff 2 is energized when
of 230 V AC

www.mbs-stromwandler.de

EN 61036
class 1
EN 61268
class 2
PA6.6 in conformity with UL 94 V-0
108 x 90 x 72
0.6 kg
DIN rail acc. to DIN EN 50022
EN 61036
interior meter
-20 C to +55 C
-25 C to +70 C
2
< 10 mm2
< 2.5 mm2
230 V AC
terminals 13 and 15 are under load

MBS AG

EEH2115
Three-phase energy transformer meter
AC energy transformer meter for clip-on onto 35 mm DIN rail

photo is similar to the original

drawing

Type of energy meter


EEH2115xxxx
xxxx declaring the primary current is absolutely necessary
Mains
3-wire
L-L (400 V)
rated voltage UN
230 V
tolerance value
20 %...+15 %
consumption
< 3.0 W/phase
frequency
50 Hz
frequency range
45...65 Hz
Output
(S0)
collector open
(option)
communication

1 S0-impulse output
optocoupler
impulse duration
output impulse
connection terminal
RS485
connection
cable type
max. cable length
connection
isolation
transmission system
format type
transmission time
connection A and B
max. linked meters

diagram

Counter

(option)

1 counter meter for active


electro-mechanical meter
number of digits
digit height
digit width
LED test
LED operation
reactive energy (kvarh)

Current range

(option)
Primary current

nominal current I N
max. current Imax
consumption
start current
nominal current I N

40 V / 27 mA max.
100 ms +/-50 %
1000 Imp/kWh
40 / 41
EEH2315xxxx
multi-drop
screened, wound pair
1000 m
terminal screw
3.7 kV rms for 1 min. between
all meters and other units
asynchronous
MODBUS RTU
1200 to 19200 bits/s
120 Ohm
32
energy (kWh)
7 (6.1 digits)
4 mm
1.2 mm
1000 Imp/kWh
status
EEH2105xxxx

(red)
(red)

5A
5A
6A
< 0.02 W/current path
0.002 I N
1A
EEH2111xxxx

0.5 A to 2000 A
If not stated otherwise, the standard version 5 A or 1 A
will be supplied

Technical data
option
EEH8115xxxx
equally load phases

approbations
active energy
reactive energy
construction
housing
dimensions (mm)
weight
mounting
climatic conditions
ambient temperature operation
storage
protection class
current terminals
control terminals

EN 61036
class 1
EN 61268
class 2
PA6.6 in conformity with UL 94 V-0
108 x 90 x 72
0.6 kg
DIN rail acc. to DIN EN 50022
EN 61036
interior meter
-20 C to +55 C
-25 C to +70 C
2
< 10 mm2
< 2.5 mm2

www.mbs-stromwandler.de

307

MBS AG

EEH2125
Three-phase energy transformer meter
AC energy transformer meter for dual tariff for clip-on onto 35 mm DIN rail

photo is similar to the original

drawing

diagram

option
EEH8225xxxx
equally load phases

308

Type of energy meter


EEH2125xxxx
xxxx declaring the primary current is absolutely necessary
Mains
3-wire
L-L (400 V)
rated voltage UN
230 V
tolerance value
-20 %...+15 %
consumption
< 3.0 W/phase
frequency
50 Hz
frequency range
45...65 Hz
Output
1 S0-impulse output
optocoupler
40 V / 27 mA max.
(S0)
impulse duration
100 ms +/-50 %
collector open
output impulse
1000 Imp/kWh
connection terminal
40 / 41 / 42
(option)
communication
RS485
EEH2425xxxx
connection
multi-drop
cable type
screened, wound pair
max. cable length
1000 m
connection
terminal screw
isolation
3.7 kV rms for 1 min. between
all meters and other units
transmission system
asynchronous
format type
MODBUS RTU
transmission time
1200 to 19200 bits/s
connection A and B
120 Ohm
max. linked meters
32
Counter
2 counter meters for active energy HT-NT (kWh)
2 electro-mechanical meters
number of digits
7 (6.1 digits)
digit height
4 mm
digit width
1.2 mm
LED test
1000 Imp/kWh
(red)
LED operation
status (tariffs)
(red)
(option)
2 meters for active/reactive energy (kWh/kvarh)
EEH2235xxxx
2 meters for active energy (kWh)
EEH2245xxxx
Current range
5A
nominal current IN
5A
max. current Imax
6A
consumption
< 0.02 W/current path
start current
0.002 IN
(option)
nominal current IN
1A
EEH2221xxxx
Primary current
0.5 A to 2000 A
If not stated otherwise, the standard version 5 A or 1 A
will be supplied.
Technical data
approbations
active energy
EN 61036
class 1
reactive energy
EN 61268
class 2
construction
housing
PA6.6 in conformity with UL 94 V-0
dimensions (mm)
108 x 90 x 72
weight
0.6 kg
mounting
DIN rail acc. to DIN EN 50022
climatic conditions
EN 61036 interior meter
operating temperature
-20 C to +55 C
storage temperature
-25 C to +70 C
protection class
2
current terminals
< 10 mm2
control terminals
< 2.5 mm2
tariff start
230 V AC
Tariff 2 is energized when terminals 13 and 15 are under load
of 230 V AC

www.mbs-stromwandler.de

MBS AG

EEH2175
Three-phase energy transformer meter
AC energy transformer meter for dual tariff for clip-on onto 35 mm DIN rail

photo is similar to the original

drawing

diagram

Type of energy meter


EEH2175xxxx
xxxx declaring the primary current is absolutely necessary
Mains
3-wire
L-L (400 V)
rated voltage UN
230 V
tolerance value
-20 %...+15 %
consumption
< 3.0 W
frequency
50 Hz
frequency range
45...65 Hz
Output
1 S0-impulse output
optocoupler
40 V / 27 mA max.
(S0)
impulse duration
100 ms +/-50 %
collector open
output impulse
1000 Imp/kWh
connection terminal
40 / 41
(option)
communication
RS485
EEH2475xxxx
connection
multi-drop
cable type
screened, wound pair
max. cable length
1000 m
connection
terminal screw
isolation
3.7 kV rms for 1 min. between
all meters and other units
transmission system
asynchronous
format type
MODBUS RTU
transmission time
1200 to 19200 bits/s
connection A and B
120 Ohm
max. linked meters
32
Counter

LCD counter meter for active energy HT-NT (kWh)


number of digits
2 x 9 (8.1 digits)
digit height
4.86 mm
digit width
2.96 mm

(option)
2 meters for active/reactice energy (kWh/kvarh)
2 meters for active energy (import/export) (kWh)
Current range

(option)
Primary current

EEH2285xxxx
EEH2295xxxx
5A
5A
6A
< 0.02 W/current path
0.002 IN
1A
EEH2271xxxx

nominal current I N
max. current Imax
consumption
start current
nominal current IN

0.5 A to 2000 A
If not stated otherwise, the standard version 5 A or 1 A
will be supplied

Technical data

option
EEH8275xxxx
equally load phases

approbations
active energy
reactive energy
construction
housing
dimensions (mm)
weight
mounting
climatic conditions
ambient temperature operation
storage
protection class
current terminals
control terminals
tariff start
Tariff 2 is energized when
of 230 V AC

EN 61036
class 1
EN 61268
class 2
PA6.6 in conformity with UL 94 V-0
108 x 90 x 72
0.6 kg
DIN rail acc. to DIN EN 50022
EN 61036
interior meter
-20 C to +55 C
-25 C to +70 C
2
< 10 mm2
< 2.5 mm2
230 V AC
terminals 13 and 15 are under load

www.mbs-stromwandler.de

309

MBS AG

EWS1915
Three-phase energy transformer meter
AC energy transformer meter for clip-on onto 35 mm DIN rail

photo is similar to the original

Type of energy meter


EWS1915xxxx
xxxx declaring the primary current is absolutely necessary
Mains
4-wire
L-N (230 V)
rated voltage UN
57 V, 100 V, 230 V, 400 V
tolerance value
-20 %...+20 %
consumption
< 3.0 W/phase
frequency
50 Hz
frequency range
45...65 Hz
Output

drawing

(option)
(S0)
collector open

Counter

1 relay impulse output


relay
impulse duration
max. load
output impulse
max. impulse
EWS1115xxxx
optocoupler
impulse duration
output impulse
output impulse
impedance
1 counter meter for active
electro-mechanical meter
number of digits
digit height
digit width
LED test

diagram

Current range
nominal current I N
max. current I max
consumption
start current
nominal current IN

(option)
Primary current

250 V, 6 A, 50 Hz
100 ms
1500 W
1 Imp/kWh
4000/h
40 V / 27 mA max.
100 ms +/-50 %
1 Imp/Wh
(30...250 A)
10 Imp/Wh
(300...2000 A)
100 Ohm
energy (kWh)
7 (7.0 digits)
4 mm
1.2 mm
8 Imp/kWh
xxxx/5 A (dip-switch setting)
5A
6A
< 0.1 W/current path
0.002 IN
xxxx/1 A
EWS1911xxxx

0.5 A to 2000 A
If not stated otherwise, the standard version 30/5 A or 30/1 A
will be supplied

Technical data

option
EWS5915xxxx
equally load phases

approbations
active energy
construction
polycarbonate housing
colour
dimensions (mm)
weight
mounting
ambient temperature operation
storage
protection class

EN 61036
class 1
acc. to UL 94 V-0
RAL 7035
106 x 90 x 58
0.3 kg
DIN rail acc. to DIN EN 50022
-10 C to +60 C
-40 C to +70 C
2

setting of the 4-pole dip switch

deviating primary currents are programmed at works


according to the details of the order.
310

www.mbs-stromwandler.de

MBS AG

EWS1945
Three-phase energy transformer meter
AC energy transformer meter for clip-on onto 35 mm DIN rail
Type of energy meter
EWS1945xxxx
xxxx declaring the primary current is absolutely necessary
Mains

4-wire
rated voltage U N
tolerance value
consumption
frequency
frequency range

Output

1 relay impulse output


relay
impulse duration
max. load
output impulse
max. impulse
EWS1145xxxx
optocoupler
impulse duration
output impulse
output impulse
impedance

photo is similar to the original

drawing

(option)
(S0)
collector open

diagram

Counter

L-N (230 V)
57 V, 100 V, 230 V, 400 V
-20 %...+20 %
< 3.0 W/phase
50 Hz
45...65 Hz

250 V, 6 A, 50 Hz
100 ms
1500 W
1 Imp/kWh
4000/h
40 V / 27 mA max.
100 ms +/-50 %
1 Imp/Wh
(30...250 A)
10 Imp/Wh
(300...2000 A)
100 Ohm

2 counter meters for active energy (import/export) (kWh)


2 electro-mechanical meters
number of digits
7 (7.0 digits)
digit height
4 mm
digit width
1.2 mm
LED test
8 Imp/kWh

