User Manual

UPS EPSILON

On-line Double Conversion 1K/2K/3K

Uninterruptible Power Supply System

www.qbex.com

Table of Contents
1. Important Safety Warning 4




1-1. Transportation..........................................................................................
1-2. Preparation..............................................................................................
1-3. Installation................................................................................................
1-4. Operation.................................................................................................
1-5. Maintenance, service and faults..............................................................

4
4
4
5
5

2. Installation and setup...... 6



2-1. Rear panel view....................................................................................... 6


2-2. Setup the UPS......................................................................................... 9

3. Operations....... 8







3-1. Button operation...................................................................................... 12


3-2. LCD Panel............................................................................................... 13
3-3. Audible Alarm........................................................................................... 14
3-4. LCD display wordings index.................................................................... 15
3-5. UPS Setting............................................................................................. 15
3-6. Operating Mode Description.................................................................... 19
3-7. Faults Reference Code............................................................................ 20
3-8. Warning indicator..................................................................................... 20

4. Troubleshooting... 21
5. Storage and Maintenance 22
6. Specifications.. 23

1-4. Operation

Please comply with all warnings and operating instructions in this manual strictly. Save this manual properly and
read carefully the following instructions before installing the unit. Do not operate this unit before reading through
all safety information and operating instructions carefully.

Do not disconnect the mains cable on the UPS system or the building wiring outlet
(shockproof socket outlet) during operations since this would cancel the protective earthing of the
UPS system and of all connected loads.

1-1. Transportation

The UPS system features its own, internal current source (batteries). The UPS output sockets
or output terminals block may be electrically live even if the UPS system is not connected to the
building wiring outlet.

In order to fully disconnect the UPS system, first press the OFF/Enter button to disconnect the
mains.

Prevent no fluids or other foreign objects from inside of the UPS system.

Please transport the UPS system only in the original package to protect against shock and impact.

1-2. Preparation



Condensation may occur if the UPS system is moved directly from cold to warm environment. The UPS
system must be absolutely dry before being installed. Please allow at least two hours for the UPS system to
acclimate the environment.

Do not install the UPS system near water or in moist environments.

Do not install the UPS system where it would be exposed to direct sunlight or near heater.

Do not block ventilation holes in the UPS housing.

1-3. Installation

Do not connect appliances or devices which would overload the UPS system (e.g. laser printers) to the UPS
output sockets.

Place cables in such a way that no one can step on or trip over them.

Do not connect domestic appliances such as hair dryers to UPS output sockets.

The UPS can be operated by any individuals with no previous experience.

Connect the UPS system only to an earthed shockproof outlet which must be easily accessible and close to
the UPS system.

Please use only VDE-tested, CE-marked mains cable (e.g. the mains cable of your computer) to connect the
UPS system to the building wiring outlet (shockproof outlet).

Please use only VDE-tested, CE-marked power cables to connect the loads to the UPS system.

When installing the equipment, it should ensure that the sum of the leakage current of the UPS and the con
nected devices does not exceed 3.5mA.

EPSILON 1K /2K/3K On line UPS

UPS

1. Important Safety Warning

1-5. Maintenance, service and faults













The UPS system operates with hazardous voltages. Repairs may be carried out only by qualified
maintenance personnel.

Caution - risk of electric shock. Even after the unit is disconnected from the mains (building wiring outlet),
components inside the UPS system are still connected to the battery and electrically live and dangerous.
Before carrying out any kind of service and/or maintenance, disconnect the batteries and verify that no
current is present and no hazardous voltage exists in the terminals of high capability capacitor such as
BUS-capacitors.
Only persons are adequately familiar with batteries and with the required precautionary measures may
replace batteries and supervise operations. Unauthorized persons must be kept well away from the batteries.


Caution - risk of electric shock. The battery circuit is not isolated from the input voltage. Hazardous voltages

may occur between the battery terminals and the ground. Before touching, please verify that no voltage is

present!


Batteries may cause electric shock and have a high short-circuit current. Please take the precautionary

measures specified below and any other measures necessary when working with batteries:

Remove wristwatches, rings and other metal objects

use only tools with insulated grips and handles.


When changing batteries, install the same number and same type of batteries.


Do not attempt to dispose of batteries by burning them. This could cause battery explosion.


Do not open or destroy batteries. Escaping electrolyte can cause injury to the skin and eyes. It may be toxic.


Please replace the fuse only with the same type and amperage in order to avoid fire hazards.


Do not dismantle the UPS system.

EPSILON 1K /2K/3K On line UPS

2. Installation and setup

UPS

NOTE: Before installation, please inspect the unit. Be sure that nothing inside the package is damaged. Please
keep the original package in a safe place for future use.

2K(L) TOWER

NOTE: There are two different types of online UPS: standard and long-run models. Please refer to the following
model table.

Model
1K
2K
3K

Type
Standard

Model
1KL
2KL
3KL

Type
Long-run

IEC Tipo

2-1. Rear panel view


1K (L) TOWER

3K(L) TOWER

IEC Tipo

NEMA Tipo

EPSILON 1K /2K/3K On line UPS

NEMA Tipo

IEC Tipo

NEMA Tipo

EPSILON 1K /2K/3K On line UPS

1K(L) RACK

NEMA Tipo

2K(L) RACK

Programmable outlets: connect to non-critical loads.

Output receptacles: connect to mission-critical loads.

AC input

Input circuit breaker

Network/Fax/Modem surge protection

Emergency power off function connector (EPO)

USB communication port

RS-232 communication port

SNMP intelligent slot

10

External battery connection (only available for L model)

11

Output terminal

12

Output circuit breaker

13

Input terminal

UPS

IEC Tipo

2-2. Setup the UPS


Step 1: UPS input connection
IEC Tipo

NEMA Tipo

Plug the UPS into a two-pole, three-wire, grounded receptacle only. Avoid using extension cords.


For 208/220/230/240VAC models: The power cord is supplied in the UPS package.
For 110/115/120/127VAC models: The power cord is attached to the UPS. The input plug is a NEMA
5-15P for 1K, 1KL, 1.5K and 1.5KL models, NEMA 5-20P for 2K and 2KL models.

Note: For Low voltage models: Check if the site wiring fault indicator lights up in LCD panel. It will be illuminated
when the UPS is plugged into an improperly wired utility power outlet (Refer to Troubleshooting section).

3K(L) RACK

Step 2: UPS output connection

IEC Tipo

EPSILON 1K /2K/3K On line UPS

NEMA Tipo

For socket-type outputs, there two kinds of outputs: programmable outlets and general outlets. Please
connect non-critical devices to the programmable outlets and critical devices to the general outlets.
During power failure, you may extend the backup time to critical devices by setting shorter backup time
for non-critical devices.

For terminal-type input or outputs, please follow below steps for the wiring configuration:
a) Remove the small cover of the terminal block
b) Suggest using AWG14 or 2.1mm2 power cords. Suggest using WG12-10 or 3.3mm2-5.3mm2 power
cords for NEMA type.
c) Upon completion of the wiring configuration, please check whether the wires are securely affixed.
d) Put the small cover back to the rear panel.

