Important
Always monitor tank fluid level as you are producing smoke. Running a AirTrace with no fluid can
permanently damage the unit.
If you experience low output, pump noise or no output at all, remove the battery immediately. Check fluid
level and re-charge the battery. When the liquid tank is full and the battery is charged, plug the battery in
and press the button on the handle.
If the machine is still not working and you are unable to determine the cause of the problem, do not open
the case. There are no user serviceable parts inside. Return the machine to a Concept dealer for service.
Performance Notes
All smoke machines develop condensation around the output nozzle.
The AirTrace may produce small puffs of smoke occasionally during operation and for a minute or so after
being turned off. This is normal and is not indicative of a defect.
After continuous operation, the case of the AirTrace will become warm, especially at the front of the
machine. Take care in handling the machine during and shortly after fogging. Only carry the AirTrace by the
handle and let the machine cool down before packing it in a carry case.
Extension Tube
If fitting the extension tube for precise smoke placement, ensure that the breather holes in the tube are at
the end closest to the machine. They are designed to draw air into the vapour stream and help the
formation of smoke.
A small amount of deposition will occur over time in the extension tube due to the restriction of the smoke
particles. Always clean the extension tube after use.
Optional Power Adaptor
When desired the AirTrace can be powered by an optional power adaptor which plugs into a standard
electrical outlet. The adaptor connects to a dummy battery which plugs into the battery slot on the
AirTrace. This allows for extended operation of the AirTrace
Optional Remote Control Operation
An optional Wireless Remote Control is available on request:
If using the Radio Remote always ensure the battery is fully
charged or use a mains adaptor with dummy battery. Always
ensure the Air Trace has sufficient smoke chemical.
Adjust the Slide Switch using a miniature screw driver towards the
reservoir as indicated by Yellow Arrow (this is the momentary
smoke position)
Preparation
Connect receiver to Air Trace as shown
To Make Smoke
Press the A button on the key fob to make smoke
To Stop Producing
Press the B button on the key fob. Smoke will stop within 10 secs.
Remove the receiver from the Air Trace when not in use.
If you wish to maintain momentary switching (so the smoke
generator will only produce smoke when the smoke button on the
handle is depressed) leave the Slide Switch in the position detailed
above.