(option)
2 meters for active/reactive energy (kWh/kvarh)
Current range

xxxx/5 A (dip-switch setting)


5A
6A
< 0.1 W/current path
0.002 IN
xxxx/1 A
EWS1941xxxx

nominal current IN
max. current Imax
consumption
start current
nominal current IN

(option)
Primary current

EWS1935

0.5 A to 2000 A
If not stated otherwise, the standard version 30/5 A or 30/1 A
will be supplied

Technical data

option
EWS5945xxxx
equally load phases

approbations
active energy
construction
polycarbonate housing
colour
dimensions (mm)
weight
mounting
ambient temperature operation
storage
protection class

EN 61036
class 1
acc. to UL 94 V-0
RAL 7035
106 x 90 x 58
0.3 kg
DIN rail acc. to DIN EN 50022
-10 C to +60 C
-40 C to +70 C
2

setting of the 4-pole dip switch

deviating primary currents are programmed at works


according to the details of the order.
www.mbs-stromwandler.de

311

MBS AG

EWS1995
Three-phase energy transformer meter
AC energy transformer meter for clip-on onto 35 mm DIN rail
Type of energy meter
EWS1995xxxx
xxxx declaring the primary current is absolutely necessary
Mains

4-wire
rated voltage UN
tolerance value
consumption
frequency
frequency range

Output

1 relay impulse output


relay
impulse duration
max. load
output impulse
max. impulse
EWS1195xxxx
optocoupler
impulse duration
output impulse
output impulse
impedance

photo is similar to the original

drawing

(option)
(S0)
collector open

Counter

diagram

L-N (230 V)
57 V, 100 V, 230 V, 400 V
-20 %...+20 %
< 3.0 W/phase
50 Hz
45...65 Hz

250 V, 6 A, 50 Hz
100 ms
1500 W
1 Imp/kWh
4000/h
40 V / 27 mA max.
100 ms +/-50 %
1 Imp/Wh
(30...250 A)
10 Imp/Wh
(300...2000 A)
100 Ohm

LCD counter meter for active energy import/export (kWh)


LCD counter meter
number of digits
2x9 (9.0 digits)
digit height
4.86 mm
digit width
2.96 mm

(option)
LCD counter meters for active/reactive energy (kWh/kvarh)
Current range
nominal current IN
max. current Imax
consumption
start current
nominal current IN

(option)
Primary current

EEH1985

xxxx/5 A (dip-switch setting)


5A
6A
< 0.1 W/current path
0.002 IN
xxxx/1 A
EWS1991xxxx

0.5 A to 2000 A
If not stated otherwise, the standard version 30/5 A or 30/1 A
will be supplied

Technical data

option
EWS5995xxxx
equally load phases

approbations
active energy
construction
polycarbonate housing
colour
dimensions (mm)
weight
mounting
ambient temperature operation
storage
protection class

EN 61036
class 1
acc. to UL 94 V-0
RAL 7035
106 x 90 x 58
0.3 kg
DIN rail acc. to DIN EN 50022
-10 C to +60 C
-40 C to +70 C
2

setting of the 4-pole dip switch

deviating primary currents are programmed at works


according to the details of the order.
312

www.mbs-stromwandler.de

MBS AG

EWQ1915
Three-phase energy transformer meter
AC energy transformer meter for panel board installation 96 x 96 mm
Type of energy meter
EWQ1915xxxx
xxxx declaring the primary current is absolutely necessary

drawing

Mains

4-wire
rated voltage UN
tolerance value
consumption
frequency
frequency range

L-N (230 V)
57 V, 100 V, 230 V, 400 V
-20 %...+20 %
< 3.0 W/phase
50 Hz
45...65 Hz

Output

1 relay impulse output


relay
impulse duration
max. load
output impulse
max. impulse

250 V, 6 A, 50 Hz
100 ms
1500 W
1 Imp/kWh
4000/h

Counter

1 counter meter for active


electro-mechanical meter
number of digits
digit height
digit width

Current range
diagram
(option)
Primary current

energy (kWh)
7 (7.0 digits)
4 mm
1.2 mm
xxxx/5 A
5A
6A
< 0.1 W/current path
0.002 I N
xxxx/1 A
EWQ1911xxxx

nominal current IN
max. current Imax
consumption
start current
nominal current IN

0.5 A to 2000 A
If not stated otherwise, the standard version 30/5 A or 30/1 A
will be supplied

Technical data
approbations
active energy
construction
polycarbonate housing
dimensions (mm)
weight
mounting
ambient temperature operation
storage
protection class

EN 61036
class 1
acc. to UL 94 V-0
96 x 96 x 106.8
0.6 kg
front panel
-10 C to +60 C
-40 C to +70 C
2

option
EWQ5915xxxx
equally load phases

www.mbs-stromwandler.de

313

MBS AG

EWQ1945
Three-phase energy transformer meter
AC energy transformer meter for panel board installation 96 x 96 mm
Type of energy meter
EWQ1945xxxx
xxxx declaring the primary current is absolutely necessary

drawing

Mains

4-wire
rated voltage UN
tolerance value
consumption
frequency
frequency range

L-N (230 V)
57 V, 100 V, 230 V, 400 V
-20 %...+20 %
< 3.0 W/phase
50 Hz
45...65 Hz

Output

1 relay impulse output


relay
impulse duration
max. load
output impulse
max. impulse

250 V, 6 A, 50 Hz
100 ms
1500 W
1 Imp/kWh
4000/h

Counter

2 counter meters for active energy import/export (kWh)


electro-mechanical meter
number of digits
7 (7.0 digits)
digit height
4 mm
digit width
1.2 mm

(option)
2 meters for active/reactive energy (kWh/kvarh)
Current range

diagram

(option)
Primary current

nominal current IN
max. current Imax
consumption
start current
nominal current IN

EWQ1935
xxxx/5 A
5A
6A
< 0.1 W/current path
0.002 IN
xxxx/1 A
EWQ1941xxxx

0.5 A to 2000 A
If not stated otherwise, the standard version 5 A or 1 A
will be supplied

Technical data
approbations
active energy
construction
polycarbonate housing
dimensions (mm)
weight
mounting
ambient temperature operation
storage
protection class

option
EWQ5945xxxx
equally load phases

314

www.mbs-stromwandler.de

EN 61036
class 1
acc. to UL 94 V-0
96 x 96 x 106.8
0.6 kg
front panel
-10 C to +60 C
-40 C to +70 C
2

MBS AG

EWQ1995
Three-phase energy transformer meter

AC energy transformer meter for panel board installation 96 x 96 mm


Type of energy meter
EWQ1995xxxx
xxxx declaring the primary current is absolutely necessary
Mains

4-wire
rated voltage UN
tolerance value
consumption
frequency
frequency range

L-N (230 V)
57 V, 100 V, 230 V, 400 V
-20 %...+20 %
< 3.0 W/phase
50 Hz
45...65 Hz

Output

1 relay impulse output


relay
impulse duration
max. load
output impulse
max. impulse

250 V, 6A, 50Hz


100 ms
1500 W
1 Imp/kWh
4000/h

drawing

Counter

diagram

LCD counter meter for active energy import/export (kWh)


LCD counter
number of digits
2x9 (9.0 digits)
digit height
4.86 mm
digit width
2.96 mm

(option)
LCD counter for active/reactive energy (kWh/kvarh)
Current range

(option)
Primary current

EWQ1985

xxxx/5 A
5A
6A
< 0.1 W/current path
0.002 I N
xxxx/1 A
EWQ1991xxxx

nominal current IN
max. current Imax
consumption
start current
nominal current IN

0.5 A to 2000 A
If not stated otherwise, the standard version 5 A or 1 A
will be supplied

Technical data
approbations
active energy
construction
polycarbonate housing
dimensions (mm)
weight
mounting
ambient temperature operation
storage
protection class

EN 61036
class 1
acc. to UL 94 V-0
96 x 96 x 106.8
0.6 kg
front panel
-10 C to +60 C
-40 C to +70 C
2

option
EWQ5995xxxx
equally load phases

www.mbs-stromwandler.de

315

MBS AG

MBS AG

Electro-mechanical energy meters for industrial applications


Single-phase energy meter, direct measuring
EMZ60110040
EMZ60110060

2-wire
2-wire

220 V
220 V

kWh
kWh

10 (40) A
10 (60) A

kWh
kWh
kWh
kWh
kWh
kWh

10
10
15
15
10
10

Three-phase energy meter, direct measuring


EMZ10110040
EMZ10210040
EMZ10115060
EMZ10215060
EMZ10110060
EMZ10210060

4-wire
4-wire
4-wire
4-wire
4-wire
4-wire

3x220/380
3x220/380
3x220/380
3x220/380
3x220/380
3x220/380

V
V
V
V
V
V

EMZ10120100
EMZ10125100

4-wire
4-wire

3x220/380 V
3x220/380 V

2 tariffs, HT-NT
2 tariffs, HT-NT
2 tariffs, HT-NT

(40)
(40)
(60)
(60)
(60)
(60)

A
A
A
A
A
A

kWh
kWh

20 (100) A
25 (100) A

kWh
kWh

5A
5A

Three-phase energy transformer meter


EMZ1015
EMZ1025

4-wire
4-wire

3x220/380 V
3x220/380 V

2 tariffs, HT-NT

www.mbs-stromwandler.de

317

MBS AG

MBS AG

Electronic energy meter for tariff applications


Single phase energy meter, direct measuring, clip-on onto 35 mm DIN rail
EAA7112 2-wire 1 S0-impulse output
EMU7114 2-wire 1 S0-impulse output
EMU7124 2-wire 1 S0-impulse output

2 tariffs

kWh
kWh
kWh

page
5 (32) A . . . . .320
5 (63) A . . . . .321
5 (63) A . . . . .322

Three-phase energy meter, direct measuring, clip-on onto 35 mm DIN rail


EEH4114
EEH4124
EEH4174
EEH3116
EEH3126
EEH3176
EMU4114
EMU4124
EMU4154
EMU4174
EMU4754
EMU4774
EMU4164

4-wire
4-wire
4-wire
3-wire
3-wire
3-wire
4-wire
4-wire
4-wire
4-wire
4-wire
4-wire
4-wire

1
1
1
1
1
1
1
1
1
1
1
1
1

S0-impulse
S0-impulse
S0-impulse
S0-impulse
S0-impulse
S0-impulse
S0-impulse
S0-impulse
S0-impulse
S0-impulse
S0-impulse
S0-impulse
S0-impulse

output
output
output
output
output
output
output
output
output
output
output
output
output

2 tariffs
LCD, 2 tariffs
2 tariffs
LCD, 2 tariffs
2 tariffs, HT-NT
LCD
LCD, 2 tariffs, HT-NT
LCD, M-BUS
LCD, M-BUS, 2 tariffs
LCD, 2 tariffs, HT-NT

kWh / kvarh
+/- kWh / kvarh
+/- kWh / kvarh
kWh / kvarh
+/- kWh / kvarh
+/- kWh / kvarh
kWh
kWh
kWh
kWh
kWh
kWh
kWh

10
10
10
10
10
10
5
5
5
5
5
5
5

(63)
(63)
(63)
(63)
(63)
(63)
(63)
(63)
(63)
(63)
(63)
(63)
(63)

A
A
A
A
A
A
A
A
A
A
A
A
A

.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.