EPSILON 1K /2K/3K On line UPS

Step 6: Turn on the UPS

Step 3: Communication connection


Communication port:

RS-232 port

Intelligent slot

Step 7: Install software


To allow for unattended UPS shutdown/start-up and status monitoring, connect the communication cable one end
to the USB/RS-232 port and the other to the communication port of your PC. With the monitoring software installed,
you can schedule UPS shutdown/start-up and monitor UPS status through PC.
The UPS is equipped with intelligent slot perfect for either SNMP or AS400 card. When installing either SNMP or
AS400 card in the UPS, it will provide advanced communication and monitoring options.
PS. USB port and RS-232 port cant work at the same time.

Step 4: Network connection

For optimal computer system protection, install UPS monitoring software to fully configure UPS
shutdown. You may insert provided CD into CD-ROM to install the monitoring software. If not, please
follow steps below to download and install monitoring software from the internet:




UPS

USB port

Press the ON/Mute button on the front panel for two seconds to power on the UPS.
Note: The battery charges fully during the first five hours of normal operation. Do not expect full battery
run capability during this initial charge period.

1. Go to the website http://www.power-software-download.com


2. Click ViewPower software icon and then choose your required OS to download the software.
3. Follow the on-screen instructions to install the software.
4. When your computer restarts, the monitoring software will appear as an orange plug icon
located in the system tray, near the clock.

Step 8: External battery connection (for long-run models only)

Network/Fax/Phone surge port

Follow the right chart to make external battery connection.

Connect a single modem/phone/fax line into surge-protected IN outlet on the back panel of the UPS unit. Connect
from OUT outlet to the equipment with another modem/fax/phone line cable.

Step 5: Disable and enable EPO function

Keep the pin 1 and pin 2 closed for UPS normal operation. To activate EPO function, cut the wire between pin 1
and pin 2.

Its in closed status for UPS


normal operation.

10

EPSILON 1K /2K/3K On line UPS

EPSILON 1K /2K/3K On line UPS 11

3. Operations

3-2. LCD Panel

UPS

3-1. Button operation

Button
ON/Mute Button

Function
Turn on the UPS: Press and hold ON/Mute button for at least 2 seconds to turn
on the UPS.
Mute the alarm: When the UPS is on battery mode, press and hold this button
for at least 5 seconds to disable or enable the alarm system. But its not applied
to the situations when warnings or errors occur.
Up key: Press this button to display previous selection in UPS setting mode.
Switch to UPS self-test mode: Press and hold ON/Mute button for 5 seconds
to enter UPS self-testing while in AC mode, ECO mode, or converter mode.

Display

Function

Backup time information


Indicates the backup time in pie chart.

OFF/Enter
Button

Select Button

ON/Mute
+ Select Button

Turn off the UPS: Press and hold this button at least 2 seconds to turn off the
UPS in battery mode. UPS will be in standby mode under power normal or
transfer to Bypass mode if the Bypass enable setting by pressing this button.
Confirm selection key: Press this button to confirm selection in UPS setting
mode.

Switch LCD message: Press this button to change the LCD message for input
voltage, input frequency, battery voltage, output voltage and output frequency.
It will return back to default display when pausing for 10 seconds.
Setting mode: Press and hold this button for 5 seconds to enter UPS setting
mode when UPS is in standby mode or bypass mode.
Down key: Press this button to display next selection in UPS setting mode.

Switch to bypass mode: When the main power is normal, press ON/Mute and
Select buttons simultaneously for 5 seconds. Then UPS will enter to bypass
mode. This action will be ineffective when the input voltage is out of acceptable
range.

Indicates the backup time in numbers.


H: hours, M: minute, S: second

Fault information
Indicates that the warning and fault occurs.
Indicates the warning and fault codes, and the codes are listed in
details in 3-5 section.

Mute operation
Indicates that the UPS alarm is disabled.

Output & Battery voltage information


Indicates the output voltage, frequency or battery voltage.
Vac: output voltage, Vdc: battery voltage, Hz: frequency

Load information
Indicates the load level by 0-25%, 26-50%, 51-75%, and 76-100%.

OVER LOAD

SHORT

Indicates overload.
Indicates the load or the UPS output is short circuit.

Programmable outlets information

P1
12

EPSILON 1K /2K/3K On line UPS

Indicates that programmable management outlets are working.

EPSILON 1K /2K/3K On line UPS 13

3-4. LCD display wordings index


Function

Mode operation information

Abbreviation
Indicates the UPS connects to the mains.

ECO

Display content

Meaning

ENA

Enable

DIS

Disable

Indicates the battery is working.

ESC

Escape

Indicates the bypass circuit is working.

HLS

High loss

Indicates the ECO mode is enabled.

LLS

Low loss

BAT

Battery

CF

Converter

EP

EPO

FA

Fan

TP

Temperature

CH

Charger

Indicates the Inverter circuit is working.


Indicates the output is working.
Battery information
Indicates the Battery level by 0-25%, 26-50%, 51-75%,
and 76-100%.

BATT. FAULT

Indicates the battery is fault.

LOW BATT.

Indicates low battery level and low battery voltage.

Input & Battery voltage information

UPS

Display

3-5. UPS Setting

Indicates the input voltage or frequency or battery voltage.


Vac: Input voltage, Vdc: battery voltage, Hz: input frequency

Parameter 1

There are three parameters to set up the UPS.


Parameter 1: Its for program alternatives. There are 9
programs to set up. Refer to below table.
Parameter 2: and parameter 3 are the setting options
or values for each program.

3-3. Audible Alarm

14

Battery Mode

Sounding every 4 seconds

Low Battery

Sounding every second

Overload

Sounding twice every second

Fault

Continuously sounding

Bypass Mode

Sounding every 10 seconds

EPSILON 1K /2K/3K On line UPS

Parameter 2

Parameter 3

EPSILON 1K /2K/3K On line UPS 15

01: Output voltage setting

05: ECO voltage range setting


Setting

Parameter 3: Output voltage


For 208/220/230/240 VAC models, you may choose the following output voltage:
208: presents output voltage is 208Vac
220: presents output voltage is 220Vac
230: presents output voltage is 230Vac
240: presents output voltage is 240Vac
For 110/150/120/127 VAC models, you may choose the following
output voltage:
110: presents output voltage is 110Vac
115: presents output voltage is 115Vac
120: presents output voltage is 120Vac
127: presents output voltage is 127Vac

02: Frequency Converter enable/disable


Interface

Setting

Parameter 2 & 3: Enable or disable converter mode. You may


choose the following two options:
CF ENA: converter mode enable
CF DIS: converter mode disable

03: Output frequency setting


Interface

Setting

Parameter 2 & 3: Output frequency setting.


You may set the initial frequency on battery mode:
BAT 50: presents output frequency is 50Hz
BAT 60: presents output frequency is 60Hz
If converter mode is enabled, you may choose the following
output frequency:
CF 50: presents output frequency is 50Hz
CF 60: presents output frequency is 60Hz

04: ECO enable/disable


Interface

Setting

Parameter 3: Enable or disable ECO function. You may


choose the following two options:
ENA: ECO mode enable
DIS: ECO mode disable

16

EPSILON 1K /2K/3K On line UPS

Interface

Setting

Parameter 2 & 3: Set the acceptable high voltage point and low
voltage point for ECO mode by pressing Down key or Up key.
HLS: High loss voltage in ECO mode in parameter 2.
For 208/220/230/240 VAC models, the setting range in
parameter 3 is from +7V to +24V of the nominal voltage.
For 110/115/120/127 VAC models, the setting range in
parameter 3 is from +3V to +12V of the nominal voltage.

