Cqi 9 Errata AIAG
Cqi 9 Errata AIAG
Cqi 9 Errata AIAG
Page
Item #
17
3.5.5
17
3.5.6
43
A1.9
48
B1.7
54
C1.3
58
D1.2
62
E1.8
65
E4.2
Explanation
Temperature controlling instruments purchased prior to 1 year after
the release of AMS 2750D are exempt of 3.2.5.1 and 3.2.5.2.
One point sensor input is acceptable.
Sensitivity checks during calibration are not required.
Control Instrument
Part or Raw
Material
1500
1501
Lead Wire
Chart Recorder
Test Instrument
Furnace
Work Zone
B
Note: The test sensor can be a
resident thermocouple, refer to
AMS 2750 D section 3.4.4.2.1
900 C
(1652oF)
TEST
INSTRUMENT
TEMPERATURE
INDICATION
(B)
o
901.5 C
(1655oF)
TEST SENSOR
CORRECTION
FACTOR
(C)
o
-0.5 C
(-1.0oF)
TEST
INSTRUMENT
CORRECTION
FACTOR
(D)
o
+0.1 C
(+0.2oF)
TRUE TEST
TEMPERATURE
SAT
DIFFERENCE
(E)=(B)+(C)+(D)
(A) (E)
-1.1oC
(-2.2oF)
901.1 C
(1654.2oF)
Example of Comparative
Method
Control Instrument
Control Sensor
Over-Temp Sensor
Part or Raw
Material
1500
1501
Chart Recorder
Furnace
Work Zone
Over Temp
Protection
Furnace Wall
Any actions to correct a failing reading or validate a test result shall be documented.
Control Sensors (CS) failing to meet the requirements of SAT method 1 shall be changed. A
new TUS is not required unless the position of the control sensor changes. If new
thermocouple(s) are required in Test method 2, a new relationship must be established.
Base metal sensors (e.g. Type K, N, J, E) thermocouples shall be changed when needed
or annually at a minimum for equipment operating at or above 760C (1400F).
Base metal sensors (e.g. Type K, N, J, E) thermocouples shall be changed when needed
or every two years at a minimum for equipment operating below 760C (1400F).
Noble metal sensors (e.g. Type R and S) thermocouples shall be changed when needed
or every two years at a minimum for equipment operating at or above 760C (1400F).
Note: A new TUS is not required for any thermocouple replacement unless the position
of the control sensor(CS) is changed (CS)
Section 3.5.6
o
o
o
o
o
o
o
o
o
Minimum and maximum temperature ranges shall be tested per AMS 2750D.
Exception: If the operating range of the Qualified Work Zone is equal to or less
than 170oC (306oF) then only one temperature is required to be tested. The
temperature shall be within the operating range of the Qualified Work Zone.
Section 3.5.8
Furnace Parameters During TUS
Section 3.5.9
Furnace Temperature at Insertion of TUS Sensors (Thermocouples)
Section 3.5.10 Load Condition
Section 3.5.11 Furnace Atmosphere During TUS
Section 3.5.13 Batch Furnaces, Salt Baths, Controlled Temperature Liquid Baths, and
Fluidized Bed Furnaces EXCEPT:
o
o
Minimum and maximum temperature ranges shall be tested per AMS 2750D.
Exception: If the operating range of the Qualified Work Zone is equal to or less
than 170oC (306oF) then only one temperature is required to be tested. The
temperature shall be within the operating range of the Qualified Work Zone.
3.5.13.3.2: CQI-9 requires that data from the TUS sensors is automatically
recorded.