.323
.324
.325
.326
.327
.328
.329
.330
.331
.332
.333
.334
.335

A,
A,
A,
A,
A,
A,

A
A
A
A
A
A
A
A
A
A
A
A
A

.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.

.
.
.
.
.
.
.
.
.
.
.
.
.

.336
.337
.338
.339
.340
.341
.342
.343
.344
.345
.346
.347
.348

Three-phase energy transformer meter, clip-on onto 35 mm DIN rail


EEH4115
EEH4125
EEH4175
EEH3115
EEH3125
EEH3175
EMU4115
EMU4125
EMU4155
EMU4175
EMU4755
EMU4775
EMU4165

4-wire
4-wire
4-wire
3-wire
3-wire
3-wire
4-wire
4-wire
4-wire
4-wire
4-wire
4-wire
4-wire

1
1
1
1
1
1
1
1
1
1
1
1
1

S0-impulse
S0-impulse
S0-impulse
S0-impulse
S0-impulse
S0-impulse
S0-impulse
S0-impulse
S0-impulse
S0-impulse
S0-impulse
S0-impulse
S0-impulse

output
output
output
output
output
output
output
output
output
output
output
output
output

2 tariffs
LCD, 2 tariffs
2 tariffs
LCD, 2 tariffs
2 tariffs, HT-NT
LCD
LCD, 2 tariffs, HT-NT
LCD, M-BUS
LCD, M-BUS, 2 tariffs
LCD, 2 tariffs, HT-NT

kWh / kvarh
+/- kWh / kvarh
+/- kWh / kvarh
kWh / kvarh
+/- kWh / kvarh
+/- kWh / kvarh
kWh
kWh
kWh
kWh
kWh
kWh
kWh

5
5
5
5
5
5

www.mbs-stromwandler.de

1
1
1
1
1
1
5
5
5
5
5
5
5

319

MBS AG

EAA7112
Single-phase energy meter
Calibrated AC energy meter for clip-on onto 35 mm DIN rail
Type of energy meter

AAD1D5F

Mains

2-wire
rated voltage UN
tolerance value:
frequency

L-N (230 V)
230 V AC, 50 Hz
-20 %...+15 %
50 Hz

Output

1 S0-impulse output
optocoupler
impulse duration
output impulse
impedance
connection terminal

5-30 V DC / 20 mA max.
50 ms
1000 Imp/kWh
100 Ohm
S0-, S0+

(S0+/S0-)
collector open
drawing

Counter

1 counter meter for active


electro-mechanical meter
number of digits:
digit height:
digit width:
function control

Current range
nominal current I N
max. current (I max)
start current
energy consumption

energy (kWh)
7 (6.1 digits)
4 mm
1.2 mm
red flashing LED 2.000 Imp/kWh
5 (32) A
5A
32 A
0.004 I N
0.4 W/current path

Technical data
approbations
accuracy class
ambient temperature
protection class
connections

PTB approval
class 1, DIN EN 61036, active energy
-10 C to +45 C
IP 50
IP 20
main connections 1...6 mm2
SO-impulse output max. 2.5 mm2
screw terminals
main connections M4,
S0 M3
Pozidrive Phillips no. 1, flat no. 1
dimensions (mm)
17.5 x 85 x 59
weight
0.08 kg
isolation characteristics
4 kV / 50 Hz, test acc. to VDE 0435
surge voltage acc. to IEC 255-4:
6 kV 1.2/50 ms
protection class 2
EMV/interference stability 4 kV 1.2/50 ms
surge voltage stability
acc. to IEC 1000-4-5 at input
1 kV 1.2/50 ms
surge voltage stability
acc. to IEC 1000-4-5 at output
SO
burst acc. to IEC 1000-4-4
level 4 (4 kV)
electro static discharge (ESD)
acc. to IEC 1000-4-2
level 3 (8 kV)

connection diagram

320

www.mbs-stromwandler.de

MBS AG

EMU7114
Single-phase energy meter

Calibrated AC energy meter for clip-on onto 35 mm DIN rail

drawing

Type of energy meter

EMU12.x1 m

Mains

2-wire
rated voltage UN
tolerance value
frequency
frequency range

L-N (230 V)
230 V
-20 %...+20 %
50 Hz
4565 Hz

Output

1 S0-impulse output
optocoupler
impulse duration
output impulse
impedance
connection terminal

5-30 V DC / 20 mA max.
125 ms
10 Imp/kWh
0.51.5 kOhm
5/6

(S0+/S0-)
collector open

Counter

1 counter meter for active energy (kWh)


1 electro-mechanical meter
number of digits
7 (6.1 digits)
digit height
4 mm
digit width
1.2 mm
operating display
green LED
LED test
10 Imp/Wh (invisible)

Current range

5 (63) A
5A
63 A
0.8 W/current path
0.005 I N

nominal current I N
max. current Imax
consumption
start current
Technical data

diagram

approbations
accuracy class
ambient temperature
protection class
connections
connections
main connection
S0-impulse output
dimensions (mm)
weight

PTB approval
class 2, DIN EN 61036, active energy
-10 C to +50 C
IP 50
IP 20
1...10 mm2
max. 2.5 mm2
36 x 90 x 71
0.15 kg

www.mbs-stromwandler.de

321

MBS AG

EMU7124
Single-phase energy meter
Calibrated AC energy meter for clip-on onto 35 mm DIN rail
Type of energy meter

EMU12.x2m

Mains

2-wire
rated voltage UN
tolerance value
frequency
frequency range

L-N (230 V)
230 V
-20 %...+20 %
50 Hz
45-65 Hz

Output

1 S0-impulse output
optocoupler
impulse duration
output impulse
impedance
connection terminal

5-30 V DC / 20 mA max.
125 ms
10 Imp/kWh
0.5 1.5 kOhm
5/6

photo is similar to the original


(S0+/S0-)
collector open
drawing
Counter

2 counter meters for active energy HT-NT (kWh)


2 electro-mechanical meters
number of digits
7 (6.1 digits)
digit height
4 mm
digit width
1.2 mm
operating display
green LED
LED test
10 Imp/Wh (invisible)

Current range
nominal current IN
max. current Imax
consumption
start current

5 (63) A
5A
63 A
0.8 W/current path
0.005 IN

Technical data
approbations
accuracy class
ambient temperature
protection class
connections
connections
main connection
SO-impulse output
dimensions (mm)
weight
tariff start
Tariff 2 is energized when
of 230 V AC
diagram

322

www.mbs-stromwandler.de

PTB approval
class 2, DIN EN 61036, active energy
-10 C to +50 C
IP 50
IP 20
1 ... 10 mm2
max. 2.5 mm2
36 x 90 x 71
0.17 kg
230 V AC
terminals 1 and 3 are under load

MBS AG

EEH4114
Three-phase energy meter
Calibrated AC energy meter for clip-on onto 35 mm DIN rail
Type of energy meter

EEH4114

Mains

4-wire
rated voltage UN
tolerance value
consumption
frequency
frequency range

L-N (230 V)
230 V
-20 %...+15 %
< 3.0 W/phase
50 Hz
45 ... 65 Hz

Output

1 S0-impulse output
optocoupler
impulse duration
output impulse
connection terminal

40 V / 27 mA max.
100 ms +/-50 %
1000 Imp/kWh
40 / 41

photo is similar to the original

(S0)
collector open

drawing

(option)
communication

RS485
connection
cable type
max. cable length
connection
isolation
transmission system
format type
transmission time
connection A and B
max. linked meters

Counter

diagram

1 counter meter for active


electro-mechanical meter
number of digits
digit height
digit width
LED test
LED operation

(option)
1 meter for reactive energy (kvarh)
Current range
nominal current IN
max. current Imax
consumption
start current

EEH4314
multi-drop
screened, wound pair
1000 m
terminal screw
3.7 kV rms for 1 min. between
all meters and other units
asynchronous
MODBUS RTU
1200 to 19200 bits/s
120 Ohm
32
energy (kWh)
7 (6.1 digits)
4 mm
1.2 mm
1000 Imp/kWh
status

(red)
(red)

EEH4104
5 (63) A
5A
63 A
< 0.02 W/current path
0.004 IN

Technical data
approbations
active energy
reactive energy
construction
housing
dimensions (mm)
weight
mounting
climatic conditions
ambient temperature operation
storage
protection class
current terminals
control terminals

PTB approval applied for


EN 61036 class 1
EN 61268 class 2
PA6.6 in conformity with UL 94 V-0
108 x 90 x 72
0.6 kg
DIN rail acc. to DIN EN 50022
EN 61036
interior meter
-20 C to +55 C
-25 C to +70 C
2
< 16 mm2
< 2.5 mm2

www.mbs-stromwandler.de

323

MBS AG

EEH4124
Three-phase energy meter
Calibrated AC energy meter for dual tariff for clip-on onto 35 mm DIN rail
Type of energy meter

EEH4124

Mains

4-wire
rated voltage UN
tolerance value
consumption
frequency
frequency range

L-N (230 V)
230 V
-20 %...+15 %
< 3.0 VA
50 Hz
45...65 Hz

Output

1 S0-impulse output
optocoupler
impulse duration
output impulse
connection terminal

40 V / 27 mA max.
100 ms +/-50 %
1000 Imp/kWh
40 / 41 / 42

photo is similar to the original

drawing

(S0)
collector open
(option)
communication

RS485
connection
cable type
max. cable length
connection
isolation
transmission system
format type
transmission time
connection A and B
max. linked meters

diagram

Counter

EEH4424
multi-drop
screened, wound pair
1000 m
terminal screw
3.7 kV rms for 1 min. between
all meters and other units
asynchronous
MODBUS RTU
1200 to 19200 bits/s
120 Ohm
32

2 counter meters for active energy HT-NT


2 electro-mechanical meters
number of digits
7 (6.1 digits)
digit height
4 mm
digit width
1.2 mm
LED test
1000 Imp/kWh
LED operation
status (tariffs)

(option)
2 meters for active/reactive energy (kvarh)
2 meters for active energy (import/export)
Current range
nominal current I N
max. current Imax
consumption
start current

(red)
(red)

EEH4234
EEH4244
5 (63) A
5A
63 A
< 0.02 VA/current path
0.004 I N

Technical data
approbations
active energy
reactive energy
construction
housing
dimensions (mm)
weight
mounting
climatic conditions
ambient temperature operation
storage
protection class
current terminals
control terminals
tariff start
Tariff 2 is energized when
of 230 V AC