UPS

Interface

LLS: Low loss voltage in ECO mode in parameter 2.


For 208/220/230/240 VAC models, the setting range in
parameter 3 is from -7V to -24V of the nominal voltage.
For 110/115/120/127 VAC models, the setting voltage in
parameter 3 is from -3V to -12V of the nominal voltage.

06: Bypass enable/disable when UPS is off


Interface

Setting

Parameter 3: Enable or disable Bypass function. You may


choose the following two options:
ENA: Bypass enable
DIS: Bypass disable

07: Bypass voltage range setting


Interface

Setting

Parameter 2 & 3: Set the acceptable high voltage point and


acceptable low voltage point for Bypass mode by pressing the
Down key or Up key.
HLS: Bypass high voltage point
For 208/220/230/240 VAC models:
230-264: setting the high voltage point in parameter 3 from
230Vac to 264Vac.
For 110/115/120/127 VAC models:
120-132: setting the high voltage point in parameter 3 from
120Vac to 132Vac
LLS: Bypass low voltage point
For 208/220/230/240 VAC models:
170-220: setting the low voltage point in parameter 3 from
170Vac to 220Vac
For 110/115/120/127 VAC models:
85-115: setting the low voltage point in parameter 3 from
85Vac to 115Vac.

EPSILON 1K /2K/3K On line UPS 17

3-6. Operating Mode Description

Interface

Setting

Online mode

Parameter 3: Enable or disable programmable outlets.


ENA: Programmable outlets enable
DIS: Programmable outlets disable

ECO mode

09: Programmable outlets setting


Interface

Frequency
Converter
mode

Battery mode

Bypass mode

Standby mode

EPSILON 1K /2K/3K On line UPS

When the input voltage is within


acceptable range, UPS will provide pure
and stable AC power to output. The UPS
will also charge the battery at online
mode.

LCD display

Energy saving mode:


When the input voltage is within voltage
regulation range, UPS will bypass voltage
to output for energy saving.

Setting

Parameter 3:
Set up backup time limits for programmable outlets.
0-999: setting the backup time limits in minutes from 0-999 for
programmable outlets which connect to non-critical devices on
battery mode.

18

Description

UPS

Operating mode

08: Programmable outlets enable/disable

When input frequency is within 40 Hz to


70 Hz, the UPS can be set at a constant
output frequency, 50 Hz or 60 Hz. The
UPS will still charge battery under this
mode.

When the input voltage is beyond the


acceptable range or power failure and
alarm is sounding every 4 second, UPS
will backup power from battery.

When input voltage is within acceptable


range but UPS is overload, UPS will enter
bypass mode or bypass mode can be set
by front panel. Alarm is sounding every 10
second.

UPS is powered off and no output supply


power, but still can charge batteries.

EPSILON 1K /2K/3K On line UPS 19

4. Troubleshooting

3-7. Faults Reference Code


Fault code

Icon

Fault event

Fault code

Icon

Bus start fail

01

Inverter voltage Low

13

Bus over

02

Inverter output short

14

SHORT

Bus under

03

Battery voltage too high

27

BATT. FAULT

Bus unbalance

04

Battery voltage too low

28

BATT. FAULT

Inverter soft start fail

11

Over temperature

41

Inverter voltage high

12

Over load

43

OVER LOAD

3-8. Warning indicator


Warning

Icon (flashing)

Low Battery

LOW BATT.

Sounding every second

Overload

OVER LOAD

Sounding twice every second

Battery is not connected

Sounding every second

Over Charge

Sounding every second

Site wiring fault

EPO enable
Fan Failure
Over temperature
Charger failure
Out of bypass voltage range

20

Alarm

EPSILON 1K /2K/3K On line UPS

Sounding every second

EP
FA
CH

If the UPS system does not operate correctly, please solve the problem by using the table below.
Symptom
No indication and alarm even
though the mains is normal.

Check if input power cord


firmly connected to the mains.

The AC input is connected to


the UPS output.

Plug AC input power cord to


AC input correctly.

The icon
and the
warning code flashing
on LCD display and alarm is
sounding every second.

EPO function is activated.

Set the circuit in closed


position to disable EPO
function.

The icon
and
flashing on LCD display and
alarm is sounding every
second.

Line and neutral conductors of UPS


input are reversed.

Rotate mains power socket by


180 and then connect to UPS
system.

The icon
and
flashing on LCD display and
alarm is sounding every
second.

The external or internal battery is


incorrectly connected.

Check if all batteries are


connected well.

Fault code is shown as 27


and the icon BATT. FAULT is lighting
on LCD display and alarm is
continuously sounding.

Battery voltage is too high or the


charger is fault.

Contact your dealer.

Fault code is shown as 28


and the icon BATT. FAULT is lighting
on LCD display and alarm is
continuously sounding.

Battery voltage is too low or the


charger is fault.

Contact your dealer.

UPS is overload

Remove excess loads from UPS


output.

UPS is overloaded. Devices connected to


the UPS are fed directly by the electrical
network via the Bypass.

Remove excess loads from UPS


output.

After repetitive overloads, the UPS is


locked in the Bypass mode. Connected
devices are fed directly by the mains.

Remove excess loads from UPS


output first. Then shut down the
UPS and restart it.

Fault code is shown as 43 and


The icon OVER LOAD is lighting
on LCD display and alarm is
continuously sounding.

The UPS shut down automatically


because of overload at the UPS output.

Remove excess loads from UPS


output and restart it.

Fault code is shown as 14 and


SHORT
the icon
is lighting
on LCD display and alarm is
continuously sounding.

The UPS shut down automatically


because short circuit occurs on the
UPS output.

Check output wiring and if


connected devices are in short
circuit status.

EP

The icon
and OVER LOAD is
flashing on LCD display and
alarm is sounding twice every
second.

Sounding every second

Sounding every second


Sounding every second

Remedy

The AC input power is not


connected well.

Sounding every second

Sounding every second

Possible cause

UPS

Fault event

EPSILON 1K /2K/3K On line UPS 21

Symptom
Fault code is shown as 1, 2,
3, 4, 11, 12, 13 and 41 on
LCD display and alarm is
continuously sounding.

Battery backup time is shorter


than nominal value

Possible cause

Remedy

A UPS internal fault has occurred. There


are two possible results:
1. The load is still supplied, but directly
from AC power via bypass.
2. The load is no longer supplied by
power.

Contact your dealer

Batteries are not fully charged

The icon
and the
warning code flashing
on LCD display and alarm is
sounding every second.

FA

6. Specifications
CAPACITY
INPUT
Voltage
Range

Charge the batteries for at least


5 hours and then check
capacity. If the problem still
persists, consult your dealer.

Batteries defect

Contact your dealer to replace


the battery.

Fan is locked or not working

Check fans and notify dealer.

