RNC Basic Commands
RNC Basic Commands
MSS POOLING,
--HOW TO CHECK THE MSS is in POLLING FROM NSS END?
A) ZE3I:TYPE=PAR;
found mss name and NRI VALUES under pooling.
SAME VALUES MUST BE IN IUCS RNW OBJECT BROWSER IF IUCS IN POOLING.
--how to check what are the sites are connected to particular icsu
ZDDS;
CREATE RNW MISC UTILITIES
ZLE:1,RUOSTEQX
1
I:icsu-no;
Interrogate IP addresses e.g. in the NPGE units is done using MML command is ZQRI. The IU-PS
user plane address 10.131.0.62/32 in NPGEP 0 in the example
ZQRI:NPGEP,0;
O/P
VL102 10.131.0.62/32.
Interrogating VLANs
You can interrogate a VLAN interface with commands QRE. NPGE(P) is the only unit to support VLAN
interface. VLAN can be created using command
ZQRE:NPGEP,0;
ZOYI::A;
Interrogate source IP addresses for ICSUS
ZOYL;
Interrogating Parameter SET Data.
ZOYO;
ZOYS:M3UA:IUPS,0:ACT:;