324

www.mbs-stromwandler.de

PTB approval applied for


EN 61036 class 1
EN 61268 class 2
PA6.6 in conformity with UL 94 V-0
108 x 90 x 72
0.6 kg
DIN rail acc. to DIN EN 50022
EN 61036
interior meter
-20 C to +55 C
-25 C to +70 C
2
< 16 mm2
< 2.5 mm2
230 V AC
terminals 13 and 15 are under load

MBS AG

EEH4174
Three-phase energy meter
Calibrated AC energy meter for dual tariff for clip-on onto 35 mm DIN rail
Type of energy meter

EEH4174

Mains

4-wire
rated voltage UN
tolerance value
consumption
frequency
frequency range

L-N (230 V)
230 V
-20 %...+15 %
< 3.0 W/phase
50 Hz
45...65 Hz

Output

1 S0-impulse output
optocoupler
impulse duration
output impulse
connection terminal

40 V / 27 mA max.
100 ms +/-50 %
1000 Imp/kWh
40 / 41

photo is similar to the original

drawing

(S0)
collector open
(option)
communication

RS485
connection
cable type
max. cable length
connection
isolation
transmission system
format type
transmission time
connection A and B
max. linked meters

diagram

Counter

EEH4474
multi-drop
screened, wound pair
1000 m
terminal screw
3.7 kV rms for 1 min. between
all meters and other units
asynchronous
MODBUS RTU
1200 to 19200 bits/s
120 Ohm
32

LCD counter meter for active energy HT-NT (kWh)


number of digits
2 x 9 (8.1 digits)
digit height
4.86 mm
digit width
2.96 mm

(option)
2 meters for active/reactive energy (kvarh)
2 meters for active energy (import/export)
Current range

EEH4284
EEH4294
5 (63) A
5A
63 A
< 0.02 W/current path
0.004 IN

nominal current IN
max. current Imax
consumption
start current
Technical data
approbations
active energy
reactive energy
construction
housing
dimensions (mm)
weight
mounting
climatic conditions
ambient temperature operation
storage
protection class
current terminals
control terminals
tariff start
Tariff 2 is energized when
of 230 V AC

PTB approval applied for


EN 61036 class 1
EN 61268 class 2
PA6.6 in conformity with UL 94 V-0
108 x 90 x 72
0.6 kg
DIN rail acc. to DIN EN 50022
EN 61036 interior meter
-20 C to +55 C
-25 C to +70 C
2
< 16 mm2
< 2.5 mm2
230 V AC
terminals 13 and 15 are under load

www.mbs-stromwandler.de

325

MBS AG

EEH3116
Three-phase energy meter
Calibrated AC energy meter for clip-on onto 35 mm DIN rail
Type of energy meter

EEH3116

Mains

3-wire
rated voltage UN
tolerance value
consumption
frequency
frequency range

L-L (400 V)
230 V
-20 %...+15 %
< 3.0 W/phase
50 Hz
45 ... 65 Hz

Output

1 S0-impulse output
optocoupler
impulse duration
output impulse
connection terminal

40 V / 27 mA max.
100 ms +/-50 %
1000 Imp/kWh
40 / 41

photo is similar to the original

drawing

(S0)
collector open
(option)
communication

RS485
connection
cable type
max. cable length
connection
isolation
transmission system
format type
transmission time
connection A and B
max. linked meters

diagram

Counter

1 counter meter for active


electro-mechanical meter
number of digits
digit height
digit width
LED test
LED operation

(option)
1 meter for reactive energy (kvarh)
Current range
nominal current I N
max. current I max
consumption
start current

EEH3316
multi-drop
screened, wound pair
1000 m
terminal screw
3.7 kV rms for 1 min. between
all meters and other units
asynchronous
MODBUS RTU
1200 to 19200 bits/s
120 Ohm
32
energy (kWh)
7 (6.1 digits)
4 mm
1.2 mm
1000 Imp/kWh
status

(red)
(red)

EEH3106
10 (63) A
10 A
63 A
< 0.02 W/current path
0.004 I N

Technical data
approbations
active energy
reactive energy
construction
housing
dimensions (mm)
weight
mounting
climatic conditions
ambient temperature operation
storage
protection class
current terminals
control terminals

326

www.mbs-stromwandler.de

PTB approval applied for


EN 61036 class 1
EN 61268 class 2
PA6.6 in conformity with UL 94 V-0
108 x 90 x 72
0.6 kg
DIN rail acc. to DIN EN 50022
EN 61036 interior meter
-20 C to +55 C
-25 C to +70 C
2
< 16 mm2
< 2.5 mm2

MBS AG

EEH3126
Three-phase energy meter
Calibrated AC energy meter for dual tariff for clip-on onto 35 mm DIN rail
Type of energy meter

EEH3126

Mains

3-wire
rated voltage UN
tolerance value
consumption
frequency
frequency range

L-L (400)V
230 V
-20 %...+15 %
< 3.0 VA
50 Hz
45 ... 65 Hz

Output

1 S0-impulse output
optocoupler
impulse duration
output impulse
connection terminal

40 V / 27 mA max.
100 ms +/-50 %
1000 Imp/kWh
40 / 41 / 42

photo is similar to the original

drawing

(S0)
collector open
(option)
communication

RS485
connection
cable type
max. cable length
connection
isolation
transmission system
format type
transmission time
connection A and B
max. linked meters

diagram

Counter

EEH3426
multi-drop
screened, wound pair
1000 m
terminal screw
3.7 kV rms for 1 min. between
all meters and other units
asynchronous
MODBUS RTU
1200 to 19200 bits/s
120 Ohm
32

2 counter meters for active energy HT-NT (kWh)


2 electro-mechanical meters
number of digits
7 (6.1 digits)
digit height
4 mm
digit width
1.2 mm
LED test
1000 Imp/kWh
(red)
LED operation
status (tariffs)
(red)

(option)
2 meters for active/reactive energy (kvarh)
2 meters for active energy (import/export)
Current range

EEH3236
EEH3246
10 (63) A
10 A
63 A
< 0.02 VA/current path
0.004 I N

nominal current I N
max. current I max
consumption
start current
Technical data
approbations
active energy
reactive energy
construction
housing
dimensions (mm)
weight
mounting
climatic conditions
ambient temperature operation
storage
protection class 2
current terminals
control terminals
tariff start
Tariff 2 is energized when
of 230 V AC

PTB approval applied for


EN 61036 class 1
EN 61268 class 2
PA6.6 in conformity with UL 94 V-0
108 x 90 x 72
0.6 kg
DIN rail acc. to DIN EN 50022
EN 61036
interior meter
-20 C to +55 C
-25 C to +70 C
< 16 mm2
< 2.5 mm2
230 V AC
terminals 13 and 15 are under load

www.mbs-stromwandler.de

327

MBS AG

EEH3176
Three-phase energy meter
Calibrated AC energy meter for dual tariff for clip-on onto 35 mm DIN rail
Type of energy meter

EEH3176

Mains

3-wire
rated voltage UN
tolerance value
consumption
frequency
frequency range

L-L (400 V)
230 V
-20 %...+15 %
< 3.0 W/phase
50 Hz
45 ... 65 Hz

Output

1 S0-impulse output
optocoupler
impulse duration
output impulse
connection terminal

40 V / 27 mA max.
100 ms +/-50 %
1000 Imp/kWh
40 / 41

photo is similar to the original

drawing

(S0)
collector open
(option)
communication

RS485
connection
cable type
max. cable length
connection
isolation
transmission system
format type
transmission time
connection A and B
max. linked meters

diagram

Counter

EEH3476
multi-drop
screened, wound pair
1000 m
terminal screw
3.7 kV rms for 1 min. between
all meters and other units
asynchronous
MODBUS RTU
1200 to 19200 bits/s
120 Ohm
32

LCD counter meter for active energy HT-NT (kWh)


number of digits
2 x 9 (8.1 digits)
digit height
4.86 mm
digit width
2.96 mm

(option)
2 counter meters for active/reactive energy (kWh/kvarh)
2 counter meters for reactive energy (import/export) (kWh)
Current range
nominal current I N
max. current I max
consumption
start current

EEH3286
EEH3296

10 (63) A
10 A
63 A
< 0.02 W/current path
0.004 I N

Technical data
approbations
active energy
reactive energy
construction
housing
dimensions (mm)
weight
mounting
climatic conditions
ambient temperature operation
storage
protection class
current terminals
control terminals
tariff start
Tariff 2 is energized when
of 230 V AC

328

www.mbs-stromwandler.de

PTB approval applied for


EN 61036 class 1
EN 61268 class 2
PA6.6 in conformity with UL 94 V-0
108 x 90 x 72
0.6 kg
DIN rail acc. to DIN EN 50022
EN 61036 interior meter
-20 C to +55 C
-25 C to +70 C
2
< 16 mm2
< 2.5 mm2
230 V AC
terminals 13 and 15 are under load

MBS AG

EMU4114
Three-phase energy meter
Calibrated AC energy meter for clip-on onto 35 mm DIN rail
Type of energy meter

EEH4114

Mains

4-wire
rated voltage UN
tolerance value
consumption
frequency
frequency range

L-N (230 V)
230 V
-20 %...+20 %
0.8 W/current path
50 Hz
45...65 Hz

Output

1 S0-impulse output
optocoupler
impulse duration
output impulse
impedance
connection terminal

5-30 V DC / 20 mA max.
approx. 125 ms
10 Imp/kWh
0.5 1.5 kOhm
11 / 12

photo is similar to the original

drawing

(S0)
collector open

Counter

1 counter meter for active energy (kWh)


1 electro-mechanical meter
number of digits
7 (6.1 digits)
digit height
5 mm
digit width
3 mm
LED test
10 Imp/Wh
LED operation
status

Current range
nominal current I N
max. current I max
consumption
start current

diagram

(not visible)
(green)

5 (63) A
5A
63 A
0.8 W/current path
0.005 I N

Technical data
approbations
accuracy class
dimensions (mm)
weight
mounting
climatic conditions
ambient temperature operation
storage
protection class
current terminals
control terminals

PTB approval
class 2, EN 61036, active energy
107 x 90 x 71
0.35 kg
DIN rail acc. to DIN EN 50022-35
EN 61036 interior meter
-10 C to +50 C
-40 C to +70 C
2
7.6 x 8.3 mm
2.5 x 3 mm

www.mbs-stromwandler.de

329

MBS AG

EMU4124
Three-phase energy meter
Calibrated AC energy meter for dual tariff for clip-on onto 35 mm DIN rail
Type of energy meter