1000 VA / 800 W
Low Line Transfer

Low Line Comeback


High Line Transfer
High Line Comeback
Frequency Range
Phase
Power Factor

OUTPUT

160 VAC / 140 VAC / 120 VAC / 110 VAC 5 % or 80 VAC / 70 VAC / 60 VAC / 50 VAC 5 %
( based on load percentage 100% - 80 % / 80 % - 70 % / 70 - 60 % / 60 % - 0)
175 VAC 5 % or 85 VAC 5 %
300 VAC 5 % or 150 VAC 5 %
290 VAC 5 % or 145 VAC 5 %
40Hz ~ 70 Hz
Single phase with ground
0.99 @ 220-230 VAC (input voltage)
208/220/230/240VAC or 110/115/120/127 VAC
3% (Batt. Mode)
47 ~ 53 Hz or 57 ~ 63 Hz

Output voltage
AC Voltage Regulation
Frequency Range
(Synchronized Range)
Frequency Range (Batt. Mode)

50 Hz 0.25 Hz or 60Hz 0.3 Hz


100%~110%: audible warning
110%-130%: UPS shuts down in 30 seconds at battery mode or transfers
to bypass mode when the utility is normal.
>130%: UPS shuts down immediately at battery mode or transfer to
bypass mode when the utility is normal.

Overload

5. Storage and Maintenance

Current Crest Ratio

Transfer
Time

The UPS system contains no user-serviceable parts. If the battery service life (3~5 years at 25C ambient
temperature) has been exceeded, the batteries must be replaced. In this case, please contact your dealer.

3:1

3 % THD (Linear Load)

Harmonic Distortion

5-1. Operation

1500 VA / 1200 W 2000 VA / 1600 W 3000 VA / 2400 W

AC Mode to Batt. Mode


Inverter to Bypass

Zero
4 ms (Typical)
Pure Sinewave

Waveform (Batt. Mode)

EFFICIENCY
~ 85%

AC Mode
Battery Mode

~ 88%
~ 83%

BATTERY

Be sure to deliver the spent battery to a recycling facility


or ship it to your dealer in the replacement battery packing
material.

Storage

Before storing, charge the UPS 5 hours. Store the UPS covered and upright in a cool, dry location. During storage,
recharge the battery in accordance with the following table:

Storage Temperature

Recharge Frequency

Charging Duration

-25C - 40C

Every 3 months

1-2 hours

40C - 45C

Every 2 months

1-2 hours

4 % THD (Linear Load)


7 % THD (Non-linear Load)

6 % THD (Non-linear Load)

Standard
Model

Battery Type
Numbers
Recharge Time
Charging Current
Charging Voltage

Long-run
Model

Battery Type & Numbers


Charging Current
Charging Voltage

12 V / 7 AH
3

12 V / 9 AH
12 V / 7 AH
12 V / 9 AH
3
6
6
4 hours recover to 90% capacity (Typical)
1.0 A(max.)
41.0 VDC 1%
82.1 VDC 1%
Depending on the capacity of external batteries
4.0 A or 8.0 A(max.)
41.0 VDC 1%
82.1 VDC 1%

PHYSICAL
Tower
Case

Dimension, D X W X H
Net Weight (kgs)

Rack
Case

Dimension, D X W X H
Net Weight (kgs)

ENVIRONMENT
Operation Humidity
Noise Level

MANAGEMENT

Smart RS-232 or USB


Optional SNMP

421 X 190 X 318 (mm)

397 X 145 X 220 (mm)


13

14

26

16

10

17

13

28

13

580x438x133[3U] (mm)

420x438x88[2U] (mm)
10

29

17

31

17

20-90 % RH @ 0- 40C (non-condensing)


Less than 45dBA @ 1 Meter
Supports Windows 2000/2003/XP/Vista/2008/7, Linux, Unix and MAC
Power management from SNMP manager and web browser

* Derate capacity to 60% of capacity in Frequency converter mode and to 80% when the output voltage is adjusted to 208VAC.

22

EPSILON 1K /2K/3K On line UPS

EPSILON 1K /2K/3K On line UPS 23

Tabla de Contenido
1. Aviso Importante de Seguridad.....................................................................

26

1-1. Transporte......................................................................................................
1-2. Preparacin....................................................................................................
1-3. Instalacin......................................................................................................
1-4. Operacin.......................................................................................................
1-5. Mantenimiento, servicio y fallas......................................................................

26
26
26
27
27

2. Instalacin y ajuste.......................................................................................

28

2-1. Vista trasera del panel....................................................................................


2-2. Ajuste del UPS................................................................................................

28
31

3. Operacin......................................................................................................

34

3-1. Botones de operacin.....................................................................................


3-2. LCD Panel......................................................................................................
3-3. Alarma Audible................................................................................................
3-4. ndice en la pantalla LCD...............................................................................
3-5. Ajustes del UPS..............................................................................................
3-6. Descripcin del modo de Operacin..............................................................
3-7. Referencia de cdigo de fallas.......................................................................
3-8. Indicador de Advertencia................................................................................

34
35
36
37
41
42
42
42

4. Solucin de problemas..................................................................................

5. Almacenamiento y Mantenimiento................................................................

6. Especificaciones............................................................................................

43
44
45

1. Aviso Importante de Seguridad

1-1. Transporte

Por favor transporte el sistema UPS solo en el empaque original para proteger de choques e impactos.

1-2. Preparacin



Puede ocurrir condensacin si el sistema UPS es movido directamente desde un ambiente fro a caliente. El
sistema UPS debe estar absolutamente seco antes de ser instalado. Por favor, espere al menos dos horas
para que el sistema de UPS para aclimatarse al medio ambiente.

No instale el sistema UPS cerca a agua o ambientes hmedos.

No instale el sistema UPS donde pueda estar expuesto a la luz directa del sol o cerca de calor.

No bloquee los orificios de ventilacin del UPS.

1-3. Instalacin

No conecte aplicaciones o dispositivos los cuales puedan sobrecargar el sistema UPS (e.g. impresora lser)
a la salida del UPS.
Ubique los cables de una forma adecuada que nadie pueda pisar o tropezar con ellos.

No conecte aplicaciones domesticas como secador de pelo a las tomas de salida del UPS.

El UPS puede ser operado por cualquier individuo sin previa experiencia.

Conecte el sistema UPS slo a una salida puesta a tierra que debe ser fcilmente accesible y cerca del
sistema de UPS.

Por favor, use slo cable de red certificado (por ejemplo, el cable de red de su ordenador) para conectar el
sistema UPS a la toma de corriente de un edificio.

Por favor use solo cable certificado para conectar las cargas al sistema UPS.

Cuando instale el equipo, asegrese que la suma de corrientes de fuga del UPS no excedan 3.5mA.

26

EPSILON 1K /2K/3K On line UPS

No desconecte el cable principal en el sistema UPS o los cables de salida del edificio durante la
operacin, ello anulara la proteccin de tierra del UPS y de todas las cargas conectadas.
El sistema UPS cuenta con su propia fuente de corriente interna (bateras). Las tomas de salida
del UPS o bloque de salida de los terminales puede ser elctricamente activo, incluso si el
sistema UPS no est conectado a la toma de cableado del edificio.

Para desconectar completamente el sistema de UPS, presione primero el OFF / Enter para
desconectar la red elctrica.

Prevenga entrada de fluidos u objetos extraos dentro del sistema UPS.

UPS

Por favor cumpla estrictamente con todas las advertencias e instrucciones de operacin de este manual. Guarde
este manual apropiadamente y lea cuidadosamente las siguientes instrucciones antes de instalar la unidad. No
opere esta unidad antes de leer cuidadosamente atravs de toda la informacin de seguridad e instrucciones de
operacin.

1-4. Operacin

1-5. Mantenimiento, servicio y fallas



El sistema UPS opera con voltajes peligrosos. Reparaciones solo pueden llevarse acabo por personal de
mantenimiento calificado.

Precaucin Riesgo de descarga elctrica. Incluso despus de que la unidad est desconectada de la red
elctrica (enchufe del cableado del edificio), componentes internos del sistema UPS an est conectado a la
batera y elctricamente activo y peligroso.

Antes de realizar cualquier tipo de servicio y / o mantenimiento, desconecte las bateras y compruebe que no
hay corriente presente y no existe tensin peligrosa en los terminales del condensador de alta capacidad
como BUS-condensadores.

Slo las personas que estn debidamente familiarizados con bateras y con las medidas necesarias de
precaucin puede reemplazar las bateras y supervisar las operaciones. Las personas no autorizadas deben
mantenerse alejados de las bateras.

Precaucin Riesgo de descarga elctrica. El circuito de la batera no est aislado de la tensin de entrada.
Tensin peligrosa puede ocurrir entre los terminales de la batera y el suelo. Antes de tocar, por favor
verifique que no haya tensin!


Bateras podra causar descargas elctricas y tienen una alta corriente de corto circuito. Por favor, tome las

medidas cautelares indicadas a continuacin y las dems medidas necesarias cuando se trabaja con las

bateras:

Retrese relojes de pulsera, anillos y otros objetos.

Utilizar slo herramientas con mangos y manija aisladas.

Cuando cargue las bateras, instale el mismo nmero y tipo de bateras.

No intente desechar las bateras por la quema de ellos. Esto podra provocar una explosin de la batera.
No abrir o destruir las bateras. Escape de electrolitos puede causar lesiones en la piel y los ojos.
Puede ser txico.
Por favor reemplace el fusible solo con el mismo tipo y amperaje a fin de evitar riesgos de incendio.
No desmonte el sistema UPS.

EPSILON 1K /2K/3K On line UPS 27

2. Instalacin y ajuste

UPS

NOTE: Antes de instalar, por favor inspeccione la unidad. Asegrese que no hay nada daado dentro del
empaque. Por favor mantenga el empaque original en un lugar seguro para futuros usos.

2K (L) TORRE

NOTA: Hay dos tipos diferentes de UPS online: Modelo estndar y larga duracin. Por favor refirase a la
siguiente tabla.

Modelo
1K
2K
3K

Tipo
Estndar

Modelo
1KL
2KL
3KL

Tipo
Larga
duracin

2-1. Vista trasera del panel


1K (L) TORRE

Tipo IEC

28

EPSILON 1K /2K/3K On line UPS

Tipo IEC

Tipo NEMA

Tipo IEC

Tipo NEMA

3K (L) TORRE

Tipo NEMA

EPSILON 1K /2K/3K On line UPS 29

1K(L) RACK

Tipo NEMA

Salidas Programables: Conexin para cargas no crticas.

Receptculos de salida: Conexin para cargas de misin crtica.

Entrada AC

Interruptor de circuito de entrada

Proteccion de picos para terminal de Red/Fax/Modem

Conector de function apagado de emergencia (EPO)

Puerto de comunicacin USB

RS-232 puerto de comunicaciones inteligentes ranura SNMP

Conexin Batera Externa (Solo habilitada para modelo L)

10

Terminal de Salida

11

Interruptor de circuito de salida

12

Terminal de entrada

UPS

Tipo IEC

2K(L) RACK

2-2. Ajustes del UPS


Paso 1: Conexin de entrada del UPS

Conecte el UPS conector de tres hilos, dos polos y receptculo conectado a tierra. Evite el uso de cables de
extensin
Tipo IEC

Tipo NEMA

Para modelos 208/220/230/240VAC: El cable de alimentacin esta incluido en el empaque del UPS.
Para modelos 110/115/120/127VAC: El cable de alimentacin esta conectado al UPS. El conector de
entrada es un NEMA 5-15P para modelos 1K y 1KL, NEMA 5-20P para modelos 2K y 2KL.

Nota: Para modelos de bajo voltaje: Revise si el indicador de falla en cableado del sitio esta indicando falla en
el panel frontal. Este se iluminara cuando el UPS esta conectado no apropiadamente (Refirase a la seccin de
Gua de Fallas).

3K(L) RACK

Paso 2: Conexin de salida del UPS

Tipo IEC

30

EPSILON 1K /2K/3K On line UPS

Tipo NEMA

Para las salidas tipo socket, hay dos clases de salidas: salidas programables y salidas generales. Por
favor conecte dispositivos no crticos a las salidas programables y dispositivos crticas a las salidas
generales. Durante una falla de alimentacin de entrada, usted puede extender el tiempo de respaldo a
dispositivos crticos, acortando el tiempo de respaldo para dispositivos no crticos.
Para terminal tipo entrada o salida, por favor siga los pasos siguientes para configuracin del cableado:
a) Remueva la pequea tapa del bloque de terminales
b) Sugerido usar cable AWG14 o 2.1mm2 para el cable de alimentacin. Sugerido usar cable WG12-10
o 3.3mm2-5.3mm2 para el cable de alimentacin tipo NEMA.
c) Una vez completada la configuracin del cableado, por favor compruebe que los cables estn firme
mente fijados.
d) Ponga la pequea tapa en el panel trasero.

EPSILON 1K /2K/3K On line UPS 31

Paso 6: Encienda el UPS

Paso 3: Conexin de comunicacin


Puerto de Comunicacin:
Puerto RS-232

Ranura Inteligente

Para permitir la vigilancia del apagado y arranque del UPS y monitoreo del estatus, conecte un el cable de
comunicacin al Puerto USB/RS-232 y otro al Puerto de comunicacin de su PC. Con el software de monitoreo
instalado, usted puede programar el horario de encendido / apagado y monitoreo del UPS atravs de su PC.
El UPS esta equipado con una ranura perfecta inteligente para ambas tarjetas SNMP o AS400. Cuando instale la
tarjeta SNMP o AS400 en el UPS, provee avanzadas opciones de comunicacin y monitoreo.
PS. El Puerto USB y RS-232 no pueden trabajar al mismo tiempo.

Paso 4: Conexin de RED.


Red/Fax/Puerto de proteccin de picos

Nota: Las bateras quedaran cargadas totalmente durante las primeras cinco horas de
operacin normal. No espere respaldo de la capacidad total de la batera durante el periodo
de carga inicial.

UPS

Puerto USB

Presione el botn de ON/Mute ubicado en el panel frontal por dos segundos para encender el UPS.

Paso 7: Instale software


Para optima proteccin del sistema de su computador, instale software de monitoreo del UPS, para
total configuracin de apagado. Instale el CD provedo dentro de la unidad de CD-ROM para instalar el
software de monitoreo. Si no, por favor siga los pasos siguientes para descargar e instalar el software
de monitoreo desde el internet:




1. Ir a la pgina Web http://www.power-software-download.com


2. Presione el icono de ViewPower software y escoja su OS requerido para descargar el software.
3. Siga las instrucciones del software en la pantalla.
4. Cuando restaure su computador, el software de monitoreo aparecer con un icono de conector
naranja localizado en la barra del sistema cerca del reloj.