EMU4124

Mains

4-wire
rated voltage UN
tolerance value
consumption
frequency
frequency range

L-N (230 V)
230 V
-20 %...+20 %
0.8 W/phase
50 Hz
45 ... 65 Hz

Output

1 S0-impulse output
optocoupler
impulse duration
output impulse
impedance
connection terminal

5-30 V DC / 20 mA max.
approx. 125 ms
10 Imp/kWh
0.5 1.5 kOhm
11 / 12

photo is similar to the original

drawing

(S0)
collector open

Counter

2 counter meters for active energy HT-NT (kWh)


2 electro-mechanical meters
number of digits
7 (6.1 digits)
digit height
4 mm
digit width
1.2 mm
LED test
10 Imp/Wh
(invisible)
LED operation
status (tariffs)
(green)

Current range
nominal current I N
max. current I max
consumption
start current

diagram

5 (63) A
5A
63 A
0.8 W/current path
0.005 IN

Technical data
approbations
accuracy class
dimensions (mm)
weight
mounting
climatic conditions
ambient temperature operation
storage
protection class
current terminals
control terminals
tariff control
Tariff 2 is energized when
under load of 230 V AC

330

www.mbs-stromwandler.de

PTB approval
class 2, EN 61036, active energy
107 x 90 x 71
0.40 kg
DIN rail acc. to DIN EN 50022-35
EN 61036 interior meter
-10 C to +50 C
-40 C to +70 C
2
7.6 x 8.3 mm
2.5 x 3 mm
230 V AC
terminals 1 and 3 are

MBS AG

EMU4154
Three-phase energy meter
Calibrated AC energy meter for clip-on onto 35 mm DIN rail
Type of energy meter

EMU4154

Mains

4-wire
rated voltage UN
tolerance value
consumption
frequency
frequency range

L-N (230 V)
230 V
-20 %...+20 %
0.8 W/phase
50 Hz
45 ... 65 Hz

Output

1 S0-impulse output
optocoupler
impulse duration
output impulse
impedance
connection terminal

530 V DC / 20 mA max.
approx. 125 ms
10 Imp/kWh
0.51.5 kOhm
11 / 12

photo is similar to the original

drawing

(S0)
collector open

Counter

diagram

LCD counter meter for active energy (kWh)


LCD display
rolling display
counter indication kWh for T1 display duration
15 s
number of digits 7 (6.1 digits)
digit height
8 mm
digit width
4.5 mm
unit no.
display duration
2s
customer specific data can be
programmed at works
software version
display duration
2s
segment test
display duration
2s
energy flow
supply stopped
two-way flow
operating display
3 arrows at lower end of LCD
LED test
10 Imp/Wh
(invisible)

Current range
nominal current I N
max. current I max
consumption
start current

5 (63) A
5A
63 A
0.8 W/current path
0.005 I N

Technical data

ambient
temperature

approbations
accuracy class
dimensions (mm)
weight
mounting
climatic conditions
operation
storage
protection class
current terminals
control terminals
interface

PTB approval
class 2, EN 61036, active energy
107 x 90 x 71
0.35 kg
DIN rail acc. to DIN DIN EN 50022-35
EN 61036 interior meter
-10 C to +50 C
-40 C to +70 C
2
7.6 x 8.3 mm
2.5 x 3 mm
optical interface
acc. to IEC 61107

www.mbs-stromwandler.de

331

MBS AG

EMU4174
Three-phase energy meter
Calibrated AC energy meter for dual tariff for clip-on onto 35 mm DIN rail
Type of energy meter

EMU4174

Mains

4-wire
rated voltage UN
tolerance value
consumption
frequency
frequency range

L-N (230 V)
230 V
-20 %...+20 %
0.8 W/phase
50 Hz
45 ... 65 Hz

Output

1 S0-impulse output
optocoupler
impulse duration
output impulse
impedance
connection terminal

530 V DC / 20 mA max.
approx. 125 ms
10 Imp/kWh
0.51.5 kOhm
11 / 12

photo is similar to the original

drawing

(S0) I
collector open

Counter

diagram

LCD counter meter for active energy HT-NT (kWh)


LCD display
rolling display
counter indication kWh for T1 display duration
15 s
number of digits 7 (6.1 digits)
digit height
8 mm
digit width
4.5 mm
counter indication kWh for T2 display duration
15 s
unit no.
display duration
2s
customer specific data can be
programmed at works
software version
display duration
2s
segment test
display duration
2s
energy flow
supply stopped
two-way flow
operating display
3 arrows at lower end of LCD
LED test
10 Imp/Wh
(not visible)

Current range
nominal current IN
max. current Imax
consumption
start current

5 (63) A
5A
63 A
0.8 W/current path
0.005 I N

Technical data

ambient
temperature

332

www.mbs-stromwandler.de

approbations
accuracy class
dimensions (mm)
weight
mounting
climatic conditions
operation
storage
protection class
current terminals
control terminals
interface

PTB approval
class 2, EN 61036, active energy
107 x 90 x 71
0.35 kg
DIN rail acc. to DIN EN 50022-35
EN 61036 interior meter
-10 C to +50 C
-40 C to +70 C
2
7.6 x 8.3 mm
2.5 x 3 mm
optical interface
acc. to IEC 61107
tariff control
230 V AC
Tariff 2 is energized when terminals 1 and 3 are
under load of 230 V AC.

MBS AG

EMU4754
Three-phase energy meter M-BUS
Calibrated AC energy meter for clip-on onto 35 mm DIN rail
Type of energy meter

EMU4754

Mains

4-wire
rated voltage U N
tolerance value
consumption
frequency
frequency range

L-N (230 V)
230 V
-20 %...+20 %
0.8 W/phase
50 Hz
45 ... 65 Hz

Output

1 S0-impulse output and M-Bus output


optocoupler
5-30 V DC / 20 mA max.
impulse duration
approx. 125 ms
output impulse
10 Imp/kWh
impedance
0.5 1.5 kOhm
connection terminal
11 / 12
M-BUS data selection
current system time of the meter
operation hours of the meter
total active energy
actual active power
number of voltage interruptions
error/ flag / time indication of the
last power cut

photo is similar to the original

drawing

(S0)
collector open

Counter

diagram

LCD counter meter for active energy (kWh)


LCD display
rolling display
counter indication kWh for T1 display duration
15 s
number of digits 7 (6.1 digits)
digit height
8 mm
digit width
4.5 mm
unit no.
display duration
2s
customer specific data can be
programmed at works
software version
display duration
2s
segment test
display duration
2s
energy flow
supply stopped
two-way flow
operating display
3 arrows at lower end of LCD
LED test
10 Imp/Wh
(invisible)

Current range
nominal current IN
max. current I max
consumption
start current

5 (63) A
5A
63 A
0.8 W/current path
0.005 I N

Technical data

ambient
temperature

approbations
accuracy class
dimensions (mm)
weight
mounting
climatic conditions
operation
storage
protection class
current terminals
control terminals
interface

PTB approval, applied for active energy


class 2, EN 61036
107 x 90 x 71
0.35 kg
DIN rail acc. to DIN EN 50022-35
EN 61036 interior meter
-10 C to +50 C
-40 C to +70 C
2
7.6 x 8.3 mm
2.5 x 3 mm
optical interface
acc. to IEC 61107

www.mbs-stromwandler.de

333

MBS AG

EMU4774
Three-phase energy meter M-BUS
Calibrated AC energy meter for dual tariff for clip-on onto 35 mm DIN rail
Type of energy meter

EMU4774

Mains

4-wire
rated voltage UN
tolerance value
consumption
frequency
frequency range

L-N (230 V)
230 V
-20 %...+20 %
0.8 W/phase
50 Hz
45 ... 65 Hz

Output

1 impulse output and M-BUS output


optocoupler
5-30 V DC / 20 mA max.
impulse duration
approx. 125 ms
output impulse
10 Imp/kWh
impedance
0.5 1.5 kOhm
connection terminal
11 / 12
M-BUS data selection
current system time of the meter
operation hours of the meter
total active energy
actual active power
number of voltage interruptions
error/ flag / time indication of the
last power cut

photo is similar to the original

drawing

(S0)
collector open

Counter

diagram

LCD counter meter for active energy HT-NT (kWh)


LCD display
rolling display
counter indication kWh for T1 display duration
15 s
number of digits 7 (6.1 digits)
digit height
8 mm
digit width
4.5 mm
counter indication kWh for T2 display duration
15 s
unit no.
display duration
2s
customer specific data can be
programmed at works
software version
display duration
2s
segment test
display duration
2s
energy flow
supply stopped
two-way flow
operating display
3 arrows at lower end of LCD
LED test
10 Imp/Wh
(invisible)

Current range
nominal current I N
max. current I max
consumption
start current

5 (63) A
5A
63 A
0.8 W/current path
0.005 I N

Technical data

ambient
temperature

334

www.mbs-stromwandler.de

approbations
accuracy class
dimensions (mm)
weight
mounting
climatic conditions
operation
storage
protection class
current terminals
control terminals
interface

PTB approval, applied for active energy


class 2, EN 61036
107 x 90 x 71
0.35 kg
DIN rail acc. to DIN EN 50022-35
EN 61036 interior meter
-10 C to +50 C
-40 C to +70 C
2
7.6 x 8.3 mm
2.5 x 3 mm
optical interface
acc. to IEC 61107
tariff control
230 V AC
Tariff 2 is energized when terminals 1 and 3 are
under load of 230 V AC

MBS AG

EMU4164
Three-phase energy meter
Calibrated AC energy meter for dual tariff for clip-on onto 35 mm DIN rail
Type of energy meter

EMU4164

Mains

4-wire
rated voltage U N
tolerance value
consumption
frequency
frequency range

L-N (230 V)
230 V
-20 %...+20 %
0.8 W/phase
50 Hz
45 ... 65 Hz

Output

1 S0-impulse output
optocoupler
impulse duration
output impulse
impedance
connection terminal

5-30 V DC / 20 mA max.
ca. 125 ms
10 Imp/kWh
0.5 1.5 kOhm
11 / 12

photo is similar to the original

drawing

(S0)
collector open

Counter

LCD counter meter for active energy/active power HT-NT (kWh)


LCD display
counter (push black button to operate)
active energy (T1)
kWh, price/kWh, total price
7 (6.1) digits
4.5 x 8 mm
active energy (T2)
kWh, price/kWh
total price
present active power
kW total, kW L1-L2-L3
present voltage
V L1-L2-L3
present current
A total, A L1-L2-L3
unit no.
5 digits
LED test
10 Imp/Wh
(invisible)

Current range
nominal current I N
max. current Imax
consumption
start current

diagram

5 (63) A
5A
63 A
0.8 W/current path
0.005 I N

Technical data
approbations
accuracy class
dimensions (mm)
weight
mounting
climatic conditions
ambient temperature operation
storage
protection class
current terminals
control terminals
interface