PASO 8: Conector Externo de Bateras


(Solo para los modelos de larga duracin)
Conecte la lnea de un modem sencillo/telfono/fax en el protector de picos de entrada IN ubicado en el panel
trasero del UPS. Conecte a la salida OUT el equipo con otro cable de lnea para modem sencillo/telfono/fax.

Paso 5: Habilitar y deshabilitar la funcin de EPO

Mantenga el pin 1 y el pin 2 cerrado para operacin normal del UPS. Para activar la funcin de EPO, abra el
cable entre pin 1 y pin 2.

Esta en estado cerrado,


durante el funcionamiento
normal del UPS

32

EPSILON 1K /2K/3K On line UPS

EPSILON 1K /2K/3K On line UPS 33

3. Operaciones

3-2. LCD Panel

UPS

3-1. Botn de operacin

Botn
ON/Mute Botn

OFF/Enter
Botn

Select Botn

ON/Mute
+ Select Botn

Funcin
Encienda el UPS: Presione el botn de ON/Mute por lo menos 2 segundos
para que encienda el UPS.
Alarma de Silencio (Mute): Cuando el UPS est en modo batera, presione
este botn y espere por lo menos 5 segundos para deshabilitar o habilitar el
sistema de alarma. Esto no se aplica a situaciones de advertencia o cuando
ocurre un error.
Tecla de subir (Up key): Presione este botn par ver la pantalla anterior en el
modo de ajustes del UPS.
Cambiar el UPS a modo de auto-prueba: Presione el botn ON/Mute y
espere por 5 segundos para iniciar el autodiagnstico mientras el UPS esta en
modo AC, modo ECO, o modo Inversor.
Apague el UPS: Presione este botn y espere por lo menos 2 segundos para
apagar el UPS en modo de batera. El UPS debe estar en modo de espera
con la energa normal o transferir a modo de Bypass en caso de estar
habilitado.
Confirmar tecla de seleccin: Presione este botn para confirmar lo
seleccionado en modo ajustes del UPS.
Cambiar mensaje en LCD: Presione este botn para cambiar el mensaje de
la pantalla para voltaje de entrada, frecuencia de entrada, voltaje de batera,
salida de voltaje y salida de frecuencia. Este regresara por defecto al display
inicial cuando pasen 10 segundos.
Modo Ajustes: Presione este botn y espere 5 segundos para entrar al modo
de ajustes del UPS cuando el UPS esta en modo de stanbye o bypass.
Tecla de bajar (Down key): Presione este botn para seleccionar la siguiente
pantalla en el modo de ajustes del UPS.
Cambiar a modo de bypass: Cuando el suministro de energa es normal,
presione ON/Mute y seleccione los botones simultneamente por 5
segundos. Luego el UPS entrara en modo de bypass. Esta accin no ser
eficiente cuando los rangos de entrada de voltaje no son aceptables.

Mostrar

Funcin

Informacin de tiempo de respaldo


Indicador de tiempo de respaldo en el grafico circular.
Indicador de tiempo de respaldo en nmeros.
H: horas, M: minutos, S: segundos

Informacin de Falla
Indica advertencia y ocurri una falla.
Indica advertencia y cdigo de falla, el detalle de los cdigos esta
listado en la seccin 3-5.

Operacin de Silencio
Indica que la alarma del UPS est deshabilitada.

Informacin de Voltaje de Salida y Batera


Indica el voltaje de salida, frecuencia o voltaje de batera.
Vac: Voltaje de salida, Vdc: Voltaje de batera, Hz: frecuencia

Informacin de Carga
Indica el nivel de carga de 0-25%, 26-50%, 51-75%, y 76-100%.

OVER LOAD

SHORT

Indica sobrecarga.
Indica la carga o el circuito de salida del UPS est en corto circuito.

Informacin de salidas Programables

P1
34

EPSILON 1K /2K/3K On line UPS

Indica que la administracin de salidas programables est trabajando.

EPSILON 1K /2K/3K On line UPS 35

3-4. Indice Pantalla LCD


Funcin

Informacin del Modo de operacin

Abreviacin

Indica que el UPS est conectado a la red elctrica.

ECO

Contenido de la pantalla

Significado

ENA

Habilitado

DIS

Deshabilitado

Indica que la batera est trabajando.

ESC

Escape

Indica que el circuito de bypass est trabajando

HLS

Alta perdida

Indica que el modo ECO est habilitado.

LLS

Baja perdida

BAT

Batera

CF

Conversor

EP

EPO

FA

Ventilador

TP

Temperatura

CH

Cargador

Indica que el circuito inversor est trabajando.


Indica la salida est trabajando.
Informacin de batera
Indica el nivel de batera de 0-25%, 26-50%, 51-75%, y
76-100%.

BATT. FAULT

Indica que la batera est en falla.

LOW BATT.

Indica bajo nivel de batera y bajo voltaje de batera.

Informacin de voltaje de entrada & batera

UPS

Mostrar

3-5. Ajustes del UPS

Indica el voltaje de entrada o frecuencia o voltaje de batera.


Vac: Voltaje de entrada, Vdc: Voltaje de batera, Hz: Frecuencia
de entrada

Parmetro 1

Existen 3 parmetros para configurar el UPS.


Parmetro 1: Es para programas alternativos.
Existen 9 programas para ajuste del UPS. Refirase
a la siguiente tabla.

3-3. Alarma Audible

36

Modo Batera

Pita cada 4 Segundo

Baja Batera

Pita cada Segundo

Sobrecarga

Pita dos veces cada Segundo

Falla

Pita Continuamente

Modo Bypass

Pita cada 10 Segundos

EPSILON 1K /2K/3K On line UPS

Parmetro 2 y parmetro 3: Son las opciones de


ajuste o valores para cada programa.

Parmetro 2

Parmetro 3

EPSILON 1K /2K/3K On line UPS 37

01: Ajustes de salida de voltaje

05: ECO Ajuste de rango de voltaje


Ajuste

Parmetro 3: Voltaje de salida


Para modelos 208/220/230/240 VAC, usted debe escoger las
siguientes salidas de voltaje:
208: Voltaje de salida presente es 208Vac
220: Voltaje de salida presente es 220Vac
230: Voltaje de salida presente es 230Vac
240: Voltaje de salida presente es 240Vac
Para modelos 110/150/120/127 VAC, usted puede elegir las
siguientes salidas de voltaje:
110: Voltaje de salida presente es 110Vac
115: Voltaje de salida presente es 115Vac
120: Voltaje de salida presente es 120Vac
127: Voltaje de salida presente es 127Vac

02: Convertidor de Frecuencia habilitado/deshabilitado


Interfaz

Ajuste

Parmetro 2 & 3: Habilitado o deshabilita modo conversor.


Puede elegir dos opciones:
CF ENA: modo conversor habilitado
CF DIS: modo conversor deshabilitado

Interfaz

Ajuste

Parmetro 2 & 3: Ajuste el punto del nivel de voltaje alto y bajo


aceptable para el modo ECO presionando la tecla de bajar (Down)
o subir (Up).
HLS: Alto perdida de voltaje en el modo ECO en el parmetro 2.
Para los modelos 208/220/230/240 VAC, el ajuste del rango en el
parmetro 3 es desde +7V a +24V de voltaje nominal.
Para modelos 110/115/120/127 VAC, el ajuste del rango en el
parmetro 3 es desde +3V a +12V del voltaje nominal.
LLS: Perdida de bajo voltaje en modo ECO en el parmetro 2.
Para modelos 208/220/230/240 VAC, el ajuste del rango en el
parmetro 3 es desde -7V a -24V del voltaje nominal.
Para modelos 110/115/120/127 VAC, el ajuste del voltaje en
parmetro 3 es de -3V a -12V del voltaje nominal.

UPS

Interfaz

06: Bypass Habilitado/deshabilitado cuando el UPS esta apagado


Interfaz

Ajuste

Parmetro 3: Habilitar o deshabilitar la funcin de Bypass.


Usted puede elegir las siguientes dos opciones:
ENA: Bypass Habilitado
DIS: Bypass Deshabilitado

03: Ajustes de Frecuencia de salida


Interfaz

Ajuste

Parmetro 2 & 3: Ajuste de frecuencia de salida.


Usted puede ajustar la frecuencia inicial en modo batera:
BAT 50: Salida de frecuencia presente es 50Hz
BAT 60: Salida de frecuencia presente es 60Hz
Si el modo conversor es habilitado, usted puede elegir la
siguiente frecuencia:
CF 50: Salida de frecuencia presente es 50Hz
CF 60: Salida de frecuencia presente es 60Hz

04: ECO Habilitado/Deshabilitado


Interfaz

Ajuste

Parmetro 3: Para habilitar o deshabilitar la funcin ECO.


Usted puede elegir las siguiente opciones:
ENA: ECO Modo Habilitado
DIS : ECO Modo Deshabilitado

38

EPSILON 1K /2K/3K On line UPS

07: Bypass ajuste del rango de voltaje


Interfaz

Ajuste

Parmetro 2 & 3: Ajuste el punto de alto voltaje y bajo voltaje


aceptable para modo de Bypass presionando la tecla bajar
(Down) o Subir (Up).
HLS: Punto de alto voltaje
Para modelos 208/220/230/240 VAC:
230-264: ajuste el punto de alto voltaje en el parmetro 3 de
230Vac a 264Vac.
Para modelos 110/115/120/127 VAC:
120-132: ajuste el punto de alto voltaje en el parmetro 3 de
120Vac a 132Vac
LLS: Punto de bajo voltaje
Para modelos 208/220/230/240 VAC:
170-220: ajuste el punto de bajo voltaje en parmetro 3 de
170Vac a 220Vac
Para modelos 110/115/120/127 VAC:
85-115: ajuste el punto de bajo voltaje en parmetro 3 de 85Vac
a 115Vac.

EPSILON 1K /2K/3K On line UPS 39

3-6. Operating Mode Description

Interface

Ajuste

Modo Online

Parmetro 3: Salidas programables habilitado o deshabilitado.


ENA: Salidas programables habilitado
DIS: Salidas programables deshabilitar

Modo ECO

09: : Ajuste de salidas programables


Interface

Modo de
conversor de
Frecuencia

Modo Batera

Modo Bypass

Modo Standby

EPSILON 1K /2K/3K On line UPS

Cuando la entrada de voltaje est dentro


del rango aceptable, UPS provee energa
AC pura y estable. El UPS tambin
cargar la batera en el modo online.

Pantalla LCD

Modo de ahorro de energa:


Cuando la entrada de voltaje esta
dentro del voltaje regulado, UPS pasara a
bypass proporcionando voltaje a la salida
para ahorro de energa.

Ajuste

Parmetro 3: Ajuste los lmites del tiempo de respaldo par alas


salidas programables.
0-999: Ajuste el lmite del tiempo de respaldo en minutos de
0-999 para las salidas programables a la cual conecta los
dispositivos de carga no critica en modo bacteria.

40

Descripcion

UPS

Modo Operacin

08: Salidas Programables habilitadas /deshabilitadas

Cuando la entrada de frecuencia esta


dentro 40 Hz a 70 Hz, el UPS puede ser
ajustado a una constante frecuencia de
salida, 50 Hz o 60 Hz. El UPS continuara
cargando la batera de este modo.

Cuando la entrada de voltaje Cuando el


voltaje de entrada est fuera del rango
aceptable o falta de energa elctrica y la
alarma est sonando cada 4 segundo 4,
UPS soportara con el respaldo de energa
en batera.
Cuando la entrada est dentro del rango
aceptable pero esta en sobrecarga, el
UPS entrara en modo de Bypass o puede
ser ajustado manualmente desde el
panel. La Alarma sonara cada 10
segundos.

UPS est apagada y no hay energa de


salida, pero an continua cargando las
bateras.

EPSILON 1K /2K/3K On line UPS 41

4. Solucin de Problemas

3-7. Referencia de cdigo de fallas


Cdigo de falla Icono

Evento de falla

Cdigo falla

Icono

Bus comienza a fallar

01

Bajo Voltaje en Inversor

13

Bus por encima

02

Salida en corto Inversor

14

SHORT

Bus por debajo

03

Voltaje de batera alto

27

BATT. FAULT

Bus desbalanceado

04

Voltaje de batera bajo

28

BATT. FAULT

Inversor en falla

11

Sobre temperature

41

Inversor con voltaje alto

12

Sobre carga

43

OVER LOAD

3-8. Indicador de Advertencia


Advertencia

Icon (Parpadeando)

Batera baja

LOW BATT.

Pitando cada Segundo

Sobrecarga

OVER LOAD

Pitando dos veces cada segundo

Batera desconectada

Pitando cada Segundo

Sobrecarga

Pitando cada segundo

Sitio con falla de cableado

EPO Habilitado
Ventilador Fallo
Sobre temperature
Falla de carga
Fuera del Rango de voltaje
en bypass

42

Alarma

EPSILON 1K /2K/3K On line UPS

Pitando cada segundo

EP
FA
CH

Si el sistema no opera correctamente, por favor resuelva el problema usando la tabla siguiente
Sintomas

Revise el cable de entrada si est


bien conectado a la red elctrica.

La entrada AC est conectada


ala salida del UPS.

Conecte el cable de entrada AC


a la entrada AC correctamente.

El icono
y
el
cdigo de advertencia parpadea en la pantalla y la alarma
suena cada segundo.

La funcin de EPO est activada.

Ajuste el circuito en la posicin


de cerrado para deshabilitar la
funcin de EPO.

El icono
y
parpadea
en la pantalla y la alarma
suena cada segundo.

Los conductores de lnea y neutro de la


entrada del UPS estn invertidos.

Rotar la toma de corriente de


alimentacin a 180 y luego
conectarse al sistema de UPS.

El icono
y
parpadean en la pantalla y la
alarma suena cada segundo.

La batera externa o interna est


incorrectamente conectada.

Revise si todas las bateras


estn bien conectadas.

Cdigo de falla 27 y el icono


est
iluminando en
BATT. FAULT
la pantalla y el sonido de la
alarma es continuo.

Voltaje del cargador es tambin alto o


el cargador est fallando.

Contacte su distribuidor.

Cdigo de falla 28 y el icono


BATT. FAULT
est iluminando en
la pantalla y el sonido de la
alarma es continuo.

Voltaje del cargador es tambin bajo o


el cargador est fallando.