PTB approval
class 2, EN 61036, active energy
107 x 90 x 71
0.35 kg
DIN rail acc. to DIN EN 50022-35
EN 61036 interior meter
-10 C to +50 C
-40 C to +70 C
2
7.6 x 8.3 mm
2.5 x 3 mm
optical interface
acc. to IEC 61107
tariff start
230 V AC
Tariff 2 is energized when terminals 1 and 2
are under load of 230 V AC

www.mbs-stromwandler.de

335

MBS AG

EEH4115
Three-phase energy transformer meter
Calibrated AC energy transformer meter for clip-on onto 35 mm DIN rail

photo is similar to the original

drawing

Type of energy meter


EEH4115xxxx
xxxx declaring the primary current is absolutely necessary
Mains
4-wire
L-N (230)V
rated voltage UN
230 V
tolerance value
-20 %...+15 %
consumption
< 3.0 VA
frequency
50 Hz
frequency range
45 ... 65 Hz
Output
1 S0-impulse output
optocoupler
40 V / 27 mA max.
(S0)
impulse duration
100 ms +/-50 %
collector open
output impulse
1000 Imp/kWh
connection terminal
40 / 41
(option)
communication
RS485
EEH4315xxxx
connection
multi-drop
cable type
screened, wound pair
max. cable length
1000 m
connection
terminal screw
isolation
3.7 kV rms for 1 min. between
all meters and other units
transmission system
asynchronous
format type
MODBUS RTU
transmission time
1200 to 19200 bits/s
terminal A and B
120 Ohm
max. linked meters
32
Counter

diagram

(option)

1 counter meter for active


electro-mechanical meter
number of digits
digit height
digit width
LED test
LED operation
reactive energy

Current range

(option)
Primary current

nominal current IN
max. current I max
consumption
start current
nominal current IN

energy (kWh)
7 (6.1 digits)
4 mm
1.2 mm
1000 Imp/kWh
status
EEH3105xxxx

(red)
(red)

5A
5A
6A
< 0.02 VA/current path
0.002 IN
1A
EEH3111xxxx

0.5 A up to 2000 A
If not stated otherwise, the standard version 5 A or 1 A
will be supplied

Technical data

construction

approbations
active energy
reactive energy
housing

dimensions (mm)
weight
mounting
climatic conditions
ambient temperature operation
storage
protection class
current terminals
control terminals

336

www.mbs-stromwandler.de

PTB approval applied for


EN 61036 class 1
EN 61268 class 2
PA6.6 in conformity
with UL 94 V-0
108 x 90 x 72
0.6 kg
DIN rail acc. to DIN DIN EN 50022
EN 61036 interior meter
-20 C to +55 C
-25 C to +70 C
2
< 10 mm2
< 2.5 mm2

MBS AG

EEH4125
Three-phase energy transformer meter
Calibrated AC energy transformer meter for dual tariff for clip-on onto 35 mm DIN rail

photo is similar to the original

drawing

Type of energy meter


EEH4125xxxx
xxxx declaring the primary current is absolutely necessary
Mains
4-wire
L-N (230 V)
rated voltage U N
230 V
tolerance value
-20 %...+15 %
consumption
< 3.0 W/phase
frequency
50 Hz
frequency range
45 ... 65 Hz
Output
1 S0-impulse output
optocoupler
40 V / 27 mA max.
(S0)
impulse duration
100 ms +/-50 %
collector open
output impulse
1000 Imp/kWh
connection terminal
40 / 41 / 42
(option)
communication
RS485
EEH4425xxxx
connection
multi-drop
cable type
screened, wound pair
max. cable length
1000 m
connection
terminal screw
isolation
3.7 kV rms for 1 min. between
all meters and other units
transmission system
asynchronous
format type
MODBUS RTU
transmission time
1200 to 19200 bits/s
terminal A and B
120 Ohm
max. linked meters
32
Counter

diagram

2 counters for active ernergy HT-NT (kWh)


2 electro-mechanical counters
number of digits
7 (6.1 digits)
digit height
4 mm
digit width
1.2 mm
LED test
1000 Imp/kWh
LED operation
status (tariffs)

(red)
(red)

(option)
2 counters for active and reactive energy (kWh/kvarh)
EEH4235xxxx
2 counters for active energy (import/export) (kWh)
EEH4245xxxx
Current range
5A
nominal current I N
5A
max. current I max
6A
consumption
0.02 W/current path
start current
0.002 IN
(option)
nominal current I N
1A
EEH4221xxxx
Primary current
0.5 A to 2000 A
If not stated otherwise, the standard version 5 A or 1 A
will be supplied.
Technical data
approbations
PTB approval applied for
active energy
EN 61036 class 1
reactive energy
EN 61268 class 2
construction
housing
PA6.6 in conformity
with UL 94 V-0
dimensions (mm)
108 x 90 x 72
weight
0.6 kg
mounting
DIN rail acc. to DIN EN 50022
climatic conditions
EN 61036 interior meter
ambient temperature operation
-20 C to +55 C
storage
-25 C to +70 C
protection class
2
current terminals
< 10 mm2
control terminals
< 2.5 mm2
tariff start
230 V AC
Tariff 2 is energized when terminals 13 and 15 are
under load of 230 V AC.
www.mbs-stromwandler.de

337

MBS AG

EEH4175
Three-phase energy transformer meter
Calibrated AC energy transformer meter for clip-on onto 35 mm DIN rail

photo is similar to the original

drawing

Type of energy meter


EEH4175xxxx
xxxx declaring the primary current is absolutely necessary
Mains
4-wire
L-N (230 V)
rated voltage Uv
230 V
tolerance value
-20 %...+15 %
consumption
< 3.0 W
frequency
50 Hz
frequency range
45...65 Hz
Output
1 S0-impulse output
optocoupler
40 V / 27 mA max.
(S0) I
impulse duration
100 ms +/-50 %
collector open
output impulse
1000 Imp/kWh
connection terminal
40 / 41
(option)
communication
RS485
EEH4475xxxx
connection
multi-drop
cable type
screened, wound pair
max. cable length
1000 m
connection
terminal screw
isolation
3.7 kV rms for 1 min. between
all meters and other units
transmission system
asynchronous
format type
MODBUS RTU
transmission time
1200 to 19200 bits/s
terminal A and B
120 Ohm
max. linked meters
32
Counter

diagram

LCD counter meter for active energy HT-NT (kWh)


number of digits
2 x 9 (8.1 digits)
digit height
4.86 mm
digit width
2.96 mm

(option)
2 counters for active and reactive energy (kWh/kvarh)
2 counters for active energy (import/export) (kWh)
Current range

(option)
Primary current

nominal current I N
max. current Imax
consumption
start current
nominal current I N

EEH4285xxxx
EEH4295xxxx

5A
5A
6A
< 0.02 W/current path
0.002 IN
1A
EEH4271xxxx

0.5 A up to 2000 A
If not stated otherwise, the standard version 5 A or 1 A
will be supplied

Technical data
approbations
active energy
reactive energy
construction
housing
dimensions (mm)
weight
mounting
climatic conditions
ambient temperature operation
storage
protection class
current terminals
control terminals
tariff start
Tariff 2 is energized when
under load of 230 V AC.

338

www.mbs-stromwandler.de

PTB approval applied for


EN 61036 class 1
EN 61268 class 2
PA6.6 in conformity with UL 94 V-0
108 x 90 x 72
0.6 kg
DIN rail acc. to DIN EN 50022
EN 61036 interior meter
-20 C to +55 C
-25 C to +70 C
2
< 10 mm2
< 2.5 mm2
230 V AC
terminals 13 and 15 are

MBS AG

EEH3115
Three-phase energy transformer meter
Calibrated AC energy transformer meter for clip-on onto 35 mm DIN rail

photo is similar to the original

drawing

Type of energy meter


EEH3115xxxx
xxxx declaring the primary current is absolutely necessary
Mains
3-wire
L-L (400 V)
rated voltage UN
230 V
tolerance value
-20 %...+15 %
consumption
< 3.0 W/phase
frequency
50 Hz
frequency range
45 ... 65 Hz
Output
1 S0-impulse output
optocoupler
40 V / 27 mA max.
(S0)
impulse duration
100 ms +/-50 %
collector open
output impulse
1000 Imp/kWh
connection terminal
40 / 41
(option)
communication
RS485
EEH3315xxxx
connection
multi-drop
cable type
screened, wound pair
max. cable length
1000 m
connection
terminal screw
isolation
3.7 kV rms for 1 min. between
all meters and other units
transmission system
asynchronous
format type
MODBUS RTU
transmission time
1200 to 19200 bits/s
terminal A and B
120 Ohm
max. linked meters
32
Counter

diagram

(option)

1 counter meter for active


electro-mechanical meter
number of digits
digit height
digit width
LED test
LED operation
reactive energy (kvarh)

Current range

(option)
Primary current

nominal current I N
max. current Imax
consumption
start current
nominal current I N

energy (kWh)
7 (6.1 digits)
4 mm
1.2 mm
1000 Imp/kWh
status

(red)
(red)
EEH3105xxxx

5A
5A
6A
< 0.02 W/current path
0.002 IN
1A
EEH3111xxxx

0.5 A up to 2000 A
If not stated otherwise, the standard version 5 A or 1 A
will be supplied.

Technical data
approbations
active energy
reactive energy
construction
housing
dimensions (mm)
weight
mounting
climatic conditions
ambient temperature operation
storage
protection class
current terminals
control terminals

PTB approval applied for


EN 61036 class 1
EN 61268 class 2
PA6.6 in conformity with UL 94 V-0
108 x 90 x 72
0.6 kg
DIN rail acc. to DIN EN 50022
EN 61036 interior meter
-20 C to +55 C
-25 C to +70 C
2
< 10 mm2
< 2.5 mm2

www.mbs-stromwandler.de

339

MBS AG

EEH3125
Three-phase energy transformer meter
Calibrated AC energy transformer meter for dual tariff for clip-on onto 35 mm DIN rail

photo is similar to the original

drawing

Type of energy meter


EEH3125xxxx
xxxx declaring the primary current is absolutely necessary
Mains
3-wire
L-L (400 V)
rated voltage UN
230 V
tolerance value
-20 %...+15 %
consumption
< 3.0 W/phase
frequency
50 Hz
frequency range
45 ... 65 Hz
Output
1 S0-impulse output
optocoupler
40 V / 27 mA max.
(S0)
impulse duration
100 ms +/-50 %
collector open
output impulse
1000 Imp/kWh
connection terminal
40 / 41 / 42
(option)
communication
RS485
EEH3425xxxx
connection
multi-drop
cable type
screened, wound pair
max. cable length
1000 m
connection
terminal screw
isolation
3.7 kV rms for 1 min. between
all meters and other units
transmission system
asynchronous
format type
MODBUS RTU
transmission time
1200 to 19200 bits/s
terminal A and B
120 Ohm
max. linked meters
32
Counter

diagram

2 counters for active energy HT-NT (kWh)