Contacte su distribuidor.

UPS est sobrecargada

Remueva el exceso de carga a


la salida del UPS.

UPS est sobrecargada. Dispositivos conectados al UPS estn siendo directamente


alimentados por la red elctrica va bypass.

Remueva el exceso de carga de


la salida del UPS.

Despus de repetitivas sobrecargas, el


UPS se bloquea, en el modo de Bypass.
Conecte los dispositivos para que sean
alimentados directamente.

Remueva el exceso de carga


desde la salida del UPS. Luego
apague el UPS y resturelo.

Cdigo de falla 43 y el icono


OVER LOAD
est iluminando en
la pantalla y la alarma suena
continuamente.

El UPS se apaga automticamente


porque la salida del UPS est
sobrecargada.

Remueva el exceso de carga de la


salida del UPS y resturelo.

Cdigo de falla 14 y icono


SHORT
esta iluminando en
la pantalla y la alarma esta
pitando continuamente.

El UPS se paga automticamente


porque ocurri un corto circuito a la
salida del UPS.

Revise los cables de salida y el


estado de los dispositivos
conectados que no estn en corto.

EP

El icono
y OVER LOAD
est iluminando en la pantalla
y la alarma suena dos veces
cada segundo.

Pitando cada segundo

Pitando cada segundo


Pitando cada segundo

Solucin

La entrada AC no est bien


conectada.

No hay indicacin y alarma


a pesar de que la red es
normal.

Pitando cada segundo

Pitando cada segundo

Posible causa

UPS

Evento de error

EPSILON 1K /2K/3K On line UPS 43

Sintomas

Posible causa

Cdigo de falla mostrado


como 1, 2, 3, 4, 11, 12, 13
y 41 en la pantalla y alarma
pitando constantemente.

El tiempo de batera es ms
corto que el valor nominal.

El icono
y el cdigo
de advertencia
parpadeando en la pantalla
y la alarma pitando cada
segundo.

FA

Una falla interna ha ocurrido en el UPS.


Aqu hay dos posibles razones:
1. La carga est an funcionando,
pero directamente desde la red AC va
bypass.

Bateras no estn cargadas totalmente

Solucin
Contacte su distribuidor

6. Especificaciones
CAPACIDAD*
ENTRADA
Rango
Voltaje

Cargar las bateras por lo


menos 5 horas y luego revise
la capacidad. Si el problema
aun persiste, consulte su
distribuidor.

Defecto de Bateras

Contacte su distribuidor para


reemplace las bateras.

Ventilador est bloqueado o no trabaja.

Revise los ventiladores y


notifique su distribuidor!

Transferencia Linea Baja

Regreso de Linea Baja


Transferencia Linea alta
Regreso de Linea alta
Rango de frecuencia
Fase
Factor de potencia

SALIDA

1000 VA / 800 W

160 VAC / 140 VAC / 120 VAC / 110 VAC 5 % or 80 VAC / 70 VAC / 60 VAC / 50 VAC 5 %
( basado en porcentaje de Carga 100% - 80 % / 80 % - 70 % / 70 - 60 % / 60 % - 0)
175 VAC 5 % or 85 VAC 5 %
300 VAC 5 % or 150 VAC 5 %
290 VAC 5 % or 145 VAC 5 %
40Hz ~ 70 Hz
Fase monofsica con tierra
0.99 @ 220-230 VAC (input voltage)
208/220/230/240VAC or 110/115/120/127 VAC
3% (Modo Batera)
47 ~ 53 Hz or 57 ~ 63 Hz

Voltaje de salida
Regulacin de voltaje AC
Rango de Frecuencia
(Rango sincronizado)
Rango de Frecuencia (Modo Batera)

50 Hz 0.25 Hz or 60Hz 0.3 Hz


1100%~110%: advertencia audible
110%-130%: UPS se apagara en 30 segundos en modo batera o
transfiere a modo de bypass cuando el voltaje de red elctrica es normal.
>130%: UPS se apagar automticamente en modo batera o transfiere a
modo de bypass cuando la red elctrica es normal.

Sobre carga

5. Almacenamiento y Mantenimiento

Corriente de cresta
Distorsin Armnica

5-1. Operacin

Tiempo
transferencia

El UPS no contiene partes reparables por el usuario. Si la vida til de las bateras (3~5 aos a 25C a temperatura
ambiente) ha sido excedida, las bateras deben ser reemplazadas. En este caso, por favor contacte a su
distribuidor.

1500 VA / 1200 W 2000 VA / 1600 W 3000 VA / 2400 W

3:1

3 % THD (Carga lineal)

Modo AC A Batera
Inversor a Bypass

Almacenar

Antes de almacenar, cargue el UPS 5 horas. Almacene el UPS cubierto en posicin vertical en lugar fresco y
seco. Durante el almacenamiento, recargue la batera de acuerdo a la siguiente tabla:

Temperatura almacenaje

Frecuencia de recarga

Duracin de la carga-

25C - 40C

Cada 3 meses

1-2 horas

40C - 45C

Cada 2 meses

1-2 horas

4 % THD (Carga lineal)


7 % THD (Carga no lineal)

Zero
4 ms (Tpico)
Onda seno pura

Waveform (Batt. Mode)

EFICIENCIA
~ 85%

Modo AC
Modo Batera

~ 88%
~ 83%

BATERIA

No olvide enviar la batera a un centro de reciclaje o a


su distribuidor en el material de embalaje de la batera.

6 % THD (Carga no lineal)

Modelo
Estandar

Tipo Batera
Nmero
Tiempo de recarga
Corriente de carga
Voltaje de carga

Modelo
de larga
duracin

Tipo de Batera & Nmero


Corriente de carga
Voltaje de carga

12 V / 7 AH
3

12 V / 9 AH
12 V / 7 AH
12 V / 9 AH
3
6
6
4 horas recuperado al 90% capacidad (Tpica)
1.0 A(max.)
41.0 VDC 1%
82.1 VDC 1%
Dependiendo de la capacidad de las bateras externas
4.0 A or 8.0 A(max.)
41.0 VDC 1%
82.1 VDC 1%

FISICAS
Tipo
Torre

Dimension, D X W X H
Peso Neto (kgs)

Tipo
Rack

Dimension, D X W X H
Peso Neto (kgs)

AMBIENTE
Operacin Humedad
Nivel de Ruido

SOFTWARE

Puerto Inteligente RS-232 o USB


Opcional SNMP

421 X 190 X 318 (mm)

397 X 145 X 220 (mm)


13

14

26

16

10

17

13

28

13

580x438x133[3U] (mm)

420x438x88[2U] (mm)
10

29

17

31

17

20-90 % RH @ 0- 40C (non-condensing)


Menos que 45dBA a 1 Metro
Soporta Windows 2000/2003/XP/Vista/2008/7, Linux, Unix and MAC
Administracin de energa desde SNMP y navegador Web

* Derateado capacidad a 60% en modo conversor de frecuencia y a 80% cuando el voltaje de salida es ajustado a 208VAC.

44

EPSILON 1K /2K/3K On line UPS

EPSILON 1K /2K/3K On line UPS 45

Manual Usuario

UPS EPSILON

On-line Doble Conversin 1K/2K/3K

Sistema de Alimentacin Ininterrumpido

www.qbex.com

You might also like