2 electro-mechanical counters
number of digits
7 (6.1 digits)
digit height
4 mm
digit width
1.2 mm
LED test
1000 Imp/kWh
LED operation
status (tariffs)

(red)
(red)

(option)
2 counters for active and reactive energy (kWh/kvarh
EEH3225xxxx
2 counters for active energy (import/export) (kWh)
EEH3245xxxx
Current range
5A
nominal current I N
5A
max. current I max
6A
consumption
< 0.02 W/current path
start current
0.002 IN
(option)
nominal current I N
1A
EEH3221xxxx
Primary current
0.5 A to 2000 A
If not stated otherwise, the standard version 5 A or 1 A
will be supplied.
Technical data
approbations
PTB approval applied for
active energy
EN 61036 class 1
reactive energy
EN 61268 class 2
construction
housing
PA6,6 in conformity with UL 94 V-0
dimensions (mm)
108 x 90 x 72
weight
0.6 kg
mounting
DIN rail acc. to DIN EN 50022
climatic conditions
EN 61036 interior meter
ambient temperature operation
-20 C to +55 C
storage
-25 C to +70 C
protection class
2
current terminals
< 10 mm2
control terminals
< 2.5 mm2
tariff start
230 V AC
Tariff 2 is energized when terminal 13 and 15
are under load of 230 V AC

340

www.mbs-stromwandler.de

MBS AG

EEH3175
Three-phase energy transformer meter
Calibrated AC energy transformer meter for dual tariff for clip-on onto 35 mm DIN rail

photo is similar to the original

drawing

Type of energy meter


EEH3175xxxx
xxxx declaring the primary current is absolutely necessary
Mains
3-wire
L-L (400 V)
rated voltage U N
230 V
tolerance value
-20 %...+15 %
consumption
< 3.0 W
frequency
50 Hz
frequency range
45 ... 65 Hz
Output
1 S0-impulse output
optocoupler
40 V / 27 mA max.
(S0)
impulse duration
100 ms +/-50 %
collector open
output impulse
1000 Imp/kWh
connection terminal
40 / 41
(option)
communication
RS485
EEH3475xxxx
connection
multi-drop
cable type
screened, wound pair
max. cable length
1000 m
connection
terminal screw
isolation
3.7 kV rms for 1 min. between
all meters and other units
transmission system
asynchronous
format type
MODBUS RTU
transmission time
1200 to 19200 bits/s
terminal A and B
120 Ohm
max. linked meters
32
Counter

diagram

LCD counter meter for active energy HT-NT (kWh)


number of digits
2 x 9 (8.1 digits)
digit height
4.86 mm
digit width
2.96 mm

(option)
2 counters for active and reactive energy (kWh/kvarh)
EEH3285xxxx
2 counters for active energy (import/export) (kWh)
EEH3295xxxx
Current range
5A
nominal current I N
5A
max. current I max
6A
consumption
< 0.02 W/current path
start current
0.002 IN
(option)
nominal current I N
1A
EEH3271xxxx
Primary current
0.5 A up to 2000 A
If not stated otherwise, the standard version 5 A or 1 A
will be supplied.
Technical data
approbations
PTB approval applied for
active energy
EN 61036 class 1
reactive energy
EN 61268 class 2
construction
housing
PA6.6 in conformity with UL 94 V-0
dimensions (mm)
108 x 90 x 72
weight
0.6 kg
mounting
DIN rail acc. to DIN EN 50022
climatic conditions
EN 61036 interior meter
ambient temperature operation
-20 C to +55 C
storage
-25 C to +70 C
protection class
2
current terminals
< 10 mm2
control terminals
< 2.5 mm2
tariff start
230 V AC
Tariff 2 is energized when terminal 13 and 15 are
under load of 230 V AC

www.mbs-stromwandler.de

341

MBS AG

EMU4115
Three-phase energy transformer meter
Calibrated AC energy transformer meter for clip-on onto 35 mm DIN rail
Type of energy meter
EMU4115xxxx
xxxx declaring the primary current is absolutely necessary
Mains

4-wire
rated voltage UN
tolerance value
consumption
frequency
frequency range

Output

1 S0-impulse output
optocoupler
impulse duration
output impulse

photo is similar to the original

drawing

(S0)
collector open

impedance
connection terminal
Counter
diagram

nominal current I N
max. current Imax
consumption
start current
Primary current

530 V DC / 20 mA max.
approx. 125 ms
10 Imp/kWh 0.5 A to 250 A
1 Imp/kWh 400 A to 2500 A
0.51.5 kOhm
11 / 12

1 counter meter for active energy (kWh)


1 electro-mechanical counter
number of digits
7 (6.1 digits) 0.5 A up to 250 A
7 (7.0 digits) 400 A up to 2500 A
digit height
5 mm
digit width
3 mm
LED test
10 Imp/Wh
(invisible)
LED operation
status
(green)

Current range

table1 1
table

L-N (230 V)
230 V
-20 %...+20 %
0.8 W/phase
50 Hz
45 ... 65 Hz

5A
5A
6A
0.8 W/current path
0.002 I N

0.5 A up to 2000 A
If not stated otherwise, the standard version 5 A will be supplied.

Technical data
approbations
accuracy class
dimensions (mm)
weight
mounting
climatic conditions
ambient temperature operation
storage
protection class
current terminals
control terminals
table2 2
table

342

www.mbs-stromwandler.de

PTB approval
class 1, EN 61036, active energy
107 x 90 x 71
0.35 kg
DIN rail acc. to DIN EN 50022-35
EN 61036 interior meter
-10 C to +50 C
-40 C to +70 C
2
4.2 x 6.5 mm
2.5 x 3 mm

MBS AG

EMU4125
Three-phase energy transformer meter
Calibrated AC energy transformer meter for dual tariff for clip-on onto 35 mm DIN rail
Type of energy meter
EMU4125xxxx
xxxx declaring the primary current is absolutely necessary
Mains

4-wire
rated voltage UN
tolerance value
consumption
frequency
frequency range

Output

1 S0-impulse output
optocoupler
impulse duration
output impulse

photo is similar to the original


diagram

(S0)
collector open

L-N (230 V)
230 V
-20 %...+20 %
0.8 W/phase
50 Hz
45 ... 65 Hz

impedance
connection terminal
drawing

Counter

2 counters for active energy HT-NT (kWh)


2 electro-mechanical meters
number of digits
7 (6.1 digits)
number of digits
7 (7.0 digits)
digit height
4 mm
digit width
1.2 mm
LED test
10 Imp/Wh
LED operations
status (tariffs)

Current range

Primary current

0.5 A up to 250 A
400 A up to 2500 A

(invisible)
(green)

5A
5A
6A
0.8 W/current path
0.002 I N

nominal current I N
max. current Imax
consumption
start current
table 1

5-30 V DC / 20 mA max.
approx. 125 ms
10 Imp/kWh
0.5 A up to 250 A
1 Imp/kWh
400 A up to 2500 A
0.5 1.5 kOhm
11 / 12

0.5 A up to 2000 A
If not stated otherwise, the standard version 5 A will be supplied.

Technical data

table 2

approbations
accuracy class
dimensions (mm)
weight
mounting
climatic conditions
ambient temperature operation
storage
protection class
current terminals
control terminals
tariff start
Tariff 2 is energized when
under load of 230 V AC.

PTB approval
class 1, EN 61036, active energy
107 x 90 x 71
0.35 kg
DIN rail acc. to DIN EN 50022-35
EN 61036 interior meter
-10 C to +50 C
-40 C to +70 C
2
4.2 x 6.5 mm
2.5 x 3 mm
230 V AC
terminals 1 and 3 are

www.mbs-stromwandler.de

343

MBS AG

EMU4155
Three-phase energy transformer meter
Calibrated AC energy transformer meter for clip-on onto 35 mm DIN rail
Type of energy meter

EMU4155

Mains

4-wire
rated voltage UN
tolerance value
consumption
frequency
frequency range

L-N (230 V)
230 V
-20 %...+20 %
0.8 W/phase
50 Hz
45 ... 65 Hz

Output

1 S0-impulse output
optocoupler
impulse duration
output impulse
impedance
connection terminal

5-30 V DC / 20 mA max.
approx. 20 ms
1000 Imp/kWh
0.5 1.5 kOhm
11 / 12

photo is similar to the original

drawing

(S0)
collector open

Counter

diagram

LCD-counter meter for active energy (kWh)


LCD display
rolling counter
counter indication kWh for T1 display duration
15 s
number of digits 7 (6.1 digits)
digit height
8 mm
digit width
4.5 mm
unit no.
display duration
2s
customer specific data can be
programmed at works
software version
display duration
2s
segment test
display duration
2s
energy flow
supply stopped
two-way flow
operating display
3 arrows at lower end of LCD
LED test
10 Imp/Wh
(invisible)

Current range
nominal current I N
max. current Imax
consumption
start current

5A
5A
6A
0.8 W/current path
0.002 I N

Technical data

ambient
temperature

344

www.mbs-stromwandler.de

approbations
accuracy class
dimensions (mm)
weight
mounting
climatic conditions
operation
storage
protection class
current terminals
control terminals
interface

PTB approval applied for active energy


class 1, EN 61036
107 x 90 x 71
0.35 kg
DIN rail acc. to DIN EN 50022-35
EN 61036 interior meter
-10 C to +50 C
-40 C to +70 C
2
4.2 x 6.5 mm
2.5 x 3 mm
optical interface
acc. to IEC 61107

MBS AG

EMU4175
Three-phase energy transformer meter
Calibrated AC energy transformer meter for dual tariff for clip-on onto 35 mm DIN rail
Type of energy meter

EMU4175

Mains

4-wire
rated voltage UN
tolerance value
consumption
frequency
frequency range

L-N (230 V)
230 V
-20 %...+20 %
0.8 W/phase
50 Hz
45 ... 65 Hz

Output

1 S0-impulse output
optocoupler
impulse duration
output impulse
impedance
connection terminal

5-30 V DC / 20 mA max.
approx. 20 ms
1000 Imp/kWh
0.51.5 kOhm
11 / 12

photo is similar to the original

drawing

(S0)
collector open

Counter

diagram

LCD counter meter for active energy HT-NT (kWh)


LCD display
rolling counter
counter indication kWh for T1 display duration
15 s
number of digits 7 (6.1 digits)
digit height
8 mm
digit width
4.5 mm
counter indication kWh for T2 display duration
15 s
unit no.
display duration
2s
customer specific data can be
programmed at works
software version
display duration
2s
segment test
display duration
2s
energy flow
supply stopped
two-way flow
operating display
3 arrows at lower end of LCD
LED test
10 Imp/Wh
(invisible)

Current range
nominal current I N
max. current Imax
consumption
start current

5A
5A
6A
0.8 W/current path
0.002 I N

Technical data

ambient
temperature

approbations
accuracy class
dimensions (mm)
weight
mounting
climatic conditions
operation
storage
protection class
current terminals
control terminals
interface

PTB approval applied for active energy


class 1, EN 61036
107 x 90 x 71
0.35 kg
DIN rail acc. to DIN EN 50022-35
EN 61036 interior meter
-10 C to +50 C
-40 C to +70 C
2
4.2 x 6.5 mm
2.5 x 3 mm
optical interface
acc. to IEC 61107
tariff start
230 V AC
Tariff 2 is energized when terminals 1 and 3
are under load of 230 V AC

www.mbs-stromwandler.de

345

MBS AG

EMU4755
Three-phase energy transformer meter M-BUS
Calibrated AC energy transformer meter for clip-on onto 35 mm DIN rail
Type of energy meter

EMU4755

Mains

4-wire
rated voltage UN
tolerance value
consumption
frequency
frequency range

L-N (230 V)
230 V
-20 %...+20 %
0.8 VA
50 Hz
45 ... 65 Hz

Output

1 impulse output and M-BUS output


optocoupler
5-30 V DC / 20 mA max.
impulse duration
ca. 20 ms
output impulse
1000 Imp/kWh
impedance
0.5 1.5 kOhm
connection terminal
11 / 12
M-BUS data selection
current system time of the meter
operation hours of the meter
total active energy
actual active power
number of voltage interruptions
error flag/ time indication of the
last power cut

photo is similar to the original

drawing

(S0)
collector open

Counter

diagram

LCD counter meter for active energy (kWh)


LCD display
rolling counter
counter indication kWh for T1 display duration
15 s
number of digits 7 (6.1 digits)
digit height
8 mm
digit width
4.5 mm
unit no.
display duration
2s
customer specific data can be
programmed at works
software version
display duration
2s
segment test
display duration
2s
energy flow
supply stopped
two-way flow
operating display
3 arrows at lower end of LCD
LED test
10 Imp/Wh
(invisible)

Current range
nominal current I N
max. current I max
consumption
start current

5A
5A
6A
0.8 W/current path
0.002 I N

Technical data

ambient
temperature

346

www.mbs-stromwandler.de

approbations
accuracy class
dimensions (mm)
weight
mounting
climatic conditions
operation
storage
protection class
current terminals
control terminals
interface

PTB approval applied for active energy


class 1, EN 61036
107 x 90 x 71
0.35 kg
DIN rail acc. to DIN EN 50022-35
EN 61036 interior meter
-10 C to +50 C
-40 C to +70 C
2
4.2 x 6.5 mm
2.5 x 3 mm
optical interface
acc. to IEC 61107

MBS AG

EMU4775
Three-phase energy transformer meter M-BUS
Calibrated AC energy transformer meter for dual tariff for clip-on onto 35 mm DIN rail
Type of energy meter

EMU4775

Mains

4-wire
rated voltage UN
tolerance value
consumption
frequency
frequency range

L-N (230 V)
230 V
-20 %...+20 %
0.8 W/phase
50 Hz
45 ... 65 Hz

Output

1 impulse output and M-BUS output


optocoupler
5-30 V DC / 20 mA max.
impulse duration
approx. 20 ms
output impulse
1000 Imp/kWh
impedance
0.5 1.5 kOhm
connection terminal
11 / 12
M-BUS data selection
current system time of the meter
operation hours of the meter
total active energy
actual active power
number of voltage interruptions
error flags/time indication of the
last power cut

photo is similar to the original

drawing

(S0)
collector open

Counter

diagram

LCD counter meter for active energy HT-NT (kWh)


LCD display
rolling counter
counter indication kWh for T1 display duration
15 s
number of digits 7 (6.1 digits)
digit height
8 mm
digit width
4.5 mm
counter indication kWh for T2 display duration
15 s
unit no.
display duration
2s
customer specific data can be
programmed at works
software version
display duration 2 s
segment test
display duration 2 s
energy flow
supply stopped two-way flow
operating display
3 arrows at lower end of LCD
LED test
10 Imp/Wh
(invisible)

Current range
nominal current I N
max. current I max
consumption
start current

5A
5A
6A
0.8 W/current path
0.002 I N

Technical data

ambient
temperature

approbations
PTB approval applied for active energy
accuracy class
class 1, EN 61036
dimensions (mm)
107 x 90 x 71
weight
0.35 kg
mounting
DIN rail acc. to DIN EN 50022-35
climatic conditions
EN 61036 interior meter
operation
-10 C to +50 C
storage
-40 C to +70 C
protection class
2
current terminals
4.2 x 6.5 mm
control terminals
2.5 x 3 mm
interface
optical interface acc. to IEC 61107
tariff start
230 V AC
Tariff is energized when terminals 1 and 3 are
under load of 230 V AC

www.mbs-stromwandler.de

347

MBS AG

EMU4165
Three-phase energy transformer meter
Calibrated AC energy transformer meter for dual tariff for clip-on onto 35 mm DIN rail
Type of energy meter
EMU4165xxxx
xxxx declaring the primary current is absolutely necessary
Mains

4-wire
rated voltage UN
tolerance value
consumption
frequency
frequency range

L-N (230 V)
230 V
-20 %...+20 %
0.8 W/phase
50 Hz
45 ... 65 Hz

Output

1 S0-impulse output
optocoupler
impulse duration
output impulse
impedance
connection terminal

5-30 V DC / 20 mA max.
approx. 125 ms
10 Imp/kWh
0.5 1.5 kOhm
11 / 12

photo is similar to the original

drawing
(S0)
collector open

Counter

diagram

LCD counter meter for active energy/active power HT-NT (kWh)


LCD display
counter (push black button to operate)
active energy (T1)
kWh, price/kWh, total price
7 (6.1) digits
4.5 x 8 mm
active energy (T2)
kWh, price/kWh total price
present active power
kW total, kW L1-L2-L3
present voltage
V L1-L2-L3
present current
A total, A L1-L2-L3
current transformer factor FA e.g. 100A, FA 20 (100/5)
unit no.
5 digits
LED test
10 Imp/Wh
(invisible)

Current range
nominal current IN
max. current I max
consumption
start current
Primary current

5A
5A
6A
0.8 W/current path
0.002 IN

5 A up to 1275 A
If not stated otherwise, the standard version of 5 A
will be supplied.

Technical data
approbations
accuracy class
dimensions (mm)
weight
mounting
climatic conditions
ambient temperature operation
storage
protection class
current terminals
control terminals
interface

PTB approval
class 1, EN 61036, active energy
107 x 90 x 71
0.35 kg
DIN rail acc. to DIN EN 50022-35
EN 61036 interior meter
-10 C to +50 C
-40 C to +70 C
2
4.2 x 6.5 mm
2.5 x 3 mm
optical interface
acc. to IEC 61107
tariff start
230 V AC
Tariff 2 is energized when terminals 1 and 3 are
under load of 230 V AC

348

www.mbs-stromwandler.de

MBS AG

Electro-mechanical energy meter for tariff applications


Single-phase energy meter, direct measuring
EMZ70110040
EMZ70110060

2-wire
2-wire

230 V
230 V

kWh
kWh

10 (40) A
10 (60) A

kWh
kWh
kWh
kWh
kWh
kWh

10
10
15
15
10
10

Three-phase energy meter, direct measuring


EMZ40110040
EMZ40210040
EMZ40115060
EMZ40215060
EMZ40110060
EMZ40210060

4-wire
4-wire
4-wire
4-wire
4-wire
4-wire

3x230/400
3x230/400
3x230/400
3x230/400
3x230/400
3x230/400

V
V
V
V
V
V

2 tariffs, HT-NT
2 tariffs, HT-NT
2 tariffs, HT-NT

(40)
(40)
(60)
(60)
(60)
(60)

A
A
A
A
A
A

Electronic three-phase energy meter, direct measuring for three point counter
mounting
EMZ40120100
EMZ40125100

4-wire
4-wire

3x230/400 V
3x230/400 V

kWh
kWh

20 (100) A
25 (100) A

kWh
kWh

5A
5A

Three-phase energy transformer meter


EMZ4015
EMZ4025

4-wire
4-wire

3x230/400 V
3x230/400 V

2 tariffs, HT-NT

www.mbs-stromwandler.de

349

MBS AG

Code
Code
Type of energy meter
AAD1D5F
ECP***
EM1000
EMU****
EMU****
EEH****
EMU****
WS****
WQ****
Electro mechanical meter
Mains
4-wire
3-wire
4-wire (calibrated)
3-wire (calibrated)
4-wire (equally loaded phases)
2-wire
2-wire (calibrated)
3-wire (equally loaded phases)
special configurations upon request
Output
without S0-Impulse output
1 S0-impulse output
2 S0-impulse outputs
1 impulse output and RS485 output
2 S0-impulse outputs and RS485 output
cable connection
socket
1 impulse output and M-BUS output
1 relay impulse output (only for EWS****, EWQ****)
Counter
1 counter for reactive energy
1 counter for active energy
2 counters for active energy HT-NT
2 counters for active and reactive energy
2 counters for active energy import/export
LCD counter for active energy
LCD counter for active energy/active power HT-NT
LCD counter for active energy HT-NT
LCD counter for active and reactive energy
LCD counter for active energy import/export
Current range
1A
5 (32) A
26 (30) A
5 (63) A
5A
10 (30) A
10 (40) A
15 (60) A
10 (60) A
10 (100) A
10 (63) A
16 A
Primary current (only for current transformer meters)
Example: Secondary 1 A, primary 125 A

350

www.mbs-stromwandler.de

L-N
L-L
L-N
L-L
L-N
L-N
L-N
L-L

(230
(400
(230
(400
(230
(230
(230
(400

V)
V)
V)
V)
V)
V)
V)
V)

E A
E C
E E
E M
E M
E E
E M
E W
E W
E M

A
P
M
U
U
H
U
S
Q
Z

article no.
* * * X

X X X

1
2
4
3
5
6
7
8
9
0
1
2
3
4
5
6
7
9

(kvarh)
(kWh)
(kWh)
(kWh)/(kvarh)
(kWh)
(kWh)
(kWh)/(kW)
(kWh)
(kWh)/(kvarh)
(kWh)

0
1
2
3
4
5
6
7
8
9
1
2
3
4
5
1
1
1
1
1
6
7
1

0
0
5
0
0

0
0
0
0
1

3
4
6
6
0

0
0
0
0
0

x
0

x
1

x x
2 5

MBS AG

Notes

www.mbs-stromwandler.de

351

MBS AG

10 reasons to be associated
with products from MBS
customer oriented solutions
individual consultancy
satisfied customers in all continents
a product range in excess of 20000 units
supreme technical quality
a multiple of international licences and certificates,
DIN EN ISO 9001-2000
official calibration of current transformers and measuring units
relialibility
fast deliveries
30 years of success

352

www.mbs-stromwandler.de

You might also like